0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CJR5E88TGWH

CJR5E88TGWH

  • 厂商:

    PANDUIT

  • 封装:

    Module

  • 描述:

    插件 转

  • 数据手册
  • 价格&库存
CJR5E88TGWH 数据手册
Mini-Com® TX6™ PLUS UTP Jack Modules S P E C I F I CAT I O N S H E E T specifications Category 6/Class E, 8-position, UTP jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm unshielded twisted pair cable and shall not require use of a punchdown tool. UTP jack modules shall use a forward motion termination method to optimize performance by maintaining cable pair geometry while eliminating conductor untwist. The termination cap shall be color-coded white to designate Category 6 performance and shall include a universal label coded for T568A and T568B wiring schemes. technical information Category 6/Class E channel and component performance: Exceeds channel requirements of ANSI/TIA-568.2-D Category 6 and ISO 11801 Class E standards at swept frequencies 1 to 250 MHz Exceeds component requirements of ANSI/TIA-568.2-D Category 6 and ISO 11801 Class E standards at swept frequencies 1 to 250 MHz FCC and ANSI compliance: Meets ANSI/TIA-1096-A contacts plated with 50 microinches of gold for superior performance IEC compliance: Meets IEC 60603-7 and IEC 60512-99-001 RoHS compliance: Compliant PoE & PoH compliance: Rated for 2500 cycles with IEEE 802.3af / 802.3at and 802.3bt type 3 and type 4. Supports Power over HDBaseT up to 100 watts UL rated: UL 1863 (Use as communications circuit accessory) UL 2043 (Suitable for use in air-handling spaces) Operating Temperature: -10°C to 65°C (14°F to 149°F) Conductor termination range: Wire cap compatible with 22 – 26 AWG solid or stranded cable with conductor insulation diameters of 0.060 in. max. and overall cable O.D. 0.200 in. to 0.330 in. key features and benefits 100% performance tested Confidence that each jack module will deliver the critical electrical performance requirements Utilizes enhanced Giga-TX ™ Technology Optimizes performance by eliminating conductor untwist and reduces installation time and expense Modular UTP jack modules snap in and out of all Mini-Com ® Faceplates, Modular Patch Panels and Surface Mount Boxes for easy moves, adds, and changes Individually serialized Marked with quality control number for future traceability RJ45 interface Industry standard interface provides a quick and easy plug and play connection to RJ45 patch cords; backwards compatible Identification Can be clearly identified with optional labels and icons for port identification Angle termination version available Side opening allows cable to be terminated to the right or left side of the jack module; ideal for installations that have minimal depth that may not allow standard bend radius practices to be accommodated Termination tools (optional) EGJT-1 termination tool ensures conductors are fully terminated by utilizing a smooth forward motion without impact on critical internal components for maximum reliability; TGJT termination tool ideal for high volume installations Block out device (optional) Provides a simple and secure method to control access to data ports while not in use Shuttered version (optional) Integrated spring shuttered door keeps out dust and debris of unmated RJ45 jack modules automatically applications Mini-Com ® TX6™ PLUS UTP Jack Modules are a component of the TX6™ PLUS UTP Copper Cabling System. This end-to-end system is interoperable and backwards compatible, providing design flexibility to protect network investments well into the future. With certified performance to the ANSI/TIA-568.2-D Category 6 and ISO 11801 Class E standards, this system is ideal for today's high performance workstation applications. With certified performance to the ANSI/TIA-568.2-D Category 6 and ISO 11801 Class E standards, these systems will support the following applications: • Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet) • 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM • Token Ring 4/16 • Digital video and broadband/baseband analog video • Voice over Internet Protocol (VoIP) w w w . pa n d u it.c o m TX6 ™ PLUS UTP Copper Cabling Systems Mini-Com ® TX6 ™ PLUS UTP Jack Modules Jack module: CJ688TG* Shuttered jack module: CJH688TG* Up/Down 45° angle jack module: CJUD688TG* Left/Right 45° angle jack module: CJLR688TG* Tools and Accessories Jack module termination tool: EGJT-1 or TGJT Wire snipping tool: CWST Wire stripping tool: CJAST Clear dust cap: MDC-C Block out device: PSL-DCJB-^^^ Phone icons: CIPIW-C+ Data icons: CIDIW-C+ *To designate color, add suffix: IW (Off White), replace IW suffix with WH (White), EI (Electric Ivory), WH (White), IG (International Gray), AW (Arctic White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange), VL (Violet), BR (Brown), GD (Gold), LB (Light Blue), or PK (Pink). ^^^To designate color other than Red, add suffix Black (BL), Blue (BU), Yellow (YL), Green (GR), Orange (OR), Off White (IW) or International Gray (IG) at the end of the part number. 10/package. + To designate color other than IW (Off White), replace IW with EI (Electric Ivory), IG (International Gray), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange), or VL (Violet) in the part number. 100/package. Contact customer service for bulk packaged and/ or keyed jack modules and patch cords. Mini-Com® TX6™ PLUS UTP Jack Modules test results Mechanical Test Normal Force Test Method Measurement Typical Test Results — Load (grams) > 100 Vibration IEC 512-6d Circuit Resistance (mOhms) < 40 Shock IEC 512-6c Contact Disturbance (microseconds) 20 IEC 60603-7 Number of plug insertions > 2500 Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Test Method Measurement Typical Test Results IEC 512-9b Circuit Resistance (mOhms) < 40 Termination Cycles Mating Cylces Electrical Test Environmental Test Temperature Life Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 0.71 (18.06) 0.62 (15.87) Jack Module and Standard Wire Cap 1.50 (38.15) Jack Module Shuttered Jack Module Dimensions are in inches (Dimensions in parenthesis are metric) WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK cs-emea@panduit.com Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300 ©2019 Panduit Corp. ALL RIGHTS RESERVED. COSP317--WW-ENG Replaces WW-COSP48 4/2019
CJR5E88TGWH 价格&库存

很抱歉,暂时无法提供与“CJR5E88TGWH”相匹配的价格&库存,您可以联系我们找货

免费人工找货