ELECTRICAL SOLUTIONS
A.
System
Overview
PAN-WAY ® METAL RACEWAY
Pan-Way ® Metal Raceway is a series of single and multi-channel solutions for routing, protecting,
concealing and terminating power wire and high performance copper, voice, video or fiber optic cable.
Panduit metal raceway is designed with labor saving features to increase productivity and lower
installed costs, while incorporating benefits of increased safety and cable protection. Pan-Way ® Metal
Raceway is an innovative routing solution that offers superior benefits over competitive systems:
PMR5 and PMR7 Single Channel Metal Raceway
• Raceway system features a patent pending bonding
design that provides full continuity of the ground
path between fittings and channel, for increased
electrical safety
• System components incorporate an innovative
snap-mount assembly method for fast installations,
resulting in measurable contractor labor savings
• Fittings and mounts can be attached using various
types and sizes of fasteners, eliminating the
requirements of using only flat head style screws
• One-piece channel construction eliminates the
problem of channel separation, associated with
competitive two-piece designs, saving
installation time
PMR40 Multi-Channel Metal Raceway
• Raceway accepts standard double gang faceplates
for increased termination options and reduced
number of components
• System includes optional faceplates and fittings to
support high performance Category 6A copper and
fiber optic cabling terminations
• Full capacity 2 inch bend radius fittings provide
necessary cable protection without restricting
channel capacity
Pan-Way ® Metal Raceway systems include a complete assortment of fittings, junction boxes,
faceplates and accessories.They are available in white and almond color to match any decor and
most popular electrical outlets. Systems are optimized for use with Panduit® Mini-Com ® Modules
for complete connectivity possibilities.
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
C2.1
ELECTRICAL SOLUTIONS
A.
System
Overview
PMR40 Raceway Roadmap
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
P
C1.
Wiring
Duct
C2.
Surface
Raceway
See exploded
view 1 pg. C2.4
1
A
N
B
F
C
C3.
Abrasion
Protection
C4.
Cable
Management
Q
J
D
E
G
K
H
L
O
See exploded
view 2 pg. C2.4
M
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.2
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
1
1
1
PMR40** – PMR40 Metal
Raceway (page C2.5)
PMR40C** – PMR40 Cover
(page C2.5)
PMR40DW* – PMR40 Divider
Wall (page C2.5)
G
PMR40FH4** – Horizontal Sloped
Communication Faceplate
(page C2.6)
B1.
Cable Ties
B2.
Cable
Accessories
H
PMR40DP50** – PMR40 50/50
Data Plate (page C2.6)
J
MP2GR** – Double Gang
Rectangular Faceplate
(page C2.17)
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
1
PMR40DC-X – PMR40 Divider Clip
(page C2.5)
A
PMR40EC** – End Cap
(page C2.6)
K
ERU20** – 20 A Specification
Grade Rectangular Outlet
(page C2.61)
L
CFG4 – Mini-Com® Frame
(see SA-NCCB51)
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
B
C
D
PMR40T** – Tee Fitting
(page C2.6)
M
PMR40TD50 – Tee Divider Insert
(page C2.6 )
N
PMR40BF** – Backfeed Fitting
(page C2.6)
O
PMR40DB50 – Device Bracket
(page C2.6)
PMR40IC** – Inside Corner
(page C2.6)
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
PMR40RA** – Right Angle
(page C2.5)
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E
F
PMR40SOC** – Outside Corner
(no bend radius) (page C2.6)
PMR40C**7.75 – Pre-Cut Cover
for mounting devices on
12” centers (page C2.5)
P
Q
PMR40EE** – Entrance End
(page C2.6)
PMR40SC**-X – Seam Clip
(page C2.5)
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
C2.3
ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
PMR40 Configurations
Exploded View 1
Components Required
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
See page
A.
PMR40FH4 = Horizontal sloped
communication faceplate.
C2.6
B.
PMR40DP50** = PMR40 50/50 data plate
and offset divider wall.
C2.6
C.
Mini-Com ® Modules.
—
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C
C4.
Cable
Management
D1.
Terminals
B
Exploded View 2
A
Components Required
D2.
Power
Connectors
D3.
Grounding
Connectors
See page
A.
MP2GR** = Double gang rectangular faceplate.
C2.17
B.
ERU20** = 20 V specification grade rectangular outlet.
C2.61
C.
CFG4 = Mini-Com Frame.
D.
Mini-Com Modules.
E.
PMR40DB50 = Device bracket.
—
®
®
—
C2.6
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
D
C
E
B
E5.
Lockout/
Tagout
& Safety
Solutions
A
F.
Index
C2.4
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® PMR40 Metal Raceway System
• c-UL-us listed and rated to 600 V; meets UL 5 and
CSA22.2 No. 62-93 safety standards
• Raceway accepts standard double gang faceplates for increased
termination options and reduced number of components
• System includes optional faceplates and fittings to support high
performance Category 6A copper and fiber optic
cabling terminations
• Full capacity 2 inch bend radius fittings provide
necessary cable protection without restricting channel capacity
• Supplied with pre-punched mounting holes
B1.
Cable Ties
1.61"
B2.
Cable
Accessories
5.04"
PMR40
Internal Area = 7.45 Sq. In.
Part Number
Part Description
Raceway
Size
Std.
Length Pkg.
Color‡
Ft.
Qty.
B3.
Stainless
Steel Ties
PMR40 Metal Raceway Base
5.04" x 1.61"
(128.0mm x
40.9mm)
White
10
10
C1.
Wiring
Duct
—
White
5
5
C2.
Surface
Raceway
7.75" pre-cut cover. To be used with
PMR40 raceway for mounting devices on
12" centers.
—
White
—
1
PMR40CWH13.75 13.75" pre-cut cover. To be used with
PMR40 raceway for mounting devices on
18" centers.
—
White
—
1
PMR40CWH19.75 19.75" pre-cut cover. To be used with
PMR40 raceway for mounting devices on
24" centers.
—
White
—
1
C4.
Cable
Management
PMR40CWH31.75 31.75" pre-cut cover. To be used with
PMR40 raceway for mounting devices on
36" centers.
—
White
—
1
D1.
Terminals
—
Gray
5
5
D2.
Power
Connectors
PMR40BWH10
PMR40B
PMR40C
PMR40 raceway base available in 10'
lengths. Supplied with pre-punched
mounting holes.
PMR40 Metal Raceway Cover
PMR40CWH5
PMR40 raceway cover available in
5' lengths.
PMR40 Metal Raceway Pre-cut Covers
PMR40CWH7.75
PMR40C***
PMR40C***
PMR40C***
PMR40C***
PMR40 Metal Raceway Divider Wall
PMR40DW5
PMR40DW5
PMR40DC
PMR40 divider wall snaps into
PMR40DC-X to create separate
channels. Must use wire retainers to
ensure channel separation per UL/CSA.
Available in 5' lengths.
D3.
Grounding
Connectors
PMR40 Metal Raceway Divider Wall Clip
PMR40DC-X
Divider wall clip. Required for supporting
PMR40DW. 30" spacing recommended
between clips.
C3.
Abrasion
Protection
—
Gray
—
10
E1.
Labeling
Systems
‡For other colors replace WH (White) with AL (Almond). Order number of feet required in multiples of standard
carton quantity. Order raceway base and cover separately.
E2.
Labels
Pan-Way ® PMR40 Metal Raceway Fittings
• PMR40 fittings are designed to exceed the TIA/EIA-568-B and 569-B required minimum bend radius for high
performance copper and fiber optic cabling systems
PMR40SCWH-X
PMR40BC
Std.
Pkg.
Color‡ Qty.
White 10
Std.
Ctn.
Qty.
100
Part Number
PMR40SCWH-X
Part Description
Seam clip. Used to join sections of PMR40 raceway.
PMR40BC
Base coupler. Used to join sections of PMR40 raceway
base.
Gray
10
100
PMR40RAWH
Right angle fitting. Used to join sections of PMR40
raceway at right angles.
White
1
10
PMR40SIC
Inside corner fitting w/out bend radius control. Used to
join sections of PMR40 raceway at inside corners.
Gray
1
10
‡For other colors replace WH (White) with AL (Almond).
PMR40RA
PMR40SIC
Table continues on page C2.6
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.5
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® PMR40 Metal Raceway Fittings (continued)
B1.
Cable Ties
B2.
Cable
Accessories
PMR40IC
PMR40SOC
PMR40OC
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
PMR40E45E
PMR40TD50
PMR40T
PMR40EC
C4.
Cable
Management
PMR40EE
Part Description
Inside corner fitting. Used to join sections of PMR40
raceway at inside corners.
PMR40I45EWH
Internal 45° elbow fitting. Used to join sections of PMR40
raceway at 45° inside corners.
White
1
10
PMR40SOCWH
Outside corner fitting without bend radius control. Used to
join sections of PMR40 raceway at outside corners.
White
1
10
PMR40OCWH
Outside corner fitting. Used to join sections of PMR40
raceway at outside corners.
White
1
10
PMR40E45EWH
External 45° elbow fitting. Used to join sections of PMR40
raceway at 45° outside corners.
White
1
10
PMR40TWH
Tee fitting. Used to join sections of PMR40 raceway at tee
intersections.
White
1
10
PMR40TD50
Tee divider insert for a 50/50 data/power split. Maintains
a 50/50 channel separation for power and data
applications.
Gray
1
10
PMR40ECWH
End cap fitting. Used to terminate or allow entry into
PMR40 raceway. Breakouts for 1/2" conduit.
White
1
10
PMR40EEWH
Entrance end fitting. Breakouts for 3/4", 1", and 1 1/4"
conduit which allows entry from ceiling or wall.
White
1
10
PMR40TRWH
WIREMOLD* to PMR40 transition fitting. In-line transition
fitting from WIREMOLD* 4000 series to PMR40 raceway.
White
1
10
PMR40BFWH
Backfeed fitting. Allows cable entry through the back of
the PMR40 raceway. Two round breakouts for 1/2", 3/4"
and 1" conduit, two round breakouts for 3/4", 1", and 1
1/4" conduit and two 1 11/16" X 2 9/16" rectangular
breakouts.
Panel connector. To connect PMR40 raceway with surface
type panel boxes.
White
1
10
White
1
10
PMR40TR
D1.
Terminals
D2.
Power
Connectors
Part Number
PMR40ICWH
PMR40I45E
B3.
Stainless
Steel Ties
PMR40PCWH
PMR40BF
PMR40PC
PMR40ICC
Internal corner coupling.
Gray
1
10
PMR40WR-X
Wire retainer. Used to hold wires in place during
installation.
Device mounting bracket 50/50 split. Used to mount
NEMA standard single gang electrical outlets and
communication devices with either screw-on or snap-on
single gang faceplates.
Gray
10
100
Gray
1
10
PMR40 data plate for mounting data faceplates
PMR40FH2, PMR40FH4, PMR40KH2 or PMR40KH4
when a 50/50 split channel is used in the PMR40 base.
Includes data plate, 2.50" pre-cut cover, and offset divider
wall.
Snap-on horizontal sloped communication faceplate.
Accepts two Panduit ® Mini-Com ® Modules (not included).
Note: Customer needs to purchase PMR40DP50WH.
White
1
10
White
1
10
Snap-on horizontal sloped communication faceplate.
Accepts four Panduit ® Mini-Com ® Modules (not
included).
Note: Customer needs to purchase PMR40DP50WH.
Snap-on horizontal sloped communication faceplate.
Accepts two Keystone modules (not included).
Note: Customer needs to purchase PMR40DP50WH.
White
1
10
White
1
10
PMR40KH4WH
Snap-on horizontal sloped communication faceplate.
Accepts four Keystone modules (not included).
Note: Customer needs to purchase PMR40DP50WH.
White
1
10
RBFIWH
Rectangular blank faceplate. Snap-in insert for any NEMA
standard rectangular opening in metal raceway
faceplates. Reserves the location for future use.
White
1
10
PMR40DB50
D3.
Grounding
Connectors
PMR40ICC
PMR40WR
PMR40DP50WH
E1.
Labeling
Systems
PMR40DB50
PMR40DP50
PMR40FH2WH
E2.
Labels
PMR40FH4WH
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
PMR40FH2
E5.
Lockout/
Tagout
& Safety
Solutions
RBFIWH
F.
Index
C2.6
PMR40FH4
PMR40KH2WH
PMR40KH2
PMR40KH4
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
White
1
10
‡For other colors replace WH (White) with AL (Almond).
*WIREMOLD is a registered trademark of the Wiremold Co.
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Cable Fill Capacities for PMR40 Metal Raceway
This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according
to the cable installation methods, straightness of cables, etc.
a
a
a
b
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
A = 7.45 in.2
A = 6.18 in.2
A = 2.64 in.2
Cable fill #1: Open channel
without devices
Cable fill #2: Undivided,
wire retainer only
B = 3.04 in.2
Cable fill #3: Divided with
wire retainer
C1.
Wiring
Duct
C2.
Surface
Raceway
a
b
a
A = 4.64 in.2
A = 1.87 in.2
Cable fill #4: Undivided with duplex
receptacle on two sides
a
A = 2.49 in.2
B = 2.84 in.2
Cable fill #5: Divided with duplex
receptacle on (A) side
b
B = 2.21 in.2
C3.
Abrasion
Protection
C4.
Cable
Management
Cable fill #6: Divided with duplex
receptacle on (B) side
D1.
Terminals
MAX for 60% cable fill – Recommended by TIA/EIA-569-B for
unplanned additions.
SPEC = 40% cable fill – Recommended by TIA/EIA-569-B
for design.
MAX for 40% power cable fill – Based on available internal area.
Electrical Cables
Data Grade
Cables
Data Grade
Cables
Audio/Video
14 AWG 12 AWG 10 AWG 24 AWG/UTP CM 24 AWG/UTP CM
Raceway Type
and Configuration
RG6
Fill Area
(in2)
THHN/T90
0.111
1. PMR40 - Undivided
(base and cover)
2. PMR40 - Undivided,
wire retainer only
3a. PMR40 - Divided,
with wire retainer
3b.
4. PMR40 - Undivided
with duplex receptacle
2 sides
PMR40 - Divided
5a. with duplex
receptacle on
5b. (A) side
PMR40 - Divided
6a. with duplex
receptacle on
6b. (B) side
Cat. 6
Cat. 6A
DIA. = 0.250
FILL
SPEC
MAX
40%
60%
DIA. = 0.330
FILL
SPEC
MAX
40%
60%
DIA. = 0.275
FILL
SPEC
MAX
40%
60%
0.164
MAX
40%
0.130
FILL
MAX
40%
7.45
307
224
140
60
91
34
52
50
75
6.18
255
186
117
50
75
28
43
41
62
2.64
109
79
50
21
32
12
18
17
26
3.04
125
91
57
24
37
14
21
20
30
4.64
191
139
87
—
—
—
—
—
—
MAX
40%
1.87
78
57
36
—
—
—
—
—
—
2.84
—
—
—
23
34
13
19
19
28
2.49
—
—
—
20
30
11
17
16
25
2.21
91
66
41
—
—
—
—
—
—
AWG dimensions represent typical outer cable diameter in inches.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.7
ELECTRICAL SOLUTIONS
A.
System
Overview
PMR5/7 Raceway Roadmap
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
F
B
F
A
1
1
2
C1.
Wiring
Duct
C
C
G
P
C2.
Surface
Raceway
J
H
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
Q
M
See exploded
view 2 pg. C2.10
R
M
N
D
J
E
E
O
S
K
L
See exploded
view 1 pg. C2.10
C
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.8
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
1
2
A
B
PMR5** – PMR5 Metal Raceway
(page C2.11)
K
PMR7** – PMR7 Metal Raceway
(page C2.11)
L
PMR7OC** – Outside Corner
Fitting (page C2.12)
M
ERU20** – 20 A Specification
Grade Rectangular Outlet
(page C2.61)
PMR5738A** – Round
Fan/Fixture Box (page C2.16)
H
J
PMR5747-2** – Double Gang
Shallow Outlet Box (page C2.15)
MP1TS** – Single Gang Toggle
Switch Faceplate
(page C2.17 )
MP2GR** – Double Gang
Rectangular Faceplate
(page C2.17)
PMR57EE** – Entrance End Fitting
(page C2.12)
PMR5748** – Single Gang Outlet
Box (page C2.15)
PMR7MS** – Mounting Strap
(page C2.11)
PMR57T** – Tee Fitting
(page C2.12)
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
R
G
PMR7IC** – Inside Corner Fitting
(page C2.12)
PMR5751** – Single Gang
Extension Box (page C2.15)
Q
F
MP1GR** – Single Gang
Rectangular Faceplate
(page C2.17)
PMR57SC-X – Supporting Clip
(page C2.11)
P
E
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
PMR57CB** – Corner Box
(page C2.12)
O
D
B1.
Cable Ties
B2.
Cable
Accessories
N
C
PMR7RA** – Right Angle Fitting
(page C2.12)
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
S
PMR7DA** – Diagonal 45° Angle
Fitting (page C2.12)
PMR5747** – Single Gang
Shallow Outlet Box (page C2.15)
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
C2.9
ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
PMR5/PMR7 Configurations
Exploded View 1
Components Required
B2.
Cable
Accessories
See page
MP2GR = Double gang rectangular faceplate.
C2.17
B.
ERU20 = 20 A Specification rectangular outlet.
C2.61
C.
PMR5747-2 = Double gang deep outlet box.
C2.15
A.
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
C
B
D1.
Terminals
A
D2.
Power
Connectors
Exploded View 2
D3.
Grounding
Connectors
E1.
Labeling
Systems
Components Required
See page
A.
PMR57SC-X = Supporting clip.
C2.11
B.
PMR7*** = PMR7 metal raceway.
C2.11
E2.
Labels
B
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
A
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.10
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® PMR5/PMR7 Metal Raceway System
• c-UL-us listed and rated to 600 V; meets UL 5 and CSA22.2
No. 62-93 safety standards
• Raceway system features a patent pending bonding design that
provides full continuity of the ground path between fittings and
channel, for increased electrical safety
• System components incorporate a unique snap mount assembly
method for faster installation
• Fittings and mounts can be attached using various types and sizes
of fasteners, eliminating the requirements of using only flat head
style screws
• One-piece channel construction eliminates the problem of channel
separation, associated with competitive two-piece designs, saving
installation time
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
Part Number
Part Description
Raceway
Size
Std. Std.
Length Pkg. Ctn.
Color‡
(Ft.) Qty. Qty.
C2.
Surface
Raceway
PMR5 Metal Raceway
PMR5
PMR5WH5
One-piece single channel metal
surface raceway. Available in 5'
lengths.
0.86" x 0.60"
(21.8mm x
15.2mm)
White
5
5
50
PMR5WH10
One-piece single channel metal
surface raceway. Available in 10'
lengths.
0.86" x 0.60"
(21.8mm x
15.2mm)
White
10
10
100
One-piece single channel metal
surface raceway. Available in 5'
lengths.
0.86" x 0.72"
(21.8mm x
18.3mm)
White
One-piece single channel metal
surface raceway. Available in 10'
lengths.
0.86" x 0.72"
(21.8mm x
18.3mm)
White
—
Gray
C4.
Cable
Management
PMR7 Metal Raceway
PMR7WH5
PMR7WH10
PMR7
5
5
50
D1.
Terminals
10
10
100
D2.
Power
Connectors
PMR7 Metal Raceway
PMR57SC-X
Supporting clip used to support
lengths of PMR5 or PMR7
raceway at any desired point.
—
10
100
D3.
Grounding
Connectors
PMR7 Metal Raceway
PMR57JC-X
Joint coupling used to join two
lengths of PMR5 or PMR7
raceway.
—
Gray
—
10
100
E1.
Labeling
Systems
PMR7 Metal Raceway
PMR57SC
PMR57JC
Ground clip used to provide
additional grounding of raceway
or to ground remote installations.
For use with PMR5 or PMR7
raceway.
—
PMR5WPB-X
Bushing used to protect wires
from abrasion. For use with
PMR5 raceway.
—
Gray
—
10
100
PMR7WPB-X
Bushing used to protect wires
from abrasion. For use with
PMR7 raceway.
—
Gray
—
10
100
—
White
—
10
100
—
White
—
10
100
PMR57GC-X
Gray
—
10
100
E2.
Labels
Supporting Clip
PMR57GC
PMR5WPB
PMR7WPB
PMR7 Metal Raceway
PMR5MS
PMR7MS
PMR5MSWH-X Mounting strap for use with PMR5
raceway.
PMR7MSWH-X Mounting strap for use with PMR7
raceway.
C3.
Abrasion
Protection
‡For other colors replace WH (White) with AL (Almond).
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.11
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® PMR5/PMR7 Metal Raceway Fittings
B1.
Cable Ties
B2.
Cable
Accessories
PMR5CC
PMR7CC
PMR5RA
PMR7RA
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
PMR5DA
PMR7DA
PMR5IC
PMR7IC
C2.
Surface
Raceway
C3.
Abrasion
Protection
PMR5OC
PMR7OC
PMR57LTE
C4.
Cable
Management
PMR57RTE
D2.
Power
Connectors
PMR57EE
E1.
Labeling
Systems
PMR57CB
PMR5TR
PMR7TR
E2.
Labels
PMR57EBC
PMR57ECC
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
PMR57JBC50
PMR57JBC75
Part Description
Coupler fitting for use with PMR5 raceway.
PMR7CCWH-X
Coupler fitting for use with PMR7 raceway.
White
10
100
PMR5RAWH
Right angle fitting for use with PMR5 raceway.
White
1
10
PMR7RAWH
Right angle fitting for use with PMR7 raceway.
White
1
10
PMR5DAWH
Diagonal 45° angle fitting for use with PMR5 raceway.
White
1
10
PMR7DAWH
Diagonal 45° angle fitting for use with PMR7 raceway.
White
1
10
PMR5ICWH
Inside corner fitting for use with PMR5 raceway.
White
1
10
PMR7ICWH
Inside corner fitting for use with PMR7 raceway.
White
1
10
PMR5OCWH
Outside corner fitting for use with PMR5 raceway.
White
1
10
PMR7OCWH
Outside corner fitting for use with PMR7 raceway.
White
1
10
PMR57LTEWH
Left twisted elbow for 90° twist with 90° turn. For double
turn at right angles from one surface to another, such as a
flat run on a sidewall to a flat run on a ceiling. For use with
PMR5 and PMR7 raceway.
White
1
10
PMR57RTEWH
Right twisted elbow for 90° twist with 90° turn. For double
turn at right angles from one surface to another, such as a
flat run on a sidewall to a flat run on a ceiling. For use with
PMR5 and PMR7 raceway.
White
1
10
PMR57TWH
Tee fitting for use with PMR5 or PMR7 raceway.
White
1
10
PMR57EEWH
Entrance end fitting. 1/2" conduit breakouts allows entry of
PMR5 or PMR7 raceway from a box, the ceiling, or a wall.
Spring steel bushing included for use when connecting to
a box.
White
1
10
PMR57AOCWH
Adjustable offset allows PMR5 or PMR7 to be mounted
flush to wall when connected to surface type panel boxes.
Adjustable between 5/8" and 1 3/8" from surface to center
of conduit. 1/2" chase nipple and locknut included.
White
1
10
PMR57CBWH
Corner box for connecting PMR5 or PMR7 raceway. Each
leg has 1/2" conduit breakouts and room for splicing.
White
1
10
PMR5TRWH
WIREMOLD* to PMR5 transition fitting. In-line transition
fitting from WIREMOLD* 500 series to PMR5 raceway.
White
1
10
PMR7TRWH
WIREMOLD* to PMR7 Transition fitting. In-line transition
fitting from WIREMOLD* 700 series to PMR7 raceway.
White
1
10
PMR57EBCWH
Elbow box connector used to connect PMR5 or PMR7
raceway to boxes at a right angle. Breakouts for
1/2" conduit.
White
1
10
PMR57ECCWH
Elbow conduit connector used to connect PMR5 or PMR7
raceway to conduit at a right angle. Breakouts for
1/2" conduit.
White
1
10
PMR57JBC50-X Junction box connector used to connect PMR5 or PMR7
raceway to boxes with 1/2" conduit breakout.
White
10
100
PMR57JBC75-X Junction box connector used to connect PMR5 or PMR7
raceway to boxes with 3/4" conduit breakout.
White
10
100
PMR57AOC
D3.
Grounding
Connectors
PMR57CC50
PMR57CC75
Std.
Ctn.
Qty.
100
Part Number
PMR5CCWH-X
PMR57T
D1.
Terminals
Std.
Pkg.
Color‡ Qty.
White 10
PMR57CC50-X
Conduit connector used to connect PMR5 or PMR7
raceway to 1/2" conduit.
White
10
100
PMR57CC75-X
Conduit connector used to connect PMR5 or PMR7
raceway to 3/4" conduit.
White
10
100
‡For other colors replace WH (White) with AL (Almond).
*WIREMOLD is a registered trademark of the Wiremold Co.
F.
Index
C2.12
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
PMR5 and PMR7 Raceway Accessories
PMR57MRT
Std. Std.
Pkg. Ctn.
Color Qty. Qty.
Black
1
10
Part Number
PMR57MRT
Part Description
Metal raceway tool. To aid in the installation and removal of
PMR5 and PMR7 metal raceway base sections.
PMRTUPAL
Touch-up paint pen. Used to repair areas of metal raceway
where paint has been removed or damaged.
—
1
10
PMRTUPWH
Touch-up paint pen. Used to repair areas of metal raceway
where paint has been removed or damaged.
—
1
10
PMRTUP**
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
C2.13
ELECTRICAL SOLUTIONS
A.
System
Overview
Cable Fill Capacities for PMR5/PMR7 Metal Raceway
B1.
Cable Ties
This information is to be used as a guide in selecting the proper size raceway. The maximum amounts may vary according
to the cable installation methods, straightness of cables, etc.
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
A = .30 in.2
A = .22 in.2
C2.
Surface
Raceway
C3.
Abrasion
Protection
SPEC = 40% cable fill – The recommended design in cable
capacity, leaves room for future moves, adds, and changes.
MAX for Data = 60% cable fill – The maximum cable quantity based
on cable interweaving and packing factors.
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
Electrical Cables
14 AWG 12 AWG 10 AWG
Raceway Type and
Fill
THHN/T90
Configuration
Area (In.2)
0.111
0.130
0.164
FILL
MAX
MAX
MAX
40%
40%
40%
PMR5
0.22
9
6
4
PMR7
0.30
12
8
5
Data Grade Cables
24 AWG/UTP CM
Category 6
Dia. = 0.250
FILL
SPEC
MAX
40%
60%
1
2
2
3
Data Grade Cables
24 AWG/UTP CM
Category 6A
Dia. = 0.330
FILL
SPEC
MAX
40%
60%
1
1
1
2
Audio/Video
Fiber Optic Cable
RG6
2 Strand
Dia. = 0.275
FILL
SPEC
MAX
40%
60%
1
2
2
3
Dia. = 0.175
FILL
SPEC
MAX
40%
60%
3
5
4
7
AWG dimensions represent typical outer cable diameter in inches.
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.14
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® Metal Raceway Boxes
Part Number
PMR5760WH
PMR5760
PMR5751
PMR5751WH
PMR5751-3
PMR5747-2
Double gang extension box. Box accepts Pan-Way ®
Faceplates or any standard double gang faceplate. For use
with Pan-Way ® PMR5 or PMR7 Raceway. 4.92"L x 4.92"W
x .94"H (125.0mm x 125.0mm x 23.8mm)
White
Three gang extension box. Box accepts Pan-Way ®
Faceplates or any standard three gang faceplate. For use
with Pan-Way® PMR5 or PMR7 Raceway. 4.92"L x 6.72"W
x .94"H (125.0mm x 170.7mm x 23.8mm)
White
Single gang shallow outlet box. Box accepts Pan-Way ®
Faceplates or any NEMA standard single gang faceplate.
For use with Pan-Way ® PMR5 or PMR7 Raceway.
Breakouts for 1/2" conduit. 4.92"L x 3.17"W x 1.38"H
(125.0mm x 80.5mm x 34.9mm)
White
Double gang shallow outlet box. Box accepts Pan-Way®
Faceplates or any standard double gang faceplate. For use
with Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for
1/2" and 1" conduit. 4.92"L x 4.92"W x 1.38"H (125.0mm x
125.0mm x 34.9mm)
White
Three gang shallow outlet box. Box accepts Pan-Way ®
Faceplates or any standard three gang faceplate. For use
with Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for
1/2" conduit. 4.92"L x 6.72"W x 1.38"H (125.0mm x
170.7mm x 34.9mm)
White
Single gang outlet box. Box accepts Pan-Way ® Faceplates
or any NEMA standard single gang faceplate. For use with
Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for 1/2"
conduit. 4.92"L x 3.17"W x 1.75"H (125.0mm x 80.5mm x
44.5mm)
White
1
10
PMR5748-2WH
Double gang outlet box. Box accepts Pan-Way ® Faceplates
or any standard double gang faceplate. For use with
Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for 1/2"
and 1" conduit. 4.92"L x 4.92"W x 1.75"H (125.0mm x
125.0mm x 44.5mm)
White
1
10
D3.
Grounding
Connectors
PMR5748-3WH
Three gang outlet box. Box accepts Pan-Way ® Faceplates
or any standard three gang faceplate. For use with
Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for 1/2"
conduit. 4.92"L x 6.72"W x 1.75"H (125.0mm x 170.7mm x
44.5mm)
White
1
10
E1.
Labeling
Systems
White
1
10
PMR5751-3WH
PMR5747-2WH
PMR5747-3WH
PMR5747-3
PMR5748
PMR5748WH
PMR5748-2
PMR5748-3
PMR5744SWH
PMR5744S
PMR5744S-2
B2.
Cable
Accessories
White
PMR5747WH
PMR5747
B1.
Cable Ties
Single gang extension box. Box accepts Pan-Way ®
Faceplates or any NEMA standard single gang faceplate.
For use with Pan-Way ® PMR5 or PMR7 Raceway. 4.92"L x
3.17"W x .94"H (125.0mm x 80.5mm x 23.8mm)
PMR5751-2WH
PMR5751-2
Part Description
Single gang blank extension box. For use with Pan-Way ®
PMR5 or PMR7 Raceway. 4.92"L x 3.17"W x 0.94"H
(125.0mm x 80.5mm x 23.8mm)
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
White
1
10
Single gang intermediate outlet box. Box accepts
Pan-Way® Faceplates or any NEMA standard single gang
faceplate. For use with Pan-Way ® PMR5 or PMR7
Raceway. Breakouts for 1/2" conduit. 4.92"L x 3.17"W x
2.25"H (125.0mm x 80.5mm x 57.2mm)
PMR5744S-2WH Double gang intermediate outlet box. Box accepts
Pan-Way ® Faceplates or any standard double gang
faceplate. For use with Pan-Way ® PMR5 or PMR7
Raceway. Breakouts for 1/2" and 1" conduit. 4.92"L x
4.92"W x 2.25"H (125.0mm x 125.0mm x 57.2mm)
1
1
1
1
10
10
10
10
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
1
10
C4.
Cable
Management
1
10
D1.
Terminals
White
1
10
‡For other colors replace WH (White) with AL (Almond).
D2.
Power
Connectors
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
Table continues on page C2.16
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
F.
Index
C2.15
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® Metal Raceway Boxes (continued)
B1.
Cable Ties
B2.
Cable
Accessories
PMR5744S-3
PMR5744
Part Description
Part Number
PMR5744S-3WH Three gang intermediate outlet box. Box accepts Pan-Way ®
Faceplates or any standard three gang faceplate. For use
with Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for
1/2" conduit. 4.92"L x 6.72"W x 2.25"H
(125.0mm x 170.7mm x 57.2mm)
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
White
1
10
PMR5744WH
Single gang deep outlet box. Box accepts Pan-Way ®
Faceplates or any NEMA standard single gang faceplate.
For use with Pan-Way ® PMR5 or PMR7 Raceway.
Breakouts for 1/2" conduit. 4.92"L x 3.17"W x 2.75"H
(125.0mm x 80.5mm x 69.9mm)
White
1
10
PMR5744-2WH
Double gang deep outlet box. Box accepts Pan-Way®
Faceplates or any standard double gang faceplate. For use
with Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for
1/2" and 1" conduit. 4.92"L x 4.92"W x 2.75"H
(125.0mm x 80.5mm x 69.9mm)
White
1
10
PMR5744-3WH
Three gang deep outlet box. Box accepts Pan-Way ®
Faceplates or any standard three gang faceplate. For use
with Pan-Way® PMR5 or PMR7 Raceway. Breakouts for
1/2" conduit. 4.92"L x 6.72"W x 2.75"H
(125.0mm x 170.7mm x 69.9mm)
White
1
10
PMR5738WH
Round fixture box with solid base is c-UL-us rated to accept
devices up to 50 lbs. For use with Pan-Way® PMR5 or
PMR7 Raceway. Base has four 1/2" conduit breakouts.
Dia.= 4.77"D x 1.00"H (121.2mm x 25.4mm)
White
1
10
PMR5738AWH
Round fan or fixture box with solid base is c-UL-us rated to
accept devices up to 50 lbs. For use with Pan-Way ® PMR5
or PMR7 Raceway. Base has four 1/2" conduit breakouts.
Dia. = 5.53"D x 1.00"H (140.5mm x 25.4mm)
White
1
10
PMR5739WH
White
1
10
D2.
Power
Connectors
Round fixture box with solid base is c-UL-us rated to accept
devices up to 50 lbs. For use with Pan-Way® PMR5 or
PMR7 Raceway. Base has four 1/2" conduit breakouts.
Dia. = 6.37"D x 1.00"H (161.8mm x 25.4mm)
PMR5737WH
Round extension box with open base is c-UL-us rated to
accept devices up to 50 lbs. For use with Pan-Way ® PMR5
or PMR7 Raceway.
Dia. = 4.76"D x 1.00"H (121.0mm x 25.4mm)
White
1
10
D3.
Grounding
Connectors
PMR5737AWH
Round extension box with open base is c-UL-us rated to
accept devices up to 50 lbs. For use with Pan-Way® PMR5
or PMR7 Raceway.
Dia. = 5.53"D x 1.00"H (140.5mm x 25.4mm)
White
1
10
PMR5739AWH
Round extension box with open base is c-UL-us rated to
accept devices up to 50 lbs. For use with Pan-Way ® PMR5
or PMR7 Raceway.
Dia. = 6.37"D x 1.00"H (161.8mm x 25.4mm)
White
1
10
PMR5736WH
Round Blank Faceplate for use with Pan-Way PMR5 or
PMR7 Round Outlet Boxes: PMR5737, PMR5737A,
PMR5738, PMR5738A, PMR5739 and PMR5739A.
Knockout for 1/2" conduit.
Dia. = 4.25"D x 0.45"H (108.0mm x 11.5mm).
White
1
50
PMR5752RD
Alarm device box. Box accepts alarm devices and safety
signals designed to fit 4" square back boxes. For use with
Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for 1/2"
and 1" conduit. 4.92"L x 4.92"W x 1.42" H (125.0mm x
125.0mm x 36.1mm) Available in red only.
Red
1
10
PMR5753RD
Deep alarm device box. Box accepts alarm devices and
safety signals designed to fit 4" square back boxes. For use
with Pan-Way ® PMR5 or PMR7 Raceway. Breakouts for
1/2" and 1" conduit. 4.92"L x 4.92"W x 2.80"H (125.0mm x
125.0mm x 71.0mm) Available in red only.
Red
1
10
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
PMR5744-2
PMR5744-3
C2.
Surface
Raceway
C3.
Abrasion
Protection
PMR5738
PMR5738A
C4.
Cable
Management
D1.
Terminals
PMR5739
PMR5737A
PMR5737
PMR5739A
E1.
Labeling
Systems
E2.
Labels
PMR5736
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
PMR5753
PMR5752
‡For other colors replace WH (White) with AL (Almond).
F.
Index
C2.16
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Pan-Way ® Metal Raceway Faceplates
MP1GB
MP1GR
MP2GB
MP2GR
MP2G106B
MP2GRB
MP2G106R
MP3GR
MP3G1062TS
MP1G106
MP1TS
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
White
1
10
Part Number
MP1GBWH
Part Description
Metal single gang blank faceplate.
MP1G106WH
Metal single gang 106 duplex faceplate. Covers one
NEMA standard 106 duplex electrical outlet or one
standard 106 communication module frame.
White
1
10
MP1GRWH
Metal single gang rectangular faceplate. Covers one
NEMA standard rectangular electrical outlet or one
standard rectangular communication module frame.
White
1
10
MP1TSWH
Metal single gang toggle switch faceplate. Covers one
NEMA standard toggle switch.
White
1
10
MP2GBWH
Metal double gang blank faceplate.
White
1
10
MP2G106WH
Metal double gang 106 duplex faceplate. Covers two
NEMA standard 106 duplex electrical outlets or two
standard 106 communication module frames.
White
1
10
MP2GRWH
Metal double gang rectangular faceplate. Covers two
NEMA standard rectangular electrical outlets or two
standard rectangular communication module frames.
White
1
10
MP2TSWH
Metal double gang toggle switch faceplate. Covers two
NEMA standard toggle switches.
White
1
10
MP2G106BWH
Metal double gang 106 duplex/blank faceplate. Covers one
NEMA standard 106 duplex electrical outlet or standard
106 communication module frame with opposite
side blank.
White
1
10
MP2G106TSWH
Metal double gang 106 duplex/toggle switch faceplate.
Covers one NEMA standard 106 duplex outlet or standard
106 communication module frame and one NEMA
standard toggle switch.
White
1
10
D1.
Terminals
MP2GRBWH
Metal double gang rectangular/blank faceplate. Covers one White
NEMA standard rectangular electrical outlet or standard
rectangular communication module frame with opposite
side blank.
1
10
D2.
Power
Connectors
MP2GRTSWH
Metal double gang rectangular/toggle switch faceplate.
Covers one NEMA standard rectangular electrical outlet or
standard rectangular communication module frame and
one NEMA standard toggle switch.
White
1
10
D3.
Grounding
Connectors
MP2G106RWH
Metal double gang 106 duplex/rectangular faceplate.
Covers one NEMA standard 106 duplex outlet or standard
106 communication module frame and one NEMA
standard rectangular outlet or standard rectangular
communication module frame.
White
1
10
E1.
Labeling
Systems
MP3G106WH
Metal three gang 106 duplex faceplate. Covers three
NEMA standard 106 duplex electrical outlets or three
standard 106 communication module frames.
White
1
10
E2.
Labels
MP3GRWH
Metal three gang rectangular faceplate. Covers three
NEMA standard rectangular electrical outlets or three
standard rectangular communication module frames.
White
1
10
E3.
Pre-Printed
& Write-On
Markers
MP3TSWH
Metal three gang toggle switch faceplate. Covers three
NEMA standard toggle switches.
White
1
10
MP3G1062TSWH
Metal three gang 106 duplex/two toggle switch faceplate.
Covers one NEMA standard 106 duplex electrical outlet or
one standard 106 communication module frame and two
NEMA standard toggle switches.
White
1
10
MP2G106
MP2TS
MP2G106TS
MP2GRTS
MP3G106
MP3TS
B1.
Cable Ties
‡For other colors replace WH (White) with AL (Almond).
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
C2.17
ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
PAN-WAY ® NON-METALLIC SURFACE RACEWAY
Pan-Way ® Non-Metallic Surface Raceways provide maximum flexibility for routing, protecting,
concealing and terminating high performance copper, voice, video, fiber optic and power cabling.
Panduit surface raceways are designed with attention to function and aesthetics to blend with any décor.
Panduit surface raceway systems include transition fittings that facilitate seamless integration of one
Panduit surface raceway system to another. Panduit Surface Raceway Systems work with all
Panduit ® Mini-Com ® Modules for complete connectivity possibilities.
C1.
Wiring
Duct
• Aesthetically pleasing
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
• Lightweight
• Tamper resistant
• Bend radius control
• Resists dents and conceals scratches and chips
• Ease of modifications and additions
• Lowest installed cost
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
C2.18
Panduit surface raceway provides a variety of choices when selecting data and electrical terminations.
All Panduit surface raceways include a full complement of fittings that are designed to maintain the
proper bend radius control required for high performance copper and fiber optic cabling systems.All of
the raceways accept either NEMA 70mm standard screw-on faceplates or superior Pan-Way ® Snap-On
Faceplates.Panduit surface raceway systems work with all Panduit ® Mini-Com ® Modules, for complete