Commercial Construction
Pocket Guide
PANDUIT
NetKey®
Table of Contents
Contractor Grade Solutions
for Electrical and Networking Installations
A. StrongHold™ Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . A.1 - A.18
StrongHold™ Cable Tie Accessories
Panduit brings you three strong brands in a collaborative approach
B. StrongHold™ Stainless Steel Cable Ties . . . . . . . . . . . B.1 - B.8
to provide a competitive advantage to our customers in the con-
C. StrongHold™ PVC Electrical Tape . . . . . . . . . . . . . . . . . . C.1 - C.6
tractor market space. Panduit offers a unique understanding of the
D. Panduit Specialty Tapes . . . . . . . . . . . . . . . . . . . . . . . . . . D.1 - D.4
complexities of infrastructure construction and continually develops
new application systems focused on meeting the constantly adapting
E. StrongHold™ Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . E.1 - E.9
installation and maintenance needs of our customers. Whether the
F. StrongHold™ Pigtails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F.1 - F.4
solution is for electrical or networking systems Panduit continually
G. StrongHold™ Wire Marker Books . . . . . . . . . . . . . . . . . . G.1 - G.3
strives to bring you the best option for your application needs.
H. StrongHold™ Supports & Fasteners . . . . . . . . . . . . . . . H.1 - H.29
Cable/Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.2 - H.19
Beam/Purlin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.20 - H.31
Hangers/Hanging Systems . . . . . . . . . . . . . . . . . . . H.32 - H.33
Stud Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.34 - H.50
Communication/Low Voltage . . . . . . . . . . . . . . . . . H.51 - H.66
Dry Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.67 - H.68
Acoustical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.69 - H.78
Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.79 - H.82
Panduit®
Panduit is committed to providing our contractor partners a comprehensive assortment of products, programs, and services. Our
collaborative approach addresses the greatest business challenges
for the contractor community and provides a competitive advantage
in your market space.
StrongHold™
StrongHold™ helps our customers achieve their goals by providing
I. Panduit Duct Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.1 - I.2
an assortment of reliable, convenient and economical electrical
J. NetKey® Cabling Systems . . . . . . . . . . . . . . . . . . . . . . . J.1 - J.16
products, delivering the quality standards electrical contractors can
rely on. We are continually adding to our portfolio in order to provide
K. Convenient Sizing Information . . . . . . . . . . . . . . . . . . . . K.1 - K.8
the most comprehensive offering of innovative electrical solutions
L. Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . L.1 - L.19
that contractors can trust to get the job done.
M. Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M.1 - M.7
NetKey®
The NetKey® Copper and Fiber Cabling System provides a complete,
standards compliant cabling infrastructure solution for voice, data
and video applications. NetKey® Modules feature the universal
“keystone” design and are compatible with a wide assortment of
modular patch panels, faceplates and surface mount boxes.
For complete program details, go to www.panduit.com or contact Customer Service
at 800.777.3300. All programs and benefits subject to terms and conditions.
ii
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
iii
Cable Ties
StrongHold™ offers contractors economical cable tie options for
commercial construction including locking, releasable, and clamp ties.
The line features a variety of plenum-rated nylon cable ties in natural,
UV weather resistant black, and red, suitable for both indoor and outdoor
applications. In addition, StrongHold™ offers a comprehensive assortment
of cable tie mounts to complement our cable tie offering. Our mounts
feature Adhesive Back Mounts and Screw Mounts in natural and black
nylon materials, suitable for securing wires and cables quickly. Combined
with StrongHold™ cable ties, our mounts offer you the best routing solution
for your application needs.
StrongHold ™ Cable Ties
StrongHold™ Contractor Grade Cable Ties
Application
Environments
95+ Part Numbers
• Suitable for general purpose, light
commercial, contractor, residential
and HVAC applications
• No controlled tension during
installation
(not for use with cable tie
installation tool)
Materials/Environment
• Nylon 6.6 in natural and in UV
weather resistant black
– Suitable for Plenum spaces
– Black UV suitable for outdoor
use
Tie Construction (Cross-Sectional Area)
• Available in Miniature,
Intermediate, Standard, Light
Heavy, and Heavy
– Loop tensile strength 18, 40, 50,
120 and
www.panduit.com/StrongHold
175 lbs.
– Tie lengths 3.9" to 48.0"
– Bundle diameters to 14.3"
Product
Offering
Operating Temperature
• -40°C to 85°C
Compliance
Ratings
Project
Based Pricing
—
Application
Support
—
Pricing
A.1
Order number of pieces required, in multiples of Standard Package Quantity.
cULus Listed to UL 62275 Type 2,21
Value Price Model
Call 866-405-6654 or visit www.panduit.com/stronghold
A.2
Cable Ties
Cable Ties
Part
Number
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Miniature Cable Ties 18 lbs (80N)
S4-18-C
S4-18-M
S4-18-C0
S4-18-M0
S6-18-C
S6-18-M
S6-18-C0
S6-18-M0
S8-18-C
S8-18-M
S8-18-C0
S8-18-M0
3.94
(100)
3.94
(100)
3.94
(100)
3.94
(100)
6.30
(160)
6.30
(160)
6.30
(160)
6.30
(160)
7.87
(200)
7.87
(200)
7.87
(200)
7.87
(200)
0.87
(22)
0.87
(22)
0.87
(22)
0.87
(22)
1.57
(40)
1.57
(40)
1.57
(40)
1.57
(40)
2.09
(53)
2.09
(53)
2.09
(53)
2.09
(53)
S12-40-C
5.51
(140)
5.51
(140)
5.51
(140)
5.51
(140)
7.87
(200)
7.87
(200)
7.87
(200)
7.87
(200)
11.81 (300)
S12-40-M
11.81 (300)
S12-40-C0
11.81 (300)
S12-40-M0
11.81 (300)
S15-40-C
14.57 (370)
S15-40-C0
14.57 (370)
S6-40-M
S6-40-C0
S6-40-M0
S8-40-C
S8-40-M
S8-40-C0
S8-40-M0
A.3
1.30
(33)
1.30
(33)
1.30
(33)
1.30
(33)
2.09
(53)
2.09
(53)
2.09
(53)
2.09
(53)
2.99
(76)
2.99
(76)
2.99
(76)
2.99
(76)
4.02
(102)
4.02
(102)
Color
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Miniature Cable Ties 18 lbs (80N)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
0.10
(2.5)
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
Intermediate Cable Ties 40 lbs (178 N)
S6-40-C
StrongHold ™ Cable Tie Part Numbers
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
0.14
(3.6)
Intermediate Cable Ties 40 lbs (178 N)
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
100
Black
3
No
3
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.4
Cable Ties
Cable Ties
Part
Number
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Standard Cable Ties 50 lbs (222 N)
S5-50-C
S12-50-C
4.72
(120)
4.72
(120)
4.72
(120)
4.72
(120)
6.30
(160)
6.30
(160)
6.30
(160)
6.30
(160)
7.40
(188)
7.40
(188)
7.40
(188)
7.40
(188)
7.40
(188)
8.46
(215)
8.46
(215)
8.46
(215)
8.46
(215)
8.46
(215)
8.46
(215)
11.81 (300)
S12-50-M
11.81 (300)
S12-50-C0
11.81 (300)
S12-50-M0
11.81 (300)
S12-50-C2
11.81 (300)
S15-50-C
14.57 (370)
S5-50-M
S5-50-C0
S5-50-M0
S6-50-C
S6-50-M
S6-50-C0
S6-50-M0
S7-50-C
S7-50-M
S7-50-C0
S7-50-M0
S7-50-C2
S8-50-C
S8-50-M
S8-50-C0
S8-50-M0
S10-50-C
S10-50-C0
A.5
StrongHold ™ Cable Tie Part Numbers
0.94
(24)
0.94
(24)
0.94
(24)
0.94
(24)
1.50
(38)
1.50
(38)
1.50
(38)
1.50
(38)
1.81
(46)
1.81
(46)
1.81
(46)
1.81
(46)
1.81
(46)
2.09
(53)
2.09
(53)
2.09
(53)
2.09
(53)
2.09
(53)
2.09
(53)
2.99
(76)
2.99
(76)
2.99
(76)
2.99
(76)
2.99
(76)
4.02
(102)
Color
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Standard Cable Ties 50 lbs (222 N)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
0.19
(4.8)
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Red
3
No
3
3
100
Natural
3
3
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Natural
3
No
3
3
100
Black
3
3
3
3
100
Natural
3
No
3
3
1000
Natural
3
No
3
3
100
Black
3
3
3
3
1000
Black
3
3
3
3
100
Red
3
No
3
3
100
Natural
3
No
3
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.6
Cable Ties
Cable Ties
Part
Number
A.7
StrongHold ™ Cable Tie Part Numbers
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Color
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Standard Cable Ties 50 lbs (222 N) (continued)
Standard Cable Ties 50 lbs (222 N) (continued)
S15-50-M
14.57
(370)
4.02 (102)
0.19 (4.8)
1000
Natural
3
No
3
3
S15-50-C0
14.57
(370)
4.02 (102)
0.19 (4.8)
100
Black
3
3
3
3
S15-50-M0
14.57
(370)
4.02 (102)
0.19 (4.8)
1000
Black
3
3
3
3
S15-50-C2
14.57
(370)
4.02 (102)
0.19 (4.8)
100
Red
3
No
3
3
S17-50-C
16.90
(430)
4.33 (110)
0.19 (4.8)
100
Natural
3
No
3
3
S17-50-M
16.90
(430)
4.33 (110)
0.19 (4.8)
1000
Natural
3
No
3
3
S17-50-C0
16.90
(430)
4.33 (110)
0.19 (4.8)
100
Black
3
3
3
3
S17-50-M0
16.90
(430)
4.33 (110)
0.19 (4.8)
1000
Black
3
3
3
3
S21-50-C
20.87
(530)
5.51 (140)
0.19 (4.8)
100
Natural
3
No
3
3
S21-50-M
20.87
(530)
5.51 (140)
0.19 (4.8)
1000
Natural
3
No
3
3
S21-50-C0
20.87
(530)
5.51 (140)
0.19 (4.8)
100
Black
3
3
3
3
S21-50-M0
20.87
(530)
5.51 (140)
0.19 (4.8)
1000
Black
3
3
3
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.8
Cable Ties
Cable Ties
Part
Number
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Color
Light Heavy Cable Ties 120 lbs (534 N)
A.9
StrongHold ™ Cable Tie Part Numbers
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Light Heavy Cable Ties 120 lbs (534 N)
S14-120-L
14.49
(368)
4.02 (102)
0.30 (7.6)
50
Natural
3
No
3
3
S14-120-TL
14.49
(368)
4.02 (102)
0.30 (7.6)
250
Natural
3
No
3
3
S14-120-L0
14.49
(368)
4.02 (102)
0.30 (7.6)
50
Black
3
3
3
3
S14-120-TL0
14.49
(368)
4.02 (102)
0.30 (7.6)
250
Black
3
3
3
3
S18-120-L
17.71
(450)
5.12 (130)
0.30 (7.6)
50
Natural
3
No
3
3
S18-120-L0
17.71
(450)
5.12 (130)
0.30 (7.6)
50
Black
3
3
3
3
S21-120-L
20.98
(533)
5.51 (140)
0.30 (7.6)
50
Natural
3
No
3
3
S21-120-C
20.98
(533)
5.51 (140)
0.30 (7.6)
100
Natural
3
No
3
3
S21-120-L0
20.98
(533)
5.51 (140)
0.30 (7.6)
50
Black
3
3
3
3
S21-120-C0
20.98
(533)
5.51 (140)
0.30 (7.6)
100
Black
3
3
3
3
S24-120-Q
23.62
(600)
6.89 (175)
0.30 (7.6)
25
Natural
3
No
3
3
S24-120-L
23.62
(600)
6.89 (175)
0.30 (7.6)
50
Natural
3
No
3
3
S24-120-Q0
23.62
(600)
6.89 (175)
0.30 (7.6)
25
Black
3
3
3
3
S24-120-L0
23.62
(600)
6.89 (175)
0.30 (7.6)
50
Black
3
3
3
3
S30-120-X
29.53
(750)
8.58 (218)
0.30 (7.6)
10
Natural
3
No
3
3
S30-120-L
29.53
(750)
8.58 (218)
0.30 (7.6)
50
Natural
3
No
3
3
S30-120-X0
29.53
(750)
8.58 (218)
0.30 (7.6)
10
Black
3
3
3
3
S30-120-L0
29.53
(750)
8.58 (218)
0.30 (7.6)
50
Black
3
3
3
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.10
Cable Ties
Cable Ties
Part
Number
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Color
Heavy Cable Ties 175 lbs (778 N)
A.11
StrongHold ™ Cable Tie Part Numbers
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Heavy Cable Ties 175 lbs (778 N)
S18-175-L
17.71
(450)
5.20
(132)
0.35
(9.0)
50
Natural
3
No
3
3
S18-175-L0
17.71
(450)
5.20
(132)
0.35
(9.0)
50
Black
3
3
3
3
S21-175-L
20.86
(530)
5.51
(140)
0.35
(9.0)
50
Natural
3
No
3
3
S21-175-C
20.86
(530)
5.51
(140)
0.35
(9.0)
100
Natural
3
No
3
3
S21-175-L0
20.86
(530)
5.51
(140)
0.35
(9.0)
50
Black
3
3
3
3
S21-175-C0
20.86
(530)
5.51
(140)
0.35
(9.0)
100
Black
3
3
3
3
S24-175-L
24.02
(610)
7.36
(187)
0.35
(9.0)
50
Natural
3
No
3
3
S24-175-L0
24.02
(610)
7.36
(187)
0.35
(9.0)
50
Black
3
3
3
3
S31-175-L
30.55
(776)
8.98
(228)
0.35
(9.0)
50
Natural
3
No
3
3
S31-175-L0
30.55
(776)
8.98
(228)
0.35
(9.0)
50
Black
3
3
3
3
S32-175-L
32.12
(816)
9.41
(239)
0.35
(9.0)
50
Natural
3
No
3 (also UL181)
3
S32-175-L0
32.12
(816)
9.41
(239)
0.35
(9.0)
50
Black
3
3
3 (also UL181)
3
S36-175-L
35.91
(912)
10.35
(263)
0.35
(9.0)
50
Natural
3
No
3 (also UL181)
3
S36-175-L0
35.91
(912)
10.35
(263)
0.35
(9.0)
50
Black
3
3
3 (also UL181)
3
S40-175-X
40.16
(1020)
11.61
(295)
0.35
(9.0)
10
Natural
3
No
3 (also UL181)
3
S40-175-L
40.16
(1020)
11.61
(295)
0.35
(9.0)
50
Natural
3
No
3 (also UL181)
3
S40-175-X0
40.16
(1020)
11.61
(295)
0.35
(9.0)
10
Black
3
3
3 (also UL181)
3
S40-175-L0
40.16
(1020)
11.61
(295)
0.35
(9.0)
50
Black
3
3
3 (also UL181)
3
S48-175-L
48.03
(1220)
14.37
(365)
0.35
(9.0)
50
Natural
3
No
3 (also UL181)
3
S48-175-L0
48.03
(1220)
14.37
(365)
0.35
(9.0)
50
Black
3
3
3 (also UL181)
3
S48-175-L8
48.03
(1220)
14.37
(365)
0.35
(9.0)
50
Gray
3
No
3 (also UL181)
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.12
Cable Ties
Cable Ties
Part
Number
Cable Ties
Length
In. (mm)
Max.
Bundle
Dia.
In. (mm)
Width
In. (mm)
Std.
Pkg.
Qty.
Color
Cable Ties, Releasable, 50 lbs (222 N)
AH-2
Plenum Rated
UV
Resistant
cULus Listed
62275
Type 2,21
CE
Declaration
Cable Ties, Releasable, 50 lbs (222 N)
SR8-50-C
7.87
(200)
1.97
(50)
0.19
(4.8)
100
Natural
3
No
3
3
SR8-50-C0
7.87
(200)
1.97
(50)
0.19
(4.8)
100
Black
3
3
3
3
Cable Ties, Clamp Style, 50 lbs (222 N) - Clamp
Mount takes #10 / M5 Screw
Cable Ties, Clamp Style, 50 lbs (222 N) Clamp Mount takes #10 / M5 Screw
SC8-50-S10-C
7.87
(200)
1.85
(47)
0.19
(4.8)
100
Natural
No
No
3
3
SC8-50-S10-C0
7.87
(200)
1.85
(47)
0.19
(4.8)
100
Black
No
3
3
3
Cable Ties, Clamp Style, 50 lbs (222 N) - Clamp
Mount takes #10 / M5 Screw
A.13
StrongHold ™ Cable Tie Part Numbers
Cable Ties, Clamp Style, 50 lbs (222 N) Clamp Mount takes #10 / M5 Screw
SC15-120-S25-L
14.96
(380)
3.86
(98)
0.30
(7.6)
50
Natural
3
No
3
3
SC15-120-S25-L0
14.96
(380)
3.86
(98)
0.30
(7.6)
50
Black
3
3
3
3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.14
Cable Tie
Accessories
Low Profile Cable Tie Anchor Mounts
Low Profile Cable Tie Anchor Mounts
Length
In. (mm)
Width
In. (mm)
Height
In. (mm)
SSMTA-M
0.75
(19.0)
0.38
(9.5)
0.20
(5.1)
Nylon 6.6
SSMTA-C
0.75
(19.0)
0.38
(9.5)
0.20
(5.1)
Nylon 6.6
Part
Number
Anchor Mounts
Part
Number
Material
Hole
Diameter
In. (mm)
Mounting
Method
Std.
Pkg.
Qty.
Std.
Pkg.
Qty.
S*-18, S*-40,
S*-50
0.17 (4.3)
#8 (M4) Screw
1000
5000
S*-18, S*-40,
S*-50
0.17 (4.3)
#8 (M4) Screw
100
500
Used with
Stronghold
Cable Ties
Anchor Mounts
Standard Screw Applied Cable Tie Mounts
Length
In. (mm)
Standard Screw Applied Cable Tie Mounts
Width
In. (mm)
Height
In. (mm)
Material
Cable Tie Mounts
A.15
StrongHold ™ Cable Tie Accessories Part Numbers
Used with
Stronghold
Cable Ties
Hole
Diameter
In. (mm)
Mounting
Method
Std.
Pkg.
Qty.
Std.
Pkg.
Qty.
Cable Tie Mounts
SSM2S6-M
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
1000
5000
SSM2S6-C
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
100
500
SSM2S6-3X
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
30
300
SS2S6-M0
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
Weather
Resistant
Nylon 6.6
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
1000
5000
SSM2S6-C0
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
Weather
Resistant
Nylon 6.6
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
100
500
SSM2S6-3X0
0.63 (16.0)
0.43 (10.8)
0.28 (7.0)
S*-18, S*-40,
S*-50
0.29 (7.1)
#6 (M3) Screw
30
300
SSM3S8-M
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Weather
Resistant
Nylon 6.6
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
1000
5000
SSM3S8-C
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
100
500
SSM3S8-3X
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
30
300
SSM3S8-M0
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Weather
Resistant
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
1000
5000
SSM3S8-C0
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Weather
Resistant
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
100
500
SSM3S8-3X0
0.86 (21.9)
0.61 (15.5)
0.37 (9.4)
Weather
Resistant
Nylon 6.6
S*-18, S*-40,
S*-50, S*-120
0.32 (8.1)
#8 (M4) Screw
30
300
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.16
Cable Ties
Accessories
Low Profile Screw Applied Cable Tie Mounts
Part
Number
Length
In. (mm)
Width
In. (mm)
Height
In. (mm)
Cable Tie Mounts
Low Profile Screw Applied Cable Tie Mounts
Material
Used with
Stronghold
Cable Ties
Hole
Diameter
In. (mm)
Mounting
Method
Std.
Pkg.
Qty.
Std.
Pkg.
Qty.
Cable Tie Mounts
SSMLP-M
0.75
(19.1)
0.50
(12.7)
0.12
(3.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.164
(4.2)*
#8 (M4)
Countersunk
Screw
1000
5000
SSMLP-C
0.75
(19.1)
0.50
(12.7)
0.12
(3.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.164
(4.2)*
#8 (M4)
Countersunk
Screw
100
500
SSMLP-3X
0.75
(19.1)
0.50
(12.7)
0.12
(3.0)
Nylon 6.6
S*-18, S*-40,
S*-50
0.164
(4.2)*
#8 (M4)
Countersunk
Screw
30
300
Adhesive Backed Mounts
Adhesive Backed Mounts
Size
(LxW)
(mm)
Size
(LxW)
(In)
Material
SMP12A-3X
.787x.787
20x20
Nylon 6.6
S*-18, S*-40
30
300pcs
SMP12A-C
.787x.787
20x20
Nylon 6.6
S*-18, S*-40
100
1000pcs
Part
Number
Cable Tie Mounts
A.17
StrongHold ™ Cable Tie Accessories Part Numbers
Used with
Stronghold
Cable Ties
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Cable Tie Mounts
SMP12A-M
.787x.787
20x20
Nylon 6.6
S*-18, S*-40
1000
5000pcs
SMP16A-3X
1" X 1"
25x25
Nylon 6.6
S*-18, S*-40,
S*-50
30
300pcs
SMP16A-C
1" X 1"
25x25
Nylon 6.6
S*-18, S*-40,
S*-50
100
1000pcs
SMP16A-M
1" X 1"
25x25
Nylon 6.6
S*-18, S*-40,
S*-50
1000
5000pcs
SMP18A-3X
1.18x1.18
30x30
Nylon 6.6
S*-18, S*-40,
S*-50
30
300pcs
SMP18A-C
1.18x1.18
30x30
Nylon 6.6
S*-18, S*-40,
S*-50
100
1000pcs
SMP18A-M
1.18x1.18
30x30
Nylon 6.6
1000
5000pcs
SMP12A-3X0
.787x.787
20x20
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
S*-18, S*-40
30
300pcs
SMP12A-C0
.787x.787
20x20
Nylon 6.6
(Black)
S*-18, S*-40
100
1000pcs
SMP12A-M0
.787x.787
20x20
Nylon 6.6
(Black)
S*-18, S*-40
1000
5000pcs
SMP16A-3X0
1" X 1"
25x25
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
30
300pcs
SMP16A-C0
1" X 1"
25x25
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
100
1000pcs
SMP16A-M0
1" X 1"
25x25
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
1000
5000pcs
SMP18A-3X0
1.18x1.18
30x30
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
30
300pcs
SMP18A-C0
1.18x1.18
30x30
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
100
1000pcs
SMP18A-M0
1.18x1.18
30x30
Nylon 6.6
(Black)
S*-18, S*-40,
S*-50
1000
5000pcs
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
A.18
Stainless Steel
Cable Ties
StrongHold ™ Stainless Steel Cable Ties
StrongHold offers a comprehensive selection of stainless steel products
such as Metal Locking Ties (IMLT) and Custom Length Strapping (IMS) in
uncoated and fully coated options to deliver high performance, strength,
and reliability against harsh environments.
StrongHold™ Stainless Steel Cable Ties
PANDUIT
Application
Environments
Materials/Environment
IMLTs:
Available in AISI 304 stainless steel
for general purpose applications and
AISI 316L stainless steel for the
most corrosive environments
PANDUIT
Product
Offering
Order number of pieces required, in multiples of Standard Package Quantity.
MLTFCs:
Epoxy polyester coating available in
black only
Made in China with non-DFARS
Steel
Tie Construction
(Cross-Sectional Area)
Available in standard and heavy
Loop Tensile Strength:
100 to 200 Lbs. (445 to 890N)
Product
Availability
Available on request 8-10 week lead
time
Application
Support
—
Pricing
B.1
66+ Part Numbers
Suitable for the following verticals:
• Chemical Plants and Refineries
• Industrial Construction
• Mining
• Oil and Gas
• MRO
• Shipbuilding
• General Applications requiring
Cable Management
Value Price Model
Call 866-405-6654 or visit www.panduit.com/stronghold
B.2
Stainless Steel
Cable Ties
Material
Min Loop
Tensile
Strength
(N)
Length
(mm)*
Width
(mm)
StrongHold™ Self-Locking Cable Ties
PANDUIT
PANDUIT
Part Number
Max Bundle Min Bundle
Diameter
Diameter
(mm)
(mm)
StrongHold ™ Stainless Steel Cable Tie Part Numbers
Thickness
(mm)
Recommended Tool
Std
Pkg
Qty
Std
Ctn
Qty
StrongHold™ Self-Locking Cable Ties
25
12.7
556
127
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
304
51
12.7
556
201
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT69S-C
304
69
12.7
556
259
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT102S-C
304
102
12.7
556
362
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT152S-C
304
152
12.7
556
521
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT203S-C
304
203
12.7
556
679
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT254S-C
304
254
12.7
556
838
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT304S-Q
304
304
12.7
556
998
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT355S-Q
304
355
12.7
556
1156
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT380S-Q
304
380
12.7
556
1250
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT25S-C6L
316L
25
12.7
556
127
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT51S-C6L
316L
51
12.7
556
201
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT69S-C6L
316L
69
12.7
556
259
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT102S-C6L
316L
102
12.7
556
362
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT152S-C6L
316L
152
12.7
556
521
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT203S-C6L
316L
203
12.7
556
679
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT254S-C6L
316L
254
12.7
556
838
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLT304S-Q6L
316L
304
12.7
556
998
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT355S-Q6L
316L
355
12.7
556
1156
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT380S-Q6L
316L
380
12.7
556
1250
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
25
125
IMLT51H-L
304
51
12.7
890
201
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT69H-L
304
69
12.7
890
259
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT102H-L
304
102
12.7
890
362
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT152H-L
304
152
12.7
890
521
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT203H-L
304
203
12.7
890
679
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT254H-L
304
254
12.7
890
838
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT304H-Q
304
304
12.7
890
998
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
25
125
IMLT355H-Q
304
355
12.7
890
1156
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
25
125
IMLT51H-L6L
316L
51
12.7
890
201
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT69H-L6L
316L
69
12.7
890
259
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT102H-L6L
316L
102
12.7
890
362
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT152H-L6L
316L
152
12.7
890
521
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT203H-L6L
316L
203
12.7
890
679
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT254H-L6L
316L
254
12.7
890
838
7.9
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
50
250
IMLT304H-Q6L
IMLT355H-Q6L
316L
316L
304
355
12.7
12.7
890
890
998
1156
7.9
7.9
0.25
0.25
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
25
25
125
125
B.3
PANDUIT
304
IMLT51S-C
PANDUIT
IMLT25S-C
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
B.4
Stainless Steel
Cable Ties
Material
IMLTFC38S-C6L
IMLTFC51S-C6L
IMLTFC64S-C6L
IMLTFC86S-C6L
IMLTFC102S-C6L
316L
316L
316L
316L
316L
38
51
64
86
102
12.7
12.7
12.7
12.7
12.7
445
445
445
445
445
158
201
233
310
362
4.6
4.6
4.6
4.6
4.6
0.25
0.25
0.25
0.25
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT
100
100
100
100
100
500
500
500
500
500
IMLTFC137S-C6L
316L
137
12.7
445
462
4.6
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
100
500
IMLTFC152S-C6L
IMLTFC203S-C6L
IMLTFC38H-C6L
IMLTFC51H-L6L
IMLTFC64H-C6L
IMLTFC69H-L6L
IMLTFC86H-C6L
IMLTFC102H-L6L
IMLTFC137H-C6L
IMLTFC152H-L6L
IMLTFC203H-L6L
316L
316L
316L
316L
316L
316L
316L
316L
316L
316L
316L
152
203
38
51
64
69
86
102
137
152
203
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
12.7
445
445
890
890
890
890
890
890
890
890
890
521
679
158
201
233
259
310
362
462
521
679
4.6
4.6
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT
100
100
100
50
100
50
100
50
100
50
50
500
500
500
250
500
250
500
250
500
250
250
Call 866-405-6654 or visit www.panduit.com/stronghold
B.6
Part Number
Max Bundle Min Bundle
Diameter
Diameter
(mm)
(mm)
Length
(mm)
Width
(mm)
StrongHold™ Self-Locking Fully Coated Cable Ties
B.5
PANDUIT
PANDUIT
Min Loop
Tensile
Strength
(N)
StrongHold ™ Stainless Steel Cable Tie Part Numbers
Thickness
(mm)
Recommended Tool
Std
Pkg
Qty
Std
Ctn
Qty
StrongHold™ Self-Locking Fully Coated Cable Ties
Order number of pieces required, in multiples of Standard Package Quantity.
Stainless Steel
Straps and Buckles
Part Number
Material
Length
M
Strap
Breaking
Strength
N
StrongHold™ Metal Strapping (Uncoated) - Coil
StrongHold™ Stainless Steel Straps and Buckles Part Numbers
Min
Bundle
Diameter
mm
Width
mm
Thickness
mm
Recommended
Installation Tool
Std.
Pkg.
Qty.
StrongHold™ Metal Strapping (Uncoated) - Coil
IMS9.5T35-QR6L
Stainless Steel Type 316L
25
1780
26
9.5
0.35
BT75SDT
1
IMS12T35-QR6L
Stainless Steel Type 316L
25
2445
26
12
0.35
BT75SDT
1
IMS16T35-QR6L
Stainless Steel Type 316L
25
3110
26
16
0.35
BT75SDT
1
IMS19T75-QR6L
Stainless Steel Type 316L
25
4225
26
19
0.75
BT75SDT
1
StrongHold™ Metal Strapping (Coated with Epoxy Polyester) - Coil
StrongHold™ Metal Strapping (Coated with Epoxy Polyester) - Coil
IMSP9.5T35-QR6L
Stainless Steel Type 316L
25
1780
26
9.5
0.35^
BT75SDT
1
IMSP12T35-QR6L
Stainless Steel Type 316L
25
2445
26
12
0.35^
BT75SDT
1
IMSP16T35-QR6L
Stainless Steel Type 316L
25
3110
26
16
0.35^
BT75SDT
1
^Base material less coating
Part Number
Material
Width
mm
StrongHold Buckles
Part Description
Std.
Pkg.
Qty.
StrongHold™ Buckles
™
IMSBL9.5-C6L
Stainless Steel Type 316L
9.5
Individual Buckle Style L for use with 9.5 mm strapping
100
IMSBL12-C6L
Stainless Steel Type 316L
12
Individual Buckle Style L for use with 12 mm strapping
100
IMSBL16-C6L
Stainless Steel Type 316L
16
Individual Buckle Style L for use with 16 mm strapping
100
IMSBE19-C6L
Stainless Steel Type 316L
19
Individual Buckle Style E for use with 19 mm strapping
100
B.7
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
B.8
PVC Tape
PVC Electrical Tape
StrongHold offers a broad range of pressure-sensitive vinyl
electrical tape suitable for a wide range of indoor and outdoor
applications and temperatures. Whether your application
calls for high end performance over a range of temperatures,
primary insulation for splicing, phase identification or high
resistance to sun, water, oil, acids, alkalis, and corrosive
chemicals; StrongHold Heavy Duty, Professional Grade and
General Purpose line of electrical tapes have you covered.
Not sure which grade of tape is necessary for your application?
Take a look at our chart to compare options.
Professional
Grade
Heavy Duty
ST35
ST88
General Purpose
ST43
ST14
ST17
HEAVY
DUTY
PROFESSIONAL
GENERAL
PURPOSE
8.5 mil
7.0 mil
7.0 mil
Thickness
Low temperature
rating
0°F
-18°C
0°F
-18°C
14°F
-10°C
High temperature
rating
221°F
105°C
221°F
105°C
176°F
80°C
Sticking power
2.2 N/cm TYP
2.2 N/cm TYP
1.6-1.8 N/cm
300% TYP
260% TYP
200% TYP
38 N/cm TYP
30 N/cm TYP
25 N/cm TYP
Elongation
Breaking strength
Color
C.1
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
C.2
PVC Electrical Tape
StrongHold™ PVC Electrical Tape
Application
Environments
27+ Part Numbers
• A primary insulation when used for
splicing up 600 Volts
• A protective outer jacket over
splices in low temperature
applications
Product Types:
– Heavy Duty
– Professional Grade
– General Purpose
Materials/Environments
• Pressure sensitive vinyl adhesives
backed electrical tape
Product
Offering
Suitable for a range of applications
including:
• A primary insulation when used for
splicing up 600 Volts
• A protective outer jacket over
splices in low temperature
applications
– Cold resistant
www.panduit.com/StrongHold
– Flame Retardant
– High dielectric strength
– High elastic
– Highly resistant to water,
oil, acids, alkalies, corrosive
chemicals, and ultraviolet rays
Panduit® PVC Tape Part Numbers
ST88 Heavy Duty Tape
StrongHold ST88 Series Heavy Duty PVC Electrical Tape is a 0.21
mm (8.5 mil) is an all-weather, pressure sensitive vinyl electrical
tape that applies easily and provides a high level of performance
over a range of temperatures. The ST88 series product is flame
retardant and cold resistant. ST88 is suitable as a primary insulation
when used for splicing up 600 Volts and can be used as a protective
outer jacket over splices in low temperature applications.
Heavy Duty Electrical PVC Vinyl Tape Offering
Part Number
Case
Qty
Minimum
Order Qty
ST88-075-66BK
100
20
ST88-100-108BK
80
20
ST88-150-66BK
100
20
ST88-200-66BK
40
20
Color
Thickness
Dimension
3/4"x.0085"x66'
Black
8.5 mil
1"x.0085"x108'
1.5"x.0085"x66'
2"x.0085"x66'
Operating Temperature
• ST88 , ST35 and ST43 Series:
-18° C to 105° C
• ST17 and ST14 Series: -10° C
to 80° C
• ST15: Up to 80° C
Compliance
Ratings
C.3
•
•
•
•
UL 510, CSA C 22.2 No. 197
EN 60454-1-1, Type II
Meets ASTM D-3005
Meets 2000/53/EC and RoHS
2011/65/EU Directives
• Pd, Cd, Hg, Cr (VI) free
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
C.4
PVC Electrical Tape
ST35 & ST43 Professional Grade Tape
StrongHold ST35 Series Professional Grade PVC Electrical Tape is
a 0.18 mm (7 mil) is a pressure sensitive vinyl electrical tape that
applies easily and provides a high level of performance over a range
of temperatures. The ST35 series product is flame retardant and
cold resistant. ST35 is suitable as a primary insulation when used
for splicing up 600 Volts and can be used as a protective outer
jacket over splices in low temperature applications.
Professional Grade Electrical
PVC VInyl Tape Offering
Case
Qty
Minimum
Order Qty
Color
Thickness
Dimension
ST35-075-66BU
20
20
Blue
7 mil
0.75" x 0.007" x 66'
ST35-075-66BR
20
20
Brown
7 mil
0.75" x 0.007" x 66'
ST35-075-66GY
20
20
Gray
7 mil
0.75" x 0.007" x 66'
Part Number
ST35-075-66GR
20
20
Green
7 mil
0.75" x 0.007" x 66'
ST35-075-66OR
20
20
Orange
7 mil
0.75" x 0.007" x 66'
ST35-075-66RD
20
20
Red
7 mil
0.75" x 0.007" x 66'
ST35-075-66VI
20
20
Violet
7 mil
0.75" x 0.007" x 66'
ST35-075-66WH
20
20
White
7 mil
0.75" x 0.007" x 66'
ST35-075-66YL
20
20
Yellow
7 mil
0.75" x 0.007" x 66'
ST43-075-66BK
20
100
Black
7 mil
0.75" x 0.007" x 66'
Panduit® PVC Tape Part Numbers
ST14 & ST17 General Purpose Tape
StrongHold ST14 & ST17 General Purpose PVC Electrical Tape is a 0.18
mm (7 mil), one sided rubber based, pressure sensitive adhesive glossy
finish vinyl electrical tape. The ST17 series product is non-corrosive
and has pressure-sensitive adhesive which eliminates the need for
heat, moisture and or other catalysts to affect the application. The high
elongation makes it easy to tear while having excellent conformability
properties. The product is UL and CSA Listed, flame retardant, as well as
cold resistant. ST14 & ST17 is suitable as an electrical insulation when
insulation when used for splicing up 600 Volts or 80°C (176°F).
ST15 General Purpose Tape
StrongHold ST15 General Purpose PVC Electrical Tape is a 0.13 mm
(5 mil), one sided coating of rubber based, pressure sensitive adhesive
matte finish vinyl electrical tape. The ST15 series product is noncorrosive and has pressure-sensitive adhesive which eliminates the need
for heat, moisture and or other catalysts to affect the application. The high
elongation makes it easy to tear while having excellent conformability
properties. The product is nonflammable. ST15 is suitable as an electrical
insulation when used for splicing up 600 Volts or 80°C (176°F).
General Purpose Electrical PVC Vinyl Tape Offering
Case
Qty
Minimum
Order Qty
Color
Thickness
Dimension
ST17-075-66BU
100
20
Blue
7 mil
0.75" x 0.007" x 66'
ST17-075-66BR
100
20
Brown
7 mil
0.75" x 0.007" x 66'
ST17-075-66GY
100
20
Gray
7 mil
0.75" x 0.007" x 66'
ST17-075-66GR
100
20
Green
7 mil
0.75" x 0.007" x 66'
ST17-075-66OR
100
20
Orange
7 mil
0.75" x 0.007" x 66'
ST17-075-66RD
100
20
Red
7 mil
0.75" x 0.007" x 66'
ST17-075-66YL
100
20
Violet
7 mil
0.75" x 0.007" x 66'
ST17-075-66VI
100
20
White
7 mil
0.75" x 0.007" x 66'
ST17-075-66WH
100
20
Yellow
7 mil
0.75" x 0.007" x 66'
ST14-075-60BK
100
20
100
20
7 mil
5 mil
0.75" x 0.007" x 66'
ST15-07566GRYL
Black
Yellow
with Green
Stripes
Part Number
C.5
Order number of pieces required, in multiples of Standard Package Quantity.
0.75" x 0.005" x 66'
Call 866-405-6654 or visit www.panduit.com/stronghold
C.6
Hazard Tape
Panduit offers an extensive assortment of blank and pre-printed
hazard tapes with varying legends, colors, and dimensions for
indoor and outdoor applications. Panduit Hazard Tapes feature
highly visible legends with resistance from abrasion, chemicals,
and UV light.
Panduit ® Hazard Tape Part Numbers
Underground Hazard Tapes
• Used to warn of buried utility lines
• HTU* parts are made of polyethylene tape
• Supplied in rolls of 1000 feet (30.5 meters)
Part Number
Legend
Color
(Legend/
Background)
Width
(In.)
Width
(mm)
Std.
Pkg.
Qty.
Polyethylene
HTU3G-T-M
CAUTION
TELEPHONE LINE
BURIED BELOW
Black/
Green
CAUTION FIBER
OPTIC CABLE
BURIED BELOW
Black/
Orange
HTU3O-T-M
CAUTION
TELEPHONE LINE
BURIED BELOW
Black/
Orange
HTU3R-E-M
CAUTION
ELECTRIC LINE
BURIED BELOW
Black/
Red
HTU3Y-E-M
CAUTION
ELECTRIC LINE
BURIED BELOW
Black/
Yellow
HTU60-TV
CAUTION CABLE
TV LINE BURIED
BELOW
Black/
Orange
HTU6R-E
CAUTION
ELECTRIC LINE
BURIED BELOW
Black/
Red
CAUTION BURIED
FIBER OPTIC
CABLE
Black/
Orange
HTU60-T
CAUTION
TELEPHONE LINE
BURIED BELOW
Black/
Orange
HTU6Y-E
CAUTION
ELECTRIC LINE
BURIED BELOW
Black/
Yellow
HTU6Y-G
CAUTION GAS
LINE BURIED
BELOW
Black/
Yellow
CAUTION
ELECTRIC LINE
BURIED BELOW
(English/French)
Black/
Yellow
HTU3O-FO-M
HTU6O-FO
76.2
3.00
1
152.4
6.00
French Legend
HTU3Y-EF
D.1
Order number of pieces required, in multiples of Standard Package Quantity.
3.00
76.2
Call 866-405-6654 or visit www.panduit.com/stronghold
1
D.2
Underground Hazard Tapes
™
StrongHold
Panduit ® Hazard
CableTape
Tie Part Numbers
Detectable Underground Hazard Tapes
Solid Color Adhesive Warning Tapes
• Used
• Used
to warn of buried utility lines
• HTU* parts are made of polyethylene tape
• Supplied in rolls of 1000 feet (30.5 meters)
Part Number
Legend
Color
(Legend/
Background)
Width
(In.)
Width
(mm)
Std.
Pkg.
Qty.
Laminated Detectable Aluminum
HTDU3B-W
CAUTION WATER
LINE BURIED
BELOW
Black/
Blue
CAUTION FIBER
SEWER LINE
BURIED BELOW
Black/
Green
HTDU30-FO
CAUTION FIBER
OPTIC CABLE
BURIED BELOW
Black/
Orange
HTDU3O-T
CAUTION
TELEPHONE LINE
BURIED BELOW
Black/
Orange
HTDU3R-E
CAUTION
ELECTRIC LINE
BURIED BELOW
Black/
Red
HTDU60-FO
CAUTION FIBER
OPTIC CABLE
BURIED BELOW
Black/
Orange
HTDU3G-S
to identify hazards, traffic lanes, etc.
• Installs faster and lasts longer than paint
• Durable vinyl continuous tape for indoor use
3.00
Part Number
Color
HT2-BLU
Blue
HT2-GRN
Green
HT2-ORN
Orange
HT2-RED
Red
HT2-YEL
Yellow
HT2-WHT
White
1
6.00
Color
HT2S-RED-WHT
Red/White
• Used to warn of temporary hazards
• Attaches easily to posts, walls, etc.
• Highly visible 2.00" (51.0mm) black legends
• Made of non-adhesive polyethylene film
• Supplied in rolls of 1000 feet (30.5 meters)
HT3S-BLK-YEL
Black/Yellow
HT3S-RED-WHT
Red/White
D.3
HTB3-DNE-M
CAUTION
DO NOT ENTER
HTB3-HV-M
CAUTION
HIGH VOLTAGE
2.00
50.8
180.00
55.0
1
Roll
Length
(Ft.)
Roll
Length
(m)
Std.
Pkg.
Qty.
54.00
16.5
1
Width
(In.)
Width
(mm)
2.00
50.8
3.00
76.2
on yellow background
Color
(Legend/
Background)
Black/
Yellow
Std.
Pkg.
Qty.
152.4
Barricade Tapes
Legend
Roll
Length
(m)
• Self-adhesive striped warning/hazard tape
• Color coded for quick indentification
• Can be used in place of paint
• Durable vinyl continuous tape for indoor use
Black/Yellow
CAUTION
Roll
Length
(Ft.)
Striped Hazard Tapes
HT2S-BLK-YEL
HTB3-C-M
Width
(mm)
76.2
Part Number
Part Number
Width
(In.)
Width
(In.)
Width
(mm)
Std.
Pkg.
Qty.
3.00
76.2
1
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
D.4
Terminals
StrongHold ™ Terminal Part Numbers
StrongHold offers a vast variety of contractor grade terminals,
disconnects, and splices with multiple sizes and insulation options.
Contractor grade terminals are reliable and economical options that
withstand a wide range of general purpose applications.
Ring Terminal
American Wire Gauge
Circular Mil
Male Disconnect
Nylon Insulated
Quick Connect Tab
EDNF18-187MB-Q
Max Temperature
PIN Diagram
Strip Length
25 pc
15_piggy
back disconnects_vinyl
01_ring terminal_na
bullet
_vinyl
04_fork terminal
insulated_vinyl
disconnects_nylon
Male
Bullet
Ring
Terminal
ring terminal_vinyl
locking fork terminal_na
E.1
25
EV6-56R-Q
#6
Blue
5/16"
25
EV8-8R-Q
#8
Red
#8
25
EV8-12R-Q
#8
Red
1/2
25
EV8-14R-Q
#8
Red
1/4"
25
EV8-38R-Q
#8
Red
3/8"
25
EV8-56R-Q
#8
Yellow
5/16"
25
EV10-10RB-Q
#12-10
Yellow
#10
25
EV10-12RB-Q
#12-10
Yellow
1/2"
25
25
.145"
3.7mm
INSUL. DIA.
MAX
EV10-38RB-Q
#12-10
Yellow
3/8"
25
EV10-56RB-Q
#12-10
Yellow
5/16"
25
EV10-6RB-Q
#12-10
Yellow
#6
25
EV10-8RB-Q
#12-10
Yellow
#8
25
EV14-10RB-Q*
#16-14
Blue
#10
25
EV14-14RB-Q*
#16-14
Blue
1/4"
25
EV14-38RB-Q
#16-14
Blue
3/8
25
EV14-56RB-Q*
#16-14
Blue
5/16"
25
EV14-6RB-Q*
#16-14
Blue
#6
25
EV14-8RB-Q*
#16-14
Blue
#8
25
EV18-8RB-Q*
#22-18
Red
#8
25
EV18-10RB-Q*
#22-18
Red
#10
25
EV18-14RB-Q*
#22-18
Red
1/4"
25
EV18-56RB-Q*
#22-18
Red
5/16"
25
EV18-6RB-Q*019_male 019_male
#22-18
bullet disconnects_vinyl
bullet disconnects_vinyl
Red
#6
25
Made in Taiwan
6
13056
34228
6
See Panduit.com for individual part compliance
and tooling options. All parts are ROHS compliant.
019_male bullet disconnects_vinyl
019_male
bullet disconnects_vinyl
020_butt slice_na
021_butt
splice_vinyl
020_butt
slice_na
010_female
disconnect _na
06_locking fork terminal_vinyl
07_narrow
_vinyl
08_female
disconnect_na
09_female
disconnect_na
03_fork terminal_na
019_male fork
bullet
disconnects_vinyl
04_fork
terminal insulated_vinyl
05_locking fork terminal
020_butt
slice_na
021_butt
splice_vinyl
non-insulated
Narrow Fork
Terminal
022_step-down splice_vinyl
splice_vinyl
021_butt022_step-down
splice_vinyl
Locking Fork
Terminal
023_quick
023_quicksplice_vinyl
splice_vinyl
terminal_vinylDown
07_narrow fork _vinyl
Butt Splice 06_locking forkStep
Splice
011_female disconnect_vinyl
024_Pin
Terminal_vinyl
024_Pin
Terminal_vinyl
022_step-down splice_vinyl
023_quick
013_male splice_vinyl
disconnects_nylon
08_female disconnect_na
09_female disconnect_na
Quick
Splice
024_Pin Terminal_vinyl
024_Pin Terminal_vinyl
022_step-down
022_step-down
splice_vinyl
splice_vinyl 023_quick023_quick
splice_vinyl
splice_vinyl
021_butt splice_vinyl
016_female
bullet15_piggy back disconnects_vinyl
017_female bullet
back
disconnects_vinyl
013_male disconnects_nylon
014_male
disconnects_nylon
disconnects_vinyl 014_male 15_piggy
disconnects_vinyl
011_female disconnect_vinyl
012_males013_male
disconnect_na
disconnects_nylon
disconnects_vinyl
Female
Disconnect
Male
Disconnect
016_female bullet 15_piggy back
016_female
017_female
bullet
bullet
disconnects_vinyl
014_male disconnects_vinyl
Pin
Terminal
Blade
disconnects_nylon
disconnects_nylon
disconnects_vinyl
Terminal
024_Pin Terminal_vinyl
025_Blade025_Blade
Terminal_vinyl
Terminal_vinyl
Piggy Back
Disconnect
Female Bullet
bullet
Wire Joint 018_male
disconnects_nylon
026_Wire
Joint_vinyl
026_Wire
017_female
018_male
bullet Joint_vinyl
bullet
disconnects_vinyl
disconnects_nylon
027_wire nuts
027_wire
with spring_vinyl
nuts with spring_vinyl
locking fork terminal_vinyl
Call 866-405-6654 or visit www.panduit.com/stronghold E.2
Order number of pieces required, in multiples of Standard Package Quantity.
025_Blade Terminal_vinyl
022_step-down splice_vinyl
07_narrow fork _vinyl
010_female disconnect _na
020_butt slice_na
020_butt slice_na
021_butt splice_vinyl
021_butt splice_vinyl
010_female disconnect _na 010_female
disconnectdisconnect_vinyl
_na
013_male disconnects_nylon
014_male disconnects_vinyl
011_female
011_female
012_males
disconnect_vinyl
disconnect_na
012_males disconnect_na
terminal_na 05_locking fork terminal
04_fork terminal 01_ring
insulated_vinyl
02_ring terminal_vinyl06_locking fork terminal_vinyl
03_fork terminal_na
non-insulated
019_male
020_butt slice_na
018_male
bullet bullet disconnects_vinyl
05_locking fork terminal
non-insulated
3/8"
221°F
105°C
MAX
* -Q= Package quantity of 25
-L= Package quantity of 50 where applicable
Fork
Terminal
Blue
9/32"
6.8mm
Please note the following information
regarding bag02_ring
quantities:
terminal_vinyl
03_fork terminal_na
fork terminal_na
#6
1/4"
01_ring terminal_na
02_ring terminal_vinyl
25
EV6-38R-Q
Yellow
Available in insulated and non-insulated options. See insulation options
throughout this booklet for detailed information per product.
sconnects_vinyl
25
1/2"
#12-10
Terminals Legend
012_males disconnect_na
#10
Blue
EV10-14RB-Q
Tab Size
disconnect_vinyl
Blue
#6
.187"X.032"
4.8 x 0.8mm
TAB SIZE
Acceptable for Internal Wiring of Equipment
Bullet
#6
EV6-12R-Q
300V
MAX
Voltage
Tool
EV6-10R-Q
22-16 STR CU
0.5-1.5 mm²
KST2000C
Stud Size
Stud/
Std.Pkg.
Tab Size
Qty.
Color
Ring Terminal, Insulated – Vinyl
Navigating the StrongHold Packaging Icons
Insulation Diagram
Wire
Range (AWG)
Part Number
023_quick splice_vinyl
08_female disconnect_na
024_Pin Terminal_vinyl
025_Blade Terminal_vinyl
09_female disconnect_na
026_Wire Joint_vinyl
026_Wire Joint_vinyl
027_wire nuts with spring_vinyl
027_wire
nutsTerminal_vinyl
with spring_vinyl
025_Blade
026_Wire
Joint_vinyl
016_female
bullet
disconnects_nylon
027_wire
nuts
with spring_vinyl
017_female
bullet
disconnects_vinyl
018_male bullet
disconnects_nylon
012_males disco
15_piggy back d
018_male bullet
disconnects_nylo
01_ring terminal_na
02_ring terminal_vinyl
Terminals
StrongHold ™ Terminals Part Numbers
Ring Terminal
Part Number
Narrow Fork Terminal
Wire
Range (AWG)
Color
Stud/
Std.Pkg.
Tab Size
Qty.
05_locking fork terminal
Part Number
non-insulated
04_fork terminal insulated_vinyl
E10-10RB-Q
#12-10
Yellow
#10
25
E10-14RB-Q
#12-10
Yellow
1/4"
25
E10-6RB-Q
#12-10
Yellow
#6
25
E10-8RB-Q
#12-10
Yellow
#8
25
Blue
#10
25
#16-14
Blue
#4
25
E14-6RB-Q*
#16-14
Blue
#6
25
E14-8RB-Q*
#16-14
Blue
#8
25
E14-10RB-Q*
02_ring terminal_vinyl
E14-4RB-Q*
#16-14
03_fork terminal_na
E18-10RB-Q*
#22-18
Red
E18-4RB-Q*
#22-18
E18-6RB-Q*
#22-18
#22-18
E18-8RB-Q*
04_fork terminal insulated_vinyl
05_locking fork terminal
non-insulated
01_ring terminal_na
#10
25
Red
#4
25
Red
#6
25
Red
#8
25
07_narrow fork _vinyl
02_ring terminal_vinyl
Part Number
Color
Stud/
Std.Pkg.
Tab Size
Qty.
04_fork terminal insulated_vinyl
Fork Terminal, Insulated – Vinyl
07_narrow fork _vinyl
#10
25
Yellow
#8
25
EV14-10FNB-Q
#16-14
Blue
#10
25
EV14-6FNB-Q
#16-14
Blue
#6
25
Blue
#8
25
Color
Stud/
Std.Pkg.
Tab Size
Qty.
09_female disconnect_na
#16-14
Locking Fork Terminal
02_ring terminal_vinyl
Part Number
03_fork terminal_na
Wire
Range (AWG)
Locking Fork Terminal, Insulated – Vinyl
05_locking fork terminal
non-insulated
EV10-10LFB-Q
#12-10
Yellow
#10
25
EV10-14LFB-Q
#12-10
Yellow
1/4"
25
EV10-6LFB-Q
#12-10
Yellow
#6
25
EV10-8LFB-Q
#12-10
Yellow
#8
25
EV14-10LFB-Q*
#16-14
Blue
#10
25
EV14-6LFB-Q*
#16-14
Blue
#6
25
06_locking fork terminal_vinyl
Yellow
#10
25
EV14-8LFB-Q*
#16-14
Blue
#8
25
EV10-14FB-Q
#12-10
Yellow
1/4"
25
EV18-10LFB-Q*
#22-18
Red
#10
25
#12-10
Yellow
5/16"
25
EV18-6LFB-Q*
03_fork terminal_na
#22-18
Red
#6
25
EV10-6FB-Q
#12-10
Yellow
#6
25
EV18-8LFB-Q*
#22-18
Red
#8
25
EV10-8FB-Q
#12-10
Yellow
#8
25
Locking Fork Terminal, Non-Insulated
non-insulated
EV14-10FB-Q*
#16-14
Blue
07_narrow fork _vinyl
#10
25
E10-10LFB-Q
#12-10
Yellow
#10
25
EV14-14FB-Q
#16-14
Blue
1/4"
25
E10-14LFB-Q
#12-10
Yellow
1/4"
25
EV14-6FB-Q*
#16-14
Blue
#6
25
E10-6LFB-Q
#12-10
Yellow
#6
25
EV14-8FB-Q*
#16-14
Blue
#8
25
E10-8LFB-Q
#12-10
Yellow
#8
25
EV18-10FB-Q*
#22-18
Red
#10
25
#16-14
Blue
#10
25
EV18-6FB-Q*
#22-18
Red
06_locking fork terminal_vinyl
E14-10LFB-Q*
#6
25
#16-14
Blue
#6
25
#22-18
Red
E14-6LFB-Q*
#8
25
Red
25
#16-14
Blue
1/4"
E14-8LFB-Q*
#8
25
E18-10LFB-Q*
#22-18
Red
#10
25
E18-6LFB-Q*
#22-18
Red
#6
25
E18-8LFB-Q*
#22-18
Red
#8
25
08_female disconnect_na
EV10-56FB-Q
05_locking fork terminal
08_female disconnect_na
EV18-14FB-Q
09_female disconnect_na
06_locking fork terminal_vinyl
09_female disconnect_na
#22-16
01_ring terminal_na
08_female disconnect_na
04_fork terminal insulated_vinyl
02_ring terminal_vinyl
09_female disconnect_na
05_locking fork terminal
non-insulated
Fork Terminal, Non-Insulated
E.3
Yellow
#12-10
#12-10
EV18-8FB-Q*
fork terminal_na
#12-10
EV10-10FB-Q
04_fork terminal insulated_vinyl
07_narrow fork _vinyl
Stud/
Std.Pkg.
Tab Size
Qty.
EV10-8FNB-Q
08_female disconnect_na
06_locking fork terminal_vinyl
Wire
03_fork terminal_na
Range (AWG)
Color
EV10-10FNB-Q
EV14-8FNB-Q
Fork Terminal
01_ring terminal_na
Wire
Range (AWG)
06_locking fork terminal_vinyl
Narrow Fork Terminal, Insulated – Vinyl
Ring Terminal, Non-Insulated
01_ring terminal_na
03_fork terminal_na
E10-10FB-Q
#12-10
Yellow
#10
25
E10-14FB-Q
#12-10
Yellow
1/4"
25
E10-6FB-Q
#12-10
Yellow
#6
25
E10-8FB-Q
#12-10
Yellow
#8
25
E14-10FB-Q*
#16-14
Blue
#10
25
E14-6FB-Q*
#16-14
Blue
#6
25
Female Disconnect Terminal, Insulated – Nylon
E14-8FB-Q*
#16-14
Blue
#8
25
EDNF10-250FI-Q
#12-10
#16-14
Blue
0.187" x 0.020"
25
#16-14
Blue
0.250" x 0.032"
25
female disconnect_fully vinyl
EDNF18-188FIB-Q*
female disconnect_fully nylon #22-18
Red
0.187" x 0.020"
25
EDNF18-250FIB-Q*
Red
0.250" x 0.032"
25
Female Disconnect Terminal
07_narrow fork _vinyl
08_female disconnect_na
09_female disconnect_na
Part Number
E18-10FB-Q*
#22-18
Red
#10
25
EDNF14-188FIB-Q*
E18-6FB-Q*
#22-18
Red
#6
25
EDNF14-250FIB-Q*
E18-8FB-Q*
#22-18
Red
#8
25 female disconnect_vinyl
Order number of pieces required, in multiples of Standard Package Quantity.
locking fork terminal_vinyl
Wire
Range (AWG)
#22-18
Color
Stud/
Std.Pkg.
Tab Size
Qty.
Yellow 0.250" x 0.032"
Call 866-405-6654 or visit www.panduit.com/stronghold
25
E.4
ring terminal_vinyl
Terminals
fork terminal_na
Female Disconnect Terminal
Wire
Range (AWG)
Part Number
010_female disconnect _na
011_female disconnect_vinyl
Stud/
Std.Pkg.
Tab Size
Qty.
Color
StrongHold ™ Terminals Part Numbers
Piggy Back Disconnect Terminal
012_males disconnect_na
Female Disconnect Terminal, Insulated – Vinyl
#12-10
EDV14-188B-Q*
#16-14
Blue
0.187" x 0.020"
25
EDV14-250B-Q*
#16-14
Blue
0.250" x 0.032"
25
EDV18-188B-Q*
#22-18
Red
013_male
disconnects_nylon25
0.187"
x 0.020"
012_males disconnect_na
EDV18-250B-Q*
#22-18
Red
0.250" x 0.032"
25
EDV10-250FIB-Q
#12-10
Yellow 0.250" x 0.032"
25
EDV14-250FIB-Q
#16-14
Blue
0.250" x 0.032"
25
EDV18-250FIB-Q
#22-16
Red
0.250" x 0.032"
25
locking fork terminal_vinyl
n
n
onnect_vinyl
nnects_vinyl
011_female disconnect_vinyl
25
0.187" x 0.020"
Blue
disconnects_nylon
disconnects_vinyl
0.250"
x 0.032" male bullet
25 disconnect_vinyl
ED18-188-Q*
#22-18
Red
0.187" x 0.020"
25
ED18-250-Q*
#22-18
Red
0.250" x 0.032"
25
017_female bullet
Male Disconnect Terminal
010_female disconnect _na
011_female disconnect_vinyl
Part Number
Wire
Range (AWG)
012_males disconnect_na
Stud/
Std.Pkg.
Tab Size
Qty.
Color
016_female bullet
disconnects_nylon
EDNF14-187MB-Q
#16-14
Blue
0.187" x 0.032"
25
EDNF18-187MB-Q
#22-16
Red
0.187" x 0.032"
25
EDNF10250FIMB-Q
#12-10
EDNF14250FIMB-Q*
012_males
disconnect_na
014_male disconnects_vinyl
011_female
disconnect_vinyl
013_male disconnects_nylon
EDNF18250FIMB-Q*
Yellow 0.250" x 0.032"
Blue
#16-14
15_piggy back disconnects_vinyl
#22-18
0.250" x 0.032"
step-down splice_vinyl
EDV14-187MB-Q
#16-14
Blue
0.187" x 0.032"
25
#16-14
Blue
0.250" x 0.032"
25
#22-16
Red
0.187" x 0.032"
25
#22-18
Red
0.250" x 0.032"
disconnects_vinyl
EDV18-250M-Q*
018_male bullet
disconnects_nylon
ED14-250MB-Q*
012_males disconnect_na
017_female bullet
disconnects_vinyl
ED18-250MB-Q*
#12-10
#16-14
#22-18
Bullet
Std.Pkg.
Qty.
.156" / 3.9mm
25
EBNF18-4FIB-Q
#22-16
Red
.156" / 3.9mm
25
Red
.156" / 3.9mm
25
Blue
.156" / 3.9mm
25
male bullet_fully nylon
Female Bullet Terminal, Insulated – Vinyl
017_female bullet
disconnects_vinyl
EBV18-4B-Q
#22-16
EBV14-4B-Q
#16-14
018_male bullet
disconnects_nylon
Male Bullet Terminal
Part Number
Wire
Range (AWG)
Color
Bullet
Std.Pkg.
Qty.
butt slice_na
EBNF14-4FIM-Qbutt splice_vinyl #16-14
Blue
.156" / 3.9mm
25
EBNF18-4FIM-Q
Red
.156" / 3.9mm
25
#16-14
Blue
.156" / 3.9mm
25
#22-16
Red
.156" / 3.9mm
25
#22-16
male bullet_fully nylon
Male Bullet Terminal, Insulated – Vinyl
25
EBV18-4MB-Q
019_male bullet disconnects_vinyl
020_butt slice_na
021_butt splice_vinyl
Butt Splice
blade
25 terminal_vinyl
Part Number
pin terminal_vinyl
Wire
Range (AWG)
Color
Std.Pkg.
Qty.
Butt Splice, Insulated – Vinyl
Yellow 0.250" x 0.032"
step-down splice_vinyl
Blue
Red
0.250" x 0.032"
25
butt slice_na
25
0.250"019_male
x 0.032"
25
bullet disconnects_vinyl
butt splice_vinyl
ESV10BX-Q
#12-10
Yellow
25
ESV14BX-Q*
#16-14
Blue
25
#22-18
Red
25
022_step-down splice_vinyl
023_quick splice_vinyl
ESV18BX-Q*
020_butt slice_na
024_Pin Terminal_vinyl
021_butt splice_vinyl
Butt Splice, Non-Insulated
018_male bullet
disconnects_nylon
15_piggy back disconnects_vinyl
E.5
Color
018_male bullet
Male Disconnect Terminal, Non-Insulated
ED10-250M-Q
25
Blue
EBV14-4MB-Q
#12-10
EDV18-187MB-Q
15_piggy
back
disconnects_vinyl
017_female
bullet
0.250" x 0.032"
#16-14
disconnects_nylon
female
bullet_full vinyl
25
EDV10-250M-Q
EDV14-250M-Q*
#22-18
EBNF14-4FIB-Q
15_piggy back disconnects_vinyl
014_male disconnects_vinyl
Male Disconnect Terminal, Insulated – Vinyl
014_male
disconnects_vinyl
016_female
bullet
disconnects_nylon
25
Red
25
0.250" x 0.032" female
25 bullet_full vinyl
Yellow 0.250" x 0.032"
0.250" x 0.032"
Male Bullet Terminal, Insulated – Nylon
male bullet disconnect_vinyl
Red
25
Blue
Wire
Range (AWG)
Part Number
Male Disconnect
Terminal, Insulated – Nylon
018_male bullet
disconnects_nylon
Yellow 0.250" x 0.032"
#16-14
Female Bullet Terminal
25
016_female bullet
#12-10
Female Bullet Terminal, Insulated – Nylon
Blue
female disconnect_nylon
Stud/
Std.Pkg.
Tab Size
Qty.
15_piggy back disconnects_vinyl
#16-14
female disconnect_na
011_female disconnect_vinylEDV14-250P-Q*
012_males disconnect_na
EDV18-250P-Q*
014_male disconnects_vinyl
#16-14
15_piggy back disconnects_vinyl
014_male disconnects_vinylED14-250-Q*
017_female bullet
disconnects_vinyl
EDV10-250P-Q
010_female disconnect _na
013_male disconnects_nylon
Female Disconnect Terminal, Non-Insulated
ED14-188-Q*
Color
Piggy Back Disconnect Terminal, Insulated – Vinyl
Yellow 0.250" x 0.032"
EDV10-250-Q
locking fork terminal_na
Wire
Range (AWG)
Part Number
019_male bullet disconnects_vinyl
022_step-down splice_vinyl
Order number of pieces required, in multiples of Standard Package Quantity.
blade terminal_vinyl
023_quick splice_vinyl
pin terminal_vinyl
ES10B-Q
#12-10
Yellow
25
ES14B-Q*
#16-14
Blue
25
ES18B-Q*
#22-18
Red
25
020_butt slice_na
021_butt splice_vinyl
025_Blade Terminal_vinyl
026_Wire Joint_vinyl
024_Pin Terminal_vinyl
027_wire nuts with spring_vinyl
Call 866-405-6654 or visit www.panduit.com/stronghold
E.6
Terminals
Step Down Splice
_vinyl
020_butt slice_na
Part Number
019_male bullet disconnects_vinyl
Blade Terminal
022_step-down splice_vinyl
Wire
Range (AWG)
Color
021_butt splice_vinyl
Std.Pkg.
Qty.
019_male bullet disconnects_vinyl
ESV10-ESV14-Q
25
#12-10 to 22-18, Yellow
Yellow
with Red Color Ring
25
#16-14 to 22-18, Blue
024_Pin
Terminal_vinyl
with Red
Color
Ring
Blue
25
ESV6-ESV8-Q
#6 to 8, Blue with Red
Color Ring
Blue
25
ESV8-ESV10-Q
#8 to 12-10, Red with
Yellow Color Ring
Red
25
ESV8-ESV14-Q
#8 to 16-14, Red with
Blue Color Ring
Red
25
ESV14-ESV18-Q
022_step-down splice_vinyl
023_quick splice_vinyl
Quick Splice
025_Blade Terminal_vinyl
020_butt slice_na
026_Wire Joint_vinyl
Part Number
021_butt splice_vinyl
025_Blade Terminal_vinyl
022_step-down splice_vinyl
Color
Std.Pkg.
Qty.
Red
25
Blue
25
Brown
25
EQSP10-Q
#12-10
Yellow
25
#16-14
Blue
25
#22-18
Red
25
Color
Std.Pkg.
Qty.
#22-14
Clear
25
#18 -12
Clear
25
#16-8
Clear
25
EDV18-87MB-Q
026_Wire Joint_vinyl
#12-10
Yellow
25
EQSP14-Q
#18-14
Blue
25
EQSP18-Q
#22-18
Red
25
027_wire nuts with spring_vinyl
Wire Joint
024_Pin Terminal_vinyl
Part Number
Wire
Range (AWG)
026_Wire Joint_vinyl
EJN314-412-Q
027_wire nuts with spring_vinyl
Please note the following information regarding bag quantities:
* -Q= Package quantity of 25
-L= Package quantity of 50 where applicable
See Panduit.com for individual part compliance and tooling options.
All parts are ROHS compliant.
024_Pin Terminal_vinyl
023_quick splice_vinyl
026_Wire Joint_vinyl
Std.Pkg.
Qty.
EDV14-87MB-Q
EJN418-212-Q
025_Blade Terminal_vinyl
#18-14
EQSP10-18D-Q
Color
EDV10-11MB-Q
EJN218-216-Q*
#12-10 to 18-14
EQSP14D-Q*
021_butt splice_vinyl
#22-16
Wire
Range (AWG)
Wire Joint, Insulated – Nylon
Quick Splice, Insulated – Polypropylene
EQSP18D-Q
023_quick splice_vinyl
027_wire nuts with spring_vinyl
Wire
Range (AWG)
021_butt splice_vinyl
024_Pin Terminal_vinyl
Blade Terminal, Insulated – Vinyl
#12-10 to 16-14, Yellow
Yellow
with Blue Color Ring
ESV10-ESV18-Q
023_quick splice_vinyl
Part Number
020_butt slice_na
Step Down Splice, Insulated – Vinyl
connects_vinyl
ce_vinyl
StrongHold ™ Terminals Part Numbers
Pin Terminal
027_wire nuts with spring_vinyl
Part Number
Wire
Range (AWG)
Color
Pin
Std.Pkg.
Diameter Qty.
Pin Terminal, Insulated – Vinyl
024_Pin Terminal_vinyl
EV10-P55-Q
#12-10
Yellow
0.10" Dia.
25
EV14-P47B-Q*
#16-14
Blue
0.07" Dia.
25
EV18-P47B-Q*
#22-18
Red
0.07" Dia.
25
027_wire nuts with spring_vinyl
E.7
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
E.8
Grounding Pigtails
StrongHold ™ Grounding Pigtail Part Numbers
Grounding Pigtails
StrongHold offers an assortment of grounding pigtails, power tails,
and hardware in a variety of configurations and lengths that meet
a broad range of applications, increasing jobsite productivity and
reliability.
Navigating the StrongHold™ Packaging Icons
12 Solid
SOLID
AWG
SOLID
12 Solid
Stranded
STRANDED
Grounding Bonding Pigtail
AWG
10" 254mm Total Length
STRANDED
12 Stranded
AWG
SGPL12-10S-L
16mm (16mm) Strip Length
5/8"
Strip Length
5/8"
12
1"25mm
(25mm) Strip Length
Strip Length
1"
AWG
#10-32 UNC Thread
#10-32
UNC
THREAD
50 pc
SOLID
1"
25mm
Strip Length
#10-32
UNC
THREAD
PHILIPS
DRIVE
FLAT
DRIVE
1/8"
3.2mm
SQUARE
DRIVE
#10-32 UNC Thread
#10-32
UNC
THREAD
PHILIPS
Philips
Drive
DRIVE
Made in USA
E136227
GROUNDING AND BONDING EQUIPMENT
Flat Drive
FLAT
DRIVE
1/8"
3.2mm
1/8"
(3.2mm) Square Drive
SQUARE
DRIVE
Grounding Pigtails Legend
Part Number
Wire
Type
SGPL12-7S-L
Strip
Length
12 AWG
6.5"
One
1"
Solid
25mm
SGPL12-8S-L
12 AWG
8"
One
1"
Solid
25mm
SGPL12-10S-L
12 AWG
10"
One
1"
Solid
25mm
SGPL12-12S-L
12 AWG
12"
One
1"
Solid
25mm
SGPL14-8S-L
14 AWG
8"
One
1"
Solid
25mm
SGPS12-8SRF-L
12 AWG
8"
One
N/A
Stranded
SGPS12-8SRT-L
12 AWG
8"
One
5/8"
Stranded
16mm
SGPS12-8FT-L
12 AWG
8"
One
5/8"
Stranded
16mm
SGPSL12-8SFT-Q 12 AWG
8"
Two
1"
Solid &
25mm
Stranded
SGPSS12-8SFT-Q 12 AWG
8"
Two
5/8"
Stranded
16mm
SGPSS12-8SFF-Q 12 AWG
8"
Two
N/A
Stranded
SGPSSL12-8S-Q
12 AWG
8"
Three
1"
Solid &
25mm
Stranded
SGPSSS12-8S-Q
12 AWG
8"
Three
5/8"
Stranded
16mm
UL Recognized Processed Wires
SGPS12-8FT-L10 12 AWG
8"
One
5/8"
Stranded
16mm
SGPS12-8FT-L20 12 AWG
8"
One
5/8"
Stranded
16mm
Grounding Screws
GSC10-32-38-C
N/A
3/8"
N/A
N/A
Thread Forming
Available in various Insulated Stranded Wires and Single and Dual-Gang
Number
Overall
of
Length Wires
Wire
Insulation
Color/Part
Color
Std.
Pkg.
Qty.
Green
50
Green
50
Green
50
Green
50
Green
50
Green
50
Green
50
Green
50
Green
25
Green
25
Green
25
Green
25
Green
25
White
50
Black
50
Green
100
GSH10-32-38-C
N/A
3/8"
N/A
N/A
Green
100
Note:
1. All the screws/terminals are compatible with #10-32 thread.
2. All the Processed Wires have Voltage rating of 600 V at 105 °C.
3. All the screws are compatible with Flat, Philips and 1/8" (3.2mm) Square Drive.
Power Tails intended for use connecting up to 600 volt power
GSH/GSC
Ground Screws
Flanged Spade Terminal
and GSC Ground Screw
F.1
Flanged Spade
Terminal
Ring Terminal and
GSH Ground Screw
Order number of pieces required, in multiples of Standard Package Quantity.
Single Gang with
One Stranded Wire
Dual Gang with
One Solid Wire
Dual Gang
Dual Gang with
One Stranded Wire
Call 866-405-6654 or visit www.panduit.com/stronghold
F.2
Stainless Steel
Cable
Ties Books
Wire Marker
StrongHold Marker Books features an assortment of conveniently
pocket-sized pre-printed and self-laminating write-on marker book
solutions used to identify many electrical and network components
in markets such as Electrical, Industrial, Electronic, and Network.
Marker books come in a variety of legends or ink receptive material
for customization.
StrongHold ™ Wire Marker Part Numbers
Pre-Printed Marker Books
• Convenient, pocket-sized book
•
Markers are perforated and can
be torn in half to mark both ends of
conductors
• Terminal block markers are included to properly identify connectors
• Ten pages of markers per book
• Temperature range: -40°F to 170°F (-40°C to 77°C)
Part Number
Legend
Total
Markers
Each Legend
PCMB-1
0 thru 9
45
PCMB-2
A thru Z, 0 thru 15, +, -, /
10
PCMB-3
1 thru 45
10
PCMB-4
1, 2, 3
150
PCMB-5
A, B, C
150
PCMB-6
T1, T2, T3
150
PCMB-7
L1, L2, L3
150
PCMB-8
1 thru 15
16 thru 90
A thru Z, +, -, /, 0
6
4
2
PCMB-9
1, 2, 3, A, B, C
L1, L2, L3, T1, T2, T3
45
30
PCMB-11
1 thru 30
15
PCMB-12
A thru Z
+
Blank (write-on)
15
8
7
21
PCMB-13
+, -, AC, DC
POS, NEG, GND NEUT
SPARE, Blank (write-on)
45
21
21
21
PCMB-14
46 thru 90
0, +, 1 thru 45
0 thru 33, A, B, C, +, -,
L1, L2, L3, T1, T2, T3
0 thru 9
L1, L2, L3, T1, T2, T3
10
PCMB-15
PCMB-16
PCMB-25
Legend: Black
Marker sizes:
Std.
Ctn.
Qty.
Min.
Order
Qty.
Book(s)
10
10
15
10
10
45
15
Background: White
Full size marker – 0.22" x 1.38" (5.60mm x 34.90mm).
Maximum wire O.D., 0.38" (9.50mm).
Half size marker – 0.22" x 0.69" (5.60mm x 17.40mm).
Maximum wire O.D., 0.19" (4.70mm).
Terminal block marker – 0.22" x 0.25" (5.60mm x 6.30mm).
G.1
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
G.2
Cable
Wire Marker
Ties Books
StrongHold™ Electrical/Network
Supports and Fasteners
Blank Self-Laminating Write-On Cable Marker Books
• 10 pages of markers per book
• Clear section of marker over laminates and protects printed legend
• Markers have ink receptive area to allow handwritten legends
Part Number
Print-on
Area
(In.)
In.
mm
In.
mm
PSCB-12Y
0.62
0.50
12.7
1.50
38.1
180
PSCB-13Y
0.75
1.50
38.1
3.00
76.2
40
PSCB-16Y
1.00
1.50
38.1
6.00
152.4
20
PSCB-3Y
0.75
1.00
25.4
3.00
76.2
60
PSCB-3YELY*
0.75
1.00
25.4
3.00
76.2
60
PSCB-5Y
1.00
1.00
25.4
5.00
127.0
30
PSCB-6Y
1.00
1.00
25.4
6.00
152.4
30
Width
Length
™
Supports
and
StrongHold
Cable
Tie Fasteners
Part Numbers
StrongHold offers a complete line of supports and fasteners for the
commercial and industrial construction market, providing customers
everything they need to fix, route, secure, and manage power and
communication cabling.
Markers
Std
Std
Per
Pkg.
Ctn.
Book
Book(s) Book(s)
1
10
*Yellow
G.3
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
G.4
Supports & Fasteners
Cable/Conduit
StrongHold ™ Cable/Conduit Part Numbers
Push-Fit Conduit Clips
Snap-Close Conduit Clips
• No fastener required to retain conduit
• Static load capacity:
- 100 lbs. in vertical position
- 25 lbs. in horizontal position
• No fastener required to retain conduit
• Static load capacity:
- 25 lbs. in vertical position
- 15 lbs. in horizontal position
• Available with 1/4" non-threaded
mounting hole
Image 1
Fits EMT
(In.)
Part Number
Image 2
Image
No.
Fits EMT/
Rigid/IMC
(In.)
P6M
1
3/8*
100
P16M
1
1
100
P20M
1
1 1/4
P24M
1
1 1/2
Part Number
Mounting Hole
(In.)
1/4
non-threaded
Std.
Pkg.
Qty.
P8P
1/2
–
100
P12P
3/4
1/2
100
P16P
1
3/4
100
Std.
Pkg.
Qty.
100
100
P812M
1
1/2 – 3/4
P812M4I**
2
1/2 – 3/4
1/4-20 threaded
100
P32M
1
2
1/4
non-threaded
100
Conduit Clamps with Bolt
• Conduit hanger available for 1/2" – 4" conduit
• Bolt and nut (Phillips/flathead) provide
positive securing feature
• Available with threaded and non-threaded
mounting hole
100
*Or 14-2 through 12-3 MC/AC cable.
**Not UL or cUL listed.
H.1
Fits Rigid/IMC
(In.)
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
Fits
EMT
(In.)
Fits Rigid/IMC
(In.)
Mounting Hole
(In.)
Std.
Pkg.
Qty.
PCD0B
1/2
3/8 – 1/2
1/4 non-threaded
100
PCD1B
3/4
3/4
1/4 non-threaded
100
PCD2B
1
1
1/4 non-threaded
100
PCD2.5B
1 1/4
—
1/4 non-threaded
100
PCD3B
1 1/2
1 1/4
1/4 non-threaded
100
PCD4B
—
1 1/2
5/16 non-threaded
100
PCD5B
2
2
5/16 non-threaded
50
PCD6B
2 1/2
2 1/2
5/16 non-threaded
50
PCD7B
3
3
5/16 non-threaded
25
PCD8B
3 1/2
3 1/2
5/16 non-threaded
25
PCD9B
4
4
1/2 non-threaded
10
Call 866-405-6654 or visit www.panduit.com/stronghold
H.2
Supports & Fasteners
Cable/Conduit
Snap-Close Conduit Clips with Beam Clamps – Bottom Mount
StrongHold ™ Cable/Conduit Part Numbers
Snap-Close Conduit Clips with Beam Clamps – Side Mount
• Suspend conduit from bottom of beam
• Will pivot 360°
• Hammer-on installation
• Static load capacity: 75 lbs. vertically
Flange Thickness
(In.)
Fits
EMT/Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P6M24
1/8 – 1/4
3/8
100
P6M58
5/16 – 1/2
3/8
100
Part Number
P6M912
9/16 – 3/4
3/8
100
P812M24
1/8 – 1/4
1/2 – 3/4
100
Part Number
P812M58
P812M912
5/16 – 1/2
9/16 – 3/4
1/2 – 3/4
1/2 – 3/4
Flange Thickness
(In.)
Fits
EMT/Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P6M24SM
1/8 – 1/4
3/8
100
P6M58SM
5/16 – 1/2
3/8
100
100
P6M912SM
9/16 – 3/4
3/8
100
100
P812M24SM
1/8 – 1/4
1/2 – 3/4
100
5/16 – 1/2
1/2 – 3/4
100
P16M24
1/8 – 1/4
1
100
P812M58SM
P16M58
5/16 – 1/2
1
100
P812M912SM
9/16 – 3/4
1/2 – 3/4
100
P16M912
9/16 – 3/4
1
100
P16M24SM
1/8 – 1/4
1
100
P20M24
1/8 – 1/4
1 1/4
100
P16M58SM
5/16 – 1/2
1
100
100
P16M912SM
9/16 – 3/4
1
100
100
P20M24SM
1/8 – 1/4
1 1/4
100
5/16 – 1/2
1 1/4
100
P20M58
P20M912
H.3
• Suspend conduit from side of beam
• Will pivot 360°
• Hammer-on installation
• Static load capacity: 25 lbs. vertically
5/16 – 1/2
9/16 – 3/4
1 1/4
1 1/4
P24M24
1/8 – 1/4
1 1/2
100
P20M58SM
P24M58
5/16 – 1/2
1 1/2
100
P20M912SM
9/16 – 3/4
1 1/4
100
P24M912
9/16 – 3/4
1 1/2
100
P24M24SM
1/8 – 1/4
1 1/2
100
P32M24
1/8 – 1/4
2
100
P24M58SM
5/16 – 1/2
1 1/2
100
P32M58
5/16 – 1/2
2
100
P24M912SM
9/16 – 3/4
1 1/2
100
P32M912
9/16 – 3/4
2
100
P32M24SM
1/8 – 1/4
2
100
P32M58SM
5/16 – 1/2
2
100
P32M912SM
9/16 – 3/4
2
100
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.4
Supports & Fasteners
Stud Wall
Stud-Mounted Box
Support Brackets
Mount with
self-tapping screws
found on page H.49!
StrongHold ™ Stud Wall Part Numbers
Floor-Mounted Box Support Bracket –
Variable Height
• Bracket to support electrical boxes from
floor or channels
• Break-away feature allows product to be
used at three heights
• Manufactured from pre-galvanized steel
• User-supplied self-tapping screws attach
box to bracket
• Manufactured from pre-galvanized steel
PSGB16A
Std.
Pkg.
Qty.
Part Number
Description
PSGB16A
Mounts 2 1/2" deep electrical boxes to studs on 16"
centers.
50
PSGB24A
Mounts 2 1/2" deep electrical boxes to studs on 24"
centers.
50
H.5
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
PFBS18
Description
Std.
Pkg.
Qty.
Box support bracket to mount electrical boxes at
12", 16", or 18" heights.
Call 866-405-6654 or visit www.panduit.com/stronghold
50
H.6
Supports & Fasteners
Cable/Conduit
Push-Fit Conduit Clips with Beam Clamps
™
™
StrongHold
StrongHold
Cable/Conduit
Cable Tie Part
Part Numbers
Numbers
Cable Clips
• Available in bottom mount or side
mount options
• Will pivot 360°
• Hammer-on installation
• Static load capacity:
- 25 lbs. vertically for bottom mount (Image 1)
- 15 lbs. vertically for side mount (Image 2)
Image 1
• Support MC, AC, or BX cable from #12 – #8
wire in horizontal or vertical position
• No static load rating – for positioning only
• Can also be used for flexible metallic tubing,
armored cable, portable cables, and
control tubes
• See chart below for installation configurations
Part Number
PKX
Image 2
Part Number
H.7
Image
No.
Flange
Thickness
(In.)
Fits EMT
(In.)
Fits
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
Std.
Pkg.
Qty.
Description
Cable clip to support MC, AC, or BX cable
from drop wire.
Cable Size
(In.)
100
#12
Wire
#10
Wire
#8 – #9
Wire
P8P24
1
1/8 – 1/4
1/2
—
100
14-2 (0.43 – 0.48 O.D.)
PKX
PKX
PKX
P8P58
1
5/16 – 1/2
1/2
—
100
14-3 (0.45 – 0.50 O.D.)
PKX
PKX
PKX
P8P912
1
9/16 – 3/4
1/2
—
100
12-2 (0.47 – 0.51 O.D.)
PKX
PKX
PKX
P12P24
1
1/8 – 1/4
3/4
1/2
100
12-3 (0.49 – 0.54 O.D.)
PKX
PK8*
PK8*
P12P58
1
5/16 – 1/2
3/4
1/2
100
P12P912
1
9/16 – 3/4
3/4
1/2
100
P16P24
1
1/8 – 1/4
1
3/4
100
P16P58
1
5/16 – 1/2
1
3/4
100
P16P912
1
9/16 – 3/4
1
3/4
100
P8P24SM
2
1/8 – 1/4
1/2
—
100
P8P58SM
2
5/16 – 1/2
1/2
—
100
P8P912SM
2
9/16 – 3/4
1/2
—
100
P12P24SM
2
1/8 – 1/4
3/4
1/2
100
P12P58SM
2
5/16 – 1/2
3/4
1/2
100
P12P912SM
2
9/16 – 3/4
3/4
1/2
100
P16P24SM
2
1/8 – 1/4
1
3/4
100
P16P58SM
2
5/16 – 1/2
1
3/4
100
P16P912SM
2
9/16 – 3/4
1
3/4
100
Order number of pieces required, in multiples of Standard Package Quantity.
*See PK8 on Page A.7.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.8
Supports & Fasteners
Cable/Conduit
Conduit Clips
™
™
StrongHold
StrongHold
Cable/Conduit
Cable Tie Part
Part Numbers
Numbers
Multi-Function Clip Assemblies
• Support conduit from drop wire, rod, or flange
• No static load rating – for positioning only
• Can also be used for flexible metallic tubing,
armored cable, portable cables, and
control tubes
• See chart below for installation configurations
Part Number
Std.
Pkg.
Qty.
Description
PK8
Conduit clip to support 1/2" EMT from drop
wire, rod, or flange.
100
PK12
Conduit clip to support 3/4" EMT from drop
wire, rod, or flange.
100
PK16*
Conduit clip to support 1" EMT from drop
wire, rod, or flange.
100
PK20*
Conduit clip to support 1 1/4" EMT drop
wire, rod, or flange.
100
Image 1
• Components and assemblies used to secure
conduit and devices to drop wire, rod,
or flanges
• P4Z34 and assemblies fit 1/8" – 3/8" flanges
and attach to #12 wire through 3/8" rod
• P6Z34 fits 1/8" – 7/16" flanges and attaches
to #12 wire through 3/8" rod with
improved performance
• No static load rating – for positioning only
Image 2
Image 3
*Not UL or cUL listed.
#10 – #12
Wire
#8 –
#9
Wire
3/16" –
1/4"
Rod
1/8"–
1/4"
Flange
1/2 EMT
PK8
PK8
PK8
PK8
PK12
PK12
1/2 Rigid
PK8
PK12
PK12
PK12
PK12
PK16
3/4 EMT
PK12
PK12
PK12
PK12
PK16
PK16
3/4 Rigid
PK12
PK12
PK16
PK16
PK20*
PK20*
1 EMT
–
PK16
PK16
PK16
PK20*
PK20*
1 Rigid
–
–
–
PK20*
PK20*
PK20*
1 1/4 EMT
–
PK20
PK20
PK20
–
–
Conduit Size
(In.)
9/16"–
5/16"–
3/4"
1/2" Flange Flange
*For horizontal applications only.
Image
No.
Fits EMT
(In.)
Fits Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P4Z34*
1
—
—
100
P6Z34*
1
—
—
100
P4Z348P
2
1/2
—
100
P4Z3412P
2
3/4
1/2
100
P4Z3416P
2
1
3/4
100
P4Z34812M
3
1/2 – 3/4
1/2 – 3/4
100
P4Z3416M
3
1
1
100
Part Number
*UL and cUL listed.
Note: May require dedicated drop wire/rod and PEC311 – consult local authority.
H.9
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.10
Supports & Fasteners
Cable/Conduit
Conduit-To-Conduit Trapeze Assemblies with Snap-Close Clips
™
™
StrongHold
StrongHold
Cable/Conduit
Cable Tie Part
Part Numbers
Numbers
One-Piece Strut Clamps
• Designed to quickly secure one conduit run
to another
• No fasteners required
• Static load capacity: Total trapeze must
not exceed 100 lbs.
Part Number
Fits EMT/Rigid/IMC
(In.)
Std.
Pkg Qty.
3/8* to 1
100
P166M
P16812M
1/2 – 3/4 to 1
100
P1616M
1 to 1
100
P1620M
1 1/4 to 1
100
P1624M
1 1/2 to 1
100
*Or 14-2 through 12-3 MC/AC cable.
Conduit-To-Conduit Trapeze Assemblies with Push-Fit Clips
• Designed to quickly secure one conduit run
to another
• No fasteners required
• Static load capacity: 25 Ibs.
• Top conduit to be used for support only
Fits EMT
(In.)
Fits Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P8P8P
1/2 to 1/2
—
100
P8P12P
1/2 to 3/4
—
100
P8P16P
1/2 to 1
—
100
P12P12P
3/4 to 3/4
1/2 to 1/2
100
P12P16P
3/4 to 1
1/2 to 3/4
100
P16P16P
1 to 1
3/4 to 3/4
100
Part Number
H.11
Order number of pieces required, in multiples of Standard Package Quantity.
• Used to mount conduit to strut
• All sizes available with load distribution
saddle attached to screw to
distribute weight
• Suitable for use with standard 1 5/8" strut
• Install with screwdriver, nut driver, or
standard wrench
Static Load
Capacity
(Lbs.)
Std.
Pkg.
Qty.
—
—
100
—
50
100
3/4
1/2
50
50
PSCH16B
1
3/4
59
50
PSCH20B
1 1/4
1
75
50
PSCH24B
1 1/2
1 1/4
80
50
PSCH32B
2
1 1/2
100
25
PSCH40B
—
2
80
25
PSCH48B
2 1/2
2 1/2
125
25
PSCH56B
3
3
160
10
PSCH64B
3 1/2
3 1/2
200
10
PSCH72B
4
4
330
10
Fits EMT
(In.)
Fits Rigid/IMC
(In.)
PSCH6B
3/8
PSCH8B
1/2
PSCH12B
Part Number
Call 866-405-6654 or visit www.panduit.com/stronghold
H.12
Supports & Fasteners
Cable/Conduit
Universal Strut Clamps
• Break-apart strut clamp
• Install with screwdriver, nut driver, or
standard wrench
• Suitable for use with standard 1 5/8" strut
• Material: mild steel
™
™
StrongHold
StrongHold
Cable/Conduit
Cable Tie Part
Part Numbers
Numbers
Combination Box/Conduit Hangers from Drop Wire, Rod,
and Beams
• Secure 3/8" conduit (MC/AC cable) and 4"
square boxes to most structures
• Provide 3/8" conduit (MC/AC cable) support
on both sides of electrical box
• Available in a variety of mounting
configurations
Image 1
Fits EMT/Rigid/IMC
(In.)
Static
Load Rating
(Lbs.)
Std.
Pkg.
Qty.
PSK85I
1/2
200
100
PSK125I
3/4
200
100
PSK165I
1
200
100
PSK205I
1 1/4
200
100
PSK245I
1 1/2
200
50
PSK325I
2
200
50
PSK405I
2 1/2
350
50
PSK485I
3
350
50
PSK565I
3 1/2
350
25
PSK645I
4
350
25
Part Number
Image 2
Image 3
Image 4
Fits EMT/
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
#12 wire through 1/4"
flange
3/8*
25
2
Non-threaded center
hole for screw or
threaded rod mount
3/8*
25
P812MB18
1
#12 wire through 1/4"
rod
1/2 – 3/4
25
P812MB18A
2
Non-threaded
center hole for screw
or threaded rod mount
1/2 – 3/4
25
P812MB1824
3
1/8" through 1/4"
flange
1/2 – 3/4
25
Image
No.
Mounting
Method
P6MB18
1
P6MB18A
Part Number
*Or 14-2 through 12-3 MC/AC cable.
H.13
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.14
Supports & Fasteners
Cable/Conduit
Combination Box/Conduit Hangers from Drop Wire, Rod,
and Beams (continued)
H.15
Mounting
Method
Fits EMT/
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
1/2 – 3/4
25
Part Number
Image
No.
P812MB18S
4
1/4-20 x 9/16" stud
in center hole
P16MB18
1
#12 wire through
1/4" rod
1
25
P16MB18A
2
Non-threaded
center hole for
screw or threaded
rod mount
1
25
Order number of pieces required, in multiples of Standard Package Quantity.
™
™
StrongHold
StrongHold
Cable/Conduit
Cable Tie Part
Part Numbers
Numbers
Flexible Conduit/Cable Clips
• Suitable for flexible conduit and all types
of cable
• Support cable from 1/16" – 1/2" flange
• No static load rating – for positioning only
• Clip “snaps” on flange and cable “snaps”
into clip
Std.
Pkg.
Qty.
AC/MC Cable O.D. (In.)
Flange Size
(In.)
PSC2A
0.22 – 0.28
1/16 – 3/16
100
PSC2B
0.31 – 0.38
1/16 – 3/16
100
PSC2C
0.38 – 0.44
1/16 – 3/16
100
PSC2D
0.47 – 0.56
1/16 – 3/16
100
PSC2E
0.50 – 0.72
1/16 – 3/16
100
PSC2F
0.75 – 0.94
1/16 – 3/16
100
PSC2G
0.97 – 1.25
1/16 – 3/16
100
PSC4A
0.22 – 0.28
3/16 – 9/32
100
PSC4B
0.31 – 0.38
3/16 – 9/32
100
PSC4C
0.38 – 0.44
3/16 – 9/32
100
PSC4D
0.47 – 0.56
3/16 – 9/32
100
PSC4E
0.50 – 0.72
3/16 – 9/32
100
PSC4F
0.75 – 0.94
3/16 – 9/32
100
PSC4G
0.97 – 1.25
3/16 – 9/32
100
PSC8A
0.22 – 0.28
5/16 – 1/2
100
PSC8B
0.31 – 0.38
5/16 – 1/2
100
PSC8C
0.38 – 0.44
5/16 – 1/2
100
PSC8D
0.47 – 0.56
5/16 – 1/2
100
PSC8E
0.50 – 0.72
5/16 – 1/2
100
PSC8F
0.75 – 0.94
5/16 – 1/2
100
PSC8G
0.97 – 1.25
5/16 – 1/2
100
Part Number
Call 866-405-6654 or visit www.panduit.com/stronghold
H.16
Supports & Fasteners
Cable/Conduit
Flexible Cable Clip
Part Number
P449
• Properly space and support MC/AC cable
• Prevent derating of electrical cable
• Comply with NEC Article 310.15 (reference
pages O.4 – O.5 for details)
Std.
Pkg.
Qty.
12-2 (0.47 – 0.51 O.D.)
12-3 (0.49 – 0.54 O.D.)
14-2 (0.43 – 0.48 O.D.)
14-3 (0.46 – 0.50 O.D.)
Mount with
self-tapping screws
found on page H.49!
Support Brackets
for MC/AC Cable
• Push clip to attach MC or AC cable to
metal stud
• No tools required for installation
• Provides fast installation
Cable Size
(In.)
StrongHold ™ Cable/Conduit Part Numbers
Image 1
100
Image 2
Part Number
Flexible Conduit/Cable Hangers
• Bundle runs of MC and AC cable
• Can be used with variety of
mounting hardware
• Easy to close without the use of tools
Part Number
H.17
Description
Ultimate
Load
(Lbs.)
Std.
Pkg.
Qty.
PWMX3
Cable hanger for 1 1/8" diameter bundle – 3 runs of MC/AC.
50
100
PWMX6
Cable hanger for 1 3/4"
diameter bundle – 6 runs of
MC/AC.
75
100
Order number of pieces required, in multiples of Standard Package Quantity.
Image No.
Capacity
Std.
Pkg.
Qty.
PMCS50
1
Up to 4 runs of MC/AC cable
0.43" – 0.56" in diameter
100
PMCS100
2
Up to 8 runs of MC/AC cable
0.43" – 0.56" in diameter
50
PMCS101
2
Up to 7 runs of MC/AC cable
0.56" – 0.69" in diameter
50
Call 866-405-6654 or visit www.panduit.com/stronghold
H.18
Supports & Fasteners
Supports & Fasteners
Cable/Conduit
Nail/Conduit Brackets
Image 1
Beam/Purlin
Screw-On Beam Clamps
• Attach to beam with screw
• Install with screwdriver, nut driver, or
standard wrench
• Incorporate tapped holes to accommodate
threaded rod
• Attach conduit to wood, steel,
and concrete
• Eliminate offset bends on 1 1/2" box
• No static load rating – for positioning only
• May be attached after positioning conduit
PBC
PBC200
Image 2
Part Number
Image No.
PCNB812M
1
Fits EMT
(In.)
1/2 – 3/4
Fits Rigid/IMC
(In.)
Part
Number
Flange
Thickness
(In.)
1/2 – 3/4
100
PBC*
Up to 1/2
1/4-20 in
back and
bottom;
#10-24
in back
100
Spring
Steel
100
PBC200
Up to 1/2
1/4-20 in
back and
bottom
100
Zinc Plated Steel
50
Up to 15/16
3/8-16 in
back and
bottom
200
Zinc Plated Steel
25
PCNB8P
2
1/2
—
100
2
3/4
1/2
100
PBC400**
Metal Deck/Conduit Brackets
• Provide spacing between conduit and
deck surface
• Eliminate offset bends on 2 1/8" box
• No static load rating – for positioning only
• May be attached after positioning conduit
Part Number
H.19
Static
Load
Rating
(Lbs.)
Std.
Pkg.
Qty.
PCNB12P
Fits EMT
(In.)
PBC400
Fits Rigid/IMC
(In.)
Std.
Pkg.
Qty.
PAOL8P
1/2
—
100
PAOL12P
3/4
1/2
100
PAOL16P
1
3/4
100
Order number of pieces required, in multiples of Standard Package Quantity.
Tapped
Hole
Material
Std.
Pkg.
Qty.
*3/8" non-threaded clearance hole in top and bottom; 1/4" non-threaded
clearance hole in back.
**UL and cUL listed.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.20
Supports & Fasteners
Beam/Purlin
Hammer-On Beam Clamps
Hammer-On Beam Clamps with Attachment Tab
• Hammer-on installation
• Attachment tab provides 1/4" clearance hole
for wire, S-hooks, or chain assemblies
• Static load capacity: 200 lbs.
Image 1
Flange
Thickness
(In.)
Std.
Pkg.
Qty.
P4H24
1/8 – 1/4
100
P4H58
5/16 – 1/2
100
P4H912
9/16 – 3/4
100
Part
Number
H.21
StrongHold ™ Beam/Purlin Part Numbers
Order number of pieces required, in multiples of Standard Package Quantity.
• Hammer-on installation
• Provided with a 1/4-20 thread
so that boxes, fixtures, and bridle rings
may be quickly and securely attached to the
beam flanges (Image 1)
• Also available with 1/4-20 x 3/8" staked stud
for easier attachment of outlet boxes to
beams; eliminates need to use additional
screws (Image 2)
• Static load capacity: 75 lbs.
Image 2
Part
Number
Image
No.
Flange
Thickness
(In.)
Std.
Pkg.
Qty.
PM24
1
1/8 – 1/4
100
PM58
1
5/16 – 1/2
100
PM912
1
9/16 – 3/4
100
PM24S
2
1/8 – 1/4
100
PM58S
2
5/16 – 1/2
100
PM912S
2
9/16 – 3/4
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.22
Supports & Fasteners
Beam/Purlin
Reversible Beam Clamps
Image 1
Spring Steel Screw-On Beam Clamp Assemblies
• Easily attach conduit to beams
• Can be installed on flange up to 1/2" thick
• Include snap-close or push-fit
conduit fittings
• Used when drop-rod length must be
adjusted to accommodate a finished height
in the field
• Jam nut included to prevent
vibratory loosening
• Manufactured from malleable iron
Image 1
Image 2
Image 2
Image 3
Image
No.
Flange
Thickness
(In.)
Threaded Hole
Std.
Pkg.
Qty.
P3000037EG
1
3/4
3/8-16
25
P3000050EG
1
3/4
1/2-13
25
P3100037EG
2
1 1/4
3/8-16
25
PBC260025EG
3
1 1/4
1/4-20
50
Part
Number
H.23
StrongHold ™ Beam/Purlin Part Numbers
Order number of pieces required, in multiples of Standard Package Quantity.
Image 3
Image 4
Fits
Rigid/IMC
(In.)
Static
Load
Rating
(Lbs.)
Std.
Pkg.
Qty.
Part
Number
Image
No.
Fits
EMT
(In.)
PBC8P
1
1/2
—
25
100
PBC12P
1
3/4
1/2
25
100
PBC16P
1
1
3/4
25
100
PBC8PSM
2
1/2
—
15
100
PBC12PSM
2
3/4
1/2
15
100
PBC16PSM
2
1
3/4
15
100
PBC812M
3
1/2 – 3/4
1/2 – 3/4
100
100
PBC16M
3
1
1
100
100
PBC20M
3
1 1/4
1 1/4
100
100
PBC24M
3
1 1/2
1 1/2
100
100
PBC32M
3
2
2
100
100
PBC812MSM
4
1/2 – 3/4
1/2 – 3/4
25
100
PBC16MSM
4
1
1
25
100
PBC20MSM
4
1 1/4
1 1/4
25
100
PBC24MSM
4
1 1/2
1 1/2
25
100
PBC32MSM
4
2
2
25
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.24
Supports & Fasteners
Beam/Purlin
Screw-On Beam Clamp Assemblies with
Conduit Clamps
StrongHold ™ Beam/Purlin Part Numbers
Hammer-On Beam Clamps with Rod Hanger
• Easily attach conduit to beams up to 1/2" thick
• Conduit clamps provide positive
securing feature
• Suitable for EMT or Rigid/IMC conduit
Image 1
Part
Number
Fits
EMT
(In.)
Fits
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
PBC200CD1B
3/4
3/4
100
PBC200CD2B
1
1
100
PBC200CD2.5B
1 1/4
—
100
PBC200CD3B
1 1/2
1 1/4
100
PBC200CD4B
—
1 1/2
50
PBC200CD5B
2
2
50
• Hammer-on beam clamps allow for
easy installation
• Options available for threaded or
non-threaded rod
• Options available for flanges 1/8" – 3/4" thick
• Static load capacity: 160 lbs.
Image 2
Image 3
Image 4
Flange
Thickness
(In.)
Rod
Size
Std.
Pkg.
Qty.
1
1/8 – 1/4
1/4-20 threaded
100
1
5/16 – 1/2
1/4-20 threaded
100
P4TI912
1
9/16 – 3/4
1/4-20 threaded
100
P6TI24
1
1/8 – 1/4
3/8-16 threaded
100
P6TI58
1
5/16 – 1/2
3/8-16 threaded
100
P6TI912
1
9/16 – 3/4
3/8-16 threaded
100
P6TA24*
2
1/8 – 1/4
1/4" – 3/8";
requires nuts
100
P6TA58*
2
5/16 – 1/2
1/4" – 3/8";
requires nuts
100
P6A24
3
1/8 – 1/4
3/8" non-threaded
100
P6A58
3
5/16 – 1/2
3/8" non-threaded
100
P6A912
3
9/16 – 3/4
3/8" non-threaded
100
P70824
4
1/8 – 1/4
8 wire or 1/4" plain rod
100
P70858
4
5/16 – 1/2
8 wire or 1/4" plain rod
100
P708912
4
9/16 – 3/4
8 wire or 1/4" plain rod
100
Part
Number
Image
No.
P4TI24
P4TI58
*UL and cUL listed.
H.25
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.26
Supports & Fasteners
Beam/Purlin
Purlin Clips – Spring Steel
PVF14
StrongHold ™ Beam/Purlin Part Numbers
Z-Purlin Clips
• Fasteners fit flanges 1/16" – 1/4" thick
• Support wire and assemblies from vertical
or angled flanges
• Hammer-on installation
• Material: spring steel
• Static load capacity: 100 lbs.
• Provide a method for attaching conduit and
boxes to angled flanges
• Installed by hand without the use of
power tools
• Static load capacity: 100 lbs.
P122
PAF14
P123
Part
Number
Flange
Orientation
Std.
Pkg.
Qty.
Part
Number
PVF14
Vertical
100
P122
100
PAF14
Angled
100
1/4" hole for wire, S-hooks, and
jack chain.
P123
1/4" hole in bottom for assemblies.
100
H.27
Order number of pieces required, in multiples of Standard Package Quantity.
Description
Call 866-405-6654 or visit www.panduit.com/stronghold
Std.
Pkg.
Qty.
H.28
Supports & Fasteners
Beam/Purlin
Purlin Clip Assemblies for Threaded Rod
and Drop Wire Applications
Image 1
Z-Purlin Clip Assemblies for Conduit Applications
• Provide a method for attaching conduit
to angled flanges
• Installed by hand without the use of
power tools
• Suspend threaded rod and drop wire from
vertical flange
• Hammer-on installation
• Material: spring steel
• Static load capacity: 160 lbs.
• Flange thickness: 1/16" – 5/32"
Image 1
Image 2
Image 2
Image
No.
Rod
Size
Std.
Pkg.
Qty.
PVF144TI
1
1/4-20 threaded
PVF146TI
1
3/8-16 threaded
Part
Number
PVF146T
PVF14708
StrongHold ™ Beam/Purlin Part Numbers
1
2
1/4" – 3/8" requires nuts
#8 wire or 1/4" plain rod
Fits
Rigid/IMC
(In.)
Static
Load
Rating
(Lbs.)
Std.
Pkg.
Qty.
100
Part
Number
Image
No.
Fits
EMT
(In.)
100
P1238P
1
1/2
—
25
100
100
P12312P
1
3/4
1/2
25
100
100
P12316P
1
1
3/4
25
100
P1236M
2
3/8
3/8
100
100
P123812M
2
1/2 – 3/4
1/2 – 3/4
100
100
P12316M*
2
1
1
100
100
P12320M
2
1 1/4
1 1/4
100
100
*UL and cUL listed.
H.29
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.30
Supports & Fasteners
Supports & Fasteners
Beam/Purlin
Hangers/Hanging Systems
Rod and Wire Hangers with Bracket Supports
Z-Purlin Clip Assemblies for Threaded Rod
and Drop Wire Applications
• Provide a method for attaching conduit
and boxes to angled flanges
• Installed by hand without the use of
power tools
• Static load capacity: 100 lbs.
Image 1
• Suspend #8 wire, 1/4", and 3/8"
non-threaded or threaded rod from
overhead mountings
• 1/4" clearance hole in right angle and
offset brackets
• Static load capacity: 160 lbs.
Image 1
Image 3
Image 4
Image 5
Image 6
Image 7
Image 3
Image 2
Part
Number
Image
No.
Rod Size
Std.
Pkg.
Qty.
P1224TI
1
1/4-20 threaded
100
P1226TI
1
3/8-16 threaded
100
P1226T
2
1/4" – 3/8" threaded; requires nuts
100
P122708
3
#8 wire or 1/4" plain rod
100
H.31
Image 2
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
P4TIB
Image
No.
1
Rod Size
1/4-20
threaded rod
Bracket Orientation
Std.
Pkg.
Qty.
Right Angle
100
P6TIB
1
3/8-16 threaded rod
Right Angle
100
P6TB
2
1/4" – 3/8" threaded
rod; requires nut
Right Angle
100
P6AO
3
3/8 non-threaded rod
Offset
100
P4TIO
4
1/4-20
threaded rod
Offset
100
P6TIO
4
3/8-16
threaded rod
Offset
100
P6TO
5
1/4" – 3/8" threaded
rod; requires nut
Offset
100
P708AB
6
#8 wire or
1/4" plain rod
Right Angle
100
P708AO
7
#8 wire or
1/4" plain rod
Offset
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.32
Supports & Fasteners
Supports & Fasteners
Hangers/Hanging Systems
Strap Hangers
Stud Wall
Electrical Box
Mounting Support Brackets
• Support pipe or duct from flange with
banding or strapping up to 1" wide
• Options available for beams 1/8" – 3/4" thick
• Hammer-on installation
• Static load capacity: 200 lbs.
Image 1
Image 1
Mount with
self-tapping screws
found on page H.49!
• Attach 4" or 4 11/16" electrical outlet
boxes to studs
• Support feature reduces box movement
in wall
• Manufactured from pre-galvanized steel
• Comply with NEC Article 300.4 (D)
(reference pages O.1 for details)
Image 2
Part Number
Image
No.
Flange
Thickness
(In.)
Std.
Pkg.
Qty.
PMSS24
1
1/8 – 1/4
100
PMSS58
1
5/16 – 1/2
100
PMSS912
1
9/16 – 3/4
100
PMSR24
2
1/8 – 1/4
100
PMSR58
2
5/16 – 1/2
100
PMSR912
2
9/16 – 3/4
100
H.33
Order number of pieces required, in multiples of Standard Package Quantity.
Image 2
Part Number
Image No.
Stud Depth
(In.)
Std.
Pkg.
Qty.
PH23
1
2 1/2 and 3 1/2
100
PH4
1
2 1/2, 3 1/2, and 4
100
PH6
1
6
100
PMEB1
2
2 1/2, 3 1/2, and 4
25
Call 866-405-6654 or visit www.panduit.com/stronghold
H.34
Supports & Fasteners
Stud Wall
Mount with
self-tapping screws
found on page H.49!
Screw-On
Conduit Supports
StrongHold ™ Stud Wall Part Numbers
• Comply with NEC Article 358.30 to support
conduit close to electrical box
• Accommodate EMT and MC/AC cable
• Allow conduit to align with box knockouts
when used with PH series brackets
(see page H.1)
• Secure electrical boxes to most metal studs
• Include 1/4" hole to secure to stud with
user-supplied screw
• Hammer-on installation
PMSF
Fits EMT
(In.)
Electrical
Box Depth
Color
Std.
Pkg.
Qty.
PCS16*
1
2 1/8
Black
100
PCS812
1/2 – 3/4
1 1/2
Black
100
PCS812D
1/2 – 3/4
2 1/8
Silver
100
Part Number
Mount with
self-tapping screws
found on page H.49!
Hammer-On Box
to Stud Supports
*Not UL or cUL listed.
PMFS
Part Number
PMFO
Description
Std.
Pkg.
Qty.
PMSF
Box to stud support – non-adjustable.
100
PMFS
Box to stud support with screw,
adjustable for 1/4" – 3/4" dry wall.
100
PMFO
Box to stud support flush to stud face –
preset.
100
Press-On Nail Plate
• Fast installation; no tools required
• Protects electrical, datacom, and
plumbing infrastructure
• Meets NEC Article 300.4 requirements
(reference pages O.1 for details)
Part Number
P304B2
H.35
Description
Press-on nail plate for wood or metal studs.
Std.
Pkg.
Qty.
100
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.36
Supports & Fasteners
Stud Wall
Switch Box to Metal
Stud Brackets
Mount with
self-tapping screws
found on page H.49!
StrongHold ™ Stud Wall Part Numbers
• Designed to quickly install conduit to
metal studs
• Available in push-fit (Image 1) or snap-close
(Image 2) fittings
• Suitable for both EMT and Rigid/IMC conduit
• Secure electrical boxes to most metal studs
• Preset versions offset for specific
dry wall thickness
• Include 1/4" hole to secure to stud with
user-supplied screw
• Hammer-on installation
Part Number
Dry Wall Thickness
(In.)
Image 1
Std.
Pkg.
Qty.
PMF250
1/4
100
PMF375
3/8
100
PMF500
1/2
100
PMF625
5/8
100
PMF750
3/4
100
Image 2
Image No.
Fits EMT (In.)
Fits Rigid/IMC (In.)
Std.
Pkg.
Qty.
P8PF
1
1/2
—
100
P12PF
1
3/4
1/2
100
P16PF
1
1
3/4
100
P6MF
2
3/8
3/8
100
P812MF
2
1/2 – 3/4
1/2 – 3/4
100
P16MF
2
1
1
100
Part Number
H.37
Mount with
self-tapping screws
found on page H.49!
Hammer-On Conduit
to Metal Stud Brackets
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.38
Supports & Fasteners
Cable Ties
Stud Wall
Mount with
self-tapping screws
found on page H.49!
Screw-On Box to
Stud Support
StrongHold ™ Stud Wall Part Numbers
Far-Side Box Supports
• Installs to stud with user-supplied screws
• For use with metal or wood studs
• Used independently or with assemblies
for electrical box or conduit support
Part Number
Std.
Pkg.
Qty.
Description
P350
Image 1
• Clip to electrical box to utilize dry wall on
far side of box for support
• Used with 1 1/2" or 2 1/8" deep
electrical box
• Prevent electrical box from recessing into
wall cavity
• No static load rating – for positioning only
Screw-mounted box to stud support.
100
Image 2
Image 3
Screw-On Conduit
to Stud Supports
Mount with
self-tapping screws
found on page H.49!
Image
No.
Figure
No.
Stud Depth
(In.)
Std.
Pkg.
Qty.
PJ1A25
1
1
2 1/2
100
PJ1A35
1
1
3 1/2
100
PJ1A4
1
1
4
100
PJ1A6
1
1
6
100
P766
2
1
2 1/2 – 4
100
P766PMD
3
2
3 5/8
100
Part Number
• Designed to install runs of conduit to
metal studs
• Suitable for EMT and Rigid/IMC conduit
• Available in push-fit (Image 1) or snap-close
(Image 2) fittings
Image 1
Image 2
Image No.
Fits EMT
(In.)
Fits Rigid/IMC (In.)
Std.
Pkg.
Qty.
P3508P
1
1/2
—
100
P35012P
1
3/4
1/2
100
P35016P
1
1
3/4
100
P350812M
2
1/2 – 3/4
1/2 – 3/4
100
P35016M
2
1
1
100
Part Number
Mud ring
Cut off here for
deep box applications
H.39
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.40
Supports & Fasteners
Stud Wall
Adjustable Screw Gun
Box Mounting Brackets
Mount with
self-tapping screws
found on page H.49!
Rigid Box
Mounting Brackets
Description
Mount with
self-tapping screws
found on page H.49!
• Used to secure multiple electrical boxes in
stud walls
• Mount 1 1/2" or 2 1/8" deep electrical boxes
• Suitable for 4" or 4 11/16" wide
electrical boxes
• Adjustable to allow variability between
stud spacing
• Utilized to mount electrical box
between studs
• Suitable for 1 1/2" or 2 1/8" deep
electrical boxes
Part Number
StrongHold ™ Stud Wall Part Numbers
PRBS16
Std.
Pkg.
Qty.
PTSGB16
Mount box between studs spaced
11" – 18".
50
PTSGB24
Mount box between studs spaced
17" – 26".
50
PRBS24
Part Number
Description
Std.
Pkg.
Qty.
PRBS16
Rigid box mounting bracket for 16" stud spacing;
capacity of three electrical boxes.
50
PRBS24*
Rigid box mounting bracket for 24" stud spacing;
capacity of four electrical boxes.
25
*Not UL or cUL listed.
H.41
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.42
Supports & Fasteners
Stud Wall
Floor-Mounted Box Bracket
Mount with
self-tapping screws
found on page H.49!
StrongHold ™ Stud Wall Part Numbers
• Supports electrical box at consistent
spacing from floor level
• Features can be used to prevent electrical
box from being pushed into wall cavity
• Mounts 4" or 4 11/16" wide electrical
boxes; 1 1/2" or 2 1/8" deep
• Meets ADA (Americans with Disabilities Act)
accessibility guidelines/standards
Part Number
PFMBS18
Description
Floor-mounted box bracket to mount
center of electrical box 18" off floor.
Std.
Pkg.
Qty.
• Used to maintain appropriate cable
spacing behind dry wall to comply with
NEC Article 300.4 (D) (reference pages
O.1 – O.2 for details)
• Attaches to wood or metal stud with
user-supplied screws
• Accommodates a variety of cable types
Part Number
PCJ6
25
Cable Type
H.43
Mount with
self-tapping screws
found on page H.49!
Cable
Support Clip
Order number of pieces required, in multiples of Standard Package Quantity.
Std.
Pkg.
Qty.
Description
Cable support clip to provide 1 1/2" spacing for
cables behind dry wall.
Cables
Per
Clip
100
Cable Size
Non-metallic
6
14-2, 12-2, 10-2, 14-3, 12-3, 10-3 with
ground
Non-metallic
4
8-2, 6-2 with ground
MC/AC
4
14-2, 12-2, 10-2, 14-3, 12-3, 10-3,
14-4, 12-4, 10-4 with ground
Call 866-405-6654 or visit www.panduit.com/stronghold
H.44
Supports & Fasteners
Stud Wall
Anti-Rattle Bracket
Mount with
self-tapping screws
found on page H.49!
StrongHold ™ Stud Wall Part Numbers
Cable Support Clip
for Single Cable
• Used as noise reduction and to stop rattling
from Conduit, BX Cable, Armored Cable
(EMT, MC/AC), or Rigid Conduit, when pulled
through metal studs
• Attaches to metal stud with user supplied
self-tapping screws
• Accommodates a variety of cable types up
to 1" in diameter
• Meets ADA (Americans with Disabilities Act)
accessibility guidelines/standards
Part Number
SH781
H.45
Description
Anti-rattle bracket for support of armored cable and
conduit up to 1" in diameter, through metal stud
wall.
Std.
Pkg.
Qty.
Mount with
self-tapping screws
found on page H.49!
• Used to maintain appropriate cable
spacing behind dry wall to comply with
NEC Article 300.4 (D) (reference pages
O.1 – O.2 for details)
• Provides 1 1/2" spacing for cables
behind dry wall
• Attaches to wood or metal studs
with hammer
Part Number
PFXC20
Description
Std.
Pkg.
Qty.
Accommodates MC/AC cable (12-2 through 10-3).
100
100
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.46
Supports & Fasteners
Stud Wall
Mount with
self-tapping screws
found on page H.49!
Through-Stud
Conduit Supports
StrongHold ™ Stud Wall Part Numbers
Metal Stud Grommets
• Install in pre-punched hole in metal studs
• Protect cable within the building structure
• Utilize metal stud punch tool (see page H.18)
to create suitable holes in specific locations
• Designed to secure horizontal runs of
conduit through metal studs
• Eliminate rattling conduit
• Available with push-fit (Image 1) or
snap-close (Image 2) conduit fittings
MSG-1.3-C
Image 1
MSGV-1.3-C
Image 2
Image
No.
Fits EMT (In.)
Fits Rigid/IMC (In.)
Std.
Pkg.
Qty.
PFB8P
1
1/2
—
100
PFB12P
1
3/4
1/2
100
PFB6M
2
3/8
3/8
100
PFB812M
2
1/2 – 3/4
1/2 – 3/4
100
Part Number
H.47
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
Description
Std.
Pkg.
Qty.
MSG-1.3-C
Metal stud grommet.
100
MSGV-1.3-C
Metal stud grommet, anti-vibration tabs for
1/2" – 1" pipe.
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.48
Supports & Fasteners
Stud Wall
Cable Manager
StrongHold ™ Stud Wall Part Numbers
Metal Stud Punch Tool
• Installs in pre-punched hole in metal studs
• Protects cable within the building structure
• Utilizes metal stud punch tool (see page
H.18) to create suitable holes in
specific locations
Part Number
CSM-1.25-C
Description
Cable stud manager for 1 1/4"
cable spacing.
• Punches 1 11/32" round hole in 25 gauge
minimum to 20 gauge maximum mild
steel studs
• Contoured handle allows for
increased leverage
• Automatic hole centering on standard width
(3 5/8") studs
• Replaceable punch and dies
• Self-stripping design that eliminates
punch malfunctions
Std.
Pkg.
Qty.
100
Part Number
MSPT-1.3
Std.
Pkg.
Qty.
Description
Metal stud punch tool.
1
Self-Tapping Screw
• Used to secure StrongHold™ components to
metal studs
• Low profile head utilizes #2 phillips head
• Packaging: plastic job jar
Part Number
PSMS8
H.49
Order number of pieces required, in multiples of Standard Package Quantity.
Description
8 x 1/2" low profile self-tapping screw.
Std.
Pkg.
Qty.
1000
Call 866-405-6654 or visit www.panduit.com/stronghold
H.50
Supports & Fasteners
Communications/
Low Voltage
StrongHold™ Communications/Low Voltage Part Numbers
J-Pro™ Series Referenced Images
J-Pro™ JP75 Series
• UL listed for use in plenum or air handling spaces (such as ceiling
voids and underfloor areas) per NEC Article 300.22 (C) and (D)
(reference pages O.2 – O.4 for details)
• Complete horizontal and vertical 1" bend radius control
• Bundle capacity: 3/4"
• Cable capacity: Category 6A (5), Category 6A (SD) (8),
Category 6 (8), Category 5e (10)
Image 1
Image 4
Image 7
Image 10
Image 2
Image 5
Image 8
Image 11
Image 3
Image 6
Image 9
Std.
Pkg.
Qty.
Part Number
Image
No.
JP75W-L20
1
Wall mount – one 1/4" mounting
hole.
50
JP75WP2B-L20
2
Wall mount for powder actuated
fasteners – one 5/32" and one 1/4"
mounting hole.
50
JP75CMB-L20
3
Ceiling mount – 3/16", 1/4", and 3/8"
mounting holes.
50
JP75DW-L20
4
Drop wire and threaded rod clip
mount.
50
JP75SBC50-L20
5
Screw-on beam clamp mount – up
to 1/2" flange.
50
JP75SBC50RB-L20
6
Screw-on beam clamp mount – up
to 1/2" flange. Rotates 360°.
50
JP75SBC87-L20
7
Screw-on beam clamp mount – up
to 3/4" flange.
50
JP75SBC87RB-L20
8
Screw-on beam clamp mount – up
to 3/4" flange. Rotates 360°.
50
JP75HBC25RB-L20
9
Hammer-on beam clamp mount –
1/8" - 1/4" flange. Rotates 360°.
50
JP75HBC50RB-L20
9
Hammer-on beam clamp mount –
5/16" – 1/2" flange. Rotates 360°.
50
JP75HBC75RB-L20
9
Hammer-on beam clamp mount –
9/16" – 3/4" flange. Rotates 360°.
50
JP75CP-L20
10
C-purlin clips for straight flanges
up to 1/4" thick.
50
JP75ZP-L20
11
Z-purlin clips for angled flanges up
to 1/4" thick.
50
JP75UF100-L20
12
Underfloor pedestal support clip
for pedestal 7/8" square or 1 1/8" –
1 3/8" in diameter.
50
Description
Image 12
Available colors can be
found on page H.57
H.51
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.52
Supports & Fasteners
Communications/
Low Voltage
StrongHold™ Communications/Low Voltage Part Numbers
J-Pro™ JP131 Series
J-Pro™ JP2 Series
• Bundle capacity: 1 5/6"
• Cable capacity: Category 6A (15), Category 6A (SD) (25),
Category 6 (25), Category 5e (29)
• Bundle capacity: 2"
• Cable capacity: Category 6A (30), Category 6A (SD) (46),
Category 6 (46), Category 5e (55)
Part Number
JP131W-L20
Image
No.
1
Std.
Pkg.
Qty.
Wall mount – one 1/4" mounting
hole.
50
Description
JP131WP2B-L20
2
Wall mount for powder actuated
fasteners – one 5/32" and one 1/4"
mounting hole.
50
JP131CMB-L20
3
Ceiling mount – 3/16", 1/4", and
3/8" mounting holes.
50
JP131DW-L20
4
Drop wire and threaded rod clip
mount.
50
JP131SBC50-L20
5
Screw-on beam clamp mount – up
to 1/2" flange.
50
JP131SBC50RBL20
6
Screw-on beam clamp mount – up
to 1/2" flange. Rotates 360°.
50
JP131SBC87-L20
7
Screw-on beam clamp mount – up
to 3/4" flange.
50
JP131SBC87RBL20
8
Screw-on beam clamp mount – up
to 3/4" flange. Rotates 360°.
50
JP131HBC25RBL20
9
Hammer-on beam clamp mount –
1/8" – 1/4" flange. Rotates 360°.
50
JP131HBC50RBL20
9
Hammer-on beam clamp mount –
5/16" – 1/2" flange. Rotates 360°.
50
JP131HBC75RBL20
9
Hammer-on beam clamp mount –
9/16" – 3/4" flange. Rotates 360°.
50
JP131CP-L20
10
C-purlin clips for straight flanges up
to 1/4" thick.
50
JP131ZP-L20
11
Z-purlin clips for angled flanges up
to 1/4" thick.
50
JP131UF100-L20
12
Underfloor pedestal support clip for
pedestal 7/8" square or 1 1/8" –
1 3/8" in diameter.
50
H.53
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
Image
No.
Description
Std.
Pkg.
Qty.
JP2W-L20
1
Wall mount – one 1/4" mounting hole.
50
JP2WP2B-L20
2
Wall mount for powder actuated
fasteners – one 5/32" and one 1/4"
mounting hole.
50
JP2CMB-L20
3
Ceiling mount – 3/16", 1/4", and 3/8"
mounting holes.
50
JP2DW-L20
4
Drop wire and threaded rod clip
mount.
50
JP2SBC50-L20
5
Screw-on beam clamp mount – up to
1/2" flange.
50
JP2SBC50RB-L20
6
Screw-on beam clamp mount – up to
1/2" flange. Rotates 360°.
50
JP2SBC87-L20
7
Screw-on beam clamp mount – up to
3/4" flange.
50
JP2SBC87RB-L20
8
Screw-on beam clamp mount – up to
3/4" flange. Rotates 360°.
50
JP2HBC25RB-L20
9
Hammer-on beam clamp mount –
1/8" – 1/4" flange. Rotates 360°.
50
JP2HBC50RB-L20
9
Hammer-on beam clamp mount –
5/16" – 1/2" flange. Rotates 360°.
50
JP2HBC75RB-L20
9
Hammer-on beam clamp mount –
9/16" – 3/4" flange. Rotates 360°.
50
JP2CP-L20
10
C-purlin clips for straight flanges up
to 1/4" thick.
50
JP2ZP-L20
11
Z-purlin clips for angled flanges up to
1/4" thick.
50
JP2UF100-L20
12
Underfloor pedestal
support clip for pedestal 7/8" square
or 1 1/8" –1 3/8" in diameter.
50
Call 866-405-6654 or visit www.panduit.com/stronghold
H.54
Supports & Fasteners
Communications/
Low Voltage
J-Pro™ JP4 Series
StrongHold™ Communications/Low Voltage Part Numbers
J-Pro™ Extension Bracket
• Bundle capacity: 4"
• Cable capacity: Category 6A (115), Category 6A (SD) (180),
Category 6 (180), Category 5e (200)
Part Number
Image
No.
Description
Std.
Pkg.
Qty.
JP4W-X20
1
Wall mount – one 1/4" mounting hole.
10
JP4WP2B-X20
2
Wall mount for powder actuated
fasteners – one 5/32" and one 1/4"
mounting hole.
10
• Compatible with 3/4", 1 5/16", and 2"
J-Pro™ products
• Allows multiple hooks to be installed
utilizing one attachment point
• Includes 1/8", 1/4", and 3/8" mounting holes
for various user-supplied hardware
Part Number
PCATHBA
JP4CMB-X20
3
Ceiling mount – 3/16", 1/4", and 3/8"
mounting holes.
10
JP4SBC50-X20
5
Screw-on beam clamp mount – up to
1/2" flange.
10
JP4SBC50RB-X20
6
Screw-on beam clamp mount – up to
1/2" flange. Rotates 360°.
10
JP4SBC87-X20
7
Screw-on beam clamp mount – up to
3/4" flange.
10
JP4SBC87RB-X20
8
Screw-on beam clamp mount – up to
3/4" flange. Rotates 360°.
10
JP4HBC25RB-X20
9
Hammer-on beam clamp mount –
1/8" – 1/4" flange. Rotates 360°.
10
JP4HBC50RB-X20
9
Hammer-on beam clamp mount –
5/16" – 1/2" flange. Rotates 360°.
10
JP4HBC75RB-X20
9
Hammer-on beam clamp mount –
9/16" – 3/4" flange. Rotates 360°.
10
JP4CP-X20
10
C-purlin clips for straight flanges up
to 1/4" thick.
10
JP4ZP-X20
11
Z-purlin clips for angled flanges up to
1/4" thick.
10
JP4UF100-X20
12
Underfloor pedestal support clip for
pedestal 7/8" square or 1 1/8" – 1
3/8" in diameter.
10
Description
Multi-tier bracket for J-Pro™ product line.
Bend appropriate tabs with
flathead screwdriver to prevent
intended hook from rotating
once installed.
Order number of pieces required, in multiples of Standard Package Quantity.
10
Install appropriate J-Pro™
wall-mounted hook with
user-supplied hardware.
To mount additional hooks to
the same bracket, bend the
appropriate tabs with flathead
screwdriver to prevent hook
from rotating once installed.
H.55
Std.
Pkg.
Qty.
Install additional J-Pro™
wall-mounted hook with
user-supplied hardware.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.56
Supports & Fasteners
Communications/
Low Voltage
J-Pro™ Color Selection Guide
StrongHold™ Communications/Low Voltage Part Numbers
J-Pro™ Color Selection Guide (continued)
Base
Part Number
Black
Red
JP75W
-L20
-L2
JP75WP2B
-L20
JP75CMB
-L20
-L2
JP75DW
-L20
-L2
JP75ZP
JP75CP
Blue
White
Green
Orange
-L5
-L3
Base
Part Number
Black
JP2HBC75RB
-L20
JP2UF100
-L20
JP4W
-X20
JP4WP2B
-X20
-L20
JP4CMB
-X20
-L20
JP4ZP
-X20
JP75SBC50
-L20
JP4CP
-X20
JP75SBC87
-L20
JP4SBC50
-X20
JP75SBC50RB
-L20
JP4SBC87
-X20
JP75SBC87RB
-L20
JP4SBC50RB
-X20
JP75HBC25RB
-L20
JP75HBC50RB
-L20
JP4SBC87RB
-X20
JP75HBC75RB
-L20
JP4HBC25RB
-X20
JP75UF100
-L20
JP4HBC50RB
-X20
JP131W
-L20
JP4HBC75RB
-X20
JP131WP2B
-L20
JP4UF100
-X20
JP131CMB
-L20
JP131DW
-L20
JP131ZP
-L20
JP131CP
-L20
JP131SBC50
-L20
JP131SBC87
-L20
JP131SBC50RB
-L20
JP131SBC87RB
-L20
JP131HBC25RB
-L20
JP131HBC50RB
-L20
JP131HBC75RB
-L20
JP131UF100
-L20
JP2W
-L20
JP2WP2B
-L20
-L2
-L
-L6
-L5
-L3
-L5
-L3
Blue
White
-X2
-X6
-X
Green
Orange
-X
-X2
-X
-X2
-X
-L6
-L2
-L
-L2
-L
-L2
JP2CMB
-L20
-L2
-L20
-L2
JP2ZP
-L20
JP2CP
-L20
JP2SBC50
-L20
JP2SBC87
-L20
JP2SBC50RB
-L20
-L2
JP2SBC87RB
-L20
-L2
JP2HBC25RB
-L20
H.57
-L
-L2
JP2DW
JP2HBC50RB
-L20
Table continues on page H.57
-L6
Red
-L6
-L
-L6
-L
-L
-L2
-L
-L
Order number of pieces required, in multiples of Standard Package Quantity.
Additional colors available, contact your local sales representative
or go to www.panduit.com for availability.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.58
Supports & Fasteners
Communications/
Low Voltage
StrongHold™ Communications/Low Voltage Part Numbers
J-Mod® Series Installation Instructions
J-Mod® Series Referenced Images
• UL listed for use in plenum or air handling spaces (such as
ceiling voids and underfloor areas) per NEC Article 300.22
(C) and (D) (reference pages O.2 – O.4 for details)
• Complete horizontal and vertical 1" bend radius control
Image 1
H.59
Image 2
Image 3
Image 4
Image 5
Image 6
Image 7
Image 8
Image 9
Image 10
Image 11
Order number of pieces required, in multiples of Standard Package Quantity.
Align snap lock
Align chaining bracket
attachment of J-hook under the assembly.
with holes in chosen
bracket and snap
J-hook into place.
Pull down to
fully engage.
Slide chaining bracket
between J-hook and
the metal bracket until
it snaps.
Attach J-hooks as
Final assembly
explained in first-level is a second-level
installation above.
installation consisting
of one threaded rod
bracket, one chaining
bracket, and two
J-hooks for clarity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.60
Supports & Fasteners
Communications/
Low Voltage
J-Mod® Series
StrongHold™ Communications/Low Voltage Part Numbers
Hook and Loop Cable Ties
• Bundle capacity: 2"
• Cable capacity: Category 6A (30), Category 6A (SD) (46),
Category 6 (46), Category 5e (55)
Part Number
JMJH2W-X20
Image
No.
1
Description
Std.
Pkg.
Qty.
J-hook for wall mount applications only;
two 1/4" mounting holes for user
supplied screws.
10
JMJH2-X20
2
J-hook for use with J-Mod® brackets.
10
JMCB-X
3
Chaining bracket to extend existing
J-Mod® capacity; for use with
single-level mounting brackets; three
levels maximum.
10
JMCMB25-1-X
4
Single-level ceiling mount bracket with
one 1/4" mounting hole.
10
JMCMB25-3-X
5
Three-level ceiling mount bracket with
one 1/4" mounting hole.
10
JMDWB-1-X
6
Single-level drop wire bracket that
attaches to #12 wire or 1/4"
threaded rod.
10
Image 1
• Soft, premium material is safe for use on
high-performance communication cable
• UL listed for use in plenum or air handling
spaces (such as ceiling voids and
underfloor areas) per NEC Article 300.22
(C) and (D) (reference pages O.2 – O.4
for details)
• Material flammability rating: UL 94V-2
• Adjustable, releasable, and re-useable
multiple times; ideal for moves, adds,
and changes
Image 2
Part Number
Image
No.
Length
(In.)
Width
(In.)
Max.
Bundle
Dia.
(In.)
HLTP2I-X12
1
8.00
0.50
1.91
Maroon
10
HLTP3I-X12
1
12.00
0.50
3.18
Maroon
10
Color
Std.
Pkg.
Qty.
HLTP2I-X0
1
8.00
0.50
1.91
Black
10
HLTP3I-X0
1
12.00
0.50
3.18
Black
10
JMDWB-3-X
7
Three-level drop wire bracket that
attaches to #12 wire or 1/4"
threaded rod.
10
HLSP1.5S-X12
2
6.00
0.75
1.50
Maroon
10
JMTRB38-1-X
8
Single-level threaded rod bracket;
accepts 1/4" – 3/8" threaded rod.
10
HLSP3S-X12
2
12.00
0.75
3.20
Maroon
10
HLSP5S-X12
2
18.00
0.75
5.00
Maroon
10
JMTRB38-3-X
9
Three-level threaded rod bracket;
accepts 1/4" – 3/8" threaded rod.
10
HLSP1.5S-X0
2
6.00
0.75
1.50
Black
10
JMSBCB87-1-X
10
Single-level screw-on beam clamp
bracket for use with flanges up to
3/4" thick.
10
JMSBCB87-3-X
11
Three-level screw-on beam clamp
bracket for use with flanges up to
3/4" thick.
10
H.61
Order number of pieces required, in multiples of Standard Package Quantity.
HLSP3S-X0
2
12.00
0.75
3.20
Black
10
HLSP5S-X0
2
18.00
0.75
5.00
Black
10
Call 866-405-6654 or visit www.panduit.com/stronghold
H.62
Supports & Fasteners
Communications/
Low Voltage
StrongHold™ Communications/Low Voltage Part Numbers
Bridle Rings Referenced Images
Contractor Grade Hook and Loop
Cable Ties
• Strong, low-profile, flexible material that is
safe to use on high-performance cabling
• Cost-effective for general bundling
• Color: Black
Part Number
Length
(Feet)
Width
(In.)
Max.
Bundle Dia.
(In.)
Std.
Pkg.
Qty.
TTS-35R3-0
35.00
0.75
Various
1 pkg. of
3 rolls
TTS-35RX0
35.00
0.75
Various
1 pkg. of
10 rolls
TTS-75R0
75.00
0.75
Various
1 pkg. of
10 rolls
H.63
Order number of pieces required, in multiples of Standard Package Quantity.
Image 1
Image 2
Image 4
Image 5
Image 3
Call 866-405-6654 or visit www.panduit.com/stronghold
H.64
Supports & Fasteners
Communications/
Low Voltage
Bridle Rings
StrongHold™ Communications/Low Voltage Part Numbers
Bridle Rings with Saddles
• Plastic saddles allow bridle rings to be used
for communication cable
• Suitable for use in air handling spaces
• Available pre-installed or can be ordered
separately to be installed by the user
• Suitable for low-voltage cabling
• Not suitable for high-performance communication cabling
• Variety of mounting options available to support specific
application requirements
Image 1
Part Number
Image
No.
Description
Std.
Pkg.
Qty.
BR-.50-10-24
1
1/2" capacity – mounts with
10-24 threads.
100
BR-.75-10-24
1
3/4" capacity – mounts with 10-24
threads.
100
BR-1.25-10-24
1
1 1/4" capacity – mounts with
10-24 threads.
100
BR-2.0-10-24
1
2" capacity – mounts with
10-24 threads.
100
BR-1.25-1/4-20
1
1 1/4" capacity – mounts with 1/4"-20
threads.
100
BR-2.0-1/4-20
1
2" capacity – mounts with
1/4"-20 threads.
100
BR-4.0-1/4-20
1
4" capacity – mounts with
1/4"-20 threads.
50
BR-1.25-14WS
2
1 1/4" capacity – mounts with #14 wood
screw thread.
100
BR-2.0-14WS
2
2" capacity – mounts with #14 wood
screw thread.
100
BR-1.5-PAF
3
1 1/2" capacity – mounts with powder
actuated fastener.
50
BR-2.0-PAF
3
2" capacity – mounts with
powder actuated fastener.
50
BR-1.5-SN
4
1 1/2" capacity – mounts with screws,
nails, or other user supplied fasteners.
100
BR-2.0-SN
4
2" capacity – mounts with screws, nails,
or other user supplied fasteners.
100
BR-1.5-TW
5
1 1/2" capacity – mounts with
toggle screw.
25
BR-2.0-TW
5
2" capacity – mounts with toggle screw.
25
H.65
Order number of pieces required, in multiples of Standard Package Quantity.
Image 2
Part Number
Image 3
Image
No.
Description
Std.
Pkg.
Qty.
BR-1.5-1/4-20S
1
Bridle ring with saddle – 1.5" capacity
– mounts with 1/4-20 threads.
50
BR-2.0-1/4-20S
1
Bridle ring with saddle – 2" capacity –
mounts with
1/4-20 threads.
50
BR-4.0-1/4-20S
1
Bridle ring with saddle – 4" capacity –
mounts with
1/4-20 threads.
50
BR-1.5-14WSS
2
Bridle ring with saddle – 1.5" capacity – mounts with #14 wood screw
threads.
50
BR-2.0-14WSS
2
Bridle ring with saddle – 2" capacity –
mounts with #14 wood screw threads.
50
BRS-1.5
3
Saddle only for 1.5" –
diameter bridle ring.
100
BRS-2.0
3
Saddle only for 2" –
diameter bridle ring.
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.66
Supports & Fasteners
Dry Wall
Low-Voltage
Mounting Brackets
Image 1
Mount with
self-tapping screws
found on page H.49!
StrongHold™ Dry Wall Part Numbers
Old Work Box Mount
• Prevents electrical box from pulling away
from dry wall
• Supports box to dry wall to prevent
mounting directly to stud
• Allows quick installation with no
tools required
• Manufactured from pre-galvanized steel
• Choose design styles for new or
retrofit installations
• Available in both single and
double gang configurations
• Manufactured from galvanized
steel materials
Part Number
PDSI2A
Image 2
Part Number
Image 3
Image
No.
Description
Secures electrical box to dry wall.
100
Image 4
Description
Std.
Pkg.
Qty.
LV-S-1G
1
Single gang, low-voltage mounting
bracket for new installations.
25
LV-S-2G
2
Double gang, low-voltage mounting
bracket for new installations.
25
LV-W-1G
3
Single gang, low-voltage mounting
bracket for retrofit installations;
suitable for wall material
thicknesses for 1/2" – 1 1/2".
100
LV-W-2G
4
Double gang, low-voltage mounting
bracket for retrofit installations;
suitable for wall material
thicknesses for 1/2" – 1 1/2".
50
H.67
Std.
Pkg.
Qty.
Order number of pieces required, in multiples of Standard Package Quantity.
Wiring Device Retainer
• Provides stability and prevents broken
cover plates
• Manufactured from pre-galvanized steel
Part Number
PRLC
Description
Std.
Pkg.
Qty.
Mounts standard outlet or switch in oversized openings.
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.68
Supports & Fasteners
Acoustical
T-Bar Clip Top-Mount Assemblies
Troffer Fastener Clip
• Positive clip-on
support for troffers/lay-in fixtures
• Fits round or rectangular head T-bars
• Complies with NEC Article 410.36
requirements (reference pages O.11
for details)
• For upturned or straight lip fixtures
Part Number
P515A
StrongHold™ Acoustical Part Numbers
Description
T-bar clip for troffers.
Image 1
Std.
Pkg.
Qty.
100
Image 2
Image
No.
Fits
EMT
(In.)
Fits
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P8PATA
1
P12PATA
1
1/2
—
100
3/4
1/2
P16PATA
100
1
1
3/4
100
P6MATA
2
3/8*
3/8
100
P812MATA
2
1/2 – 3/4
1/2 – 3/4
100
P16MATA
2
1
1
100
Part Number
T-Bar Clip
*Or 14-2 through 12-3 MC/AC cable.
• Supports outlet boxes
above acoustical T-bar
• Top-mounted applications
• Used in conjunction with T-bar clip
top-mount assemblies to eliminate the
need for offset bending conduit
• Meets NEC Article 300.11 requirements
(reference page O.2 for details)
Part Number
PATA4I
H.69
Description
T-bar clip with 1/4-20 mounting hole.
• For supporting conduit above
acoustical T-bar
• Top-mounted applications
• Used in conjunction with T-bar clips mounted
to electrical boxes to eliminate the need for
offset bending conduit
• Meet NEC Article 300.11 requirements
(reference page O.2 for details)
Std.
Pkg.
Qty.
100
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.70
Supports & Fasteners
Acoustical
T-Bar Clip Side-Mount Assemblies
Image 1
StrongHold ™ Acoustical Part Numbers
T-Bar Drop Wire Clip
• Support conduit above acoustical T-bar
in side-mounted applications
• Used in conjunction with T-bar clips
mounted to electrical boxes to eliminate
the need for offset bending conduit
• Meets NEC Article 300.11 requirements
(reference page O.2 for details)
• Provides a means to support fixtures from
building structure instead of T-bar
• Includes 5/8" stud and wing nut washer
• Accommodates 1" T-bar
• Manufactured from
pre-galvanized materials
Part Number
PIDS
Description
T-bar drop wire clip for use with
1" T-bar.
Static Load
Rating
(Lbs.)
Std.
Pkg.
Qty.
65
50
Image 2
Image
No.
Fits
EMT
(In.)
Fits
Rigid/IMC
(In.)
Std.
Pkg.
Qty.
P8PATS
1
P12PATS
1
1/2
—
100
3/4
1/2
P16PATS
100
1
1
3/4
100
P6MATS
2
3/8*
3/8
100
P812MATS
2
1/2 – 3/4
1/2 – 3/4
100
P16MATS
2
1
1
100
Part Number
*Or 14-2 through 12-3 MC/AC cable.
T-Bar Fastener
• Provides method of attaching conduit and
electrical boxes above T-bar
• Allows secure screw attachment to T-bar
• Eliminates offset bend in conduit
Part Number
P4ACS
H.71
Order number of pieces required, in multiples of Standard Package Quantity.
Description
Conduit and box support for T-bar with 1/4-20
threaded impression.
Call 866-405-6654 or visit www.panduit.com/stronghold
Std.
Pkg.
Qty.
100
H.72
Supports & Fasteners
Acoustical
Box to T-Bar Fasteners
Image 1
StrongHold ™ Acoustical Part Numbers
Heavy Duty Adjustable Box Mounting
Bar Hangers
• Accommodate 24" T-bar span
• Non-adjustable version is suitable
for flush or offset mount
• Adjustable version provides for 8"
adjustments allowing the installation of
double deep boxes, speaker cases, and
emergency light fixtures above T-bar
P512HDK
• Box fastener adjustable for 16" – 24" ceiling
joist/stud spacing
• Allow versatility in installing electrical boxes
along the length of the bar
• Install quickly and easily between ceiling
joists or wall studs
Image 2
P512HDT
Image 3
Part Number
Image 4
Image
No.
Image 5
Description
Description
Std.
Pkg.
Qty.
P512HDK
Installs in 1/2" knockouts in bottom of electrical box.
50
P512HDT
Includes 3/4" stud to accommodate fixture stems.
50
Part Number
Std.
Pkg.
Qty.
P512
1
Box to T-bar fastener for flush or 3/4"
offset mount.
50
P512A
2
Box to T-bar fastener allows up to 8" of
height adjustment.
25
PBHC*
3
Additional box mounting
clip with screw for P512
and P512A.
100
P512HD
4
Heavy duty box to t-bar
fastener for 24” span. Includes box
mounting clip.
25
P510HD
5
Additional box mounting clip
for P512HD.
100
*Not UL or cUL listed.
H.73
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.74
Supports & Fasteners
Acoustical
T-Bar Assembly for Lighting Support
StrongHold ™ Acoustical Part Numbers
T-Bar Scissor Clips
• Accommodates fixed 24" T-bar span
• Allows for adjustable fixture position
• Fits Lightolier 5 and Calculite* series fixtures
• Support electrical fixtures or boxes to 1"
wide T-bar
• Include 1" wing nut washer (see page M.3)
• Multiple stud lengths provided
• No tools required for installation
PPT16
Part Number
P520
Std.
Pkg.
Qty.
Description
T-bar assembly that fits Lightolier 5 and Calculite*
series fixtures.
25
*Lightolier and Calculite are trademarks of the Phillips group brand.
P4G162
Part Number
Description
Std.
Pkg.
Qty.
PPT16
T-bar scissor clip with 1/4-20 x 5/8" stud.
50
P4G162
T-bar scissor clip with 1/4-20 x 2" stud.
50
Twist-On T-Bar Hanger
• Easily twists onto T-bar to support
electrical fixtures
• Accommodates T-bar 15/16" wide
• Includes 1" wing nut washer
(see page M.3)
Part Number
P4G16
H.75
Description
Twist-on T-bar hanger with 1/4-20
x 5/8" long threaded stud.
Static Load
Rating
(Lbs.)
Std.
Pkg.
Qty.
50
100
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
H.76
Supports & Fasteners
Acoustical
Independent Drop Wire Clips
PEC311
Fluorescent Light Fixture Hanger
• Prevent sway of dedicated drop wire
• Satisfy NEC Article 300.11 code
requirements (reference page O.2 for
details); consult local authority
• Yellow color provides easy identification
by inspectors
• Fits most fluorescent light fixtures
• Allows quick installation with no
tools required
• Provides an easy method to support an
industrial class fluorescent light fixture
Image 1
Image 2
PEC3114Z34
Part Number
Description
Std.
Pkg.
Qty.
PEC311
Independent drop wire clip.
100
PEC3114Z34
Independent drop wire clip with spring steel drop
wire clip.
100
H.77
StrongHold ™ Acoustical Part Numbers
Order number of pieces required, in multiples of Standard Package Quantity.
Part Number
Image
No.
Description
Std.
Pkg.
Qty.
PLFC
1
Side mount fixture clip.
100
PLFC90
2
Top mount fixture clip.
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.78
Supports & Fasteners
Miscellaneous
StrongHold ™ Miscellaneous Part Numbers
Rod Hanger for Non-Threaded Rod
Rod Hangers with Threaded Impressions
• Friction fit prevents the need for
additional hardware
• Static load capacity: 160 lbs.
• Prevent the need for additional nuts
• Include 1/4" mounting hole in top
for assemblies
• Static load capacity: 160 lbs.
Part Number
Description
Std.
Pkg.
Qty.
P4TI
Accommodates 1/4-20 threaded rod.
100
Part Number
P6TI
Accommodates 3/8-16 threaded rod.
100
P6A
Description
Std.
Pkg.
Qty.
3/8" non-threaded rod.
100
Rod Hanger for Drop Wire or
Non-Threaded Rod
• Friction fit prevents the need for
additional hardware
• Two windows provide most suitable fit for
multiple diameter wire/rod.
• Static load capacity: 160 lbs.
Part Number
P708
H.79
Order number of pieces required, in multiples of Standard Package Quantity.
Description
Std.
Pkg.
Qty.
Rod hanger for #8 wire or 1/4" plain rod.
Call 866-405-6654 or visit www.panduit.com/stronghold
100
H.80
Supports & Fasteners
Miscellaneous
Wing Nut Washer
StrongHold ™ Miscellaneous Part Numbers
Brackets
• Used in conjunction with products with
1/4-20 stud
• Manufactured from pre-galvanized steel
• Suitable to be installed by hand; no
tools required
• Not to exceed load rating of the
corresponding fastener
Part Number
P4WN
Description
Wing nut washer fits 1/4-20 stud.
PAO
Std.
Pkg.
Qty.
100
PAB
Part Number
H.81
• Utilized for assemblies or a variety
of other applications
• Prevents conduit bends to accommodate
electrical boxes
• Static load capacity: 160 lbs.
Order number of pieces required, in multiples of Standard Package Quantity.
Description
Std.
Pkg.
Qty.
PAO
Offset bracket with two 1/4"
non-threaded holes.
100
PAB
Right angle bracket with two 1/4"
non-threaded holes.
100
Call 866-405-6654 or visit www.panduit.com/stronghold
H.82
Duct Seal
Cable Ties
Panduit's duct seal is easy to use and helps to seal irregular
openings from air, dust, or water. It is also a non-corrosive and
non-toxic safe material, while providing vibration dampening.
StrongHold
Cable
TiePart
PartNumbers
Numbers
Panduit ® ™Duct
Seal
Duct Seal —
Sealing Compounds
• Seals irregular openings from air, dust, or water
• Non-hardening sealant that adheres to metal, masonry, wood or
plastic
• Provides vibration dampening
• Safe and easy to use, non-corrosive, non-toxic, no asbestos, will not
stain or harm hands, and no unpleasant odor
• Dielectric strength: 200 V/Mil, Min 0.030" thick
• Temperature range: -30°F – 210°F (-34°C – 98°C)
• 10 year minimum shelf life
• Indoor use only
Part Number
I.1
Order number of pieces required, in multiples of Standard Package Quantity.
Part Description
DS1
Duct seal (sealing compound) 1 lb. package
DS5
Duct seal (sealing compound) 5 lb. package
Std.
Pkg.
Qty.
1
Call 866-405-6654 or visit www.panduit.com/stronghold
I.2
NetKey®
Cabling System
The Keystone Copper Cabling System provides a complete
component and standards compliant cabling infrastructure
solution for voice, data and video applications.
Keystone modules feature the universal “keystone” design
and are compatible with a wide assortment of modular patch
panels, faceplates, and surface mount boxes. When combined
with complementary Panduit products, NetKey® connectivity
provides solutions from the telecommunication room to the
work area with proven innovation and quality.
NetKey ® Cabling System Part Numbers
NetKey ® Category 6A, 6 and 5e Jack Modules
� Meet all industry performance standards for Category 6A, 6 and 5e
� Punchdown jack modules are 100% performance tested and
individually serialized for future traceability
� Keystone punchdown jacks meet ANSI/TIA 568-C.2 and ISO 11801
component requirements
� Snap in and out of keystone openings for easy moves, adds and changes
� Universal label includes T568A and T568B wiring schemes
NK6X88MIW
NK688MIW
NKP5E88MIW
Part Number
Description
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
NetKey ® Category 6A UTP Jack Modules*
NK6X88MIW
Category 6A, component compliant,
8-position, 8-wire keystone
punchdown jack module.
Off
White
1
50
NK6X88MIW-Q
Convenience pack of 25, Category
6A, component compliant, 8-position,
8-wire keystone punchdown
jack modules.
Off
White
25
250
*For standard colors other than IW (Off White), replace IW in part number with
EI (Electric Ivory), IG (International Gray), WH (White), BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet).
J.1
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.2
Cabling System
NetKey®
NetKey ® Category 6A, 6 and 5e Jack Modules (continued)
NetKey ® Cabling System Part Numbers
NetKey ® Copper UTP Patch Cords
� Meets all industry performance standards for Category 6A, 6 and 5e
� 100% performance tested
� Available in a variety of colors and lengths for design flexibility
NK688MIW
NKP5E88MIW
Part Number
Description
Color
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
50
NetKey ® Category 6 UTP Jack Modules
NK688MIW
NK688MIW-Q
Category 6, component compliant,
8-position, 8-wire, keystone
punchdown jack module.
Off
White
1
Convenience pack of 25, Category
6, component compliant, 8-position,
8-wire, keystone punchdown
jack modules.
Off
White
25
250
Part Number
Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
1
10
1
10
1
10
Category 6A UTP Patch Cord
NK6APC^*
NetKey Category 5e UTP Jack Modules*
®
NKP5E88MIW
Category 5e, component compliant,
8-position, 8-wire, keystone
punchdown jack module.
Off
White
1
50
NKP5E88MIW-Q
Convenience pack of 25, Category
5e, component compliant, 8-position,
8-wire, keystone punchdown
jack modules.
Off
White
25
250
*For standard colors other than IW (Off White), replace IW in part number with
EI (Electric Ivory), IG (International Gray), WH (White), BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet).
J.3
NK5EPC^*Y
NK6APC^*
NK6PC^*Y
Order number of pieces required, in multiples of Standard Package Quantity.
Category 6A, UTP patch cord with modular
plugs on each end.
Category 6 UTP Patch Cord
NK6PC^*Y
Category 6, UTP patch cord with modular
plugs on each end.
Category 6 UTP Patch Cord
NK5EPC^*Y
Category 5e, UTP patch cord with modular
plugs on each end.
^Available in 3, 5, 7, 10, 14 and 20-foot lengths.
*For standard colors other than Off White, add suffix BU (Blue), RD (Red), YL
(Yellow) or GR (Green) before Y in the part number. For example, the part
number of a blue, Category 6, 5-foot patch cord is NK6PC5BUY.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.4
Cabling System
NetKey®
NetKey ® Keystone Patch Panels
NetKey ® Cabling System Part Numbers
NetKey ® Keystone Patch Panels (continued)
�M
ounts to standard ANSI/TIA 19" racks
�P
unchdown patch panels meet all industry performance standards for
Category 6A, 6, and 5e
�M
odular patch panels accept all NetKey® Modules
�O
ptional angeld versions available for high density installations
�O
ptional strain relief bars assist in cable management and bend radius
control
�N
ot compatible with Mini-Com® Jacks and Modules
NK6PPG12WY
NK5EPPG12WY
Part Number
NKFP12W
Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Punchdown Patch Panels - Category 6
NKA6XPPG24Y
NK6XPPG24Y
Part Number
Description
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
NK6PPG12WY
Category 6, 12-port punchdown patch panel.
Mounts to wall with standard 89D bracket
(WB89D).
1
10
NKA6PPG24Y
Category 6, 24-port, angled punchdown patch
panel, 1 RU.
1
10
NKA6PPG48Y
Category 6, 48-port, angled punchdown patch
panel, 2 RU.
1
10
Punchdown Patch Panels - Category 6A
NKA6XPPG24Y
Category 6A angled punchdown patch panel,
24 port, 1 RU.
1
10
NK6PPG24Y
Category 6, 24-port, punchdown patch panel,
1 RU.
1
10
NKA6XPPG48Y
Category 6A angled punchdown patch panel,
48 port, 2 RU.
1
10
NK6PPG48Y
Category 6, 48-port, punchdown patch panel,
2 RU.
1
10
NK6XPPG24Y
Category 6A punchdown patch panel,
24 port, 1 RU.
1
10
NK6PPG48Y
Category 6, 48-port, punchdown patch panel,
2 RU.
1
10
NK6XPPG48Y
Category 6A punchdown patch panel,
48 port, 2 RU.
1
10
Punchdown Patch Panels - Category 5e
NK5EPPG12WY
Category 5e, 12-port punchdown patch panel.
Mounts to wall with standard 89D bracket
(WB89D).
1
10
NKA5EPPG24Y
Category 5e, 24-port, angled punchdown
patch panel, 1 RU.
1
10
NKA5EPPG48Y
Category 5e, 48-port, angled punchdown
patch panel, 2 RU.
1
10
NK5EPPG24Y
Category 5e, 24-port, punchdown patch
panel, 1 RU.
1
10
NK5EPPG48Y
Category 5e, 48-port, punchdown patch
panel, 2 RU.
1
10
*Punchdown patch panels are color-coded for T568A and T568B wiring schemes.
*Punchdown patch panels are color-coded for T568A and T568B wiring schemes.
J.5
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.6
NetKey®
Cabling System
NetKey ® Keystone Patch Panels (continued)
NetKey ® Cabling System Part Numbers
NetKey ® Keystone Patch Panels (continued)
NKFP24Y
SRB19BLY
NKPPA48FMY
NKFP48Y
Part Number
WB89D
Description
Std. Std.
Pkg. Ctn.
Qty. Qty.
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Wall mount bracket. Ideal for use with 12-port
punchdown or modular patch panels.
1
10
SRB19BLY
Strain relief bar extends 2" from standard 19"
rack for additional
cable support.
1
10
SRBM19BLY
Strain relief bar and Tak-Ty ® Hook & Loop
Cable Ties for additional
cable support.
1
10
SRBS19BL-XY
Straight strain relief bar.
1
10
Part Number
NKFP12W
12-port modular patch panel with front
removable faceplate. Mounts to wall with
standard 89D bracket (WB89D).
1
10
NKFP24Y
24-port modular patch panel with front
removable faceplate, 1 RU.
1
10
NKFP48Y
48-port modular patch panel with front
removable faceplate, 2 RU.
1
10
NKPPA24FMY
24-port flush mount angled modular patch
panel, 1 RU.
1
10
NKPPA48FMY
48-port flush mount angled modular patch
panel, 2 RU.
1
10
NKPP24FMY
24-port flush mount modular patch panel,
1 RU.
1
10
NKPP48FMY
48-port flush mount modular patch panel,
2 RU.
1
10
NK6XPPG48Y
Category 6A punchdown patch panel,
48 port, 2 RU.
1
10
Description
Wall Mount Bracket
WB89D
Modular Patch Panels
SRBM19BLY
Strain Relief Bars
*Punchdown patch panels are color-coded for T568A and T568B wiring schemes.
*Punchdown patch panels are color-coded for T568A and T568B wiring schemes.
J.7
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.8
Cabling System
NetKey®
NetKey ® Cabling System Part Numbers
NetKey ® Keystone Faceplates
NetKey ® Snap-On Sloped Keystone Faceplates
�M
ounts to standard ANSI/TIA 19" racks
� Accept all Panduit ® NetKey ® Keystone Copper Modules and Duplex
Fiber Optic Modules
�P
unchdown patch panels meet all industry performance standards for
Category 6A, 6, and 5e
�M
odular patch panels accept all NetKey® Modules
� Snap into raceway channel, requires no additional mounting hardware
or adapters - greatly reducing installation time
� Modular patch panels accept all NetKey® Modules
�O
ptional angeld versions available for high density installations
�O
ptional strain relief bars assist in cable management and bend radius
control
� Lowest cost for moves, adds, and changes
�N
ot compatible with Mini-Com® Jacks and Modules
�C
an be used with Pan-Way ® Cove, TG-70, T70, Twin-70, T-45
Raceway Systems, Fast-Snap™ Outlet Boxes, and Pan-Pole™
Aluminum Outlet Poles
NK2FNIW
NK2FIWY
Part Number
NK2HSFIWY
NK4VSFIWY
Description
� Tamper resistant
NKF2S
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
1
10
NK2HSRF
NK4HSRF
NK4VSRF
Flush Mount Screw-On Faceplates
NK*FNIW
Single gang, flush mount vertical faceplate.
NK**FIWY
Single or double gang, flush mount vertical
faceplate
with labels.
1
10
NK^HSFIWY
Single gang, sloped, horizontal faceplate with
labels.
1
10
Single gang, 4-port, sloped, vertical faceplate
with labels.
1
10
1
10
NK4VSF
Part Number
NK2HSRFIW
Snap‑On 2-position sloped horizontal
faceplate accepts any Panduit ® NetKey ®
Module. Compatible with Panduit ® NetKey ®
Outlet Boxes, Surface Raceway Systems,
and Pan‑Pole™ Outlet Poles.
Off
White
1
10
NK4HSRFIW
Snap‑On 4-position sloped horizontal
faceplate accepts any Panduit ® NetKey ®
Module. Compatible with Panduit ® NetKey ®
Outlet Boxes, Surface Raceway Systems,
and Pan‑Pole™ Outlet Poles.
Off
White
1
10
NK4VSRFIW
Snap‑On 4-position sloped vertical faceplate
accepts any Panduit ® NetKey ® Module.
Compatible with Panduit ® NetKey ® Outlet
Boxes, Surface Raceway Systems, and
Pan‑Pole™ Outlet Poles.
Off
White
1
10
Stainless Steel Faceplates
NKF^^S
Single gang, stainless steel, vertical faceplate
with labels.
Description
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
Panduit ® NetKey ® faceplates are NOT compatible with Panduit ® Mini‑Com ® Modules.
‡For other colors replace IW (Off White) with EI (Electric Ivory), IG (International Gray), or
WH (White).
For complete labeling solutions refer to www.panduit.com.
J.9
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.10
Cabling System
NetKey®
NetKey ® Cabling System Part Numbers
NetKey ® Keystone Module Frame and Furniture Faceplates
NetKey ® Snap-On Flush Universal
Keystone Faceplates
�W
ider module spacing to accept common manufacturers' keystone
modules 0.900 inches wide or less
�C
an be used with Pan-Way ® Cove, TG-70, T70, Twin-70, T-45
Raceway Systems, Fast-Snap™ Outlet Boxes, and Pan-Pole™
Aluminum Outlet Poles
NK2106MFIW
Part Number
T70KW2IW
T70KW4IW
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
Part Number
Description
T70KW2IW
Snap‑On 2-position flush mount faceplate
accepts any Panduit ® NetKey ® Module and
most other manufacturers’ keystone modules.
Compatible with Panduit ® Fast-Snap™ Outlet
Boxes, Surface Raceway Systems, and
Pan‑Pole™ Outlet Poles.
Off
White
Snap‑On 4-position flush mount faceplate
accepts any Panduit ® NetKey ® Module and
most other manufacturers’ keystone modules.
Compatible with Panduit ® Fast-Snap™ Outlet
Boxes, Surface Raceway Systems, and
Pan‑Pole™ Outlet Poles.
Off
White
T70KW4IW
1
1
10
J.11
®
®
®
Order number of pieces required, in multiples of Standard Package Quantity.
NK2RMFIW
NK4RMFIW
Description
NK4MFIW
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
NK2106MFIW
Screw mount “106” duplex module frame.
Accepts two NetKey ® Modules.
Off
White
1
10
NK4106MFIW
Screw mount “106” duplex module frame.
Accepts four NetKey ® Modules.
Off
White
1
10
NK2RMFIW
Screw mount module frame. Accepts
two NetKey ® Modules. Compatible
with standard NEMA outlet boxes and
rectangular faceplates.
Off
White
1
10
NK4RMFIW
Screw mount module frame. Accepts
four NetKey ® Modules. Compatible
with standard NEMA outlet boxes and
rectangular faceplates.
Off
White
1
10
NK4MFIW
Snap on modular furniture faceplate.
Accepts four NetKey ® Modules.
Off
White
1
10
10
Panduit NetKey faceplates are NOT compatible with Panduit Mini‑Com Modules.
‡For other colors replace IW (Off White) in part number with EI (Electric Ivory), IG
(International Gray), or WH (White).
For complete labeling solutions refer to www.panduit.com.
®
NK4106MFIW
‡For standard colors other than Off White, replace IW in part number with
EI (Electric Ivory), WH (White), IG (International Gray) or BL (Black).
Call 866-405-6654 or visit www.panduit.com/stronghold
J.12
Cabling System
NetKey®
NetKey ® Cabling System Part Numbers
NetKey ® Keystone Surface Mount Boxes
Keystone Phone Plates
� Accepts all Panduit ® NetKey ® Modules
� Includes mounting screws and adhesive tap
� Compatible with Panduit ® LE3, SD5, and LD10 Raceway
� Not Compatible with Mini-Com ® Jacks and Modules
KWPY
Part Number
KWP3Y
Description
Std. Std.
Pkg. Ctn.
Qty. Qty.
KWPY
Stainless steel wall phone plate accepts one module.
1
10
KWP3Y
Stainless steel wall phone plate supplied with one
Category 3 keystone leadframe module.
1
10
Wall mount faceplate kits compatible with wall mountable phones with short
patch cord connections to the jack module.
NK2BXIW-A
Part Number
NK4BXIW-AY
NK6BXIW-AY
Description
CBM-X
Std. Std.
Pkg. Ctn.
Color‡ Qty. Qty.
NK2106MFIW
Screw mount “106” duplex module frame.
Accepts two NetKey ® Modules.
Off
White
1
10
NK4106MFIW
Screw mount “106” duplex module frame.
Accepts four NetKey ® Modules.
Off
White
1
10
NK2RMFIW
Screw mount module frame. Accepts
two NetKey ® Modules. Compatible
with standard NEMA outlet boxes and
rectangular faceplates.
Off
White
1
10
NK4RMFIW
Screw mount module frame. Accepts
four NetKey ® Modules. Compatible
with standard NEMA outlet boxes and
rectangular faceplates.
Off
White
1
10
NK4MFIW
Snap on modular furniture faceplate.
Accepts four NetKey ® Modules.
Off
White
1
10
‡For surface mount box standard colors other than IW (Off White), replace
suffix with EI (Electric Ivory), IG (International Gray) or WH (White).
J.13
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.14
Cabling System
NetKey®
Termination Tool
NetKey ® Audio/Video Modules
NKFIW
NKBNCMIWY
Part Number
NKHDMIIW
NKUSBAAIW
Description
NKBMIW-X
Color‡
Std.
Pkg.
Qty.
Std.
Ctn.
Qty.
Part Number
Description
Std. Std.
Pkg. Ctn.
Qty. Qty.
F-Type Module
F-Type Module
NKFIW
NetKey ® Cabling System Part Numbers
Off
White
1
10
Keystone module supplied with 50
ohm industry standard coax bulkhead
coupler.
Off
White
1
10
Keystone module supplied with one
HDMI 1.3 Type A female to female
coupler module.
Off
White
1
10
Keystone module supplied with
one USB 2.0 female A to female A
coupler module.
Off
White
1
10
Blank keystone module reserves
space for future use.
Off
White
1
10
Keystone module supplied with 75
ohm industry standard F-Type coax
bulkhead coupler.
NKSPB
Base used to assist in terminating keystone
punchdown modules.
1
10
50 Ohm BNC Coax Module
NKBNCMIWY
HDMI Coupler
NKHDMIIW
USB Coupler
NKUSBAAIW
Blank Module
NKBMIW-X
‡For standard colors other than IW (Off White), replace IW in part number with
EI (Electric Ivory), WH (White), IG (International Gray) or BL (Black). 5-Way
Binding Post Module (NKBP^IWY ) only available in EI (Electric Ivory) and
WH (White).
J.15
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
J.16
Convenient
Sizing Information
Rigid Steel Conduit
Electrical Metallic Tubing (EMT)
Min. Weight Per 100 Ft.
w/ Couplings
Attached (Lbs.)
Weight of
Conduit and
Conductors
Per 100 Ft.
(Lbs.)
0.58
23.00
0.71
28.50
0.82
0.92
1.05
1.16
Trade
Size
(In.)
Nominal
Inside
Dia.*
(In.)
Nominal
Outside
Dia.
(In.)
0.38
0.49
0.50
0.62
0.75
1.00
1.25
1.38
1.51
StrongHold ™ Convenient Sizing Information
Weight of
Conduit and
Conductors
Per 100 Ft.
(Lbs.)
Trade
Size
(In.)
Nominal
Inside
Dia.*
(In.)
Nominal
Outside
Dia.
(In.)
Min. Weight
Per 100 Ft. w/
Couplings
Attached (Lbs.)
36.60
0.38
0.49
0.68
51.50
65.10
50.60
0.50
0.63
0.84
79.00
101.00
43.50
84.30
0.75
0.84
1.05
105.00
145.80
64.00
130.30
1.00
1.06
1.32
153.00
219.30
212.30
1.25
1.39
1.66
201.00
318.30
1.62
1.90
249.00
408.80
593.80
95.00
1.50
1.61
1.74
110.00
269.80
1.50
2.00
2.07
2.20
140.00
401.80
2.00
2.08
2.38
332.00
2.50
2.73
2.88
205.00
579.00
2.50
2.49
2.88
527.00
901.00
3.00
3.36
3.50
250.00
826.30
3.00
3.09
3.50
682.60
1259.00
3.50
3.83
4.00
325.00
1098.00
3.50
3.57
4.00
831.00
1604.00
1364.00
4.00
4.05
4.50
972.30
1967.00
Trade Size
(In.)
Nominal
Inside
Dia.*
(In.)
Nominal
Outside
Dia.
(In.)
Min. Weight
Per 100 Ft. w/
Couplings
Attached (Lbs.)
Weight of
Conduit and
Conductors
Per 100 Ft.
(Lbs.)
0.50
0.63
0.84
27.40
49.50
0.75
0.84
1.05
36.40
77.20
1.00
1.06
1.32
53.00
119.30
1.25
1.39
1.66
69.60
186.90
1.50
1.62
1.90
82.20
242.00
2.00
2.08
2.38
115.70
377.50
2.50
2.49
2.88
182.50
556.50
3.00
3.09
3.50
238.90
815.20
3.50
3.57
4.00
287.70
1061.00
4.00
4.05
4.50
340.00
1334.00
5.00
5.07
5.56
465.40
2028.00
6.00
6.09
6.63
612.50
2870.00
4.00
4.33
4.50
370.00
*Per UL table NAE.3.
*Per UL table NAE.3.
Intermediate Metal Conduit (IMC)
Rigid Aluminum Conduit
Trade
Size
(In.)
Nominal
Inside
Dia.*
(In.)
Nominal
Outside
Dia.
(In.)
Min. Weight Per 100
Ft. w/ Couplings
Attached (Lbs.)
Weight of
Conduit and
Conductors
Per 100 Ft.
(Lbs.)
0.50
0.68
0.82
60.00
82.10
0.75
0.88
1.03
82.00
122.80
1.00
1.12
1.29
116.00
182.30
1.25
1.47
1.64
150.00
267.30
1.50
1.70
1.88
182.00
341.80
2.00
2.17
2.36
242.00
503.80
2.50
2.60
2.86
401.00
775.00
3.00
3.22
3.48
493.00
1069.00
3.50
3.71
3.97
573.00
1346.00
4.00
4.21
4.47
638.00
1632.00
*Per UL table NAE.3.
*Per UL table NAE.3.
K.1
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
K.2
Convenient
Sizing Information
Electrical Non-Metallic Tubing (ENT)
StrongHold ™ Convenient Sizing Information
MC Cable
Min. Weight of
Conduit Per 100
Ft. (Lbs.)
Weight of
Conduit and
Conductors
Per 100 Ft.
(Lbs.)
AWG
Size
Insulated Ground
Nominal
Outside Dia.
(In.)
Bare Ground
Nominal
Outside Dia.
(In.)
0.84
11.00
33.10
14-2 Solid
0.45
0.43
14-3 Solid
0.48
0.76
1.05
14.00
0.44
54.80
14-4 Solid
0.51
1.00
1.00
1.32
0.49
20.00
86.30
12-2 Solid
0.50
1.25
1.40
0.47
1.66
19.00
136.30
12-3 Solid
0.53
1.50
0.50
1.55
1.99
27.00
186.80
12-4 Solid
0.57
2.00
0.56
2.03
2.38
32.00
261.80
10-2 Solid
0.56
0.52
10-3 Solid
0.60
0.55
10-4 Solid
0.65
0.62
8-2 Stranded
0.71
0.68
8-3 Stranded
0.77
0.71
8-4 Stranded
0.84
0.77
6-2 Stranded
0.80
0.76
6-3 Stranded
0.87
0.80
Trade
Nominal
Size
(In.)
Nominal
Inside
Dia.*
(In.)
Nominal
Outside
Dia.
(In.)
0.50
0.56
0.75
*Per UL table NAE.3.
Schedule 40 PVC Plastic Pipe
Nominal Pipe
Size
(In.)
Outside
Dia.
(In.)
Wall Thickness
(In.)
Weight
of Pipe
Per Ft.
(Lbs.)
Weight
of Water
Per Ft.
(Lbs.)
0.13
0.41
0.07
0.04
0.02
6-4 Stranded
0.95
0.87
0.25
0.54
0.09
0.07
0.04
4-2 Stranded
0.95
0.90
0.38
0.68
0.09
0.10
0.08
4-3 Stranded
1.04
0.95
0.50
0.84
0.11
0.15
0.1
4-4 Stranded
1.14
0.10
0.75
1.05
0.11
0.20
0.20
2-2 Stranded
1.08
0.10
1.00
1.32
0.13
0.30
0.40
2-3 Stranded
1.18
1.08
1.25
1.66
0.14
0.40
0.60
2-4 Stranded
1.30
1.18
1.50
1.90
0.15
0.50
0.90
2.00
2.38
0.15
0.60
1.40
2.50
2.88
0.20
1.00
2.10
3.00
3.50
0.22
1.30
3.20
3.50
4.00
0.23
1.60
4.30
4.00
4.50
0.24
1.90
5.50
All Threaded Rod (ATR)
K.3
Design Load
SF = 5
Nominal
Size
and
Thread
In.2
cm2
Lbs.
kN
1/4-20
0.03
0.17
240.00
1.07
5/16-18
0.05
0.29
400.00
1.78
3/8-16
0.07
0.44
610.00
2.71
Root Area
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
K.4
Convenient
Sizing Information
Type NM – Non-Metallic Sheathed Cable
1.23
1.07
0.88
0.76
—
—
—
—
1.12
—
—
0.97
—
—
0.81
—
0.71
0.70
0.65
0.59
—
0.54
0.55
—
0.52
Stranded
Solid
0.52
—
Stranded
Ground
Wire
Size
Approximate
Outside
Dia.
(In.)
Approximate
Weight
Per 100 Ft.
(Lbs.)
Without Ground Wire
0.49
Solid
AWG
Size
No.
of
Strands
14-2
Solid
—
0.17 x 0.37
5.30
12-2
Solid
—
0.19 x 0.40
7.00
10.10
10-2
Solid
—
0.22 x 0.45
14-3
Solid
—
0.30
8.20
12-3
Solid
—
0.33
10.90
10-3
Solid
—
0.40
15.70
8-3
7
—
0.54
27.80
6-3
7
—
0.61
42.20
1.01
—
0.96
—
14-2
Solid
14
0.17 x 0.37
6.40
12-2
Solid
12
0.19 x 0.41
9.00
10-2
Solid
10
0.22 x 0.49
13.30
8-2
7
10
0.28 x 0.61
21.50
6-2
7
10
0.32 x 0.73
31.30
14-3
Solid
14
0.32
9.30
12-3
Solid
12
0.36
12.90
10-3
Solid
10
0.44
18.70
14-4
Solid
14
0.45
11.60
12-4
Solid
12
0.49
16.10
10-4
Solid
10
0.55
23.30
8-3
7
10
0.55
30.50
6-3
7
10
0.61
45.00
4-3
7
8
0.82
66.40
2-3
7
8
0.95
93.00
2
0.89
—
0.84
—
4
0.74
—
0.70
—
6
0.64
0.60
0.60
0.57
THHN
ACTMM
8
—
0.50
—
0.48
10
—
0.49
—
0.48
12
—
0.45
Solid
Stranded
—
0.43
Solid
Type of Circuit
Conductors
Type of Armored Cable
14
Stranded
With Ground Wire
AWG Size of Circuit Conductors
Cable with Two Circuit
Conductors and No
Grounding Conductor
(In.)
Cable with Three
Circuit Conductors and No
Grounding
Conductor, and Cable with
Two Circuit Conductors
and a Grounding
Conductor
(In.)
Minimum External Diameter of Armor
Cable with Four
Circuit Conductors and
No Grounding
Conductor, and Cable
with Three Circuit Conductors and a Grounding
Conductor
(In.)
Cable with
Four Circuit
Conductors and a
Grounding
Conductor
(In.)
AC Cable
K.5
StrongHold ™ Convenient Sizing Information
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
K.6
Convenient
Sizing Information
Type THHN – Insulated Single Conductor Building Wire
StrongHold ™ Convenient Sizing Information
Communication Cable
Size
(AWG)
Armor Outside
Dia.
(In.)
Approximate
Weight
Per 100 Ft.
(Lbs.)
Cable
Type
Diameter
(In.)
Category 6A
0.300
14
0.11
1.70
Category 6A (SD)
0.240
12
0.13
2.50
Category 6
0.240
10
0.16
4.00
Category 5e
0.225
8
0.22
6.50
6
0.25
9.70
4
0.32
15.50
3
0.35
19.10
2
0.38
23.60
1
0.45
30.40
1/0
0.49
37.50
J-Pro™ Capacity
J-Pro™
Family
Category
6A
(0.300")
Category
6A (SD)
(0.240")
Category
6
(0.240")
Category
5e
(0.225")
JP75
5
8
8
10
JP131
15
25
25
29
JP2
30
46
46
55
JP4
115
180
180
200
Note: The above cable diameters represent the nominal Panduit cable diameter
per performance level. For specific cable fill information based on specific part
numbers, please contact customer service.
K.7
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
K.8
Codes and
Standards
NFPA 70; National Electric Code; 2014 Revision
90.4 Enforcement. This Code is intended to be suitable for
mandatory application by governmental bodies that exercise
legal jurisdiction over electrical installations, including signaling and
communications systems, and for use by insurance inspectors. The
authority having jurisdiction for enforcement of the Code has the
responsibility for making interpretations of the rules, for deciding on
the approval of equipment and materials, and for granting the special
permission contemplated in a number of the rules.
By special permission, the authority having jurisdiction may waive
specific requirements in this Code or permit alternative methods
where it is assured that equivalent objectives can be achieved by
establishing and maintaining effective safety.
This Code may require new products, constructions, or
materials that may not yet be available at the time the Code
is adopted. In such event, the authority having jurisdiction
may permit the use of the products, constructions, or materials
that comply with the most recent previous edition of this Code
adopted by the jurisdiction.
300.4 Protection Against Physical Damage.
(B) Nonmetallic-Sheathed Cables and Electrical Nonmetallic
Tubing through Metal Framing Members.
(1) Nonmetallic-Sheathed Cable. In both exposed and concealed
locations where nonmetallic-sheathed cables pass through either
factory- or field-punched, cut, or drilled slots or holes in metal
members, the cable shall be protected by listed bushings or listed
grommets covering all metal edges that are securely fastened in
the opening prior to installation of the cable.
(D) Cables and Raceways Parallel to Framing Members
and Furring Strips. In both exposed and concealed locations,
where a cable- or raceway-type wiring method is installed parallel
to framing members, such as joists, rafters, or studs, or is installed
parallel to furring strips, the cable or raceway shall be installed
and supported so that the nearest outside surface of the cable or
raceway is not less than 32mm (1 1⁄4 in.) from the nearest edge of
the framing member or furring strips where nails or screws are likely
to penetrate. Where this distance cannot be maintained, the cable or
raceway shall be protected from penetration by nails or screws by a
steel plate, sleeve, or equivalent at least 1.6mm (1⁄16 in.) thick.
Exception No. 1: Steel plates, sleeves, or the equivalent shall not
be required to protect rigid metal conduit, intermediate metal
conduit, rigid nonmetallic conduit, or electrical metallic tubing.
Exception No. 2: For concealed work in finished buildings,
or finished panels for prefabricated buildings where such
supporting is impracticable, it shall be permissible to fish the
cables between access points.
Exception No. 3: A listed and marked steel plate less than
1.6mm (1⁄16 in.) thick that provides equal or better protection
against nail or screw penetration shall be permitted.
L.1
Order number of pieces required, in multiples of Standard Package Quantity.
StrongHold ™ Codes and Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
300.11 Securing and Supporting.
(A) Secured in Place. Raceways, cable assemblies, boxes,
cabinets, and fittings shall be securely fastened in place.
Support wires that do not provide secure support shall not
be permitted as the sole support. Support wires and associated
fittings that provide secure support and that are installed in addition
to the ceiling grid support wires shall be permitted as the sole
support. Where independent support wires are used, they shall be
secured at both ends. Cables and raceways shall not be supported
by ceiling grids.
(1) Fire-Rated Assemblies. Wiring located within the cavity of a
fire-rated floor-ceiling or roof-ceiling assembly shall not be
secured to, or supported by, the ceiling assembly, including the
ceiling support wires. An independent means of secure support
shall be provided and shall be permitted to be attached to the
assembly. Where independent support wires are used, they shall
be distinguishable by color, tagging, or other effective means from
those that are part of the fire-rated design.
Exception: The ceiling support system shall be permitted
to support wiring and equipment that have been tested as
part of the fire-rated assembly.
Informational Note: One method of determining fire rating
is testing in accordance with ANSI/ASTM E119-2012a, Method for
Fire Tests of Building Construction and Materials.
(2) Non-Fire-Rated Assemblies. Wiring located within the cavity
of a non-fire-rated floor-ceiling or roof-ceiling assembly shall not
be secured to, or supported by, the ceiling assembly, including the
ceiling support wires. An independent means of secure support
shall be provided and shall be permitted to be attached to the
assembly. Where independent support wires are used, they shall
be distinguishable by color, tagging, or other effective means.
Exception: The ceiling support system shall be permitted
to support branch-circuit wiring and associated equipment
where installed in accordance with the ceiling system
manufacturer’s instructions.
300.22 Wiring in Ducts not used for Air Handling, Fabricated
Ducts for Environmental Air, and other Spaces for Environmental
Air (Plenums). The provisions of this section shall apply to the
installation and uses of electrical wiring and equipment in ducts
used for dust, loose stock, or vapor removal; ducts specifically
fabricated for environmental air; and other spaces used for
environmental air (plenums).
Informational Note: See Article 424, Part VI, for duct heaters.
(A) Ducts for Dust, Loose Stock, or Vapor Removal. No wiring
systems of any type shall be installed in ducts used to transport
dust, loose stock, or flammable vapors. No wiring system of any
type shall be installed in any duct, or shaft containing only such
ducts, used for vapor removal or for ventilation of commercial-type
cooking equipment.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.2
Codes and
Standards
L.3
StrongHold ™ Codes and Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
NFPA 70; National Electric Code; 2014 Revision
(continued)
(B) Ducts Specifically Fabricated for Environmental Air.
Equipment, devices and the wiring methods specified in this section
shall be permitted within such ducts only if necessary for the direct
action upon, or sensing of, the contained air. Where equipment or
devices are installed and illumination is necessary to facilitation
maintenance and repair, enclosed gasketed-type luminaires shall
be permitted.
Only wiring methods consisting of Type MI cable without an overall
nonmetallic covering, Type MC cable employing a smooth or
corrugated impervious metal sheath without an overall nonmetallic
covering, electrical metallic tubing, flexible metallic tubing,
intermediate metal conduit, or rigid metal conduit without an
overall nonmetallic covering shall be installed in ducts specifically
fabricated to transport environmental air. Flexible metal conduit
shall be permitted, in lengths not to exceed 1.2m (4 ft.), to connect
physically adjustable equipment and devices permitted to be in these
fabricated ducts. The connectors used with flexible metal conduit
shall effectively close any openings in the connection.
C) Other Spaces Used for Environmental Air (Plenums).
This section shall apply to spaces not specifically fabricated for
environmental air-handling purposes but used for air-handling
purposes as a plenum. This section shall not apply to habitable
rooms or areas of buildings, the prime purpose of which is not
air handling.
Informational Note No. 1: The space over a hung ceiling
used for environmental air-handling purposes is an example
of the type of other space to which this section applies.
Informational Note No. 2: The phrase “Other Spaces Used for
Environmental Air (Plenum)” as used in this section correlates with
the use of the term “plenum” in NFPA 90A-2012, Standard for the
Installation of Air-Conditioning and Ventilating Systems, and other
mechanical codes where the plenum is used for return air purposes,
as well as some other air-handling spaces.
Exception: This section shall not apply to the joist or stud spaces
of dwelling units where the wiring passes through such spaces
perpendicular to the long dimension of such spaces.
(1) Wiring Methods. The wiring methods for such other space
shall be limited to totally enclosed, nonventilated, insulated
busway having no provisions for plug-in connections, Type MI
cable without an overall nonmetallic covering, Type MC cable
without an overall nonmetallic covering, Type AC cable, or other
factory-assembled multiconductor control or power cable that is
specifically listed for use within an air-handling space, or listed
prefabricated cable assemblies of metallic manufactured wiring
systems without nonmetallic sheath. Other types of cables,
conductors, and raceways shall be permitted to be installed in
electrical metallic tubing, flexible metallic tubing, intermediate
metal conduit, rigid metal conduit without an overall nonmetallic
covering, flexible metal conduit, or, where accessible, surface
metal raceway or metal wireway with metal covers. Nonmetallic
cable ties and other nonmetallic cable accessories used to secure
and support cables shall be listed as having low smoke and heat
release properties.
Informational Note: One method to determine low smoke and
heat release properties is that the nonmetallic cable ties and other
nonmetallic cable accessories exhibit a maximum peak optical
density of 0.50 or less, an average optical density of 0.15 or less,
and a peak heat release rate of 100kW or less when tested in
accordance with ANSI/UL 2043-2008, Fire Test for Heat and Visible
Smoke Release for Discrete Products and Their Accessories Installed
in Air-Handling Spaces.
2) Cable Tray Systems. The provisions in (a) or (b) shall apply to
the use of metallic cable tray systems in other spaces used for
environmental air (plenums), where accessible, as follows:
(a) Metal Cable Tray Systems. Metal cable tray systems shall be
permitted to support the wiring methods in 300.22 (C)(1).
(b) Solid Side and Bottom Metal Cable Tray Systems.
Solid side and bottom metal cable tray systems with solid metal
covers shall be permitted to enclose wiring methods and cables,
not already covered in 300.22 (C)(1), in accordance with 392.10 (A)
and (B).
(3) Equipment. Electrical equipment with a metal enclosure, or
electrical equipment with a nonmetallic enclosure listed for use
within an air-handling space and having adequate fire-resistant
and low-smoke-producing characteristics, and associated wiring
material suitable for the ambient temperature shall be permitted to
be installed in such other space unless prohibited elsewhere in
this Code.
Informational Note: One method of defining adequate fire-resistant
and low-smoke producing characteristics for electrical equipment
with a nonmetallic enclosure is in ANSI/UL 2043-2008, Fire Test
for Heat and Visible Smoke Release for Discrete Products and Their
Accessories Installed in Air-Handling Spaces.
Exception: Integral fan systems shall be permitted where specifically
identified for use within an air-handling space.
(D) Information Technology Equipment. Electrical wiring in
air-handling areas beneath raised floors for information technology
equipment shall be permitted in accordance with Article 645.
Order number of pieces required, in multiples of Standard Package Quantity.
310.15 Ampacities for Conductors Rated 0–2000 Volts.
(B) Tables…
(3) Adjustment Factors.
(a) More Than Three Current-Carrying Conductors. Where the number
of current-carrying conductors in a raceway or cable exceeds three,
or where single conductors or multiconductor cables are installed
without maintaining spacing for a continuous length longer than
600mm (24 in.) and are not installed in raceways, the allowable
ampacity of each conductor shall be reduced as shown in Table
310.15 (B)(3)(a). Each current-carrying conductor of a paralleled set of
conductors shall be counted as a current-carrying conductor.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.4
Codes and
Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
NFPA 70; National Electric Code; 2014 Revision
(continued)
Where conductors of different systems, as provided in 300.3, are
installed in a common raceway or cable, the adjustment factors
shown in Table 310.15 (B)(3)(a) shall apply only to the number of
power and lighting conductors (Articles 210, 215, 220, and 230).
Informational Note No. 1: See Annex B, for adjustment factors for
more than three current-carrying conductors in a raceway or cable
with load diversity.
Informational Note No. 2: See 366.23 (A) for adjustment factors
for conductors in sheet metal auxiliary gutters and 376.22 (B) for
adjustment factors for conductors in metal wireways.
(4) Adjustment factors shall not apply to Type AC cable or to Type
MC cable under the following conditions:
a. The cables do not have an overall outer jacket.
b. Each cable has not more than three current-carrying conductors.
c. The conductors are 12 AWG copper.
d. Not more than 20 current-carrying conductors are installed without
maintaining spacing, are stacked, or are supported on “bridle rings.”
(5) An adjustment factor of 60 percent shall be applied to Type AC
cable or Type MC cable under the following conditions:
a. The cables do not have an overall outer jacket.
b. The number of current carrying conductors exceeds 20.
c. The cables are stacked or bundled longer that 600mm (24 in.)
without spacing being maintained.
a lampholder, or other equipment and is supported by entering
raceways shall not exceed 1650cm3 (100 in.3) in size. It shall have
threaded entries or identified hubs. It shall be supported by two or
more conduits threaded wrenchtight into the enclosure or hubs. Each
conduit shall be secured within 900mm (3 ft.) of the enclosure, or
within 450mm (18 in.) of the enclosure if all conduit entries are on the
same side.
Exception: The following wiring methods shall be permitted to support a
conduit body of any size, including a conduit body constructed with only
one conduit entry, provided that the trade size of the conduit body is not
larger than the largest trade size of the conduit or tubing:
(1) Intermediate metal conduit, Type IMC
(2) Rigid metal conduit, Type RMC
(3) Rigid polyvinyl chloride conduit, Type PVC
(4) Reinforced thermosetting resin conduit, Type RTRC
(5) Electrical metallic tubing, Type EMT
(F) Raceway-Supported Enclosures, with Devices, Luminaires,
or Lampholders. An enclosure that contains a device(s), other
than splicing devices, or supports a luminaire(s), a lampholder, or
other equipment and is supported by entering raceways shall not
exceed 1650cm3 (100 in.3) in size. It shall have threaded entries
or identified hubs. It shall be supported by two or more conduits
threaded wrenchtight into the enclosure or hubs. Each conduit shall
be secured within 450mm (18 in.) of the enclosure.
Exception No. 1: Rigid metal or intermediate metal conduit shall be
permitted to support a conduit body of any size, including a conduit
body constructed with only one conduit entry, provided the trade size of
the conduit body is not larger than the largest trade size of
the conduit.
Exception No. 2: An unbroken length(s) of rigid or intermediate
metal conduit shall be permitted to support a box used for luminaire or
lampholder support, or to support a wiring enclosure that is an integral
part of a luminaire and used in lieu of a box in accordance with 300.15
(B), where all of the following conditions are met:
(a) The conduit is securely fastened at a point so that the length of
conduit beyond the last point of conduit support does not exceed
900mm (3 ft.).
(b) The unbroken conduit length before the last point of conduit support
is 300mm (12 in.) or greater, and that portion of the conduit is securely
fastened at some point not less than 300mm (12 in.) from its last point
of support.
(c) Where accessible to unqualified persons, the luminaire or lampholder,
measured to its lowest point, is at least 2.5m (8 ft.) above grade or
standing area and at least 900mm (3 ft.) measured horizontally to the
2.5m (8 ft.) elevation from windows, doors, porches, fire escapes, or
similar locations.
(d) A luminaire supported by a single conduit does not exceed
300mm (12 in.) in any direction from the point of conduit entry.
(e) The weight supported by any single conduit does not exceed
9 kg (20 lbs.).
314.23 Supports. Enclosures within the scope of this article shall
be supported in accordance with one or more of the provisions in
314.23 (A) through (H).
(C) Mounting in Finished Surfaces. An enclosure mounted in a
finished surface shall be rigidly secured thereto by clamps, anchors,
or fittings identified for the application.
(D) Suspended Ceilings. An enclosure mounted to structural or
supporting elements of a suspended ceiling shall be not more than
1650cm3 (100 in.3) in size and shall be securely fastened in place in
accordance with either (D)(1) or (D)(2).
(1) Framing Members. An enclosure shall be fastened to the
framing members by mechanical means such as bolts, screws, or
rivets, or by the use of clips or other securing means identified for
use with the type of ceiling framing member(s) and enclosure(s)
employed. The framing members shall be supported in an
approved manner and securely fastened to each other and to the
building structure.
2) Support Wires. The installation shall comply with the provisions
of 300.11 (A). The enclosure shall be secured, using identified
methods, to ceiling support wire(s), including any additional
support wire(s) installed for ceiling support. Support wire(s) used
for enclosure support shall be fastened at each end so as to be
taut within the ceiling cavity.
(E) Raceway Supported Enclosure, without Devices,
Luminaires, or Lampholders. An enclosure that does not contain
a device(s), other than splicing devices, or supports a luminaire(s),
L.5
StrongHold ™ Codes and Standards
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.6
Codes and
Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
NFPA 70; National Electric Code; 2014 Revision
(continued)
(f) At the luminaire or lampholder end, the conduit(s) is threaded
wrenchtight into the box, conduit body, integral wiring enclosure,
or identified hubs. Where a box or conduit body is used for support,
the luminaire shall be secured directly to the box or conduit body, or
through a threaded conduit nipple not over 75mm (3 in.) long.
Type MC cable shall be protected in accordance with 300.4 (A),
(C), and (D) where installed through or parallel to framing members.
314.27 Outlet Boxes.
(A) Boxes at Luminaire or Lampholder Outlets. Outlet boxes or
fittings designed for the support of luminaires and lampholders,
and installed as required by 314.23, shall be permitted to support a
luminaire or lampholder.
(2) Ceiling Outlets. At every outlet used exclusively for lighting,
the box shall be designed or installed so that a luminaire or
lampholder may be attached. Boxes shall be required to support
a luminaire weighing a minimum of 23 kg (50 lbs.). A luminaire that
weighs more than 23 kg (50 lbs.) shall be supported independently
of the outlet box, unless the outlet box is listed and marked on the
interior of the box to indicate the maximum weight the box shall be
permitted to support.
320.2 Definition.
Armored Cable, Type AC.
A fabricated assembly of insulated conductors in a flexible
interlocked metallic armor. See 320.100.
320.17 Through or Parallel to Framing Members. Type AC cable
shall be protected in accordance with 300.4 (A), (C), and (D) where
installed through or parallel to framing members.
320.30 Securing and Supporting.
(A) General. Type AC cable shall be supported and secured by
staples, cable ties, straps, hangers, or similar fittings, designed and
installed so as not to damage the cable.
(B) Securing. Unless otherwise permitted, Type AC cable shall be
secured within 300mm (12 in.) of every outlet box, junction box,
cabinet, or fitting and at intervals not exceeding 1.4m (4 1⁄2 ft.) where
installed on or across framing members.
(C) Supporting. Unless otherwise permitted, Type AC cable shall be
supported at intervals not exceeding 1.4m (4 1⁄2 ft.).
Horizontal runs of Type AC cable installed in wooden or metal
framing members or similar supporting means shall be considered
supported where such support does not exceed 1.4m (4 1⁄2 ft.)
intervals.
330.2 Definition.
Metal Clad Cable, Type MC. A factory assembly of one or more
insulated circuit conductors with or without optical fiber members
enclosed in an armor of interlocking metal tape, or a smooth or
corrugated metallic sheath.
330.17 Through or Parallel to Framing Members.
L.7
StrongHold ™ Codes and Standards
Order number of pieces required, in multiples of Standard Package Quantity.
330.30 Securing and Supporting.
(A) General. Type MC cable shall be supported and secured by
staples, cable ties, straps, hangers, or similar fittings or other
approved means designed and installed so as not to damage
the cable.
(B) Securing. Unless otherwise provided, cables shall be secured
at intervals not exceeding 1.8m (6 ft.). Cables containing four or
fewer conductors sized no larger than 10 AWG shall be secured
within 300mm (12 in.) of every box, cabinet, fitting, or other cable
termination. In vertical installations, listed cables with ungrounded
conductors 250 kcmil and larger shall be permitted to be secured at
intervals not exceeding 3m (10 ft.).
(C) Supporting. Unless otherwise provided, cables shall be
supported at intervals not exceeding 1.8m (6 ft.). Horizontal runs of
Type MC cable installed in wooden or metal framing members or
similar supporting means shall be considered supported and secured
where such support does not exceed 1.8m (6 ft.) intervals.
334.2 Definitions.
Nonmetallic-Sheathed Cable. A factory assembly of two or more
insulated conductors enclosed within an overall nonmetallic jacket.
334.17 Through or Parallel to Framing Members.
Types NM, NMC, or NMS cable shall be protected in accordance
with 300.4 where installed through or parallel to framing members.
Grommets used as required in 300.4 (B)(1) shall remain in place and
be listed for the purpose of cable protection.
334.30 Securing and Supporting.
Nonmetallic-sheathed cable shall be supported and secured by
staples, cable ties, straps, hangers, or similar fittings designed and
installed so as not to damage the cable, at intervals not exceeding
1.4m (4 1⁄2 ft.) and within 300mm (12 in.) of every outlet box,
junction box, cabinet, or fitting. Flat cables shall not be stapled
on edge.
Sections of cable protected from physical damage by raceway
shall not be required to be secured within the raceway.
(A) Horizontal Runs Through Holes and Notches.
In other than vertical runs, cables installed in accordance with
300.4 shall be considered to be supported and secured where
such support does not exceed 1.4m (4 1⁄2 ft.) intervals and the
nonmetallic-sheathed cable is securely fastened in place by an
approved means within 300mm (12 in.) of each box, cabinet, conduit
body, or other nonmetallic-sheathed cable termination.
Informational Note: See 314.17 (C) for support where nonmetallic
boxes are used.
342.30 Securing and Supporting.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.8
Codes and
Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
NFPA 70; National Electric Code; 2014 Revision
(continued)
IMC shall be installed as a complete system in accordance with
300.18 and shall be securely fastened in place and supported in
accordance with 342.30 (A) and (B).
(A) Securely Fastened. IMC shall be secured in accordance
with one of the following:
(1) IMC shall be securely fastened within 900mm (3 ft.) of each
outlet box, junction box, device box, cabinet, conduit body, or
other conduit termination.
(2) Where structural members do not readily permit fastening
within 900mm (3 ft.), fastening shall be permitted to be increased
to a distance of 1.5m (5 ft.).
(3) Where approved, conduit shall not be required to be securely
fastened within 900mm (3 ft.) of the service head for above-theroof termination of a mast.
(B) Supports. IMC shall be supported in accordance with one of
the following:
(1) Conduit shall be supported at intervals not exceeding
3m (10 ft.).
(2) The distance between supports for straight runs of conduit
shall be permitted in accordance with Table 344.30 (B)(2), provided
the conduit is made up with threaded couplings and such
supports prevent transmission of stresses to termination where
conduit is deflected between supports.
place and supported in accordance with 348.30 (A) and (B).
(A) Securely Fastened. FMC shall be securely fastened in place
by an approved means within 300mm (12 in.) of each box, cabinet,
conduit body, or other conduit termination and shall be supported
and secured at intervals not to exceed 1.4m (4 1⁄2 ft.) .
(B) Supports. Horizontal runs of FMC supported by openings
through framing members at intervals not greater than 1.4m (4 1⁄2
ft.) and securely fastened within 300mm (12 in.) of termination points
shall be permitted.
344.30 Securing and Supporting. RMC shall be installed as a
complete system in accordance with 300.18 and shall be securely
fastened in place and supported in accordance with 344.30 (A)
and (B).
(A) Securely Fastened. RRMC shall be secured in accordance with
one of the following:
(1) RMC shall be securely fastened within 900mm (3 ft.) of each
outlet box, junction box, device box, cabinet, conduit body, or
other conduit termination.
(2) Fastening shall be permitted to be increased to a distance
of 1.5m (5 ft.) where structural members do not readily permit
fastening within 900mm (3 ft.).
(3) Where approved, conduit shall not be required to be
securely fastened within 900mm (3 ft.) of the service head for
above-the-roof termination of a mast.
(B) Supports. RMC shall be supported in accordance with one of
the following:
(1) Conduit shall be supported at intervals not exceeding
3m (10 ft.).
(2) The distance between supports for straight runs of conduit
shall be permitted in accordance with Table 344.30 (B)(2),
provided the conduit is made up with threaded couplings and
such supports prevent transmission of stresses to termination
where conduit is deflected between supports.
348.30 Securing and Supporting. FMC shall be securely fastened in
L.9
StrongHold ™ Codes and Standards
Order number of pieces required, in multiples of Standard Package Quantity.
358.30 Securing and Supporting. EMT shall be installed as a
complete system in accordance with 300.18 and shall be
securely fastened in place and supported in accordance
with 358.30 (A) and (B).
(A) Securely Fastened. EMT shall be securely fastened in place at
least every 3m (10 ft.). In addition, each EMT run between termination
points shall be securely fastened within 900mm (3 ft.) of each outlet
box, junction box, device box, cabinet, conduit body, or other tubing
termination.
Exception No. 1: Fastening of unbroken lengths shall be permitted to be
increased to a distance of 1.5m (5 ft.) where structural members do not
readily permit fastening within 900mm (3 ft.).
Exception No. 2: For concealed work in finished buildings or prefinished
wall panels where such securing is impracticable, unbroken lengths
(without coupling) of EMT shall be permitted to
be fished.
(B) Supports. Horizontal runs of EMT supported by openings
through framing members at intervals not greater than 3m (10 ft.)
and securely fastened within 900mm (3 ft.) of termination points shall
be permitted.
362.2 Definition.
Electrical Nonmetallic Tubing (ENT). A nonmetallic, pliable,
corrugated raceway of circular cross section with integral or
associated couplings, connectors, and fittings for the installation of
electrical conductors. ENT is composed of a material that is resistant
to moisture and chemical atmospheres and is flame retardant.
A pliable raceway is a raceway that can be bent by hand with a
reasonable force but without other assistance.
362.30 Securing and Supporting. ENT shall be installed as a
complete system in accordance with 300.18 and shall be securely
fastened in place and supported in accordance with 362.30 (A)
and (B).
(A) Securely Fastened. ENT shall be securely fastened at intervals
not exceeding 900mm (3 ft.). In addition, ENT shall be securely
fastened in place within 900mm (3 ft.) of each outlet box, device box,
junction box, cabinet, or fitting where it terminates.
Exception No. 1: Lengths not exceeding a distance of 1.8m (6 ft.) from
a luminaire terminal connection for tap connections to lighting luminaires
Call 866-405-6654 or visit www.panduit.com/stronghold
L.10
Codes and
Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
shall be permitted without being secured.
Exception No. 2: Lengths not exceeding 1.8m (6 ft.) from the last point
where the raceway is securely fastened for connections within an
accessible ceiling to luminaire(s) or other equipment.
Exception No. 3: For concealed work in finished buildings or prefinished
wall panels where such securing is impracticable,
unbroken lengths (without coupling) of ENT shall be permitted to
be fished.
410.36 Means of Support.
(A) Outlet Boxes. Outlet boxes or fittings installed as required by
314.23 and complying with the provisions of 314.27 (A)(1) and 314.27
(A)(2) shall be permitted to support luminaires.
(B) Suspended Ceilings. Framing members of suspended ceiling
systems used to support luminaires shall be securely fastened to
each other and shall be securely attached to the building structure
at appropriate intervals. Luminaires shall be securely fastened to the
ceiling framing member by mechanical means such as bolts, screws,
or rivets. Listed clips identified for use with the type of ceiling framing
member(s) and luminaire(s) shall also be permitted.
410.154 Fastening. Lighting track shall be securely mounted so
that each fastening is suitable for supporting the maximum weight
of luminaires that can be installed. Unless identified for supports at
greater intervals, a single section 1.2m (4 ft.) or shorter in length shall
have two supports, and, where installed in a continuous row, each
individual section of not more than 1.2m (4 ft.) in length shall have
one additional support.
590.4 General.
(J) Support. Cable assemblies and flexible cords and cables shall be
supported in place at intervals that ensure that they will be protected
from physical damage. Support shall be in the form of staples,
cable ties, straps, or similar type fittings installed so as not to cause
damage. Cable assemblies and flexible cords and cables installed
as branch circuits or feeders shall not be installed on the floor or on
the ground. Extension cords shall not be required to comply with
590.4(J). Vegetation shall not be used for support of overhead
spans of branch circuits or feeders.
Exception: For holiday lighting in accordance with 590.3 (B), where the
conductors or cables are arranged with strain relief devices, tension
take-up devices, or other approved means to avoid damage from the
movement of the live vegetation, trees shall be permitted to be used for
support of overhead spans of branch-circuit
conductors or cables.
StrongHold ™ Codes and Standards
NFPA 70; National Electric Code; 2014 Revision
(continued)
725.24 Mechanical Execution of Work. Class 1, Class 2, and
Class 3 circuits shall be installed in a neat and workmanlike manner.
Cables and conductors installed exposed on the surface of ceilings
and sidewalls shall be supported by the building structure in such a
manner that the cable will not be damaged by normal building use.
Such cables shall be supported by straps, staples, hangers, cable
ties, or similar fittings designed and installed so as not to damage
the cable. The installation shall also comply with 300.4 (D).
760.24 Mechanical Execution of Work.
(A) General. Fire alarm circuits shall be installed in a neat
workmanlike manner. Cables and conductors installed exposed
on the surface of ceilings and sidewalls shall be supported by
the building structure in such a manner that the cable will not be
damaged by normal building use. Such cables shall be supported by
straps, staples, cable ties, hangers, or similar fittings designed and
installed so as not to damage the cable. The installation shall also
comply with 300.4 (D).
800.24 Mechanical Execution of Work.
Communications circuits and equipment shall be installed in a neat
and workmanlike manner. Cables installed exposed on the surface
of ceilings and sidewalls shall be supported by the building structure
in such a manner that the cable will not be damaged by normal
building use. Such cables shall be secured by hardware, including
straps, staples, cable ties, hangers, or similar fittings designed and
installed so as not to damage the cable. The installation shall also
conform to 300.4 (D) and 300.11. Nonmetallic cable ties and other
nonmetallic cable accessories used to secure and support cables in
other spaces used for environmental air (plenums) shall be listed as
having low smoke and heat release properties.
Informational Note No. 1: Accepted industry practices are
described in ANSI/NECA/BICSI 568-2006, Standard for Installing
Commercial Building Telecommunications Cabling;
ANSI/TIA/EIA-568-B.1-2004 — Part 1, General Requirements
Commercial Building Telecommunications Cabling Standard;
ANSI/TIA-569-B-2004, Commercial Building Standard for
Telecommunications Pathways and Spaces; ANSI/TIA-570-B,
Residential Telecommunications Infrastructure, and other
ANSI-approved installation standards.
Informational Note No. 2: See 4.3.11.2.6.5 and 4.3.11.5.5.6 of
NFPA 90A-2012, Standard for the Installation of Air-Conditioning and
Ventilating Systems, for discrete combustible components installed in
accordance with 300.22 (C).
604.7 Installation. Manufactured wiring systems shall be secured
and supported in accordance with the applicable cable or conduit
article for the cable or conduit type employed.
L.11
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.12
Codes and
Standards
Telecommunications Pathways and Spaces;
ANSI/TIA-569-C; Revision May, 2012
6.7.6 Low-Voltage Mounting Bracket
A low-voltage mounting bracket is similar to a plaster ring and may
be used in place of an outlet box where permitted by code.
9.3.2 Telecommunications Pathway Separation From Lighting
Balanced twisted-pair cabling should be separated from fluorescent
lamps and associated fixtures by a minimum of 125mm (5 in.).
9.4.2.1 Planning
The design shall provide a suitable means and method for supporting
cables. Cable shall not be laid directly on the ceiling tile or rails.
9.4.2.2 Clearance
A minimum of 75mm (3 in.) clear vertical space shall be available
above the ceiling tiles for the cabling and pathway.
9.5.4.3 Cable Management
Providing physical management for cabling placed within the access
floor system lessens the chance of damage or reduced performance
over the cable’s life cycle. A method of physical management for
major runs of cabling shall be provided. Management systems such
as raceways, cable tray, and non-continuous cable supports may
be used.
9.7 Non-Continuous Support
Non-continuous supports shall be located at intervals not to
exceed 1.5m (5 ft.). Non-continuous supports shall be selected to
accommodate the immediate and anticipated quantity, weight,
and performance requirements of cables.
Steel, masonry, independent rods, independent support wires or
other structural parts of the building shall be used for cable support
attachment points up to the total weight for which the fastener
is approved. Rods or wires that are currently employed for other
functions (e.g., suspended ceiling grid support) shall not be utilized
as attachment points for non-continuous supports.
NOTE: A weight of 1 kg (2.2 lbs.) (or 0.7 kg/m [0.5 lb./ft.] with spacing
of support wire/rod at 1.5m [5 ft.]) is equivalent to a bundle of sixteen
4-pair 24 AWG UTP cables, including fasteners.
9.8.3.1 Conduit Termination
Conduits shall be reamed to eliminate sharp edges. Metallic conduit
shall be terminated with an insulated bushing.
StrongHold ™ Codes and Standards
BICSI TDMM, 12th Edition; 2009 Revision
Page 5-1: Introduction
Horizontal pathways include:
•
Continuous pathways (e.g., conduit cable tray and
cable matting) used for containment of telecommunications
cabling
•
Non-continuous pathways (e.g., the space between
open-top cable supports [J-hooks]) through which cable is
placed between physical support or containment components
Pages 5-39-5-41: Pathway and Cable Support
Every ceiling distribution system must provide proper support for
cables from the telecommunications space to the work areas served.
Ceiling panels, support channels (T-bars), and suspended ceiling
support wires are not proper cabling supports.
Ceiling conduits, raceways, cable trays, and cabling must be
suspended from or attached to the structural ceiling or walls with
hardware or other installation aids specifically designed to support
their weight.
The pathways must:
•
Have adequate support to withstand cable pulling
•
Be installed with at least 75mm (3 in.) of clear vertical space
above the ceiling tiles and support channels (T-bars) to ensure
accessibility
Horizontal pathways or cable should not rest directly on or be
supported by:
•
Ceiling panels
•
Support channels (T-bars)
•
Ceiling support wires
•
Other components of the suspended ceiling
It is important to provide sufficient space between the suspended
ceiling structure and the telecommunications pathways/cables
to install, maneuver, and store ceiling tiles during service. When
sufficient space is available above the pathway, up to 150mm (6 in.)
should be provided between the suspended ceiling and the cabling
pathways.
Where building codes permit telecommunications cable to be placed
in suspended ceiling spaces without conduit, ceiling zone distribution
pathways may consist of:
•
Cable trays
•
Open-top supports (e.g., J-hooks)
NOTE: J-hooks should be located 1.5m (5 ft.) apart at the maximum
to adequately support and distribute the cable’s weight. The
manufacturer’s specifications for cable loading should be followed.
L.13
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.14
Codes and
Standards
BICSI TDMM, 12th Edition; 2009 Revision (continued)
Cable support devices that have narrow surface areas to support
the cable laying horizontally inside or on top may have a detrimental
effect on the transmissions performance of higher performance
cabling systems.
If possible, a wider surface area should be chosen to support the
cable as a precaution against potential problems. Another precaution
would be to reduce the distance between the support devices.
Suspended cables must be installed with at least 75mm (3 in.) of
clear vertical space above the ceiling tiles and support channels
(T-bars).
For large quantities of cables (50 or more) that converge at the ER,
TR, and other areas, provide cable trays or other special supports
that are specifically designed to support the required cable weight
and volume.
Page 5-57: Telecommunications Outlets/Connectors
Telecommunications outlet/connector boxes must be used in
fire-rated wall installations and must be firestopped appropriately.
Low-voltage mounting brackets (e.g., also known as mud ring,
plaster ring, square-drawn cover, and box eliminator) may be used
where the wall is not fire rated, and are typically used for work
associated with MACs.
Telecommunications outlet/connector boxes installed in dry wall,
plaster, or concrete block wall are available in an array of shapes
and sizes. The size of each telecommunications outlet/connector
box must be of a size that is adequate to accommodate the type
and density of cabling to be installed.
Telecommunications outlet/connector boxes should not be placed
back to back to serve adjacent rooms. This can compromise the
effectiveness of the wall as a sound barrier and as a firestop.
StrongHold ™ Codes and Standards
J-ProTM Cable Support System –
Frequently Asked Questions
Question:
What references define how and where J-hooks are used?
Answer:
J-hooks are a horizontal pathway promoted in the BICSI® TDM
manual as a means to route cable bundles (see catalog pages
O.14 – O.15). Furthermore, the TIA-569-C standard promotes
non-continuous supports as a means to route cable bundles as well
(see catalog page O.13). According to Underwriters Laboratories Inc.
(UL), the portion of the NEC® that defines the requirements of this
cabling pathway is found in Section 300.22 of the NEC (see catalog
pages O.2 – O.4).
Question:
What is the difference between plenum space and air
handling space?
Answer:
The industry-wide confusion regarding the definition of a plenum
space verses an air handling space is very common as the area above
a drop ceiling is mistakenly referred to as a plenum.
Simply stated, the NEC defines a plenum area as, “a compartment
or chamber to which one or more air ducts are connected and
that forms part of the air distribution system.” They also reference,
“the space over a hung ceiling used for environmental air-handling
purposes,” and, “areas beneath raised floors for information
technology equipment,” as air handling space (NEC pg. 70-144 and
70-145; see catalog pages O.2 – O.4). Often, the NEC definition of
these terms differs from their common use in the industry – however,
UL is compatible with the NEC terms and definitions. Therefore,
the space above a hung (or drop/suspended) ceiling utilized as an
air return to the HVAC unit is considered an air handling space.
Additionally, the area below a raised floor used to supply conditioned
air is also considered an air handling space.
Question:
Is the J-ProTM Cable Support System approved by UL for use in
air handling spaces in the United States?
Answer:
Yes, during the development of the J-ProTM Cable Support System,
Panduit coordinated testing and evaluation with UL for approval of
the following statement on all the J-ProTM Cable Support System
products to reduce confusion in the market: “Suitable for use in air
handling spaces in accordance with Section 300.22 (C) and (D) of
the NEC….” This statement is engraved and is visible on the side
or bottom of each part. According to this phrase, the J-ProTM Cable
L.15
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.16
Codes and
Standards
J-ProTM Cable Support System –
Frequently Asked Questions (continued)
Support System can be utilized in the area above the suspended
ceiling (300.22 [C]) or below a raised floor (300.22 [D]), but it cannot
be utilized within ductwork (300.22 [A] and [B]) (see catalog pages
O.2 – O.4). Approval to use J-ProTM Cable Support System above
the suspended ceiling and below the raised floor was a result of
completing/passing testing of the J-ProTM Cable Support System
per the UL standard UL2043, Fire Test for Visible Heat and Smoke
Release for Discrete Products and their Accessories Installed in
Air-Handling Spaces. This test requires product to meet certain
criteria for heat release and smoke density and the values measured
correlate back to the maximum flame spread and smoke index of the
mechanical code. The basic standard used to investigate products
in this category is ANSI/UL 1565, “Positioning Devices”. The J-ProTM
Cable Support System product line is UL listed within UL file
number E136577.
Question:
Is the J-ProTM Cable Support System approved by Underwriters’
Laboratories of Canada (ULC) for use in air handling spaces?
Answer:
Yes, for applications within Canada, the J-ProTM Cable Support
System was tested and evaluated by ULC for approval of the
following statement, “In accordance with CAN/ULC S102.2 in single
units or pairs. 4-foot minimum spacing, FSR = 0, SDC = 35.” This
statement is engraved and visible on the side or bottom of each
part. According to this phrase, the J-ProTM Cable Support System
is approved for the same air handling spaces as defined by the
NEC Article 300.22 (C) and (D) (above the suspended ceiling or
below a raised floor) and meets the S102.2 (Standard Method of
Test for Surface Burning Characteristics of Floor Coverings, and
Miscellaneous Material and Assemblies) requirements as stated in
the National Building Code of Canada. The J-ProTM Cable Support
System product line is ULC listed within ULC file number R21673.
StrongHold ™ Codes and Standards
UL
File E136577
Volume 2, Section 2
Page 1
ULC
File R21673
Volume 1
Description
Product Covered:
USL, CNL – Positioning Devices – Model JP2, JP4, JP75, JP131
General Description:
USL, CNL – Indicates that the products have been evaluated in
accordance with the requirements in UL 1565 and CAN/CSA C22.2
No. 18.5-02 Standards for Positioning Devices.
These devices are a J-ProTM J-hook, and are used in applications
where zone conduit, cable trays, or ladder racks are not available or
applicable.
The J-ProTM J-hook contains a family of parts. This system has
several other brackets and/or components, manufactured from a
high-carbon plated steel, riveted to the JP2, JP4, JP75, and JP131
for a variety of applications.
Table 1
Family of Part Numbers
J-ProTM Cable Support
System Description
JP2
J-ProTM J-hook
Ratings:
These devices are rated 60°C, for indoor use, suitable for use in air
handling spaces in accordance with Sec. 300.22 (C) and (D) of the
National Electrical Code in single units or pairs, and 30 lb. maximum
load rating.
Table 3
Family of Part Numbers
J-ProTM Cable Support
System Description
JP4
J-ProTM J-hook
Ratings:
These devices are rated 60°C, for indoor use, suitable for use in air
handling spaces in accordance with Sec. 300.22 (C) and (D) of the
National Electrical Code, and 100 lb. maximum load rating in single
unit configuration only.
L.17
Order number of pieces required, in multiples of Standard Package Quantity.
Call 866-405-6654 or visit www.panduit.com/stronghold
L.18
Codes and
Standards
Part Number Index
B
Table 4
Family of Part Numbers
J-ProTM Cable Support
System Description
JP75
J-ProTM J-hook
Ratings:
These devices are rated 60°C, for indoor use, suitable for use in air
handling spaces in accordance with Sec. 300.22 (C) and (D) of the
National Electrical Code in single units or pairs, and 15 lb. maximum
load rating.
Table 5
Family of Part Numbers
J-ProTM Cable Support
System Description
JP131
J-ProTM J-hook
Ratings:
These devices are rated 60°C, for indoor use, suitable for use in air
handling spaces in accordance with Sec. 300.22 (C) and (D) of the
National Electrical Code in single units or pairs, and 20 lb. maximum
load rating.
Scope for UL 1565 Positioning Devices
1 Scope
1:1 This standard applies to those metallic and nonmetallic
devices used for positioning – which may include bundling and
securing – or to a limited extent supporting cable, wire, conduit, or
tubing of a wiring system in electrical installations, to reduce the
risk of fire, electric shock, or injury to persons. This standard applies
to, but is not limited to, cable ties, cable tie mounting blocks, cable
clamps, cable and conduit clips, and non-raceway ducts.
L.19
Order number of pieces required, in multiples of Standard Package Quantity.
BR-1.5-PAF............................H.64
BR-1.5-SN..............................H.64
BR-1.5-TW.............................H.64
BR-1.25-1/4-20......................H.64
BR-1.25-10-24.......................H.64
BR-1.25-14WS.......................H.64
BR-2.0-1/4-20........................H.64
BR-2.0-10-24.........................H.64
BR-2.0-14W...........................H.64
BR-2.0-PAF............................H.64
BR-2.0-SN..............................H.64
BR-2.0-TW.............................H.64
BR-4.0-1/4-20........................H.64
BR-.50-10-24.........................H.64
BR-.75-10-24.........................H.64
C
CSM-1.25-C...........................H.48
D
DS1........................................... I.3
DS5........................................... I.3
E
E10-6FB-Q............................... E.3
E10-6LFB-Q............................. E.4
E10-6RB-Q............................... E.3
E10-8FB-Q............................... E.3
E10-8LFB-Q............................. E.4
E10-8RB-Q............................... E.3
E10-10FB-Q............................. E.3
E10-10LFB-Q........................... E.4
E10-10RB-Q............................. E.3
E10-14FB-Q............................. E.3
E10-14LFB-Q........................... E.4
E10-14RB-Q............................. E.3
E14-4RB-Q*.............................. E.3
E14-6FB-Q*.............................. E.3
E14-6LFB-Q*............................ E.4
E14-6RB-Q*.............................. E.3
E14-8FB-Q*.............................. E.3
E14-8LFB-Q*............................ E.4
E14-8RB-Q*.............................. E.3
E14-10FB-Q*............................ E.3
E14-10LFB-Q*.......................... E.4
E14-10RB-Q*............................ E.3
E18-4RB-Q*.............................. E.3
E18-6FB-Q*.............................. E.3
E18-6LFB-Q*............................ E.4
E18-6RB-Q*.............................. E.3
E18-8FB-Q*.............................. E.3
E18-8LFB-Q*............................ E.4
E18-8RB-Q*.............................. E.3
E18-10FB-Q*............................ E.3
E18-10LFB-Q*.......................... E.4
E18-10RB-Q*............................ E.3
EBNF14-4FIB-Q........................ E.6
EBNF14-4FIM-Q....................... E.6
EBNF18-4FIB-Q........................ E.6
EBNF18-4FIM-Q....................... E.6
EBV14-4B-Q............................. E.6
EBV14-4MB-Q.......................... E.6
EBV18-4B-Q............................. E.6
EBV18-4MB-Q.......................... E.6
ED10-250M-Q.......................... E.5
ED14-188-Q*............................ E.5
ED14-250MB-Q*...................... E.5
ED14-250-Q*............................ E.5
ED18-188-Q*............................ E.5
ED18-250MB-Q*...................... E.5
ED18-250-Q*............................ E.5
EDNF10-250FI-Q...................... E.4
EDNF14-187MB-Q.................... E.5
EDNF14-188FIB-Q*................... E.4
EDNF14-250FIB-Q*................... E.4
EDNF18-187MB-Q.................... E.5
EDNF18-188FIB-Q*................... E.4
EDNF18-250FIB-Q*................... E.4
EDNF10250FIMB-Q................... E.5
EDNF14250FIMB-Q*................. E.5
EDNF18250FIMB-Q*................. E.5
EDV10-11MB-Q........................ E.8
EDV10-250FIB-Q...................... E.5
EDV10-250M-Q........................ E.5
EDV10-250P-Q......................... E.6
EDV10-250-Q........................... E.5
EDV14-87MB-Q........................ E.8
EDV14-187MB-Q...................... E.5
EDV14-188B-Q*....................... E.5
EDV14-250B-Q*....................... E.5
EDV14-250FIB-Q...................... E.5
EDV14-250M-Q*....................... E.5
EDV14-250P-Q*........................ E.6
EDV18-87MB-Q........................ E.8
EDV18-187MB-Q...................... E.5
EDV18-188B-Q*....................... E.5
EDV18-250B-Q*....................... E.5
EDV18-250FIB-Q...................... E.5
EDV18-250M-Q*....................... E.5
EDV18-250P-Q*........................ E.6
EJN218-216-Q*........................ E.8
EJN314-412-Q......................... E.8
EJN418-212-Q......................... E.8
EQSP10-18D-Q......................... E.7
EQSP10-Q................................ E.7
EQSP14D-Q*............................. E.7
EQSP14-Q................................ E.7
EQSP18D-Q.............................. E.7
EQSP18-Q................................ E.7
ES10B-Q................................... E.6
ES14B-Q*................................. E.6
ES18B-Q*................................. E.6
ESV6-ESV8-Q........................... E.7
ESV8-ESV10-Q......................... E.7
ESV8-ESV14-Q......................... E.7
ESV10BX-Q............................... E.6
ESV10-ESV14-Q....................... E.7
ESV10-ESV18-Q....................... E.7
ESV14BX-Q*............................. E.6
ESV14-ESV18-Q....................... E.7
ESV18BX-Q*............................. E.6
EV6-10R-Q............................... E.2
EV6-12R-Q............................... E.2
EV6-38R-Q............................... E.2
EV6-56R-Q............................... E.2
EV8-8R-Q................................. E.2
EV8-12R-Q............................... E.2
EV8-14R-Q............................... E.2
EV8-38R-Q............................... E.2
EV8-56R-Q............................... E.2
EV10-6FB-Q............................. E.3
EV10-6LFB-Q............................ E.4
EV10-6RB-Q............................. E.2
EV10-8FB-Q............................. E.3
EV10-8FNB-Q........................... E.4
EV10-8LFB-Q............................ E.4
Call 866-405-6654 or visit www.panduit.com/stronghold
M.1
Part Number Index
EV10-8RB-Q............................. E.2
EV10-10FB-Q........................... E.3
EV10-10FNB-Q......................... E.4
EV10-10LFB-Q.......................... E.4
EV10-10RB-Q........................... E.2
EV10-12RB-Q........................... E.2
EV10-14FB-Q........................... E.3
EV10-14LFB-Q.......................... E.4
EV10-14RB-Q........................... E.2
EV10-38RB-Q........................... E.2
EV10-56FB-Q........................... E.3
EV10-56RB-Q........................... E.2
EV10-P55-Q............................. E.7
EV14-6FB-Q*............................ E.3
EV14-6FNB-Q........................... E.4
EV14-6LFB-Q*.......................... E.4
EV14-6RB-Q*............................ E.2
EV14-8FB-Q*............................ E.3
EV14-8FNB-Q........................... E.4
EV14-8LFB-Q*.......................... E.4
EV14-8RB-Q*............................ E.2
EV14-10FB-Q*.......................... E.3
EV14-10FNB-Q......................... E.4
EV14-10LFB-Q*........................ E.4
EV14-10RB-Q*.......................... E.2
EV14-14FB-Q........................... E.3
EV14-14RB-Q*.......................... E.2
EV14-38RB-Q........................... E.2
EV14-56RB-Q*.......................... E.2
EV14-P47B-Q*.......................... E.7
EV18-6FB-Q*............................ E.3
EV18-6LFB-Q*.......................... E.4
EV18-6RB-Q*............................ E.2
EV18-8FB-Q*............................ E.3
EV18-8LFB-Q*.......................... E.4
EV18-8RB-Q*............................ E.2
EV18-10FB-Q*.......................... E.3
EV18-10LFB-Q*........................ E.4
EV18-10RB-Q*.......................... E.2
EV18-14FB-Q........................... E.3
EV18-14RB-Q*.......................... E.2
EV18-56RB-Q*.......................... E.2
EV18-P47B-Q*.......................... E.7
G
GSC10-32-38-C........................F.2
GSH10-32-38-C........................F.2
H
HLSP1.5S-X0..........................H.61
HLSP1.5S-X12........................H.61
HLSP3S-X0.............................H.61
HLSP3S-X12...........................H.61
HLSP5S-X0.............................H.61
HLSP5S-X12...........................H.61
HLTP2I-X0...............................H.61
HLTP2I-X12.............................H.61
HLTP3I-X0...............................H.61
HLTP3I-X12.............................H.61
HLTT1.5S-Q20........................H.62
HT2-BLU...................................D.4
HT2-GRN..................................D.4
HT2-ORN..................................D.4
HT2-RED..................................D.4
HT2S-BLK-YEL..........................D.4
HT2S-RED-WHT........................D.4
HT2-WHT..................................D.4
HT2-YEL...................................D.4
M.2
HT3S-BLK-YEL..........................D.4
HT3S-RED-WHT........................D.4
HTB3-C-M................................D.3
HTB3-DNE-M............................D.3
HTB3-HV-M..............................D.3
HTDU3B-W...............................D.3
HTDU3G-S................................D.3
HTDU3O-T................................D.3
HTDU3R-E................................D.3
HTDU30-FO..............................D.3
HTDU60-FO..............................D.3
HTU3G-T-M..............................D.2
HTU3O-FO-M............................D.2
HTU3O-T-M..............................D.2
HTU3R-E-M..............................D.2
HTU3Y-EF.................................D.2
HTU3Y-E-M...............................D.2
HTU6O-FO................................D.2
HTU6R-E...................................D.2
HTU6Y-E...................................D.2
HTU6Y-G...................................D.2
HTU60-T...................................D.2
HTU60-TV.................................D.2
I
IMLT25S-C................................B.4
IMLT25S-C6L............................B.4
IMLT51H-L................................B.4
IMLT51H-L6L............................B.4
IMLT51S-C................................B.4
IMLT51S-C6L............................B.4
IMLT69H-L................................B.4
IMLT69H-L6L............................B.4
IMLT69S-C................................B.4
IMLT69S-C6L............................B.4
IMLT102H-L..............................B.4
IMLT102H-L6L..........................B.4
IMLT102S-C..............................B.4
IMLT102S-C6L..........................B.4
IMLT152H-L..............................B.4
IMLT152H-L6L..........................B.4
IMLT152S-C..............................B.4
IMLT152S-C6L..........................B.4
IMLT203H-L..............................B.4
IMLT203H-L6L..........................B.4
IMLT203S-C..............................B.4
IMLT203S-C6L..........................B.4
IMLT254H-L..............................B.4
IMLT254H-L6L..........................B.4
IMLT254S-C..............................B.4
IMLT254S-C6L..........................B.4
IMLT304H-Q.............................B.4
IMLT304H-Q6L.........................B.4
IMLT304S-Q.............................B.4
IMLT304S-Q6L..........................B.4
IMLT355H-Q.............................B.4
IMLT355H-Q6L.........................B.4
IMLT355S-Q.............................B.4
IMLT355S-Q6L..........................B.4
IMLT380S-Q.............................B.4
IMLT380S-Q6L..........................B.4
IMLTFC38H-C6L........................B.6
IMLTFC38S-C6L........................B.6
IMLTFC51H-L6L........................B.6
IMLTFC51S-C6L........................B.6
IMLTFC64H-C6L........................B.6
IMLTFC64S-C6L........................B.6
IMLTFC69H-L6L........................B.6
IMLTFC86H-C6L........................B.6
Order number of pieces required, in multiples of Standard Package Quantity.
StrongHold ™ Part Number Index
IMLTFC86S-C6L........................B.6
IMLTFC102H-L6L......................B.6
IMLTFC102S-C6L......................B.6
IMLTFC137H-C6L......................B.6
IMLTFC137S-C6L......................B.6
IMLTFC152H-L6L......................B.6
IMLTFC152S-C6L......................B.6
IMLTFC203H-L6L......................B.6
IMLTFC203S-C6L......................B.6
IMS9.5T35-QR6L......................B.8
IMS12T35-QR6L.......................B.8
IMS16T35-QR6L.......................B.8
IMS19T75-QR6L.......................B.8
IMSBE19-C6L...........................B.8
IMSBL9.5-C6L..........................B.8
IMSBL12-C6L...........................B.8
IMSBL16-C6L...........................B.8
IMSP9.5T35-QR6L....................B.8
IMSP12T35-QR6L.....................B.8
IMSP16T35-QR6L.....................B.8
J
JMCB-X..................................H.60
JMCMB25-1-X........................H.60
JMCMB25-3-X........................H.60
JMDWB-1-X...........................H.60
JMDWB-3-X...........................H.60
JMJH2W-X20.........................H.60
JMJH2-X20............................H.60
JMSBCB87-1-X......................H.60
JMSBCB87-3-X......................H.60
JMTRB38-1-X.........................H.60
JMTRB38-3-X.........................H.60
JP2CMB-L20..........................H.53
JP2CP-L20.............................H.53
JP2DW-L20............................H.53
JP2HBC25RB-L20...................H.53
JP2HBC50RB-L20...................H.53
JP2HBC75RB-L20...................H.53
JP2SBC50-L20.......................H.53
JP2SBC50RB-L20...................H.53
JP2SBC87-L20.......................H.53
JP2SBC87RB-L20...................H.53
JP2UF100-L20.......................H.53
JP2W-L20..............................H.53
JP2WP2B-L20........................H.53
JP2ZP-L20.............................H.53
JP4CMB-X20..........................H.54
JP4CP-X20.............................H.54
JP4HBC25RB-X20..................H.54
JP4HBC50RB-X20..................H.54
JP4HBC75RB-X20..................H.54
JP4SBC50RB-X20...................H.54
JP4SBC50-X20.......................H.54
JP4SBC87RB-X20...................H.54
JP4SBC87-X20.......................H.54
JP4UF100-X20.......................H.54
JP4WP2B-X20........................H.54
JP4W-X20..............................H.54
JP4ZP-X20.............................H.54
JP75CMB-L20........................H.51
JP75CP-L20...........................H.51
JP75DW-L20..........................H.51
JP75HBC25RB-L20.................H.51
JP75HBC50RB-L20.................H.51
JP75HBC75RB-L20.................H.51
JP75SBC50-L20.....................H.51
JP75SBC50RB-L20.................H.51
JP75SBC87-L20.....................H.51
JP75SBC87RB-L20.................H.51
JP75UF100-L20.....................H.51
JP75W-L20............................H.51
JP75WP2B-L20......................H.51
JP75ZP-L20...........................H.51
JP131CMB-L20......................H.52
JP131CP-L20.........................H.52
JP131DW-L20........................H.52
JP131HBC25RBL20................H.52
JP131HBC50RBL20................H.52
JP131HBC75RBL20................H.52
JP131SBC50-L20...................H.52
JP131SBC50RBL20................H.52
JP131SBC87-L20...................H.52
JP131SBC87RBL20................H.52
JP131UF100-L20...................H.52
JP131W-L20..........................H.52
JP131WP2B-L20....................H.52
JP131ZP-L20.........................H.52
K
KWP3Y................................... J.13
KWPY..................................... J.13
L
LV-S-1G..................................H.66
LV-S-2G..................................H.66
LV-W-1G.................................H.66
LV-W-2G.................................H.66
M
MC/AC....................................H.44
MSG-1.3-C....................H.47, H.49
MSGV-1.3-C...........................H.47
MSPT-1.3...............................H.49
N
NK^HSFIWY.............................. J.9
NK2HSRFIW............................ J.10
NK2RMFIW.....................J.12, J.14
NK4HSRFIW............................ J.10
NK4MFIW.......................J.12, J.14
NK4RMFIW.....................J.12, J.14
NK4VSF.................................... J.9
NK4VSRFIW............................ J.10
NK5EPC^*Y.............................. J.4
NK5EPPG12WY......................... J.6
NK5EPPG24Y............................ J.6
NK5EPPG48Y............................ J.6
NK6PC^*Y................................ J.4
NK6PPG12WY........................... J.6
NK6PPG24Y.............................. J.6
NK6PPG48Y.............................. J.6
NK6X88MIW.......................J.2, J.4
NK6X88MIW-Q.......................... J.2
NK6XPPG24Y............................ J.5
NK6XPPG48Y......................J.5, J.7
NK688MIW............................... J.3
NK688MIW-Q............................ J.3
NK2106MFIW.................J.12, J.14
NK4106MFIW.................J.12, J.14
NKA5EPPG24Y.......................... J.6
NKA5EPPG48Y.......................... J.6
NKA6PPG24Y............................ J.6
NKA6PPG48Y............................ J.6
NKA6XPPG24Y.......................... J.5
Call 866-405-6654 or visit www.panduit.com/stronghold
M.3
Part Number Index
NKA6XPPG48Y.......................... J.5
NKBMIW-X.............................. J.15
NKBNCMIWY........................... J.15
NKF^^S................................... J.9
NKFIW.................................... J.15
NK**FIWY.................................. J.9
NK*FNIW................................... J.9
NKFP12W................................. J.7
NKFP24Y.................................. J.7
NKFP48Y.................................. J.7
NKHDMIIW.............................. J.15
NKP5E88MIW........................... J.3
NKP5E88MIW-Q........................ J.3
NKPP24FMY............................. J.7
NKPP48FMY............................. J.7
NKPPA24FMY........................... J.7
NKPPA48FMY........................... J.7
NKSPB.................................... J.16
NKUSBAAIW............................ J.15
Non-metallic...........................H.44
P
P4ACS....................................H.71
P4G16....................................H.74
P4G162..................................H.75
P4H24....................................H.21
P4H58....................................H.21
P4H912..................................H.21
P4TI........................................H.78
P4TI24....................................H.26
P4TI912..................................H.26
P4TIB......................................H.32
P4TIO.....................................H.32
P4WN.....................................H.80
P4Z34*...................................H.10
P4Z348P.................................H.10
P4Z3412P...............................H.10
P4Z3416M..............................H.10
P4Z3416P...............................H.10
P4Z34812M............................H.10
P6A........................................H.79
P6A24....................................H.26
P6A58....................................H.26
P6A912..................................H.26
P6AO......................................H.32
P6M..........................................H.1
P6M24......................................H.3
P6M24SM.................................H.4
P6M58......................................H.3
P6M58SM.................................H.4
P6M912....................................H.3
P6M912SM...............................H.4
P6MATA..................................H.69
P6MATS..................................H.70
P6MB18.................................H.14
P6MB18A...............................H.14
P6MF......................................H.38
P6TA24...................................H.26
P6TA58...................................H.26
P6TB......................................H.32
P6TI........................................H.78
P6TIB......................................H.32
P6TIO.....................................H.32
P6TO......................................H.32
P6Z34.....................................H.10
P8P..........................................H.2
P8P8P....................................H.11
P8P12P..................................H.11
P8P16P..................................H.11
M.4
P8P24......................................H.7
P8P24SM.................................H.7
P8P58......................................H.7
P8P58SM.................................H.7
P8P912....................................H.7
P8P912SM...............................H.7
P8PATA...................................H.69
P8PATS...................................H.70
P8PF.......................................H.38
P12P........................................H.2
P12P12P................................H.11
P12P16P................................H.11
P12P24....................................H.7
P12P24SM...............................H.7
P12P58....................................H.7
P12P58SM...............................H.7
P12P912..................................H.7
P12P912SM.............................H.7
P12PATA.................................H.69
P12PATS.................................H.70
P12PF.....................................H.38
P16M........................................H.1
P16M24....................................H.3
P16M24SM...............................H.4
P16M58....................................H.3
P16M58SM...............................H.4
P16M912..................................H.3
P16M912SM.............................H.4
P16MATA................................H.69
P16MATS................................H.70
P16MB18...............................H.15
P16MB18A.............................H.15
P16MF....................................H.38
P16P........................................H.2
P16P16P................................H.11
P16P24....................................H.7
P16P24SM...............................H.7
P16P58....................................H.7
P16P58SM...............................H.7
P16P912..................................H.7
P16P912SM.............................H.7
P16PATA.................................H.69
P16PATS.................................H.70
P16PF.....................................H.38
P20M........................................H.1
P20M24....................................H.3
P20M24SM...............................H.4
P20M58....................................H.3
P20M58SM...............................H.4
P20M912..................................H.3
P20M912SM.............................H.4
P24M........................................H.1
P24M24....................................H.3
P24M24SM...............................H.4
P24M58....................................H.3
P24M58SM...............................H.4
P24M912..................................H.3
P24M912SM.............................H.4
P32M........................................H.1
P32M24....................................H.3
P32M24SM...............................H.4
P32M58....................................H.3
P32M58SM...............................H.4
P32M912..................................H.3
P32M912SM.............................H.4
P122......................................H.28
P123......................................H.28
P166M....................................H.11
P304B2..................................H.35
P350......................................H.39
Order number of pieces required, in multiples of Standard Package Quantity.
StrongHold ™ Part Number Index
P449......................................H.17
P512......................................H.72
P512A....................................H.72
P512HDK................................H.73
P512HDT................................H.73
P515A....................................H.68
P520......................................H.74
P766......................................H.40
P766PMD...............................H.40
P812M......................................H.1
P812M4I**................................H.1
P812M24..................................H.3
P812M24SM.............................H.4
P812M58..................................H.3
P812M58SM.............................H.4
P812M912................................H.3
P812M912SM...........................H.4
P812MATA..............................H.69
P812MATS..............................H.70
P812MB18.............................H.14
P812MB18A...........................H.14
P812MB18S...........................H.15
P812MB1824.........................H.14
P812MF..................................H.38
P1224TI..................................H.31
P1226T...................................H.31
P1226TI..................................H.31
P1236M..................................H.30
P1238P..................................H.30
P1616M..................................H.11
P1620M..................................H.11
P1624M..................................H.11
P3508P..................................H.39
P12312P................................H.30
P12316M................................H.30
P12316P................................H.30
P12320M................................H.30
P16812M................................H.11
P35012P................................H.39
P35016M................................H.39
P35016P................................H.39
P123812M..............................H.30
P350812M..............................H.39
PAF14.....................................H.27
PAO........................................H.81
PAOL8P..................................H.19
PAOL12P................................H.19
PAOL16P................................H.19
PATA4I....................................H.68
PBC........................................H.20
PBC*.......................................H.20
PBC8P....................................H.24
PBC8PSM...............................H.24
PBC12P..................................H.24
PBC12PSM.............................H.24
PBC16M.................................H.24
PBC16MSM............................H.24
PBC16P..................................H.24
PBC16PSM.............................H.24
PBC20M.................................H.24
PBC20MSM............................H.24
PBC24M.................................H.24
PBC24MSM............................H.24
PBC32M.................................H.24
PBC32MSM............................H.24
PBC200..................................H.20
PBC200CD1B..........................H.25
PBC200CD2.5B.......................H.25
PBC200CD2B..........................H.25
PBC200CD3B..........................H.25
PBC200CD4B..........................H.25
PBC200CD5B..........................H.25
PBC400..................................H.20
PBC812M...............................H.24
PBC812MSM..........................H.24
PCATHBA................................H.55
PCD0B......................................H.2
PCD1B......................................H.2
PCD2.5B...................................H.2
PCD2B......................................H.2
PCD3B......................................H.2
PCD4B......................................H.2
PCD5B......................................H.2
PCD6B......................................H.2
PCD7B......................................H.2
PCD8B......................................H.2
PCD9B......................................H.2
PCJ6.......................................H.44
PCMB-1....................................G.2
PCMB-2....................................G.2
PCMB-3....................................G.2
PCMB-4....................................G.2
PCMB-5....................................G.2
PCMB-6....................................G.2
PCMB-7....................................G.2
PCMB-8....................................G.2
PCMB-9....................................G.2
PCMB-11..................................G.2
PCMB-12..................................G.2
PCMB-13..................................G.2
PCMB-14..................................G.2
PCMB-15..................................G.2
PCMB-16..................................G.2
PCMB-25..................................G.2
PCNB8P..................................H.19
PCNB12P................................H.19
PCNB812M.............................H.19
PCS16....................................H.35
PCS812D................................H.35
PDS12A..................................H.67
PEC311..................................H.76
PEC3114Z34..........................H.76
PFB6M....................................H.46
PFB8P....................................H.46
PFB12P..................................H.46
PFB812M................................H.46
PFBS18....................................H.6
PFMBS18...............................H.43
PFXC20..................................H.45
PH4........................................H.34
PH6........................................H.34
PH23......................................H.34
PIDS.......................................H.71
PJ1A4.....................................H.40
PJ1A6.....................................H.40
PJ1A25...................................H.40
PJ1A35...................................H.40
PK8..........................................H.9
PK12........................................H.9
PK16*.......................................H.9
PK20*.......................................H.9
PKX*.........................................H.8
PM24......................................H.22
PM24S...................................H.22
PM58......................................H.22
PM58S...................................H.22
PM912....................................H.22
PM912S.................................H.22
PMCS50.................................H.18
PMCS100...............................H.18
Call 866-405-6654 or visit www.panduit.com/stronghold
M.5
Part Number Index
PMCS101...............................H.18
PMEB1...................................H.34
PMF250..................................H.37
PMF375..................................H.37
PMF500..................................H.37
PMF625..................................H.37
PMF750..................................H.37
PMFO.....................................H.36
PMFS......................................H.36
PMSF......................................H.36
PMSR24.................................H.33
PMSR58.................................H.33
PMSR912...............................H.33
PMSS24.................................H.33
PMSS58.................................H.33
PMSS912...............................H.33
PPT16.....................................H.75
PRBS16..................................H.42
PRBS24..................................H.42
PRLC......................................H.67
PSC2A....................................H.16
PSC2B....................................H.16
PSC2C....................................H.16
PSC2D....................................H.16
PSC2E....................................H.16
PSC2F....................................H.16
PSC2G....................................H.16
PSC4A....................................H.16
PSC4B....................................H.16
PSC4C....................................H.16
PSC4D....................................H.16
PSC4E....................................H.16
PSC4F....................................H.16
PSC4G....................................H.16
PSC8A....................................H.16
PSC8B....................................H.16
PSC8C....................................H.16
PSC8D....................................H.16
PSC8E....................................H.16
PSC8F....................................H.16
PSC8G....................................H.16
PSCB-3Y...................................G.3
PSCB-3YELY*............................G.3
PSCB-5Y...................................G.3
PSCB-6Y...................................G.3
PSCB-12Y.................................G.3
PSCB-13Y.................................G.3
PSCB-16Y.................................G.3
PSCH6B..................................H.12
PSCH8B..................................H.12
PSCH12B................................H.12
PSCH16B................................H.12
PSCH20B................................H.12
PSCH24B................................H.12
PSCH32B................................H.12
PSCH40B................................H.12
PSCH48B................................H.12
PSCH56B................................H.12
PSCH64B................................H.12
PSCH72B................................H.12
PSGB16A..................................H.5
PSGB24A..................................H.5
PSK85I...................................H.13
PSK125I.................................H.13
PSK165I.................................H.13
PSK205..................................H.13
PSK245I.................................H.13
PSK325I.................................H.13
PSK405I.................................H.13
PSK485I.................................H.13
M.6
PSK565I.................................H.13
PSK645I.................................H.13
PTSGB16................................H.41
PTSGB24................................H.41
PVF14.....................................H.27
PVF144TI................................H.29
PVF146T.................................H.29
PVF146TI................................H.29
PWMX3...................................H.17
PWMX6...................................H.17
S
S4-18-C................................... A.4
S4-18-C0................................. A.4
S4-18-M................................... A.4
S4-18-M0................................. A.4
S5-50-C................................... A.6
S5-50-C0................................. A.6
S5-50-M................................... A.6
S5-50-M0................................. A.6
S6-18-C................................... A.4
S6-18-C0................................. A.4
S6-18-M................................... A.4
S6-18-M0................................. A.4
S6-40-C................................... A.4
S6-40-C0................................. A.4
S6-40-M................................... A.4
S6-40-M0................................. A.4
S6-50-C................................... A.6
S6-50-C0................................. A.6
S6-50-M................................... A.6
S6-50-M0................................. A.6
S7-50-C................................... A.6
S7-50-C0................................. A.6
S7-50-C2................................. A.6
S7-50-M................................... A.6
S7-50-M0................................. A.6
S8-18-C................................... A.4
S8-18-C0................................. A.4
S8-18-M................................... A.4
S8-18-M0................................. A.4
S8-40-C................................... A.4
S8-40-C0................................. A.4
S8-40-M................................... A.4
S8-40-M0................................. A.4
S8-50-C................................... A.6
S8-50-C0................................. A.6
S8-50-M................................... A.6
S8-50-M0................................. A.6
S10-50-C................................. A.6
S10-50-C0............................... A.6
S12-40-C................................. A.4
S12-40-C0............................... A.4
S12-40-M................................. A.4
S12-40-M0............................... A.4
S12-50-C................................. A.6
S12-50-C0............................... A.6
S12-50-C2............................... A.6
S12-50-M................................. A.6
S12-50-M0............................... A.6
S14-120-L.............................. A.10
S14-120-L0............................ A.10
S14-120-TL............................ A.10
S14-120-TL0.......................... A.10
S15-40-C................................. A.4
S15-40-C0............................... A.4
S15-50-C................................. A.6
S15-50-C0............................... A.8
S15-50-C2............................... A.8
Order number of pieces required, in multiples of Standard Package Quantity.
StrongHold ™ Part Number Index
S15-50-M................................. A.8
S15-50-M0............................... A.8
S17-50-C................................. A.8
S17-50-C0............................... A.8
S17-50-M................................. A.8
S17-50-M0............................... A.8
S18-120-L.............................. A.10
S18-120-L0............................ A.10
S18-175-L.............................. A.12
S18-175-L0............................ A.12
S21-50-C................................. A.8
S21-50-C0............................... A.8
S21-50-M................................. A.8
S21-50-M0............................... A.8
S21-120-C............................. A.10
S21-120-C0........................... A.10
S21-120-L.............................. A.10
S21-120-L0............................ A.10
S21-175-C............................. A.12
S21-175-C0........................... A.12
S21-175-L.............................. A.12
S21-175-L0............................ A.12
S24-120-L.............................. A.10
S24-120-L0............................ A.10
S24-120-Q............................. A.10
S24-120-Q0........................... A.10
S24-175-L.............................. A.12
S24-175-L0............................ A.12
S30-120-L.............................. A.10
S30-120-L0............................ A.10
S30-120-X............................. A.10
S30-120-X0........................... A.10
S31-175-L.............................. A.12
S31-175-L0............................ A.12
S32-175-L.............................. A.12
S32-175-L0............................ A.12
S36-175-L.............................. A.12
S36-175-L0............................ A.12
S40-175-L.............................. A.12
S40-175-L0............................ A.12
S40-175-X............................. A.12
S40-175-X0........................... A.12
S48-175-L.............................. A.12
S48-175-L0............................ A.12
S48-175-L8............................ A.12
SC8-50-S10-C........................ A.14
SC8-50-S10-C0...................... A.14
SC15-120-S25-L.................... A.14
SC15-120-S25-L0.................. A.14
SGPL12-7S-L............................F.2
SGPL12-8S-L............................F.2
SGPL12-10S-L..........................F.2
SGPL12-12S-L..........................F.2
SGPL14-8S-L............................F.2
SGPS12-8FT-L...........................F.2
SGPS12-8FT-L10.......................F.2
SGPS12-8FT-L20.......................F.2
SGPS12-8SRF-L........................F.2
SGPS12-8SRT-L........................F.2
SGPSL12-8SFT-Q......................F.2
SGPSS12-8SFF-Q......................F.2
SGPSS12-8SFT-Q......................F.2
SGPSSL12-8S-Q........................F.2
SGPSSS12-8S-Q........................F.2
SMP12A-3X............................ A.18
SMP12A-3X0.......................... A.18
SMP12A-C.............................. A.18
SMP12A-C0............................ A.18
SMP12A-M............................. A.18
SMP12A-M0........................... A.18
SMP16A-3X............................ A.18
SMP16A-3X0.......................... A.18
SMP16A-C.............................. A.18
SMP16A-C0............................ A.18
SMP16A-M............................. A.18
SMP16A-M0........................... A.18
SMP18A-3X............................ A.18
SMP18A-3X0.......................... A.18
SMP18A-C.............................. A.18
SMP18A-C0............................ A.18
SMP18A-M............................. A.18
SMP18A-M0........................... A.18
SR8-50-C............................... A.14
SR8-50-C0............................. A.14
SRB19BLY................................. J.8
SRBM19BLY.............................. J.8
SRBS19BL-XY........................... J.8
SS2S6-M0.............................. A.16
SSM2S6-3X............................ A.16
SSM2S6-3X0.......................... A.16
SSM2S6-C.............................. A.16
SSM2S6-C0............................ A.16
SSM2S6-M............................. A.16
SSM3S8-3X............................ A.16
SSM3S8-3X0.......................... A.16
SSM3S8-C.............................. A.16
SSM3S8-C0............................ A.16
SSM3S8-M............................. A.16
SSM3S8-M0........................... A.16
SSMLP-3X.............................. A.18
SSMLP-C................................ A.18
SSMLP-M............................... A.18
SSMTA-C................................ A.16
SSMTA-M............................... A.16
ST14-075-60BK.......................C.6
ST15-075-66GRYL...................C.6
ST17-075-66BR.......................C.6
ST17-075-66BU.......................C.6
ST17-075-66GR.......................C.6
ST17-075-66GY.......................C.6
ST17-075-66OR.......................C.6
ST17-075-66RD.......................C.6
ST17-075-66VI.........................C.6
ST17-075-66WH......................C.6
ST17-075-66YL........................C.6
ST35-075-66BR.......................C.5
ST35-075-66BU.......................C.5
ST35-075-66GR.......................C.5
ST35-075-66GY.......................C.5
ST35-075-66OR.......................C.5
ST35-075-66RD.......................C.5
ST35-075-66VI.........................C.5
ST35-075-66WH......................C.5
ST35-075-66YL........................C.5
ST43-075-66BK.......................C.5
ST88-075-66BK.......................C.4
ST88-100-108BK.....................C.4
ST88-150-66BK.......................C.4
ST88-200-66BK.......................C.4
T
T70KW2IW.............................. J.11
T70KW4IW.............................. J.11
TTS-35R3-0...........................H.62
TTS-35RX0.............................H.62
W
WB89D..................................... J.8
Call 866-405-6654 or visit www.panduit.com/stronghold
M.7
Panduit is a global leader in
cabling and communication products,
delivering end-to-end solutions in support of
demanding electrical and networking requirements.
Panduit Catalogs
Industrial Electrical Solutions
ELCB31--SA-ENG
• Bundle
Cable Ties
Cable Accessories
Stainless Steel Cable Ties
and Accessories
• Route/Protect
Wiring Duct
Abrasion Protection
Cable Management
• Terminate
Terminals
Power Connectors
Grounding Connectors
• Identification and
Safety Solutions
Labeling Systems
Labels
Pre-Printed and
Write-On Markers
Permanent Identification
Lockout/Tagout and
Safety Solutions
• Keystone Cabling
Systems
Network and Infrastructure Solutions
NCCB93--SA-ENG
• Copper Systems
• Fiber Systems
• Faceplates, Outlet Frames
and Surface Mount
Boxes
• Keystone Cabling Systems
• Zone Cabling
• Cable Routing Systems
• Surface Raceway
M.8
• Cabinets, Racks and
Cable Management
Systems
• Power Management
• Grounding and Bonding
• Identification Products
• Cable Management
Accessories
Order number of pieces required, in multiples of Standard Package Quantity.
Panduit Corporate
World Headquarters
Tinley Park, Illinois 60487
To learn more about Panduit’s
full contractor offering visit
www.panduit.com or contact
Customer Service: 800-777-3300
© 2020 Panduit Corp.
ALL RIGHTS RESERVED
Printed in the U.S.A.
Catalog Number ELCB32—SA-ENG