ELECTRICAL SOLUTIONS
A.
System
Overview
Flex Conductor, One-Hole, Standard Barrel with Window, Flared NEBS Lug,
90° Angle
B1.
Cable Ties
For Use with Flexible and Extra-Flexible Copper Conductors
Type LCAF-F
• Can be used with flex conductor class: K, M, and Diesel Locomotive
• Flared entry prevents bent back strands when inserting fine strand
conductor into barrel
• Color-coded barrels marked with Panduit die index numbers for
proper crimp die selection
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit crimping tools and dies
• Tested by Telcordia – meets NEBS Level 3
• American Bureau of Shipping Approved
C2.
Surface
Raceway
T
90˚
C3.
Abrasion
Protection
B
FLARED
ENTRY
L
Part Number
LCAF8-10F-L
C4.
Cable
Management
Figure Dimensions
(In.)
Flex Conductor Size
Class K and M
Diesel
Locomotive
—
#8 AWG
LCAF8-14F-L
Stud Hole
Size (In.)
#10
W
0.41
B
0.76
T
0.08
L
0.93
Panduit
Color
Code
Red
Panduit
Die Index
No.‡
P21
Std.
Wire Strip Pkg.
Length (In.) Qty.
13/16
50
1/4
0.48
0.76
0.07
1.02
Red
P21
13/16
50
5/16
0.56
0.76
0.05
1.14
Red
P21
13/16
50
LCAF8-38F-L
3/8
0.60
0.76
0.05
1.24
Red
P21
13/16
50
LCAF6-10F-L
#10
0.45
0.81
0.09
1.52
Blue
P24
7/8
50
LCAF8-56F-L
LCAF6-14F-L
1/4
0.48
0.81
0.08
1.06
Blue
P24
7/8
50
5/16
0.56
0.81
0.07
1.18
Blue
P24
7/8
50
LCAF6-38F-L
3/8
0.62
0.81
0.06
1.28
Blue
P24
7/8
50
LCAF4-10F-L
#10
0.55
0.81
0.09
1.07
Gray
P29
7/8
50
LCAF4-14F-L
1/4
0.55
0.81
0.09
1.16
Gray
P29
7/8
50
5/16
0.55
0.81
0.09
1.28
Gray
P29
7/8
50
3/8
0.62
0.81
0.07
1.38
Gray
P29
7/8
50
LCAF6-56F-L
LCAF4-56F-L
#6 AWG
#4 AWG
#6 AWG
#4 AWG
LCAF4-38F-L
LCAF2-14F-E
1/4
0.70
0.88
0.11
1.35
Brown
P33
15/16
20
LCAF2-56F-E
5/16
0.70
0.88
0.11
1.48
Brown
P33
15/16
20
3/8
0.70
0.88
0.11
1.55
Brown
P33
15/16
20
1/2
0.79
0.88
0.09
1.79
Brown
P33
15/16
20
LCAF2-38F-E
#2 AWG
#2 AWG
LCAF2-12F-E
LCAF1-14F-X
1/4
0.76
0.94
0.12
1.49
Pink
P42
1
10
LCAF1-56F-X
5/16
0.76
0.94
0.12
1.54
Pink
P42
1
10
3/8
0.76
0.94
0.12
1.62
Pink
P42
1
10
LCAF1-12F-X
1/2
0.80
0.94
0.12
1.85
Pink
P42
1
10
LCAF1/0-14F-X
1/4
0.85
1.35
0.13
1.64
Black
P45
1 7/16
10
LCAF1/0-56F-X
5/16
0.85
1.35
0.13
1.70
Black
P45
1 7/16
10
3/8
0.85
1.35
0.13
1.70
Black
P45
1 7/16
10
1/2
0.85
1.35
0.13
1.95
Black
P45
1 7/16
10
LCAF1-38F-X
LCAF1/0-38F-X
LCAF1/0-12F-X
#1 AWG
1/0 AWG
#1 AWG
1/0 AWG
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
INSPECTION
WINDOW
W
B2.
Cable
Accessories
‡See pages D3.74, D3.75 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
Table continues on page D2.78
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
F.
Index
ELECTRICAL SOLUTIONS
A.
System
Overview
Flex Conductor, One-Hole, Standard Barrel with Window, Flared NEBS Lug,
90° Angle (continued)
B1.
Cable Ties
Figure Dimensions
(In.)
Flex Conductor Size
B2.
Cable
Accessories
L
1.71
Panduit
Color
Code
Orange
Panduit
Die Index
No.‡
P50
0.13
1.71
Orange
P50
1 7/16
10
0.13
1.77
Orange
P50
1 7/16
10
1.35
0.13
2.02
Orange
P50
1 7/16
10
1.06
1.35
0.14
1.81
Purple
P54
1 7/16
10
5/16
1.06
1.35
0.14
1.82
Purple
P54
1 7/16
10
3/8
1.06
1.35
0.14
1.89
Purple
P54
1 7/16
10
LCAF3/0-12F-X
1/2
1.06
1.35
0.14
2.12
Purple
P54
1 7/16
10
LCAF4/0-14F-X
1/4
1.17
1.35
0.14
1.88
Yellow
P62
1 7/16
10
5/16
1.17
1.35
0.14
1.90
Yellow
P62
1 7/16
10
3/8
1.17
1.35
0.14
1.97
Yellow
P62
1 7/16
10
LCAF4/0-12F-X
1/2
1.17
1.35
0.14
2.20
Yellow
P62
1 7/16
10
LCAF250-38F-X
3/8
1.28
1.65
0.17
2.21
White
P66
1 3/4
10
1/2
1.28
1.65
0.17
2.32
White
P66
1 3/4
10
5/8
1.28
1.65
0.17
2.53
White
P66
1 3/4
10
LCAF250-78F-X
7/8
1.28
1.65
0.17
2.97
White
P66
1 3/4
10
LCAF300-38F-6
3/8
1.39
1.65
0.18
2.44
Red
P71
1 3/4
6
LCAF300-12F-6
1/2
1.39
1.65
0.18
2.44
Red
P71
1 3/4
6
Stud Hole
Size (In.)
1/4
W
0.96
B
1.35
T
0.13
5/16
0.96
1.35
3/8
0.96
1.35
LCAF2/0-12F-X
1/2
0.96
LCAF3/0-14F-X
1/4
Part Number
LCAF2/0-14F-X
Class K and M
Diesel
Locomotive
2/0 AWG
2/0 AWG
LCAF2/0-56F-X
LCAF2/0-38F-X
B3.
Stainless
Steel Ties
LCAF3/0-56F-X
C1.
Wiring
Duct
LCAF3/0-38F-X
3/0 AWG
3/0 AWG
LCAF4/0-56F-X
C2.
Surface
Raceway
LCAF4/0-38F-X
4/0 AWG
4/0 AWG
LCAF250-12F-X
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
LCAF250-58F-X
LCAF300-58F-6
300 kcmil
262.6 kcmil
313.1 kcmil
5/8
1.39
1.65
0.18
2.65
Red
P71
1 3/4
6
LCAF300-78F-6
7/8
1.39
1.65
0.18
3.04
Red
P71
1 3/4
6
LCAF350-38F-6
3/8
1.54
1.85
0.22
2.40
Blue
P76
1 15/16
6
LCAF350-12F-6
1/2
1.54
1.85
0.22
2.40
Blue
P76
1 15/16
6
5/8
1.54
1.85
0.22
2.77
Blue
P76
1 15/16
6
3/4
1.54
1.85
0.22
2.91
Blue
P76
1 15/16
6
LCAF350-78F-6
7/8
1.54
1.85
0.22
3.16
Blue
P76
1 15/16
6
LCAF350-1F-6
1
1.54
1.85
0.22
3.28
Blue
P76
1 15/16
6
LCAF400-12F-6
1/2
1.70
2.20
0.26
3.28
Brown
P87
2 1/4
6
5/8
1.70
2.20
0.26
3.28
Brown
P87
2 1/4
6
7/8
1.70
2.20
0.26
3.28
Brown
P87
2 1/4
6
LCAF350-58F-6
LCAF350-34F-6
LCAF400-58F-6
LCAF400-78F-6
D3.
Grounding
Connectors
250 kcmil
Std.
Wire Strip Pkg.
Length (In.) Qty.
1 7/16
10
350 kcmil
400 kcmil
373.7 kcmil
444.4 kcmil
‡See pages D3.74, D3.75 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.