0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
IAPHF2MWH-X

IAPHF2MWH-X

  • 厂商:

    PANDUIT

  • 封装:

  • 描述:

    INDUSTRIAL MINI-COM 2-POSITION 1

  • 数据手册
  • 价格&库存
IAPHF2MWH-X 数据手册
IndustrialNet ™ Data Access Port S p e c i f i c a t i o n S H EET specifications IndustrialNet ™ Data Access Port The industrial data access port shall provide end users a safe and secure means to maintain and monitor performance of PLCs, VFD, and industrial networks. Integrated security features shall prevent the intentional disruption of service by unauthorized personnel. Non-arc flash certified personnel shall access the panel reducing cost, increasing efficiencies, and promoting overall safety. Aluminum casted base with clear plastic impact resistant cover and modular faceplate mount shall protect all connections. GFCI data access port with TX5e™ Coupler and blank: IAPNG5EWH GFCI data access port: IAPNGWH Empty data access port: IAPNWH European data access port (empty): IAPEWH Mini-Com ® Modules+ technical information NEMA/UL Type 4X and Type 12, IP65 rating: Compression latch and integrated gasket design protect against dust and moisture UL recognized component: UL recognized component per standards ANSI/UL 943, “Ground-Fault Circuit-Interrupters” and CSA-C22.2 No. 144.1-06, “Ground-Fault Circuit-Interrupters” key features and benefits Modular Accepts select Mini-Com® modules including copper, fiber, USB ports, serial ports, and HMI memory components to provide design flexibility Integrated GFCI receptacle outlet Provides power to external monitoring devices preventing downtime associated with overloading critical system components Locking hasp Accepts Panduit lockout/tagout products or padlock to prevent unauthorized access for improved security Removable mounting plate Accepts a variety of power supplies providing flexibility to meet regional electrical requirements Identification Meets TIA/EIA-606-A labeling standards allowing identification of data and power, reducing downtime during maintenance and trouble shooting Covered screw holes Prevents unintentional disruption of service by unauthorized personnel and protection against arc flash improving security, safety, and network uptime Pre-configured mounting template Quickly and easily identifies mounting hole locations and cutouts TX6A™ 10Gig ™ UTP Jack Module: TX6 ™ PLUS UTP Jack Module: TX5e ™ UTP Jack Module: TX6 ™ 10Gig ™ Shielded Jack Module: TX6 ™ PLUS Shielded Jack Module: TX5e ™ Shielded Jack Module: Category 5e coupler module: Category 6 coupler module: USB coupler module: CJ6X88TGIW* CJ688TGIW* CJ5E88TGIW* CJS6X88TGY CJS688TGY CJS5E88TGY CC5E88BL CC688BL IAPCMUSBAAWH Patch Cords Please visit www.panduit.com for the complete list of patch cord offerings. 1/3 Size Inserts and Blanks Flat, 2-port: Flat: 9-pin female/female coupler: 15-pin high-density female/female coupler: 15-pin high-density D-sub: Blank module: IAPHF2MWH-X IAPHB2MWH-X IAPHD9CWH IAPHD15HDCWH IAPHD15HDSCWH IAPCMBWH-X *For standard colors other than Off White, replace suffix IW (Off White) with EI (Electric Ivory), WH (White), IG (International Gray), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green), YL (Yellow), or VL (Violet). +For additional Mini-Com™ Modules please visit www.panduit.com applications The IndustrialNet™ Data Access Port provides data port and electrical outlet access to control panels without the safety hazards of opening the panel. The access port provides availability to log in to the network at the work site and can be used for reprogramming internal controllers and setting up a print terminal. The modular design allows for RJ45 jacks, USB, and other modular connectors which can be interchanged to customize for maximum design w w w . pa n d u it.c o m Note: Custom mounting plates available upon request. flexibility. Snap on mounting plate covers mounting screws and prevents tampering or unauthorized removal of access port from the control panel. Access port can also be locked with a padlock to secure the outlet. Versions IAPNG5EWH, IAPNGWH are configured with GFCI power receptacle for the United States. IAPEWH is configured to accept standard 45mm European outlets. Note: Versions IAPNG5EWH and IAPNGWH are configured with GFCI power receptacle for the United States; IAPEWH is configured with a 45mm opening to accept standard European outlets. IndustrialNet ™ Data Access Port 7.00 [177.8] 7.00 [177.8] IndustrialNet™ Data Access Port Faceplate IndustrialNet™ Data Access Port Faceplate Panduit 1/3 Flat Two-Position Insert 7.28 [185.0] 7.28 [185.0] Panduit ® Mini-Com® Blank Module Panduit 1/3 Flat Blank Insert Panduit Category 5e RJ45 to RJ45 Coupler Module 15 Amp GFCI Duplex Outlet 15 Amp GFCI Duplex Outlet IAPNG5EWH IAPNGWH 7.00 [177.8] 7.00 7.00 7.00 [177.8] [177.8] [177.8] IndustrialNet™ Data Access Port Faceplate Data IndustrialNet IndustrialNet™™™Data Data IndustrialNet Access Port Faceplate AccessPort PortFaceplate Faceplate Access 7.28 7.28 7.28 [185.0] [185.0] [185.0] 7.28 [185.0] IAPEWH IAPNWH Dimensions are in inches. [Dimensions in brackets are metric]. PANDUIT CANADA Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK cs-emea@panduit.com Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300 ©2014 Panduit Corp. All rights reserved. COSP263--WW-ENG Replaces WW-COSP169 6/2014
IAPHF2MWH-X 价格&库存

很抱歉,暂时无法提供与“IAPHF2MWH-X”相匹配的价格&库存,您可以联系我们找货

免费人工找货