Technical Data Sheet
High Tack Thermal Transfer Printable Polyester Film
This specification is intended to outline the physical and chemical properties of PANDUIT’s pressure sensitive high tack thermal
transfer printable polyester material and include the following printable material identifiers:
YPT
YPT-P
Y0T
Y0T-P
YPC
Printable Material Suffixes
YQT-P
YUT-P
YRT-P
YVT-P
YST-P
YWT-P
YTT-P
Y8T-P
A*1
Y9T-P
Y*1
AJC (Flag Label)
AJT (Flag Label)
PRODUCT SPECIFICATIONS:
Description:
Material is RoHS compliant (European Union directive
2002/95/EC). Material is a top coated polyester film with a
pressure sensitive adhesive.
Print Methods:
This material is recommended for thermal transfer printing.
Adhesive:
Rubber based, pressure sensitive high tack permanent adhesive
Standard Colors:
Various colors
Thickness:
3.9 +/- 0.3 mils (substrate and adhesive)
Service Temperature Range:
-40°F to 302°F (-40°C to 150°C)
Minimum Application Temperature:
50°F (10°C)
Storage Conditions:
Store at 70°F (21°C) and 50% Relative Humidity.
PROPERTIES:
PERFORMANCE:
Peel Adhesion to Stainless Steel:
Shear Adhesion:
100 oz/in width minimum (PSTC-101, 15 min. dwell)
24 hours minimum (PSTC-107, modified Procedure A)
Tensile Strength:
MD 36 +/- 3.6 lbs./inch width (PSTC-131)
TD 41 +/- 4.1 lbs./inch width (PSTC-131)
MD 80% +/- 15% (PSTC-131)
TD 75% +/- 15% (PSTC-131)
Elongation:
UV Resistance:
*3000 hours no visual change observed for both white and colored labels
(ASTM G154).
5000 hours no visual change observed for white but significant fade
observed for colored labels but print still legible (ASTM G154).
10,000 hours slight yellowing observed for white, complete fade for
colored labels but print still legible (ASTM G154)
Elevated Temperature Exposure:
After 8 hours at 150°F (65.5°C) there was no deterioration of the substrate
*3000 hours equates to 5 years of assimilated outdoor UV exposure.
Page 1 of 4
2020PANDUIT Corp
TDS: GMY4-HT
18900 Panduit Drive
Tinley Park, IL 60487
Customer Service: 800-777-3300
TDS:
Effective Date:
Revision:
GMY4-HT
31AUG20
11
Technical Data Sheet
PROPERTIES FOR SOLAR
PERFORMANCE:
APPLICATION:________________________________________________________________________________
Short term low temperature exposure:
30 days at -51C, no visible change observed
Short term high temperature exposure:
30 days at 93C, no visible change observed
Relative Lightfastness and weatherability:
1000 hours, no change observed (ASTM D3424, Method 4)
Tensile Strength:
MD: 10114 PSI (ASTM D3759)
Elongation:
MD: 90% (ASTM D3759)
Tack:
12.6 N (ASTM D2979)
Flammability:
16 seconds (ASTM D1000)
Adhesion:
154.0 oz/in (ASTM D3330)
CHEMICAL/SOLVENT RESISTANCE:
The testing was conducted at room temperature. Samples were orange/red (flexo) preprinted and thermal transfer printed
with Panduit RMR*BL/RMER*BL ribbon on the Panduit TDP43MY/TDP43ME printer. Separate sets were conditioned
for 24 hours before being immersed in the following solvents for a period of 1 hour and 24 hours. After the samples were
removed from the immersed solvents, they were rubbed 10 times with a lint free gauze. Visual observations were noted for
any smear or loss of legibility.
1 Hour Immersion
Chemical/Solvent
Ribbon only
Visual Observation
Colored Flexo Ink
Jet Fuel
Gasoline
Methyl Ethyl
Ketone
1:1:1 TCE
Trichloroethylene
No change
Loss in print density
Loss in print density
No change
No change
Orange/red ink removed
Loss in print density
Loss in print legibility
Orange ink removed
Orange/red ink removed
409 Cleaner
Alpha Flux 200L
No change
No change
No change
No change
Page 2 of 4
2020PANDUIT Corp
TDS: GMY4-HT
TDS:
Effective Date:
Revision:
18900 Panduit Drive
Tinley Park, IL 60487
Customer Service: 800-777-3300
GMY4-HT
31AUG20
11
Technical Data Sheet
24 Hours Immersion
Chemical/Solvent
Visual Observation
Ribbon only
Colored Flexo Ink
Isopropyl Alcohol
No change
No change
Orange ink removed
No change
No change
No change
No change
Loss in print legibility
No change
No change
No change
No change
No change
No change
Orange ink removed
No change
No change
No change
Water 150°F
Salt Water
SAE 30 Motor Oil
Hydraulic Fluid
Skydrol
Methanol/Water
Ethylene Glycol
ASTM #3 Oil
Reference
ASTM: American Society for Testing and Materials (U.S.A.)
PSTC:
Pressure Sensitive Tape Council
APPROVALS
UL Recognized: UL969
CUL Recognized: C22.2 No 0.15-01
Page 3 of 4
File number:
File number:
MH 14979
MH 14979
2020PANDUIT Corp
TDS: GMY4-HT
TDS:
Effective Date:
Revision:
18900 Panduit Drive
Tinley Park, IL 60487
Customer Service: 800-777-3300
GMY4-HT
31AUG20
11
Technical Data Sheet
PROPERTIES FOR HARSH WASHDOWN ENVIRONMENT (with overlaminate film)
Meets the requirements of Ingress protection rating standard DIN 40050-9, IP69K for labels used in harsh wash-down and high
pressure spray applications, common to the food and beverage industries.
CHEMICAL RESISTANCE TEST:
Samples were printed with RMER4BL ribbon on Panduit TDP43ME printer and overlaminated with a clear film
(T225X000YK1 or T425X000YK1). These samples were adhered to stainless steel panels and immersed in the following
solvents. Testing consisted of 10 cycles of 10 minutes immersion followed by a 20 minute recovery period. After final
immersion, visual observations were noted for any smear or loss of legibility.
CHEMICAL/SOLVENT
Enforce LP
TEMPERATURE
500C
Print
No change
Adhesive
No change
HD PL-10 Plus
RT
No change
No change
Heavy Duty Acid LC-30
No change
No change
No change
No change
No change
No change
Vortexx
700C
500C
RT
500C
No change
No change
XY-12
RT
No change
No change
Soil Off II
Madisan 75
LIMITED WARRANTY
All PANDUIT Identification Solution Products (except for Software programs) are warranted to be free from defects in material and workmanship at the
time of sale but our obligation under this warranty is limited to replacement of the product proved to be defective within 6 months from the date of
sale, or in the case of printers, within 90 days from the date of sale. This warranty is void if the products or printers are modified, altered or misused
in any way. Use of PANDUIT printers with any product other than the specified PANDUIT products for which the printer was designed constitutes
misuse. Before using, the user shall determine the suitability of the product for its intended use and user assumes all risk and liability whatsoever in
connection therewith. The foregoing may not be altered except by an agreement signed by officers or seller and manufacturer.
NEITHER PANDUIT OR SELLER SHALL BE LIABLE FOR ANY OTHER INJURY, LOSS OR DAMAGE, WHETHER DIRECT OR CONSEQUENTIAL,
ARISING OUT OF THE USE OF, OR THE INABILITY TO USE THE PRODUCT OR THE PRINTER.
THIS WARRANTY IS MADE IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS OF PARTICULAR USE ARE SPECIFICALLY EXCLUDED.
The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a guide or use by
persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with
its use. Dimensions contained herein are for reference purposes only. This publication is not to be taken as a license to operate under, or a
recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc.
Page 4 of 4
2020PANDUIT Corp
TDS: GMY4-HT
很抱歉,暂时无法提供与“F100X300AJT”相匹配的价格&库存,您可以联系我们找货
免费人工找货