0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PFBC36EI18

PFBC36EI18

  • 厂商:

    PANDUIT

  • 封装:

    -

  • 描述:

    RACEWAY PD3/PD6 FLEX TO CONDUIT

  • 数据手册
  • 价格&库存
PFBC36EI18 数据手册
RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Table of Contents Introduction Page Page Raceway Solutions for Total Flexibility .......................................................... ii-v 1 2 3 4 Faceplate Options ............................................................... vi Manufacturers’ Module Frame Cross Reference............................................ vii PAN-POLE ™ Power & Communication Pole ................................................ viii FIBER-DUCT ™ Routing System.................................................................. viii Tips for Selecting a Surface Raceway .............................................................ix Fiber Optic Specification Compliant Features...............................................x-xi The Preferred Options .................................................................................... xii PAN-WAY Type PD Surface Raceway Base & Cover ..................................D7 PAN-WAY Type PD Raceway F ittings ..........................................................D8 Fill Capacities for Electrical, UTP and STP Cables .......................................D9 Fill Capacities for Coax and Fiber Optic Cables ..........................................D10 PAN-WAY ™ Faceplates and Electr ical Outlets PAN-WAY Snap-On Electrical/Communication Faceplates.......................... A3 PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates. A3 PAN-WAY Stainless Steel U.S. Standard Screw -On Electrical/Communication Faceplates .......................................................A4 PAN-WAY U.S. Standard Electrical Outlets.................................................. A4 PAN-WAY 20A Low Profile Surface Mount Outlet Box with 20A Electrical Outlet ..........................................................................A4 PAN-WAY Brazilian Standard Electrical Faceplates .................................... A5 PAN-WAY French Standard 45X45mm Snap-On Faceplate ........................A5 PAN-WAY German Schuko and French/Belgium Electrical Outlets and Faceplates............................................................................... A6 PAN-WAY DIN Standard Two-Piece Surface Mount Outlet Box................... A6 PAN-WAY Faceplates and Brackets for Italian Type Electrical Outlets ....... A6 PAN-WAY Australian Type Screw-On Electrical Outlet ................................ A7 PAN-WAY UK Style Electrical Modules and Faceplates .............................. A7 PAN-WAY Type T-70 & Twin-70 Non-Metallic Surface Raceways PAN-WAY T-70 & Twin-70 Non-Metallic Raceways—Roadmaps................. B3 PAN-WAY Type T-70 Surface Raceway Configurations ..........................B4-B5 PAN-WAY Type T-70 Surface Raceway System Features ........................... B6 PAN-WAY Type T-70 Surface Raceway Base & Cover ................................ B7 PAN-WAY Type T-70 Fittings...................................................................B7-B8 PAN-WAY WORKSTAT ION OUTLET CENTER ™ Offset Box.................................................................................................. B8 PAN-WAY Type T-70 Fill Capacities for Electrical, UT P and STP Cables....................................................................................... B10 PAN-WAY Type T-70 Fill Capacities for Coax and F iber Optic Cables.................................................................................. B11 PAN-WAY Type Twin-70 Surface Raceway Configurations.................B12-B13 PAN-WAY Type Twin-70 Surface Raceway System Features .................... B14 PAN-WAY Type Twin-70 Surface Raceway Base & Cover......................... B15 PAN-WAY Type Twin-70 F ittings ................................................................ B16 PAN-WAY Type Twin-70 F ill Capacities for Electrical, UTP and STP Cables....................................................................................... B18 PAN-WAY Type Twin-70 F ill Capacities for Coax and F iber Optic Cables.................................................................................. B19 PAN-WAY Type T-70 & Twin-70 Raceway Accessories............................. B20 T-70 Snap-On F iber Spool Bracket ............................................................. B20 PAN-WAY FAST-SNAP™ Surface Mount Outlet Boxes............................. E3 PAN-WAY Low Voltage Surface Mount Outlet Boxes ..................................E3 PAN-WAY Power Rated Surface Mount Outlet Boxes .................................E4 PAN-WAY Divided Surface Mount Outlet Boxes.......................................... E5 Raceway Adapters......................................................................................... E5 Selection Chart for using PAN-WAY Plastic Surface Raceways with PAN-WAY Surface Mount Outlet Boxes...................................................E6 PAN-WAY Type TE-70 Non-Metallic Surface Raceway PAN-WAY Type TE-70 Non-Metallic Raceway—Roadmap.......................... F3 PAN-WAY Type TE-70 Raceway Configurations....................................F 4-F5 PAN-WAY Type TE-70 Surface Raceway Base & Cover.............................. F6 PAN-WAY Type TE-70 Fittings .....................................................................F6 PAN-WAY Type TE-70 Accessories ............................................................. F7 Fill Capacities for Electrical, U TP and STP Cables ....................................... F9 Fill Capacities for Coax and Fiber Optic Cables .......................................... F10 PAN-WAY Type T Sur face Raceway System PAN-WAY Type T Raceway—Roadmap ......................................................G3 PAN-WAY Type T Raceway C onfigurations ...........................................G4-G7 PAN-WAY Type T Surface Raceway Applications ........................................G8 PAN-WAY Type T Surface Raceway and Accessories .................................G9 PAN-WAY Type T Raceway F ittings...........................................................G10 PAN-WAY Type T Box & Pre-Cut Cover (for NEMA Faceplates)................G10 PAN-WAY Type T Snap-On Faceplate Pre-Cut C overs for MINI-COM ® Snap-On Modular Furniture Faceplates)......................G11 PAN-WAY Type T130 Hanging Device Bracket & Molded Covers .....G11-G12 Fill Capacities for Electrical, UT P and STP C ables .....................................G15 Fill Capacities for Coax and Fiber Optic Cables ..........................................G16 PAN-WAY Sur face Raceway System Accessor ies PAN-WAY Surface Raceway Cutting Tool....................................................H1 Floor Guard and Magnet Strip .......................................................................H1 Open Office Products PAN-POLE™ Outlet Pole Components PAN-POLE Aluminum Outlet Pole—Roadmap ............................................. I3 PAN-POLE Aluminum Outlet Pole Configurations .................................... I4-I5 PAN-POLE Aluminum Outlet Pole Components ........................................... I6 PAN-POLE Accessories............................................................................... I7 Standard Included Mounting Hardware .......................................................... I7 Installation Instructions ................................................................................... I8 Fill Capacities for Electrical, UT P and STP Cables ...................................... I10 Fill Capacities for Coax and Fiber Optic Cables ........................................... I11 PAN-WAY LD Profile Surface Raceway Systems PAN-WAY LD Profile Non-Metallic Raceways Data On ly —Roadmaps...... C3 PAN-WAY LD Profile Non-Metallic Raceways Power Only—Roadmaps ... C4 PAN-WAY LD Profile Non-Metallic Raceways Multichan nel Data & Power—Roadmap................................................. C5 PAN-WAY LD Profile Raceway Configurations ......................................C6-C7 PAN-WAY LD Profile Raceways—System Features..............................C8-C9 PAN-WAY Type LDP Surface Raceway..................................................... C10 PAN-WAY Type LDS Surface Raceway..................................................... C11 PAN-WAY Type LD Surface Raceway ....................................................... C12 PAN-WAY Type CD Surface Raceway ...................................................... C13 Standard Fittings for Low Voltage Applications ........................................... C14 1" Bend R adius Fittings for T IA/EIA Compliance ........................................ C14 Power Rated Fittings for Power to 600V...................................................... C15 PAN-WAY Type LD2P Multi-Channel Surface Raceway ........................... C16 Multi-Channel Fittings for Multi-Channel Power & Low Voltage Applications ............................................................................................. C16 Fill Capacities for LD Profile Raceways ...............................................C17-C18 PAN-WAY Type PD Surface Raceway System PAN-WAY Type PD Raceways—Roadmaps................................................ D3 PAN-WAY Type PD Profile Raceway Configurations............................. D4-D5 PAN-WAY Type PD Profile Raceways—System F eatures ........................... D6 Telecommunication Equipment Room Products FIBER-DUCT™ Routing System PANDUCT® Solid and Slotted Wall Wiring Duct........................................... J3 FIBER-DUCT System Fittings ................................................................ J3-J4 Transition Fittings, Mounting Brackets and Accessories ........................... J4-J5 Fiber Optic Adhesive Markers........................................................................ J5 Fill Capacities for PANDUCT Type E or Type S ........................................... J6 PAN-WAY Technical Information NEW TIA/EIA 569-A Requirements for Surface Raceway........................ xiv-xv NEW UL-5A Standard Explanation................................................................ xvi CSA 22.2 Standard Explanation ...................................................................xvii NEC Article 352B Standard Explanation ...................................................... xvii Mounting Guidelines & Flammability ........................................................... xviii Material Physical Properties .......................................................................... xix Raceway Typical Specifications ............................................................... xx-xxii Alphabetical Part Number Index ...........................................................xxiii-xxvi Refer to back cover for information regarding Panduit’s complete line of structured cabling products. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) i TABLE OF CONTENTS Surface Raceway Products PAN-WAY Surface Mount Outlet Boxes RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY The PAN-WAY ™ Line The universal non-metallic surface raceway and surface mount outlet box line that accommodates communication outlets made by most manufacturers and that also accommodates all standard U.S. Electrical outlets and a number of international electrical outlets. The method of choice for Data-Com installations! Non-metallic surface raceway has become the method of choice for Data-Com installations because of its many advantages: • • • • • • Low installed cost High density of outlets Accessibility Ease of modifications and additions Bend radius control Good appearance Applications Include (but not limited to): • schools and universities • office environments • laboratories • training centers • libraries • customer service areas • manufacturing facilities For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) ii RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Solutions for “total flexibility” Other raceway systems use non-standard faceplates or frames designed to tie in a specific proprietary connectivity solution, limiting your connectivity choice. Panduit Raceway Systems are designed around NEMA (70mm) Standard Faceplates, the same faceplates used for in-wall applications. This provides you “total flexibility” when making your connectivity choice. NEMA Standard Solutions 83.5mm (NEMA Std.) 70mm (Common) Standard solutions use electrical and communication outlets and faceplates that meet the required NEMA (70mm) standard. They are universal because every U.S. Manufacturer must meet this standard to provide in-wall outlets and faceplates. U.S. Electrical faceplates have been made to NEMA (70mm) specifications for years. Data-Com faceplates for the U.S. typically match the U.S. Electrical faceplates in size and appearance. In addition, most Data-Com manufacturers provide module frames which adapt standard NEMA (70mm) electrical faceplates to mount their communications modules. STANDARD COMMUNICATIONS MODULE FRAME STANDARD ELECTRICAL OUTLET STANDARD FACEPLATE Global Electrical Outlet Solutions Data-Com is common worldwide, however, electrical outlets and faceplates are not (i.e. standards vary). This problem has been solved by the PAN-WAY ™ line which provides international electrical outlets in faceplates that match the U.S. Electrical and Data-Com faceplates in size and appearance. The result is that the PAN-WAY line is universal in the U.S. and internationally. (Note: A WORKSTATION OUTLET CENTER ™ offset box is required for German outlets). It can also be used for the installation of Data-Com modules from virtually any source. U.S. Style International Style (UK shown) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) iii RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Faceplates Various PAN-WAY ™ surface raceways and surface mount outlet boxes and PAN-POLE ™ Outlet Poles accommodate the following faceplates: 1. PAN-WAY Snap-On Electrical/Communication Faceplates These match standard NEMA (70mm) faceplates, however, they snap-on instead of screw-on. The electrical faceplates accommodate standard NEMA (70mm) 106 and rectangular duplex electrical outlets. These same faceplates accommodate communication outlets made by most manufacturers when used in conjunction with module frames which they provide to adapt their communication outlets to standard faceplates. The module frame is screw mounted to the box or raceway mounting frame and this faceplate is snapped over it. PAN-WAY Snap-On Faceplates PAN-WAY Electrical Outlets Communication Module Frames See page A3 See page A4 See page vii for list of compatible frames 2. PAN-WAY Snap-On Communication Faceplates with Screw Holes to Mount a Module Frame These are identical to PAN-WAY Snap-On Electrical/Communication faceplates, however, they have screw holes to mount any manufacturers’ module frames to these faceplates which eliminates the need for mounting frames for certain raceway applications such as T-70 and Twin-70. PAN-WAY Snap-On Faceplates Communication Module Frames with Screw Holes See page vii for list of compatible fr ames See page A3 3. U.S. Standard Screw-On Electrical/Communication Faceplates Standard electrical/communication faceplates match standard NEMA (70mm) faceplates. These accommodate all the same electrical and/or communication outlets and module frames as PAN-WAY Snap-On Faceplates. Some PAN-WAY surface mount outlet boxes accommodate only screw-on faceplates. PAN-WAY screw-on electrical/communication faceplates match PAN-WAY Snap-On electrical/communication faceplates in appearance and are recommended for such applications. Most Data-Com manufacturers supply NEMA (70mm) standard screw-on faceplates and they can be used anywhere PAN-WAY snap-on or screw-on electrical/communication faceplates are used. PAN-WAY Screw-On Faceplates PAN-WAY Electrical Outlets Communication Module Frames See page A3 See page A4 See page vii for list of compatible fram es For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) iv RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY 4. U.S. Standard Screw-On Communication Faceplates Standard communication faceplates that match standard NEMA (70mm) faceplates are supplied by any manufacturer for their communication modules. These include PAN-NET ™ and PAN-WAY ™ Communication Products Screw-On communication faceplates made by Panduit. PAN-WAY Screw-On Communication Faceplates for Panduit PAN-NET Modules Other styles available 5. Panduit ® Snap-On Communication Faceplates PAN-NET style snap-on faceplates accommodate communication modules made by Panduit without the need for module frames. PAN-WAY Communication Products style snap-on faceplates accommodate communication modules made by Panduit without the need for module frames. Snap-On Communications Faceplates for Panduit PAN-NET and PAN-WAY Communication Modules NOTE: R efer to PAN-NET Communication Catalog (SA101N152E-OP) for information on our complete line of PAN-NET Faceplates and Modules. PAN-WAY General Purpose Standard “Keystone” Communication Modules and Faceplates (SA101N435-OP—Available 4th Quarter 1999). 6. International Faceplates In addition to the above, Panduit provides: Electrical faceplates and international electrical outlets that match the NEMA (70mm) faceplates in size and appearance and mount on various PAN-WAY surface raceways and surface mount outlet boxes. PAN-WAY International Faceplates Brazil France Italy UK Australia Germany See page A5 thru A7 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) v RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Faceplates PAN-WAY ™ PLASTIC SURFACE RACEWAY Various PAN-WAY ™ surface raceways, surface mount outlet boxes and PAN-POLE™ Outlet Poles accommodate the following faceplates: Faceplate Description Works With PAN-WAY Snap-On Electrical/Communication Faceplates • Accommodate electrical/communication outlets • Snap over outlet or module frame when mounted to a raceway channel or a FAST-SNAP ™ Surface Mount Outlet Box 1 Mo st Mfg. Standard Electrical Outlets Mo st Mfg. Co mmun ication Mo dule F rames See Column A or B next page PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) • Accommodate communication outlets • Outlet attaches directly to faceplate which snaps on a raceway channel or on a FAST-SNAP Surface Mount Outlet Box 2 Most Manufacturers’ Co mmun ication Modu le Fram es See Column A or B next page PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates • Accommodate electrical/communication outlets • Screw mount over outlet or module frame when mounted to a surface mount outlet box or raceway mounting bracket or box 3 Mo st Mfg. Standard Electrical Ou tlets Most Mfg . Comm unication Modu le Frames See Column A or B next page U.S. Standard Screw-On Communication Faceplates • Standard communication faceplates that match standard NEMA (70mm) Faceplates supplied by any manufacturer for their communication modules • These include PAN-NET and PAN-WAY ™ Screw-On Communication Faceplates made by Panduit 4 Standard Manufacturers’ Faceplate & Modules PAN-WAY International Electrical Faceplates • Electrical faceplates and international electrical outlets that match the NEMA (70mm) Faceplates in size and appearance and mount on various PAN-WAY Surface Raceways and Surface Mount Outlet Boxes See page A5 thru A7 NOTE: See the “configuration pages” in each section of this catalog for detailed information on how to complete a termination using the solutions shown above. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) vi RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Communication Module Frames Compatible with PAN-WAY ™ Electrical/Communication Faceplates for PAN-WAY Surface Raceway and PAN-POLE ™ Outlet Poles Panduit ® and Other Manufacturers’ Module Frame Part Numbers B Module Frames for use with MANUFACTURER Module Frames for use with 106 Style Rectangular Electrical/Communication Faceplates Electrical/Communication Faceplates Panduit PAN-NET CF1064** CFG1**, CFG2**, CFG4** Lucent Technologies M106FR2, M106FR4 M108FR3 Amp 558302-* 558321-* Hubbell 106 DUPLEX SERIES: BR106*, BR106*** STYLINE SERIES: FSL244*, FSL244** , FSL344*, FSL344** Krone 6644 1 106-** 6644 1 107-** N/A Leviton 41070-*** , 41071-***, 41072-***, 41087-*** 40850**, 41642-*, 41666-*, 41688-* , 41658-*, 41668-* Mod-Tap 11.B008, 11.B029 11.B034, 11.B030 Nordx/CDT MDVO 106 Adapters: NXMAA2-0* (AX10030*) NXMAA4-0* (AX10031*) MDVO Deco Adapter: QNE4AG(10*)(A040965*) Ortronics OR-62850001-**, OR-62850002-**, up to OR-62850024-** OR-63650001-**, OR-63650002-**, up to OR-63650024-** Siemon MX-E2A-**, MX-E2F-** , MX-E4A-* *, MX-E4F-** MX-D1-** , MX-D2-**, MX-D4-** Contact Panduit for other manufacturers not shown above. “ ” Designates a color option. * PAN-WAY Electrical/Communication Faceplates are compatible with the current design of all of the frames listed; however, it is the customer’s responsibility to confir m the current suitability of any par ticular faceplate/frame combination. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) vii PAN-WAY ™ PLASTIC SURFACE RACEWAY A RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY The PAN-POLE ™ Outlet Pole Line Accepts the same 70mm cover as surface raceway. Aluminum Outlet Poles for power and communications in an open office environment. These accommodate the same power and communication outlets and faceplates as the PAN-WAY ™ line, however, compliance with local specifications must be checked for international installations. The FIBER-DUCT ™ Routing System For routing cabling to and from racks and other cable managers within the closet, Panduit features the FIBER-DUCT Routing System. The system has two sizes, 2" x 2" and 4" x 4" with fittings that maintain a minimum 2" bend radius. The product is available in a number of colors to code the type of cable being routed. There is a full line of mounting brackets available. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) viii RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Tips for Selecting a Surface Raceway How to select a PAN-WAY ™ Surface Raceway: 1. Determine the cabling systems to be routed: Data Only, Power Only or Both Power & Data Low Voltage (Data) Raceway Systems LDP, LD2P, LDS, PD, Twin-70, T-70, T105,T130, T170, T3, TE70 Multichannel Raceway Systems (Route Power & Data) LD2P, Twin-70, T-70, T105,T130, T170, T3, TE70 2.Consider the special requirements of the cable type used: UTP Category 5 cabling: Per the TIA/EIA specification, UTP Category 5 cabling must maintain a cable bend radius of 1" (4 times the cable outside diameter.) Raceway Systems with 1" Bend Radius Fittings 1" Twin-70, T-70, any LD Profile raceway using 1" Bend Radius Fittings The symbol at left is used throughout this catalog to indicate a system fitting that maintains the minimum 1" bend radius for Categor y 5 and fiber optic cabling. Fiber Optic Cabling: For the special handling requirements of Fiber Optic Cabling see the explanation on the next page. The Panduit PAN-WAY Surface Raceway Systems listed are part of the FIBER-SPEC™ System optimized for routing fiber optic cabling: • Tw in-70 R aceway System • T-70 Racew ay System • LD P R aceway System • LD2P Racew ay System 3.Compare the cable diameter (s) and number of cables to be routed with the raceway fill capacity tables provided: Data Grade Cables These tables are located in the back of each raceway section in this catalog. SPEC: Use this number when specifying a new surface raceway system. MAX : The maximum number of cables that can be accommodated within the specified raceway channel. (T-70 Cat5 fills) 24 AWG UT P CM 25 pr Cat. 5 4 pr DIA.= 0.422 DIA.=0.217 F ILL FILL SPEC MAX SPEC MAX 15 22 56 84 4.Find a Termination Configuration to meet your requirements: CONFIGURATIONS 1 2 3 Each section contains a configuration section which calls out the components required to terminate each of the solutions shown in the chart on page vi . Look for the color coded numbers to quickly identify the solution. 4 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) ix SELECTING RACEWAY Any PAN-WAY Surface Raceway System can be used for routing low voltage cabling, however if some cables have bend radius limitations the proper raceway fittings must be used. Power Rated Raceway Systems RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Fiber Optic Cabling Panduit has identified the following criteria, based on the TIA/EIA standards and good cabling practices, which should be taken into consideration when selecting a raceway system to route fiber optic cabling: SELECTING RACEWAY • Must provide security and segregation • Must provide bend radius protection for the cabling • Must provide the installer with access to 1 meter of fiber optic cabling Must provide security and segregation • Installation of divider wall maintains separated security for fiber cables. Must provide bend radius protection for the cabling • Panduit FIBER-SPEC ™ Raceway Systems all maintain minimum 1" bend radius control throughout system. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) x RACEWAY SOLUTIONS FOR TOTAL FLEXIBILITY Must provide the installer with access to 1 meter of fiber optic cabling SELECTING RACEWAY 1 met er When cover is not installed, length of cable in raceway is removed to provide access. If additional length of cable is desired, bend radius controlled storage loop is installed on base of raceway (see page B20). Fiber jack to be reterminated Raceway cover and faceplate are snapped on providing security and segregation. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xi N E W THE PREFERRED OPTIONS Available Only From Panduit ® Integral Snap-On Faceplates SNAP-ON to PAN-WAY ™ Surface Raceway and FAST-SNAP ™ Surface Mount Outlet Boxes. Communication modules snap directly into faceplate. Available for Panduit PAN-NET ™ and PAN-WAY Communication Modules. THE ADVANTAGES Faceplate Snaps Directly on to Raceway Channel or FAST-SNAP Surface Mount Outlet Box INSERTS ARE NOT REQUIRED MODULE FRAMES ARE NOT REQUIRED* SCREWS ARE NOT REQUIRED Modules Snap Directly into Faceplate Sloped Housings Molded In VERSIONS TO ACCEPT PAN-NET OR NEW PAN-WAY COMMUNICATION MODULES Superior Appearance — No Screws Integral Screw-On Faceplates THE ADVANTAGES INSERTS ARE NOT REQUIRED MODULE FRAMES ARE NOT REQUIRED* NEMA STANDARD SCREW-ON to PAN-WAY Surface Raceway and FAST-SNAP Surface Mount Outlet Boxes. Communication modules snap directly into faceplate. Available for Panduit PAN-NET and PAN-WAY Communication Modules. U.S. Standard Screw-On Faceplate NEMA Standard Hole Spacing NEMA STANDARD HOLE SPACING AND 70m m WIDTH Sloped Housings Molded In VERSIONS TO ACCEPT PAN-NET OR NEW PAN-WAY COMMUNICATION MODULES Modules Snap Directly into Faceplate 70mm SEE CATALOG Panduit PAN-WAY General Purpose Standard “Keystone” Communication Modules and Faceplates (Available 4th quarter) Panduit PAN-NET Specification Grade Communication Modules and Faceplates SA101N435-OP SA101N152E-OP *NOTE: Module frames are available for Panduit PAN-NET communication modules, however, they are not recommended. Integral snap-on faceplates which are available for these communication modules are a superior solution because no module frame is required and all screws are eliminated. xii NOTES For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xiii A Surf ace R aceway P roduct s PAN-WAY ™ PLASTIC SURFACE RACEWAY B77 PAN-WAY ™ Faceplates and Electrical Outlets PAN-WAY Faceplates and Electrical Outlets are available to mount, conceal and terminate power and communications with PAN-WAY Plastic Surface Raceway and surface mount outlet boxes. All are available in colors to match and complement the raceway and surface mount outlet boxes. NEW! Faceplates Electrical Outlets • U.S. Standard Screw-On Electrical/Communication Faceplates • New PAN-WAY Snap-On Faceplates available for electrical/communication applications • All electrical/communication faceplates are UL 5A Listed to 600V and CSA Certified to 300V • Available in 4 standard colors • Select styles available in up to 7 colors • Standard electrical devices • Available styles: 20A 106 Duplex 20A Rectangular TVSS Rectangular GFCI Rectangular • New 20A Low Profile Surface Mount Outlet Boxes include box and 20A outlet • Available in 2 colors IN TERN ATI ONA L OU TLET SOLU TION S See page A5 thru A7 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A1 PAN-WAY ™ PLASTIC SURFACE RACEWAY Table of Contents Page PAN-WAY ™ Snap-On Faceplates Electrical/Communication Faceplates . . . . . . . . . . . . . A3 Electrical/Communication Faceplates (with screw holes for module frames) . . . . . . . . . . . . . A3 PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates PAN-WAY Duplex Screw-On Faceplates . . . . . . . . . . A3 PAN-WAY Rectangular Screw-On Faceplates . . . . . . A3 PAN-WAY Stainless Steel Faceplates . . . . . . . . . . . . A4 PAN-WAY Electrical Outlets & Low Profile Outlet Boxes 20A 106 Duplex and Rectangular Outlets. . . . . . . . . . A4 TVSS Surge Suppression Outlet. . . . . . . . . . . . . . . . . A4 GFCI Ground Fault Outlet . . . . . . . . . . . . . . . . . . . . . . A4 20A Low Profile, 106 Duplex and Rectangular . . . . . . A4 International Outlets . . . . . . . . . . . . . . . . . . . . . . . .A5-A7 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A2 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Snap-On Electrical/Communication Faceplates Part Number Description Color ◆ Std. Pkg. Qty. Std. Ctn. Qty. Single Gang 106 Duplex Electrical/Communication Snap-On Faceplate T70PIW T70P T70PG Snap-on faceplate covers one NEMA standard 106 duplex Off White electrical outlet. In communication applications covers one standard 106 communication module frame. No mounting screws required to install faceplate. 1 pc. 10 pcs. Single Gang Rectangular Electrical/Communication Snap-On Faceplate T70PGIW Snap-on faceplate covers one NEMA standard rectangular Off White electrical outlet. In communication applications covers one rectangular communication module frame. No mounting screws required to install faceplate. 1 pc. 10 pcs. Single Gang 106 Duplex Communication Snap-On Faceplate* (with scr ew holes to mount a m odule frame) T70PSIW Snap-on faceplate covers one NEMA standard 106 duplex Off White module frame. Module frame screw mounts directly to underside of snap-on faceplate. No device bracket needed. Supplied with one mounting screw. 1 pc. 10 pcs. Single Gang Rectangular Communication Snap-On Faceplate* T70PSIW T70PGSIW (with scr ew holes to mount a m odule frame) T70PGSIW Snap-on faceplate covers one NEMA standard rectangular Off White communication module frame. Module frame screw mounts directly to underside of snap-on faceplate. No device bracket needed. Supplied with two mounting screws. 1 pc. 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. *Not for use with electrical devices PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates NEW! Par t Number Description Std. Pkg. Qty. Std. Ctn. Qty. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Color◆ JSingle Gang 106 Duplex Screw-On Faceplate CP106IW CP106 CP106**-2G Covers one NEMA standard 106 duplex electrical outlet. In communication applications, covers one standard 106 communication module frame. Supplied with one mounting screw. JDouble Gang 106 Duplex Screw-On Faceplate CP106IW-2G Covers two NEMA standard 106 duplex electrical outlets. In communication applications, covers two standard 106 communication module frames. Supplied with two mounting screws. JSingle Gang Rectangular Screw-On Faceplate CPGIW CPG CPG* *-2G Covers one NEMA standard rectangular electrical outlet. In communication applications, covers one standard rectangular communication module frame. Supplied with two mounting screws. JDouble Gang Rectangular Screw-On Faceplate CPGIW-2G Covers two NEMA standard rectangular electrical outlets. In communication applications, covers two standard rectangular communication module frames. Supplied with four mounting screws. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), RD (Red), BR (Brown) and BL (Black). Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A3 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Stainless Steel U.S. Standard Screw-On Electrical/Communication Faceplates Part Number Description Color Std. Pkg Qty. Std. Ctn. Qty. Single Gang 106 Duplex Stainless Steel Faceplate J WPS-20 WPS-20 WPS-202 Covers one NEMA standard 106 duplex electrical outlet. In communication applications covers one standard 106 communication module frame. Supplied with one mounting screw. — 1 pc. 10 pcs. — 1 pc. 10 pcs. Description Color◆ Std. Pkg. Std. Ctn. Qty. Qty. 20A U.S. style 106 duplex outlet. Supplied with two mounting screws. Off White 10 pc. 100 pcs. Off White 10 pc. 100 pcs. Double Gang 106 Duplex Stainless Steel Faceplate J WPS-202 Covers two NEMA standard 106 duplex electrical outlets. In communications applications covers two standard 106 module frames. Supplied with two mounting screws. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. PAN-WAY U.S. Standard Electrical Outlets Compatible with all PAN-WAY Surface Raceway and Surface Mount Outlet Boxes Part Number 106 Duplex Electrical Outlet EDU20IW-X NEW! NEW! Rectangular Electrical Outlet ERU20IW-X 20A U.S. style rectangular outlet. Supplied with two mounting screws. Rectangular Transient Voltage S urge Suppression Electrical Outlet ETU20IW-X EDU20**-X NEW! ERU20**-X 20A TVSS rectangular outlet. Supplied with two mounting screws. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Rectangular Ground Fault Circuit Interrupt Electrical Outlet NEW! EGU20IW-X 20A GFCI rectangular outlet. Supplied with two mounting screws. 106 duplex and rectangular style outlets fit into surface mount outlet boxes, and are compatible with all PAN-WAY Surface Raceways. ETU20IW-X ◆ All parts listed in Off White color (IW). For Electrical Ivory substitute (EI). ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. EGU20IW-X PAN-WAY ™ Surface Mount Outlet Box with 20A Electrical Outlet NEW! Part Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Surface Mount Outlet Box with 20A Rectangular Electrical Outlet J JBP1MR20IW JBP1MR20 NEW! JSurface Mount Outlet Box with 20A 106 Duplex Electrical Outlet JBP1MD20IW JBP1MD20 Two-piece power rated Low Profile Surface Mount Outlet Box. Supplied with 20A U.S. style rectangular electrical outlet. Two-piece power rated Low Profile Surface Mount Outlet Box. Supplied with 20A U.S. style 106 duplex electrical outlet. ◆ All parts listed in Off White color (IW). For Electrical Ivory substitute (EI). OR DERING INFORMATION: Order number of pieces required, in multiples of Standard Package. NOTE: See Selection Chart on page E6 for detailed information on specific usage with raceways. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A4 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Brazilian Standard Electrical Faceplates NEW! Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Color◆ Single Gang Snap-On Electrical Faceplate T70PBIW Covers one Brazilian electrical outlet. No screws required to mount faceplate. Single Gang Screw-On Electrical Faceplate T70PB FP1B FP1BIW Covers one Brazilian electrical outlet. Supplied with two mounting screws. Double Gang Screw-On Electrical Faceplate FP2BBIW Covers two Brazilian electrical outlets. Supplied with two mounting screws. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and FP2BB WH (White). Contact factory for details. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. PAN-WAY French Standard 45X45 Snap-On Faceplate Par t Num ber Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. 45X45mm Snap-On Electrical/Communication Faceplate (accepts 45X45 modules) T70BL2IW T70BL2 Single gang snap-on electrical/communication faceplate accepts two (2) 45x45mm French power outlet modules or four (4) half size modules. Off White 1 pc. 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A5 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ German Schuko and French/Belgium Electrical Outlets and Faceplates Part Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. German Schuko Style Electrical Outlet EID16AW-X 16A Schuko style outlet. 55mm x 55mm. Arctic White 10 pcs. 100pcs. French/Belgium Style Electrical Outlet EID16 EIF16 ESD10 EIF16AW-X 16A French/Belgium style outlet. 55mm x 55mm. Arctic White 10 pcs. 100pcs. Double Pole Switch ESD10AW-X 10A double pole switch Arctic White 10 pcs. 100pcs. Single Gang Faceplate for German Schuko and French/Belgium Standard Electrical Outlets FCFP1PAW-X FCFP1P Single gang faceplate for 55mm x 55mm electrical outlet or switch. Arctic White 10 pcs. 100pcs. ◆ All parts listed in Arctic White (AW) color. To order other colors substitute IW (Off White) or IG (Light Gray). Contact factory for details. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. PAN-WAY DIN Standard Two-Piece Surface Mount Outlet Box Par t Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Two-Piece DIN Box DJBXAW DJBX Single gang DIN box — base and cover. Conduit breakouts: 25mm, 19mm, 13mm. Arctic White 1 pc. 10 pcs. ◆ All parts listed in Arctic White (AW) color. To order other colors substitute IW (Off White) or IG (Light Gray). Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. PAN-WAY Faceplates and Brackets for Italian Type Electrical Outlets For T-70, Twin -70, TE-70 Par t Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Mounting Bracket for Italian Type Outlets (for T-70/Twin-70/TE-70 Raceway)* T70MDB-X Bracket accepts VIMAR products (Italy) of the “idea” series. Mounts directly to T-70, Twin-70 Gray 10pcs. 100pcs. or TE-70 raceway. Italian Type Snap-On Electrical Faceplate* T70MDB-X T70PMAW-X Faceplate snaps over bracket frame to Arctic White 10pcs. 100pcs. mount to T-70, Twin-70 or TE-70 raceway or FAST-SNAP ™ Surface Mount Outlet Boxes. ◆ All parts listed in Arctic White (AW) color. To order other colors substitute IW (Off White) or IG (Light Gray). Contact factory for details. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. *Contact Panduit for availability and product offering. T70PM For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A6 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Australian Type Screw-On Electrical Outlet Part Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Australian Type Electrical Outlet* EJA15AW-X 15A two gang Australian standard outlet. Arctic White 10 pcs.100 pcs. ◆ All parts listed in Arctic White (AW) color. To order other colors substitute IW (Off White) or IG (Light Gray). Contact factory for details. ORDERING IN FORMAT ION: Order number of pieces required, in multiples of Standard Package. *Contact Panduit for availability and product offering. EJA15 PAN-WAY UK Style Electrical Modules and Faceplates Par t Number Description Color ◆ Std. Pkg. Qty. Std. Ctn. Qty. Electrical Modular Outlet EMG13AW-X 13A full size UK outlet module. Arctic White 10 pcs. 100 pcs. Two-Way Modular Switch EMG13 ETG16 ESG16 ETG16AW-X 16A two-way full module switch. Arctic White 10 pcs. 100 pcs. Double Pole Modular Switch ESG16AW-X 16A double pole full module switch. Arctic White 10 pcs. 100 pcs. Full size blank module fits UK T70BU2 faceplate. Arctic White 10 pcs. 100 pcs. Blank Module EBGAW-X EBG Snap-On Electrical Faceplate (for T-70/Twin-70/TE-70 Raceway) T70UMBAW-X Two gang faceplate accepts two full size Arctic White 10pcs. 100pcs. modules. Snaps onto T-70, Twin-70 or TE-70 raceway channel. For use with EMG13, ETG16, ESG16 and EBG modules. Hanging Box (for T-70/Twin-70/TE-70 Raceway) T70GB-X T70UMB T70GB Box snaps into raceway channel to contain wiring in multi-channel applications. Gray 10 pcs. 100 pcs. ◆ All parts listed in Arctic White (AW) color. To order other colors substitute IW (Off White) or IG (Light Gray). Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A7 NOTES For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) A8 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 & Twin-70 Non-Metallic Surface Raceways for Power and Communications Cabling (including Fiber Optic Cables) B PAN-WAY T-70 and Twin-70 plastic surface raceways are aesthetically designed multichannel systems. These systems can be used to route, conceal and protect power and data cables inside one raceway. Fittings and terminations are designed to maintain the TIA/EIA required 1" minimum bend radius of high T-70 Surface Raceway NEW! 8 & 10 Foot Lengths performance copper and Fiber-Optic cabling throughout the entire system. The two systems are tamper resistant yet allow the qualified installer access for moves, adds and changes. Twin-70 Surface Raceway NEW! 8 & 10 Foot Lengths pg. B7 pg. B15 • Compact design with capacity for routing power and/or communication cables to workstations • Inline or Offset termination configurations available • NEMA Standard Devices and 70mm Faceplates can be flush mounted within the channel • Two totally separate channels within one raceway with maximum capacity for trunking and routing power and communication cables to workstations • NEMA Standard Devices and 70mm Faceplates can be flush mounted within the channel • Independent access to power and communications cabling for added user safety • No boxes are required for mounting devices Panduit PAN-WAY T-70 & Twin-70 Raceways provide the following common benefits: • Attractive and complementary profiles for seamless transitions between systems • Power Rated to 600V (UL) meets new UL5A standards , 300V (CSA) meets CSA 22.2 No. 62-93 standards • Both raceways are part of the FIBER-SPEC™ System and are optimized for Fiber-Optic cabling • Fittings maintain the minimum 1" bend radius required under TIA/EIA 568-A and 569-A for high performance copper and Fiber Optic cabling systems • Covers and fittings are extremely tamper resistant • New! Snap-On Faceplates require less hardware for quick terminations and lower installed cost • Both systems use common components for installer convenience • Four standard colors available to complement any surrounding decor For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B1 PAN-WAY ™ PLASTIC SURFACE RACEWAY Table of Contents PAN-WAY ™ T-70 Page 1 2 3 4 Configurations. . . . . . . . . . . . . . . . . . . B4-B5 Raceway Base & Cover . . . . . . . . . . . . . . . . . . . . . . . . B7 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . B9-B11 PAN-WAY T-70 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B7-B8 PAN-WAY T-70 WORKSTATION OUTLET CENTER Offset Box . . . . . . . . . . . . . . . . . . . . . . . . .B8 ™ PAN-WAY Twin-70 1 2 3 4 Configurations. . . . . . . . . . . . . . . . . B12-B13 Raceway Base & Cover . . . . . . . . . . . . . . . . . . . . . . . B15 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . B17-B19 PAN-WAY Twin-70 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B16 PAN-WAY T-70 & Twin-70 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B20 T-70 Snap-On Fiber Spool Bracket . . . . . . . . . . . . . . B20 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B2 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 Raceway System T-70 CONFIGURATIONS T-70 Base page B7 1 2 3 4 T-70 Cover page B7 See page B4 thru B5 PAN-WAY Electrical Outlet page A4 PAN-WAY Snap-On Electrical/Communication Faceplates page A3 Fittings page B7 -B8 Standard Communication Module Frames page vii PAN-WAY Snap-On Communication Faceplate (with screw holes to mount a module frame) page A3 WORKSTATION OUTLET CENTER ™ page B8 Fittings page B7-B8 PAN-WAY Twin-70 Raceway System Twin-70 CONFIGURATIONS 1 2 3 4 See page B12 thru B13 Twin-70 Base page B15 Twin-70 Cover page B15 Standard Communication Module Frame page vii PAN-WAY Electrical Outlet page A4 PAN-WAY Snap-On Electrical/Communication Faceplates page A3 Fittings page B16 Fittings page B16 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B3 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 Raceway Configurations Base: pg. B7 Cover: pg. B7 Fittings: pg. B7-B8 Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). 1 PAN-WAY Snap-On Electrical/Communication Faceplates T 3 4 1 3 4 2 1 4 • Snap-On Faceplates provide a superior appearance • Can use most manufacturers’ communication module frames (see chart on page vii) 1 5 6 Inline Data & Power Inline Power Only Data Only 1 Data & Power Components Required Power On ly Data On ly 3 See Page X X X X X X X A3 vii A4 B20 B20 B7 2 Areas (in²) Inline Data & Power Data Only Power Only B 1.75 3.37 — Snap-On Electrical/C omm. Faceplate(s) (T70PG shown) 2. Standard Communication Module Frame X X 3. 4. PAN-WAY Electrical Outlet (ERU20 shown) Device Mounting Bracket (T 70D B-X shown) X 5. Hanging Box (T70HB3-X shown) 6. Divider Wall (T 70DW shown) X X PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) Inline 1 2 1 • Faceplate requires no device mounting bracket or hanging box • Can use most manufacturers’ communication module frames (see chart on page vii) 2 Inline Data Only Areas (in²) Data Only A — See Page 1. Snap-On Communication Faceplate (with screw holes to mount a module frame) (T70PGS shown) X A3 2. Standard Communications Module Frame X vii Components Required B 3.89 Note: For power and data applications use with configuration #1 above or w ith configuration #3 shown on next page Offset 6 4 2 3 1 4 6 5 2 • Offset configuration adds data capacity • Can use most manufacturers’ communication module frames (see chart on page vii) Offset Data & Power Components Required Data & Power 2 A .84 — 3.76 1. Data Only T-70 RACEWAY CONFIGURATIONS 2 See Page 1. Snap-On Communication Faceplate (w ith screw holes to mount a module frame) (T70PGS show n) X A3 2. Snap-On Electrical/C ommunication Faceplate (T 70PG shown) X A3 3. 4. Standard C ommunication Module Frame PAN-WAY Electrical Outlet (ERU20 shown) 5. Divider Wall (T 70DW shown) X X X vii A4 B7 6. WORKSTATION OUTLET CENTER ™ Offset Box (T 70WC2) X B8 1 3 Areas (in²) Offset Data & Power A 1.10 B 3.04 Note: Snap-On Faceplate Offset configuration shown requires Snap-On Electrical/ Communication Faceplate from Configuration #1 for power as noted in offset configuration (component #2) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B4 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 Raceway Configurations Base: pg. B7 Cover : pg. B7 Fittings: pg. B7-B8 Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). T Faceplates PAN-WAY U.S. Standard Screw-On Electrical/Communication 3 2 4 1 3 4 1 4 5 6 Inline Data & Power Data Only 3 1 Data On ly Inline Power Only • U.S. Standard Screw-On Electrical Faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) 1. U.S. Standard Screw-On Electrical/Comm. Faceplate(s) (CPG shown) X 2. Standard Communication Module Frame X 3. 4. PAN-WAY Electrical Outlet (ERU20 shown) Device Mounting Bracket (T70DB-X shown) 5. Hanging Box (T 70HB3-X shown) 6. Divider Wall (T 70DW shown) Components Required 2 Areas (in²) Inline Data & Power Data Only Power Only A .84 — 3.76 B 1.75 3.37 — 5 Offset 3 1 X See Page X X A3 X X X X X vii A4 B20 B20 B7 X X 2 • Offset configuration adds data capacity • Can use most manufacturers’ communication module frames (see chart on page vii) 3 5 4 Offset Data & Power Components Required D ata & Power 1 See Page 1. U.S. Standard Screw-On Electrical/C omm. Faceplate(s) (CPG shown) X A3 2. Standard Communication Module Frame 3. PAN-WAY Electrical Outlet (ERU20 shown) Divider Wall (T70DW shown) X X X vii A4 B7 WORKSTATION OUTLET CENTER ™ Offset Box (T70WC shown) X B8 2 Areas (in²) Offset Data & Power 4 A 1.10 B 3.04 4. 5. U.S. Standard Screw-On Communication Faceplates 1 3 1 Data Only • Uses most manufacturers’ NEMA standard 70mm communication faceplates • Panduit ® Styles available, for more information refer to page xii Components Requir ed 3 Areas (in²) Data Only A — B 3.74 1. U.S. Standard Screw -On Communication Faceplates 2. Device Mounting Bracket (T70DB-X shown) 3. Manufacturers’ inserts and/or communication modules Data On ly 2 See Page X X X — B20 — Note: For power and data applications use with configuration #3 above or with configuration #1 shown on previous page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B5 T-70 RACEWAY CONFIGURATIONS 1 Data & Power 2 Power On ly 3 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 Surface Raceway System Features NEW! The WORKSTATION OUTLET CENTER ™ Maximize the cabling capacity of PAN-WAY T-70 Raceway by using the new optional WORKSTATION OUTLET CENTER offset box. Two versions are available for PAN-WAY Snap-On Electrical/Communication Faceplates or U.S. Standard Screw-On Electrical/Com munication Faceplates. See Configuration 1 or 3 pg. B4-B5 Flush Mounted Applications U.S. Standard Screw-On Electr ical/ Com munication Faceplates and PAN-WAY Snap-On Electr ical/Communication Faceplates can be flush mounted into the T-70 channel to place power & data devices wherever needed. T-70 has adequate capacity for trunking applications See Configur ation 1 or 3 pg. B4-B5 Solution #2 — Example Installation 2 Using the PAN-WAY Snap-On Communication Faceplate (with screw holes to mount a module frame) Place module frame behind faceplate... Scr ew module frame and faceplate together... Snap faceplate to channel... Done! For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B6 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ T-70 Surface Raceway Base & Cover PAN-WAY Type T-70 Surface Raceway is an aesthetically designed, multi-channel system to route, protect and conceal data, voice, video, fiber-optic and power cabling. T-70 System Benefits: • Power rated to 600V(UL), 300V(CSA) meets new UL5A standard and CSA 22.2 No. 62-93 standards • Fittings maintain the TIA/EIA required 1" bend radius for Fiber-Optic and Category 5 cabling systems • Supplied with pre-punched mounting holes • Extremely tamper resistant Compatible with: — PAN-WAY Snap-On Faceplates — Any U.S. Standard Screw-On Electrical/Communication Faceplate(s) NEW Lengths! Std. Ctn. Part Qty. Number Part Number Std. Ctn. Qty. Colors◆ T-70 Raceway Base 8 ft. lengths A=5.15in² T70B 4.07" 1.77" 10 ft. lengths 48 ft. T70BIW10 60 ft. Off White T-70 raceway base in 8 or 10 ft. lengths. Supplied with pre-punched mounting holes every 8". T70BIW8 T-70 Raceway Cover T70CIW8 96 ft. T70CIW10 T-70 raceway cover in 8 or 10 ft. lengths. 120 ft. Off White T-70 Raceway Divider Wall T70DW8 96 ft. T70DW10 Gray ONLY Snaps onto rails in raceway base to create separate channels. Must use with wire retainers to ensure channel separation per UL/CSA. T70C 1.34" T70DW 120 ft. NOTE: Order raceway base and cover separately. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. .75" ORDERING INF ORMAT ION: Order number of feet required, in multiples of Standard Length Increment. Type T-70 Fittings T70BC**-X T70IC T70CC**-X T70OC Std. Pkg. Qty. Std. Ctn. Qty. Part Number Description Colors ◆ T70BCIW-X Base Coupler Fitting Off White 10 pcs. 100 pcs. T70CCIW-X Cover Coupler Fitting Off White 10 pcs 100 pcs. T70ICIW Inside Corner Fitting Off White 1 pcs. 10 pcs. T70OCIW Outside Corner Fitting Off White 1 pc. 10 pcs. T70RAIW Right Angle Fitting Off White 1 pc. 10 pcs. T70ECIW End Cap Fitting Conduit breakouts: ½" Off White 1 pc. 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. T70RA T70EC ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. Maintains TIA/EIA 568-A and 569-A minimum 1" cable bend radius For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B7 PAN-WAY ™ PLASTIC SURFACE RACEWAY Type T-70 Fittings (cont’d) T70T T70TDT T70TDC T70TDB T70EE T70TR T70TRC T70TRI Description Std. Pkg. Qty. Colors ◆ Tee Fitting 1 pc. Off White 10 pcs. T70TDT (Top Position) T-70 Raceway Divider Inserts (Power & T70TDC (Center Position) Data Applications). Separate power and T70TDB (Bottom Position) data within Tee Fitting when divider wall placed in top, center or bottom position T70EEIW Entrance End Fitting Conduit breakouts: ½", ¾", 1", 1¼" Entry from ceiling or wall. T70TRIW Transition Fitting to any LD Profile Raceway. Includes fitting for bend radius control. Maintains channel separation within T-70 raceway — Base & Cover T70TRCIW Transition Fitting to any LD Profile Raceway — Cover Only T70TRI Divided insert for T70 to LD2P10. Maintains channel separation within T70TR Fitting 1 pc. Part Number T70TIW Gray ONLY Std. Ctn. Qty. 10 pcs. 1 pc. Off White 10 pcs. 1 pc. Off White 10 pcs. 1 pc. Off White 10 pcs. 1 pc. Gray ONLY 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. T-70 Raceway Accessories available on pag e B20 Maintains TIA/EIA 568-A and 569-A minimum 1" cable bend radius Tee Insert Configurations — KEY — D ata Cabling Power Cabling Tee Inse rt D ivide r Wa ll T70TDT T70TDC T70TDB Divided Tee Inserts are used to separate power and data cabling for various tee configurations. Maintains 1" bend radius of data cables. PAN-WAY WORKSTATION OUTLET CENTER ™ Offset Box for T-70 Raceway NEW! Part Number Description Colors ◆ Std. Pkg. Qty. Std. Ctn. Qty. 1 pc. 10 pcs. 1 pc. 10 pcs. WORKSTATION OUTLET CENTER Offset Box — For U.S. Standard Screw-On Electrical/Communication Faceplates T70WC NEW! T70WCIW Two-piece box & bracket accept any NEMA standard 70mm faceplate with mounting hole widths of 3.28” (83.5mm). Off White WORKSTATION OUTLET CENTER Offset Box — For PAN-WAY Snap-On Electrical/Communication Faceplates T70WC2IW Two-piece box & bracket accept any standard electrical outlet. Accepts any PAN-WAY Snap-On Electrical/Communication Faceplates. Off White ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and T70WC2 The WORKSTATION OUTLET CENTER offset box places electrical and communications devices into a common area while maximizing the cabling capacity of the raceway channel. WH (White). C ontact factory for details. The WORKSTATION OUTLET CENTER offset box Snap-On Faceplate version provides the lowest installed cost by reducing hardware and labor. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B8 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for T-70 Raceway Use the wirefill configurations below along with the wirefill information contained on the next two pages as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Wirefill #1: T-70 Raceway with no devices A=.86 in ² FILL CAPACITIES A= 5.15 in ² A=1.72in ² Wirefill #2: Power & Data using Three Sided Hanging Box and Device Bracket Includes: Three sided Hanging Box, Divider Wall, Wire Retainer, Snap-On Electr ical/Communication Faceplate. Not shown for clarity: U.S. Standard Electrical Outlet, Standard Communication Module Frame and Communication Modules. A= 3.89 in² A= 3.37 in² Wirefill #3: Data Only using U.S. Standard Screw-On Electrical/Communication Faceplates Includes: Device Bracket, U.S. Standard Screw-On Electrical/ Communication Faceplate, Standard Communication Module Frame and Communication Modules. Wirefill #4: Data Only using Snap-On Communication Faceplates (with screw holes to mount a module frame) Includes: Snap-On Communication Faceplate (with screw holes to m ount a m odule frame), Standard Communication Module Frame and Com munication Modules A=.91 in² A= 2.67 in ² Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER™ Offset Box Includes: WORKSTATION OUTLET CENTER Offset Box, Divider Wall, Wire Retainer, Snap-On Electrical/ Communication Faceplate (with screw holes to mount a module fram e), Standard Com munication Module Frame and Communication Modules. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B9 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for T-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page B9. FILL CAPACITIES SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes ·Electrical MAX=60% wirefill—based on useful internal area and cable areas Fill Capacity Table for: ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP Electrical Cables Raceway Channel Wirefill Configurations See Fill # Voice Grade Cables Data Grade Cables AWG 24 AWG UTP CM/CMR 24 AWG UTP CM Cat. 5 4 pr 14 12 10 2 pr 3 pr 4 pr 25 pr THHN/T90 DIA.= 0.120 DIA.= 0.150 DIA.= 0.190 DIA.=0.422 DIA.=0.217 0.105 0.122 0.153 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 24 20 5 182 273 117 175 73 109 15 22 56 84 2A 14 11 7 30 46 19 29 12 18 2 4 9 14 2B ** ** ** 61 91 39 58 24 36 5 7 19 28 Wirefill #3: Data Only using U.S. Stand ard Screw-On Electrical/ Commu nication F acep lates 3 ** ** ** 119 178 76 114 47 71 9 14 36 54 Wirefill #4: Data Only using Snap-On Comm unication Facep lates (with screw holes to moun t mod ule frames) 4 ** ** ** 137 206 87 131 54 82 11 16 42 63 5A 14 11 7 32 48 20 31 12 19 2 3 9 14 5B ** ** ** 94 141 60 90 37 56 7 11 28 43 Wirefill #1: T70 with No Devices Wirefill #2: Power & Data using T hree Sid ed Hangin g Box & Device Bracket Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER ™ Offset Box NOTE: See p ag e xiv-xv for further explanation of wirefill data. ** Not power configuration Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP ·1A STP Data Grade Cables Raceway Channel Wirefill Configurations 24 AWG STP CM 22 AWG UTP CM 22 AWG STP CM 1A 22 AWG STP CM 25 pr 4 pr 25 pr 4 pr 25 pr 4 pr DIA.=0.512 DIA.=0.250 DIA.= 0.544 DIA.= 0.234 DIA.=0.635 DIA.=0.286 DIA.=0.430 See FILL FILL FILL FILL FILL FILL FILL Fill # SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 10 15 42 63 9 13 48 72 7 10 32 48 14 21 2A 2 3 7 11 1 2 8 12 1 2 5 8 2 4 2B 3 5 14 21 3 4 16 24 2 3 11 11 5 7 Wirefill #3: Data Only using U.S. Stand ard Screw-On Electrical/ Com munication Facep lates 3 6 9 27 41 5 8 31 46 4 6 20 31 9 13 Wirefill #4: Data Only using Snap-On Com munication Facep lates (with screw holes to moun t mod ule frames) 4 7 11 31 47 6 10 36 54 4 7 24 36 10 16 5A 1 2 7 11 1 2 8 12 1 1 5 8 2 3 5B 5 7 21 32 4 6 24 37 3 5 16 24 7 11 Wirefill #1: T 70 with No D evices Wirefill #2: Power & Data using T hree Sided Hangin g Box & Device Bracket Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER Offset Box NOT E: See page xiv-xv for further explanation of wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B10 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for T-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page B9. SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—based on useful internal area and cable areas Raceway Channel Wirefill Configurations See Fill # Coax Cables RG6/u RG11/u RG58/u RG59/u RG62A/u DIA.=0.270 DIA.=0.405 DIA.=0.193 DIA.=0.242 DIA.=0.242 FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 36 54 16 24 70 106 45 67 45 67 2A 6 9 3 4 12 18 7 11 7 11 2B 12 18 5 8 24 35 15 22 15 22 Wirefill #3: Data Only using U.S. Stand ard Screw-On Electrical/ Commu nication F aceplates 3 23 35 10 15 46 69 29 43 29 43 Wirefill #4: Data Only using Snap-On Comm unication Facep lates (with screw holes to moun t mod ule frames) 4 27 40 12 18 53 79 33 50 33 50 5A 6 9 2 4 12 18 7 11 7 11 5B 18 28 8 12 36 54 23 34 23 34 Wirefill #1: T70 with No Devices Wirefill #2: Po wer & Data using T hree Sid ed Hangin g Box & Device Bracket Wirefill #5: Po wer & Data using the WORKSTATION OUTLET CENTER ™ Offset Box FILL CAPACITIES Fill Capacity Table for: ·Coax Cables NOTE: See p ag e xiv-xv for further explanation of wirefill data. Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Raceway Channel Wirefill Configurations Wirefill #1: T 70 with No Devices Wirefill #2: Power & Data using T hree Sided Hangin g Box & Device Bracket Fiber Optic Cables (62.5/125mm) Signal Cables 2 Strand 4 Strand 6 Strand 18AWG 20 AWG 22 AWG 24 AWG DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 DIA.=0.057 DIA.=0.050 DIA.=0.044 See FILL FILL FILL FILL FILL FILL FILL Fill # SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 86 129 86 129 60 89 602 904 602 904 1050 1575 1355 2033 2A 14 21 14 21 10 15 140 210 140 210 175 263 226 340 2B 29 43 29 43 20 30 279 419 279 419 351 526 453 679 Wirefill #3: Data Only using U.S. Stand ard Screw-On Electrical/ Com munication Facep lates 3 55 83 55 83 38 58 393 590 527 791 685 1028 885 1328 Wirefill #4: Data Only using Snap-On Com munication Facep lates (with screw holes to moun t mod ule frames) 4 64 96 64 96 44 67 454 681 609 913 791 1187 1022 1533 5A 15 22 15 22 10 15 106 160 143 214 186 279 240 360 5B 44 66 44 66 30 46 312 468 418 628 544 816 702 1054 Wirefill #5: Power & Data using the WORKSTATION OUTLET CENTER Offset Box NOTE: See page xiv-xv for further explanation of wirefill data. Raceway Cutting Instructions: For small quantities, use a fine tooth handsaw. For larger quantities use a plastic cutting saw blade for clean, burrfree cuts. Recommend: Carbide 80T or 100T;.090" thickness,.125" kerf. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B11 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Twin-70 Raceway Configurations Twin Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). 1 70 PAN-WAY Snap-On Electrical/Communication Faceplates Twin-70 RACEWAY CONFIGURATIONS 4 2 1 3 4 4 Data & Power 2 1 2 4 Data Only • Snap-On Faceplates provide a superior appearance (No screws required). • Can use most manufacturers’ communication module frames (see chart on page vii) 3 Areas (in²) Data & Power Data Only A 3.32 — B 2.80 2.80(x2) Data & Power 2 Power Only Components Required Data Only 1 See Page X X X A3 X X X X X vii A4 B20 1. Snap-On Electrical/C ommunication Faceplate(s) (T 70PG shown) 2. 3. Standard Communication Module Frame PAN-WAY Electrical Outlet (ERU20 shown) X 4. Device Mounting Bracket (T 70D B-X shown) X PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) 2 1 • Faceplate requires no device mounting bracket or hanging box • Can use most manufacturers’ communication module frames (see chart on page vii) 1 Data & Power 2 Data Only 2 Base: pg. B15 Cover: pg. B15 Fittings: pg. B16 See Page 1. Snap-On Communication Faceplate (with screw holes to mount a module frame) (T70PGS shown) X A3 2. Standard Communication Module Frame X vii Components Required Ar eas (in²) Data Only A 3.32 B 3.32 Note: For power application shown add the power only components from configuration #1 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B12 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Twin-70 Raceway Configurations Twin Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 1 3 4 4 2 Data Only 2 4 See Page X X X A3 X X X X X vii A4 B20 1. U.S. Standard Screw-On Electrical/Comm. Faceplate(s) (CPG shown) 2. 3. Standard Communication Module Frame PAN-WAY Electrical Outlet (ERU20 shown) X 4. Device Mounting Bracket (T70DB-X shown) X 1 A 3.32 — • U.S. Standard Screw-On Electrical Faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) Components Required 3 Ar eas (in²) Data & Power Data Only 4 B 2.80 2.80 (x2) U.S. Standard Screw-On Communication Faceplates 2 3 1 • Uses most manufacturers’ NEMA standard 70mm communication faceplates (see chart on page vii) • Panduit ® Styles available, for more information refer to page xii Components Required 3 Areas (in²) Data Only A 3.32 B 3.17 1. U.S. Standard Screw-On Communication Faceplates 2. Device Mounting Bracket (T 70DB-X shown) 3. Manufacturers’ inserts and/or modules Data On ly Data & Power 1 See Page X X X A3 B20 — Note: For power application shown add the power only components from configuration #3 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B13 Twin-70 RACEWAY CONFIGURATIONS Data & Power 2 1 Data & Po wer 2 Po wer Only 4 Data Only 3 Base: pg. B15 Cover: pg. B15 Fittings: pg. B16 70 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Twin-70 Surface Raceway System Features NEW! See Configuration 1 or 3 pg. B12 - B13 pg. B16 Extreme tam per-r esistance with a large capacity makes Twin-70 raceway ideal for routing and maintaining power and data into computing intense environments such as media centers and computer labs. T70PG Page A3 Maximiz es safety by maintaining total separation of data and power cabling throughout the entir e raceway system. Enter the raceway from a ceiling drop or “thru-wall” with the Entrance End Fitting See Configur ation 1 or 3 pg. B12 - B13 Both U.S. Standard Screw-On Faceplates and PAN-WAY Snap-On Electrical/ Communication Faceplates are flush mounted into the Twin-70 channel to place power & data devices wherever needed. PAN-WAY T-70 Surface Raceway is fully compatible with New PAN-WAY Twin-70 Surface Raceway to drop power & communications cabling into the work environment. NEW! pg. A3 Terminations are a Snap! New PAN-WAY Snap-On Electrical/Communication Faceplates place devices anywhere in the raceway, quickly! Twin -7 0 ha s ad ded cap acity fo r tru nk ing a pp lication s For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B14 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Twin-70 Surface Raceway Base & Cover PAN-WAY Type Twin-70 Surface Raceway is an aesthetically designed system featuring two separate dedicated channels that can form up to four total channels to route, protect and conceal data, voice, video, fiber-optic and power cabling. Twin-70 System Benefits: • Power rated to 600V(UL), 300V(CSA) m eets new UL5A standard and CSA 22.2 No. 62-93 standards • Separate channels allow independent access to power and communication cabling throughout the entire system • Fittings maintain the TIA/EIA required 1" bend radius for Fiber-Optic and Category 5 cabling systems • Extremely tamper resistant • Supplied with pre-punched mounting holes Compatible with: —PAN-WAY Snap-On Faceplates —Any U.S. Standard Screw-On Electrical/Communication F aceplate(s) Par t Number NEW Lengths! Std. Ctn. Qty. Std. Ctn. Qty. Par t Number Colors◆ Twin-70 Raceway Base 8 ft. lengths 10 ft. lengths T702BIW8 24 ft. T702BIW10 30 ft. Off White Twin-70 raceway base in 8 or 10 ft. lengths. Supplied with pre-punched mounting holes every 8". A=4.59in² A=4.59in ² T702B 7.23" 1.77" T-70 Raceway Cover T70CIW8 96 ft. T70CIW10 120 ft. T-70 or Twin-70 raceway tamper resistant cover in 8 or 10 ft. lengths. NOTE: Two feet of cover needed for every foot of base. Off White T-70 Raceway Divider Wall T70DW8 Gray ONLY Snaps onto rails in raceway base to create separate channels. Must use with wire retainers to ensure channel separation per UL/CSA. T70C 1.34" T70DW .75" 96 ft. T70DW10 120 ft. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. NOTE : Order raceway base and cover separately. ORDERING INF ORMATION: Order number of feet required, in multiples of Standard Length Increment. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B15 PAN-WAY ™ PLASTIC SURFACE RACEWAY Type Twin-70 Fittings T702BC**-X T702OC Std. Ctn. Qty. Description Colors ◆ T702BCIW-X Base Coupler Fitting Off White 10 pcs. 100 pcs. T70CCIW-X Cover Coupler Fitting Off White 10 pcs. 100 pcs. T702ICIW Inside Corner Fitting Off White 1 pcs. 10 pcs. T702OCIW Outside Corner Fitting Off White 1 pc. 10 pcs. T702RAIW Right Angle Fitting Off White 1 pc. 10 pcs. T702TRIW Transition Fitting — To T-70 Off White Raceway Transition Fitting — To any LD Off White Profile Raceway Divided Insert for T702 to T70 or Gray ONLY T702 to LD profile. Maintains channel separation within T702TR or T702TRL fitting. Tee Fitting Off White 1 pc. 5 pcs. 1 pc. 5 pcs. 1 pc. 5 pcs. 1 pc. 5 pcs. Entrance End Fitting Conduit breakouts: ½",¾", 1", 1¼" Entry from ceiling or wall. End Cap Fitting Conduit breakouts: ½" Off White 1 pc. 5 pcs. Off White 1 pc. 10 pcs. T70CC**-X T702IC T702TRLIW T702TRI T702TIW T702RA Std. Pkg. Qty. Par t Number T702TR T702EEIW T702ECIW ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. T702TRL T702TRI ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. Maintains T IA/EIA 568-A and 569-A minimum 1" cable bend radius T702T T702EE T702EC For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B16 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for Twin-70 Raceway Use the wirefill configurations below along with the wirefill information contained on the next two pages as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. FILL CAPACITIES A= 4.59 in² A= 2.05 in² A= 1.43 in² Wirefill #1: Power & Data with No Terminations A= 2.80 in² Wirefill #2: One Twin-70 Channel with No Devices A= 3.32 in² Wirefill #3: Data Only using Device Bracket & U.S. Standard Screw-On Faceplates Wirefill #4: Power using Device Bracket & U.S. Standard Screw-On Faceplates Includes: Device Bracket, U.S. Standard Scr ew-On Electrical/Com munication Faceplate, Standard Communication Module Fr ame and Communication Modules Includes: Device Bracket, U.S. Standard Screw-On Electrical/Com munication Faceplate and U.S. Standard Electrical Outlet A= 2.33 in² A= 3.32 in² Wirefill #5: Data Only using Snap-On Electrical/Communication Faceplates (with screw holes to mount a module frame) Wirefill #6: 20A TVSS Rectangular Outlet using Device Bracket & Snap-On Electrical/ Communication Faceplate Includes: Snap-On Communication Faceplate (with screw holes to mount a module frame), Standard Communication Module Frame and Communication Modules Includes: Device Bracket, Snap-On Electrical/ Communication Faceplate and 20A TVSS Rectangular Outlet For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B17 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for Twin-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page B17. FILL CAPACITIES SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—based on useful internal area and cable areas Fill Capacity Table for: ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP ·Electrical Electrical Cables Voice Grade Cables Data Gr ade Cables AWG 24 AWG UTP CM/CMR 24 AWG UTP CM Cat. 5 4 pr 12 10 2 pr 3 pr 4 pr 25 pr THHN/T90 DIA.= 0.120 DIA.= 0.150 DIA.= 0.190 DIA.=0.422 DIA.=0.217 0.105 0.122 0.153 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 14 Raceway Channel Wirefill Configurations See Fill # Wirefill #1: Power & Data with No Terminations 1A n/a n/a n/a 73 109 46 70 29 43 6 9 22 33 1B 16 16 15 51 76 32 49 20 30 4 6 15 23 Wirefill #2: On e Twin-70 Chann el with No Devices 2 n/a n/a n/a 162 244 104 156 65 97 13 20 50 75 Wirefill #3: Data On ly u sin g Device Bracket & U.S. Stand ard Screw-On Facep lates 3 ** ** ** 99 148 63 95 39 59 8 12 30 45 Wirefill #4: Power u sing Device Bracket & U.S. Standard Screw-On F aceplates 4 15 13 13 117 176 75 113 47 70 9 14 36 54 Wirefill #5: Data On ly u sin g Snap-On Electrical/Commu nication Faceplates (with screw holes to m ount a m odule frame) 5 ** ** ** 117 176 75 113 47 70 9 14 36 54 Wirefill #6 : 20A T VSS Rectang ular Outlet using Device Bracket & Snap-On Electrical/Commu nication facep late Facep late 6 16 16 14 82 124 53 79 33 49 7 10 25 38 NOT E: See page xiv-xv for further explanation of wirefill data. ** Not power configuration Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP ·1A STP Data Grade Cables Raceway Channel Wirefill Configurations See Fill # 24 AWG STP CM 22 AWG UTP CM 22 AWG STP CM 1A 25 pr 4 pr 25 pr 4 pr 25 pr 4 pr 22 AWG STP CM DIA.=0.512 DIA.=0.250 DIA.= 0.544 DIA.= 0.234 DIA.=0.635 DIA.=0.286 FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1A 4 6 17 25 4 5 19 29 3 4 13 19 6 8 1B 3 4 12 17 2 4 13 20 2 3 9 13 4 6 Wirefill #2: One Twin -70 Channel with No Devices 2 9 13 37 56 8 12 43 64 6 9 29 43 13 19 Wirefill #3: Data Only using Device Bracket & U.S. Standard Screw-On Faceplates 3 5 8 22 34 4 7 26 39 3 5 17 26 7 11 Wirefill #4: Power using Device Bracket & U.S. Standard Screw-On Faceplates 4 6 10 27 41 6 9 31 46 4 6 21 31 9 14 Wirefill #5: Data Only using Sn ap -On Electrical/Co mmun icatio n Faceplates (with screw h oles to mou nt a mo dule fram e) 5 6 10 27 41 6 9 31 46 4 6 21 31 9 14 Wirefill #6: 20A TVSS Rectangu lar Outlet u sin g Device Bracket & Sn ap-On Electrical/Co mmun icatio n faceplate Faceplate 6 5 7 19 28 4 6 22 33 3 4 15 22 6 10 Wirefill #1: Power & Data No Terminatio ns NOT E: See page xiv-xv for further explanation of wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B18 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for Twin-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page B17. SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—based on useful internal area and cable areas Raceway Channel Wirefill Configurations Wirefill #1: Power & Data No Termin ations See Fill # FILL CAPACITIES Fill Capacity Table for: ·Coax Cables Coax Cables RG6/u RG11/u RG58/u RG59/u RG62A/u DIA.=0.270 DIA.=0.405 DIA.=0.193 DIA.=0.242 DIA.=0.242 FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1A 14 21 6 10 28 42 18 27 18 27 1B 10 15 4 7 20 29 12 19 12 19 Wirefill #2: One Twin-70 Ch an nel with No Devices 2 32 48 14 21 63 94 40 60 40 60 Wirefill #3: Data Only using Device Bracket & U.S. Stan dard Screw-On Faceplates 3 19 29 8 13 38 57 24 36 24 36 Wirefill #4: Power using Device Bracket & U.S. Stand ard Screw-On Facep lates 4 23 35 10 15 45 68 29 43 29 43 Wirefill #5: Data Only using Snap-On Electrical/Comm unication Facep lates (with screw holes to moun t a modu le frame) 5 23 35 10 15 45 68 29 43 29 43 Wirefill #6: 20A TVSS Rectan gular Outlet using D evice Bracket & Snap-On Electrical/Comm unication facep late Faceplate 6 16 24 7 11 32 48 20 30 20 30 NOTE: See page xiv-xv for further explanation of wirefill data. Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Raceway Channel Wirefill Configurations See Fill # Fiber Optic Cables (62.5/125mm) Signal Cables 2 Strand 4 Strand 6 Strand 18AWG 20 AWG 22 AWG 24 AWG DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 DIA.=0.057 DIA.=0.050 DIA.=0.044 FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1A 34 51 34 51 24 36 240 360 322 482 418 627 540 809 1B 24 36 24 36 17 25 167 251 224 336 291 437 376 565 Wirefill #2: One Twin-70 Channel with No D evices 2 76 115 76 115 53 80 537 805 720 1080 936 1403 1208 1812 Wirefill #3: Data Only using Device Bracket & U.S. Standard Screw-On Faceplates 3 46 69 46 69 32 48 327 491 438 658 570 855 736 1104 Wirefill #4: Power using Device Bracket & U.S. Stan dard Screw-On Faceplates 4 55 83 55 83 38 58 388 583 521 781 677 1015 874 1311 Wirefill #5: Data Only using Snap -On Electrical/Co mmunicatio n Faceplates (with screw ho les to mou nt a mod ule frame) 5 55 83 55 83 38 58 388 583 521 781 677 1015 874 1311 Wirefill #6: 20A TVSS Rectangu lar Outlet usin g Device Bracket & Snap -On Electrical/Co mmunicatio n faceplate Faceplate 6 39 58 39 58 27 40 273 409 365 548 475 712 613 920 Wirefill #1: Power & Data No Termination s N OTE: See page xiv-xv for further explanation of wirefill data. Raceway Cutting Instructions: For small quantities, use a fine tooth handsaw. For larger quantities use a plastic cutting saw blade for clean, burrfree cuts. Recommend: Carbide 80T or 100T; .090" thickness, .125" kerf. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B19 PAN-WAY ™ PLASTIC SURFACE RACEWAY Type T-70 & Twin-70 Raceway Accessories Part Number Std. Pkg. Qty. Std. Ctn. Qty. Description Color Used to mount NEMA standard single gang electrical outlets and communication devices with either screw-on or snap-on single gang faceplates. Gray 10 pcs. 100 pcs. Used to mount NEMA standard single gang electrical outlets and devices with either screw-on or snap-on single gang faceplates when there are communications cables in the raceway. Gray 10 pcs. 100 pcs. Used to mount NEMA standard single gang electrical outlets and devices with either screw-on or snap-on single gang faceplates when there are communications cables in the raceway. No break-outs are required. Low profile increases capacity in raceway. For use with T70 raceway only. Gray 10 pcs. 100 pcs. Holds wires in place. Will not interfere with cover installation. Gray 10 pcs. 100 pcs. — 10 pcs. 100 pcs. Device Mounting Bracket T70DB-X T70HB-X T70DB-X Hanging Box T70HB-X T70HB3-X T70WR-X Three Sided Hanging Box T70HB3-X Wire Retainer T70S-X T70WR-X Surface Mount Box Spacer Plate T70S-X Spacer plate is used to mount a CBX4 Surface Mount Box onto the Device Bracket or Hanging Box shown above. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. U sin g the sp acer p late a CB X4 b ox c an b e m o un ted o nto Twin -7 0 or T-7 0 raceway. T he CB X4 bo x fea tu res a fibe r sp o ol for m an agin g fib er op ti c ca ble s lack. N ote: F ibe r sp oo l op tio n al. No t n eces sary fo r T -70 or Twin -70 rac eway. T-70 Snap-On Fiber Spool Bracket NEW! Par t Num ber Description Color Std. Std. Pkg. Ctn. Qty. Qty. T-70 Snap-On Fiber Spool Bracket T70FSB T70SFB • Brackets are adjustable for slack length • Maintains TIA/EIA 568-A and 569-A minimum 1" cable bend radius Fiber spool bracket that snaps onto base of T-70. Provides method to contain 1m or more of fiber slack and provides strain relief. Maintains 1" bend radius for fiber optic cabling. Bracket distance can be adjusted to fit the length of slack required. Gray 2 pcs. 50 pcs. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. NOTE: Can only be used with T-70 base. Contact Panduit for availability. Use th e T7 0FSB wi th T-70 raceway to co ntain 1m.o r mo re o f fib er slack and m ain tain a 1" cabl e be nd radi us. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) B20 C PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Raceways PAN-WAY LD Profile Surface Raceways provide a complete system for routing and protecting premise cabling systems. The five different LD profile raceway types have unique features that will match the raceway to the specific Type LDP • Extremely tamper resistant latch design for power & fiber-optic applications • Excellent for school/university applications • Hinge provides exceptional strength during impact & cutting needs of many different power and/or communications cabling applications. A choice of standard low voltage, TIA/EIA 1" bend radius control, power rated and multi-channel fittings are available. Type CD • Two piece design —base & cover • Two base styles: –Adhesive Backed (smooth surfaces) –Screw Mounted Metal Bases (irregular surfaces) Type LD • Wires are laid in instead of pulled through for quick & easy installations • Hinge provides exceptional strength during impact & cutting • Fast & easy installations • New! 8 & 10 foot lengths for select styles of LD profile raceways Type LD2P • Multi-channel raceway routes power & data together • Excellent for office environments • Extremely tamper-resistant • Full complement of fittings, boxes & faceplates Type LDS • Non-latching design is economical with unmatched tamper resistance • Excellent for safety sensitive devices such as pay phones or security systems • Bendable in low voltage applications to route around and over obstructions For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C1 PAN-WAY ™ PLASTIC SURFACE RACEWAY Table of Contents Page PAN-WAY Type LDP Surface Raceway ™ Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . C10 Configurations . . . . . . . . . . . . . . . C6-C7 1 2 3 4 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . C17-C18 PAN-WAY Type LDS Surface Raceway Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . C11 Configurations . . . . . . . . . . . . . . . C6-C7 1 2 3 4 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . C17-C18 PAN-WAY Type LD Surface Raceway Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . C12 Configurations . . . . . . . . . . . . . . . C6-C7 1 2 3 4 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . C17-C18 PAN-WAY Type CD Surface Raceway Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . C13 Configurations . . . . . . . . . . . . . . . C6-C7 1 2 3 4 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . C17-C18 PAN-WAY Type LDP, LDS, LD & CD Fittings Standard Fittings. . . . . . . . . . . . . . . . . . . . . . . . . . . . C14 1" Bend Radius Fittings . . . . . . . . . . . . . . . . . . . . . . C14 600V Power Rated Fittings . . . . . . . . . . . . . . . . . . . . C15 PAN-WAY Type LD2P10 Surface Raceway Multi-Channel Surface Raceway . . . . . . . . . . . . . . . . C16 Multi-Channel Fittings . . . . . . . . . . . . . . . . . . . . . . . . C16 Configurations . . . . . . . . . . . . . . . . C6-C7 1 2 3 4 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . .C17-C18 NEW! Additional Related Products PAN-WAY Electrical Outlets . . . . . . . . . . . A4 PAN-WAY Faceplates . . . . . . . . . . . . . . A3-A4 PAN-WAY Surface Mount Outlet Boxes . . . . . . . . . . . . . . E3-E5 PAN-WAY Accessories . . . . . . . . . . . . . . . . . H1 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C2 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Non-Metallic Raceways Data Only—Roadmap SNAP-ON FACEPLATES APPLICABLE RACEWAYS LDP10 pg. C10 (or other applicable raceways) PAN-WAY Snap-On Electrical/Communication Faceplates (with holes to mount a module frame) pg. A3 FAST-SNAP ™ Surface Mount Outlet Boxes pg. E3 LD pg. C12 LDS pg. C11 CD pg. C13 CONFIGURATIONS 1 Standard Communication Module Frame pg. vii 1" Bend Radius Fittings for TIA/EIA Compliance pg. C14 LDP pg. C10 2 See page C6 thru C7 LD5 pg. C12 (or other applicable raceways) SCREW-ON FACEPLATES APPLICABLE RACEWAYS LDP pg. C10 LD pg. C12 LDS pg. C11 CD pg. C13 CONFIGURATIONS 3 LD10 pg. C12 (or other applicable raceways) PAN-WAY Double Gang Surface Mount Outlet Boxes (3 styles available) pg. E3 - E5 PAN-WAY Screw-On Electrical/Communication Faceplates pg. A3 4 See page C6 thru C7 PAN-WAY Single Gang Surface Mount Outlet Boxes (7 styles available) pg. E3 thru E5 LDP5 pg. C10 (or other applicable raceways) Standard Communication Module Frame pg. vii 1" Bend Radius Fittings for TIA/EIA Compliance pg. C14 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C3 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Non-Metallic Raceways Power Only—Roadmap SCREW-ON FACEPLATES APPLICABLE RACEWAYS LDP pg. C10 LDP10 pg. C10 (or other applicable raceways) LDS pg. C11 CONFIGURATIONS PAN-WAY Double Gang Surface Mount Outlet Box pg. E3 - E5 3 PAN-WAY Screw-On Electrical/Communication Faceplates pg. A3 4 See page C6 thru C7 NEMA Standard Rectangular Electrical Outlet pg. A4 Power Rated Fittings pg. C15 OPTIONAL BOX STYLES PAN-WAY 20A Surface Mount Outlet Box with 20A Electrical Outlet (also available in 106 duplex style) pg. A4 LDP5 pg. C10 (or other applicable raceway) PAN-WAY Power Source Surface Mount Outlet Box pg. E4 Power Rated Fittings pg. C15 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C4 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Non-Metallic Raceways Data & Power—Roadmap SNAP-ON FACEPLATES APPLICABLE RACEWAYS LD2P pg. C16 LD2P10 pg. C16 CONFIGURATIONS FAST-SNAP ™ Double Gang Surface Mount Outlet Box pg. E3 1 NEMA Standard Duplex Electrical Outlet pg. A4 Standard Communication Module Frame pg. vii 2 See page C6 thru C7 PAN-WAY Snap-On Electrical/Communication Faceplates (with screw holes to mount a module frame) pg. A3 PAN-WAY Snap-On Electrical/Communication Faceplates pg. A3 - A4 Multichannel 1" Bend Radius Control Fittings pg. C14 SCREW-ON FACEPLATES APPLICABLE RACEWAYS LD2P pg. C16 LD2P10 pg. C16 PAN-WAY Double Gang Surface Mount Outlet Box with Divider (JBP2D) pg. E4 CONFIGURATIONS 3 4 See page C6 thru C7 PAN-WAY Double Gang Screw-On Electrical/Communication Faceplates pg. A3 - A4 NEMA Standard Rectangular Electrical Outlet pg. A4 PAN-WAY Power Rated Single Gang Surface Mount Outlet Box (JBP1) pg. E4 Standard Communication Module Frame pg. vii PAN-WAY Divided Single Gang Surface Mount Outlet Box (JBP1D) pg. E4 Multichannel 1" Bend Radius Control Fittings pg. C14 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C5 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Raceway Configurations Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V) in horizontal applications. PAN-WAY Snap-On Electrical/Communications Faceplates 5 Data & Power • Snap-On Faceplates provide a superior appearance • FAST-SNAP ™ Boxes snap together for quick installation • Data and Power box is divided to maintain separation 3 Components Required 4 Data & Power (Must be used with LD2P10 raceway) LDP/LD/LDS or CD Raceway 2. LD2P10 Multichannel Raceway 3. Snap-On Electrical/Communication Faceplate(s) 4. NEMA Standard Duplex Outlet See Page X X X X C10-C13 C16 A3 A4 E3 X X 5. Double Gang FAST-SNAP Outlet Box X Note: For data area(s) and fill cap acity informatio n seepage C17-C18 PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) 4 4 7 8 4 5 6 3 8 5 5 Data & Power Data Only (B) Data Only (A) 1 • Snap-On Faceplates provide a superior appearance • Can use most manufacturers’ communication module frames (see chart on page vii) • FAST-SNAP ™ Boxes snap together for quick installation • Data and Power box is divided to maintain separation 5 4 7 Components Requir ed Data Only (A) 1 4 See Page X X C10-C13 C16 A3 A3 1. LDP/LD/LDS or CD Raceway 2. 3. LD2P10 Multichannel Raceway Snap-On Electrical/Communication Faceplate(s) 4. Snap-On Electrical/Communication Faceplate(s) (with screw holes to mount a module frame) X X X 5. Standard Communication Module Frame(s) X X 6. NEMA Standard Duplex Outlet X X 8 5 Data & Po wer 2 1. Data & Power 2 5 Data (A) Data (B) 3 Data (B ) LD PROFILE RACEWAY CONFIGURATIONS 4 Data (A ) 1 X X Single Gang FAST-SNAP Outlet Box X 8. Double Gang FAS T-SNAP Outlet Box X Note: For data area(s) and fill capacity information see pag e C17-C 18 7. X vii A4 E3 E3 Data Only (B) 2 8 4 3 5 6 Data & Power (Must be used with LD2P10 raceway) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C6 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Raceway Configurations Cont’d PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 3 5 4 4 5 6 7 9 4 8 6 Power Only Data & Power Data & Power Power On ly Components Required 5 Data On ly • Standard US screw-on electrical faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii ) 1 See Page 5 1. LDP/LD/LDS or CD Raceway 2. LDP or LDS Raceway 3. LD2P10 Multichannel Raceway 4. U.S. Standard Screw-On Electrical/Communication Faceplate(s) (single or double gang available) X 5. Standard Communication Module Frame(s) X 6. NEMA Standard Rectangular Outlet(s) 2 7. Low Voltage Surface Mount Outlet Boxes (7 styles to choose from) 4 8. Power Rated Surface Mount Outlet Boxes (5 styles to choose from) 9. Divided Power Rated Surface Mount Outlet Boxes (3 styles to choose from) Data Only 4 6 X C10-C13 X C10-C11 X C16 X X A3 X X X vii A4 E3 X E4 X E5 X Note: F or data area(s) and fill capacity info rm ation see page C17-C18 6 Optional for Power NEW! Power Only • Surface Mount Outlet Box includes box, 20A outlet and cover in duplex rectangular or 106 styles 3 Power Only 4 See Page 1. LDP or LDS Raceway X C10-C11 2. 20A Low Profile Rectangular or 106 Style Surface Mount Outlet Boxes (include box, 20A outlet & self cover) X A4 Components Required 5 6 Data & Power 4 U.S. Standard Screw-On Communication Faceplates 2 3 4 2 3 Data On ly 1 • Uses selected manufacturers’ standard communication faceplates • Panduit ® Styles available, for more information refer to page xii See Page 1. LDP/LD/LDS or CD Raceway X C10-C13 2. Most Mfg. U.S. Screw-On Standard Communication Faceplates (see page listed for Panduit styles) X — 3. Manufacturers’ inserts and/or modules X — 4. Low Voltage Surface Mount Outlet Box (7 styles to choose from) X E3 Components Requir ed 4 Note: For data area(s) and fill capacity in formation seepag e C 17 -C18 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C7 LD PROFILE RACEWAY CONFIGURATIONS Data Only PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Raceways—System Features See Configurations 2 - 4 on previous page LDP Raceway pg. C10 LDP raceway is part of our FIBER-SPEC r aceway family. FIBER-SPEC raceways are designed specifically for high performance structured cabling systems. They provide the TIA/EIA required bend radius, security/tamper resistance, and access to the required one meter of fiber slack. ™ JBP1 pg. E4 JB1D pg. E3 1" Bend Radius Fittings pg. C14 Th e stan dard de pth p ower s urfa ce m ou nt ou tlet b ox provid es a du rabl e, secu re way o f m ou nting ele ctrica l devi ces an d face plates. Th e de ep o ne-pi ece su rface m ou n t ou tlet b ox prov ides th e extra sp ace n eed ed to mai ntain th e T IA/EIA requ ired be nd radi us. Th e u niq u e righ t a ng le en tran ce e nd fitti ng allows cable s to en ter th ro ug h th e wall in to th e raceway, while main tainin g th e T IA/EIA requ ired be nd radiu s. LD2P Raceway pg. C16 NEW! See Configurations 2 - 4 on previous page N ew! m ulticha nn el L D2P10 is a co nve nien t way to rou te b o th po wer and d ata cabl es to a com p uter work station . It prov ides lowest in stall ed c ost by e limi nating the n eed for m ultipl e bo xes an d face plates. Th e New! Do ub le Gan g D ivid ed Surface Mo u nt Ou tl et B oxes wh en us ed with m o du le frame s pla ce data & po we r ou tlets at th e sa me conv enie nt loca tio n. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C8 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ LD Profile Raceways—System Features 1" Bend Radius Fittings C14 LDS Raceway pg. C11 The Drop Ceiling/Entrance End fitting allows for a transition out of the ceiling and into any LD Profile raceway (LDS5 shown) without having to cut the metal ceiling suppor t. LD Profile raceways may be used in a variety of applications including fire alarms, security, emergency lighting and power. (LDS3 & LDS5 raceway shown) The one-piece Type LDS raceway is bendable and allows you to get around obstacles such as conduit, existing raceway, mouldings, and offsets in the wall (in low voltage applications.) LDS has the same external dimensions as all the LD Profile raceways and works with the same fittings. This allows for the transition to LDS, bend around the object, then transition back to LD, LDP, or CD. LDS Raceway pg. C11 The LDS can be transitioned to and from LDP (as shown above) to get around obstacles on the wall. See Configuration 3 pg. C7 STANDARD EQUIPMENT! As with all Panduit Raceways standard devices and faceplates are readily accepted. See Configuration 2 pg. C6 SNAP-ON SOLUTIONS! Our New FAST-SNAP ™ Sur face Mount Outlet Boxes accept PAN-WAY Snap-On Faceplates to provide lowest installed cost. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C9 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Type LDP Surface Raceway PAN-WAY Type LDP Surface Raceway is a single channel raceway designed to route, protect and conceal data, voice, video, fiber-optic or power cabling. Type LDP Raceway Benefits: • Power rated to 600V(UL), 300V(CSA). Meets New! UL5A and CSA 22.2 No. 62-93 standards • Extremely tamper resistant latch for School & University applications • One-piece hinged design allows cables to be laid in • Factory applied adhesive backing speeds installation • NEW! Now FT-4 Rated for Canada NEW Sizes! Std. Ctn. Qty. Part Number A=.21in ² Par t Number 8 ft. lengths LDP3 .46" Std. Ctn. Qty. Colorsu 10 ft. lengths LDP3—Surface Raceway LDP3 .77" LDP3IW8-A 160ft. LDP3IW10-A 200ft. Off White 160ft. LDP5IW10-A 200ft. Off White 160ft. LDP10IW10-A 200ft. Off White LDP5—Surface Raceway A=.38in² LDP5 LDP5IW8-A .60" LDP10—Surface Raceway LDP10IW8-A 1.00" LDP5 A=.98in² LDP10 1.51" Tamper resistant one-piece latching surface raceway. Supplied with pre-applied adhesive backed tape. NOTE: LDP Raceway requires screw mounting if it is being used for power cabling applications. u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), .86 and BR (Brown). Contact factory for details. ORDING INF ORMATION: Order number of feet required, in multiples of Standard Length Increment. See page C14-C15 for fittings LDP10 LD/LDP/LD2P Raceway Installation Tool NEW! Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. LDP Raceway Installation Tool LDW3-V LDW5-V LDW10-V Optional installation tool for use with Type LD3/LDP3 raceways. Optional installation tool for use with Type LD5/LDP5 raceways. Optional installation tool for use with Type LD10/LDP10/LD2P10 raceways. Serves as guide for drill 5 pcs. 50 pcs. bit in screw mount applications. Holds LD/ 5 pcs. 50 pcs. LDP/LD2P raceway cover open during 5 pcs. 50 pcs. installation ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. Optional Mounting Method Rac eway mo un ts easily to s mo oth, cl ean i nterior su rfa ces, h owever, no t a ll su rfaces are su itab le fo r ad hes ive m ou nting . In th ese a pp lication s, u se th e fo am ta pe a s a temp o ra ry m ou nting m ean s. In sert th e raceway in stallation to o l to fa cilita te s crew installatio n. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C10 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Type LDS Surface Raceway PAN-WAY Type LDS Surface Raceway is a single channel, solid one-piece, economical raceway designed to route, protect and conceal data, voice, video or power cabling. Type LDS Raceway Benefits: • Power rated to 600V(UL), 300V(CSA). Meets New! UL5A and CSA 22.2 No. 62-93 standards • NEW! Now FT-4 Rated for Canada • Type LDS is the only non-metallic raceway that is bendable in low A=.21in² LDS3 .41" voltage applications to route around and over obstructions • Extreme tamper resistance • Factory applied adhesive backing speeds installation Par t Number Description Std. Ctn. Qty. Colors u 200 ft. Off White 200 ft. Off White 10 ft. lengths .77" LDS3—Surface Raceway LDS3IW10-A LDS3 A=.38in ² LDS5 Tamper resistant one-piece surface raceway. Supplied with pre-applied adhesive backed tape. LDS5—Surface Raceway .55" 1.01" LDS5 LDS5IW10-A Tamper resistant one-piece surface raceway. Supplied with pre-applied adhesive backed tape. u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. NOT E: LDS Raceway requires screw mounting using the LMD Mounting Straps if it is being used for power cabling applications. NOT E 2: LMD Mounting Straps are recommended in low voltage applications for use near a bend in Type LDS raceway. ORDERING INFORMATION: Order number of feet required, in multiples of Standard Length Increment. See page C14-C15 for fittings Method for Bending Type LDS Raceway (Low Voltage Applications) Step 1: Slide 18 to 30" section of LDS Raceway into PVC pipe heating blanket.* (Recommend blanket designed for bending 1/2" to 1 1/2" PVC conduit.) Step 2: Allow section to heat approximately 2-3 minutes. Raceway will be soft and pliable but should not stretch. (Time will vary with blanket temperature and raceway size.) *Heating blanket not provided by Panduit ® Step 3: Remove raceway section from blanket and hold in desired position until the raceway cools. Install mounting straps immediately. Accessories — Mounting Straps Part Number Used with LDS & LDP Siz e Description Colors u Std. Pkg Qty. Std. Ctn. Qty. Mounted to raceway when running power cables to provide complete tamper resistance and comply with UL listing requirements. Off White 25 pcs. 100 pcs. Off White 25 pcs. 100 pcs. LMD—Mounting Straps • Straps are made of 94V-0 impact resistant ABS/polycarbonate material • Wide enough to be used as coupler between raceway sections LMD3IW-Q Size 3 LMD5IW-Q Size 5 u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C11 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Type LD Surface Raceway PAN-WAY Type LD Surface Raceway is a single channel raceway designed to route, protect and conceal data, voice and video cabling. Type LD Raceway Benefits: • One-piece hinged design allows cables to be laid in • NEW! Now FT-4 Rated for Canada • Factory applied adhesive backing speeds installation Par t Number NEW Sizes! A=.21in² LD3 Par t Number Std. Ctn. Qty. Par t Number Std. Ctn. Qty. Colors u LD3—Surface Raceway .46" .77" LD3 Std. Ctn. Qty. 6 ft. lengths 8 ft. lengths 10 ft. lengths LD3IW6-A 120 ft. LD3IW8-A 160 ft. LD3IW10-A 200 ft. One-piece latching surface raceway. Supplied with pre-applied adhesive backed tape. Off White u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray). WH (White), and BR (Brown). Contact factory for details. A=.38in² LD5—Surface Raceway LD5 .60" 1.01" LD5 Off White u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray). WH (White), BR (Brown), and BL (Black). Contact factory for details. LD10—Surface Raceway A=1.00in ² LD10 LD10 6 ft. lengths 8 ft. lengths 10 ft. lengths LD5IW6-A 120 ft. LD5IW8-A 160 ft. LD5IW10-A 200 ft. One-piece latching surface raceway. Supplied with pre-applied adhesive backed tape. 1.51" .94" 6 ft. lengths 8 ft. lengths 10 ft. lengths LD10IW6-A 120 ft. LD10IW8-A 160 ft. LD10IW10-A 200 ft. One-piece latching surface raceway. Supplied with pre-applied adhesive backed tape. Off White u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray). WH (White), and BR (Brown). Contact factory for details. ORDERING IN FORMAT ION: Order number of feet required, in multiples of Standard Length Increment. See p ag e C14-C15 for fittin gs For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C12 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Type CD Surface Raceway PAN-WAY Type CD Surface Raceway is a single channel, two-piece raceway, designed to route, protect and conceal data, voice and video cabling. Type CD Raceway Benefits: • Unique base design allows wires to be laid in • Factory applied adhesive backing on base speeds installation • NEW! Now FT-4 Rated for Canada CD Surface Raceway Cover—6 ft Lengths Par t Num ber A=.19in² A=.34in ² CD5 Cover of two-piece raceway. Covers snap onto adhesive backed bases. Off White 6 ft. 120ft. CD5IW6 Cover of two-piece raceway. Covers snap onto adhesive backed bases. This size also snaps onto screw mounted metal base below. Off White 6 ft. 120ft. CD10IW6 Cover of two-piece raceway. Covers snap onto adhesive backed bases. This size also snaps onto screw mounted metal base below. Off White 6 ft. 120ft. .60" 1.01" u All parts listed in Off White (IW) color. To order Electrical Ivory substitute EI for IW in above part numbers. Contact factory for details. A=1.00in² CD10 CD10 CD3IW6 .77" CD5 Colorsu Std. Ctn. Qty. CD—Raceway Cover CD3 .46" CD3 Description Std. Length ORDERING INFORMATION: .94" Order number of feet required, in multiples of Standard Length Increment. 1.51" CD Surface Raceway Base—6 ft Lengths, Short Pieces & Metal Base Clips Part Number Used with Raceway Cover Description Std. Std. Ctn. Length Qty. CD—6' Lengths Adhesive Backed Base (for mounting on smooth surfaces) CDB36-A CDB56-A CDB106-A CD3 CD5 CD10 For increased adhesion and impact resistance. Cables are laid into base prior to the cover being snapped on. 6 ft. 120ft. 1.5 in. 2.0 in. 2.0 in. 50 pcs. CD—Short Pieces Adhesive Backed Base CDB CDB3S-A-L CDB5S-A-L CDB10S-A-L CD3 CD5 CD10 For lighter loads. Cables are laid into base prior to the cover being snapped on. Recommended minimum of 4 pieces for each 6 feet of cover. CD—Screw Mounted Metal Base Clips (For mounting on uneven surfaces) CDC5-L CDC10-L CDC CD5 CD10 Cables are laid into base clips prior to the cover being snapped on. Recommended minimum of 4 pieces per each 6 feet of cover. Recommend #6 or #8 screw — 50 pcs. ORDERING IN FORMAT ION: Order number of feet/pieces required in multiples of Standard Length Increment or Standard Carton Quantity. See p ag e C14-C15 for fittin gs For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C13 PAN-WAY ™ PLASTIC SURFACE RACEWAY Standard Fittings for Low Voltage Applications Description Std. Pkg. Qty. Part Number Size 3 CF OCF ICF RAF ECF TF Coupler Fitting Inside Corner Fitting Outside Corner Fitting Right Angle Fitting End Cap Fitting Tee Fitting CF3IW-E ICF3IW-E OCF3IW-E RAF3IW-E ECF3IW-E TF3IW-E Drop Ceiling/ DCF3IW-X Entrance End Reducer RF5X3IW-E Fitting DCF RF Part Number Std. Pkg. Qty. Size 5 20 pcs. 20 pcs. 20 pcs. 20 pcs. 20 pcs. 20 pcs. 10 pcs. 20 pcs. Part Number Std. Pkg. Qty. Colors u Std. Ctn. Qty. Off White Off White Off White Off White Off White Off White Off White Off White 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. Size 10 CF5IW-E 20 pcs. ICF5IW-E 20 pcs. OCF5IW-E 20 pcs. RAF5IW-E 20 pcs. ECF5IW-E 20 pcs. TF5IW-E 20 pcs. DCF5IW-X 10 pcs. RF10X5IW-X 10 pcs. CF10IW-X 10 pcs. ICF10IW-X 10 pcs. OCF10IW-X 10 pcs. RAF10IW-X 10 pcs. ECF10IW-X 10 pcs. TF10IW-X 10 pcs. DCF10IW-X 10 pcs. RF10X3IW-X 10 pcs. u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brown). BL (Black) is also available in Size 5 ONLY. Contact factory for details. ORDERING INFORMATION : Order number of pieces required, in multiples of Standard Package. 1" Bend Radius Fittings for TIA/EIA Compliance Description CFX ICFC ECFX DCEFX TFC RFX Std. Pkg. Qty. Size 3 OCFX RAFC Part Number Coupler Fitting CFX3IW-X Inside Corner Fitting Outside Corner Fitting Right Angle Fitting End Cap Fitting ICFC3IW-X Tee Fitting TFC3IW-X Drop Ceiling/ Entrance End Right Angle Entrance End Reducer Fitting DCEFXIW-X OCFX3IW-X RAFC3IW-X ECFX3IW-X RAEFXIW-X RFX53IW-X Par t Num ber Std. Pkg. Qty. Size 5 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. CFX5IW-X 10 pcs. ICFC5IW-X 10 pcs. OCFX5IW-X 10 pcs. RAFC5IW-X 10 pcs. ECFX5IW-X 10 pcs. TFC5IW-X 10 pcs. DCEFXIW-X 10 pcs. RAEFXIW-X 10 pcs. RFX105IW-X 10 pcs. Par t Number Std. Pkg. Qty. Colors u Std. Ctn. Qty. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. Size 10 CFX10IW-X ICFC10IW-X OCFX10IW-X RAFC10IW-X ECFX10IW-X TFC10IW-X DCEFXIW-X RAEFXIW-X RFX103IW-X Off White Off White Off White Off White Off White Off White Off White Off White Off White u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brown). BL (Black) is also available in select Size 5 Fittings ONLY. Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. RAEFX For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C14 PAN-WAY ™ PLASTIC SURFACE RACEWAY Power Rated Fittings for Power to 600V Description Part Number Coupler Fitting CFX3IW-X Inside Corner Fitting Outside Corner Fitting Right Angle Fitting End Cap Fitting ICFX3IW-X Tee Fitting TFX3IW-X Drop Ceiling/ Entrance End Right Angle Entrance End Reducer Fitting DCEFXIW-X Std. Pkg. Qty. Size 3 CFX ICFX ECFX DCEFX OCFC RAFX TFX RFX OCFC3IW-X RAFX3IW-X ECFX3IW-X RAEFXIW-X RFX53IW-X Par t Num ber Std. Pkg. Qty. Size 5 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. CFX5IW-X 10 pcs. ICFX5IW-X 10 pcs. OCFC5IW-X 10 pcs. RAFX5IW-X 10 pcs. ECFX5IW-X 10 pcs. TFX5IW-X 10 pcs. DCEFXIW-X 10 pcs. RAEFXIW-X 10 pcs. RFX105IW-X 10 pcs. Part Number Std. Pkg. Qty. Colorsu Std. Ctn. Qty. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. Size 10 CFX10IW-X ICFX10IW-X OCFC10IW-X RAFX10IW-X ECFX10IW-X TFX10IW-X DCEFXIW-X RAEFXIW-X RFX103IW-X Off White Off White Off White Off White Off White Off White Off White Off White Off White u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brow n). BL (Black) is also available in select Size 5 Fittings ONLY. Contact factory for details. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. RAEFX Maintains T IA/EIA 568-A and 569-A minimum 1" cable bend radius For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C15 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Type LD2P Multi-Channel Surface Raceway PAN-WAY Type LD2P Surface Raceway is a two channel raceway designed to route, protect and conceal data, voice, video, fiber-optic and power cabling. Type LD2P Raceway Benefits: • Power rated to 600V(UL), 300V(CSA). Meets New! UL5A and CSA 22.2 No. 62-93 standards • NEW! Now FT-4 Rated for Canada • Routes Power & Data together! • Extremely tamper resistant latch for School & University applications NEW! A= .50in 1.51" LD2P10 .86" Std. Ctn. Qty. Part Number Par t Num ber Std. Ctn. Qty. Colorsu 10 ft. lengths LD2P10IW10-A 200ft. Off White LD2P10—Surface Raceway 8 ft. lengths LD2P10IW8-A LD2P10 A= .43in • One-piece hinged design allows cables to be laid in • Factory applied adhesive backing speeds installation 160ft. Two channel tamper resistant one-piece latching surface raceway. Supplied with pre-applied adhesive backed tape. NOTE : LD2P Raceway requires screw mounting if it is being used for power cabling applications u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brown). Contact factory for details. ORDERING INFORMATION: Order number of feet required, in multiples of Standard Length Increment. See page C10 for LDW10-V Installation Tool. Multi-Channel Fittings for Multi-Channel Power & Low Voltage Applications Par t Num ber CFX10IW-X Coupler Fitting ICFX10IW-X Inside Corner Fitting OCFX10IW-X Outside Corner Fitting RAFX10IW-X Right Angle Fitting ECFX10IW-X End Cap Fitting TFXD10IW-X Tee Fitting with Divided Insert EEFXIW Entrance End Fitting Description OCFX CFX ICFX RAFX ECFX TFXD Colors u Std. Pkg. Qty. Std. Ctn. Qty. Off White Off White Off White Off White Off White Off White Off White 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 1 pc. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 100 pcs. 10 pcs. u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brown). Contact factory for details. ORDERING INFORMATION : Order number of pieces required, in multiples of Standard Package. NEW! Maintains TIA/EIA 568-A and 569-A minimum 1" cable bend radius EEFX For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C16 PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for LD Profile Raceways This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. LDS LD 2P LD LDP3 LDP5 LDP10 .21 in² .38 in² .98 in² LD2P10-Lft. LD2P10-Rgt. .43 in² .50 in² LD3 LD5 LD10 .21 in² .38 in² 1.00 in² SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes Fill Capacity Table for: ·Electrical Electrical Cables 14 12 10 THHN/T90 0.105 0.122 0.153 FILL Raceway Type MAX MAX L D2P10-L eft Chann el • • • 9 10 12 14 • • • 6 8 7 11 L D2P10-Rg t. Chann el ** L DS3 9 10 • • • L D3 L D5 L D10 L DP3 L DP5 L DP10* L DS5 CD3 CD5 CD10 LDS3 .21 in² CD CD3 CD5 CD10 .17 in² .33 in² .78 in² LDS5 .38 in² MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP Voice Grade Cables Data Grade Cables 24 AWG UTP CM/CMR 2 pr 3 pr 4 pr DIA.=0.120 DIA.=0.150 DIA.=0.190 FILL FILL FILL 24 AWG/UTP CM 25 pr Cat. 5 4 pr DIA.=0.422 DIA.=0.217 FILL FILL MAX SPEC 7 • MAX SPEC 11 4 MAX SPEC MAX SPEC 7 2 4 — • • 4 5 5 8 13 35 7 13 34 15 20 53 11 20 51 22 8 22 4 8 22 9 12 33 7 12 13 14 5 14 2 5 14 6 8 21 4 8 20 9 ** ** 17 26 11 16 7 10 6 8 • • • 4 5 • • • 7 13 6 11 27 11 20 9 17 41 4 8 3 7 17 7 12 5 11 20 2 5 2 4 11 4 8 3 6 16 MAX SPEC — 2 1 2 — 1 2 1 MAX 3 1 4 — 1 4 1 4 10 2 4 10 4 6 16 3 6 15 6 1 2 5 8 — 1 — — 2 — 1 — 1 3 2 4 1 3 8 3 6 2 5 12 * LDP10 raceway not approved for use with T90 wire; NOTE: See pag e xiv-xv for further explanation of wirefill data. ** Not power configuration; • Not power rated Fill Capacity Table for: ·Data Grade 22 AWG UTP Data Grade Cables 22 AWG UTP CM 24 AWG STP CM Raceway Type L D3 L D5 L D10 L DP3 L DP5 L DP10* L D2P10-Left Chann el L D2P10-Rg t. Channel L DS3 L DS5 CD3 CD5 CD10 25 pr 4 pr DIA.=0.512 DIA.=0.250 SPEC MAX SPEC MAX — — 1 2 — 1 2 4 1 2 8 12 — — 1 2 — 1 2 4 1 2 7 11 — 1 3 5 — 1 4 6 — — 1 2 — 1 2 4 — — 1 2 — — 2 4 1 2 6 ·Data Grade 24, 22 AWG STP 9 ·Type 1A STP Type 1A 22 AWG STP CM STP CM 25 pr 4 pr 25 pr 4 pr DIA.=0.544 DIA.=0.234 DIA.=0.635 DIA.=0.286 DIA.=0.430 SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX — — 1 2 — — 1 1 — — — — 3 5 — — 2 3 1 1 1 2 9 13 1 1 6 9 2 4 — — 1 2 — — 1 1 — — — — 3 5 — — 2 3 1 1 1 2 9 13 1 1 6 9 2 3 — 2 3 5 — — 2 4 1 1 — 1 4 6 — — 3 4 1 2 — — 1 2 — — — 1 — — — — 3 5 — — 2 3 — — — — 1 2 — — 1 1 — — — — 3 4 — — 2 3 — 1 1 2 7 10 — 1 4 7 2 3 NOTE: See page xiv-xv for further explanation of wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C17 FILL CAPACITIES LDP PAN-WAY ™ PLASTIC SURFACE RACEWAY Fill Capacities for LD Profile Raceways FILL CAPACITIES This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. LDS LDP LD 2P LD LDP3 LDP5 LDP10 .21 in² .38 in² .98 in² LD2P10-Lft. LD2P10-Rgt. .43 in² .50 in² LD3 LD5 LD10 .21 in² .38 in² 1.00 in² SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes L D3 L D5 L D10 L DP3 L DP5 L DP10* L D2P10-L eft Chann el L D2P10-Rg t. Chann el L DS3 L DS5 CD3 CD5 CD10 LDS5 .38 in² CD3 CD5 CD10 .17 in² .33 in² .78 in² MAX=60% wir efill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) Fill Capacity Table for: Raceway Type LDS3 .21 in² CD RG6/u RG11/u DIA.=0.270 DIA.=0.405 FILL FILL SPEC MAX SPEC MAX 1 2 — — 2 3 1 1 6 10 3 4 1 2 — — 3 4 1 1 6 10 3 4 3 4 1 1 3 5 1 2 1 2 — — 2 3 1 1 1 1 — — 2 3 1 1 5 8 2 3 ·Coax Cables Coax Cables RG58/u RG59/u RG62A/u DIA.=0.193 DIA.=0.242 DIA.=0.242 FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX 2 4 1 2 2 3 5 7 3 4 3 5 13 20 8 13 9 13 2 4 1 2 2 3 5 7 3 4 3 5 13 20 8 12 9 13 5 8 3 5 4 6 6 10 4 6 4 7 2 4 1 2 2 3 5 7 3 4 3 5 2 3 1 2 2 3 4 6 2 4 4 5 10 15 6 10 9 13 NOTE: See pag e xiv-xv for further explanation of wirefill data. Fill Capacity Table for: Raceway Type LD3 LD5 LD10 LDP3 LDP5 LDP10 LD2P10-Left Channel LD2P10-Rgt. Ch an nel LDS3 LDS5 CD3 CD5 CD10 ·Fiber Optic Cable (62.5/125mm) Fiber Optic Cables (62.5/125mm) 2 Strand 4 Strand 6 Strand 18AWG DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX 3 5 4 5 2 3 24 36 6 9 6 9 4 6 44 66 16 24 16 24 11 17 6 175 3 5 3 5 2 3 25 37 6 9 6 9 4 6 44 67 16 24 16 16 11 16 114 171 7 10 7 11 4 7 50 75 8 12 8 12 5 8 58 87 3 5 3 5 2 3 24 36 6 9 6 9 4 6 44 66 2 4 4 6 1 2 19 29 5 8 7 10 3 5 38 57 12 19 17 25 9 13 91 136 ·Signal Cables Signal Cables 20 AWG 22 AWG 24 AWG DIA.=0.057 DIA.=0.050 DIA.=0.044 FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX 32 49 42 64 55 82 59 89 77 116 99 149 156 235 203 305 263 394 32 49 42 64 55 82 59 89 77 116 99 149 153 270 199 299 257 386 67 101 87 131 113 169 78 117 101 152 131 197 32 49 42 64 55 82 59 89 77 116 99 149 26 39 34 51 44 67 51 77 67 100 86 130 122 183 158 238 205 307 NOTE: See page xiv-xv for further explanation of wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) C18 D PAN-WAY ™ SURFACE RACEWAY B PAN-WAY ™ Type PD Surface Raceways Type PD for Power or Communications Cabling PAN-WAY Type PD Surface Raceway provides a complete system for routing and protecting either power or communication cabling. Type PD Raceway is a two piece, low profile, single channel raceway system. Type PD Raceway offers exceptional tamper resistance. Panduit PAN-WAY Type PD Raceway provides the following key benefits: • • • • • • • UL-5A Listed to 600 V and CSA 22.2 No. 62-93 Listed to 300 V Superior tamper resistance, ideal for school and university applications Extremely impact resistant 2 sizes to meet your application requirements Four standard colors available to blend with surrounding decor Selection of fittings to speed installation Available in 6', 8' and 10' lengths For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D1 PAN-WAY ™ SURFACE RACEWAY Table of Contents Page PAN-WAY ™ Type PD Surface Raceway . . . . . . . . . . . . . . . . . . . . . . . . . . . D7 1 2 3 4 Configurations . . . . . . . . . . . . . . . . D4-D5 PAN-WAY Type PD Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D8 Fill Capacity Information . . . . . . . . . . D9-D10 Additional Related Products PAN-WAY Faceplates . . . . . . . . . . . . . . . . . . . . . . . . A3 PAN-WAY Surface Mount Outlet Boxes . . . . . . . E3-E5 PAN-WAY Accessories . . . . . . . . . . . . . . . . . . . . . . . H1 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D2 PAN-WAY ™ SURFACE RACEWAY PAN-WAY ™ Type PD Raceways—Roadmap Power ONLY Applications PAN-WAY ™ Electrical Outlets page A4 PD Fittings page D8 PAN-WAY ™ Electrical Faceplates page A3 PD6 Base & Cover page D7 PD3 Base & Cover page D7 PAN-WAY Power Rated Surface Mount Outlet Boxes page E4 CONFIGURATIONS 2 1 Data ONLY Applications 3 4 See page D4-E5 PAN-WAY Screw-On Electrical/Communication Faceplates page A3 PD6 Base & Cover page D7 Standard Communications Faceplate Standard Communications Module Frame PD Fittings page D8 PAN-WAY Single Gang FAST-SNAP ™ Surface Mount Outlet Box page E3 PAN-WAY Snap-On Communication Faceplates PD3 Base & Cover page D7 (with screw holes to mount a module frame) page A3 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D3 PAN-WAY ™ SURFACE RACEWAY PAN-WAY ™ PD Raceway Configurations Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V) in horizontal applications. 1 PAN-WAY Snap-On Electrical/Communications Faceplates PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) 2 4 5 2 2 3 3 Data Only (B) Data Only (A) • Snap-On Faceplates provide a superior appearance • Can use most manufacturers’ communication module frames (see chart on page vii) • FAST-SNAP ™ Boxes snap together for quick installation • Data and Power box is divided to maintain separation Components Required Data (A) Data (B) PD RACEWAY CONFIGURATIONS Configurations for this faceplate style not currently available. See Page 1 2 3 4 1. PD3 or PD6 Raceway X X 2. Snap-On Electrical/Communication Faceplate(s) (with screw holes to mount a module frame) X X 3. 4. Standard Communication Module Frame(s) Single Gang FAST-SNAP Outlet Box 5. D ouble Gang FAST-S NAP Outlet Box X X X X 6. R aceway Adapter (BA3 or BA6) to adapt PD to LD10 box X X breakout D7 A3 vii E3 E3 E5 No te: Fo r d ata area(s) an d fill capacity info rmation see page D9-D10 Data Only (A) 1 2 3 5 Data Only (B) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D4 PAN-WAY ™ SURFACE RACEWAY PAN-WAY ™ PD Raceway Configurations Cont’d PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 3 3 2 5 2 6 4 2 3 5 X X D7 X A3 X vii A4 E3 X E4 X E5 1. PD3 or PD6 Raceway 2. U.S. Standard Screw-On Electrical/Communication Faceplate(s) (single or double gang available) X 3. Standard Communication Module Frame(s) X 4. 5. PAN-WAY Electrical Outlet(s) (ERU20 shown) Low Voltage Surface Mount Outlet Boxes (7 styles to choose from) 6. Power Rated Surface Mount Outlet Boxes (5 styles to choose from) 7. Raceway Adapter (BA3 or BA6) to adapt PD to LD10 box breakout 3 Data Only Power Only Components Required 1 Data Only Power Only Data Only See Page X X Note: F or data area(s) and fill capacity info rm ation see page D9-D10 1 NEW! Optional for Power 2 • 20A Low Profile Surface Mount Outlet Box includes box, 20A outlet and cover in duplex rectangular or 106 styles 4 6 Power Only 4 Components Required Power Only 4 See Page 1. PD3 or PD6 Raceway X D7 2. 20A Low Profile Rectangular or 106 Style Surface Mount Outlet Boxes (include box, 20A outlet & self cover) X A4 3. Raceway Adapter (BA3 or BA6) to adapt PD to LD10 box breakout X E5 U.S. Standard Screw-On Communication Faceplates 2 2 3 3 1 4 Data Only 5 • Uses selected manufacturers’ standard communication faceplates • Panduit ® Styles available, for more information refer to page xii See Page 1. PD3 or PD6 Raceway X D7 2. Most Mfg. U.S. Screw-On Standard Communication Faceplates (see page listed for Panduit styles) X — 3. Manufacturers’ inserts and/or modules X — 4. Low Voltage Surface Mount Outlet Box (7 styles to choose from) X E3 5. Raceway Adapter (BA3 or BA6) to adapt PD to LD10 box breakout X E5 Components Requir ed 4 Note: For data area(s) and fill capacity in formation see pag e D9 -D10 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D5 PD RACEWAY CONFIGURATIONS • U.S. Standard Screw-On Electrical Faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) PAN-WAY ™ SURFACE RACEWAY PAN-WAY ™ Surface Raceway Applications PAN-WAY Type PD Surface Raceway is ideal for power or low voltage cabling applications. It can be used anywhere power or low voltage cabling is r equired including offices, factories, schools, universities, etc. NEMA Standard Faceplates can be mounted to surface mount outlet boxes for use with Type PD Raceway in network cabling applications. The “Flexible” fitting can be used to route Type PD Raceway installation around or over obstacles. (See page D8) Type PD Raceway can be connected directly to conduit with the “Entrance End” fitting. (See page D8) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D6 PAN-WAY ™ SURFACE RACEWAY PAN-WAY ™ Type PD Surface Raceway PAN-WAY Type PD Surface Raceway is a single channel raceway system to route, protect and conceal power, data, voice, or video cabling. PD System Benefits: • UL-5A Listed to 600 V and CSA 22.2 No. 62-93 Listed to 300 V • NEW! Now FT-4 Rated for Canada Type PD Raceway Bases and Covers A=0.14in² A 0.37" (9 .4 mm) 0.86" • Extremely tamper resistant for School & University applications 6 ft. Part Number Std. Ctn. Qty. 10 ft. Part Number 160 ft. PD3IW10 8 ft. Par t Number Std. Ctn. Qty. Coloru B Type PD3 Raceway Base and Cover 6 ft. lengths PD3IW6 (2 1.8mm) Std. Ctn. Qty. 8 ft. lengths 120 ft. PD3IW8 10 ft. lengths 200 ft. Off White Raceway Base and Cover packaged together. Raceway Base without adhesive backing. Cover Dimensions: .86(21.8mm)x.37(9.4mm) Type PD3 Raceway Base and Cover - Adhesive Backed 6 ft. lengths PD3 PD3IW6-A 8 ft. lengths 120 ft. PD3IW8-A 160 ft. 10 ft. lengths PD3IW10-A 200 ft. Off White Raceway Base and Cover packaged together. Raceway Base with pre-applied adhesive backing to speed installation. Type PD6 Raceway Base and Cover 6 ft. lengths PD6IW6 A=0.33in² A 1.33" 0.46" (1 1.7mm) 8 ft. lengths 120 ft. PD6IW8 160 ft. 10 ft. lengths PD6IW10 200 ft. Off White Raceway Base and Cover packaged together. Raceway Base without adhesive backing. Cover Dimensions: 1.33(33.8mm)x.46(11.6mm) Type PD6 Raceway Base and Cover - Adhesive Backed (3 3.8mm) 6 ft. lengths PD6IW6-A 8 ft. lengths 120 ft. PD6IW8-A 160 ft. 10 ft. lengths PD6IW10-A 200 ft. Off White Raceway Base and Cover packaged together. Raceway Base with pre-applied adhesive backing to speed installation. PD6 u All parts listed in Off White (IW) color. To order Electrical Ivory substitute EI for IW in above part numbers. Contact factory for details. ORDERING INF ORMATION: Order number of feet required, in multiples of Standard Length Increment. NOTE: Type PD Raceway Base req uires screw mou nting if it is being u sed for power cabling ap plications. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D7 PAN-WAY ™ SURFACE RACEWAY PAN-WAY Type PD Raceway Fittings Par t Number Coupler Fitting Right Angle Fitting Inside Corner Fitting Entrance End Fitting Breakout for 1/2" conduit Outside Corner Fitting Flexible Fittings Tee Fitting Flexible Fittings Description Coloru Std. Pkg. Qty. Std. Ctn. Qty. PCF3IW-X Type PD3 – Coupler Fitting Off White 10 pcs. 100 pcs. PCF6IW-X Type PD6 – Coupler Fitting Off White 10 pcs. 100 pcs. PICF3IW-X Type PD3 – Inside Corner Fitting Off White 10 pcs.. 100 pcs. PICF6IW-X Type PD6 – Inside Corner Fitting Off White 10 pcs. 100 pcs. PRAF3IW-X Type PD3 – Right Angle Fitting Off White 10 pcs. 100 pcs. PRAF6IW-X Type PD6 – Right Angle Fitting Off White 10 pcs. 100 pcs. PEEF36IW-X Type PD3 and PD6 – Entrance End Fitting Off White 10 pcs. 100 pcs. POCF3IW-X Type PD3 – Outside Corner Fitting Off White 10 pcs. 100 pcs. POCF6IW-X Type PD6 – Outside Corner Fitting Off White 10 pcs. 100 pcs. PTF3IW-X Type PD3 – Tee Fitting Off White 10 pcs. 100 pcs. PTF6IW-X Type PD6 – Tee Fitting Off White 10 pcs. 100 pcs. PFF36EI18 Type PD3 and PD6 – Flexible Fitting for “Raceway to Raceway” Elec. Ivory 1 pc. 10 pcs. PFBC36EI18 Type PD3 and PD6 – Flexible Fitting for “Raceway to Conduit Junction Box” Elec. Ivory 1 pc. 10 pcs. PECF3IW-X Type PD3 – End Cap Fitting Off White 10 pcs. 100 pcs PECF6IW-X Type PD6 – End Cap Fitting Off White 10 pcs. 100 pcs. PWR6-X PD6 Wire Retainer Natural 10 pcs. 100 pcs. u All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. End Cap Fitting Wire Retainer F or use with PD6 Raceway For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D8 PAN-WAY ™ SURFACE RACEWAY Fill Capacities for Type PD Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. SPEC=40% wir efill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temperature rise test for electrical 0.37" ·Electrical 0.46" 0.86" 1.33" PD3 PD6 Fill Capacity Table for: ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP Electrical Cables Voice Gr ade Cables Data Grade Cables AWG 24 AWG UTP CM/CMR 24 AWG UTP CM 14 12 10 2 pr 3 pr 4 pr 25 pr Cat. 5 4 pr THHN/T90 DIA.= 0.120 DIA.= 0.150 DIA.= 0.190 DIA.=0.422 DIA.=0.217 0.105 0.122 0.153 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Configurations B PD3 5 4 — 5 7 3 5 2 3 — — 2 2 PD6 10 7 5 12 18 7 11 5 7 — — 4 5 PD6 with retain er 10 7 5 7 11 5 7 3 4 — — 2 3 NOTE: See page xiv-xv for further explanation of the wirefill data. Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP Data Grade Cables 22 AWG UTP CM 22 AWG STP CM 25 pr 4 pr 25 pr 4 pr 24 AWG STP CM 25 pr 4 pr Raceway Channel Configurations ·Type 1A STP 1A 22 AWG STP CM DIA.=0.512 DIA.=0.250 DIA.= 0.544 DIA.= 0.234 DIA.=0.635 DIA.=0.286 DIA.=0.430 FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX PD3 — — 1 2 — — 1 2 — — — — — — PD6 — — 3 4 — — 3 5 — — 2 3 — — PD6 with retainer — — — — — — — — — — — — — — NOT E: See p age xiv-xv for further explanation of the wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D9 TYPE PD FILL CAPACITIES A=0.33in² A=0.14in ² PAN-WAY ™ SURFACE RACEWAY Fill Capacities for Type PD Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. TYPE PD FILL CAPACITIES SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temperature rise test for electrical Fill Capacity Table for: ·Coax Cables Coax Cables RG6/u RG11/u RG58/u RG59/u RG62A/u DIA.=0.270 DIA.=0.405 DIA.=0.193 DIA.=0.242 DIA.=0.242 FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Configurations PD3 — — — — 2 3 1 2 1 2 PD6 2 3 — — 5 7 3 4 3 4 PD6 with retainer — — — — 3 4 — — — — NOTE: See page xiv- xv for further explanation of the wirefill data. Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Fiber Optic Cables (62.5/125mm) Signal Cables 2 Strand 4 Strand 6 Strand 18AWG 20 AWG 22 AWG 24 AWG DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 DIA.=0.057 DIA.=0.050 DIA.=0.044 FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Configurations PD3 2 3 2 3 2 2 16 25 22 33 29 43 37 55 PD6 5 8 5 8 4 6 39 58 52 78 67 101 87 130 PD6 with retainer 3 5 3 5 2 4 25 37 33 49 43 64 55 83 NOT E: See p age xiv-xv for further explanation of the wirefill data. B R aceway Cutting Instructions: ·For Type PD Raceway, use Panduit Cutting Tool, Part No. SRT found on page H1. Alternative method: For small quantities, use a fine tooth handsaw. For larger quantities, a fine tooth saw (10" dia., high speed steel, 1/16" thick, hollow ground to 2" collar diameter, 300 tooth, alternate top bevel, 14", no set blade) will produce good results. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) D10 E PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Surface Mount Outlet Boxes PAN-WAY Surface Mount Outlet Boxes are available to mount, conceal and terminate power and communication cables with PAN-WAY Plastic Surface Raceway. All are available in colors to match or complement the raceway. Surface Mount Outlet Boxes • One-gang and two-gang styles for fiber optic, low voltage and power applications • New FAST-SNAP ™ boxes and faceplates provide screwless installations • Provide access to length of cable to facilitate termination • Compatible with LD Profile or PD Raceways • Power rated boxes UL 5A Listed to 600V and CSA Certified to 300V • Select styles available in 6 colors • FAST-SNAP boxes available in 4 colors For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) E1 PAN-WAY ™ PLASTIC SURFACE RACEWAY Table of Contents Page PAN-WAY ™ FAST-SNAP ™ Surface Mount Outlet Boxes NEW! For Power and Communications Cabling . . . . . . . . . . E3 Accepts Snap-On Faceplates PAN-WAY Low Voltage Surface Mount Outlet Boxes For Communications Cabling . . . . . . . . . . . . . . . . . . . E3 PAN-WAY Power Rated Surface Mount Outlet Boxes For Power or Communications Cabling. . . . . . . . . . . . E4 PAN-WAY Divided Surface Mount Outlet Boxes For Power & Communications Cabling . . . . . . . . . . . . E5 Raceway Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . E5 Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E6 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) E2 PAN-WAY Œ PLASTIC SURFACE RACEWAY PAN-WAY Œ FAST-SNAP Œ6XUIDFH0RXQW2 XWOHW%R[HV 1(: &RPPXQLFDWLRQ2QO\ 3DUW 1XPEHU 'HVFULSWLRQ &RORU◆ $FFHSW  6LQJOH*DQJFAST-SNAP/RZ9ROWDJH6XUIDFH0 RXQW2XWOHW%R[ Snap-On 6LQJOHJDQJVQDSWRJHWKHUFRYHU DQGEDVH ZLWK 2II :KLWH )DFHSODWHV -%)6,:$ DGKHVLYHEDFNLQJ$FFHSWV PAN-WAY6QDS2 Q )DFHSODWHVIRU GDWDDSSOLFDWLRQV /  : +  &RQGXLW EUHDNRXW V ô ò )RUXVHZLWKVLQJOH FKDQQHOUDFHZD\V -%)6 $ 1(: 3RZHU &RPPXQLFDWLRQ 6WG 3NJ 4W\ 6WG &WQ 4W\ SF  SFV 'RXEOH*DQJFAST-SNAP3RZHU5DWHG6XUIDFH0RXQW2XWOHW%R[ -%3 )6,: $FFHSW Snap-On )DFHSODWHV 'RXEOHJDQJVQDSW RJHWKHUFRYHU DQGEDVH 2II :KLWH $FFHSWVPAN-WAY6QDS2Q)DFHSODWHVI RUSRZHU DQGGDWDDSSOLFDW LRQV /  : +  &RQGXLW EUHDNRXW V ô ò )RUXVHZLWKPXOW LFKDQQHOUDFHZD\V SF  SFV ◆ $OOSDUWVOLVWHGLQ2 II:KLWH ,: FRORU7RRU GHU RWKHU FRORU VVXEVWLWXWH(, (OHFWU LF,YRU\ ,* /LJKW*UD\ DQG :+ :KLWH &RQWDFWIDFWRU\IRU GHWDLOV 25'(5,1*,1)2 50 $7 ,21 2UGHUQXPEHURISLHFHVUHTXLUHGLQPXOWLSOHVRI6WDQGDU G3DFNDJH -%3 )6 PAN-WAY /RZ9ROWDJH6XUIDFH0RXQW2 XWOHW%R[HV 1( : 1HZ ,PSURYHG ' HVLJQ 3DUW 1XPEHU 'HVFULSWLRQ &RORU◆ 6WG 3NJ 4W\ 6WG  &WQ 4W\ 6LQJOH*DQJ7ZR3LHFH6QDS7RJHWKHU%R[ -%; ,:$ 7ZR3LHFHER[ZLWK DGKHVLYHEDFNLQJ / : +  &RQGXLWEUHDNRXWV  ô ò 2II:KLWH SF SFV 2II:KLWH SF SFV 2II:KLWH SF SFV 'RXEOH*DQJ%R[EDVH FRYHU VFUHZVLQFOXGHG  2II:KLWH / : +  &RQGXLWEUHDNRXWV ô ò SF SFV 6LQJOH*DQJ2QH3LHFH%R[ -%;  $ -%,:$ 2QH3 LHFH %R[ ZLWKDGKHVLYHEDFNLQJ / : +  &RQGXLWEUHDNRXWV  ô ò 6LQJOH*DQJ2QH3LHFH'HHS%R[ -%',:$ -% $ -%' $ 'RXEOH*DQJ7ZR3LHFH%R[ -%3 ,: 1( : 2QH3LHFH'HHS% R[ZLWKDGKHVLYHEDFNLQJ / : +  &RQGXLWEUHDNRXWV  ô ò 1( : 'RXEOH*DQJ7ZR3LHFH'HHS%R[ -%3 ', : 'RXEOH*DQJ'HHS% R[EDVHFRYHUDQGGLYLGHU ZDOO VFUHZVLQFOXGHG  / : +  &RQGXLWEUHDNRXWV  ô ò 2II:KLWH SF SFV 2II:KLWH SF SFV 5RXQG7ZR3LHFH%R[ -%3 -%3' 5-%;  ,: 5RXQG% R[EDVH FRYHU VFUHZVQRWLQFOXGHG  ', $+  &RQGXLWEUHDNRXWV  ô 5RXQG%R[$GDSWHU -%$; $GDSWVVLQJOHJDQJVXUIDFHPRXQWRXWOHWER[HVW RLQZDOOFRQGXLW SF SFV ER[HV ◆$OOSDUWVOLVWHGLQ2II:KLWH ,: FRORU7RRUGHURWKHUFRORUVVXEVWLWXWH(, (OHFWULF,YRU\ ,* /LJKW* UD\  5-%;  -%$; :+ :KLWH %5 %URZQ DQG%/ %ODFN &RQWDFWIDFWRU \IRUGHWDLOVIRUDYDLODELOLW\RIVSHFLILFVW\OHVDQGFRORUV 2 5'(5,1 *,1)2 50$7,2 1 2 UGHUQXPEHU RISLHFHVUHTXLU HGLQPXOWLSOHVRI6WDQGDUG3DFNDJH 12 7(6HH6HOHFWLRQ&KDU WRQSDJH(IRU GHWDLOHGLQIRU PDWLRQRQVSHFLILFXVDJHZLWKUDFHZD\V )RU7HFKQLFDO$VVLVWDQFHFDOO   ([W RXWVLGHWKH86VHHLQVLGHEDFNFRYHU IRU ,QWHU QDWLRQDO'LUHFWRU\ ( PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Power Rated Surface Mount Outlet Boxes NEW! Low Profile Box Part Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Power Rated Single Gang Two-Piece Low Profile Box J JBP1E JBP1EIW Single Gang Low Profile Box—base and cover. L= 4.99" W=3.30" H=1.00" Conduit breakouts: ½", ¾", 1" Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Power Rated Single Gang Two-Piece Box J JBP1IW JBP1 JBP1I JPower Rated Single Gang Two-Piece Intermediate Box JBP1IIW NEW! Single Gang Box—base and cover. L= 5.19 W=3.45" H=1.75" Conduit breakouts: ½", ¾", 1" Single Gang Intermediate Box—base and cover. L= 5.12" W=3.38" H=2.27" Conduit breakouts: ½", ¾" Power Rated Single Gang Two-Piece Deep Box J JBP1DIW Single Gang Deep Box—base and cover. L= 5.19" W=3.26" H=2.75" Conduit breakouts: ½", ¾", 1" Power Rated Double Gang Two-Piece Box J JBP1D JBP2 JBP2IW Power Rated Double Gang Two-Piece Deep Box J NEW! JBP2DIW JBP2D Double Gang Box—base & cover (screws included). L= 5.05" W=5.05" H=1.62" Conduit breakouts: ½", ¾" PSJBX Double Gang Deep Box—base, cover and divider wall (screws included). L= 5.19" W=5.19" H=2.75" Conduit breakouts: ½", ¾", 1" Power Rated Two-Piece Power Source Box J PSJBXIW Power Source Box—base & cover (screws not included). L= 5.02" W=3.27" H=1.31" Conduit breakouts: ½", ¾", 1" Power Rated Two-Piece Round Box J PRJBX36IW PRJBX36 Round Outlet Box—base & cover (screws not included). Dia: 5.25" H=1.05" Conduit breakouts: ¾", 1" ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), BR (Brown) and BL (Black). Contact factory for details for availability of specific styles and colors. ORDERING INFORMATION : Order number of pieces required, in multiples of Standard Package. NOT E: See Selection Chart on p ag e E6 for detailed information on specific usage with raceways. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) E4 PAN-WAY ™ PLASTIC SURFACE RACEWAY PAN-WAY ™ Divided Surface Mount Outlet Boxes NEW! Part Number Description Std. Pkg. Qty. Color◆ Std. Ctn. Qty. Power Rated Single Gang Two-Piece Deep Box JBP1DIW JBP1D JBD1 Single Gang Deep Box—base and cover. L=5.19" W=3.26" H=2.75" Conduit breakouts: ½", ¾", 1" Off White 1 pc. 10 pcs. — 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Single Gang Pass Through Divider for LD2P10 Raceway J JBD1 NEW! Pass through divider allows power & communications outlets to be routed in series. Used with JBP1D box. Must use with LD2P10 Raceway. NEW! Power Rated Double Gang Three-Piece Divided Box JBP2SIW JBP2S JBP2D Double Gang Box—base, cover and divider wall for power and data applications (screws included). L=5.05" W=5.05" H=1.62" Conduit breakouts: ½", ¾" Power Rated Double Gang Two-Piece Deep Box J JBP2DIW NEW! Double Gang Deep Box— base, cover and divider wall (screws included) L=5.19" W=5.19" H=2.75” Conduit breakouts: ½", ¾", 1" Double Gang Pass Through and Divider for LD2P10 Raceway J JBD2 Pass through divider allows power & communications outlets to be routed in series. Used with JBP2D box. Must use with LD2P10 Raceway. — 1 pc. 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), JBD2 WH (White), BR (Brown) and BL (Black). Contact factory for details for availability of specific styles and colors. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. NOTE: See Selection Chart on page E6 for detailed information on specific usage with raceways. Raceway Adapters Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. 10 pcs. 100 pcs. 10 pcs. 100 pcs. Off White 10 pcs. 100 pcs. Off White 10 pcs. 100 pcs. Color◆ Raceway Adapters for LD Profile Raceways J CA3IW-X CA5IW-X Fits into universal breakout of DCEFX or RAEFX fittings. For Off White use with Types LDP3, LD3, and LDS3 raceways. Fits into universal breakout of DCEFX or RAEFX fittings. For Off White use with Types LDP5, LD5, and LDS5 raceways. Raceway Adapters for PD Raceways J BA3IW-X BA6IW-X Fits into LD10 breakout of most PAN-WAY Surface Mount Outlet Boxes. For use with Type PD3 raceway. Fits into LD10 breakout of most PAN-WAY Surface Mount Outlet Boxes. For use with Type PD3 raceway. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), WH (White), and BR (Brown). BL (Black) is also available in select Size 5 Fittings ONLY. Contact factory for details. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package. NOTE: See Selection Chart on page E6 for detailed information on specific usage with raceways. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) E5 PAN-WAY ™ PLASTIC SURFACE RACEWAY Selection Chart for using PAN-WAY ™ Plastic Surface Raceways with PAN-WAY Surface Mount Outlet Boxes SELECTION CHART How to use this chart: 1) Locate the desired PAN-WAY Raceway in the left column. 2) Locate the desired box in the top row. 3) Locate the intersecting space to see if they can be used together. 4) Color indicates proper box breakout (or adapter for PD raceway.) B PAN-WAY Outlet Boxes Low Voltage ONLY PAN-WAY Fittings Power or Low Voltage JB1 , JB1 D, JB1 FS, J BX3 5 10 R JBX 351 0 J BP1 JB P1 D JBP1 E JBP 1I, JBP2 JBP 2S, JB P2 D, J BP2 FS PR JBX 36 PS JBX T3 TRA NS , R AE FX, D C EFX Type LD (Low Voltage ONLY) LD 3 Y Y Y Y N Y Y N Y Y w /CA 3 LD 5 Y Y Y Y N Y Y N Y Y w / C A5 LD 10 Y Y Y Y N Y Y N Y Y Type LDP (Power or Low Voltage) LD P3 Y Y Y Y Y Y Y N Y Y w /CA 3 LD P5 Y Y Y Y Y Y Y N Y Y w / C A5 LD P1 0 Y Y Y Y Y Y Y N Y Y Type LDS (Power or Low Voltage) LD S3 Y Y Y Y Y Y Y N Y Y w /CA 3 LD S5 Y Y Y Y Y Y Y N Y Y w / C A5 N N Y w /JBD 1 N N Y N N N Type LD2P10 (Power and Low Voltage) LD 2P 10 N Type CD (Low Voltage ONLY) C D3 Y Y Y Y N Y Y N Y Y w /CA 3 C D5 Y Y Y Y N Y Y N Y Y w / C A5 C D1 0 Y Y Y Y N Y Y N Y Y Type PD (Power or Low Voltage) PD 3 Y w /B A3 N Y w /B A3 Y w /B A3 Y w /BA3 Y w/BA 3 Y w/BA 3 Y N N PD 6 Y w /B A6 N Y w /B A6 Y w /B A6 Y w /BA6 Y w/BA 6 Y w/BA 6 Y N N Y Y Y N Y N Type T3 Transition Fitting (Power or Low Voltage) T3 Tra nsition Fitting Y N Y Y Breakout Schemes Adapters LD10, LD P10, L D2P10, CD10; T3; PD & Ad ap ter PD Adapters LD5, LDP5, LDS5, CD5 LD3, LDP3, LDS3, CD3 BA3 BA6 BA3 & BA6 adapters found on page E5. Adapters fit LD10 Breakout. PD3 PD6 LD L D10, L DP10, LD2P10, C D10 Un iversal Breakout Adapters CA3 CA5 CA3 & CA6 adapters found on page E5. Adapters fit Universal Breakout. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) E6 F PAN-WAY ™ SURFACE RACEWAY SYSTEM NEW! PAN-WAY ™ TE-70 Non-Metallic Surface Raceway for Power and Communications Cabling PAN-WAY TE-70 Surface Raceway provides a complete system for routing, protecting and terminating both your communications and power cabling systems. The multi-channel design keeps electrical and communication cables separated. This gives you the flexibility to install power cables first, then easily add communication cables later. Type TE-70 Raceway is tamper-resistant while also allowing you access for moves, adds and changes. Panduit PAN-WAY TE-70 Raceway provides the following key benefits: • Large Capacity for power and communication applications • Power Rated to 600V (UL) meets new UL5A standards, 300V (CSA) meets CSA 22.2 No. 62-93 standards • Covers and fittings are extremely tamper resistant • New! Snap-On Electrical/Communication Faceplates require less hardware for quick terminations and lower installed cost • Four standard colors available to complement any surrounding decor For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F1 PAN-WAY ™ SURFACE RACEWAY SYSTEM Table of Contents PAN-WAY ™ TE-70 Page 1 2 3 4 Configurations . . . . . . . . . . . . . . . . . . .F4-F5 Raceway Base & Cover. . . . . . . . . . . . . . . . . . . . . . . . F6 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . F8-F10 PAN-WAY TE-70 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F6 PAN-WAY TE-70 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F7 PAN-WAY Snap-On Faceplates Electrical/Communication Faceplates . . . . . . . . . . . . . A3 Electrical/Communication Faceplates (with screw holes to mount a module frame) . . . . . . . . A3 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F2 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ TE-70 Non-Metallic Raceway—Roadmap TE-70 System T-70 CONFIGURATIONS 1 TE-70 Base page F6 TE-70 Cover page F6 2 3 4 See page F4 - F5 PAN-WAY Snap-On Electrical/Communication Faceplate page A3 PAN-WAY Electrical Outlet page A4 PAN-WAY Snap-On Communication Faceplate (with screw holes to mount a module frame) page A3 Standard Communication Module Frame PAN-WAY Snap-On PAN-WAY Electrical/Communication Electrical Outlet Faceplates page A3 page A4 PAN-WAY Snap-On Electrical/Communication Faceplate page A3 Standard Communication Module Frame PAN-WAY Snap-On Communication Faceplate (with screw holes to mount a module frame) page A3 PAN-WAY Snap-On Electrical/Communication Faceplate page A3 PAN-WAY Electrical Outlet page A4 TE70 Fittings page F6 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F3 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ TE-70 Raceway Configurations 1 Base: page F6 Cover: page F6 Fittings: page F6 TE-70 PAN-WAY Snap-On Electrical/Communications Faceplates 2 3 4 1 3 2 4 4 1 1 5 6 Data & Power Power Only 1 Data Only 3 Areas (in²) Data & Power Data Only Power Only 2 A 1.65 — 7.20 B 3.66 6.80 — 1. Snap-On Electrical/Comm. Faceplate(s) (T70PG shown) 2. Standard Communication Module Frame 3. 4. 5. PAN-WAY Electrical Outlet (ERU20) Device Mounting Bracket (T 70DB-X shown) Hanging Box (TE70HB shown) 6. Divider Wall (T E70DW shown) X X X Data & Power Components Required Power Only 2 Data Only • Snap-On Faceplates provide a superior appearance • Can use most manufacturers’ communication module frames (see chart on page vii) See Page X X X X X X X A3 vii A4 F7 F7 F6 X X PAN-WAY Snap-On Communication Faceplates (with screw holes for module frames) 2 1 1 • Faceplate requires no mounting bracket or hanging box • Can use most manufacturers’ communication module frames (see chart on page vii) 2 Data Only Areas (in²) Data Only A — B 7.33 Data On ly TE-70 CONFIGURATIONS Application: Routing low voltage cables and/or power cabling: Fiber Optic, Categor y 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V) in horizontal applications. See Page 1. Snap-On Communication Faceplate (with screw holes for mounting module frame) (T70PGS shown) X A3 2. Standard Communications Module Frame X vii Components Required Note: For power and data applications use with configuration #1 above or with configuration #3 shown on next page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F4 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ TE-70 Raceway Configurations Cont’d Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V) in horizontal applications. TE-70 CONFIGURATIONS 3 TE-70 Base: page F6 Cover: page F6 Fittings: page F6 PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 4 2 1 3 3 2 1 4 4 1 5 6 Data & Power 1 Power Only Data Only 3 • U.S. Standard screw-on electrical faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) Areas (in²) Data & Power Data Only Power Only 4 A 1.65 — 7.20 B 3.66 6.80 — U.S. Standard Screw-On Electrical/Comm. Faceplate(s) (CPG shown) X 2. Standard Communication Module Frame X 3. 4. 5. PAN-WAY Electrical Outlet (ERU20) Device Mounting Bracket (T70DB-X shown) Hanging Box (T E70HB shown) 6. Divider Wall (TE70DW shown) X Data & Power 1. Components Required Power On ly Data On ly 2 See Page X X A3-A4 X X X X X vii A4 F7 F7 F6 X X U.S. Standard Screw-On Communication Faceplates 3 2 1 1 • Uses most manufacturers’ communication faceplates • Panduit ® Styles available, for more information refer to page xii 3 Areas (in²) Data Only A — B 7.18 Components Required 1. Most Mfg. U.S. Screw-On Standard Comm. Faceplate 2. Device Mounting Bracket (T 70DB-X shown) 3. Manufacturers’ inserts and/or modules Data Only Data Only See Page X X X — F7 — Note: For power and data applications use w ith configuration #3 above or with configuration #1 shown on previous page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F5 PAN-WAY ™ SURFACE RACEWAY SYSTEM Type TE-70 Surface Raceway Base & Cover PAN-WAY Type TE-70 Surface Raceway is a large capacity, multi-channel system used to route, protect, and conceal data, voice, video and power cabling systems. Type TE-70 System Benefits: • Power rated to 600V(UL), 300V(CSA) meets new UL5A standard and CSA 22.2 No. 62-93 standards • Extremely tamper resistant • Compatible with: —PAN-WAY Snap-On Faceplates — Any U.S. Standard Screw-On Electrical/Communication Faceplates Std. Ctn. Qty. Part Number NEW! TE70B A=8.60in² 2.70" 4.10" Part Number Std. Ctn. Qty. Colors◆ 10 ft. lengths TE70BIW10 40 ft. Off White Type TE-70 Raceway Base 8 ft. lengths TE70BIW8 32 ft. TE-70 Raceway Base in 8 or 10 ft lengths supplied with pre-punched mounting holes. Type T-70 Raceway Cover T70CIW8 96 ft. T70CIW10 120 ft. Off White 80 ft. Lt. Gray TE70C TE-70 Raceway tamper resistant cover in 8 or 10 ft lengths. Type TE-70 Divider Wall TE70DW8 2.18" 64 ft. TE70DW10 ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. TE70DW ORDERING INF ORMAT ION: Order number of feet required, in multiples of Standard Length Increment. .84" Type TE Raceway Fittings Part Number TE70CFBIW-X TE70CFB TE70TF TE70OCC TE70CC TE70TD TE70RAF TE70IFC Description Colors ◆ Std. Pkg. Qty. Std. Ctn. Qty. Off White 10 pcs. 100 pcs. TE70CCIW-X Base Coupler Fitting (2 halves = 1 piece) Cover Coupler Fitting Off White 10 pcs 100 pcs. TE70ICFIW Inside Corner Fitting Off White 1 pc. 10 pcs. TE70TFIW Tee Fitting Off White 1 pc. 10 pcs. TE70TD Gray 1 pc. 10 pcs. TE70OCBIW Raceway Divider Insert (power and data applications) Separates power and data cabling within tee fitting Outside Corner Base Fitting Off White 1 pc. 10 pcs. TE70OCCIW Outside Corner Cover Fitting Off White 1 pc. 10 pcs. TE70RAFIW Right Angle Fitting Off White 1 pc. 10 pcs. TEC105IW End Cap Fitting Concentric conduit breakouts: ¾", ½" Off White 1 pc. 10 pcs. TE70OCB TEC105 ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F6 PAN-WAY ™ SURFACE RACEWAY SYSTEM Type TE-70 Raceway Accessories Std. Pkg. Qty. Std. Ctn. Qty. — 10 pcs. 100 pcs. Used to mount NEMA standard single gang electrical outlets and communication devices with either screw-on or snap-on single gang faceplates. Gray 10 pcs. 100 pcs. Used to mount NEMA standard single gang electrical outlets or devices with either screw-on or snap-on single gang faceplates when there are communications cables in the raceway. Gray 1 pc. 10 pcs. Holds wires in place. Will not interfere with cover installation. Gray 10 pcs. 100 pcs. Part Number Descr iption Color Mounting Bracket TMB105-X TMB105-X Brackets are attached to wall. TE-70 raceway is then snapped onto brackets. Device Mounting Bracket T70DB-X T70DB-X Hanging Box TE70HB Wire Retainer T70WR-X TE70HB ORDERING INFORMATION: Order number of feet required, in multiples of Standard Length Increment. T70WR-X PAN-WAY ™ Snap-On Faceplates for use with TE-70 Raceway • TE-70 is fully compatible with PAN-WAY Snap-On Faceplates • Available for Communication and Electrical Applications PAN-WAY Snap-On Faceplates Electrical/Communication Faceplates . . . . . . A3 Electrical/Communication Faceplates (with screw holes to mount a module frame) . A3 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F7 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for TE-70 Raceway TE-70 FILL CAPACITIES Use the wirefill configurations below along with the wirefill information contained on the next two pages as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. A=8.60 in ² Wirefill #1: TE-70 Raceway with no devices A=1.63 in ² A= 3.65 in² POWER DATA Wirefill #2: Power & Data using Hanging Box and Device Bracket Includes: Hanging Box, Divider Wall, Wire Retainer, T70P Faceplate, Snap-On Electrical/Communication Faceplate, Not shown for clarity: U.S. Standard Electrical Outlet, Standard Communication Module Frame and Communication Modules. Wirefill #3: Data Only using U.S. Standard Screw-On Electrical/Communication Faceplates Wirefill #4: Data Only using Snap-On Communication Faceplates (with screw holes to mount a module frame) Includes: Device Bracket, U.S. Standard Screw-On Electrical/Communication Faceplate, Standard Communication Module Frame, and Communication Modules Includes: Snap-On Communication Faceplate (with screw holes to mount a module frame), Standard Communication Module Frame, and Communication Modules For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F8 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for TE-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page F8 . SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes TE-70 FILL CAPACITIES ·Electrical MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) Fill Capacity Table for: ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP Electrical Cables Voice Grade Cables Data Gr ade Cables AWG 24 AWG UTP CM/CMR 24 AWG UTP CM 14 12 10 2 pr 3 pr 4 pr 25 pr Cat. 5 4 pr See Fill # THHN/T90 DIA.= 0.120 DIA.= 0.150 DIA.= 0.190 DIA.=0.422 DIA.=0.217 0.105 0.122 0.153 FILL FILL FILL FILL FILL MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Wirefill Configurations Wirefill #1: TE-70 with No Devices Wirefill #2: Power & Data u sin g Hangin g Box & Device Bracket 1 28 24 20 304 456 195 292 121 182 25 37 93 140 2A 17 14 14 58 87 37 55 23 35 5 7 18 26 2B ** ** ** 129 194 83 124 52 77 10 16 39 59 Wirefill #3: Data On ly u sin g U.S. Standard Screw-On Faceplates (see page F8) 3 ** ** ** 252 378 161 242 100 151 20 31 77 116 Wirefill #4: Data On ly u sin g Snap-On Commun ication Faceplates (with screw holes to m ount a modu le frame) (see page F8) 4 ** ** ** 293 439 187 281 117 175 24 35 89 134 NOTE: See p ag e xiv-xv for further explanation of wirefill data. ** Not power configuration Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP Raceway Channel Wirefill Configur ations ·1A STP Data Grade Cables 22 AWG UTP CM 22 AWG STP CM 25 pr 4 pr 25 pr 4 pr 24 AWG STP CM 25 pr 4 pr See Fill # DIA.=0.512 1A 22 AWG STP CM DIA.=0.250 DIA.= 0.544 DIA.= 0.234 DIA.=0.635 DIA.=0.286 DIA.=0.430 FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 17 25 70 105 15 22 80 120 11 16 54 80 24 36 2A 3 5 13 20 3 4 15 23 2 3 10 15 4 7 2B 7 11 30 45 6 9 34 51 5 7 23 34 10 15 Wirefill #3: Data Only using U.S. Standard Screw-On Faceplates (see page F8) 3 14 21 58 87 12 18 66 99 9 13 44 67 20 29 Wirefill #4: Data Only using Snap-On Commu nication Faceplates (with screw holes to moun t a modu le fram e) (see page F8) 4 16 24 67 101 14 21 77 115 10 16 52 77 23 34 Wirefill #1: TE-70 with No Devices Wirefill #2: Power & Data u sing Hang in g Box & Device Bracket NOT E: See p age xiv-xv for further explanation of wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F9 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for TE-70 Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference wirefill configurations on page F8 . SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) TE-70 FILL CAPACITIES Fill Capacity Table for: ·Coax Cables Coax Cables RG6/u RG11/u RG58/u RG59/u RG62A/u See DIA.=0.270 DIA.=0.405 DIA.=0.193 DIA.=0.242 DIA.=0.242 Fill # FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Wirefill Configurations 1 60 90 27 40 118 176 75 112 75 112 2A 11 17 5 8 22 33 14 21 14 21 2B 26 38 11 17 50 75 32 48 32 48 Wirefill #3: Data Only using U.S. Standard Screw-On F aceplates (see page F8 ) 3 50 75 22 33 97 146 62 93 62 93 Wirefill #4: Data Only using Snap-On Commu nication Facep lates (with screw holes to moun t a mod ule frame) (see page F8 ) 4 58 87 26 39 113 170 72 108 72 108 Wirefill #1: TE-70 with No Devices Wirefill #2: Po wer & Data using Hang ing Box & Device Bracket NOT E: See page xiv-xv for further explanation of wirefill data. Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Fiber Optic Cables (62.5/125mm ) Signal Cables 2 Strand 4 Strand 6 Strand 18AWG 20 AWG 22 AWG 24 AWG See DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 DIA.=0.057 DIA.=0.050 DIA.=0.044 Fill # FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX Raceway Channel Wirefill Configurations Wirefill #1: TE-70 with No Devices Wirefill #2: Power & Data u sin g Hangin g Box & Device Bracket 1 143 215 143 215 99 149 1006 1509 1349 2023 1753 2629 2264 3395 2A 27 41 27 41 19 28 191 286 256 383 332 498 429 644 572 859 744 1116 961 1441 2B 61 91 61 91 42 63 427 640 Wirefill #3: Data On ly u sin g U.S. Stan dard Screw-On Faceplates (see page F8) 3 118 178 118 178 82 123 833 1249 1117 1675 1451 2177 1874 2811 Wirefill #4: Data On ly u sin g Snap-On Commun ication Faceplates (with screw holes to m ount a m odu le frame) (see page F8) 4 138 206 138 206 96 143 967 1451 1297 1946 1686 2528 2177 3265 NOT E: See page xiv-xv for further explanation of wirefill data. Raceway Cutting Instructions: For small quantities, use a fine tooth handsaw. For larger quantities use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T or 100T; .090" thickness, .125" kerf. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) F10 G PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ T Surface Raceway Type T for Power and Communications Cabling (including Fiber Optic Cables) PAN-WAY Type T Surface Raceway provides a complete system for routing, protecting and terminating both your communications and power cabling systems. The multi-channel design keeps electrical and communications cables separated. This gives you the flexibility to install power cables first, then easily add communication cables later. Type T Raceway is tamper-resistant while also allowing you access for moves, adds and changes. Panduit PAN-WAY T Raceway provides the following key benefits: • Large capacity multi-channel raceway for power and communications applications • Superior tamper resistance, ideal for school and university applications • Two sizes to match your application needs • Power Rated to 600V (UL) meets new UL5A standards , 300V (CSA) meets CSA 22.2 No. 62-93 standards • Wide selection of fittings to speed installation • A selection of molded covers for power and/or communications cabling Compatible with: • Standard communication module frames used with PAN-WAY faceplates • PAN-WAY Snap-On Faceplates for communications cabling • Most manufacturers’ standard faceplates • A selection of Pre-cut Covers are available for mounting standard NEMA electrical outlets and faceplates (for T130 only) For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G1 PAN-WAY ™ SURFACE RACEWAY SYSTEM Table of Contents PAN-WAY ™ Type T Raceway Page T130 and T170 Raceway Raceway Base & Cover . . . . . . . . . . . . . . G9 Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . G4-G7 Fill Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . G13-G16 1 2 3 4 PAN-WAY Type T Raceway Raceway Accessories . . . . . . . . . . . . . . . . . . . . . . . . .G9 PAN-WAY Type T Raceway Type T130 & T170 Fittings . . . . . . . . . . . . . . . . . . . . .G10 PAN-WAY Type T Box & Pre-Cut Covers for NEMA Faceplates Type T Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G10 Pre-Cut Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G10 PAN-WAY Type T Snap-On Modular Furniture Faceplate Pre-Cut Covers Pre-Cut Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G11 PAN-WAY Type T130 Hanging Device Bracket & Molded Covers Device Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G11 Molded Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G12 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G2 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ Type T Raceway Roadmap T170 System T130 System CONFIGURATIONS 1 2 3 4 See page G4-G7 T130 Base pg. G9 T170 Base pg. G9 PAN-WAY Electrical Outlets pg. A4 PAN-WAY ™ Electrical/Communication Faceplates pg. A3-A4 PAN-WAY Electrical/Communication Faceplates pg. A3-A4 PAN-WAY Pre-Cut Covers pg. G10 PAN-WAY Electrical/Communication Faceplates pg. A3-A4 Standard Communications Module Frame T170 Cover pg. G9 Standard Communication Faceplate PAN-WAY ™ Electrical Outlets pg. A4 T130 System T130 Cover pg. G9 PAN-WAY T130 Molded Covers pg. G11-G12 T130 Fittings pg. G10 T170 Fittings pg. G10 PAN-WAY Electrical Outlets pg. A4 T170 System PAN-WAY Electrical/Communication Faceplates pg. A3-A4 Standard Communications Module Frame For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G3 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ Type T130 Raceway Configurations 1 Base: page G9 Cover: page G9 Fittings: page G10 T-130 Alternative — T130 Snap-On Electrical/Communications Faceplates 1 2 4 1 3 3 1 5 5 4 5 Data & Power 4 Data Only Power Only 3 2 • Snap-On Faceplates provide a superior appearance (no screws required) • Can use most manufacturers’ communication module frames (see chart on page vii) B 3.30 6.82 — See Page X X X G11-G12 X X X vii A4 X X X G12 X X X G9 1. T 130 Snap-On Electrical/Communication Faceplate(s) (T130RMC2 shown) 2. Standard Communication Module Frame X 3. 4. PAN-WAY Electrical Outlet (ERU20 shown) (2) Gangable Device Mounting Brackets (T130DBD shown) 5. Divider Wall (TD688 shown) Alternative — T130 Snap-On Covers for Modular Furniture Faceplates 3 3 1 2 4 4 5 6 1 3 Data & Power Data Only • Compatible with modular furniture faceplates with a cutout dimension 2.42" x 4.06" • Panduit ® Styles available, for more information refer to bottom of page xii 7 Components Required 3 Data & Power 2 A 3.94 — 7.67 Data & Po wer Data & Power Shown Areas (in²) Data & Power Data Only Power Only Po wer Only Components Required 2 Data Only 1 Data Only TYPE T130 RACEWAY CONFIGURATIONS Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax, or any low voltage cable; power cables (up to 600V). See Page X G11 X X X X G11 — A4 G11 G9 G10 2 Areas (in²) Data & Power Data Only A 4.00 — B 4.55 10.34 1. T 130 Snap-On Electrical/Communication Faceplate (for modular furniture faceplates) (T130TRMC shown) 2. T 130 Punched Cover (T 130K1 shown) 3. Most manufacturers’ modular furniture faceplates 4. PAN-WAY Electrical Outlet (ERU20 shown) 5. Hanging Device Bracket (T130DB-X shown) 6. Divider Wall (TD688 shown) 7. Cover Couplers (TCFC 130 shown) X X X Note: For power only applications see configuration #1 above or configuration #3 shown on next page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G4 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ T130 Raceway Configurations Cont’d Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax, or any low voltage cable; power cables (up to 600V). Base: page G9 Cover: page G9 Fittings: page G10 T-130 2 1 5 1 3 3 5 1 2 5 7 1 7 7 4 4 4 8 Power Only Data & Power 5 3 2 Data Only • U.S. standard screw-on electrical faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) Areas (in²) Data & Power Data Only Power Only 4 A 2.56 — 2.56(x2) B 2.56 2.56(x2) — U.S. Standard Screw-On Electrical/Comm. Faceplate(s) (CPG shown) X 2. Standard Communication Module Frame X 3. 4. PAN-WAY Electrical Outlet (ERU20 shown) Type T Box (TB5883 shown) 5. Pre-cut cover (T130G shown) 6. T 130 cover coupler fitting (TCFC130 shown) 7. Wire retainer (TWR130 shown) 8. Divider Wall (T D688 shown) X X X Data & Po wer 1. Components Required 6 Po wer Only Data Only 1 See Page X X A3 X X X X X X X vii A4 G10 G10 G10 G9 G9 X X X X U.S. Standard Screw-On Communication Faceplates 5 4 2 1 2 3 1 Data Only 4 Areas (in²) Data Only A — B 2.56(x2) Components Required 1. Most Mfg. U.S. Standard Screw-On Comm. Faceplate(s) 2. Manufacturers’ inserts and/or modules 3. Type T Box (TB5883 shown) 4. Pre-cut cover (T130G shown) 5. T 130 cover coupler fitting (TCFC130 shown) Data Only • Uses most manufacturers’ communication faceplates • Panduit ® Styles available, for more information refer to page xii See Page X X X X X — — G10 G10 G10 Note: For power only or power and data applications use power components from configuration #3 above. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G5 TYPE T RACEWAY CONFIGURATIONS PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 3 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ Type T170 Raceway Configurations 1 Base: page G9 Cover: page G9 Fittings: page G10 T-170 Alternative — T170 Snap-On Electrical/Communications Faceplates This solution is not available for T170 Alternative — T170 Snap-On Covers for Modular Furniture Faceplates 3 2 1 • Compatible with modular furniture faceplates with a cutout dimension = 1.375" x 2.71" • Panduit ® Styles available, for more information refer to bottom of page xii 2 1 Data Only Ar eas (in²) Data Only A — B 13.66 Components Requir ed 1. T170 Punched Cover (T170K1 show n) 2. Most manufacturers’ modular furniture faceplates 3. Cover Couplers (T CFC170 shown) X X X Data & Power 2 Data On ly TYPE T170 RACEWAY CONFIGURATIONS Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax, or any low voltage cable; power cables (up to 600V). See Page X G11 — G10 Note: For power only applications see configuration #3 shown on next page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G6 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ T170 Raceway Configurations Cont’d Application: Routing communication cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax, or any low voltage cable; power cables (up to 600V). T-170 PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 5 1 2 6 3 1 5 6 3 5 7 7 8 4 4 2 1 6 7 Data & Power Power Only 5 Data Only • U.S. Standard Screw-On Electrical/Communication faceplate is used • Can use most manufacturers’ communication module frames (see char t on page vii) 1 5 U.S. Standard Screw-On Electrical/Comm. Faceplate(s) (CPG shown) X 2. Standard Communication Module Frame X 3. PAN-WAY Electrical Outlet (ERU20 shown) Areas (in²) Data & Power Data Only Power Only A 4.25 — 4.25(x2) B 4.25 4.25(x2) — 4. Type T Box (TB5583 shown) 5. 6. Pre-cut cover (T170G shown) T 170 cover coupler fitting (TCFC170 shown) 7. Wire retainer (TWR170 shown) 8. Divider Wall (T D388 shown) X X X Data & Power 1. Components Required 6 Power Only Data Only 3 2 4 1 See Page X X A3-A4 X X X X X X X vii A4 G10 G10 G10 G9 G9 X X X X U.S. Standard Screw-On Communication Faceplates 2 1 4 1 2 6 4 • Panduit ® Styles available, for more information refer to page xii 3 Components Required 5 Areas (in²) Data Only A — B 4.25(x2) 1. Most Mfg. U.S. Standard Screw-On Comm. Faceplate 2. Manufacturers’ inserts and/or modules 3. Type T Box (TB5883 shown) 4. Pre-cut cover (T170G shown) 5. T 170 cover coupler fitting (TCFC170 shown) 6. Wire retainer (TWR170 shown) Data On ly Data Only See Page X X X X X X — — G10 G10 G10 G9 Note: For power only or power and data applications use power components from configuration #3 above. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G7 TYPE T RACEWAY CONFIGURATIONS 3 Base: page G9 Cover: page G9 Fittings: page G10 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ Surface Raceway Applications A wide selection of fittings and device covers are available to speed installation and term inations. With a large capacity and multichannel capability, PAN-WAY Type T Surface Raceway can integrate both power and communication cabling systems while maintaining a neat and professional appearance throughout a testing lab. To further organize cables, use Type T Raceway in conjunction with PANDUCT ® Type G Wir ing Duct to route and conceal device cable slack. PAN-WAY Type T Surface Raceway, with it’s durable construction, can be used in industrial as well as office applications. NEW! T130RMC2 page G12 Type T Raceway allows you to run both communications and electrical cables anywhere they are needed on the production floor. The new Type T130 Molded Covers cover 106 or rectangular outlets and will accept communications module frames (106 or rectangular frame) for multichannel applications For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G8 PAN-WAY ™ SURFACE RACEWAY SYSTEM PAN-WAY ™ Type T Surface Raceway PAN-WAY Type T Surface Raceway is a large capacity, multi-channel system used to route, protect, and conceal data, voice, video and power cabling systems. Type T System Benefits: • Power rated to 600V(UL), 300V(CSA) meets new UL5A standard and CSA 22.2 No. 62-93 standards • Superior tamper resistance for School & University applications • Modular divider wall keeps power and data cables separated NEW Sizes! Std. Ctn. Qty. Part Number A=10.96in² Part Number 8 ft. lengths 2.70" Std. Ctn. Qty. Colors ◆ 10 ft. lengths Type T130 Raceway Base 5.10" TB130 TB130IW8 32ft. TB130IW10 40ft. Off White 64ft. TC130IW10 80ft. Off White 32ft. TB170IW10 20ft. Off White 64ft. TC170IW10 60ft. Off White 64ft. TD6810 80ft. Gray ONLY Type T130 Raceway Cover TC130IW8 A =14.63in² 2.70" Type T170 Raceway Base TB170IW8 6.70" TB170 Type T170 Raceway Cover TC170IW8 Divider Wall 2.30 9 TD688 ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. TD688 .77 6 ORDERING INFORMATION : Order number of feet required, in multiples of Standard Length Increment. Type T Raceway Accessories Used with Raceway Std. Pkg. Qty. Std. Ctn. Qty. Brackets are attached to wall. Type T raceway is then snapped onto brackets. Can be used as required anywhere along the raceway. T130 10 pcs. 100 pcs. T170 10 pcs. 100 pcs. Holds wires in place. Will not interfere with cover installation. To add cables, simply remove cover and loosen one side of the retainer. T130 10 pcs. 100 pcs. T170 10 pcs. 100 pcs. Par t Number Description Mounting Bracket TMB130-X TMB170-X TMB Wire Retainer TWR130-X TWR170-X TWR ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G9 PAN-WAY ™ SURFACE RACEWAY SYSTEM Type T Raceway Fittings TCFB (at right) TCFC (at left) Part Number Part Number T130 Colors ◆ Std. Pkg. Qty. Std. Ctn. Qty. T170 Base Couplers TCFB3070IW-X TCFB3070IW-X Off White 10 pcs. 100 pcs. TCFC170IW-X Off White 10 pcs. 100 pcs. TIC170IW Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. TOCC170IW Off White 1 pc. 10 pcs. TRA170IW Off White 1 pc. 100 pcs. TT170IW Off White 1 pc. 10 pcs. TEC170IW Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Cover Couplers TCFC130IW-X Inside Corner Fitting TIC TOCB TIC130IW Outside Corner Fitting Base TOCB130IW TOCB170IW Outside Corner Fitting Cover TOCC130IW Right Angle Fitting TRA TOCC TRA130IW Tee Fitting TT130IW End Cap Fitting TEC130IW Reducer Fitting TT T170 to T130 TEC TR170X130IW T130 Entrance End TEE130IW ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and TR TEE130 WH (White). Contact factory for details. ORDERING INFOR MATION: Order number of feet required, in multiples of Standard Length Increment. PAN-WAY ™ Type T Box and Pre-Cut Cover (for Mounting Standard NEMA Faceplates) Part Number TB5583-V Description Std. Pkg. Qty. Std. Ctn. Qty. 5 pcs. 60 pcs. Type T Box TB5583-V 3.28" (83.5mm) mounting holes, 2.17" (55mm) deep. For use with single gang NEMA standard electrical devices and faceplates. This box is used with U.S. electrical outlets. Raceway Box Strain Relief TBSR-Q Snaps onto TB5583-V Type T Box. Required to support cable 25 pcs. connections in vertically mounted raceway applications. TBSR-Q Part Number Par t Number T130 Colors ◆ — Std. Pkg. Qty. Std. Ctn. Qty. 1 pc. 10 pcs. T170 Pre-Cut Cover for Type T Box & NEMA Faceplates T130GIW Pre-Cut Cover for Type T Box & NEMA Faceplates • Cover Length = 7.05" (179mm) • Cutout Dimension = 2.42" x 4.06" (61.5 x 103mm) T170GIW Off White Used with all standard NEMA electrical faceplates. Use with 2 Cover Couplers. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMAT ION: Order number of feet required, in multiples of Standard Length Increment. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G10 PAN-WAY ™ SURFACE RACEWAY SYSTEM Snap-On Faceplate Pre-Cut Covers (for Snap-On Modular Furniture Faceplates) Part Number Part Number T130 Std. Pkg. Qty. Std. Ctn. Qty. 1 pc. 10 pcs. 1 pc. 10 pcs. 10 pc. 1 pcs. Colors ◆ T170 Pre-Cut Cover for One Snap-On Modular Furniture Faceplate K1 T130K1IW K2 T170K1IW Off White Pre-Cut Cover for Two Snap-On Modular Furniture Faceplates T130K2IW T170K2IW Off White Pre-Cut Cover for Three Snap-On Modular Furniture Faceplates T170K3IW Off White Pre-cut cover for use with Snap-On Modular Furniture Faceplates. Use with two Cover Couplers shown on page G10 . Cover Lengths = 4.92" (125mm) K3 ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INF ORMATION: Order number of feet required, in multiples of Standard Length Increment. Cutout Dimensions: 1.345" to 1.405" (34.2mm to 35.7mm) 2.670" to 2.750" (60.1mm to 72.4mm) Maximum Panel Thickness: .090" (2.29mm) T130 Hanging Device Bracket & Molded Covers (for T130 Size Raceway ONLY) Part Number Std. Pkg. Qty. Std. Ctn. Qty. Description Color◆ Used to quickly mount NEMA standard electrical receptacles (including GFCI) in T130 Raceway. Must be used with appropriate T130 Molded Cover. Lt. Gray ONLY 10 pcs. 100 pcs. Lt. Gray ONLY 10 pcs. 100 pcs. Hanging Device Bracket T130DB-X NEW! T130DBD-X NEW! T130DB-X “Gangable” Device Bracket T130DBD-X Two (2) “Gangable” Device Brackets can be interlocked to mount multiple electrical and/or data devices in T130 base in multi-channel applications. Duplex Electrical Device Molded Cover T130DMCIW T130DMC NEW! T130DMC2 NEW! Covers NEMA standard 106 duplex electrical devices. Replaces faceplate and pre-cut raceway cover. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Off White 1 pc. 10 pcs. Double Duplex Electrical Device Molded Cover T130DMC2IW Covers 2 NEMA standard 106 duplex electrical devices. Replaces faceplate and pre-cut raceway cover. Rectangular Electrical Device Molded Cover T130RMCIW T130RMC T130RMC2 NOTE: Can also be used for Communication Module Frames Covers NEMA standard rectangular electrical devices. Replaces faceplate and pre-cut raceway cover. For use with T130DBD-X and TD688 divider wall. Double Rectangular Electrical Device Molded Cover T130RMC2IW Covers 2 NEMA standard rectangular electrical devices. Replaces faceplate and pre-cut raceway cover. For use with T130DBD-X and TD688 divider wall. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INFOR MATION : Order number of feet required, in multiples of Standard Length Increment. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G11 PAN-WAY ™ SURFACE RACEWAY SYSTEM T130 Hanging Device Bracket & Molded Covers (cont.) (for T130 Size Raceway ONLY) Part Number Description Color◆ Std. Pkg. Qty. Std. Ctn. Qty. Twist Lock Electrical Device Molded Cover T130LMCIW T130LMC T130TMC Covers NEMA standard twist lock electrical devices. Replaces faceplate and pre-cut raceway cover. Off White 1 pc. 10 pcs. Off White 1 pcs. 10 pcs. Covers NEMA standard duplex electrical devices and Off White provides proper sized opening to accept Snap-On Modular Furniture Faceplates. 1 pc. 10 pcs. Communications Device Molded Cover T130TMCIW Provides proper sized opening to accept Snap-On Modular Furniture Faceplates. Communications and Duplex Electrical Device Molded Cover T130TDMCIW Communications and Rectangular Electrical Device Molded Cover T130TDMC T130TRMC T130TRMCIW NEW! Covers NEMA standard rectangular electrical Off White devices and provides proper sized opening to accept Snap-On Modular Furniture Faceplates. 1 pc. 10 pcs. 45X45 Device Cover (Accepts standard 45X45 modules*) T130FFMCIW Four 45X45mm devices snap into cover. Off White 1 pc. 10 pcs. ◆ All parts listed in Off White (IW) color. To order other colors substitute EI (Electric Ivory), IG (Light Gray), and WH (White). Contact factory for details. ORDERING INFORMATION: Order number of feet required, in multiples of Standard Length Increment. T130FFMC * Modules are not available from Panduit. 45x45 Modules (French) shown in T130FFMC.* For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G12 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for T Raceway Use the wirefill configurations below, along with the wirefill information contained in the following pages, as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. 1 2A 2B A= 10.96 in² A= 2.56 in² A= 2.56 in² Wirefill #1: T130 Raceway with no devices Wirefill #2: T130 Raceway—Power & Data using T Box & U.S. Standard Screw-On Electrical/Communication Faceplates Includes: TB5583-V Box, Divider Wall, Wire Retainer, U.S. Standard Screw-On Electrical/Communication Faceplate; Data faceplate, communication module frame and modules (not shown) 3 A= 10.34 in ² Wirefill #3: T130 Raceway—Data Only using Most Manufacturers’ Modular Furniture Faceplates Includes: Most Manufacturers’s Modular Furniture Faceplate, T130K1 Punched Cover and modules 4 A= 3.72 in ² 4 A= 3.52 in² Wirefill #4: T130 Raceway—Power & Data using T130RMC2 Molded Cover Includes: T130RMC2 Molded Cover, Divider Wall, Wir e Retainer, Gangable Device Bracket, U.S. Standard Electrical Outlet, Standard Communication Module Frame & Modules For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G13 TYPE T FILL CAPACITIES T130 Raceway PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for T Raceway TYPE T FILL CAPACITIES Use the wirefill configurations below, along with the wirefill information contained in the following pages, as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. T170 Raceway 5 6A 6B A= 14.63 A= 4.25 in² A= 4.25 in² Wirefill #5: T170 Raceway with no devices Wirefill #6: T170 Raceway—Power & Data using T Box & U.S. Standard Screw-On Electrical/ Communication Faceplates Includes: TB5583-V Box, Divider Wall, Wire Retainer, U.S. Standard Screw-On Electrical/Com munication Faceplate; Data faceplate (not shown) 7 A= 13.66 in ² Wirefill #7: T170 Raceway—Data Only using Most Manufacturers’ Modular Furniture Faceplates Includes: Most Manufacturers’ Modular Furniture Faceplates, T170K1 Punched Cover and m odules Raceway Cutting Instructions: For small quantities, use a fine tooth handsaw. For larger quantities use a plastic cutting saw blade for clean, burr-free cuts. Recommend: Carbide 80T or 100T; .090" thickness, .125" kerf. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G14 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for T Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference configurations on page G13 thru G14 . SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) Electrical Cables Voice Grade Cables Data Grade Cables AWG 24 AWG UTP CM/CMR 24 AWG 14 12 10 2 pr 3 pr 4 pr 25 pr THHN/T90 DIA.= 0.120 DIA.= 0.150 DIA.= 0.190 DIA.=0.422 FILL FILL FILL FILL See 0.105 0.122 0.153 Fig. MAX MAX MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 31 28 26 388 582 248 372 155 232 31 47 Raceway Channel Configurations Wire fill # 1: T 130 with No Device s Wire fill # 2: T 130 Po we r & Da ta u sin g T-B ox & U.S. Stand ard Screw-On Elec trical /Co mm un ication F acep lates Wirefill #3: T 130 Data Only using Modular F urniture Faceplates Wire fill # 4: Power & Data u sin g the T13 0TR MC2 Mol ded Co ver Wire fill # 5: T 170 with No Device s Wire fill # 6: T 170 Po we r & Da ta u sin g T-B ox & U.S. Stand ard Screw-On Elec trical /Co mm un ication F acep lates Wirefill #7: T 170 with Modular Furniture Facep late TYPE T FILL CAPACITIES Fill Capacity Table for: ·Electrical ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP UTP CM Cat. 5 4 pr DIA.=0.217 FILL SPEC MAX 119 178 2A 17 15 14 91 136 58 87 36 54 7 11 28 42 2B — — — 91 136 58 87 36 54 7 11 28 42 3 — — — 353 530 226 339 141 211 29 43 108 162 4A 4B 5 20 — 31 16 — 28 17 — 26 131 124 518 197 186 777 84 79 331 126 119 497 52 49 207 78 74 310 10 10 42 15 15 63 40 38 158 60 57 237 6A 20 18 16 150 226 96 144 60 90 12 18 46 69 6B — — — 150 226 96 144 60 90 12 18 46 69 7 — — — 483 725 309 464 193 289 39 59 148 222 Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP ·1A STP Data Gr ade Cables Raceway Channel Configurations Wi re fill # 1: T 130 with No Devic es 24 AWG STP CM 22 AWG 25 pr 4 pr 25 pr DIA.=0.512 DIA.=0.250 DIA.= 0.544 FILL FILL FILL See Fig. SPEC MAX SPEC MAX SPEC MAX 1 21 32 89 134 19 28 UTP CM 22 AWG STP CM 1A 22 AWG STP CM 4 pr 25 pr 4 pr DIA.= 0.234 DIA.=0.635 DIA.=0.286 DIA.=0.430 FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX 102 153 14 21 68 102 30 45 Wi re fill # 2: T 130 Po we r & D ata u sin g T-B ox & U.S. Stan dard Sc rew-On Ele ctrica l/Co mm un icatio n F acep lates 2A 5 7 21 31 4 7 24 36 3 5 16 24 7 11 2B 5 7 21 31 4 7 24 36 3 5 16 24 7 11 Wirefill #3: T130 Data Only using Modular F urn itu re Faceplates 3 19 29 81 122 17 26 93 139 13 19 62 93 28 41 4A 4B 5 7 6 28 10 10 43 30 28 119 45 43 179 6 6 25 9 9 38 34 32 136 51 49 204 4 4 18 7 6 28 23 23 91 34 32 137 10 9 40 15 14 60 Wi re fill # 4: Power & Da ta u sin g the T13 0TR MC2 Mo lded Co ver Wi re fill # 5: T 170 with No Devic es Wi re fill # 6: T 170 Po we r & D ata u sin g T-B ox & U.S. Stan dard Sc rew-On Ele ctrica l/Co mm un icatio n F acep lates 6A 8 12 35 52 7 11 40 59 5 8 26 40 12 18 6B 8 12 35 52 7 11 40 59 5 8 26 40 12 18 Wirefill #7: T170 with Modular Furnitu re Faceplate 7 27 40 111 167 24 35 127 191 17 26 85 128 38 56 NOTE: See p age xiv-xv for further explanation of the wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G15 PAN-WAY ™ SURFACE RACEWAY SYSTEM Fill Capacities for T Raceway This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. Reference configurations on page G13 thru G14 . TYPE T FILL CAPACITIES SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temp. rise test (electrical) Fill Capacity Table for: ·Coax Cables Coax Cables RG6/u RG11/u RG58/u RG59/u RG62A/u DIA.=0.270 DIA.=0.405 DIA.=0.193 DIA.=0.242 DIA.=0.242 FILL FILL FILL FILL FILL See Fig. SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 77 115 34 51 150 225 95 143 95 143 Raceway Channel Configurations Wirefill #1: T 130 with N o D evices Wirefill #2: T 130 Power & Data u sing T-Bo x & U.S. Sta nd ard Screw-On Electrical/C om mu n icati on Fa cepl ates Wirefill #3: T130 Data Only using Mod ular Furniture Faceplates Wirefill #4: Power & Data us ing th e T 130T RM C2 M old ed Cov er Wirefill #5: T 170 with N o D evices Wirefill #6: T 170 Power & Data u sing T-Bo x & U.S. Sta nd ard Screw-On Electrical/C om mu n icati on Fa cepl ates Wirefill #7: T170 with Modular F urniture Faceplate 2A 18 27 8 12 35 53 22 33 22 33 2B 18 27 8 12 35 53 22 33 22 33 3 70 105 31 47 137 205 87 130 87 130 4A 4B 5 28 34 102 41 50 153 12 15 45 18 22 68 54 66 200 81 98 300 34 42 127 52 63 191 34 42 127 52 63 191 6A 30 45 13 20 58 87 37 55 37 55 6B 30 45 13 20 58 87 37 55 37 55 7 95 143 42 64 187 280 119 178 119 178 Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Fiber Optic Cables (62.5/125mm) Raceway Channel Configurations Wire fill # 1: T 130 with N o Device s Wire fill # 2: T 130 Po wer & Da ta u sin g T-B ox & U.S. Stand ard Screw-On Elec trical /Co mm un ication F acep lates Wirefill #3: T 130 Data Only using Modular F urniture Faceplates Wire fill # 4: Power & Data u sin g the T13 0TR MC2 Mold ed Co ver Wire fill # 5: T 170 with N o Device s Wire fill # 6: T 170 Po wer & Da ta u sin g T-B ox & U.S. Stand ard Screw-On Elec trical /Co mm un ication F acep lates Wirefill #7: T 170 with Modular Furn iture Facep late Signal Cables 2 Strand 4 Strand 6 Strand 18AWG 20 AWG 22 AWG 24 AWG DIA.=0.175 DIA.=0.175 DIA.=0.210 DIA.=0.066 DIA.=0.057 DIA.=0.050 DIA.=0.044 FILL FILL FILL FILL FILL FILL FILL See Fig. SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX 1 182 274 182 274 127 190 1282 1923 1719 2578 2234 3351 2885 4327 2A 43 64 43 64 30 44 299 449 401 602 522 783 674 1011 2B 43 64 43 64 30 44 299 449 401 602 522 783 674 1011 3 166 249 166 249 115 173 1167 1751 1565 2348 2034 3051 2627 3940 4A 4B 5 66 80 243 99 120 365 66 80 243 99 120 365 46 55 169 68 83 254 462 693 619 929 561 842 753 1129 1711 2567 2294 3442 805 1208 1040 1559 978 1468 1263 1895 2982 4473 3851 5776 6A 71 106 71 106 49 74 497 746 667 1000 866 1299 1119 1678 6B 71 106 71 106 49 74 497 746 667 1000 866 1299 1119 1678 7 227 341 227 341 158 237 1598 2397 2142 3214 2784 4176 3595 5393 NOTE: See p ag e xiv-xv for further explanation of the wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) G16 H SURFACE RACEWAY SYSTEM ACCESSORIES PAN-WAY ™ Surface Raceway Cutting Tool Part Number Std. Pkg. Qty. Description Surface Raceway Cutting Tool SRT Used to easily cut all sizes of Types LDP, LD2P, LD, LDS, CD and PD raceway. Leaves a clean, burr-free end on raceway. Can also be used to cut plastic conduit. 1 pc. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package Quantity. • Rugged, ratchet-action tool cuts surface raceway Floor Guard Par t Number Length Overall Size W xH Wire Slot Size W xH Color Std. Pkg. Qty. Elec. Ivory Brown Safety Yellow Black 6 ft. 6 ft. 6 ft. 6 ft. Elec. Ivory Brown Safety Yellow Black 50 50 50 50 ft. ft. ft. ft. Elec. Ivory Brown Safety Yellow Black 30 30 30 30 ft. ft. ft. ft. Elec. Ivory Brown Safety Yellow Black 50 50 50 50 ft. ft. ft. ft. FG1 – For single, twisted pair cables • Routes cabling over carpet, concrete or tile to prevent tripping • Flexible vinyl material can be easily cut to length • Cables slip into slit on base • Adhesive mounting tape is supplied FG1EI6-A FG1BR6-A FG1YL6-A FG1BL6-A 6 ft. 6 ft. 6 ft. 6 ft. FG1EI50-A FG1BR50-A FG1YL50-A FG1BL50-A 50 50 50 50 ft. ft. ft. ft. 1.25" x .27" (31.8 x 6.9) .25" x .27" (6.4 x 4.3) FG3 – For multiple or larger cables FG3EI6S-A FG3BR6S-A FG3YL6S-A FG3BL6S-A 6 ft. 6 ft. 6 ft. 6 ft. FG3EI50-A FG3BR50-A FG3YL50-A FG3BL50-A 50 50 50 50 ft. ft. ft. ft. 2.44" x .47" (62.0 x 12.0) .68" x .28" (17.2 x 7.1) ORDERING IN FORMAT ION: Order number of feet required, in multiples Standard Package Quantity. Note: Mounting tape is pre-applied only to FG3 in 6 ft. lengths. Magnet Strip Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. FG3 – For multiple or larger cables • Mounts adhesive backed raceway to metal surfaces such as desks, cabinets, modular furniture, etc. • Flexible material can be easily cut to length FMS75X6 6 ft. roll x .75" wide for use with PD3, LDP3, LD3, CD3, CD5 Raceway 1 pc. 10 pcs. FMS100X6 6 ft. roll x 1.00" wide for use with PD6, LDP5, LDP10, LD5, LD10, CD10 Raceway 1 pc. 10 pcs. ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package Quantity. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) H1 I O pen Of fice Pr oducts PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE ™ Aluminum Outlet Pole PAN-POLE Aluminum Outlet Pole is an aesthetically pleasing dual channel pole for both power and communications outlets. The entrance fitting has been engineered to maintain the TIA/EIA required 1" bend radius for Category 5 and Fiber Optic Cabling. The PAN-POLE is tamper resistant to the end user, yet allows easy access to the installer for moves, adds, and changes. PAN-POLE Aluminum Outlet Pole provides a totally integrated horizontal cabling solution for High Performance Copper, UTP, ScTP, Coax, Fiber Optic and Power Cabling Systems. NEW! Available in 11 & 13 Foot Lengths PAN-WAY Snap-On Faceplates (with screw holes to mount a module frame) speed installation, lowering overall installed cost. Entry end bend radius fitting maintains 1" bend radius control of communication cable Panduit PAN-POLE provides the following key benefits: • Entry end bend radius control fitting, maintains the minimum 1" bend radius required under TIA/EIA 568-A and 569-A for high performance copper and fiber optic cabling systems • UL-5 Listed and CSA Certified • Tamper resistant plastic cover allows for customized placement of data outlets and is easy for the installer to cut and modify, reducing overall installation costs and costs associated with moves, adds, and changes • Dual channel aluminum pole provides complete separation of power and data eliminating the need for two separate poles ™ •reducing 2 colorsoverall available to complement surrounding decor IPAN-WAY Snap-On installed faceplates cost are easy to install For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I1 PAN-POLE ™ OPEN OFFICE SYSTEM Table of Contents Power & Communication Pole Page Communication Pole PAN-POLE ™ Aluminum Outlet Pole Power and Communications Pole . . . . . . . . . . . . . . I6 Communication Only Pole . . . . . . . . . . . . . . . . . . . . . . I6 Configurations . . . . . . . . . . . . . . . . . . . . . I4-I5 2 3 4 Accessories Standard Faceplate Bracket . . . . . . . . . . . . . . . . . . . . . I7 Standard Included Mounting Hardware . . . . . . . . . . . . I7 Data Installation Instructions . . . . . . . . . . . . . . . . . . . . .I8 Fill Capacity Information. . . . . . . . . . . . . . . . . . . . . I9-I11 PAN-WAY ™ Snap-On Faceplates Electrical/Communication Faceplates . . . . . . . . . . . . . A3 Electrical/Communication Faceplates (with screw holes for module frames) . . . . . . . . . . . . . A3 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I2 PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE ™ Aluminum Outlet Pole—Roadmap Maintains 1" Bend Radius Control of Communication Cables Standard Faceplate Bracket (accepts most Mfg. U.S. Screw-On Communication Faceplates) page I7 PAN-WAY ™ U.S. Standard Screw-On Electrical/Communication Faceplate page A3 Standard Communication Module Frame Standard Communication Module Frame PAN-WAY Snap-On Communication Faceplate (with screw holes to mount a module frame) page A3 PAN-POLE Communication Only Pole * page I6 Pre-wired for Power (20A Outlets) POWER POLE CONFIGURATIONS PAN-POLE Power and Communication Pole* page I6 2 3 4 See page I4 thru I5 * Data Hardware purchased separately. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I3 PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE ™ Aluminum Outlet Pole Configurations Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). 1 Components: pg. I6 Accessories: pg. I7 PAN-POLE PAN-WAY ™ Snap-On Electrical/Communication Faceplates 2 PAN-WAY Snap-On Communication Faceplates (with screw holes to mount a module frame) 1 2 1 Communication Only Pole Power & Communication Pole 2 Com ponents Required See Page 2.00 1. Snap-On Communication Faceplate (with screw holes to mount a module frame) (T70PGS shown) X X A3 2.70 2. Standard Communication Module Frame X X vii PAN-WAY U.S. Standard Screw-On Electrical/Communication Faceplates 1 2 3 1 Power & Communication Pole 2 Communication Only Pole • U.S. Standard screw-on faceplate is used • Can use most manufacturers’ communication module frames (see chart on page vii) Ar eas (in²) A Power & Communication Pole Data & Power .43 Communication Only Pole Data Only — Components Required 1. U.S. Standard Screw-On Electrical/Communication Faceplate(s) (CPG shown) X X A3 2. Standard Communication Module Frame 3. Device Mounting Bracket (T70SDB-X shown) X X X X vii I7 B 1.82 2.46 Comm . Only Pole 3 B Co mm. Only Pole Areas (in²) A Power & Communication Pole Data & Power .47 Communication Only Pole Data Only — Power & Co mm. Pole • Faceplate requires no device mounting bracket • Can use most manufacturers’ communication module frames (see chart on page vii) Power & Comm . Pole PAN-POLE ALUMINUM OUTLET POLE CONFIGURATIONS Configurations for this faceplate style not currently available See Page For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I4 PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE ™ Aluminum Outlet Pole Configurations Application: Routing low voltage cables and/or power cabling: Fiber Optic, Category 5, UTP, ScTP, Coax or any other low voltage cable; power cables (up to 600V). 4 PAN-POLE Components: pg. I6 Accessories: pg. I7 U.S. Standard Screw-On Communication Faceplates 1 3 1 Power & Communication Pole 3 Communication Only Pole Areas (in²) A Power & Communication Pole Data Only .43 Communication Only Pole Data Only — B 1.82 Comm. Only Pole Components Required Power & Comm. Pole • Uses most manufacturers’ NEMA standard 70mm communication faceplates • Panduit ® Styles available, for more information refer to page xii 1. U.S. Standard Screw-On Communication Faceplate(s) X X 2. Device Mounting Bracket (T70SDB-X shown) 3. Manufacturers’ inserts and/or communication modules X X X X See Page — I7 — 2.46 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I5 PAN-POLE ALUMINUM OUTLET POLE CONFIGURATIONS 2 PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE ™ Aluminum Outlet Pole Components PAN-POLE Power and Communication Pole 3 PAN-POLE Power and Communication Pole is a dual-channel aluminum pole for routing both power and communications cabling. 4 5 6 7 8 Std. Pkg. Qty. Part Number Std. Pkg. Qty. Par t Number 11 ft. lengths Colors 13 ft. lengths PAN-POLE Power & Communications Pole 1 PCPA11R20IW PCPA13R20IW 1 1 Off White PCPA11R20EI PCPA13R20EI 1 1 Elec. Ivory PAN-POLE Pole Assembly is supplied in 11 and 13 foot lengths for maximum ceiling heights of 10 or 12 feet. a 2 a = 11'2" or 13'2" b = 2.90" c = 1.77" d = 15.50" d 9 b c Standard furnished factory assembled pole configurations include the following: 1. Aluminum extruded base with blank plastic cover 2. Two (2) 20A factor y wired rectangular outlets with wiring fed through power channel to base of power entry box 3. Power entry box with 1/2", 3/4", and 1" conduit br eakouts 4. 8" removable plate for power wiring connections 5. Ground screw pre-mounted behind removable plate Standard furnished mounting hardware includes: 6. Entry end bend radius fitting for com munication cabling (two mounting screws included) 7. Ceiling T-bar bracket (two mounting screws included) 8. Two (2) ceiling tile trim plates 9. End cap with two pre-drilled holes 10.End cap floor grip pad Data hardware sold separately ORDERING INFORMATION: Order number of PAN-P OLE Aluminum Outlet Poles required. 10 PAN-POLE Communication Only Pole PAN-POLE Communication Only Pole is a single-channel aluminum pole for routing communication cabling. 6 7 8 Std. Pkg. Qty. Par t Num ber Part Number 11 ft. lengths Std. Pkg. Qty. Colors 1 1 Off White Elec. Ivory 13 ft. lengths PAN-POLE Communication Only Pole PCPA11IW PCPA11EI 1 1 PCPA13IW PCPA13EI PAN-POLE Pole Assembly is supplied in 11 and 13 foot lengths for maximum ceiling heights of 10 or 12 feet. a Standard furnished factory assembled pole configuration include the following: 1. Aluminum extruded base with blank plastic cover Standard furnished mounting hardwar e includes: 6. Entr y end bend radius fitting for communication cabling (two mounting screws included) 7. Ceiling T-bar bracket (two mounting screws included) 8. Two (2) ceiling tile trim plates 9. End cap with two pre-drilled holes 10. End cap floor grip pad 1 Data hardware sold separately ORDERING INFORMATION : Order number of PAN-POLE Aluminum Outlet Poles required. a = 11' or 13' b = 2.90" c = 1.77" 9 b c 10 I6 For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) PAN-POLE ™ OPEN OFFICE SYSTEM PAN-POLE Accessories Par t Number Description Colors Std. Pkg. Qty. Std. Ctn. Qty. 1 pc. 10 pcs. Standard Faceplate Bracket (for Data) T70SDB-X T70SDB-X Used to mount NEMA standard single gang screwon communication faceplates (not for use with snap-on faceplates). Gray ONLY ORDERING INFORMATION: Order number of pieces required, in multiples of Standard Package Quantity. Standard Included Mounting Hardware Ceiling T-bar bracket attaches PAN-POLE to drop ceiling T-bar (supplied with two thumb screws). Entry End Bend Radius Control Fitting protects the integrity of communication cabling (supplied with two mounting screws). Two ceiling tile trim plates provide an aesthetically pleasing appearance. End Cap Fitting with pre-drilled screw holes provides sturdy base (screws not included). End cap with supplied adhesive backed grip pad applied provides sturdy base for easy-tomove car pet mount applications. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I7 PAN-POLE ™ OPEN OFFICE SYSTEM 2 ™ Installing PAN-WAY Snap-On Faceplates into the PAN-POLE ™ Aluminum Outlet Pole Remove cover from Power and Communication or Communication Only Pole. Cut cover to desired size. Terminate jacks and snap into module frame. Screw module frame and faceplate together. Snap faceplate to channel. Finished product. 3 Installing Standard Screw-On Communication Faceplates into the PAN-POLE ™ Aluminum Outlet Pole Remove cover from Power and Communication or Communication Only Pole. Cut cover to desired size. Snap-On standard faceplate bracket. Terminate jacks, snap jacks into module frame and screw module frame to faceplate bracket. Install faceplate over module frame. Finished product. 4 Installing U.S. Standard Screw-On Communication Faceplates into the PAN-POLE ™ Aluminum Outlet Pole Remove cover from Power and Communication or Communication Only Pole. Cut cover to desired size. Snap-On standard faceplate bracket. Terminate jacks and snap jacks into faceplate. Install faceplate over bracket. Finished product. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I8 PAN-POLE ™ OPEN OFFICE SYSTEM Fill Capacities for PAN-POLE ™ Aluminum Outlet Poles Use the wirefill configurations below along with the wirefill information contained on the next two pages as a guide in selecting the proper size raceway. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. 1a 1b 2a 2b A = .47 in² A = 2.00 in² A = .43 in² A = 1.82 in² Wirefill #1: Data using Snap-On Communication Faceplates (with screw holes to mount a module frame) Wirefill #2: Data using U.S. Standard Screw-On Communication Faceplate and Standard Faceplate Bracket Includes: Snap-On Communication Faceplate (with screw holes to mount a module frame), Standard Communication Module Frame and Communication Modules. Includes: U.S. Standard Screw-On Communication Faceplate, Standard Faceplate Bracket, Sloped Insert, and Communication Modules PAN-POLE Communication Only Pole 4 3 A = 2.70 in² A = 2.46 in² Wirefill #3: Data using Snap-On Communication Faceplates (with screw holes to mount a module frame) Wirefill #4: Data using U.S. Standard Screw-On Communication Faceplate and Standard Faceplate Bracket Includes: Snap-On Communication Faceplate (with scr ew holes to mount a module frame), Standard Communication Module Frame and Communication Modules. Includes: U.S. Standard Screw-On Communication Faceplate, Standard Faceplate Bracket, Sloped Insert, and Com munication Modules For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I9 FILL CAPACITIES PAN-POLE Power and Communication Pole PAN-POLE ™ OPEN OFFICE SYSTEM Fill Capacities for PAN-POLE ™ Aluminum Outlet Poles This information is to be used as a guide in selecting the proper configuration. The maximum amounts may var y according to the wire installation methods, straightness of wires, etc. FILL CAPACITIES SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes ·Electrical MAX=60% wirefill—the maximum cable quantity based on minimal cable interweaving and ideal packing factors (Electrical fill capacity based on UL temperature rise testing) Fill Capacity Table for: ·Voice Grade 24 AWG UTP ·Data Grade 24 AWG UTP Electrical Cables Voice Grade Cables Data Grade Cables AWG 12 24 AWG UTP CM/CMR 2 pr 3 pr 4 pr D IA.= 0.120 DIA.= 0.150 DIA.= 0.190 24 AWG UTP CM 25 pr Cat. 5 4 pr D IA.=0.422 DIA.=0.217 Pole Channel Configurations 0.122 MAX FILL SPEC MAX FILL SPEC MAX 1a PAN-POLE Power & Co mmun icatio ns Pole 11 ** ** ** 1b PAN-POLE Power & Co mmun icatio ns Pole ** 70 106 2a PAN-POLE Power & Commu nications Pole 11 ** ** 2b PAN-POLE Power & Commu nications Pole 3 4 PAN-POLE Co mmunicatio ns Only Po le ** ** ** 64 PAN-POLE Co mmunicatio ns Only Po le FILL SPEC MAX FILL SPEC MAX ** ** SPEC ** FILL MAX ** ** ** ** 45 67 200 42 5 8 21 32 ** ** ** ** ** ** ** ** 96 41 61 25 38 5 7 19 29 95 142 60 91 37 56 7 11 29 43 87 130 55 83 34 51 7 10 26 39 NOTE: See page xiv-xv for further explanation of w irefill data. ** Not power configuration Fill Capacity Table for: ·Data Grade 22 AWG UTP ·Data Grade 24, 22 AWG STP · 1A STP Data Grade Cables 24 AWG STP CM Pole Channel Configurations 1a 1b 2a 2b 3 4 PAN-POLE Power & Comm unication s Pole PAN-POLE Power & Comm unication s Pole PAN-POLE Po wer & Comm unication s Pole PAN-POLE Po wer & Comm unication s Pole PAN-POLE Com munication s Only Po le PAN-POLE Com munication s Only Po le 22 AWG U TP CM 22 AWG STP CM 25 pr 4 pr 25 pr 4 pr 25 pr 4 pr DIA.=0.512 FILL MAX SPEC DIA.=0.250 FILL SPEC MAX D IA.= 0.544 FILL SPEC MAX DIA.= 0.234 F ILL SPEC MAX D IA.=0.635 FILL SPEC MAX DIA.=0.286 FILL SPEC MAX 1A 22 AWG STP CM DIA.=0.430 FILL SPEC MAX ** ** ** ** ** ** ** ** ** ** ** ** ** ** 3 5 16 24 3 5 18 27 2 3 12 18 5 8 ** ** ** ** ** ** ** ** ** ** ** ** ** ** 3 5 14 22 3 4 25 37 2 3 11 16 5 7 5 7 21 32 4 6 22 34 3 5 16 25 7 11 4 7 20 30 4 6 22 34 3 4 15 22 6 10 NOTE: See page xiv-xv for further explanation of wirefill data. ** Not power configuration For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I10 PAN-POLE ™ OPEN OFFICE SYSTEM Fill Capacities for PAN-POLE ™ Aluminum Outlet Pole This information is to be used as a guide in selecting the proper configuration. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. SPEC=40% wirefill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on minimal cable interweaving and ideal packing factors (Electr ical fill capacity based on UL temperature r ise testing) Coax Cables Pole Channel Configurations RG6/u DIA.=0.270 FILL MAX SPEC 1a PAN-POLE Power & Commun ication Pole ** ** 1b PAN-POLE Power & Commun ication Pole 13 20 2a PAN-POLE Power & Commun ication Pole ** ** 2b PAN-POLE Power & Commun ication Pole 12 19 3 PAN-POLE C ommun ication On ly Pole 18 4 PAN-POLE C ommun ication On ly Pole 17 RG 11/u DIA.=0.405 FILL SPEC MAX ** RG58/u DIA.=0.193 FILL SPEC MAX RG 59/u DIA.=0.242 F ILL SPEC MAX ** ** ** ** 6 9 27 40 17 ** ** ** ** ** 5 8 24 37 15 28 8 12 36 55 25 7 11 33 50 ** R G62A/u D IA.=0.242 FILL SPEC MAX ** ** 25 17 25 ** ** ** 23 15 23 23 35 23 35 21 32 21 32 NOT E: See page xiv-xv for further explanation of wirefill data. ** Not power configuration Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Signal Cables Fiber Optic Cables (62.5/125mm) Pole Channel Configurations 2 Stra nd D IA.=0.175 FILL MAX SPEC 4 Strand DIA.=0.175 FILL SPEC MAX 1a PAN-POLE Power & Co mmun ication Po le ** ** ** 1b PAN-POLE Power & Co mmun ication Po le 33 49 33 2a PAN-POLE Power & Co mmun ication Po le ** ** ** 2b PAN-POLE Power & Co mmun ication Po le 30 45 30 3 PAN-POLE Commu nication Only Pole 44 67 4 PAN-POLE Commu nication Only Pole 40 61 ** 6 Strand DIA.=0.210 FILL SPEC MAX ** ** 49 23 34 ** ** ** 45 20 31 44 67 31 46 40 61 28 42 NOTE: See pag e xiv-xv for further explanation of wirefill data. ** Not power configuration For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) I11 FILL CAPACITIES Fill Capacity Table for: ·Coax Cables J Telecom m unicati on Equipm ent Room Products FIBER-DUCT ™ ROUTING SYSTEM FIBER-DUCT ™ Routing System NEC Compliant/UL Listed The FIBER-DUCT Routing System provides a complete solution for routing and protecting your fiber optic cables. This system can also be used for Category 5, UTP, ScTP, and Coax cabling applications as well. The fittings are designed to maintain a minimum 2" cable bend radius which protects against signal loss due to excessive bending of cables. A full selection of fittings is available to speed the installation. Additional features include: UL Listed for general use • UL94V-0 Flammability rating on all PVC fittings and PVC duct • Snap on non-slip covers • Two sizes: 2" X 2" and 4" X 4" • Minimum 2" bend radius fittings • Available in Orange, Light Gray, Black and Yellow (Duct—PVC; Fittings—ABS material) • Available in clear (Polycarbonate material) • Manufactured in an ISO 9001 registered facility I Excellent for use in: • • • • • Telecommunications Closets Central Offices Equipment rooms Entrance facilities Appropriate floor and ceiling spaces Panduit FIBER-DUCT ™ Routing System provides the following key benefits: Compliant with NEC Articles 770 & 800 • Protects against signal loss due to excessive bending • Easy and secure installation—completely enclosed to protect cables • Allows for distribution of large amounts of fiber cable • Identifies Fiber Optic Cable (Orange = Multi-mode; Yellow = Single-Mode) • Provides a totally integrated cabling solution • ISO 9001 assures highest quality and reliability For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J1 FIBER-DUCT ™ ROUTING SYSTEM Table of Contents Page FIBER-DUCT ™ Routing System Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J3-J4 Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J4-J5 PANDUCT ® Types E and S Fiber Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . J3 Fill Capacity Information . . . . . . . . . . . . . . . . . . . . . . . . . . J6 FIBER-DUCT Routing System Applications FIBER-DUCT Routing System can be used with a cable management system when routing fiber optic or category 5 cables to telecommunications racks or enclosures. Both duct and fittings are available in clear for low smoke applications. The clear polycarbonate material allows cable color to show through for easy identification. Both duct and fittings are available in orange (multi-mode) and yellow (single-mode) to clearly identify fiber optic cable. All fittings in this system are designed with a minimum 2" bend r adius to protect fiber optic cables. FIBER-DUCT System includes a complete line of mounting hardware for a variety of applications. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J2 FIBER-DUCT ™ ROUTING SYSTEM PANDUCT ® Solid and Slotted Wall Wiring Duct Nominal Duct Size Duct Part Number Width (in) Height (in) Cover Part Number Color ! Material Duct Cover Std. Std. Ctn. Std. Ctn. Length Qty. Qty. Types S and PS Solid Wall Wiring Duct S2X2OR6NM PS2X2CL6NM C2OR6 2.00 2.00 (50.8mm) (50.8mm) PC2CL6 Orange Clear PVC Polycarbonate 6 ft 6 ft 120 ft 120 ft 120 ft 120 ft S4X4OR6NM PS4X4CL6NM C4OR6 4.00 4.00 (101.6mm) (101.6mm) PC4CL6 Orange Clear PVC Polycarbonate 6 ft 6 ft 120 ft 120 ft 120 ft 120 ft NOTE: Available w ith mounting holes. To order delete NM from the Part Number. Types E and PE Slotted Wall Wiring Duct E2X2OR6 PE2X2CL6 C2OR6 2.00 2.00 (50.8mm) (50.8mm) PC2CL6 Orange Clear PVC Polycarbonate 6 ft 6 ft 120 ft 120 ft 120 ft 120 ft E4X4OR6 PE4X4CL6 C4OR6 4.00 4.00 (101.6mm) (101.6mm) PC4CL6 Orange Clear PVC Polycarbonate 6 ft 6 ft 120 ft 120 ft 120 ft 120 ft NOTE: Available without mounting holes. To order add NM to the end of the Part Number. ! PVC material parts listed in Orange (OR) color. To order other colors in PVC material substitute Yellow (YL), BL (Black), and Light Gray (LG). Contact Factory for details. ORDERING INFORMATION: Order number of feet required, in multiples of Standard Length Increment. FIBER-DUCT ™ System Fittings FCF2X2 FCF4X4 FEC2X2 FEC4X4 FFWC2X2 FFWC4X4 FIVRA2X2 FIVRA4X4 FOVRA2X2 FOVRA4X4 FIV452X2 FIV454X4 FOV452X2 FOV454X4 Par t Number FCF2X2OR PFCF2X2CL FCF4X4OR PFCF4X4CL FEC2X2OR PFEC2X2CL FEC4X4OR PFEC4X4CL FFWC2X2OR PFFWC2X2CL FFWC4X4OR PFFWC4X4CL FIVRA2X2OR PFIVRA2X2CL FIVRA4X4OR PFIVRA4X4CL FOVRA2X2OR PFOVRA2X2CL FOVRA4X4OR PFOVRA4X4CL FIV452X2OR PFIV452X2CL FIV454X4OR PFIV454X4CL FOV452X2OR PFOV452X2CL FOV454X4OR PFOV454X4CL Description Material Color ! Std. Pkg. Qty. Coupler Fitting — 2 x 2 Size Used to join two sections of duct together Coupler Fitting – 4 x 4 Size Used to join two sections of duct together End Cap Fitting — 2 x 2 Size Closes the end of the duct End Cap Fitting — 4 x 4 Size Closes the end of the duct Four Way Cross Fitting — 2 x 2 Size Used to join duct at four way cross intersections Four Way Cross Fitting — 4 x 4 Size Used to join duct at four way cross intersections Inside Vertical Right Angle Fitting — 2 x 2 Size Used to join duct at 90° inside corners Inside Vertical Right Angle Fitting — 4 x 4 Size Used to join duct at 90° inside corners Outside Vertical Right Angle Fitting — 2 x 2 Size Used to join duct at 90° outside corners Outside Vertical Right Angle Fitting — 4 x 4 Size Used to join duct at 90° outside corners Inside Vertical 45° Fitting — 2 x 2 Size Used to join duct at 45° inside corners Inside Vertical 45° Fitting — 4 x 4 Size Used to join duct at 45° inside corners Outside Vertical 45° Fitting — 2 x 2 Size Used to join duct at 45° outside corners Outside Vertical 45° Fitting — 4 x 4 Size Used to join duct at 45° outside corners ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate ABS Polycarbonate Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear Orange Clear 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. pc. Std. Ctn. Qty. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. pcs. ! ABS material parts listed in Orange (OR) color. To order other colors in ABS material substitute Yellow (YL), BL (Black), and Light Gray (LG). Contact Factory for details. ORDERING INF ORMAT ION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J3 FIBER-DUCT ™ ROUTING SYSTEM FIBER-DUCT ™ System Fittings (cont.) Std. Pkg. Qty. FVT2X2 FVT4X4 FRA2X2 FRA4X4 FT2X2 FT4X4 FRF42 Std. Ctn. Qty. Description Material Color! ! Par t Number FVT2X2OR Vertical Tee Fitting — 2 x 2 Size ABS Orange 1 pc. 5 pcs. PFVT2X2CL Used to join vertical and horizontal sections of Polycarbonate Clear 1 pc. 5 pcs. duct FVT4X4OR Vertical Tee Fitting — 4 x 4 Size ABS Orange 1 pc. 5 pcs. PFVT4X4CL Used to join vertical and horizontal sections of Polycarbonate Clear 1 pc. 5 pcs. duct FRA2X2OR Right Angle Fitting — 2 x 2 Size ABS Orange 1 pc. 5 pcs. PFRA2X2CL Used to join duct at 90° flat junctions Polycarbonate Clear 1 pc. 5 pcs. FRA4X4OR Right Angle Fitting — 4 x 4 Size ABS Orange 1 pc. 5 pcs. PFRA4X4CL Used to join duct at 90° flat junctions Polycarbonate Clear 1 pc. 5 pcs. FT2X2OR Tee Fitting — 2 x 2 Size ABS Orange 1 pc. 5 pcs. PFT2X2CL Used to join duct at tee intersections Polycarbonate Clear 1 pc. 5 pcs. FT4X4OR Tee Fitting — 4 x 4 size ABS Orange 1 pc. 5 pcs. PFT4X4CL Used to join duct at tee intersections Polycarbonate Clear 1 pc. 5 pcs. FRF42OR Reduces 4 x 4 size duct to 2 x 2 size. ABS Orange 1 pc. 5 pcs. PFRF42CL Polycarbonate Clear 1 pc. 5 pcs. ! ABS material parts listed in Orange (OR) color. To order other colors in ABS material substitute Yellow (YL), BL (Black), and Light Gray (LG). Contact Factory for details. ORD ERING INFORMAT ION: Order number of pieces required, in multiples of Standard Package. FIBER-DUCT ™ Innerduct Transition Fittings Part Number Description Material Std. Pkg. Qty. Std. Ctn. Qty. Metal** 1 pc. 10 pcs. Innerduct Transition Fitting – 2 x 2 Size FITF2X2 FITF2X2M FITF4X4AM FITF4X4BM Attaches to the end of PANDUCT ® Type E and Type S Duct. It can also be attached anywhere along the side walls of the duct provided the duct fingers or side walls are removed. FIBER-DUCT ™ Innerduct Transition Fitting – 4 x 4 Size FITF4X4A Transition from 4 x 4 duct to 1-2 pcs. 1" innerduct. Metal** 1 pc. 10 pcs. FITF4X4B Transition from 4 x 4 duct to 1-2 pcs. 1 1/4" innerduct. Metal** 1 pc. 10 pcs. ** Commercial grade cold rolled steel with zinc chromate finish. OR DERING INFORMAT ION: Order number of pieces required, in multiples of Standard Package. Mounting Brackets Part Number FTRB12 FTRBE12 FTRBE58 Std. Ctn. Qty. Bracket attaches to UNISTRUT ® Metal Framing. Accepts 1/2" threaded rod (not included). Contains bracket and hardware for attaching to metal framing. 1 pc. 10 pcs. FTRBE12 Bracket attaches to existing 1/2" threaded rod (not included). Contains bracket and hardware for attaching to threaded rods. Bracket attaches to existing 5/8" threaded rod (not included). Contains bracket and hardware for attaching to threaded rods. Bracket attaches to new 1/2" threaded rod (not included). Contains bracket and hardware for attaching to threaded rods. Bracket attaches to new 5/8" threaded rod (not included). Contains bracket and hardware for attaching to threaded rods. Bracket attaches to 3/8" X 1-1/2" or 3/8" X 2" ladder rack rails. Contains hardware for attaching bracket to ladder rack. Also contains hardware for attaching duct/fittings to bracket. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. FTRBN12 FTRBN58 FLRB Description Std. Pkg. Qty. FTRB12 FTRBE58 FTRBN12 FTRBN58 Provides transition from 2 x 2 duct to 3/4" to 1" innerduct. FLRB UNIST RUT ® is a registered trademark of UNIST RUT Corporation ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J4 FIBER-DUCT ™ ROUTING SYSTEM FIBER-DUCT ™ Mounting Brackets (cont.) Par t Num ber FZBA1.5X4 FZBA1.5X4 FLB12X15 FLB12X15 FLB12X20 FLB58X15 FLB58X20 FLB12X20 FLB58X15 FLB58X20 FUSB FLB FUSB FLB FMRB FMRB Std. Pkg. Qty. Description Aluminum bracket used to offset duct from mounting surface, adjustable from 1½" to 4". Bracket attaches to 1-1/2" ladder rack rail. Bracket accepts 1/2" threaded rod (not included). Contains bracket and hardware for attaching bracket to ladder rack. Bracket attaches to 2" ladder rack rail. Bracket accepts 1/2" threaded rod (not included). Contains bracket and hardware for attaching bracket to ladder rack. Bracket attaches to 1-1/2" ladder rack rail. Bracket accepts 5/8" threaded rod (not included). Contains bracket and hardware for attaching bracket to ladder rack. Bracket attaches to 2" ladder rack rail. Bracket accepts 5/8" threaded rod (not included). Contains bracket and hardware for attaching bracket to ladder rack. Bracket attaches to under-floor support pedestal (not included). Contains bracket and hardware for attaching bracket to pedestal. Also contains hardware for attaching duct/fittings to “L” Bracket. “L” Bracket attaches to walls. User supplies appropriate mounting hardware for attaching “L” Bracket to walls. Contains bracket and hardware for attaching duct/fittings to “L” Bracket. “L” Bracket attaches to top rail of rack for added support. Contains bracket and hardware for attaching “L” Bracket to rack and bracket to duct. Std. Ctn. Qty. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. 1 pc. 10 pcs. ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. FIBER-DUCT ™ Accessories Part Number NR2WH-L NR4BL-L Std. Pkg. Qty. Description Std. Ctn. Qty. Optional snap rivet fastens duct and fittings together for added 50 pcs. strength and rigidity. Fastener mounts flush to duct surfaces. 2" X 2" rivet white color. Optional snap rivet fastens duct and fitting together for added 50 pcs. strength and rigidity. Fastener mounts flush to duct surfaces. 4" X 4" rivet black color. 500 pcs. 500 pcs. OR DERING INFORMAT ION: Order number of pieces required, in multiples of Standard Package. Fiber Optic Adhesive Markers Part Number Legend Par t Number Legend Marker Size W XL In. (mm) Markers Per Card Std. Pkg. Qty. Adhesive Marker Cards • Durable markers available in pressure sensitive card • Legend: Black • Background: Orange PCV-FOA Fiber Optic PCV-FOCA Fiber Optic Cable PCV-FOB Fiber Optic PCV-FOCB Fiber Optic Cable PCV-FOC Fiber Optic PCV-FOCC Fiber Optic Cable 9.00 X 2.25 (228.6 X 57.2) 4.50 X 1.19 (114.3 X 28.6) 2.25 X 0.50 (57.1 X 12.7) 1 4 5 Cards 18 ORDERING INF ORMATION: Order number of pieces required, in multiples of Standard Package. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J5 FIBER-DUCT ™ ROUTING SYSTEM B Fill Capacities for PANDUCT ® Type E or Type S FILL CAPACITIES This information is to be used as a guide in selecting the proper size duct. The maximum amounts may vary according to the wire installation methods, straightness of wires, etc. SPEC=40% wir efill—the recommended design in cable capacity. Leaves room for future moves, adds and changes MAX=60% wirefill—the maximum cable quantity based on cable interweaving and packing factors or UL temperature rise test for electrical 2.25" 2.10" A=4.0in 4.25" 2 A=16.0in 2 4.10" E4X4 S4X4 E2X2 S2X2 Fill Capacity Table for: ·Fiber Optic Cable (62.5/125mm) ·Data Grade 24 AWG UTP Fiber Optic Cables (62.5/125mm) Duct Type Size Data Grade Cables 2 Strand 4 Strand 6 Strand 12 Strand 24 Strand 36 Strand 72 Strand DIA.=0.24 DIA.=0.26 DIA.=0.27 DIA.=0.34 DIA.=0.55 DIA.=0.67 DIA.=0.89 24 AWG UTP CM Cat.5 4 pr. 25 pr. DIA=0.422 DIA=0.217 FILL FILL FILL FILL FILL FILL FILL FILL FILL SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX SPEC MAX PANDUCT Type E or S 2"X2" PANDUCT Type E or S 4"X4" 142 35 53 30 45 28 42 18 26 7 10 5 7 3 4 11 17 43 65 212 121 181 112 168 71 106 27 40 18 27 10 15 46 69 173 260 NOTE: See pag e xiv- xv for further explanation of the wirefill data. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) J6 J COMPLETE ROUTING SOLUTIONS Table of Contents Page New TIA/EIA 569-A Requirements for Surface Raceway . . . . . . . . . . xiv-xv New UL-5A Standard Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi CSA 22.2 Standard Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii NEC Article 352B Standard Explanation . . . . . . . . . . . . . . . . . . . . . . . . . xvii Mounting Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Flammability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii Material Physical Properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix Raceway Typical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xx-xxi UL 569-A - Commercial Building Standard for Telecommunications Pathways and Spaces The purpose of this standard is to standardize specific design and construction practices (in support of telecommunications media and equipment) within and between commercial buildings. Standards are given for rooms or areas and pathways into and through which telecommunications equipment and media are installed. The key requirements for surface raceways are as follows: Section 4.7 of 569-A describes perimeter pathways and it is here that surface raceway requirements are found. Surface raceways are horizontal pathways for the installation of media from the telecommunications closet to the work area. Section 4.7 perimeter pathways — Key Points Summary: • Perimeter pathways serve work areas where telecommunication devices can be reached from walls at convenient levels. • Divided or multichannel raceways may include telecommunication and power cabling and outlets as needed. 4.7.1 also states that perimeter pathways shall comply with clause 10.3. 10.3 Horizontal pathway separation from EMI sources states: 1) Co-installation of telecommunications cable and power cable is governed by the applicable electrical code for safety. Article 800-52 of ANSI/NFPA 70 shall be applied, for example: a) separation from power conductors b) separation and barriers within raceway c) separation within outlet boxes or compartments Article 800-52 requires a physical barrier between power and telecommunication cables. (Non-metallic divider walls are suitable physical barriers.) No minimum separation distance is required. 4.7.2.1 Surface raceway - Surface raceway consists of base, cover and related fittings that mount directly on walls at appropriate work levels to provide a continuous perimeter pathway. Telecommunication outlets are located along the raceway and may be moved or added after initial installation if desired. 4.7.2.4 Multi-Channel raceway - Multichannel raceway provides a perimeter pathway for different systems in combination, such as telecommunication and each channel is maintained for each system throughout the building. 4.7.3.2 Pathway Sizing - Currently states that practical raceway capacity for telecommunication cabling ranges from 20-40% depending on cable-bending radius. It further notes that pathway fill is under study. As a participant in that study, Panduit and other surface raceway manufactures have found that fill capacities of surface raceway can be up to 60% when appropriate bend radius is provided. Factors that affect fill capacity are discussed on the following page: For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xiv COMPLETE ROUTING SOLUTIONS UL 569-A - Commercial Building Standard for Telecommunications Pathways and Spaces (cont’d) TIA/EIA 569-A Initially one may think... RACEWAY AREA # of Cables that = fit into the Channel CABLE(S) AREA But in reality this is impossible ..... Why? Consider this... The Pac king Fa ctor • Cables placed into the channel leave some unusable area depending on the diameter of the cable and shape of the raceway channel. Commonly referred to as the “packing factor”. • Termination devices placed within the surface raceway also reduce the available internal area within the channel.† • Add in other real world considerations, such as, interweaved/crossed cables and the usable area becomes even less. • If the cables being routed require a 1” bend radius and the fittings have a smaller radius even less internal area is available for cables. 4.7.3.2 Pathway Sizing (cont’d) Anticipated changes to the existing fill capacity suggestions from 569-A have led Panduit to provide the following wirefill quantities for specifying PAN-WAY™ Surface Raceway Systems: SPEC : The cable quantity to be used when specifying Raceway Internal Area a new raceway. This quantity leaves room for adding SPEC= X 40% Cable Area cabling in the future. MAX= Raceway Internal Area Cable Area X 60% MAX : The maximum cable quantity that will fit into the raceway (considering factors previously mentioned).^ ^If the bend radius of the cable can not be realized with the fittings of the system this value cannot be attained. Example: Find the SPEC and MAX cable quantities for LDP3 (internal area= .21in²) when routing Category 5 UTP cabling (dia= .217") 1. Determ ine Cable Area: CABLE AREA =π r² =(3.14)(.217/2)² =.03695in² 2. Determine SPEC Quantity: SPEC =.21in²/.03695in² X .40 =2.27 or =2 Cables 3. Determine MAX Quantity: MAX =.21in²/.03695in² X .60 =3.40 or =3 C ab les Note 1: Per TIA/EIA TR41.8.3 Committee investigations new installations of perimeter raceway systems should be sized using a cable fill based on 40% of the raceway cross-sectional area. A maximum cable fill based on 60% of the raceway cross-sectional area may be attained if the pathway provides the appropriate bend radius for the radius of the cable being routed. Note 2 : Power cabling fill capacities of non-metallic raceways are determined by the UL-5A Temperature Test (See UL-5A Brief Explanation on following page.) The MAX value listed in wirefill capacity tables indicates the maximum number of power conductors that can be placed into the raceway channel or indicated channel area. 4.7.3.3 Physical Limitations - Use surface raceway in dry locations 4.7.3.4 Perimeter raceways should follow the bend radius requirements of the cable. (1” for category 5 UTP) †Panduit wirefills reference only the usable area for each configur ation of each system . NOTE: The information provided above is intended for use only as a guideline. Please refer to the specified document for detailed test descriptions or standards information. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xv COMPLETE ROUTING SOLUTIONS UL-5A Brief Explanation (Standard for Safety of Non-metallic Surface Raceways and Fittings) The UL Listing mark found on Panduit non-metallic surface raceway systems assures that the raceway components have been evaluated in accordance with the UL-5A standard. Our systems meet or exceed the requirements of ALL (not just some) of the tests outlined within UL-5A. This assures the end user of a quality product which will perform in a safe manner when installed as recommended. NOTE: The information provided above is intended for use only as a guideline. Please refer to the specified document for detaile d test descriptions or standards information. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xvi UL-5A/CSA 22.2/NEC352B A product bearing UL-5A listing complies with tests that include the following: • Utilizes a UL RECOGNIZED material which meets specific UL property requirements. (such as volume resistivity, hot wire ignition, high current ARC ignition, dielectric strength and heat deflection temperature.) • FLAMMABILITY: The system material has a flammability rating of 94V-0. The finished part has a flammability rating of 94-5VA. Both the raceway and associated fittings will not ignite combustible materials in its vicinity or support a flame longer than 60 seconds following the final test flame application. • LOW TEMPERATURE HANDLING AT -32°C: This test assures that the raceway integrity will remain intact under typical conditions encountered during shipment and handling in a hostile subzero temperature. • COLD TEMPERATURE IMPACT AT 0°C: A 1.18 lb. steel sphere is dropped from a height of 51inches to produce an impact of 5 ft./lbs. This test simulates the impact resistance of the product when subjected to a cold temperature extreme following installation, such as cold storage or an area without heat. • CRUSHING: Both the raceway and fittings are subjected to a compressive load of 300 lbs. which is maintained for one minute. This load is twice the average weight of an average person. Following the removal of the load, both the raceway and fittings remain intact and show no signs of permanent deformation. • TEST FOR MOLD STRESS: During the cooling process stresses may be frozen in the raceway or fitting. This test conditions the product in an air circulating oven for seven (7) hours at the maximum intended useful temperature of the system. After cooling to room temperature the raceway system with cover remains intact and secure. • TEMPERATURE TEST: The raceway undergoes a four (4) hour test to determine the safe number of ELECTRICAL conductors with which to operate the system. This assures the end user that the POWER conductor and raceway will not exceed their respective temperature rating during their intended operation. • TRIAL INSTALLATION: This is conducted to verify that the recommended installation instructions and MOUNTING HARDWARE are effective and that the system maintains a complete and safe enclosure of conductors. • RECEPTACLE SECURENESS: Assures that a receptacle shall remain secure in the raceway when a power cord attachment plug is inserted and a 25 lb. weight is applied for 60 seconds. This test is conducted with the receptacle positioned horizontally to the ground and then repeated with receptacle face at a 30° angle to the power cord. • SECURITY OF KNOCKOUT AND BREAKAWAY TAB: A knockout or break-away tab shall remain intact following a force application of 10 lbs. for 60 seconds. Following the removal of the tab no sharp edges shall be left which could cause the removal of the conductor insulation. This test assures that the tab can resist an applied force but can be removed easily per recommended instructions. COMPLETE ROUTING SOLUTIONS CSA 22.2 No. 62-93 Brief Explanation UL-5A/CSA22.2/NEC352B (Surface Raceway Systems) The CSA (Canadian Standards Association) Listing mark found on Panduit non-metallic surface raceway systems assures that the raceway components have been evaluated in accordance with the CSA 22.2 No. 62-93 standard. Our systems meet or exceed the requirements of ALL (not just some) of the tests outlined within CSA 22.2. This assures the end user of a quality product which will perform in a safe manner when installed as recommended. These tests parallel the tests outlined on the previous page for UL listing and are not listed here (consult CSA22.2 No. 62-93 for specific test information.) NEC Article 352B Brief Explanation (Non-Metallic Surface Raceways) Non-metallic surface raceways are addressed under section 352B of the National Electric Code, please reference this section of the NEC for specific information regarding non-metallic surface raceway. 352B applies to a type of non-metallic surface raceway and fittings of suitable nonmetallic material that is resistant to moisture and chemical atmospheres. It shall also be flame retardant, resistant to impact and crushing, resistant to distor tion from heat under conditions likely to be encountered in service, and resistant to low-temperature effects. Section 352B includes the following: 352-22. Use The use of non-metallic surface raceways shall be permitted in dry locations. They shall not be used where concealed 352-26. Combination Raceways. Where combination non-metallic surface raceways are used both for signaling and for lighting and power circuits, the different systems shall be run in separate compartments, identified by printed legend or by sharply contrasting colors of the interior finish, and the same relative position of compartments shall be maintained throughout the premises. 352-27. General. Non-metallic surface raceways shall be of such construction as will distinguish them from other raceways. Non-metallic surface raceways and their elbows, couplings, and similar fittings shall be so designed that the sections can be mechanically coupled together and installed without subjecting the wires to abrasion. 352-28. Extension Through Walls and Floors. Non-metallic surface raceways shall be permitted to pass transversely through dry walls, dry partitions, and dry floors if the length passing through is unbroken. Access to the conductors shall be maintained on both sides of the wall, partition, or floor. 352-29. Splices and Taps. Splices and taps shall be permitted in non-metallic surface raceways having a removable cover that is accessible after installation. The conductors, including splices and taps, shall not fill the raceway to more than 75 percent of its area at that point. Splices and taps in non-metallic surface raceways without removable covers shall be made only in junction boxes. All splices and taps shall be made by approved methods. NOTE: The information provided above is intended for use only as a guideline. Please refer to the specified document for detaile d test descriptions or standards information. For Technical Assistance, call: 888-506-5400, Ext. 8287 (outside the U.S., see inside back cover for International Directory) xvii COMPLETE ROUTING SOLUTIONS Mounting Guidelines Low Voltage (Data) Installations Data only (low voltage
PFBC36EI18 价格&库存

很抱歉,暂时无法提供与“PFBC36EI18”相匹配的价格&库存,您可以联系我们找货

免费人工找货