0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FBK04A05L1ZB

FBK04A05L1ZB

  • 厂商:

    PANASONIC

  • 封装:

  • 描述:

    FBK04A05L1ZB - Locked rotor protection circuits Automatically restarts in a few seconds Reverse volt...

  • 数据手册
  • 价格&库存
FBK04A05L1ZB 数据手册
FBA09A (92 X 25.5L) EMINEBEA.COM Allowable Ambient Temperature Range: -10°C ~ +70°C (65%RH) (Operating) -40°C ~ +75°C (65%RH) (Storage) (non-condensing environment) Failure Rate: 10% 50,000 Hours (40°C, 65%RH) inch Units: (mm) (Pa) (min - 1 ) .177 8 – (f4.5) ROTATION 1.00 .157 (25.5) .157 (4) (4) 60 12V(24V)-H 12V(24V)-M 3000 Static Pressure 3.25 (82.5) 3.62 (92) inlet outlet LR99935 NAME PLATE 40 12V(24V)-L 2000 Ps 3.25 (82.5) 3.62 (92) FLOW - Pin + Pin 20 1000 (m3/min) 0 1 2 3 Housing with solid corner type are available. Air Flow .185 4 – (f4.7) .185 4 – (f4.7) Bearing: Hydro Wave Bearing 3.54 (90) 3.25 (82.5) 3 (f1 .94 00 ) 3.54 (90) 3.25 (82.5) 3.25 (82.5) 3.54 (90) INLET SIDE OUTLET SIDE Rated Operating Voltage 4 (f1 .09 04 ) 3.25 (82.5) 3.54 (90) Current Input Power MODEL Voltage Rated Speed (min-1)*1 2200 2450 2950 2200 2450 2900 Max. Air Flow Max. Static Pressure Noise Normal Speed N Mass (V) FBA09A 12L FBA09A 12M FBA09A 12H FBA09A 24L FBA09A 24M FBA09A 24H Rotation: Clockwise (V) 7.0 ~ 13.8 7.0 ~ 13.8 7.0 ~ 13.8 14.0 ~ 27.6 14.0 ~ 27.6 14.0 ~ 27.6 (A)*1 110 150 255 80 110 140 (W)*1 1.32 1.80 2.70 1.92 2.64 3.36 CFM*1 (m3/min)*1 in H2O 42.7 48.0 56.8 42.7 48.0 56.8 1.21 1.36 1.61 1.21 1.36 1.61 .10 .11 .16 .10 .11 .16 (Pa)*1 25.5 29.4 42.1 25.5 29.4 42.1 (dB)*1 27.0 30.0 35.0 27.0 30.0 35.0 (g) 110 110 110 110 110 110 12 12 12 24 24 24 Airflow Outlet: Air Out Over Struts *1: Average Values in Free Air FEATURES Specifications of Various Sensors In Panaflo FBA series models, LOCKED ROTOR ALARM SIGNAL a locked rotor alarm sensor is Signal given when fan is running VH VL Signal given when fan is locked up VH VL V goes VL to VH Available Models Axial models FBK04F FAL Part Number Suffix 1BS S S S available in all models. For Blowers and Crossflo fans, a locked sensor can be provided as an option. A pulse sensor that transmits Panasonic FCB 2 PULSE PER REVOLUTION SIGNAL Signal given when fan is running VH VL Lock Signal given when fan is locked up A B Available Models Axial models except: FBK04F FBA06T FBA08T FCB FAL Part Number Suffix 1BX signals when the motor rotates is also available as an option. The 2 pulse per revolution sensor output is available in all FBA Series models except the 15 mm “T” versions. VL 1 Revolution 2PPR If fan locks on VH, signal stays locked. If fan locks on VL, signal stays at VL for a few hundred MS, then moves to VH. (A:B ˜1:5; A ≥ 100MS) Panaflo Built-in Connector System Lead Wire Connectors: Style: MASS TERMINATION (standard) AMP P/N 173977-3 CRIMP TYPE (this style is a 2 piece assembly) AMP P/N 175778-3 (housing) AMP P/N 175102-1 (terminal) Notes: •Connector style effects lead wire guage. Please refer to fan specs for further details. • All axial fans except the FBA06T, FBA08T and FBKO4F versions come standard with the mass termination connector. The FBA06T, FBA08T and FBKO4F fan leads are connected directly to the PC board in the fan assembly. • All FCB Crossflo models and FAL Blower fan leads are soldered directly to the PC board in the fan assembly. 2 High Reliability with HWB (Hydro Wave Bearing) Radial Direction Axial Direction shaft thrust plate bearing (b) HWB Figure 1: Pressure distribution in each load direction. washer HWB thrust plate stop ring shaft Figure 1: Construction of HWB Panaflo’s unique hydrowave bearing (HWB) addresses the traditional weakness of sleeve bearings…axial friction. By utilizing our unique HWB system, the thrust plate “floats” on a circulating film of oil, which greatly reduces the axial friction and the bearing’s deterioration. The HWB pattern on the bearing virtually eliminates thrust plate contact which is depicted above. As the shaft rotates it acts as a pump constantly circulating the oil in the radial, as well as the axial direction. The sealed system and reservoirs of oil maintain the proper lubrication to minimize mechanical contact and prolong the fan’s life expectancy. The radial direction analysis shown above is essentially the same as a traditional sleeve bearing. Panasonic’s unique HWB reduces the axial contact. 3 COMMON SPECIFICATIONS Protection • Locked rotor protection circuits • Automatically restarts in a few seconds • Reverse voltage protection Insulation Resistance • 10M Ω minimum at 500v DC (frame to leads) Panasonic Dielectric Strength • 500v AC (50/60Hz) for 1 minute (frame to leads) Plastic Rating • All Panaflo fans are manufactured with a UL94V-0 plastic (flammability) Noise Data Insulation Class • JIS Class E (120° C) • VDE Class E (90° C) • UL Class A (105° C) Microphone • CSA Class A (105° C) Noise Data The noise data is measured at 1 meter from the air intake side of the fan Microphone suspended in a semi-anechoic chamber (background noise 13dB-A max.). Construction with and without Solid Corner Housing Microphone Panaflo fans are available in two different versions for mounting: with solid corner housing and without. Specific mounting methods and applications require the use of solid corners. Select the appropriate housing for your application. Some models may be available only with solid corner housing. For details, please refer to the corresponding page for each model. * Distance 1m. With Solid Corner Without Solid Corner 4 PANAFLO FAN PRODUCT DESIGNATION CODE Panaflo Fan FBAO8A12H1AS Housing Size 04: 40 x 40mm 06: 60 x 60mm 08: 80 x 80mm 09: 92 x 92mm 12: 120 x 120mm Rated Voltage 12: 12 VDC 24: 24 VDC 05: 5 VDC Terminal (FBA Only) 1: With leads : No leads Option S: Locked rotor alarm sensor Z: Solid corner housing X: 2 PPR speed sensor (TAC Output) O: S + Z 1: Hub mounted thermal sensor (variable) Speed L: Low M: Middle H: High U: Ultra High V: Variable (Option) Bearing Type A: HWB (Hydro Wave) K: Ball Bearing (40mm Only) Housing Thickness A: 25.5mm T: 15mm (Thin) G: 38mm F: 20mm Motor Type FB: Panaflo (DC Axial-flow fan) Lead Wire (FBA Only) A: Standard 2 leads (GND, PWR) B: Standard 3 leads (GND, PWR, Signal) C: 3rd lead thermal sensor (variable) Crossflo Fan FCB34AD24S Fan Outside Diameter 34: Ø34 mm Rated Voltage Fan Motor Length Motor Type FCB: Brushless Crossflo Fan AA: 134.50mm AB: 173.50mm AC: 212.50mm AD: 251.50mm AE: 290.50mm AF: 329.50mm 12: 12 VDC 24: 24 VDC Option S: Locked rotor alarm sensor Blowers FAL6F12LHS Model Change Blower Size 3—50 x 50mm (Ball Bearing) 5—76 x 76mm (Hydro Wave) 6—109 x 114mm (Hydro Wave) Rated Voltage 05: 5 VDC 12: 12 VDC 24: 24 VDC Option S: Locked rotor alarm sensor Motor Type FAL: Brushless Fan Speed LL: Low Speed LH: High Speed 5 Type and Size Model Rated Voltage (V) 5 5 12 12 12 24 24 12 12 12 12 24 24 24 12 12 24 24 12 12 12 12 24 24 24 12 12 24 24 12 12 12 12 24 24 24 12 12 12 12 24 24 24 Operating Voltage (V) 4.5—6.0 4.5—6.0 7.0—13.8 7.0—13.8 7.0—13.8 14.0—27.6 14.0—27.6 7.0—13.8 7.0—13.8 7.0—13.8 7.0—13.8 14.0—27.6 14.0—27.6 14.0—27.6 7.0—13.8 7.0—13.8 14—27.6 14—27.6 7.0—13.8 7.0—13.8 7.0—13.8 7.0—13.8 14—27.6 14—27.6 14—27.6 7.0—13.8 7.0—13.8 14—27.6 14—27.6 7.0—13.8 7.0—13.8 7.0—13.8 7.0—13.8 14—27.6 14—27.6 14—27.6 7.0—13.8 7.0—13.8 7.0—13.8 7.0—13.8 14—27.6 14—27.6 14—27.6 Rated Current (mA) 120 280 75 150 170 92 100 110 130 170 210 70 90 105 88 145 56 83 68 124 173 270 54 71 105 79 200 47 110 110 150 225 430 80 110 140 180 340 460 510 110 160 230 Rated Input (W) 0.60 1.40 0.90 1.80 2.04 2.21 2.40 1.32 1.56 2.04 2.52 1.68 2.16 2.52 1.06 1.74 1.34 1.99 0.82 1.49 2.08 3.24 1.30 1.70 2.52 0.95 2.40 1.13 2.64 1.32 1.80 2.70 5.16 1.92 2.64 3.36 2.16 4.08 5.52 6.12 2.64 3.84 5.52 Nominal Speed (r/min) 4700 7500 4700 7500 9500 7500 9500 3200 3700 4200 4550 3200 3700 4200 3200 4200 3200 4200 1900 2450 2950 3450 1900 2450 2950 2000 3100 2000 3100 2100 2450 2850 3450 2100 2450 2850 1700 2100 2500 2750 1700 2100 2500 Maximum Air Flow (m3/min) (CFM) 0.11 0.19 0.11 0.19 0.26 0.19 0.26 0.40 0.47 0.54 0.58 0.40 0.47 0.54 0.34 0.47 0.34 0.47 0.68 0.91 1.12 1.33 0.68 0.91 1.12 0.62 0.95 0.62 0.95 1.21 1.36 1.61 1.95 1.21 1.36 1.61 1.95 2.45 2.94 3.25 1.95 2.45 2.94 3.9 6.7 3.9 6.7 9.2 6.7 9.2 14.1 16.6 19.1 20.5 14.1 16.6 19.1 12.0 16.6 12.0 16.6 24.0 32.1 39.6 46.9 24.0 32.1 39.6 21.9 33.5 21.9 33.5 42.7 48.0 56.8 68.8 42.7 48.0 56.8 68.9 86.5 103.8 114.7 68.9 86.5 103.8 Maximum Air Pressure (mmh20) (Pa) 2.50 6.60 2.50 6.60 24.5 64.7 24.5 64.7 Noise (dB-A) Safety Standard UL CSA Locked Rotor Alarm Sensor • • • • • • • FBK04F 40mm FBK04F05L FBK04F05H 24.0 33.0 23.0 32.0 42.0 33.0 42.0 24.0 28.0 32.0 37.0 24.0 28.0 32.0 24.0 32.0 24.0 32.0 21.0 28.0 32.0 38.2 21.0 28.0 32.0 23.0 34.0 23.0 34.0 27.0 30.0 35.0 43.0 27.0 30.0 35.0 30.0 35.5 41.5 45.5 30.0 35.5 41.5 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • DC axial fans FBK04F12L FBK04F12H FBK04F12U FBK04F24H FBK04F24U 12.00 117.7 6.60 64.7 12.00 117.7 3.10 3.95 5.20 6.0 3.10 3.95 5.20 2.80 4.75 2.80 4.75 1.57 2.51 3.78 4.80 1.57 2.51 3.78 1.55 3.20 1.55 3.20 2.30 3.00 3.98 5.0 2.30 3.00 3.98 3.30 4.80 6.80 8.0 3.30 4.80 6.80 30.4 38.7 51.0 58.0 30.4 38.7 51.0 27.5 46.6 27.5 46.6 15.4 24.6 37.1 47.0 15.4 24.6 37.1 15.2 31.4 15.2 31.4 22.6 29.4 39.0 49.0 22.6 29.4 39.0 32.4 47.1 66.7 38.0 32.4 47.1 66.7 Panasonic FBA06A 60mm FBA06A12L1A FBA06A12M1A • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • DC axial fans FBA06A12H1A FBA06A12U1A FBA06A24L1A FBA06A24M1A FBA06A24H1A FBA06T12L FBA06T12H FBA06T24L FBA06T24H FBA08A12L1A FBA08A12M1A FBA06T 60mm Thin FBA08A 80mm DC AXIAL FANS 28 DC axial fans FBA08A12H1A FBA08A12U1A FBA08A24L1A FBA08A24M1A FBA08A24H1A FBA08T 80mm Thin FBA08T12L FBA08T12H FBA08T24L FBA08T24H FBA09A 90mm FBA09A12L1A FBA09A12M1A DC axial fans FBA09A12H1A FBA09A12U1A FBA09A24L1A FBA09A24M1A FBA09A24H1A FBA12G 120mm FBA12G12L1A FBA12G12M1A DC axial fans FBA12G12H1A FBA12G12U1A FBA12G24L1A FBA12G24M1A FBA12G24H1A Type and Size Model Rated Voltage (V) 12 12 12 12 12 12 24 24 24 24 24 24 5 5 24 12 24 12 24 12 24 12 12 24 24 Operating Voltage (V) 10.2—13.8 10.2—13.8 10.2—13.8 10.2—13.8 10.2—13.8 10.2—13.8 20.4—27.6 20.4—27.6 20.4—27.6 20.4—27.6 20.4—27.6 20.4—27.6 4.5—6.0 4.5—6.0 7.0—13.8 7.0—13.8 14.0—27.6 7.0—13.8 14—27.6 7.0—13.8 14—27.6 7.0—13.8 7.0—13.8 14—27.0 14—27.0 Rated Current (mA) 165 340 375 415 430 440 110 165 200 210 230 250 205 380 111 185 105 200 100 140 70 280 500 155 295 Rated Input (W) 1.98 4.08 4.50 4.98 5.16 5.28 2.64 3.96 4.80 5.04 5.52 6.00 1.64 1.90 1.33 2.22 2.52 2.40 2.40 1.68 1.68 3.36 6.00 3.72 7.08 Nominal Speed (r/min) 2800 3300 3100 3000 2900 2800 2800 3300 3100 3000 2900 2800 4400 5400 4400 5200 5200 2900 2900 2400 2400 2100 2550 2100 2550 Maximum Air Flow (m3/min) (CFM) 0.32 0.61 0.80 0.96 1.14 1.22 0.33 0.64 0.80 0.95 1.10 1.15 0.112 0.140 0.112 0.138 0.138 0.30 0.30 0.25 0.25 0.53 0.65 0.53 0.67 11.3 21.5 28.2 33.9 40.3 43.1 11.7 22.6 28.2 33.5 38.8 40.6 3.95 4.94 3.95 4.87 4.87 10.6 10.6 8.83 8.83 18.7 23.0 18.7 23.7 Maximum Air Pressure (mmh20) (Pa) 1.30 3.00 2.00 1.90 1.90 1.85 1.50 2.40 2.00 2.00 2.10 2.20 8.1 15.4 8.4 15.0 15.0 12.7 29.4 19.6 18.6 18.6 18.1 14.7 23.5 19.6 19.6 20.6 21.6 79.4 151 79.4 151 151 Noise (dB-A) Safety Standard UL CSA Locked Rotor Alarm Sensor • • • • • • • • • • • FCB34 FCB34AA12 38.0 42.0 42.0 42.0 42.0 42.0 39.0 42.0 42.0 42.0 42.0 42.0 28.5 36.0 28.5 35.0 35.0 36.0 36.0 30.0 30.0 40.0 45.0 40.0 45.0 • • • • • • • • • • • • • • • • • • • • • • • • • • • • Crossflo Fans FCB34AB12 FCB34AC12 FCB34AD12 FCB34AE12 FCB34AF12 FCB34AA24 FCB34AB24 FCB34AC24 FCB34AD24 FCB34AE24 FCB34AF24 FAL3F Blowers FAL3F05LH FAL3F05LL FAL3F12LL FAL3F12LH FAL3F24LH CROSSFLO BLOWERS FAL5F FAL6F • • • • • • • • • • • • • • FAL5F12LH FAL5F24LH FAL5F12LL FAL5F24LL FAL6F12LL FAL6F12LH FAL6F24LL FAL6F24LH 10.00 98.07 9.70 6.20 6.30 95.12 60.8 61.8 11.25 110.3 18.00 176.5 11.50 112.8 19.70 193.2 29
FBK04A05L1ZB 价格&库存

很抱歉,暂时无法提供与“FBK04A05L1ZB”相匹配的价格&库存,您可以联系我们找货

免费人工找货