Wiring Duct Control Panel
Overview
PANDUCT ® Type H — Hinged Cover Wiring Duct
•
•
•
•
Made of rigid PVC
UL Recognized continuous use temperature: 50°C (122°F)
UL94 Flammability Rating of V-0
Provided with mounting holes
Control
Panel
Special
Environment
Voice &
Data
Part Number
H1.5X2LG6
H1.5X3LG6
H2X2LG6
H2X3LG6
H2X4LG6
H3X3LG6
H3X4LG6
H4X4LG6
H
Duct Size WxH
In.
mm
1.75 x 1.98
1.75 x 3.06
2.17 x 1.98
2.17 x 3.06
2.17 X 4.10
3.25 x 3.06
3.25 x 4.10
4.25 x 4.10
44.5 x 50.3
44.5 x 77.7
55.1 x 50.3
55.1 x 77.7
55.1 X 104.1
82.6 x 77.7
82.6 x 104.1
108.0 x 104.1
Cover
Part
Number
HC1.5LG6
HC1.5LG6
HC2LG6
HC2LG6
HC2LG6
HC3LG6
HC3LG6
HC4LG6
Available in BL (Black), LG (Light Gray) and WH (White).
W
Tools &
Accessories
Reference
Page(s)
Color Availability
F14
Adhesive Tape
E12
Dimensions
F7
Wirefill Guide
F9
Material
Specifications
F13
Tools & Accessories D11, D12,
Section E
Installation Tips
F15
Technical
Info
Index
B12
Order number of feet required, in multiples of 6' or Standard Carton Quantity. Base and cover sold separately.
Duct
Cover
Std. Ctn. Std. Ctn.
Qty.
Qty.
120
120
120
60
60
60
60
60
120
120
120
120
120
120
120
60
Length
(ft)
6
6
6
6
6
6
6
6
Wiring Duct for Special Environments
Overview
PANDUIT ® offers a selection of special materials in PANDUCT ® Wiring Duct for
routing and concealing wiring in special use environments. Special use environments
include applications such as transportation, oil and gas platforms, nuclear power plants
Control
Panel
Environment/Material Specifications
and semiconductor and electronics manufacturing.
Some of the features and benefits found in PANDUCT ®
Wiring Duct types for special environments include:
Special
Environment
Specialty materials will not release toxic or
corrosive gases that could endanger public safety or
damage sensitive electronics, and exhibits excellent
flame retardance
Flush cover design to maximize capacity over the
channel footprint and provide a neater appearance
Voice &
Data
Integrated non-skid liner insures the duct cover will
not slide once installed or during vibration
Smooth corners and edges will not abrade cabling or
irritate hands
UL Recognized as meeting the requirements of
UL Standard 1565 for Positioning Devices
Tools &
Accessories
CE compliant for panels that are to be exported
to Europe
Technical
Info
Index
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
C1
Wiring Duct for Special Environments
Overview
Control
Panel
Type NNC Halogen Free Metric Wiring Duct
Halogen free material is nontoxic, lead-free,
environmentally safe and will not release toxic
or corrosive gases that could endanger public
safety or damage sensitive electronic equipment
Special
Environment
UL94V-0
Data &
Voice
Type NE NORYL* Halogen Free Wiring Duct
Halogen free material is nontoxic, lead-free,
environmentally safe and will not release toxic
or corrosive gases that could endanger public
safety or damage sensitive electronic equipment
UL94V-1
Tools &
Accessories
Type TMC Low Smoke/Low Toxicity Wiring Duct
Low smoke/Low toxicity material emits a low
level of toxic fumes and low smoke emissions
when burned
Technical
Info
Meets Federal Rail Administration Guidelines and
NFPA 130 requirements for all transit vehicles
UL94V-0
Index
The material is
self-extinguishing and
has excellent flame
retardancy UL94V-0.
*NORYL is a registered trademark of General Electric Company.
C2
The material does
not release dense
smoke when burned
per ASTM E662 test
method.
The material does
not emit a high
volume of toxic gases
when burned per
Boeing and Airbus
test methods.
Overview
Control
Panel
Environment/Material Specifications
Typical Applications
PAGES
C4/C5
Semiconductor Manufacturing
Ship Building
Nuclear Power Plants
Oil Platforms
Environment/Material Specifications
Typical Applications
Special
Environment
PAGES
C6/C7
Data &
Voice
Semiconductor Manufacturing
Ship Building
Nuclear Power Plants
Oil Platforms
Tools &
Accessories
Environment/Material Specifications
Typical Applications
PAGES
C8/C9
Passenger Rail Cars
Other Transportation Vehicles
Technical
Info
The material contains
no fluorine, bromide
or chlorine and will not
emit any corrosive or
toxic gases when
burned per IEC 60754-2
test method.
Material is rated
for a continuous use
temperature above
75˚ C (167˚ F).
Index
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
C3
Wiring Duct Special Environments
Overview
PANDUCT ® Type NNC — Halogen Free Metric Wiring Duct
• Made of halogen free material and verified with IEC 60754-2
test method (test on gases evolved during combustion of
electric cables)
• UL Recognized continuous use temperature: 95°C (203°F)
• UL94 Flammability Rating of V-0
• Conforms with NFPA 79-2002 section 14.3.1 requirement for
flame retardant material
• Provided with DIN 43 659 mounting holes
• Metric sizing and finger progression
• Duct and cover packaged together in 2 meter lengths
Control
Panel
Special
Environment
Duct Size WxH
mm
In.
Part Number
• nonmetallic, non-flame
propagating CDS
• medium impact resistance
• 211 temperature classification
• cover removal without tools
Data &
Voice
W
H
NNC25X25LG2
NNC25X37LG2
NNC25X50LG2
NNC25X75LG2
NNC37X37LG2
NNC37X50LG2
NNC37X75LG2
NNC50X50LG2
NNC50X75LG2
NNC50X100LG2
NNC75X75LG2
NNC100X50LG2
NNC100X75LG2
NNC100X100LG2
24.6
24.6
24.6
24.6
37.1
37.1
37.1
49.5
49.5
49.5
74.7
99.6
99.6
99.6
Technical
Info
Reference
Page(s)
Color Availability
F14
Adhesive Tape
E12
Dimensions
F5
Wirefill Guide
F9
Material
Specifications
F13
Tools and
Accessories
Installation Tips
C4
23.6
35.8
47.8
72.4
35.8
47.8
72.4
47.8
72.4
97.8
72.4
47.8
72.4
97.8
.97 x .93
.97 x 1.41
.97 x 1.88
.97 x 2.85
1.46 x 1.41
1.46 x 1.88
1.46 x 2.85
1.95 x 1.88
1.95 x 2.85
1.95 x 3.85
2.94 x 2.85
3.92 x 1.88
3.92 x 2.85
3.92 x 3.85
Duct
Cover
Std. Ctn. Std. Ctn.
Qty.
Qty.
Length
(M)
20
20
20
20
20
20
20
20
20
20
NC37LG2
20
20
20
20
20
20
2
NC50LG2
10
10
10
10
20
20
20
20
2
10
10
20
20
2
NC25LG2
NC75LG2
NC100LG2
2
2
Available in LG (Light Gray) and WH (White).
Do not allow cutting, tapping or cleaning fluids that contain hydrocarbons to come in contact with Type NNC
Wiring Duct as it will cause stress cracking. See page F15 for a list of chemicals to avoid.
Tools &
Accessories
Index
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Replacement
Cover Part
Number
E9, E10,
E13, E14
F15
Order number of meters required, in multiples of Standard Carton Quantity.
®
PANDUCT ® Wiring Duct
Overview
Rounded Edges
V-Shaped Slot Lead-In
Halogen Free
Non-Slip
Cover Liner
Restricted Slots
Control
Panel
Specially Formulated
Halogen Free
Material
Metric Finger
Width and
Progression
Special
Environment
Upper Scoreline
Features
Lower Scoreline
Advantages
Benefits
Material is nontoxic, lead-free, environmentally
safe and will not release toxic or corrosive
gases that could endanger public safety or
damage sensitive electronics
Ideal for application where public safety during a
fire is a concern
Greater resistance to heat than PVC
Suitable for panel applications where high
temperatures exist
UL94V-0 material flame rating
The V-0 flammability rating exceeds the rating
of most other halogen free duct materials
Material is self-extinguishing and exhibits the
highest flame retardance meeting more electrical
panel applications
Halogen free non-slip cover liner
Cover will not slide easily when installed on
duct base
Cover stays in place during shipment,
vibration and when in a vertical orientation,
eliminating rework
Co-extruded liner made from halogen
free material
Liner will not emit corrosive or toxic gases
DIN 43 659 mounting hole pattern
Provides the required mounting hole pattern
for use in cabinets which are designed to
these standards
Meets European standards for use in
cabinet applications
Smooth rounded edges
Exclusive PANDUIT ® process rounds the
edges in duct slots and at top of duct fingers
Protects hands and wiring/cabling from abrasion
Double scoreline
Upper scoreline at base of finger allows fingers Allows quick modification for larger cabling
to be broken out without tools
bundles saving installation time leading to a lower
installed cost
Halogen free modified
PPO material
Material is recyclable and suitable for applications
requiring eco-friendly materials
Lower scoreline at base of duct allows sidewall
sections to be removed
Easier to create tee and corner junctions with full
wire carrying capacity
V-shaped slot lead-in
V-shape funnels wires into slot for
easier insertion
Speeds wire installation
Double restricted slot design
Once inserted wires are retained in the slot
with or without the cover being installed
Eliminates hassle and saves time during
installation and maintenance
Second restriction retains cabling within top
or bottom portion of slot in larger wiring
duct sizes
Provides a neat and finished appearance
Duct and cover packaged together
Fewer part numbers to stock and manage
Reduced inventory cost
Metric size and finger progression
Slot width and pitch may match more closely to Provides a metric sized wiring duct solution for
components with metric dimensions
applications that specify metric dimensioning,
such as when exporting equipment to
European countries
For service and technical support, call 800-777-3300 (outside the U.S. and Canada, see back cover).
Voice &
Data
Tools &
Accessories
Technical
Info
Index
C5
很抱歉,暂时无法提供与“H2X4LG6”相匹配的价格&库存,您可以联系我们找货
免费人工找货