S14-120-L0

S14-120-L0

  • 厂商:

    PANDUIT

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
S14-120-L0 数据手册
Commercial Construction Pocket Guide PANDUIT NetKey® Table of Contents Contractor Grade Solutions for Electrical and Networking Installations A. StrongHold™ Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . . A.1 - A.18 StrongHold™ Cable Tie Accessories Panduit brings you three strong brands in a collaborative approach B. StrongHold™ Stainless Steel Cable Ties . . . . . . . . . . . B.1 - B.8 to provide a competitive advantage to our customers in the con- C. StrongHold™ PVC Electrical Tape . . . . . . . . . . . . . . . . . . C.1 - C.6 tractor market space. Panduit offers a unique understanding of the D. Panduit Specialty Tapes . . . . . . . . . . . . . . . . . . . . . . . . . . D.1 - D.4 complexities of infrastructure construction and continually develops new application systems focused on meeting the constantly adapting E. StrongHold™ Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . E.1 - E.9 installation and maintenance needs of our customers. Whether the F. StrongHold™ Pigtails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F.1 - F.4 solution is for electrical or networking systems Panduit continually G. StrongHold™ Wire Marker Books . . . . . . . . . . . . . . . . . . G.1 - G.3 strives to bring you the best option for your application needs. H. StrongHold™ Supports & Fasteners . . . . . . . . . . . . . . . H.1 - H.29 Cable/Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.2 - H.19 Beam/Purlin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.20 - H.31 Hangers/Hanging Systems . . . . . . . . . . . . . . . . . . . H.32 - H.33 Stud Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.34 - H.50 Communication/Low Voltage . . . . . . . . . . . . . . . . . H.51 - H.66 Dry Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.67 - H.68 Acoustical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.69 - H.78 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H.79 - H.82 Panduit® Panduit is committed to providing our contractor partners a comprehensive assortment of products, programs, and services. Our collaborative approach addresses the greatest business challenges for the contractor community and provides a competitive advantage in your market space. StrongHold™ StrongHold™ helps our customers achieve their goals by providing I. Panduit Duct Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I.1 - I.2 an assortment of reliable, convenient and economical electrical J. NetKey® Cabling Systems . . . . . . . . . . . . . . . . . . . . . . . J.1 - J.16 products, delivering the quality standards electrical contractors can rely on. We are continually adding to our portfolio in order to provide K. Convenient Sizing Information . . . . . . . . . . . . . . . . . . . . K.1 - K.8 the most comprehensive offering of innovative electrical solutions L. Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . L.1 - L.19 that contractors can trust to get the job done. M. Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M.1 - M.7 NetKey® The NetKey® Copper and Fiber Cabling System provides a complete, standards compliant cabling infrastructure solution for voice, data and video applications. NetKey® Modules feature the universal “keystone” design and are compatible with a wide assortment of modular patch panels, faceplates and surface mount boxes. For complete program details, go to www.panduit.com or contact Customer Service at 800.777.3300. All programs and benefits subject to terms and conditions. ii Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold iii Cable Ties StrongHold™ offers contractors economical cable tie options for commercial construction including locking, releasable, and clamp ties. The line features a variety of plenum-rated nylon cable ties in natural, UV weather resistant black, and red, suitable for both indoor and outdoor applications. In addition, StrongHold™ offers a comprehensive assortment of cable tie mounts to complement our cable tie offering. Our mounts feature Adhesive Back Mounts and Screw Mounts in natural and black nylon materials, suitable for securing wires and cables quickly. Combined with StrongHold™ cable ties, our mounts offer you the best routing solution for your application needs. StrongHold ™ Cable Ties StrongHold™ Contractor Grade Cable Ties Application Environments 95+ Part Numbers • Suitable for general purpose, light commercial, contractor, residential and HVAC applications • No controlled tension during installation (not for use with cable tie installation tool) Materials/Environment • Nylon 6.6 in natural and in UV weather resistant black – Suitable for Plenum spaces – Black UV suitable for outdoor use Tie Construction (Cross-Sectional Area) • Available in Miniature, Intermediate, Standard, Light Heavy, and Heavy – Loop tensile strength 18, 40, 50, 120 and www.panduit.com/StrongHold 175 lbs. – Tie lengths 3.9" to 48.0" – Bundle diameters to 14.3" Product Offering Operating Temperature • -40°C to 85°C Compliance Ratings Project Based Pricing — Application Support — Pricing A.1 Order number of pieces required, in multiples of Standard Package Quantity. cULus Listed to UL 62275 Type 2,21 Value Price Model Call 866-405-6654 or visit www.panduit.com/stronghold A.2 Cable Ties Cable Ties Part Number Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Miniature Cable Ties 18 lbs (80N) S4-18-C S4-18-M S4-18-C0 S4-18-M0 S6-18-C S6-18-M S6-18-C0 S6-18-M0 S8-18-C S8-18-M S8-18-C0 S8-18-M0 3.94 (100) 3.94 (100) 3.94 (100) 3.94 (100) 6.30 (160) 6.30 (160) 6.30 (160) 6.30 (160) 7.87 (200) 7.87 (200) 7.87 (200) 7.87 (200) 0.87 (22) 0.87 (22) 0.87 (22) 0.87 (22) 1.57 (40) 1.57 (40) 1.57 (40) 1.57 (40) 2.09 (53) 2.09 (53) 2.09 (53) 2.09 (53) S12-40-C 5.51 (140) 5.51 (140) 5.51 (140) 5.51 (140) 7.87 (200) 7.87 (200) 7.87 (200) 7.87 (200) 11.81 (300) S12-40-M 11.81 (300) S12-40-C0 11.81 (300) S12-40-M0 11.81 (300) S15-40-C 14.57 (370) S15-40-C0 14.57 (370) S6-40-M S6-40-C0 S6-40-M0 S8-40-C S8-40-M S8-40-C0 S8-40-M0 A.3 1.30 (33) 1.30 (33) 1.30 (33) 1.30 (33) 2.09 (53) 2.09 (53) 2.09 (53) 2.09 (53) 2.99 (76) 2.99 (76) 2.99 (76) 2.99 (76) 4.02 (102) 4.02 (102) Color AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Miniature Cable Ties 18 lbs (80N) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 0.10 (2.5) 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 Intermediate Cable Ties 40 lbs (178 N) S6-40-C StrongHold ™ Cable Tie Part Numbers 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) 0.14 (3.6) Intermediate Cable Ties 40 lbs (178 N) 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 100 Black 3 No 3 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.4 Cable Ties Cable Ties Part Number Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Standard Cable Ties 50 lbs (222 N) S5-50-C S12-50-C 4.72 (120) 4.72 (120) 4.72 (120) 4.72 (120) 6.30 (160) 6.30 (160) 6.30 (160) 6.30 (160) 7.40 (188) 7.40 (188) 7.40 (188) 7.40 (188) 7.40 (188) 8.46 (215) 8.46 (215) 8.46 (215) 8.46 (215) 8.46 (215) 8.46 (215) 11.81 (300) S12-50-M 11.81 (300) S12-50-C0 11.81 (300) S12-50-M0 11.81 (300) S12-50-C2 11.81 (300) S15-50-C 14.57 (370) S5-50-M S5-50-C0 S5-50-M0 S6-50-C S6-50-M S6-50-C0 S6-50-M0 S7-50-C S7-50-M S7-50-C0 S7-50-M0 S7-50-C2 S8-50-C S8-50-M S8-50-C0 S8-50-M0 S10-50-C S10-50-C0 A.5 StrongHold ™ Cable Tie Part Numbers 0.94 (24) 0.94 (24) 0.94 (24) 0.94 (24) 1.50 (38) 1.50 (38) 1.50 (38) 1.50 (38) 1.81 (46) 1.81 (46) 1.81 (46) 1.81 (46) 1.81 (46) 2.09 (53) 2.09 (53) 2.09 (53) 2.09 (53) 2.09 (53) 2.09 (53) 2.99 (76) 2.99 (76) 2.99 (76) 2.99 (76) 2.99 (76) 4.02 (102) Color AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Standard Cable Ties 50 lbs (222 N) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 0.19 (4.8) 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Red 3 No 3 3 100 Natural 3 3 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Natural 3 No 3 3 100 Black 3 3 3 3 100 Natural 3 No 3 3 1000 Natural 3 No 3 3 100 Black 3 3 3 3 1000 Black 3 3 3 3 100 Red 3 No 3 3 100 Natural 3 No 3 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.6 Cable Ties Cable Ties Part Number A.7 StrongHold ™ Cable Tie Part Numbers Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Color AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Standard Cable Ties 50 lbs (222 N) (continued) Standard Cable Ties 50 lbs (222 N) (continued) S15-50-M 14.57 (370) 4.02 (102) 0.19 (4.8) 1000 Natural 3 No 3 3 S15-50-C0 14.57 (370) 4.02 (102) 0.19 (4.8) 100 Black 3 3 3 3 S15-50-M0 14.57 (370) 4.02 (102) 0.19 (4.8) 1000 Black 3 3 3 3 S15-50-C2 14.57 (370) 4.02 (102) 0.19 (4.8) 100 Red 3 No 3 3 S17-50-C 16.90 (430) 4.33 (110) 0.19 (4.8) 100 Natural 3 No 3 3 S17-50-M 16.90 (430) 4.33 (110) 0.19 (4.8) 1000 Natural 3 No 3 3 S17-50-C0 16.90 (430) 4.33 (110) 0.19 (4.8) 100 Black 3 3 3 3 S17-50-M0 16.90 (430) 4.33 (110) 0.19 (4.8) 1000 Black 3 3 3 3 S21-50-C 20.87 (530) 5.51 (140) 0.19 (4.8) 100 Natural 3 No 3 3 S21-50-M 20.87 (530) 5.51 (140) 0.19 (4.8) 1000 Natural 3 No 3 3 S21-50-C0 20.87 (530) 5.51 (140) 0.19 (4.8) 100 Black 3 3 3 3 S21-50-M0 20.87 (530) 5.51 (140) 0.19 (4.8) 1000 Black 3 3 3 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.8 Cable Ties Cable Ties Part Number Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Color Light Heavy Cable Ties 120 lbs (534 N) A.9 StrongHold ™ Cable Tie Part Numbers AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Light Heavy Cable Ties 120 lbs (534 N) S14-120-L 14.49 (368) 4.02 (102) 0.30 (7.6) 50 Natural 3 No 3 3 S14-120-TL 14.49 (368) 4.02 (102) 0.30 (7.6) 250 Natural 3 No 3 3 S14-120-L0 14.49 (368) 4.02 (102) 0.30 (7.6) 50 Black 3 3 3 3 S14-120-TL0 14.49 (368) 4.02 (102) 0.30 (7.6) 250 Black 3 3 3 3 S18-120-L 17.71 (450) 5.12 (130) 0.30 (7.6) 50 Natural 3 No 3 3 S18-120-L0 17.71 (450) 5.12 (130) 0.30 (7.6) 50 Black 3 3 3 3 S21-120-L 20.98 (533) 5.51 (140) 0.30 (7.6) 50 Natural 3 No 3 3 S21-120-C 20.98 (533) 5.51 (140) 0.30 (7.6) 100 Natural 3 No 3 3 S21-120-L0 20.98 (533) 5.51 (140) 0.30 (7.6) 50 Black 3 3 3 3 S21-120-C0 20.98 (533) 5.51 (140) 0.30 (7.6) 100 Black 3 3 3 3 S24-120-Q 23.62 (600) 6.89 (175) 0.30 (7.6) 25 Natural 3 No 3 3 S24-120-L 23.62 (600) 6.89 (175) 0.30 (7.6) 50 Natural 3 No 3 3 S24-120-Q0 23.62 (600) 6.89 (175) 0.30 (7.6) 25 Black 3 3 3 3 S24-120-L0 23.62 (600) 6.89 (175) 0.30 (7.6) 50 Black 3 3 3 3 S30-120-X 29.53 (750) 8.58 (218) 0.30 (7.6) 10 Natural 3 No 3 3 S30-120-L 29.53 (750) 8.58 (218) 0.30 (7.6) 50 Natural 3 No 3 3 S30-120-X0 29.53 (750) 8.58 (218) 0.30 (7.6) 10 Black 3 3 3 3 S30-120-L0 29.53 (750) 8.58 (218) 0.30 (7.6) 50 Black 3 3 3 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.10 Cable Ties Cable Ties Part Number Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Color Heavy Cable Ties 175 lbs (778 N) A.11 StrongHold ™ Cable Tie Part Numbers AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Heavy Cable Ties 175 lbs (778 N) S18-175-L 17.71 (450) 5.20 (132) 0.35 (9.0) 50 Natural 3 No 3 3 S18-175-L0 17.71 (450) 5.20 (132) 0.35 (9.0) 50 Black 3 3 3 3 S21-175-L 20.86 (530) 5.51 (140) 0.35 (9.0) 50 Natural 3 No 3 3 S21-175-C 20.86 (530) 5.51 (140) 0.35 (9.0) 100 Natural 3 No 3 3 S21-175-L0 20.86 (530) 5.51 (140) 0.35 (9.0) 50 Black 3 3 3 3 S21-175-C0 20.86 (530) 5.51 (140) 0.35 (9.0) 100 Black 3 3 3 3 S24-175-L 24.02 (610) 7.36 (187) 0.35 (9.0) 50 Natural 3 No 3 3 S24-175-L0 24.02 (610) 7.36 (187) 0.35 (9.0) 50 Black 3 3 3 3 S31-175-L 30.55 (776) 8.98 (228) 0.35 (9.0) 50 Natural 3 No 3 3 S31-175-L0 30.55 (776) 8.98 (228) 0.35 (9.0) 50 Black 3 3 3 3 S32-175-L 32.12 (816) 9.41 (239) 0.35 (9.0) 50 Natural 3 No 3 (also UL181) 3 S32-175-L0 32.12 (816) 9.41 (239) 0.35 (9.0) 50 Black 3 3 3 (also UL181) 3 S36-175-L 35.91 (912) 10.35 (263) 0.35 (9.0) 50 Natural 3 No 3 (also UL181) 3 S36-175-L0 35.91 (912) 10.35 (263) 0.35 (9.0) 50 Black 3 3 3 (also UL181) 3 S40-175-X 40.16 (1020) 11.61 (295) 0.35 (9.0) 10 Natural 3 No 3 (also UL181) 3 S40-175-L 40.16 (1020) 11.61 (295) 0.35 (9.0) 50 Natural 3 No 3 (also UL181) 3 S40-175-X0 40.16 (1020) 11.61 (295) 0.35 (9.0) 10 Black 3 3 3 (also UL181) 3 S40-175-L0 40.16 (1020) 11.61 (295) 0.35 (9.0) 50 Black 3 3 3 (also UL181) 3 S48-175-L 48.03 (1220) 14.37 (365) 0.35 (9.0) 50 Natural 3 No 3 (also UL181) 3 S48-175-L0 48.03 (1220) 14.37 (365) 0.35 (9.0) 50 Black 3 3 3 (also UL181) 3 S48-175-L8 48.03 (1220) 14.37 (365) 0.35 (9.0) 50 Gray 3 No 3 (also UL181) 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.12 Cable Ties Cable Ties Part Number Cable Ties Length In. (mm) Max. Bundle Dia. In. (mm) Width In. (mm) Std. Pkg. Qty. Color Cable Ties, Releasable, 50 lbs (222 N) AH-2 Plenum Rated UV Resistant cULus Listed 62275 Type 2,21 CE Declaration Cable Ties, Releasable, 50 lbs (222 N) SR8-50-C 7.87 (200) 1.97 (50) 0.19 (4.8) 100 Natural 3 No 3 3 SR8-50-C0 7.87 (200) 1.97 (50) 0.19 (4.8) 100 Black 3 3 3 3 Cable Ties, Clamp Style, 50 lbs (222 N) - Clamp Mount takes #10 / M5 Screw Cable Ties, Clamp Style, 50 lbs (222 N) Clamp Mount takes #10 / M5 Screw SC8-50-S10-C 7.87 (200) 1.85 (47) 0.19 (4.8) 100 Natural No No 3 3 SC8-50-S10-C0 7.87 (200) 1.85 (47) 0.19 (4.8) 100 Black No 3 3 3 Cable Ties, Clamp Style, 50 lbs (222 N) - Clamp Mount takes #10 / M5 Screw A.13 StrongHold ™ Cable Tie Part Numbers Cable Ties, Clamp Style, 50 lbs (222 N) Clamp Mount takes #10 / M5 Screw SC15-120-S25-L 14.96 (380) 3.86 (98) 0.30 (7.6) 50 Natural 3 No 3 3 SC15-120-S25-L0 14.96 (380) 3.86 (98) 0.30 (7.6) 50 Black 3 3 3 3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.14 Cable Tie Accessories Low Profile Cable Tie Anchor Mounts Low Profile Cable Tie Anchor Mounts Length In. (mm) Width In. (mm) Height In. (mm) SSMTA-M 0.75 (19.0) 0.38 (9.5) 0.20 (5.1) Nylon 6.6 SSMTA-C 0.75 (19.0) 0.38 (9.5) 0.20 (5.1) Nylon 6.6 Part Number Anchor Mounts Part Number Material Hole Diameter In. (mm) Mounting Method Std. Pkg. Qty. Std. Pkg. Qty. S*-18, S*-40, S*-50 0.17 (4.3) #8 (M4) Screw 1000 5000 S*-18, S*-40, S*-50 0.17 (4.3) #8 (M4) Screw 100 500 Used with Stronghold Cable Ties Anchor Mounts Standard Screw Applied Cable Tie Mounts Length In. (mm) Standard Screw Applied Cable Tie Mounts Width In. (mm) Height In. (mm) Material Cable Tie Mounts A.15 StrongHold ™ Cable Tie Accessories Part Numbers Used with Stronghold Cable Ties Hole Diameter In. (mm) Mounting Method Std. Pkg. Qty. Std. Pkg. Qty. Cable Tie Mounts SSM2S6-M 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) Nylon 6.6 S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 1000 5000 SSM2S6-C 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) Nylon 6.6 S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 100 500 SSM2S6-3X 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) Nylon 6.6 S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 30 300 SS2S6-M0 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) Weather Resistant Nylon 6.6 S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 1000 5000 SSM2S6-C0 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) Weather Resistant Nylon 6.6 S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 100 500 SSM2S6-3X0 0.63 (16.0) 0.43 (10.8) 0.28 (7.0) S*-18, S*-40, S*-50 0.29 (7.1) #6 (M3) Screw 30 300 SSM3S8-M 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Weather Resistant Nylon 6.6 Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 1000 5000 SSM3S8-C 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 100 500 SSM3S8-3X 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 30 300 SSM3S8-M0 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Weather Resistant Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 1000 5000 SSM3S8-C0 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Weather Resistant Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 100 500 SSM3S8-3X0 0.86 (21.9) 0.61 (15.5) 0.37 (9.4) Weather Resistant Nylon 6.6 S*-18, S*-40, S*-50, S*-120 0.32 (8.1) #8 (M4) Screw 30 300 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.16 Cable Ties Accessories Low Profile Screw Applied Cable Tie Mounts Part Number Length In. (mm) Width In. (mm) Height In. (mm) Cable Tie Mounts Low Profile Screw Applied Cable Tie Mounts Material Used with Stronghold Cable Ties Hole Diameter In. (mm) Mounting Method Std. Pkg. Qty. Std. Pkg. Qty. Cable Tie Mounts SSMLP-M 0.75 (19.1) 0.50 (12.7) 0.12 (3.0) Nylon 6.6 S*-18, S*-40, S*-50 0.164 (4.2)* #8 (M4) Countersunk Screw 1000 5000 SSMLP-C 0.75 (19.1) 0.50 (12.7) 0.12 (3.0) Nylon 6.6 S*-18, S*-40, S*-50 0.164 (4.2)* #8 (M4) Countersunk Screw 100 500 SSMLP-3X 0.75 (19.1) 0.50 (12.7) 0.12 (3.0) Nylon 6.6 S*-18, S*-40, S*-50 0.164 (4.2)* #8 (M4) Countersunk Screw 30 300 Adhesive Backed Mounts Adhesive Backed Mounts Size (LxW) (mm) Size (LxW) (In) Material SMP12A-3X .787x.787 20x20 Nylon 6.6 S*-18, S*-40 30 300pcs SMP12A-C .787x.787 20x20 Nylon 6.6 S*-18, S*-40 100 1000pcs Part Number Cable Tie Mounts A.17 StrongHold ™ Cable Tie Accessories Part Numbers Used with Stronghold Cable Ties Std. Pkg. Qty. Std. Ctn. Qty. Cable Tie Mounts SMP12A-M .787x.787 20x20 Nylon 6.6 S*-18, S*-40 1000 5000pcs SMP16A-3X 1" X 1" 25x25 Nylon 6.6 S*-18, S*-40, S*-50 30 300pcs SMP16A-C 1" X 1" 25x25 Nylon 6.6 S*-18, S*-40, S*-50 100 1000pcs SMP16A-M 1" X 1" 25x25 Nylon 6.6 S*-18, S*-40, S*-50 1000 5000pcs SMP18A-3X 1.18x1.18 30x30 Nylon 6.6 S*-18, S*-40, S*-50 30 300pcs SMP18A-C 1.18x1.18 30x30 Nylon 6.6 S*-18, S*-40, S*-50 100 1000pcs SMP18A-M 1.18x1.18 30x30 Nylon 6.6 1000 5000pcs SMP12A-3X0 .787x.787 20x20 Nylon 6.6 (Black) S*-18, S*-40, S*-50 S*-18, S*-40 30 300pcs SMP12A-C0 .787x.787 20x20 Nylon 6.6 (Black) S*-18, S*-40 100 1000pcs SMP12A-M0 .787x.787 20x20 Nylon 6.6 (Black) S*-18, S*-40 1000 5000pcs SMP16A-3X0 1" X 1" 25x25 Nylon 6.6 (Black) S*-18, S*-40, S*-50 30 300pcs SMP16A-C0 1" X 1" 25x25 Nylon 6.6 (Black) S*-18, S*-40, S*-50 100 1000pcs SMP16A-M0 1" X 1" 25x25 Nylon 6.6 (Black) S*-18, S*-40, S*-50 1000 5000pcs SMP18A-3X0 1.18x1.18 30x30 Nylon 6.6 (Black) S*-18, S*-40, S*-50 30 300pcs SMP18A-C0 1.18x1.18 30x30 Nylon 6.6 (Black) S*-18, S*-40, S*-50 100 1000pcs SMP18A-M0 1.18x1.18 30x30 Nylon 6.6 (Black) S*-18, S*-40, S*-50 1000 5000pcs Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold A.18 Stainless Steel Cable Ties StrongHold ™ Stainless Steel Cable Ties StrongHold offers a comprehensive selection of stainless steel products such as Metal Locking Ties (IMLT) and Custom Length Strapping (IMS) in uncoated and fully coated options to deliver high performance, strength, and reliability against harsh environments. StrongHold™ Stainless Steel Cable Ties PANDUIT Application Environments Materials/Environment IMLTs: Available in AISI 304 stainless steel for general purpose applications and AISI 316L stainless steel for the most corrosive environments PANDUIT Product Offering Order number of pieces required, in multiples of Standard Package Quantity. MLTFCs: Epoxy polyester coating available in black only Made in China with non-DFARS Steel Tie Construction (Cross-Sectional Area) Available in standard and heavy Loop Tensile Strength: 100 to 200 Lbs. (445 to 890N) Product Availability Available on request 8-10 week lead time Application Support — Pricing B.1 66+ Part Numbers Suitable for the following verticals: • Chemical Plants and Refineries • Industrial Construction • Mining • Oil and Gas • MRO • Shipbuilding • General Applications requiring Cable Management Value Price Model Call 866-405-6654 or visit www.panduit.com/stronghold B.2 Stainless Steel Cable Ties Material Min Loop Tensile Strength (N) Length (mm)* Width (mm) StrongHold™ Self-Locking Cable Ties PANDUIT PANDUIT Part Number Max Bundle Min Bundle Diameter Diameter (mm) (mm) StrongHold ™ Stainless Steel Cable Tie Part Numbers Thickness (mm) Recommended Tool Std Pkg Qty Std Ctn Qty StrongHold™ Self-Locking Cable Ties 25 12.7 556 127 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 304 51 12.7 556 201 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT69S-C 304 69 12.7 556 259 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT102S-C 304 102 12.7 556 362 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT152S-C 304 152 12.7 556 521 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT203S-C 304 203 12.7 556 679 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT254S-C 304 254 12.7 556 838 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT304S-Q 304 304 12.7 556 998 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT355S-Q 304 355 12.7 556 1156 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT380S-Q 304 380 12.7 556 1250 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT25S-C6L 316L 25 12.7 556 127 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT51S-C6L 316L 51 12.7 556 201 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT69S-C6L 316L 69 12.7 556 259 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT102S-C6L 316L 102 12.7 556 362 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT152S-C6L 316L 152 12.7 556 521 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT203S-C6L 316L 203 12.7 556 679 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT254S-C6L 316L 254 12.7 556 838 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLT304S-Q6L 316L 304 12.7 556 998 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT355S-Q6L 316L 355 12.7 556 1156 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT380S-Q6L 316L 380 12.7 556 1250 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 25 125 IMLT51H-L 304 51 12.7 890 201 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT69H-L 304 69 12.7 890 259 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT102H-L 304 102 12.7 890 362 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT152H-L 304 152 12.7 890 521 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT203H-L 304 203 12.7 890 679 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT254H-L 304 254 12.7 890 838 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT304H-Q 304 304 12.7 890 998 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 25 125 IMLT355H-Q 304 355 12.7 890 1156 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 25 125 IMLT51H-L6L 316L 51 12.7 890 201 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT69H-L6L 316L 69 12.7 890 259 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT102H-L6L 316L 102 12.7 890 362 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT152H-L6L 316L 152 12.7 890 521 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT203H-L6L 316L 203 12.7 890 679 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT254H-L6L 316L 254 12.7 890 838 7.9 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 50 250 IMLT304H-Q6L IMLT355H-Q6L 316L 316L 304 355 12.7 12.7 890 890 998 1156 7.9 7.9 0.25 0.25 GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 25 25 125 125 B.3 PANDUIT 304 IMLT51S-C PANDUIT IMLT25S-C Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold B.4 Stainless Steel Cable Ties Material IMLTFC38S-C6L IMLTFC51S-C6L IMLTFC64S-C6L IMLTFC86S-C6L IMLTFC102S-C6L 316L 316L 316L 316L 316L 38 51 64 86 102 12.7 12.7 12.7 12.7 12.7 445 445 445 445 445 158 201 233 310 362 4.6 4.6 4.6 4.6 4.6 0.25 0.25 0.25 0.25 0.25 GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT 100 100 100 100 100 500 500 500 500 500 IMLTFC137S-C6L 316L 137 12.7 445 462 4.6 0.25 GS4MT-E, HTMT, PPTMT, ST2MT 100 500 IMLTFC152S-C6L IMLTFC203S-C6L IMLTFC38H-C6L IMLTFC51H-L6L IMLTFC64H-C6L IMLTFC69H-L6L IMLTFC86H-C6L IMLTFC102H-L6L IMLTFC137H-C6L IMLTFC152H-L6L IMLTFC203H-L6L 316L 316L 316L 316L 316L 316L 316L 316L 316L 316L 316L 152 203 38 51 64 69 86 102 137 152 203 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 445 445 890 890 890 890 890 890 890 890 890 521 679 158 201 233 259 310 362 462 521 679 4.6 4.6 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT GS4MT-E, HTMT, PPTMT, ST2MT, PBTMT 100 100 100 50 100 50 100 50 100 50 50 500 500 500 250 500 250 500 250 500 250 250 Call 866-405-6654 or visit www.panduit.com/stronghold B.6 Part Number Max Bundle Min Bundle Diameter Diameter (mm) (mm) Length (mm) Width (mm) StrongHold™ Self-Locking Fully Coated Cable Ties B.5 PANDUIT PANDUIT Min Loop Tensile Strength (N) StrongHold ™ Stainless Steel Cable Tie Part Numbers Thickness (mm) Recommended Tool Std Pkg Qty Std Ctn Qty StrongHold™ Self-Locking Fully Coated Cable Ties Order number of pieces required, in multiples of Standard Package Quantity. Stainless Steel Straps and Buckles Part Number Material Length M Strap Breaking Strength N StrongHold™ Metal Strapping (Uncoated) - Coil StrongHold™ Stainless Steel Straps and Buckles Part Numbers Min Bundle Diameter mm Width mm Thickness mm Recommended Installation Tool Std. Pkg. Qty. StrongHold™ Metal Strapping (Uncoated) - Coil IMS9.5T35-QR6L Stainless Steel Type 316L 25 1780 26 9.5 0.35 BT75SDT 1 IMS12T35-QR6L Stainless Steel Type 316L 25 2445 26 12 0.35 BT75SDT 1 IMS16T35-QR6L Stainless Steel Type 316L 25 3110 26 16 0.35 BT75SDT 1 IMS19T75-QR6L Stainless Steel Type 316L 25 4225 26 19 0.75 BT75SDT 1 StrongHold™ Metal Strapping (Coated with Epoxy Polyester) - Coil StrongHold™ Metal Strapping (Coated with Epoxy Polyester) - Coil IMSP9.5T35-QR6L Stainless Steel Type 316L 25 1780 26 9.5 0.35^ BT75SDT 1 IMSP12T35-QR6L Stainless Steel Type 316L 25 2445 26 12 0.35^ BT75SDT 1 IMSP16T35-QR6L Stainless Steel Type 316L 25 3110 26 16 0.35^ BT75SDT 1 ^Base material less coating Part Number Material Width mm StrongHold Buckles Part Description Std. Pkg. Qty. StrongHold™ Buckles ™ IMSBL9.5-C6L Stainless Steel Type 316L 9.5 Individual Buckle Style L for use with 9.5 mm strapping 100 IMSBL12-C6L Stainless Steel Type 316L 12 Individual Buckle Style L for use with 12 mm strapping 100 IMSBL16-C6L Stainless Steel Type 316L 16 Individual Buckle Style L for use with 16 mm strapping 100 IMSBE19-C6L Stainless Steel Type 316L 19 Individual Buckle Style E for use with 19 mm strapping 100 B.7 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold B.8 PVC Tape PVC Electrical Tape StrongHold offers a broad range of pressure-sensitive vinyl electrical tape suitable for a wide range of indoor and outdoor applications and temperatures. Whether your application calls for high end performance over a range of temperatures, primary insulation for splicing, phase identification or high resistance to sun, water, oil, acids, alkalis, and corrosive chemicals; StrongHold Heavy Duty, Professional Grade and General Purpose line of electrical tapes have you covered. Not sure which grade of tape is necessary for your application? Take a look at our chart to compare options. Professional Grade Heavy Duty ST35 ST88 General Purpose ST43 ST14 ST17 HEAVY DUTY PROFESSIONAL GENERAL PURPOSE 8.5 mil 7.0 mil 7.0 mil Thickness Low temperature rating 0°F -18°C 0°F -18°C 14°F -10°C High temperature rating 221°F 105°C 221°F 105°C 176°F 80°C Sticking power 2.2 N/cm TYP 2.2 N/cm TYP 1.6-1.8 N/cm 300% TYP 260% TYP 200% TYP 38 N/cm TYP 30 N/cm TYP 25 N/cm TYP Elongation Breaking strength Color C.1 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold C.2 PVC Electrical Tape StrongHold™ PVC Electrical Tape Application Environments 27+ Part Numbers • A primary insulation when used for splicing up 600 Volts • A protective outer jacket over splices in low temperature applications Product Types: – Heavy Duty – Professional Grade – General Purpose Materials/Environments • Pressure sensitive vinyl adhesives backed electrical tape Product Offering Suitable for a range of applications including: • A primary insulation when used for splicing up 600 Volts • A protective outer jacket over splices in low temperature applications – Cold resistant www.panduit.com/StrongHold – Flame Retardant – High dielectric strength – High elastic – Highly resistant to water, oil, acids, alkalies, corrosive chemicals, and ultraviolet rays Panduit® PVC Tape Part Numbers ST88 Heavy Duty Tape StrongHold ST88 Series Heavy Duty PVC Electrical Tape is a 0.21 mm (8.5 mil) is an all-weather, pressure sensitive vinyl electrical tape that applies easily and provides a high level of performance over a range of temperatures. The ST88 series product is flame retardant and cold resistant. ST88 is suitable as a primary insulation when used for splicing up 600 Volts and can be used as a protective outer jacket over splices in low temperature applications. Heavy Duty Electrical PVC Vinyl Tape Offering Part Number Case Qty Minimum Order Qty ST88-075-66BK 100 20 ST88-100-108BK 80 20 ST88-150-66BK 100 20 ST88-200-66BK 40 20 Color Thickness Dimension 3/4"x.0085"x66' Black 8.5 mil 1"x.0085"x108' 1.5"x.0085"x66' 2"x.0085"x66' Operating Temperature • ST88 , ST35 and ST43 Series: -18° C to 105° C • ST17 and ST14 Series: -10° C to 80° C • ST15: Up to 80° C Compliance Ratings C.3 • • • • UL 510, CSA C 22.2 No. 197 EN 60454-1-1, Type II Meets ASTM D-3005 Meets 2000/53/EC and RoHS 2011/65/EU Directives • Pd, Cd, Hg, Cr (VI) free Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold C.4 PVC Electrical Tape ST35 & ST43 Professional Grade Tape StrongHold ST35 Series Professional Grade PVC Electrical Tape is a 0.18 mm (7 mil) is a pressure sensitive vinyl electrical tape that applies easily and provides a high level of performance over a range of temperatures. The ST35 series product is flame retardant and cold resistant. ST35 is suitable as a primary insulation when used for splicing up 600 Volts and can be used as a protective outer jacket over splices in low temperature applications. Professional Grade Electrical PVC VInyl Tape Offering Case Qty Minimum Order Qty Color Thickness Dimension ST35-075-66BU 20 20 Blue 7 mil 0.75" x 0.007" x 66' ST35-075-66BR 20 20 Brown 7 mil 0.75" x 0.007" x 66' ST35-075-66GY 20 20 Gray 7 mil 0.75" x 0.007" x 66' Part Number ST35-075-66GR 20 20 Green 7 mil 0.75" x 0.007" x 66' ST35-075-66OR 20 20 Orange 7 mil 0.75" x 0.007" x 66' ST35-075-66RD 20 20 Red 7 mil 0.75" x 0.007" x 66' ST35-075-66VI 20 20 Violet 7 mil 0.75" x 0.007" x 66' ST35-075-66WH 20 20 White 7 mil 0.75" x 0.007" x 66' ST35-075-66YL 20 20 Yellow 7 mil 0.75" x 0.007" x 66' ST43-075-66BK 20 100 Black 7 mil 0.75" x 0.007" x 66' Panduit® PVC Tape Part Numbers ST14 & ST17 General Purpose Tape StrongHold ST14 & ST17 General Purpose PVC Electrical Tape is a 0.18 mm (7 mil), one sided rubber based, pressure sensitive adhesive glossy finish vinyl electrical tape. The ST17 series product is non-corrosive and has pressure-sensitive adhesive which eliminates the need for heat, moisture and or other catalysts to affect the application. The high elongation makes it easy to tear while having excellent conformability properties. The product is UL and CSA Listed, flame retardant, as well as cold resistant. ST14 & ST17 is suitable as an electrical insulation when insulation when used for splicing up 600 Volts or 80°C (176°F). ST15 General Purpose Tape StrongHold ST15 General Purpose PVC Electrical Tape is a 0.13 mm (5 mil), one sided coating of rubber based, pressure sensitive adhesive matte finish vinyl electrical tape. The ST15 series product is noncorrosive and has pressure-sensitive adhesive which eliminates the need for heat, moisture and or other catalysts to affect the application. The high elongation makes it easy to tear while having excellent conformability properties. The product is nonflammable. ST15 is suitable as an electrical insulation when used for splicing up 600 Volts or 80°C (176°F). General Purpose Electrical PVC Vinyl Tape Offering Case Qty Minimum Order Qty Color Thickness Dimension ST17-075-66BU 100 20 Blue 7 mil 0.75" x 0.007" x 66' ST17-075-66BR 100 20 Brown 7 mil 0.75" x 0.007" x 66' ST17-075-66GY 100 20 Gray 7 mil 0.75" x 0.007" x 66' ST17-075-66GR 100 20 Green 7 mil 0.75" x 0.007" x 66' ST17-075-66OR 100 20 Orange 7 mil 0.75" x 0.007" x 66' ST17-075-66RD 100 20 Red 7 mil 0.75" x 0.007" x 66' ST17-075-66YL 100 20 Violet 7 mil 0.75" x 0.007" x 66' ST17-075-66VI 100 20 White 7 mil 0.75" x 0.007" x 66' ST17-075-66WH 100 20 Yellow 7 mil 0.75" x 0.007" x 66' ST14-075-60BK 100 20 100 20 7 mil 5 mil 0.75" x 0.007" x 66' ST15-07566GRYL Black Yellow with Green Stripes Part Number C.5 Order number of pieces required, in multiples of Standard Package Quantity. 0.75" x 0.005" x 66' Call 866-405-6654 or visit www.panduit.com/stronghold C.6 Hazard Tape Panduit offers an extensive assortment of blank and pre-printed hazard tapes with varying legends, colors, and dimensions for indoor and outdoor applications. Panduit Hazard Tapes feature highly visible legends with resistance from abrasion, chemicals, and UV light. Panduit ® Hazard Tape Part Numbers Underground Hazard Tapes • Used to warn of buried utility lines • HTU* parts are made of polyethylene tape • Supplied in rolls of 1000 feet (30.5 meters) Part Number Legend Color (Legend/ Background) Width (In.) Width (mm) Std. Pkg. Qty. Polyethylene HTU3G-T-M CAUTION TELEPHONE LINE BURIED BELOW Black/ Green CAUTION FIBER OPTIC CABLE BURIED BELOW Black/ Orange HTU3O-T-M CAUTION TELEPHONE LINE BURIED BELOW Black/ Orange HTU3R-E-M CAUTION ELECTRIC LINE BURIED BELOW Black/ Red HTU3Y-E-M CAUTION ELECTRIC LINE BURIED BELOW Black/ Yellow HTU60-TV CAUTION CABLE TV LINE BURIED BELOW Black/ Orange HTU6R-E CAUTION ELECTRIC LINE BURIED BELOW Black/ Red CAUTION BURIED FIBER OPTIC CABLE Black/ Orange HTU60-T CAUTION TELEPHONE LINE BURIED BELOW Black/ Orange HTU6Y-E CAUTION ELECTRIC LINE BURIED BELOW Black/ Yellow HTU6Y-G CAUTION GAS LINE BURIED BELOW Black/ Yellow CAUTION ELECTRIC LINE BURIED BELOW (English/French) Black/ Yellow HTU3O-FO-M HTU6O-FO 76.2 3.00 1 152.4 6.00 French Legend HTU3Y-EF D.1 Order number of pieces required, in multiples of Standard Package Quantity. 3.00 76.2 Call 866-405-6654 or visit www.panduit.com/stronghold 1 D.2 Underground Hazard Tapes ™ StrongHold Panduit ® Hazard CableTape Tie Part Numbers Detectable Underground Hazard Tapes Solid Color Adhesive Warning Tapes • Used • Used to warn of buried utility lines • HTU* parts are made of polyethylene tape • Supplied in rolls of 1000 feet (30.5 meters) Part Number Legend Color (Legend/ Background) Width (In.) Width (mm) Std. Pkg. Qty. Laminated Detectable Aluminum HTDU3B-W CAUTION WATER LINE BURIED BELOW Black/ Blue CAUTION FIBER SEWER LINE BURIED BELOW Black/ Green HTDU30-FO CAUTION FIBER OPTIC CABLE BURIED BELOW Black/ Orange HTDU3O-T CAUTION TELEPHONE LINE BURIED BELOW Black/ Orange HTDU3R-E CAUTION ELECTRIC LINE BURIED BELOW Black/ Red HTDU60-FO CAUTION FIBER OPTIC CABLE BURIED BELOW Black/ Orange HTDU3G-S to identify hazards, traffic lanes, etc. • Installs faster and lasts longer than paint • Durable vinyl continuous tape for indoor use 3.00 Part Number Color HT2-BLU Blue HT2-GRN Green HT2-ORN Orange HT2-RED Red HT2-YEL Yellow HT2-WHT White 1 6.00 Color HT2S-RED-WHT Red/White • Used to warn of temporary hazards • Attaches easily to posts, walls, etc. • Highly visible 2.00" (51.0mm) black legends • Made of non-adhesive polyethylene film • Supplied in rolls of 1000 feet (30.5 meters) HT3S-BLK-YEL Black/Yellow HT3S-RED-WHT Red/White D.3 HTB3-DNE-M CAUTION DO NOT ENTER HTB3-HV-M CAUTION HIGH VOLTAGE 2.00 50.8 180.00 55.0 1 Roll Length (Ft.) Roll Length (m) Std. Pkg. Qty. 54.00 16.5 1 Width (In.) Width (mm) 2.00 50.8 3.00 76.2 on yellow background Color (Legend/ Background) Black/ Yellow Std. Pkg. Qty. 152.4 Barricade Tapes Legend Roll Length (m) • Self-adhesive striped warning/hazard tape • Color coded for quick indentification • Can be used in place of paint • Durable vinyl continuous tape for indoor use Black/Yellow CAUTION Roll Length (Ft.) Striped Hazard Tapes HT2S-BLK-YEL HTB3-C-M Width (mm) 76.2 Part Number Part Number Width (In.) Width (In.) Width (mm) Std. Pkg. Qty. 3.00 76.2 1 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold D.4 Terminals StrongHold ™ Terminal Part Numbers StrongHold offers a vast variety of contractor grade terminals, disconnects, and splices with multiple sizes and insulation options. Contractor grade terminals are reliable and economical options that withstand a wide range of general purpose applications. Ring Terminal American Wire Gauge Circular Mil Male Disconnect Nylon Insulated Quick Connect Tab EDNF18-187MB-Q Max Temperature PIN Diagram Strip Length 25 pc 15_piggy back disconnects_vinyl 01_ring terminal_na bullet _vinyl 04_fork terminal insulated_vinyl disconnects_nylon Male Bullet Ring Terminal ring terminal_vinyl locking fork terminal_na E.1 25 EV6-56R-Q #6 Blue 5/16" 25 EV8-8R-Q #8 Red #8 25 EV8-12R-Q #8 Red 1/2 25 EV8-14R-Q #8 Red 1/4" 25 EV8-38R-Q #8 Red 3/8" 25 EV8-56R-Q #8 Yellow 5/16" 25 EV10-10RB-Q #12-10 Yellow #10 25 EV10-12RB-Q #12-10 Yellow 1/2" 25 25 .145" 3.7mm INSUL. DIA. MAX EV10-38RB-Q #12-10 Yellow 3/8" 25 EV10-56RB-Q #12-10 Yellow 5/16" 25 EV10-6RB-Q #12-10 Yellow #6 25 EV10-8RB-Q #12-10 Yellow #8 25 EV14-10RB-Q* #16-14 Blue #10 25 EV14-14RB-Q* #16-14 Blue 1/4" 25 EV14-38RB-Q #16-14 Blue 3/8 25 EV14-56RB-Q* #16-14 Blue 5/16" 25 EV14-6RB-Q* #16-14 Blue #6 25 EV14-8RB-Q* #16-14 Blue #8 25 EV18-8RB-Q* #22-18 Red #8 25 EV18-10RB-Q* #22-18 Red #10 25 EV18-14RB-Q* #22-18 Red 1/4" 25 EV18-56RB-Q* #22-18 Red 5/16" 25 EV18-6RB-Q*019_male 019_male #22-18 bullet disconnects_vinyl bullet disconnects_vinyl Red #6 25 Made in Taiwan 6 13056 34228 6 See Panduit.com for individual part compliance and tooling options. All parts are ROHS compliant. 019_male bullet disconnects_vinyl 019_male bullet disconnects_vinyl 020_butt slice_na 021_butt splice_vinyl 020_butt slice_na 010_female disconnect _na 06_locking fork terminal_vinyl 07_narrow _vinyl 08_female disconnect_na 09_female disconnect_na 03_fork terminal_na 019_male fork bullet disconnects_vinyl 04_fork terminal insulated_vinyl 05_locking fork terminal 020_butt slice_na 021_butt splice_vinyl non-insulated Narrow Fork Terminal 022_step-down splice_vinyl splice_vinyl 021_butt022_step-down splice_vinyl Locking Fork Terminal 023_quick 023_quicksplice_vinyl splice_vinyl terminal_vinylDown 07_narrow fork _vinyl Butt Splice 06_locking forkStep Splice 011_female disconnect_vinyl 024_Pin Terminal_vinyl 024_Pin Terminal_vinyl 022_step-down splice_vinyl 023_quick 013_male splice_vinyl disconnects_nylon 08_female disconnect_na 09_female disconnect_na Quick Splice 024_Pin Terminal_vinyl 024_Pin Terminal_vinyl 022_step-down 022_step-down splice_vinyl splice_vinyl 023_quick023_quick splice_vinyl splice_vinyl 021_butt splice_vinyl 016_female bullet15_piggy back disconnects_vinyl 017_female bullet back disconnects_vinyl 013_male disconnects_nylon 014_male disconnects_nylon disconnects_vinyl 014_male 15_piggy disconnects_vinyl 011_female disconnect_vinyl 012_males013_male disconnect_na disconnects_nylon disconnects_vinyl Female Disconnect Male Disconnect 016_female bullet 15_piggy back 016_female 017_female bullet bullet disconnects_vinyl 014_male disconnects_vinyl Pin Terminal Blade disconnects_nylon disconnects_nylon disconnects_vinyl Terminal 024_Pin Terminal_vinyl 025_Blade025_Blade Terminal_vinyl Terminal_vinyl Piggy Back Disconnect Female Bullet bullet Wire Joint 018_male disconnects_nylon 026_Wire Joint_vinyl 026_Wire 017_female 018_male bullet Joint_vinyl bullet disconnects_vinyl disconnects_nylon 027_wire nuts 027_wire with spring_vinyl nuts with spring_vinyl locking fork terminal_vinyl Call 866-405-6654 or visit www.panduit.com/stronghold E.2 Order number of pieces required, in multiples of Standard Package Quantity. 025_Blade Terminal_vinyl 022_step-down splice_vinyl 07_narrow fork _vinyl 010_female disconnect _na 020_butt slice_na 020_butt slice_na 021_butt splice_vinyl 021_butt splice_vinyl 010_female disconnect _na 010_female disconnectdisconnect_vinyl _na 013_male disconnects_nylon 014_male disconnects_vinyl 011_female 011_female 012_males disconnect_vinyl disconnect_na 012_males disconnect_na terminal_na 05_locking fork terminal 04_fork terminal 01_ring insulated_vinyl 02_ring terminal_vinyl06_locking fork terminal_vinyl 03_fork terminal_na non-insulated 019_male 020_butt slice_na 018_male bullet bullet disconnects_vinyl 05_locking fork terminal non-insulated 3/8" 221°F 105°C MAX * -Q= Package quantity of 25 -L= Package quantity of 50 where applicable Fork Terminal Blue 9/32" 6.8mm Please note the following information regarding bag02_ring quantities: terminal_vinyl 03_fork terminal_na fork terminal_na #6 1/4" 01_ring terminal_na 02_ring terminal_vinyl 25 EV6-38R-Q Yellow Available in insulated and non-insulated options. See insulation options throughout this booklet for detailed information per product. sconnects_vinyl 25 1/2" #12-10 Terminals Legend 012_males disconnect_na #10 Blue EV10-14RB-Q Tab Size disconnect_vinyl Blue #6 .187"X.032" 4.8 x 0.8mm TAB SIZE Acceptable for Internal Wiring of Equipment Bullet #6 EV6-12R-Q 300V MAX Voltage Tool EV6-10R-Q 22-16 STR CU 0.5-1.5 mm² KST2000C Stud Size Stud/ Std.Pkg. Tab Size Qty. Color Ring Terminal, Insulated – Vinyl Navigating the StrongHold Packaging Icons Insulation Diagram Wire Range (AWG) Part Number 023_quick splice_vinyl 08_female disconnect_na 024_Pin Terminal_vinyl 025_Blade Terminal_vinyl 09_female disconnect_na 026_Wire Joint_vinyl 026_Wire Joint_vinyl 027_wire nuts with spring_vinyl 027_wire nutsTerminal_vinyl with spring_vinyl 025_Blade 026_Wire Joint_vinyl 016_female bullet disconnects_nylon 027_wire nuts with spring_vinyl 017_female bullet disconnects_vinyl 018_male bullet disconnects_nylon 012_males disco 15_piggy back d 018_male bullet disconnects_nylo 01_ring terminal_na 02_ring terminal_vinyl Terminals StrongHold ™ Terminals Part Numbers Ring Terminal Part Number Narrow Fork Terminal Wire Range (AWG) Color Stud/ Std.Pkg. Tab Size Qty. 05_locking fork terminal Part Number non-insulated 04_fork terminal insulated_vinyl E10-10RB-Q #12-10 Yellow #10 25 E10-14RB-Q #12-10 Yellow 1/4" 25 E10-6RB-Q #12-10 Yellow #6 25 E10-8RB-Q #12-10 Yellow #8 25 Blue #10 25 #16-14 Blue #4 25 E14-6RB-Q* #16-14 Blue #6 25 E14-8RB-Q* #16-14 Blue #8 25 E14-10RB-Q* 02_ring terminal_vinyl E14-4RB-Q* #16-14 03_fork terminal_na E18-10RB-Q* #22-18 Red E18-4RB-Q* #22-18 E18-6RB-Q* #22-18 #22-18 E18-8RB-Q* 04_fork terminal insulated_vinyl 05_locking fork terminal non-insulated 01_ring terminal_na #10 25 Red #4 25 Red #6 25 Red #8 25 07_narrow fork _vinyl 02_ring terminal_vinyl Part Number Color Stud/ Std.Pkg. Tab Size Qty. 04_fork terminal insulated_vinyl Fork Terminal, Insulated – Vinyl 07_narrow fork _vinyl #10 25 Yellow #8 25 EV14-10FNB-Q #16-14 Blue #10 25 EV14-6FNB-Q #16-14 Blue #6 25 Blue #8 25 Color Stud/ Std.Pkg. Tab Size Qty. 09_female disconnect_na #16-14 Locking Fork Terminal 02_ring terminal_vinyl Part Number 03_fork terminal_na Wire Range (AWG) Locking Fork Terminal, Insulated – Vinyl 05_locking fork terminal non-insulated EV10-10LFB-Q #12-10 Yellow #10 25 EV10-14LFB-Q #12-10 Yellow 1/4" 25 EV10-6LFB-Q #12-10 Yellow #6 25 EV10-8LFB-Q #12-10 Yellow #8 25 EV14-10LFB-Q* #16-14 Blue #10 25 EV14-6LFB-Q* #16-14 Blue #6 25 06_locking fork terminal_vinyl Yellow #10 25 EV14-8LFB-Q* #16-14 Blue #8 25 EV10-14FB-Q #12-10 Yellow 1/4" 25 EV18-10LFB-Q* #22-18 Red #10 25 #12-10 Yellow 5/16" 25 EV18-6LFB-Q* 03_fork terminal_na #22-18 Red #6 25 EV10-6FB-Q #12-10 Yellow #6 25 EV18-8LFB-Q* #22-18 Red #8 25 EV10-8FB-Q #12-10 Yellow #8 25 Locking Fork Terminal, Non-Insulated non-insulated EV14-10FB-Q* #16-14 Blue 07_narrow fork _vinyl #10 25 E10-10LFB-Q #12-10 Yellow #10 25 EV14-14FB-Q #16-14 Blue 1/4" 25 E10-14LFB-Q #12-10 Yellow 1/4" 25 EV14-6FB-Q* #16-14 Blue #6 25 E10-6LFB-Q #12-10 Yellow #6 25 EV14-8FB-Q* #16-14 Blue #8 25 E10-8LFB-Q #12-10 Yellow #8 25 EV18-10FB-Q* #22-18 Red #10 25 #16-14 Blue #10 25 EV18-6FB-Q* #22-18 Red 06_locking fork terminal_vinyl E14-10LFB-Q* #6 25 #16-14 Blue #6 25 #22-18 Red E14-6LFB-Q* #8 25 Red 25 #16-14 Blue 1/4" E14-8LFB-Q* #8 25 E18-10LFB-Q* #22-18 Red #10 25 E18-6LFB-Q* #22-18 Red #6 25 E18-8LFB-Q* #22-18 Red #8 25 08_female disconnect_na EV10-56FB-Q 05_locking fork terminal 08_female disconnect_na EV18-14FB-Q 09_female disconnect_na 06_locking fork terminal_vinyl 09_female disconnect_na #22-16 01_ring terminal_na 08_female disconnect_na 04_fork terminal insulated_vinyl 02_ring terminal_vinyl 09_female disconnect_na 05_locking fork terminal non-insulated Fork Terminal, Non-Insulated E.3 Yellow #12-10 #12-10 EV18-8FB-Q* fork terminal_na #12-10 EV10-10FB-Q 04_fork terminal insulated_vinyl 07_narrow fork _vinyl Stud/ Std.Pkg. Tab Size Qty. EV10-8FNB-Q 08_female disconnect_na 06_locking fork terminal_vinyl Wire 03_fork terminal_na Range (AWG) Color EV10-10FNB-Q EV14-8FNB-Q Fork Terminal 01_ring terminal_na Wire Range (AWG) 06_locking fork terminal_vinyl Narrow Fork Terminal, Insulated – Vinyl Ring Terminal, Non-Insulated 01_ring terminal_na 03_fork terminal_na E10-10FB-Q #12-10 Yellow #10 25 E10-14FB-Q #12-10 Yellow 1/4" 25 E10-6FB-Q #12-10 Yellow #6 25 E10-8FB-Q #12-10 Yellow #8 25 E14-10FB-Q* #16-14 Blue #10 25 E14-6FB-Q* #16-14 Blue #6 25 Female Disconnect Terminal, Insulated – Nylon E14-8FB-Q* #16-14 Blue #8 25 EDNF10-250FI-Q #12-10 #16-14 Blue 0.187" x 0.020" 25 #16-14 Blue 0.250" x 0.032" 25 female disconnect_fully vinyl EDNF18-188FIB-Q* female disconnect_fully nylon #22-18 Red 0.187" x 0.020" 25 EDNF18-250FIB-Q* Red 0.250" x 0.032" 25 Female Disconnect Terminal 07_narrow fork _vinyl 08_female disconnect_na 09_female disconnect_na Part Number E18-10FB-Q* #22-18 Red #10 25 EDNF14-188FIB-Q* E18-6FB-Q* #22-18 Red #6 25 EDNF14-250FIB-Q* E18-8FB-Q* #22-18 Red #8 25 female disconnect_vinyl Order number of pieces required, in multiples of Standard Package Quantity. locking fork terminal_vinyl Wire Range (AWG) #22-18 Color Stud/ Std.Pkg. Tab Size Qty. Yellow 0.250" x 0.032" Call 866-405-6654 or visit www.panduit.com/stronghold 25 E.4 ring terminal_vinyl Terminals fork terminal_na Female Disconnect Terminal Wire Range (AWG) Part Number 010_female disconnect _na 011_female disconnect_vinyl Stud/ Std.Pkg. Tab Size Qty. Color StrongHold ™ Terminals Part Numbers Piggy Back Disconnect Terminal 012_males disconnect_na Female Disconnect Terminal, Insulated – Vinyl #12-10 EDV14-188B-Q* #16-14 Blue 0.187" x 0.020" 25 EDV14-250B-Q* #16-14 Blue 0.250" x 0.032" 25 EDV18-188B-Q* #22-18 Red 013_male disconnects_nylon25 0.187" x 0.020" 012_males disconnect_na EDV18-250B-Q* #22-18 Red 0.250" x 0.032" 25 EDV10-250FIB-Q #12-10 Yellow 0.250" x 0.032" 25 EDV14-250FIB-Q #16-14 Blue 0.250" x 0.032" 25 EDV18-250FIB-Q #22-16 Red 0.250" x 0.032" 25 locking fork terminal_vinyl n n onnect_vinyl nnects_vinyl 011_female disconnect_vinyl 25 0.187" x 0.020" Blue disconnects_nylon disconnects_vinyl 0.250" x 0.032" male bullet 25 disconnect_vinyl ED18-188-Q* #22-18 Red 0.187" x 0.020" 25 ED18-250-Q* #22-18 Red 0.250" x 0.032" 25 017_female bullet Male Disconnect Terminal 010_female disconnect _na 011_female disconnect_vinyl Part Number Wire Range (AWG) 012_males disconnect_na Stud/ Std.Pkg. Tab Size Qty. Color 016_female bullet disconnects_nylon EDNF14-187MB-Q #16-14 Blue 0.187" x 0.032" 25 EDNF18-187MB-Q #22-16 Red 0.187" x 0.032" 25 EDNF10250FIMB-Q #12-10 EDNF14250FIMB-Q* 012_males disconnect_na 014_male disconnects_vinyl 011_female disconnect_vinyl 013_male disconnects_nylon EDNF18250FIMB-Q* Yellow 0.250" x 0.032" Blue #16-14 15_piggy back disconnects_vinyl #22-18 0.250" x 0.032" step-down splice_vinyl EDV14-187MB-Q #16-14 Blue 0.187" x 0.032" 25 #16-14 Blue 0.250" x 0.032" 25 #22-16 Red 0.187" x 0.032" 25 #22-18 Red 0.250" x 0.032" disconnects_vinyl EDV18-250M-Q* 018_male bullet disconnects_nylon ED14-250MB-Q* 012_males disconnect_na 017_female bullet disconnects_vinyl ED18-250MB-Q* #12-10 #16-14 #22-18 Bullet Std.Pkg. Qty. .156" / 3.9mm 25 EBNF18-4FIB-Q #22-16 Red .156" / 3.9mm 25 Red .156" / 3.9mm 25 Blue .156" / 3.9mm 25 male bullet_fully nylon Female Bullet Terminal, Insulated – Vinyl 017_female bullet disconnects_vinyl EBV18-4B-Q #22-16 EBV14-4B-Q #16-14 018_male bullet disconnects_nylon Male Bullet Terminal Part Number Wire Range (AWG) Color Bullet Std.Pkg. Qty. butt slice_na EBNF14-4FIM-Qbutt splice_vinyl #16-14 Blue .156" / 3.9mm 25 EBNF18-4FIM-Q Red .156" / 3.9mm 25 #16-14 Blue .156" / 3.9mm 25 #22-16 Red .156" / 3.9mm 25 #22-16 male bullet_fully nylon Male Bullet Terminal, Insulated – Vinyl 25 EBV18-4MB-Q 019_male bullet disconnects_vinyl 020_butt slice_na 021_butt splice_vinyl Butt Splice blade 25 terminal_vinyl Part Number pin terminal_vinyl Wire Range (AWG) Color Std.Pkg. Qty. Butt Splice, Insulated – Vinyl Yellow 0.250" x 0.032" step-down splice_vinyl Blue Red 0.250" x 0.032" 25 butt slice_na 25 0.250"019_male x 0.032" 25 bullet disconnects_vinyl butt splice_vinyl ESV10BX-Q #12-10 Yellow 25 ESV14BX-Q* #16-14 Blue 25 #22-18 Red 25 022_step-down splice_vinyl 023_quick splice_vinyl ESV18BX-Q* 020_butt slice_na 024_Pin Terminal_vinyl 021_butt splice_vinyl Butt Splice, Non-Insulated 018_male bullet disconnects_nylon 15_piggy back disconnects_vinyl E.5 Color 018_male bullet Male Disconnect Terminal, Non-Insulated ED10-250M-Q 25 Blue EBV14-4MB-Q #12-10 EDV18-187MB-Q 15_piggy back disconnects_vinyl 017_female bullet 0.250" x 0.032" #16-14 disconnects_nylon female bullet_full vinyl 25 EDV10-250M-Q EDV14-250M-Q* #22-18 EBNF14-4FIB-Q 15_piggy back disconnects_vinyl 014_male disconnects_vinyl Male Disconnect Terminal, Insulated – Vinyl 014_male disconnects_vinyl 016_female bullet disconnects_nylon 25 Red 25 0.250" x 0.032" female 25 bullet_full vinyl Yellow 0.250" x 0.032" 0.250" x 0.032" Male Bullet Terminal, Insulated – Nylon male bullet disconnect_vinyl Red 25 Blue Wire Range (AWG) Part Number Male Disconnect Terminal, Insulated – Nylon 018_male bullet disconnects_nylon Yellow 0.250" x 0.032" #16-14 Female Bullet Terminal 25 016_female bullet #12-10 Female Bullet Terminal, Insulated – Nylon Blue female disconnect_nylon Stud/ Std.Pkg. Tab Size Qty. 15_piggy back disconnects_vinyl #16-14 female disconnect_na 011_female disconnect_vinylEDV14-250P-Q* 012_males disconnect_na EDV18-250P-Q* 014_male disconnects_vinyl #16-14 15_piggy back disconnects_vinyl 014_male disconnects_vinylED14-250-Q* 017_female bullet disconnects_vinyl EDV10-250P-Q 010_female disconnect _na 013_male disconnects_nylon Female Disconnect Terminal, Non-Insulated ED14-188-Q* Color Piggy Back Disconnect Terminal, Insulated – Vinyl Yellow 0.250" x 0.032" EDV10-250-Q locking fork terminal_na Wire Range (AWG) Part Number 019_male bullet disconnects_vinyl 022_step-down splice_vinyl Order number of pieces required, in multiples of Standard Package Quantity. blade terminal_vinyl 023_quick splice_vinyl pin terminal_vinyl ES10B-Q #12-10 Yellow 25 ES14B-Q* #16-14 Blue 25 ES18B-Q* #22-18 Red 25 020_butt slice_na 021_butt splice_vinyl 025_Blade Terminal_vinyl 026_Wire Joint_vinyl 024_Pin Terminal_vinyl 027_wire nuts with spring_vinyl Call 866-405-6654 or visit www.panduit.com/stronghold E.6 Terminals Step Down Splice _vinyl 020_butt slice_na Part Number 019_male bullet disconnects_vinyl Blade Terminal 022_step-down splice_vinyl Wire Range (AWG) Color 021_butt splice_vinyl Std.Pkg. Qty. 019_male bullet disconnects_vinyl ESV10-ESV14-Q 25 #12-10 to 22-18, Yellow Yellow with Red Color Ring 25 #16-14 to 22-18, Blue 024_Pin Terminal_vinyl with Red Color Ring Blue 25 ESV6-ESV8-Q #6 to 8, Blue with Red Color Ring Blue 25 ESV8-ESV10-Q #8 to 12-10, Red with Yellow Color Ring Red 25 ESV8-ESV14-Q #8 to 16-14, Red with Blue Color Ring Red 25 ESV14-ESV18-Q 022_step-down splice_vinyl 023_quick splice_vinyl Quick Splice 025_Blade Terminal_vinyl 020_butt slice_na 026_Wire Joint_vinyl Part Number 021_butt splice_vinyl 025_Blade Terminal_vinyl 022_step-down splice_vinyl Color Std.Pkg. Qty. Red 25 Blue 25 Brown 25 EQSP10-Q #12-10 Yellow 25 #16-14 Blue 25 #22-18 Red 25 Color Std.Pkg. Qty. #22-14 Clear 25 #18 -12 Clear 25 #16-8 Clear 25 EDV18-87MB-Q 026_Wire Joint_vinyl #12-10 Yellow 25 EQSP14-Q #18-14 Blue 25 EQSP18-Q #22-18 Red 25 027_wire nuts with spring_vinyl Wire Joint 024_Pin Terminal_vinyl Part Number Wire Range (AWG) 026_Wire Joint_vinyl EJN314-412-Q 027_wire nuts with spring_vinyl Please note the following information regarding bag quantities: * -Q= Package quantity of 25 -L= Package quantity of 50 where applicable See Panduit.com for individual part compliance and tooling options. All parts are ROHS compliant. 024_Pin Terminal_vinyl 023_quick splice_vinyl 026_Wire Joint_vinyl Std.Pkg. Qty. EDV14-87MB-Q EJN418-212-Q 025_Blade Terminal_vinyl #18-14 EQSP10-18D-Q Color EDV10-11MB-Q EJN218-216-Q* #12-10 to 18-14 EQSP14D-Q* 021_butt splice_vinyl #22-16 Wire Range (AWG) Wire Joint, Insulated – Nylon Quick Splice, Insulated – Polypropylene EQSP18D-Q 023_quick splice_vinyl 027_wire nuts with spring_vinyl Wire Range (AWG) 021_butt splice_vinyl 024_Pin Terminal_vinyl Blade Terminal, Insulated – Vinyl #12-10 to 16-14, Yellow Yellow with Blue Color Ring ESV10-ESV18-Q 023_quick splice_vinyl Part Number 020_butt slice_na Step Down Splice, Insulated – Vinyl connects_vinyl ce_vinyl StrongHold ™ Terminals Part Numbers Pin Terminal 027_wire nuts with spring_vinyl Part Number Wire Range (AWG) Color Pin Std.Pkg. Diameter Qty. Pin Terminal, Insulated – Vinyl 024_Pin Terminal_vinyl EV10-P55-Q #12-10 Yellow 0.10" Dia. 25 EV14-P47B-Q* #16-14 Blue 0.07" Dia. 25 EV18-P47B-Q* #22-18 Red 0.07" Dia. 25 027_wire nuts with spring_vinyl E.7 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold E.8 Grounding Pigtails StrongHold ™ Grounding Pigtail Part Numbers Grounding Pigtails StrongHold offers an assortment of grounding pigtails, power tails, and hardware in a variety of configurations and lengths that meet a broad range of applications, increasing jobsite productivity and reliability. Navigating the StrongHold™ Packaging Icons 12 Solid SOLID AWG SOLID 12 Solid Stranded STRANDED Grounding Bonding Pigtail AWG 10" 254mm Total Length STRANDED 12 Stranded AWG SGPL12-10S-L 16mm (16mm) Strip Length 5/8" Strip Length 5/8" 12 1"25mm (25mm) Strip Length Strip Length 1" AWG #10-32 UNC Thread #10-32 UNC THREAD 50 pc SOLID 1" 25mm Strip Length #10-32 UNC THREAD PHILIPS DRIVE FLAT DRIVE 1/8" 3.2mm SQUARE DRIVE #10-32 UNC Thread #10-32 UNC THREAD PHILIPS Philips Drive DRIVE Made in USA E136227 GROUNDING AND BONDING EQUIPMENT Flat Drive FLAT DRIVE 1/8" 3.2mm 1/8" (3.2mm) Square Drive SQUARE DRIVE Grounding Pigtails Legend Part Number Wire Type SGPL12-7S-L Strip Length 12 AWG 6.5" One 1" Solid 25mm SGPL12-8S-L 12 AWG 8" One 1" Solid 25mm SGPL12-10S-L 12 AWG 10" One 1" Solid 25mm SGPL12-12S-L 12 AWG 12" One 1" Solid 25mm SGPL14-8S-L 14 AWG 8" One 1" Solid 25mm SGPS12-8SRF-L 12 AWG 8" One N/A Stranded SGPS12-8SRT-L 12 AWG 8" One 5/8" Stranded 16mm SGPS12-8FT-L 12 AWG 8" One 5/8" Stranded 16mm SGPSL12-8SFT-Q 12 AWG 8" Two 1" Solid & 25mm Stranded SGPSS12-8SFT-Q 12 AWG 8" Two 5/8" Stranded 16mm SGPSS12-8SFF-Q 12 AWG 8" Two N/A Stranded SGPSSL12-8S-Q 12 AWG 8" Three 1" Solid & 25mm Stranded SGPSSS12-8S-Q 12 AWG 8" Three 5/8" Stranded 16mm UL Recognized Processed Wires SGPS12-8FT-L10 12 AWG 8" One 5/8" Stranded 16mm SGPS12-8FT-L20 12 AWG 8" One 5/8" Stranded 16mm Grounding Screws GSC10-32-38-C N/A 3/8" N/A N/A Thread Forming Available in various Insulated Stranded Wires and Single and Dual-Gang Number Overall of Length Wires Wire Insulation Color/Part Color Std. Pkg. Qty. Green 50 Green 50 Green 50 Green 50 Green 50 Green 50 Green 50 Green 50 Green 25 Green 25 Green 25 Green 25 Green 25 White 50 Black 50 Green 100 GSH10-32-38-C N/A 3/8" N/A N/A Green 100 Note: 1. All the screws/terminals are compatible with #10-32 thread. 2. All the Processed Wires have Voltage rating of 600 V at 105 °C. 3. All the screws are compatible with Flat, Philips and 1/8" (3.2mm) Square Drive. Power Tails intended for use connecting up to 600 volt power GSH/GSC Ground Screws Flanged Spade Terminal and GSC Ground Screw F.1 Flanged Spade Terminal Ring Terminal and GSH Ground Screw Order number of pieces required, in multiples of Standard Package Quantity. Single Gang with One Stranded Wire Dual Gang with One Solid Wire Dual Gang Dual Gang with One Stranded Wire Call 866-405-6654 or visit www.panduit.com/stronghold F.2 Stainless Steel Cable Ties Books Wire Marker StrongHold Marker Books features an assortment of conveniently pocket-sized pre-printed and self-laminating write-on marker book solutions used to identify many electrical and network components in markets such as Electrical, Industrial, Electronic, and Network. Marker books come in a variety of legends or ink receptive material for customization. StrongHold ™ Wire Marker Part Numbers Pre-Printed Marker Books • Convenient, pocket-sized book •  Markers are perforated and can be torn in half to mark both ends of conductors • Terminal block markers are included to properly identify connectors • Ten pages of markers per book • Temperature range: -40°F to 170°F (-40°C to 77°C) Part Number Legend Total Markers Each Legend PCMB-1 0 thru 9 45 PCMB-2 A thru Z, 0 thru 15, +, -, / 10 PCMB-3 1 thru 45 10 PCMB-4 1, 2, 3 150 PCMB-5 A, B, C 150 PCMB-6 T1, T2, T3 150 PCMB-7 L1, L2, L3 150 PCMB-8 1 thru 15 16 thru 90 A thru Z, +, -, /, 0 6 4 2 PCMB-9 1, 2, 3, A, B, C L1, L2, L3, T1, T2, T3 45 30 PCMB-11 1 thru 30 15 PCMB-12 A thru Z + Blank (write-on) 15 8 7 21 PCMB-13 +, -, AC, DC POS, NEG, GND NEUT SPARE, Blank (write-on) 45 21 21 21 PCMB-14 46 thru 90 0, +, 1 thru 45 0 thru 33, A, B, C, +, -, L1, L2, L3, T1, T2, T3 0 thru 9 L1, L2, L3, T1, T2, T3 10 PCMB-15 PCMB-16 PCMB-25 Legend: Black Marker sizes: Std. Ctn. Qty. Min. Order Qty. Book(s) 10 10 15 10 10 45 15 Background: White Full size marker – 0.22" x 1.38" (5.60mm x 34.90mm). Maximum wire O.D., 0.38" (9.50mm). Half size marker – 0.22" x 0.69" (5.60mm x 17.40mm). Maximum wire O.D., 0.19" (4.70mm). Terminal block marker – 0.22" x 0.25" (5.60mm x 6.30mm). G.1 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold G.2 Cable Wire Marker Ties Books StrongHold™ Electrical/Network Supports and Fasteners Blank Self-Laminating Write-On Cable Marker Books • 10 pages of markers per book • Clear section of marker over laminates and protects printed legend • Markers have ink receptive area to allow handwritten legends Part Number Print-on Area (In.) In. mm In. mm PSCB-12Y 0.62 0.50 12.7 1.50 38.1 180 PSCB-13Y 0.75 1.50 38.1 3.00 76.2 40 PSCB-16Y 1.00 1.50 38.1 6.00 152.4 20 PSCB-3Y 0.75 1.00 25.4 3.00 76.2 60 PSCB-3YELY* 0.75 1.00 25.4 3.00 76.2 60 PSCB-5Y 1.00 1.00 25.4 5.00 127.0 30 PSCB-6Y 1.00 1.00 25.4 6.00 152.4 30 Width Length ™ Supports and StrongHold Cable Tie Fasteners Part Numbers StrongHold offers a complete line of supports and fasteners for the commercial and industrial construction market, providing customers everything they need to fix, route, secure, and manage power and communication cabling. Markers Std Std Per Pkg. Ctn. Book Book(s) Book(s) 1 10 *Yellow G.3 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold G.4 Supports & Fasteners Cable/Conduit StrongHold ™ Cable/Conduit Part Numbers Push-Fit Conduit Clips Snap-Close Conduit Clips • No fastener required to retain conduit • Static load capacity: - 100 lbs. in vertical position - 25 lbs. in horizontal position • No fastener required to retain conduit • Static load capacity: - 25 lbs. in vertical position - 15 lbs. in horizontal position • Available with 1/4" non-threaded mounting hole Image 1 Fits EMT (In.) Part Number Image 2 Image No. Fits EMT/ Rigid/IMC (In.) P6M 1 3/8* 100 P16M 1 1 100 P20M 1 1 1/4 P24M 1 1 1/2 Part Number Mounting Hole (In.) 1/4 non-threaded Std. Pkg. Qty. P8P 1/2 – 100 P12P 3/4 1/2 100 P16P 1 3/4 100 Std. Pkg. Qty. 100 100 P812M 1 1/2 – 3/4 P812M4I** 2 1/2 – 3/4 1/4-20 threaded 100 P32M 1 2 1/4 non-threaded 100 Conduit Clamps with Bolt • Conduit hanger available for 1/2" – 4" conduit • Bolt and nut (Phillips/flathead) provide positive securing feature • Available with threaded and non-threaded mounting hole 100 *Or 14-2 through 12-3 MC/AC cable. **Not UL or cUL listed. H.1 Fits Rigid/IMC (In.) Order number of pieces required, in multiples of Standard Package Quantity. Part Number Fits EMT (In.) Fits Rigid/IMC (In.) Mounting Hole (In.) Std. Pkg. Qty. PCD0B 1/2 3/8 – 1/2 1/4 non-threaded 100 PCD1B 3/4 3/4 1/4 non-threaded 100 PCD2B 1 1 1/4 non-threaded 100 PCD2.5B 1 1/4 — 1/4 non-threaded 100 PCD3B 1 1/2 1 1/4 1/4 non-threaded 100 PCD4B — 1 1/2 5/16 non-threaded 100 PCD5B 2 2 5/16 non-threaded 50 PCD6B 2 1/2 2 1/2 5/16 non-threaded 50 PCD7B 3 3 5/16 non-threaded 25 PCD8B 3 1/2 3 1/2 5/16 non-threaded 25 PCD9B 4 4 1/2 non-threaded 10 Call 866-405-6654 or visit www.panduit.com/stronghold H.2 Supports & Fasteners Cable/Conduit Snap-Close Conduit Clips with Beam Clamps – Bottom Mount StrongHold ™ Cable/Conduit Part Numbers Snap-Close Conduit Clips with Beam Clamps – Side Mount • Suspend conduit from bottom of beam • Will pivot 360° • Hammer-on installation • Static load capacity: 75 lbs. vertically Flange Thickness (In.) Fits EMT/Rigid/IMC (In.) Std. Pkg. Qty. P6M24 1/8 – 1/4 3/8 100 P6M58 5/16 – 1/2 3/8 100 Part Number P6M912 9/16 – 3/4 3/8 100 P812M24 1/8 – 1/4 1/2 – 3/4 100 Part Number P812M58 P812M912 5/16 – 1/2 9/16 – 3/4 1/2 – 3/4 1/2 – 3/4 Flange Thickness (In.) Fits EMT/Rigid/IMC (In.) Std. Pkg. Qty. P6M24SM 1/8 – 1/4 3/8 100 P6M58SM 5/16 – 1/2 3/8 100 100 P6M912SM 9/16 – 3/4 3/8 100 100 P812M24SM 1/8 – 1/4 1/2 – 3/4 100 5/16 – 1/2 1/2 – 3/4 100 P16M24 1/8 – 1/4 1 100 P812M58SM P16M58 5/16 – 1/2 1 100 P812M912SM 9/16 – 3/4 1/2 – 3/4 100 P16M912 9/16 – 3/4 1 100 P16M24SM 1/8 – 1/4 1 100 P20M24 1/8 – 1/4 1 1/4 100 P16M58SM 5/16 – 1/2 1 100 100 P16M912SM 9/16 – 3/4 1 100 100 P20M24SM 1/8 – 1/4 1 1/4 100 5/16 – 1/2 1 1/4 100 P20M58 P20M912 H.3 • Suspend conduit from side of beam • Will pivot 360° • Hammer-on installation • Static load capacity: 25 lbs. vertically 5/16 – 1/2 9/16 – 3/4 1 1/4 1 1/4 P24M24 1/8 – 1/4 1 1/2 100 P20M58SM P24M58 5/16 – 1/2 1 1/2 100 P20M912SM 9/16 – 3/4 1 1/4 100 P24M912 9/16 – 3/4 1 1/2 100 P24M24SM 1/8 – 1/4 1 1/2 100 P32M24 1/8 – 1/4 2 100 P24M58SM 5/16 – 1/2 1 1/2 100 P32M58 5/16 – 1/2 2 100 P24M912SM 9/16 – 3/4 1 1/2 100 P32M912 9/16 – 3/4 2 100 P32M24SM 1/8 – 1/4 2 100 P32M58SM 5/16 – 1/2 2 100 P32M912SM 9/16 – 3/4 2 100 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.4 Supports & Fasteners Stud Wall Stud-Mounted Box Support Brackets Mount with self-tapping screws found on page H.49! StrongHold ™ Stud Wall Part Numbers Floor-Mounted Box Support Bracket – Variable Height • Bracket to support electrical boxes from floor or channels • Break-away feature allows product to be used at three heights • Manufactured from pre-galvanized steel • User-supplied self-tapping screws attach box to bracket • Manufactured from pre-galvanized steel PSGB16A Std. Pkg. Qty. Part Number Description PSGB16A Mounts 2 1/2" deep electrical boxes to studs on 16" centers. 50 PSGB24A Mounts 2 1/2" deep electrical boxes to studs on 24" centers. 50 H.5 Order number of pieces required, in multiples of Standard Package Quantity. Part Number PFBS18 Description Std. Pkg. Qty. Box support bracket to mount electrical boxes at 12", 16", or 18" heights. Call 866-405-6654 or visit www.panduit.com/stronghold 50 H.6 Supports & Fasteners Cable/Conduit Push-Fit Conduit Clips with Beam Clamps ™ ™ StrongHold StrongHold Cable/Conduit Cable Tie Part Part Numbers Numbers Cable Clips • Available in bottom mount or side mount options • Will pivot 360° • Hammer-on installation • Static load capacity: - 25 lbs. vertically for bottom mount (Image 1) - 15 lbs. vertically for side mount (Image 2) Image 1 • Support MC, AC, or BX cable from #12 – #8 wire in horizontal or vertical position • No static load rating – for positioning only • Can also be used for flexible metallic tubing, armored cable, portable cables, and control tubes • See chart below for installation configurations Part Number PKX Image 2 Part Number H.7 Image No. Flange Thickness (In.) Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. Std. Pkg. Qty. Description Cable clip to support MC, AC, or BX cable from drop wire. Cable Size (In.) 100 #12 Wire #10 Wire #8 – #9 Wire P8P24 1 1/8 – 1/4 1/2 — 100 14-2 (0.43 – 0.48 O.D.) PKX PKX PKX P8P58 1 5/16 – 1/2 1/2 — 100 14-3 (0.45 – 0.50 O.D.) PKX PKX PKX P8P912 1 9/16 – 3/4 1/2 — 100 12-2 (0.47 – 0.51 O.D.) PKX PKX PKX P12P24 1 1/8 – 1/4 3/4 1/2 100 12-3 (0.49 – 0.54 O.D.) PKX PK8* PK8* P12P58 1 5/16 – 1/2 3/4 1/2 100 P12P912 1 9/16 – 3/4 3/4 1/2 100 P16P24 1 1/8 – 1/4 1 3/4 100 P16P58 1 5/16 – 1/2 1 3/4 100 P16P912 1 9/16 – 3/4 1 3/4 100 P8P24SM 2 1/8 – 1/4 1/2 — 100 P8P58SM 2 5/16 – 1/2 1/2 — 100 P8P912SM 2 9/16 – 3/4 1/2 — 100 P12P24SM 2 1/8 – 1/4 3/4 1/2 100 P12P58SM 2 5/16 – 1/2 3/4 1/2 100 P12P912SM 2 9/16 – 3/4 3/4 1/2 100 P16P24SM 2 1/8 – 1/4 1 3/4 100 P16P58SM 2 5/16 – 1/2 1 3/4 100 P16P912SM 2 9/16 – 3/4 1 3/4 100 Order number of pieces required, in multiples of Standard Package Quantity. *See PK8 on Page A.7. Call 866-405-6654 or visit www.panduit.com/stronghold H.8 Supports & Fasteners Cable/Conduit Conduit Clips ™ ™ StrongHold StrongHold Cable/Conduit Cable Tie Part Part Numbers Numbers Multi-Function Clip Assemblies • Support conduit from drop wire, rod, or flange • No static load rating – for positioning only • Can also be used for flexible metallic tubing, armored cable, portable cables, and control tubes • See chart below for installation configurations Part Number Std. Pkg. Qty. Description PK8 Conduit clip to support 1/2" EMT from drop wire, rod, or flange. 100 PK12 Conduit clip to support 3/4" EMT from drop wire, rod, or flange. 100 PK16* Conduit clip to support 1" EMT from drop wire, rod, or flange. 100 PK20* Conduit clip to support 1 1/4" EMT drop wire, rod, or flange. 100 Image 1 • Components and assemblies used to secure conduit and devices to drop wire, rod, or flanges • P4Z34 and assemblies fit 1/8" – 3/8" flanges and attach to #12 wire through 3/8" rod • P6Z34 fits 1/8" – 7/16" flanges and attaches to #12 wire through 3/8" rod with improved performance • No static load rating – for positioning only Image 2 Image 3 *Not UL or cUL listed. #10 – #12 Wire #8 – #9 Wire 3/16" – 1/4" Rod 1/8"– 1/4" Flange 1/2 EMT PK8 PK8 PK8 PK8 PK12 PK12 1/2 Rigid PK8 PK12 PK12 PK12 PK12 PK16 3/4 EMT PK12 PK12 PK12 PK12 PK16 PK16 3/4 Rigid PK12 PK12 PK16 PK16 PK20* PK20* 1 EMT ­– PK16 PK16 PK16 PK20* PK20* 1 Rigid ­– – – PK20* PK20* PK20* 1 1/4 EMT ­– PK20 PK20 PK20 – – Conduit Size (In.) 9/16"– 5/16"– 3/4" 1/2" Flange Flange *For horizontal applications only. Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P4Z34* 1 — — 100 P6Z34* 1 — — 100 P4Z348P 2 1/2 — 100 P4Z3412P 2 3/4 1/2 100 P4Z3416P 2 1 3/4 100 P4Z34812M 3 1/2 – 3/4 1/2 – 3/4 100 P4Z3416M 3 1 1 100 Part Number *UL and cUL listed. Note: May require dedicated drop wire/rod and PEC311 – consult local authority. H.9 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.10 Supports & Fasteners Cable/Conduit Conduit-To-Conduit Trapeze Assemblies with Snap-Close Clips ™ ™ StrongHold StrongHold Cable/Conduit Cable Tie Part Part Numbers Numbers One-Piece Strut Clamps • Designed to quickly secure one conduit run to another • No fasteners required • Static load capacity: Total trapeze must not exceed 100 lbs. Part Number Fits EMT/Rigid/IMC (In.) Std. Pkg Qty. 3/8* to 1 100 P166M P16812M 1/2 – 3/4 to 1 100 P1616M 1 to 1 100 P1620M 1 1/4 to 1 100 P1624M 1 1/2 to 1 100 *Or 14-2 through 12-3 MC/AC cable. Conduit-To-Conduit Trapeze Assemblies with Push-Fit Clips • Designed to quickly secure one conduit run to another • No fasteners required • Static load capacity: 25 Ibs. • Top conduit to be used for support only Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P8P8P 1/2 to 1/2 — 100 P8P12P 1/2 to 3/4 — 100 P8P16P 1/2 to 1 — 100 P12P12P 3/4 to 3/4 1/2 to 1/2 100 P12P16P 3/4 to 1 1/2 to 3/4 100 P16P16P 1 to 1 3/4 to 3/4 100 Part Number H.11 Order number of pieces required, in multiples of Standard Package Quantity. • Used to mount conduit to strut • All sizes available with load distribution saddle attached to screw to distribute weight • Suitable for use with standard 1 5/8" strut • Install with screwdriver, nut driver, or standard wrench Static Load Capacity (Lbs.) Std. Pkg. Qty. — — 100 — 50 100 3/4 1/2 50 50 PSCH16B 1 3/4 59 50 PSCH20B 1 1/4 1 75 50 PSCH24B 1 1/2 1 1/4 80 50 PSCH32B 2 1 1/2 100 25 PSCH40B — 2 80 25 PSCH48B 2 1/2 2 1/2 125 25 PSCH56B 3 3 160 10 PSCH64B 3 1/2 3 1/2 200 10 PSCH72B 4 4 330 10 Fits EMT (In.) Fits Rigid/IMC (In.) PSCH6B 3/8 PSCH8B 1/2 PSCH12B Part Number Call 866-405-6654 or visit www.panduit.com/stronghold H.12 Supports & Fasteners Cable/Conduit Universal Strut Clamps • Break-apart strut clamp • Install with screwdriver, nut driver, or standard wrench • Suitable for use with standard 1 5/8" strut • Material: mild steel ™ ™ StrongHold StrongHold Cable/Conduit Cable Tie Part Part Numbers Numbers Combination Box/Conduit Hangers from Drop Wire, Rod, and Beams • Secure 3/8" conduit (MC/AC cable) and 4" square boxes to most structures • Provide 3/8" conduit (MC/AC cable) support on both sides of electrical box • Available in a variety of mounting configurations Image 1 Fits EMT/Rigid/IMC (In.) Static Load Rating (Lbs.) Std. Pkg. Qty. PSK85I 1/2 200 100 PSK125I 3/4 200 100 PSK165I 1 200 100 PSK205I 1 1/4 200 100 PSK245I 1 1/2 200 50 PSK325I 2 200 50 PSK405I 2 1/2 350 50 PSK485I 3 350 50 PSK565I 3 1/2 350 25 PSK645I 4 350 25 Part Number Image 2 Image 3 Image 4 Fits EMT/ Rigid/IMC (In.) Std. Pkg. Qty. #12 wire through 1/4" flange 3/8* 25 2 Non-threaded center hole for screw or threaded rod mount 3/8* 25 P812MB18 1 #12 wire through 1/4" rod 1/2 – 3/4 25 P812MB18A 2 Non-threaded center hole for screw or threaded rod mount 1/2 – 3/4 25 P812MB1824 3 1/8" through 1/4" flange 1/2 – 3/4 25 Image No. Mounting Method P6MB18 1 P6MB18A Part Number *Or 14-2 through 12-3 MC/AC cable. H.13 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.14 Supports & Fasteners Cable/Conduit Combination Box/Conduit Hangers from Drop Wire, Rod, and Beams (continued) H.15 Mounting Method Fits EMT/ Rigid/IMC (In.) Std. Pkg. Qty. 1/2 – 3/4 25 Part Number Image No. P812MB18S 4 1/4-20 x 9/16" stud in center hole P16MB18 1 #12 wire through 1/4" rod 1 25 P16MB18A 2 Non-threaded center hole for screw or threaded rod mount 1 25 Order number of pieces required, in multiples of Standard Package Quantity. ™ ™ StrongHold StrongHold Cable/Conduit Cable Tie Part Part Numbers Numbers Flexible Conduit/Cable Clips • Suitable for flexible conduit and all types of cable • Support cable from 1/16" – 1/2" flange • No static load rating – for positioning only • Clip “snaps” on flange and cable “snaps” into clip Std. Pkg. Qty. AC/MC Cable O.D. (In.) Flange Size (In.) PSC2A 0.22 – 0.28 1/16 – 3/16 100 PSC2B 0.31 – 0.38 1/16 – 3/16 100 PSC2C 0.38 – 0.44 1/16 – 3/16 100 PSC2D 0.47 – 0.56 1/16 – 3/16 100 PSC2E 0.50 – 0.72 1/16 – 3/16 100 PSC2F 0.75 – 0.94 1/16 – 3/16 100 PSC2G 0.97 – 1.25 1/16 – 3/16 100 PSC4A 0.22 – 0.28 3/16 – 9/32 100 PSC4B 0.31 – 0.38 3/16 – 9/32 100 PSC4C 0.38 – 0.44 3/16 – 9/32 100 PSC4D 0.47 – 0.56 3/16 – 9/32 100 PSC4E 0.50 – 0.72 3/16 – 9/32 100 PSC4F 0.75 – 0.94 3/16 – 9/32 100 PSC4G 0.97 – 1.25 3/16 – 9/32 100 PSC8A 0.22 – 0.28 5/16 – 1/2 100 PSC8B 0.31 – 0.38 5/16 – 1/2 100 PSC8C 0.38 – 0.44 5/16 – 1/2 100 PSC8D 0.47 – 0.56 5/16 – 1/2 100 PSC8E 0.50 – 0.72 5/16 – 1/2 100 PSC8F 0.75 – 0.94 5/16 – 1/2 100 PSC8G 0.97 – 1.25 5/16 – 1/2 100 Part Number Call 866-405-6654 or visit www.panduit.com/stronghold H.16 Supports & Fasteners Cable/Conduit Flexible Cable Clip Part Number P449 • Properly space and support MC/AC cable • Prevent derating of electrical cable • Comply with NEC Article 310.15 (reference pages O.4 – O.5 for details) Std. Pkg. Qty. 12-2 (0.47 – 0.51 O.D.) 12-3 (0.49 – 0.54 O.D.) 14-2 (0.43 – 0.48 O.D.) 14-3 (0.46 – 0.50 O.D.) Mount with self-tapping screws found on page H.49! Support Brackets for MC/AC Cable • Push clip to attach MC or AC cable to metal stud • No tools required for installation • Provides fast installation Cable Size (In.) StrongHold ™ Cable/Conduit Part Numbers Image 1 100 Image 2 Part Number Flexible Conduit/Cable Hangers • Bundle runs of MC and AC cable • Can be used with variety of mounting hardware • Easy to close without the use of tools Part Number H.17 Description Ultimate Load (Lbs.) Std. Pkg. Qty. PWMX3 Cable hanger for 1 1/8" diameter bundle – 3 runs of MC/AC. 50 100 PWMX6 Cable hanger for 1 3/4" diameter bundle – 6 runs of MC/AC. 75 100 Order number of pieces required, in multiples of Standard Package Quantity. Image No. Capacity Std. Pkg. Qty. PMCS50 1 Up to 4 runs of MC/AC cable 0.43" – 0.56" in diameter 100 PMCS100 2 Up to 8 runs of MC/AC cable 0.43" – 0.56" in diameter 50 PMCS101 2 Up to 7 runs of MC/AC cable 0.56" – 0.69" in diameter 50 Call 866-405-6654 or visit www.panduit.com/stronghold H.18 Supports & Fasteners Supports & Fasteners Cable/Conduit Nail/Conduit Brackets Image 1 Beam/Purlin Screw-On Beam Clamps • Attach to beam with screw • Install with screwdriver, nut driver, or standard wrench • Incorporate tapped holes to accommodate threaded rod • Attach conduit to wood, steel, and concrete • Eliminate offset bends on 1 1/2" box • No static load rating – for positioning only • May be attached after positioning conduit PBC PBC200 Image 2 Part Number Image No. PCNB812M 1 Fits EMT (In.) 1/2 – 3/4 Fits Rigid/IMC (In.) Part Number Flange Thickness (In.) 1/2 – 3/4 100 PBC* Up to 1/2 1/4-20 in back and bottom; #10-24 in back 100 Spring Steel 100 PBC200 Up to 1/2 1/4-20 in back and bottom 100 Zinc Plated Steel 50 Up to 15/16 3/8-16 in back and bottom 200 Zinc Plated Steel 25 PCNB8P 2 1/2 — 100 2 3/4 1/2 100 PBC400** Metal Deck/Conduit Brackets • Provide spacing between conduit and deck surface • Eliminate offset bends on 2 1/8" box • No static load rating – for positioning only • May be attached after positioning conduit Part Number H.19 Static Load Rating (Lbs.) Std. Pkg. Qty. PCNB12P Fits EMT (In.) PBC400 Fits Rigid/IMC (In.) Std. Pkg. Qty. PAOL8P 1/2 — 100 PAOL12P 3/4 1/2 100 PAOL16P 1 3/4 100 Order number of pieces required, in multiples of Standard Package Quantity. Tapped Hole Material Std. Pkg. Qty. *3/8" non-threaded clearance hole in top and bottom; 1/4" non-threaded clearance hole in back. **UL and cUL listed. Call 866-405-6654 or visit www.panduit.com/stronghold H.20 Supports & Fasteners Beam/Purlin Hammer-On Beam Clamps Hammer-On Beam Clamps with Attachment Tab • Hammer-on installation • Attachment tab provides 1/4" clearance hole for wire, S-hooks, or chain assemblies • Static load capacity: 200 lbs. Image 1 Flange Thickness (In.) Std. Pkg. Qty. P4H24 1/8 – 1/4 100 P4H58 5/16 – 1/2 100 P4H912 9/16 – 3/4 100 Part Number H.21 StrongHold ™ Beam/Purlin Part Numbers Order number of pieces required, in multiples of Standard Package Quantity. • Hammer-on installation • Provided with a 1/4-20 thread so that boxes, fixtures, and bridle rings may be quickly and securely attached to the beam flanges (Image 1) • Also available with 1/4-20 x 3/8" staked stud for easier attachment of outlet boxes to beams; eliminates need to use additional screws (Image 2) • Static load capacity: 75 lbs. Image 2 Part Number Image No. Flange Thickness (In.) Std. Pkg. Qty. PM24 1 1/8 – 1/4 100 PM58 1 5/16 – 1/2 100 PM912 1 9/16 – 3/4 100 PM24S 2 1/8 – 1/4 100 PM58S 2 5/16 – 1/2 100 PM912S 2 9/16 – 3/4 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.22 Supports & Fasteners Beam/Purlin Reversible Beam Clamps Image 1 Spring Steel Screw-On Beam Clamp Assemblies • Easily attach conduit to beams • Can be installed on flange up to 1/2" thick • Include snap-close or push-fit conduit fittings • Used when drop-rod length must be adjusted to accommodate a finished height in the field • Jam nut included to prevent vibratory loosening • Manufactured from malleable iron Image 1 Image 2 Image 2 Image 3 Image No. Flange Thickness (In.) Threaded Hole Std. Pkg. Qty. P3000037EG 1 3/4 3/8-16 25 P3000050EG 1 3/4 1/2-13 25 P3100037EG 2 1 1/4 3/8-16 25 PBC260025EG 3 1 1/4 1/4-20 50 Part Number H.23 StrongHold ™ Beam/Purlin Part Numbers Order number of pieces required, in multiples of Standard Package Quantity. Image 3 Image 4 Fits Rigid/IMC (In.) Static Load Rating (Lbs.) Std. Pkg. Qty. Part Number Image No. Fits EMT (In.) PBC8P 1 1/2 — 25 100 PBC12P 1 3/4 1/2 25 100 PBC16P 1 1 3/4 25 100 PBC8PSM 2 1/2 — 15 100 PBC12PSM 2 3/4 1/2 15 100 PBC16PSM 2 1 3/4 15 100 PBC812M 3 1/2 – 3/4 1/2 – 3/4 100 100 PBC16M 3 1 1 100 100 PBC20M 3 1 1/4 1 1/4 100 100 PBC24M 3 1 1/2 1 1/2 100 100 PBC32M 3 2 2 100 100 PBC812MSM 4 1/2 – 3/4 1/2 – 3/4 25 100 PBC16MSM 4 1 1 25 100 PBC20MSM 4 1 1/4 1 1/4 25 100 PBC24MSM 4 1 1/2 1 1/2 25 100 PBC32MSM 4 2 2 25 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.24 Supports & Fasteners Beam/Purlin Screw-On Beam Clamp Assemblies with Conduit Clamps StrongHold ™ Beam/Purlin Part Numbers Hammer-On Beam Clamps with Rod Hanger • Easily attach conduit to beams up to 1/2" thick • Conduit clamps provide positive securing feature • Suitable for EMT or Rigid/IMC conduit Image 1 Part Number Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. PBC200CD1B 3/4 3/4 100 PBC200CD2B 1 1 100 PBC200CD2.5B 1 1/4 — 100 PBC200CD3B 1 1/2 1 1/4 100 PBC200CD4B — 1 1/2 50 PBC200CD5B 2 2 50 • Hammer-on beam clamps allow for easy installation • Options available for threaded or non-threaded rod • Options available for flanges 1/8" – 3/4" thick • Static load capacity: 160 lbs. Image 2 Image 3 Image 4 Flange Thickness (In.) Rod Size Std. Pkg. Qty. 1 1/8 – 1/4 1/4-20 threaded 100 1 5/16 – 1/2 1/4-20 threaded 100 P4TI912 1 9/16 – 3/4 1/4-20 threaded 100 P6TI24 1 1/8 – 1/4 3/8-16 threaded 100 P6TI58 1 5/16 – 1/2 3/8-16 threaded 100 P6TI912 1 9/16 – 3/4 3/8-16 threaded 100 P6TA24* 2 1/8 – 1/4 1/4" – 3/8"; requires nuts 100 P6TA58* 2 5/16 – 1/2 1/4" – 3/8"; requires nuts 100 P6A24 3 1/8 – 1/4 3/8" non-threaded 100 P6A58 3 5/16 – 1/2 3/8" non-threaded 100 P6A912 3 9/16 – 3/4 3/8" non-threaded 100 P70824 4 1/8 – 1/4 8 wire or 1/4" plain rod 100 P70858 4 5/16 – 1/2 8 wire or 1/4" plain rod 100 P708912 4 9/16 – 3/4 8 wire or 1/4" plain rod 100 Part Number Image No. P4TI24 P4TI58 *UL and cUL listed. H.25 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.26 Supports & Fasteners Beam/Purlin Purlin Clips – Spring Steel PVF14 StrongHold ™ Beam/Purlin Part Numbers Z-Purlin Clips • Fasteners fit flanges 1/16" – 1/4" thick • Support wire and assemblies from vertical or angled flanges • Hammer-on installation • Material: spring steel • Static load capacity: 100 lbs. • Provide a method for attaching conduit and boxes to angled flanges • Installed by hand without the use of power tools • Static load capacity: 100 lbs. P122 PAF14 P123 Part Number Flange Orientation Std. Pkg. Qty. Part Number PVF14 Vertical 100 P122 100 PAF14 Angled 100 1/4" hole for wire, S-hooks, and jack chain. P123 1/4" hole in bottom for assemblies. 100 H.27 Order number of pieces required, in multiples of Standard Package Quantity. Description Call 866-405-6654 or visit www.panduit.com/stronghold Std. Pkg. Qty. H.28 Supports & Fasteners Beam/Purlin Purlin Clip Assemblies for Threaded Rod and Drop Wire Applications Image 1 Z-Purlin Clip Assemblies for Conduit Applications • Provide a method for attaching conduit to angled flanges • Installed by hand without the use of power tools • Suspend threaded rod and drop wire from vertical flange • Hammer-on installation • Material: spring steel • Static load capacity: 160 lbs. • Flange thickness: 1/16" – 5/32" Image 1 Image 2 Image 2 Image No. Rod Size Std. Pkg. Qty. PVF144TI 1 1/4-20 threaded PVF146TI 1 3/8-16 threaded Part Number PVF146T PVF14708 StrongHold ™ Beam/Purlin Part Numbers 1 2 1/4" – 3/8" requires nuts #8 wire or 1/4" plain rod Fits Rigid/IMC (In.) Static Load Rating (Lbs.) Std. Pkg. Qty. 100 Part Number Image No. Fits EMT (In.) 100 P1238P 1 1/2 — 25 100 100 P12312P 1 3/4 1/2 25 100 100 P12316P 1 1 3/4 25 100 P1236M 2 3/8 3/8 100 100 P123812M 2 1/2 – 3/4 1/2 – 3/4 100 100 P12316M* 2 1 1 100 100 P12320M 2 1 1/4 1 1/4 100 100 *UL and cUL listed. H.29 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.30 Supports & Fasteners Supports & Fasteners Beam/Purlin Hangers/Hanging Systems Rod and Wire Hangers with Bracket Supports Z-Purlin Clip Assemblies for Threaded Rod and Drop Wire Applications • Provide a method for attaching conduit and boxes to angled flanges • Installed by hand without the use of power tools • Static load capacity: 100 lbs. Image 1 • Suspend #8 wire, 1/4", and 3/8" non-threaded or threaded rod from overhead mountings • 1/4" clearance hole in right angle and offset brackets • Static load capacity: 160 lbs. Image 1 Image 3 Image 4 Image 5 Image 6 Image 7 Image 3 Image 2 Part Number Image No. Rod Size Std. Pkg. Qty. P1224TI 1 1/4-20 threaded 100 P1226TI 1 3/8-16 threaded 100 P1226T 2 1/4" – 3/8" threaded; requires nuts 100 P122708 3 #8 wire or 1/4" plain rod 100 H.31 Image 2 Order number of pieces required, in multiples of Standard Package Quantity. Part Number P4TIB Image No. 1 Rod Size 1/4-20 threaded rod Bracket Orientation Std. Pkg. Qty. Right Angle 100 P6TIB 1 3/8-16 threaded rod Right Angle 100 P6TB 2 1/4" – 3/8" threaded rod; requires nut Right Angle 100 P6AO 3 3/8 non-threaded rod Offset 100 P4TIO 4 1/4-20 threaded rod Offset 100 P6TIO 4 3/8-16 threaded rod Offset 100 P6TO 5 1/4" – 3/8" threaded rod; requires nut Offset 100 P708AB 6 #8 wire or 1/4" plain rod Right Angle 100 P708AO 7 #8 wire or 1/4" plain rod Offset 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.32 Supports & Fasteners Supports & Fasteners Hangers/Hanging Systems Strap Hangers Stud Wall Electrical Box Mounting Support Brackets • Support pipe or duct from flange with banding or strapping up to 1" wide • Options available for beams 1/8" – 3/4" thick • Hammer-on installation • Static load capacity: 200 lbs. Image 1 Image 1 Mount with self-tapping screws found on page H.49! • Attach 4" or 4 11/16" electrical outlet boxes to studs • Support feature reduces box movement in wall • Manufactured from pre-galvanized steel • Comply with NEC Article 300.4 (D) (reference pages O.1 for details) Image 2 Part Number Image No. Flange Thickness (In.) Std. Pkg. Qty. PMSS24 1 1/8 – 1/4 100 PMSS58 1 5/16 – 1/2 100 PMSS912 1 9/16 – 3/4 100 PMSR24 2 1/8 – 1/4 100 PMSR58 2 5/16 – 1/2 100 PMSR912 2 9/16 – 3/4 100 H.33 Order number of pieces required, in multiples of Standard Package Quantity. Image 2 Part Number Image No. Stud Depth (In.) Std. Pkg. Qty. PH23 1 2 1/2 and 3 1/2 100 PH4 1 2 1/2, 3 1/2, and 4 100 PH6 1 6 100 PMEB1 2 2 1/2, 3 1/2, and 4 25 Call 866-405-6654 or visit www.panduit.com/stronghold H.34 Supports & Fasteners Stud Wall Mount with self-tapping screws found on page H.49! Screw-On Conduit Supports StrongHold ™ Stud Wall Part Numbers • Comply with NEC Article 358.30 to support conduit close to electrical box • Accommodate EMT and MC/AC cable • Allow conduit to align with box knockouts when used with PH series brackets (see page H.1) • Secure electrical boxes to most metal studs • Include 1/4" hole to secure to stud with user-supplied screw • Hammer-on installation PMSF Fits EMT (In.) Electrical Box Depth Color Std. Pkg. Qty. PCS16* 1 2 1/8 Black 100 PCS812 1/2 – 3/4 1 1/2 Black 100 PCS812D 1/2 – 3/4 2 1/8 Silver 100 Part Number Mount with self-tapping screws found on page H.49! Hammer-On Box to Stud Supports *Not UL or cUL listed. PMFS Part Number PMFO Description Std. Pkg. Qty. PMSF Box to stud support – non-adjustable. 100 PMFS Box to stud support with screw, adjustable for 1/4" – 3/4" dry wall. 100 PMFO Box to stud support flush to stud face – preset. 100 Press-On Nail Plate • Fast installation; no tools required • Protects electrical, datacom, and plumbing infrastructure • Meets NEC Article 300.4 requirements (reference pages O.1 for details) Part Number P304B2 H.35 Description Press-on nail plate for wood or metal studs. Std. Pkg. Qty. 100 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.36 Supports & Fasteners Stud Wall Switch Box to Metal Stud Brackets Mount with self-tapping screws found on page H.49! StrongHold ™ Stud Wall Part Numbers • Designed to quickly install conduit to metal studs • Available in push-fit (Image 1) or snap-close (Image 2) fittings • Suitable for both EMT and Rigid/IMC conduit • Secure electrical boxes to most metal studs • Preset versions offset for specific dry wall thickness • Include 1/4" hole to secure to stud with user-supplied screw • Hammer-on installation Part Number Dry Wall Thickness (In.) Image 1 Std. Pkg. Qty. PMF250 1/4 100 PMF375 3/8 100 PMF500 1/2 100 PMF625 5/8 100 PMF750 3/4 100 Image 2 Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P8PF 1 1/2 — 100 P12PF 1 3/4 1/2 100 P16PF 1 1 3/4 100 P6MF 2 3/8 3/8 100 P812MF 2 1/2 – 3/4 1/2 – 3/4 100 P16MF 2 1 1 100 Part Number H.37 Mount with self-tapping screws found on page H.49! Hammer-On Conduit to Metal Stud Brackets Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.38 Supports & Fasteners Cable Ties Stud Wall Mount with self-tapping screws found on page H.49! Screw-On Box to Stud Support StrongHold ™ Stud Wall Part Numbers Far-Side Box Supports • Installs to stud with user-supplied screws • For use with metal or wood studs • Used independently or with assemblies for electrical box or conduit support Part Number Std. Pkg. Qty. Description P350 Image 1 • Clip to electrical box to utilize dry wall on far side of box for support • Used with 1 1/2" or 2 1/8" deep electrical box • Prevent electrical box from recessing into wall cavity • No static load rating – for positioning only Screw-mounted box to stud support. 100 Image 2 Image 3 Screw-On Conduit to Stud Supports Mount with self-tapping screws found on page H.49! Image No. Figure No. Stud Depth (In.) Std. Pkg. Qty. PJ1A25 1 1 2 1/2 100 PJ1A35 1 1 3 1/2 100 PJ1A4 1 1 4 100 PJ1A6 1 1 6 100 P766 2 1 2 1/2 – 4 100 P766PMD 3 2 3 5/8 100 Part Number • Designed to install runs of conduit to metal studs • Suitable for EMT and Rigid/IMC conduit • Available in push-fit (Image 1) or snap-close (Image 2) fittings Image 1 Image 2 Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P3508P 1 1/2 — 100 P35012P 1 3/4 1/2 100 P35016P 1 1 3/4 100 P350812M 2 1/2 – 3/4 1/2 – 3/4 100 P35016M 2 1 1 100 Part Number Mud ring Cut off here for deep box applications H.39 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.40 Supports & Fasteners Stud Wall Adjustable Screw Gun Box Mounting Brackets Mount with self-tapping screws found on page H.49! Rigid Box Mounting Brackets Description Mount with self-tapping screws found on page H.49! • Used to secure multiple electrical boxes in stud walls • Mount 1 1/2" or 2 1/8" deep electrical boxes • Suitable for 4" or 4 11/16" wide electrical boxes • Adjustable to allow variability between stud spacing • Utilized to mount electrical box between studs • Suitable for 1 1/2" or 2 1/8" deep electrical boxes Part Number StrongHold ™ Stud Wall Part Numbers PRBS16 Std. Pkg. Qty. PTSGB16 Mount box between studs spaced 11" – 18". 50 PTSGB24 Mount box between studs spaced 17" – 26". 50 PRBS24 Part Number Description Std. Pkg. Qty. PRBS16 Rigid box mounting bracket for 16" stud spacing; capacity of three electrical boxes. 50 PRBS24* Rigid box mounting bracket for 24" stud spacing; capacity of four electrical boxes. 25 *Not UL or cUL listed. H.41 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.42 Supports & Fasteners Stud Wall Floor-Mounted Box Bracket Mount with self-tapping screws found on page H.49! StrongHold ™ Stud Wall Part Numbers • Supports electrical box at consistent spacing from floor level • Features can be used to prevent electrical box from being pushed into wall cavity • Mounts 4" or 4 11/16" wide electrical boxes; 1 1/2" or 2 1/8" deep • Meets ADA (Americans with Disabilities Act) accessibility guidelines/standards Part Number PFMBS18 Description Floor-mounted box bracket to mount center of electrical box 18" off floor. Std. Pkg. Qty. • Used to maintain appropriate cable spacing behind dry wall to comply with NEC Article 300.4 (D) (reference pages O.1 – O.2 for details) • Attaches to wood or metal stud with user-supplied screws • Accommodates a variety of cable types Part Number PCJ6 25 Cable Type H.43 Mount with self-tapping screws found on page H.49! Cable Support Clip Order number of pieces required, in multiples of Standard Package Quantity. Std. Pkg. Qty. Description Cable support clip to provide 1 1/2" spacing for cables behind dry wall. Cables Per Clip 100 Cable Size Non-metallic 6 14-2, 12-2, 10-2, 14-3, 12-3, 10-3 with ground Non-metallic 4 8-2, 6-2 with ground MC/AC 4 14-2, 12-2, 10-2, 14-3, 12-3, 10-3, 14-4, 12-4, 10-4 with ground Call 866-405-6654 or visit www.panduit.com/stronghold H.44 Supports & Fasteners Stud Wall Anti-Rattle Bracket Mount with self-tapping screws found on page H.49! StrongHold ™ Stud Wall Part Numbers Cable Support Clip for Single Cable • Used as noise reduction and to stop rattling from Conduit, BX Cable, Armored Cable (EMT, MC/AC), or Rigid Conduit, when pulled through metal studs • Attaches to metal stud with user supplied self-tapping screws • Accommodates a variety of cable types up to 1" in diameter • Meets ADA (Americans with Disabilities Act) accessibility guidelines/standards Part Number SH781 H.45 Description Anti-rattle bracket for support of armored cable and conduit up to 1" in diameter, through metal stud wall. Std. Pkg. Qty. Mount with self-tapping screws found on page H.49! • Used to maintain appropriate cable spacing behind dry wall to comply with NEC Article 300.4 (D) (reference pages O.1 – O.2 for details) • Provides 1 1/2" spacing for cables behind dry wall • Attaches to wood or metal studs with hammer Part Number PFXC20 Description Std. Pkg. Qty. Accommodates MC/AC cable (12-2 through 10-3). 100 100 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.46 Supports & Fasteners Stud Wall Mount with self-tapping screws found on page H.49! Through-Stud Conduit Supports StrongHold ™ Stud Wall Part Numbers Metal Stud Grommets • Install in pre-punched hole in metal studs • Protect cable within the building structure • Utilize metal stud punch tool (see page H.18) to create suitable holes in specific locations • Designed to secure horizontal runs of conduit through metal studs • Eliminate rattling conduit • Available with push-fit (Image 1) or snap-close (Image 2) conduit fittings MSG-1.3-C Image 1 MSGV-1.3-C Image 2 Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. PFB8P 1 1/2 — 100 PFB12P 1 3/4 1/2 100 PFB6M 2 3/8 3/8 100 PFB812M 2 1/2 – 3/4 1/2 – 3/4 100 Part Number H.47 Order number of pieces required, in multiples of Standard Package Quantity. Part Number Description Std. Pkg. Qty. MSG-1.3-C Metal stud grommet. 100 MSGV-1.3-C Metal stud grommet, anti-vibration tabs for 1/2" – 1" pipe. 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.48 Supports & Fasteners Stud Wall Cable Manager StrongHold ™ Stud Wall Part Numbers Metal Stud Punch Tool • Installs in pre-punched hole in metal studs • Protects cable within the building structure • Utilizes metal stud punch tool (see page H.18) to create suitable holes in specific locations Part Number CSM-1.25-C Description Cable stud manager for 1 1/4" cable spacing. • Punches 1 11/32" round hole in 25 gauge minimum to 20 gauge maximum mild steel studs • Contoured handle allows for increased leverage • Automatic hole centering on standard width (3 5/8") studs • Replaceable punch and dies • Self-stripping design that eliminates punch malfunctions Std. Pkg. Qty. 100 Part Number MSPT-1.3 Std. Pkg. Qty. Description Metal stud punch tool. 1 Self-Tapping Screw • Used to secure StrongHold™ components to metal studs • Low profile head utilizes #2 phillips head • Packaging: plastic job jar Part Number PSMS8 H.49 Order number of pieces required, in multiples of Standard Package Quantity. Description 8 x 1/2" low profile self-tapping screw. Std. Pkg. Qty. 1000 Call 866-405-6654 or visit www.panduit.com/stronghold H.50 Supports & Fasteners Communications/ Low Voltage StrongHold™ Communications/Low Voltage Part Numbers J-Pro™ Series Referenced Images J-Pro™ JP75 Series • UL listed for use in plenum or air handling spaces (such as ceiling voids and underfloor areas) per NEC Article 300.22 (C) and (D) (reference pages O.2 – O.4 for details) • Complete horizontal and vertical 1" bend radius control • Bundle capacity: 3/4" • Cable capacity: Category 6A (5), Category 6A (SD) (8), Category 6 (8), Category 5e (10) Image 1 Image 4 Image 7 Image 10 Image 2 Image 5 Image 8 Image 11 Image 3 Image 6 Image 9 Std. Pkg. Qty. Part Number Image No. JP75W-L20 1 Wall mount – one 1/4" mounting hole. 50 JP75WP2B-L20 2 Wall mount for powder actuated fasteners – one 5/32" and one 1/4" mounting hole. 50 JP75CMB-L20 3 Ceiling mount – 3/16", 1/4", and 3/8" mounting holes. 50 JP75DW-L20 4 Drop wire and threaded rod clip mount. 50 JP75SBC50-L20 5 Screw-on beam clamp mount – up to 1/2" flange. 50 JP75SBC50RB-L20 6 Screw-on beam clamp mount – up to 1/2" flange. Rotates 360°. 50 JP75SBC87-L20 7 Screw-on beam clamp mount – up to 3/4" flange. 50 JP75SBC87RB-L20 8 Screw-on beam clamp mount – up to 3/4" flange. Rotates 360°. 50 JP75HBC25RB-L20 9 Hammer-on beam clamp mount – 1/8" - 1/4" flange. Rotates 360°. 50 JP75HBC50RB-L20 9 Hammer-on beam clamp mount – 5/16" – 1/2" flange. Rotates 360°. 50 JP75HBC75RB-L20 9 Hammer-on beam clamp mount – 9/16" – 3/4" flange. Rotates 360°. 50 JP75CP-L20 10 C-purlin clips for straight flanges up to 1/4" thick. 50 JP75ZP-L20 11 Z-purlin clips for angled flanges up to 1/4" thick. 50 JP75UF100-L20 12 Underfloor pedestal support clip for pedestal 7/8" square or 1 1/8" – 1 3/8" in diameter. 50 Description Image 12 Available colors can be found on page H.57 H.51 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.52 Supports & Fasteners Communications/ Low Voltage StrongHold™ Communications/Low Voltage Part Numbers J-Pro™ JP131 Series J-Pro™ JP2 Series • Bundle capacity: 1 5/6" • Cable capacity: Category 6A (15), Category 6A (SD) (25), Category 6 (25), Category 5e (29) • Bundle capacity: 2" • Cable capacity: Category 6A (30), Category 6A (SD) (46), Category 6 (46), Category 5e (55) Part Number JP131W-L20 Image No. 1 Std. Pkg. Qty. Wall mount – one 1/4" mounting hole. 50 Description JP131WP2B-L20 2 Wall mount for powder actuated fasteners – one 5/32" and one 1/4" mounting hole. 50 JP131CMB-L20 3 Ceiling mount – 3/16", 1/4", and 3/8" mounting holes. 50 JP131DW-L20 4 Drop wire and threaded rod clip mount. 50 JP131SBC50-L20 5 Screw-on beam clamp mount – up to 1/2" flange. 50 JP131SBC50RBL20 6 Screw-on beam clamp mount – up to 1/2" flange. Rotates 360°. 50 JP131SBC87-L20 7 Screw-on beam clamp mount – up to 3/4" flange. 50 JP131SBC87RBL20 8 Screw-on beam clamp mount – up to 3/4" flange. Rotates 360°. 50 JP131HBC25RBL20 9 Hammer-on beam clamp mount – 1/8" – 1/4" flange. Rotates 360°. 50 JP131HBC50RBL20 9 Hammer-on beam clamp mount – 5/16" – 1/2" flange. Rotates 360°. 50 JP131HBC75RBL20 9 Hammer-on beam clamp mount – 9/16" – 3/4" flange. Rotates 360°. 50 JP131CP-L20 10 C-purlin clips for straight flanges up to 1/4" thick. 50 JP131ZP-L20 11 Z-purlin clips for angled flanges up to 1/4" thick. 50 JP131UF100-L20 12 Underfloor pedestal support clip for pedestal 7/8" square or 1 1/8" – 1 3/8" in diameter. 50 H.53 Order number of pieces required, in multiples of Standard Package Quantity. Part Number Image No. Description Std. Pkg. Qty. JP2W-L20 1 Wall mount – one 1/4" mounting hole. 50 JP2WP2B-L20 2 Wall mount for powder actuated fasteners – one 5/32" and one 1/4" mounting hole. 50 JP2CMB-L20 3 Ceiling mount – 3/16", 1/4", and 3/8" mounting holes. 50 JP2DW-L20 4 Drop wire and threaded rod clip mount. 50 JP2SBC50-L20 5 Screw-on beam clamp mount – up to 1/2" flange. 50 JP2SBC50RB-L20 6 Screw-on beam clamp mount – up to 1/2" flange. Rotates 360°. 50 JP2SBC87-L20 7 Screw-on beam clamp mount – up to 3/4" flange. 50 JP2SBC87RB-L20 8 Screw-on beam clamp mount – up to 3/4" flange. Rotates 360°. 50 JP2HBC25RB-L20 9 Hammer-on beam clamp mount – 1/8" – 1/4" flange. Rotates 360°. 50 JP2HBC50RB-L20 9 Hammer-on beam clamp mount – 5/16" – 1/2" flange. Rotates 360°. 50 JP2HBC75RB-L20 9 Hammer-on beam clamp mount – 9/16" – 3/4" flange. Rotates 360°. 50 JP2CP-L20 10 C-purlin clips for straight flanges up to 1/4" thick. 50 JP2ZP-L20 11 Z-purlin clips for angled flanges up to 1/4" thick. 50 JP2UF100-L20 12 Underfloor pedestal support clip for pedestal 7/8" square or 1 1/8" –1 3/8" in diameter. 50 Call 866-405-6654 or visit www.panduit.com/stronghold H.54 Supports & Fasteners Communications/ Low Voltage J-Pro™ JP4 Series StrongHold™ Communications/Low Voltage Part Numbers J-Pro™ Extension Bracket • Bundle capacity: 4" • Cable capacity: Category 6A (115), Category 6A (SD) (180), Category 6 (180), Category 5e (200) Part Number Image No. Description Std. Pkg. Qty. JP4W-X20 1 Wall mount – one 1/4" mounting hole. 10 JP4WP2B-X20 2 Wall mount for powder actuated fasteners – one 5/32" and one 1/4" mounting hole. 10 • Compatible with 3/4", 1 5/16", and 2" J-Pro™ products • Allows multiple hooks to be installed utilizing one attachment point • Includes 1/8", 1/4", and 3/8" mounting holes for various user-supplied hardware Part Number PCATHBA JP4CMB-X20 3 Ceiling mount – 3/16", 1/4", and 3/8" mounting holes. 10 JP4SBC50-X20 5 Screw-on beam clamp mount – up to 1/2" flange. 10 JP4SBC50RB-X20 6 Screw-on beam clamp mount – up to 1/2" flange. Rotates 360°. 10 JP4SBC87-X20 7 Screw-on beam clamp mount – up to 3/4" flange. 10 JP4SBC87RB-X20 8 Screw-on beam clamp mount – up to 3/4" flange. Rotates 360°. 10 JP4HBC25RB-X20 9 Hammer-on beam clamp mount – 1/8" – 1/4" flange. Rotates 360°. 10 JP4HBC50RB-X20 9 Hammer-on beam clamp mount – 5/16" – 1/2" flange. Rotates 360°. 10 JP4HBC75RB-X20 9 Hammer-on beam clamp mount – 9/16" – 3/4" flange. Rotates 360°. 10 JP4CP-X20 10 C-purlin clips for straight flanges up to 1/4" thick. 10 JP4ZP-X20 11 Z-purlin clips for angled flanges up to 1/4" thick. 10 JP4UF100-X20 12 Underfloor pedestal support clip for pedestal 7/8" square or 1 1/8" – 1 3/8" in diameter. 10 Description Multi-tier bracket for J-Pro™ product line. Bend appropriate tabs with flathead screwdriver to prevent intended hook from rotating once installed. Order number of pieces required, in multiples of Standard Package Quantity. 10 Install appropriate J-Pro™ wall-mounted hook with user-supplied hardware. To mount additional hooks to the same bracket, bend the appropriate tabs with flathead screwdriver to prevent hook from rotating once installed. H.55 Std. Pkg. Qty. Install additional J-Pro™ wall-mounted hook with user-supplied hardware. Call 866-405-6654 or visit www.panduit.com/stronghold H.56 Supports & Fasteners Communications/ Low Voltage J-Pro™ Color Selection Guide StrongHold™ Communications/Low Voltage Part Numbers J-Pro™ Color Selection Guide (continued) Base Part Number Black Red JP75W -L20 -L2 JP75WP2B -L20 JP75CMB -L20 -L2 JP75DW -L20 -L2 JP75ZP JP75CP Blue White Green Orange -L5 -L3 Base Part Number Black JP2HBC75RB -L20 JP2UF100 -L20 JP4W -X20 JP4WP2B -X20 -L20 JP4CMB -X20 -L20 JP4ZP -X20 JP75SBC50 -L20 JP4CP -X20 JP75SBC87 -L20 JP4SBC50 -X20 JP75SBC50RB -L20 JP4SBC87 -X20 JP75SBC87RB -L20 JP4SBC50RB -X20 JP75HBC25RB -L20 JP75HBC50RB -L20 JP4SBC87RB -X20 JP75HBC75RB -L20 JP4HBC25RB -X20 JP75UF100 -L20 JP4HBC50RB -X20 JP131W -L20 JP4HBC75RB -X20 JP131WP2B -L20 JP4UF100 -X20 JP131CMB -L20 JP131DW -L20 JP131ZP -L20 JP131CP -L20 JP131SBC50 -L20 JP131SBC87 -L20 JP131SBC50RB -L20 JP131SBC87RB -L20 JP131HBC25RB -L20 JP131HBC50RB -L20 JP131HBC75RB -L20 JP131UF100 -L20 JP2W -L20 JP2WP2B -L20 -L2 -L -L6 -L5 -L3 -L5 -L3 Blue White -X2 -X6 -X Green Orange -X -X2 -X -X2 -X -L6 -L2 -L -L2 -L -L2 JP2CMB -L20 -L2 -L20 -L2 JP2ZP -L20 JP2CP -L20 JP2SBC50 -L20 JP2SBC87 -L20 JP2SBC50RB -L20 -L2 JP2SBC87RB -L20 -L2 JP2HBC25RB -L20 H.57 -L -L2 JP2DW JP2HBC50RB -L20 Table continues on page H.57 -L6 Red -L6 -L -L6 -L -L -L2 -L -L Order number of pieces required, in multiples of Standard Package Quantity. Additional colors available, contact your local sales representative or go to www.panduit.com for availability. Call 866-405-6654 or visit www.panduit.com/stronghold H.58 Supports & Fasteners Communications/ Low Voltage StrongHold™ Communications/Low Voltage Part Numbers J-Mod® Series Installation Instructions J-Mod® Series Referenced Images • UL listed for use in plenum or air handling spaces (such as ceiling voids and underfloor areas) per NEC Article 300.22 (C) and (D) (reference pages O.2 – O.4 for details) • Complete horizontal and vertical 1" bend radius control Image 1 H.59 Image 2 Image 3 Image 4 Image 5 Image 6 Image 7 Image 8 Image 9 Image 10 Image 11 Order number of pieces required, in multiples of Standard Package Quantity. Align snap lock Align chaining bracket attachment of J-hook under the assembly. with holes in chosen bracket and snap J-hook into place. Pull down to fully engage. Slide chaining bracket between J-hook and the metal bracket until it snaps. Attach J-hooks as Final assembly explained in first-level is a second-level installation above. installation consisting of one threaded rod bracket, one chaining bracket, and two J-hooks for clarity. Call 866-405-6654 or visit www.panduit.com/stronghold H.60 Supports & Fasteners Communications/ Low Voltage J-Mod® Series StrongHold™ Communications/Low Voltage Part Numbers Hook and Loop Cable Ties • Bundle capacity: 2" • Cable capacity: Category 6A (30), Category 6A (SD) (46), Category 6 (46), Category 5e (55) Part Number JMJH2W-X20 Image No. 1 Description Std. Pkg. Qty. J-hook for wall mount applications only; two 1/4" mounting holes for user supplied screws. 10 JMJH2-X20 2 J-hook for use with J-Mod® brackets. 10 JMCB-X 3 Chaining bracket to extend existing J-Mod® capacity; for use with single-level mounting brackets; three levels maximum. 10 JMCMB25-1-X 4 Single-level ceiling mount bracket with one 1/4" mounting hole. 10 JMCMB25-3-X 5 Three-level ceiling mount bracket with one 1/4" mounting hole. 10 JMDWB-1-X 6 Single-level drop wire bracket that attaches to #12 wire or 1/4" threaded rod. 10 Image 1 • Soft, premium material is safe for use on high-performance communication cable • UL listed for use in plenum or air handling spaces (such as ceiling voids and underfloor areas) per NEC Article 300.22 (C) and (D) (reference pages O.2 – O.4 for details) • Material flammability rating: UL 94V-2 • Adjustable, releasable, and re-useable multiple times; ideal for moves, adds, and changes Image 2 Part Number Image No. Length (In.) Width (In.) Max. Bundle Dia. (In.) HLTP2I-X12 1 8.00 0.50 1.91 Maroon 10 HLTP3I-X12 1 12.00 0.50 3.18 Maroon 10 Color Std. Pkg. Qty. HLTP2I-X0 1 8.00 0.50 1.91 Black 10 HLTP3I-X0 1 12.00 0.50 3.18 Black 10 JMDWB-3-X 7 Three-level drop wire bracket that attaches to #12 wire or 1/4" threaded rod. 10 HLSP1.5S-X12 2 6.00 0.75 1.50 Maroon 10 JMTRB38-1-X 8 Single-level threaded rod bracket; accepts 1/4" – 3/8" threaded rod. 10 HLSP3S-X12 2 12.00 0.75 3.20 Maroon 10 HLSP5S-X12 2 18.00 0.75 5.00 Maroon 10 JMTRB38-3-X 9 Three-level threaded rod bracket; accepts 1/4" – 3/8" threaded rod. 10 HLSP1.5S-X0 2 6.00 0.75 1.50 Black 10 JMSBCB87-1-X 10 Single-level screw-on beam clamp bracket for use with flanges up to 3/4" thick. 10 JMSBCB87-3-X 11 Three-level screw-on beam clamp bracket for use with flanges up to 3/4" thick. 10 H.61 Order number of pieces required, in multiples of Standard Package Quantity. HLSP3S-X0 2 12.00 0.75 3.20 Black 10 HLSP5S-X0 2 18.00 0.75 5.00 Black 10 Call 866-405-6654 or visit www.panduit.com/stronghold H.62 Supports & Fasteners Communications/ Low Voltage StrongHold™ Communications/Low Voltage Part Numbers Bridle Rings Referenced Images Contractor Grade Hook and Loop Cable Ties • Strong, low-profile, flexible material that is safe to use on high-performance cabling • Cost-effective for general bundling • Color: Black Part Number Length (Feet) Width (In.) Max. Bundle Dia. (In.) Std. Pkg. Qty. TTS-35R3-0 35.00 0.75 Various 1 pkg. of 3 rolls TTS-35RX0 35.00 0.75 Various 1 pkg. of 10 rolls TTS-75R0 75.00 0.75 Various 1 pkg. of 10 rolls H.63 Order number of pieces required, in multiples of Standard Package Quantity. Image 1 Image 2 Image 4 Image 5 Image 3 Call 866-405-6654 or visit www.panduit.com/stronghold H.64 Supports & Fasteners Communications/ Low Voltage Bridle Rings StrongHold™ Communications/Low Voltage Part Numbers Bridle Rings with Saddles • Plastic saddles allow bridle rings to be used for communication cable • Suitable for use in air handling spaces • Available pre-installed or can be ordered separately to be installed by the user • Suitable for low-voltage cabling • Not suitable for high-performance communication cabling • Variety of mounting options available to support specific application requirements Image 1 Part Number Image No. Description Std. Pkg. Qty. BR-.50-10-24 1 1/2" capacity – mounts with 10-24 threads. 100 BR-.75-10-24 1 3/4" capacity – mounts with 10-24 threads. 100 BR-1.25-10-24 1 1 1/4" capacity – mounts with 10-24 threads. 100 BR-2.0-10-24 1 2" capacity – mounts with 10-24 threads. 100 BR-1.25-1/4-20 1 1 1/4" capacity – mounts with 1/4"-20 threads. 100 BR-2.0-1/4-20 1 2" capacity – mounts with 1/4"-20 threads. 100 BR-4.0-1/4-20 1 4" capacity – mounts with 1/4"-20 threads. 50 BR-1.25-14WS 2 1 1/4" capacity – mounts with #14 wood screw thread. 100 BR-2.0-14WS 2 2" capacity – mounts with #14 wood screw thread. 100 BR-1.5-PAF 3 1 1/2" capacity – mounts with powder actuated fastener. 50 BR-2.0-PAF 3 2" capacity – mounts with powder actuated fastener. 50 BR-1.5-SN 4 1 1/2" capacity – mounts with screws, nails, or other user supplied fasteners. 100 BR-2.0-SN 4 2" capacity – mounts with screws, nails, or other user supplied fasteners. 100 BR-1.5-TW 5 1 1/2" capacity – mounts with toggle screw. 25 BR-2.0-TW 5 2" capacity – mounts with toggle screw. 25 H.65 Order number of pieces required, in multiples of Standard Package Quantity. Image 2 Part Number Image 3 Image No. Description Std. Pkg. Qty. BR-1.5-1/4-20S 1 Bridle ring with saddle – 1.5" capacity – mounts with 1/4-20 threads. 50 BR-2.0-1/4-20S 1 Bridle ring with saddle – 2" capacity – mounts with 1/4-20 threads. 50 BR-4.0-1/4-20S 1 Bridle ring with saddle – 4" capacity – mounts with 1/4-20 threads. 50 BR-1.5-14WSS 2 Bridle ring with saddle – 1.5" capacity – mounts with #14 wood screw threads. 50 BR-2.0-14WSS 2 Bridle ring with saddle – 2" capacity – mounts with #14 wood screw threads. 50 BRS-1.5 3 Saddle only for 1.5" – diameter bridle ring. 100 BRS-2.0 3 Saddle only for 2" – diameter bridle ring. 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.66 Supports & Fasteners Dry Wall Low-Voltage Mounting Brackets Image 1 Mount with self-tapping screws found on page H.49! StrongHold™ Dry Wall Part Numbers Old Work Box Mount • Prevents electrical box from pulling away from dry wall • Supports box to dry wall to prevent mounting directly to stud • Allows quick installation with no tools required • Manufactured from pre-galvanized steel • Choose design styles for new or retrofit installations • Available in both single and double gang configurations • Manufactured from galvanized steel materials Part Number PDSI2A Image 2 Part Number Image 3 Image No. Description Secures electrical box to dry wall. 100 Image 4 Description Std. Pkg. Qty. LV-S-1G 1 Single gang, low-voltage mounting bracket for new installations. 25 LV-S-2G 2 Double gang, low-voltage mounting bracket for new installations. 25 LV-W-1G 3 Single gang, low-voltage mounting bracket for retrofit installations; suitable for wall material thicknesses for 1/2" – 1 1/2". 100 LV-W-2G 4 Double gang, low-voltage mounting bracket for retrofit installations; suitable for wall material thicknesses for 1/2" – 1 1/2". 50 H.67 Std. Pkg. Qty. Order number of pieces required, in multiples of Standard Package Quantity. Wiring Device Retainer • Provides stability and prevents broken cover plates • Manufactured from pre-galvanized steel Part Number PRLC Description Std. Pkg. Qty. Mounts standard outlet or switch in oversized openings. 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.68 Supports & Fasteners Acoustical T-Bar Clip Top-Mount Assemblies Troffer Fastener Clip • Positive clip-on support for troffers/lay-in fixtures • Fits round or rectangular head T-bars • Complies with NEC Article 410.36 requirements (reference pages O.11 for details) • For upturned or straight lip fixtures Part Number P515A StrongHold™ Acoustical Part Numbers Description T-bar clip for troffers. Image 1 Std. Pkg. Qty. 100 Image 2 Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P8PATA 1 P12PATA 1 1/2 — 100 3/4 1/2 P16PATA 100 1 1 3/4 100 P6MATA 2 3/8* 3/8 100 P812MATA 2 1/2 – 3/4 1/2 – 3/4 100 P16MATA 2 1 1 100 Part Number T-Bar Clip *Or 14-2 through 12-3 MC/AC cable. • Supports outlet boxes above acoustical T-bar • Top-mounted applications • Used in conjunction with T-bar clip top-mount assemblies to eliminate the need for offset bending conduit • Meets NEC Article 300.11 requirements (reference page O.2 for details) Part Number PATA4I H.69 Description T-bar clip with 1/4-20 mounting hole. • For supporting conduit above acoustical T-bar • Top-mounted applications • Used in conjunction with T-bar clips mounted to electrical boxes to eliminate the need for offset bending conduit • Meet NEC Article 300.11 requirements (reference page O.2 for details) Std. Pkg. Qty. 100 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.70 Supports & Fasteners Acoustical T-Bar Clip Side-Mount Assemblies Image 1 StrongHold ™ Acoustical Part Numbers T-Bar Drop Wire Clip • Support conduit above acoustical T-bar in side-mounted applications • Used in conjunction with T-bar clips mounted to electrical boxes to eliminate the need for offset bending conduit • Meets NEC Article 300.11 requirements (reference page O.2 for details) • Provides a means to support fixtures from building structure instead of T-bar • Includes 5/8" stud and wing nut washer • Accommodates 1" T-bar • Manufactured from pre-galvanized materials Part Number PIDS Description T-bar drop wire clip for use with 1" T-bar. Static Load Rating (Lbs.) Std. Pkg. Qty. 65 50 Image 2 Image No. Fits EMT (In.) Fits Rigid/IMC (In.) Std. Pkg. Qty. P8PATS 1 P12PATS 1 1/2 — 100 3/4 1/2 P16PATS 100 1 1 3/4 100 P6MATS 2 3/8* 3/8 100 P812MATS 2 1/2 – 3/4 1/2 – 3/4 100 P16MATS 2 1 1 100 Part Number *Or 14-2 through 12-3 MC/AC cable. T-Bar Fastener • Provides method of attaching conduit and electrical boxes above T-bar • Allows secure screw attachment to T-bar • Eliminates offset bend in conduit Part Number P4ACS H.71 Order number of pieces required, in multiples of Standard Package Quantity. Description Conduit and box support for T-bar with 1/4-20 threaded impression. Call 866-405-6654 or visit www.panduit.com/stronghold Std. Pkg. Qty. 100 H.72 Supports & Fasteners Acoustical Box to T-Bar Fasteners Image 1 StrongHold ™ Acoustical Part Numbers Heavy Duty Adjustable Box Mounting Bar Hangers • Accommodate 24" T-bar span • Non-adjustable version is suitable for flush or offset mount • Adjustable version provides for 8" adjustments allowing the installation of double deep boxes, speaker cases, and emergency light fixtures above T-bar P512HDK • Box fastener adjustable for 16" – 24" ceiling joist/stud spacing • Allow versatility in installing electrical boxes along the length of the bar • Install quickly and easily between ceiling joists or wall studs Image 2 P512HDT Image 3 Part Number Image 4 Image No. Image 5 Description Description Std. Pkg. Qty. P512HDK Installs in 1/2" knockouts in bottom of electrical box. 50 P512HDT Includes 3/4" stud to accommodate fixture stems. 50 Part Number Std. Pkg. Qty. P512 1 Box to T-bar fastener for flush or 3/4" offset mount. 50 P512A 2 Box to T-bar fastener allows up to 8" of height adjustment. 25 PBHC* 3 Additional box mounting clip with screw for P512 and P512A. 100 P512HD 4 Heavy duty box to t-bar fastener for 24” span. Includes box mounting clip. 25 P510HD 5 Additional box mounting clip for P512HD. 100 *Not UL or cUL listed. H.73 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.74 Supports & Fasteners Acoustical T-Bar Assembly for Lighting Support StrongHold ™ Acoustical Part Numbers T-Bar Scissor Clips • Accommodates fixed 24" T-bar span • Allows for adjustable fixture position • Fits Lightolier 5 and Calculite* series fixtures • Support electrical fixtures or boxes to 1" wide T-bar • Include 1" wing nut washer (see page M.3) • Multiple stud lengths provided • No tools required for installation PPT16 Part Number P520 Std. Pkg. Qty. Description T-bar assembly that fits Lightolier 5 and Calculite* series fixtures. 25 *Lightolier and Calculite are trademarks of the Phillips group brand. P4G162 Part Number Description Std. Pkg. Qty. PPT16 T-bar scissor clip with 1/4-20 x 5/8" stud. 50 P4G162 T-bar scissor clip with 1/4-20 x 2" stud. 50 Twist-On T-Bar Hanger • Easily twists onto T-bar to support electrical fixtures • Accommodates T-bar 15/16" wide • Includes 1" wing nut washer (see page M.3) Part Number P4G16 H.75 Description Twist-on T-bar hanger with 1/4-20 x 5/8" long threaded stud. Static Load Rating (Lbs.) Std. Pkg. Qty. 50 100 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold H.76 Supports & Fasteners Acoustical Independent Drop Wire Clips PEC311 Fluorescent Light Fixture Hanger • Prevent sway of dedicated drop wire • Satisfy NEC Article 300.11 code requirements (reference page O.2 for details); consult local authority • Yellow color provides easy identification by inspectors • Fits most fluorescent light fixtures • Allows quick installation with no tools required • Provides an easy method to support an industrial class fluorescent light fixture Image 1 Image 2 PEC3114Z34 Part Number Description Std. Pkg. Qty. PEC311 Independent drop wire clip. 100 PEC3114Z34 Independent drop wire clip with spring steel drop wire clip. 100 H.77 StrongHold ™ Acoustical Part Numbers Order number of pieces required, in multiples of Standard Package Quantity. Part Number Image No. Description Std. Pkg. Qty. PLFC 1 Side mount fixture clip. 100 PLFC90 2 Top mount fixture clip. 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.78 Supports & Fasteners Miscellaneous StrongHold ™ Miscellaneous Part Numbers Rod Hanger for Non-Threaded Rod Rod Hangers with Threaded Impressions • Friction fit prevents the need for additional hardware • Static load capacity: 160 lbs. • Prevent the need for additional nuts • Include 1/4" mounting hole in top for assemblies • Static load capacity: 160 lbs. Part Number Description Std. Pkg. Qty. P4TI Accommodates 1/4-20 threaded rod. 100 Part Number P6TI Accommodates 3/8-16 threaded rod. 100 P6A Description Std. Pkg. Qty. 3/8" non-threaded rod. 100 Rod Hanger for Drop Wire or Non-Threaded Rod • Friction fit prevents the need for additional hardware • Two windows provide most suitable fit for multiple diameter wire/rod. • Static load capacity: 160 lbs. Part Number P708 H.79 Order number of pieces required, in multiples of Standard Package Quantity. Description Std. Pkg. Qty. Rod hanger for #8 wire or 1/4" plain rod. Call 866-405-6654 or visit www.panduit.com/stronghold 100 H.80 Supports & Fasteners Miscellaneous Wing Nut Washer StrongHold ™ Miscellaneous Part Numbers Brackets • Used in conjunction with products with 1/4-20 stud • Manufactured from pre-galvanized steel • Suitable to be installed by hand; no tools required • Not to exceed load rating of the corresponding fastener Part Number P4WN Description Wing nut washer fits 1/4-20 stud. PAO Std. Pkg. Qty. 100 PAB Part Number H.81 • Utilized for assemblies or a variety of other applications • Prevents conduit bends to accommodate electrical boxes • Static load capacity: 160 lbs. Order number of pieces required, in multiples of Standard Package Quantity. Description Std. Pkg. Qty. PAO Offset bracket with two 1/4" non-threaded holes. 100 PAB Right angle bracket with two 1/4" non-threaded holes. 100 Call 866-405-6654 or visit www.panduit.com/stronghold H.82 Duct Seal Cable Ties Panduit's duct seal is easy to use and helps to seal irregular openings from air, dust, or water. It is also a non-corrosive and non-toxic safe material, while providing vibration dampening. StrongHold Cable TiePart PartNumbers Numbers Panduit ® ™Duct Seal Duct Seal — ­ Sealing Compounds • Seals irregular openings from air, dust, or water • Non-hardening sealant that adheres to metal, masonry, wood or plastic • Provides vibration dampening • Safe and easy to use, non-corrosive, non-toxic, no asbestos, will not stain or harm hands, and no unpleasant odor • Dielectric strength: 200 V/Mil, Min 0.030" thick • Temperature range: -30°F – 210°F (-34°C ­– 98°C) • 10 year minimum shelf life • Indoor use only Part Number I.1 Order number of pieces required, in multiples of Standard Package Quantity. Part Description DS1 Duct seal (sealing compound) 1 lb. package DS5 Duct seal (sealing compound) 5 lb. package Std. Pkg. Qty. 1 Call 866-405-6654 or visit www.panduit.com/stronghold I.2 NetKey® Cabling System The Keystone Copper Cabling System provides a complete component and standards compliant cabling infrastructure solution for voice, data and video applications. Keystone modules feature the universal “keystone” design and are compatible with a wide assortment of modular patch panels, faceplates, and surface mount boxes. When combined with complementary Panduit products, NetKey® connectivity provides solutions from the telecommunication room to the work area with proven innovation and quality. NetKey ® Cabling System Part Numbers NetKey ® Category 6A, 6 and 5e Jack Modules � Meet all industry performance standards for Category 6A, 6 and 5e � Punchdown jack modules are 100% performance tested and individually serialized for future traceability � Keystone punchdown jacks meet ANSI/TIA 568-C.2 and ISO 11801 component requirements � Snap in and out of keystone openings for easy moves, adds and changes � Universal label includes T568A and T568B wiring schemes NK6X88MIW NK688MIW NKP5E88MIW Part Number Description Color Std. Pkg. Qty. Std. Ctn. Qty. NetKey ® Category 6A UTP Jack Modules* NK6X88MIW Category 6A, component compliant, 8-position, 8-wire keystone punchdown jack module. Off White 1 50 NK6X88MIW-Q Convenience pack of 25, Category 6A, component compliant, 8-position, 8-wire keystone punchdown jack modules. Off White 25 250 *For standard colors other than IW (Off White), replace IW in part number with EI (Electric Ivory), IG (International Gray), WH (White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet). J.1 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.2 Cabling System NetKey® NetKey ® Category 6A, 6 and 5e Jack Modules (continued) NetKey ® Cabling System Part Numbers NetKey ® Copper UTP Patch Cords � Meets all industry performance standards for Category 6A, 6 and 5e � 100% performance tested � Available in a variety of colors and lengths for design flexibility NK688MIW NKP5E88MIW Part Number Description Color Std. Pkg. Qty. Std. Ctn. Qty. 50 NetKey ® Category 6 UTP Jack Modules NK688MIW NK688MIW-Q Category 6, component compliant, 8-position, 8-wire, keystone punchdown jack module. Off White 1 Convenience pack of 25, Category 6, component compliant, 8-position, 8-wire, keystone punchdown jack modules. Off White 25 250 Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. 1 10 1 10 1 10 Category 6A UTP Patch Cord NK6APC^* NetKey Category 5e UTP Jack Modules*  ® NKP5E88MIW Category 5e, component compliant, 8-position, 8-wire, keystone punchdown jack module. Off White 1 50 NKP5E88MIW-Q Convenience pack of 25, Category 5e, component compliant, 8-position, 8-wire, keystone punchdown jack modules. Off White 25 250 *For standard colors other than IW (Off White), replace IW in part number with EI (Electric Ivory), IG (International Gray), WH (White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet). J.3 NK5EPC^*Y NK6APC^* NK6PC^*Y Order number of pieces required, in multiples of Standard Package Quantity. Category 6A, UTP patch cord with modular plugs on each end. Category 6 UTP Patch Cord NK6PC^*Y Category 6, UTP patch cord with modular plugs on each end. Category 6 UTP Patch Cord NK5EPC^*Y Category 5e, UTP patch cord with modular plugs on each end. ^Available in 3, 5, 7, 10, 14 and 20-foot lengths. *For standard colors other than Off White, add suffix BU (Blue), RD (Red), YL (Yellow) or GR (Green) before Y in the part number. For example, the part number of a blue, Category 6, 5-foot patch cord is NK6PC5BUY. Call 866-405-6654 or visit www.panduit.com/stronghold J.4 Cabling System NetKey® NetKey ® Keystone Patch Panels NetKey ® Cabling System Part Numbers NetKey ® Keystone Patch Panels (continued) �M  ounts to standard ANSI/TIA 19" racks �P  unchdown patch panels meet all industry performance standards for Category 6A, 6, and 5e �M  odular patch panels accept all NetKey® Modules �O  ptional angeld versions available for high density installations �O  ptional strain relief bars assist in cable management and bend radius control �N  ot compatible with Mini-Com® Jacks and Modules NK6PPG12WY NK5EPPG12WY Part Number NKFP12W Description Std. Pkg. Qty. Std. Ctn. Qty. Punchdown Patch Panels - Category 6 NKA6XPPG24Y NK6XPPG24Y Part Number Description Std. Pkg. Qty. Std. Ctn. Qty. NK6PPG12WY Category 6, 12-port punchdown patch panel. Mounts to wall with standard 89D bracket (WB89D). 1 10 NKA6PPG24Y Category 6, 24-port, angled punchdown patch panel, 1 RU. 1 10 NKA6PPG48Y Category 6, 48-port, angled punchdown patch panel, 2 RU. 1 10 Punchdown Patch Panels - Category 6A NKA6XPPG24Y Category 6A angled punchdown patch panel, 24 port, 1 RU. 1 10 NK6PPG24Y Category 6, 24-port, punchdown patch panel, 1 RU. 1 10 NKA6XPPG48Y Category 6A angled punchdown patch panel, 48 port, 2 RU. 1 10 NK6PPG48Y Category 6, 48-port, punchdown patch panel, 2 RU. 1 10 NK6XPPG24Y Category 6A punchdown patch panel, 24 port, 1 RU. 1 10 NK6PPG48Y Category 6, 48-port, punchdown patch panel, 2 RU. 1 10 NK6XPPG48Y Category 6A punchdown patch panel, 48 port, 2 RU. 1 10 Punchdown Patch Panels - Category 5e NK5EPPG12WY Category 5e, 12-port punchdown patch panel. Mounts to wall with standard 89D bracket (WB89D). 1 10 NKA5EPPG24Y Category 5e, 24-port, angled punchdown patch panel, 1 RU. 1 10 NKA5EPPG48Y Category 5e, 48-port, angled punchdown patch panel, 2 RU. 1 10 NK5EPPG24Y Category 5e, 24-port, punchdown patch panel, 1 RU. 1 10 NK5EPPG48Y Category 5e, 48-port, punchdown patch panel, 2 RU. 1 10 *Punchdown patch panels are color-coded for T568A and T568B wiring schemes. *Punchdown patch panels are color-coded for T568A and T568B wiring schemes. J.5 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.6 NetKey® Cabling System NetKey ® Keystone Patch Panels (continued) NetKey ® Cabling System Part Numbers NetKey ® Keystone Patch Panels (continued) NKFP24Y SRB19BLY NKPPA48FMY NKFP48Y Part Number WB89D Description Std. Std. Pkg. Ctn. Qty. Qty. Std. Pkg. Qty. Std. Ctn. Qty. Wall mount bracket. Ideal for use with 12-port punchdown or modular patch panels. 1 10 SRB19BLY Strain relief bar extends 2" from standard 19" rack for additional cable support. 1 10 SRBM19BLY Strain relief bar and Tak-Ty ® Hook & Loop Cable Ties for additional cable support. 1 10 SRBS19BL-XY Straight strain relief bar. 1 10 Part Number NKFP12W 12-port modular patch panel with front removable faceplate. Mounts to wall with standard 89D bracket (WB89D). 1 10 NKFP24Y 24-port modular patch panel with front removable faceplate, 1 RU. 1 10 NKFP48Y 48-port modular patch panel with front removable faceplate, 2 RU. 1 10 NKPPA24FMY 24-port flush mount angled modular patch panel, 1 RU. 1 10 NKPPA48FMY 48-port flush mount angled modular patch panel, 2 RU. 1 10 NKPP24FMY 24-port flush mount modular patch panel, 1 RU. 1 10 NKPP48FMY 48-port flush mount modular patch panel, 2 RU. 1 10 NK6XPPG48Y Category 6A punchdown patch panel, 48 port, 2 RU. 1 10 Description Wall Mount Bracket WB89D Modular Patch Panels SRBM19BLY Strain Relief Bars *Punchdown patch panels are color-coded for T568A and T568B wiring schemes. *Punchdown patch panels are color-coded for T568A and T568B wiring schemes. J.7 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.8 Cabling System NetKey® NetKey ® Cabling System Part Numbers NetKey ® Keystone Faceplates NetKey ® Snap-On Sloped Keystone Faceplates �M  ounts to standard ANSI/TIA 19" racks � Accept all Panduit ® NetKey ® Keystone Copper Modules and Duplex Fiber Optic Modules �P  unchdown patch panels meet all industry performance standards for Category 6A, 6, and 5e �M  odular patch panels accept all NetKey® Modules � Snap into raceway channel, requires no additional mounting hardware or adapters - greatly reducing installation time � Modular patch panels accept all NetKey® Modules �O  ptional angeld versions available for high density installations �O  ptional strain relief bars assist in cable management and bend radius control � Lowest cost for moves, adds, and changes �N  ot compatible with Mini-Com® Jacks and Modules �C  an be used with Pan-Way ® Cove, TG-70, T70, Twin-70, T-45 Raceway Systems, Fast-Snap™ Outlet Boxes, and Pan-Pole™ Aluminum Outlet Poles NK2FNIW NK2FIWY Part Number NK2HSFIWY NK4VSFIWY Description � Tamper resistant NKF2S Std. Pkg. Qty. Std. Ctn. Qty. 1 10 NK2HSRF NK4HSRF NK4VSRF Flush Mount Screw-On Faceplates NK*FNIW Single gang, flush mount vertical faceplate. NK**FIWY Single or double gang, flush mount vertical faceplate with labels. 1 10 NK^HSFIWY Single gang, sloped, horizontal faceplate with labels. 1 10 Single gang, 4-port, sloped, vertical faceplate with labels. 1 10 1 10 NK4VSF Part Number NK2HSRFIW Snap‑On 2-position sloped horizontal faceplate accepts any Panduit ® NetKey ® Module. Compatible with Panduit ® NetKey ® Outlet Boxes, Surface Raceway Systems, and Pan‑Pole™ Outlet Poles. Off White 1 10 NK4HSRFIW Snap‑On 4-position sloped horizontal faceplate accepts any Panduit ® NetKey ® Module. Compatible with Panduit ® NetKey ® Outlet Boxes, Surface Raceway Systems, and Pan‑Pole™ Outlet Poles. Off White 1 10 NK4VSRFIW Snap‑On 4-position sloped vertical faceplate accepts any Panduit ® NetKey ® Module. Compatible with Panduit ® NetKey ® Outlet Boxes, Surface Raceway Systems, and Pan‑Pole™ Outlet Poles. Off White 1 10 Stainless Steel Faceplates NKF^­^S Single gang, stainless steel, vertical faceplate with labels. Description Std. Std. Pkg. Ctn. Color‡ Qty. Qty. Panduit ® NetKey ® faceplates are NOT compatible with Panduit ® Mini‑Com ® Modules. ‡For other colors replace IW (Off White) with EI (Electric Ivory), IG (International Gray), or WH (White). For complete labeling solutions refer to www.panduit.com. J.9 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.10 Cabling System NetKey® NetKey ® Cabling System Part Numbers NetKey ® Keystone Module Frame and Furniture Faceplates NetKey ® Snap-On Flush Universal Keystone Faceplates �W  ider module spacing to accept common manufacturers' keystone modules 0.900 inches wide or less �C  an be used with Pan-Way ® Cove, TG-70, T70, Twin-70, T-45 Raceway Systems, Fast-Snap™ Outlet Boxes, and Pan-Pole™ Aluminum Outlet Poles NK2106MFIW Part Number T70KW2IW T70KW4IW Std. Std. Pkg. Ctn. Color‡ Qty. Qty. Part Number Description T70KW2IW Snap‑On 2-position flush mount faceplate accepts any Panduit ® NetKey ® Module and most other manufacturers’ keystone modules. Compatible with Panduit ® Fast-Snap™ Outlet Boxes, Surface Raceway Systems, and Pan‑Pole™ Outlet Poles. Off White Snap‑On 4-position flush mount faceplate accepts any Panduit ® NetKey ® Module and most other manufacturers’ keystone modules. Compatible with Panduit ® Fast-Snap™ Outlet Boxes, Surface Raceway Systems, and Pan‑Pole™ Outlet Poles. Off White T70KW4IW 1 1 10 J.11  ®  ®  ® Order number of pieces required, in multiples of Standard Package Quantity. NK2RMFIW NK4RMFIW Description NK4MFIW Std. Std. Pkg. Ctn. Color‡ Qty. Qty. NK2106MFIW Screw mount “106” duplex module frame. Accepts two NetKey ® Modules. Off White 1 10 NK4106MFIW Screw mount “106” duplex module frame. Accepts four NetKey ® Modules. Off White 1 10 NK2RMFIW Screw mount module frame. Accepts two NetKey ® Modules. Compatible with standard NEMA outlet boxes and rectangular faceplates. Off White 1 10 NK4RMFIW Screw mount module frame. Accepts four NetKey ® Modules. Compatible with standard NEMA outlet boxes and rectangular faceplates. Off White 1 10 NK4MFIW Snap on modular furniture faceplate. Accepts four NetKey ® Modules. Off White 1 10 10 Panduit NetKey faceplates are NOT compatible with Panduit Mini‑Com Modules. ‡For other colors replace IW (Off White) in part number with EI (Electric Ivory), IG (International Gray), or WH (White). For complete labeling solutions refer to www.panduit.com.  ® NK4106MFIW ‡For standard colors other than Off White, replace IW in part number with EI (Electric Ivory), WH (White), IG (International Gray) or BL (Black). Call 866-405-6654 or visit www.panduit.com/stronghold J.12 Cabling System NetKey® NetKey ® Cabling System Part Numbers NetKey ® Keystone Surface Mount Boxes Keystone Phone Plates � Accepts all Panduit ® NetKey ® Modules � Includes mounting screws and adhesive tap � Compatible with Panduit ® LE3, SD5, and LD10 Raceway � Not Compatible with Mini-Com ® Jacks and Modules KWPY Part Number KWP3Y Description Std. Std. Pkg. Ctn. Qty. Qty. KWPY Stainless steel wall phone plate accepts one module. 1 10 KWP3Y Stainless steel wall phone plate supplied with one Category 3 keystone leadframe module. 1 10 Wall mount faceplate kits compatible with wall mountable phones with short patch cord connections to the jack module. NK2BXIW-A Part Number NK4BXIW-AY NK6BXIW-AY Description CBM-X Std. Std. Pkg. Ctn. Color‡ Qty. Qty. NK2106MFIW Screw mount “106” duplex module frame. Accepts two NetKey ® Modules. Off White 1 10 NK4106MFIW Screw mount “106” duplex module frame. Accepts four NetKey ® Modules. Off White 1 10 NK2RMFIW Screw mount module frame. Accepts two NetKey ® Modules. Compatible with standard NEMA outlet boxes and rectangular faceplates. Off White 1 10 NK4RMFIW Screw mount module frame. Accepts four NetKey ® Modules. Compatible with standard NEMA outlet boxes and rectangular faceplates. Off White 1 10 NK4MFIW Snap on modular furniture faceplate. Accepts four NetKey ® Modules. Off White 1 10 ‡For surface mount box standard colors other than IW (Off White), replace suffix with EI (Electric Ivory), IG (International Gray) or WH (White). J.13 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.14 Cabling System NetKey® Termination Tool NetKey ® Audio/Video Modules NKFIW NKBNCMIWY Part Number NKHDMIIW NKUSBAAIW Description NKBMIW-X Color‡ Std. Pkg. Qty. Std. Ctn. Qty. Part Number Description Std. Std. Pkg. Ctn. Qty. Qty. F-Type Module F-Type Module NKFIW NetKey ® Cabling System Part Numbers Off White 1 10 Keystone module supplied with 50 ohm industry standard coax bulkhead coupler. Off White 1 10 Keystone module supplied with one HDMI 1.3 Type A female to female coupler module. Off White 1 10 Keystone module supplied with one USB 2.0 female A to female A coupler module. Off White 1 10 Blank keystone module reserves space for future use. Off White 1 10 Keystone module supplied with 75 ohm industry standard F-Type coax bulkhead coupler. NKSPB Base used to assist in terminating keystone punchdown modules. 1 10 50 Ohm BNC Coax Module NKBNCMIWY HDMI Coupler NKHDMIIW USB Coupler NKUSBAAIW Blank Module NKBMIW-X ‡For standard colors other than IW (Off White), replace IW in part number with EI (Electric Ivory), WH (White), IG (International Gray) or BL (Black). 5-Way Binding Post Module (NKBP^IWY ) only available in EI (Electric Ivory) and WH (White). J.15 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold J.16 Convenient Sizing Information Rigid Steel Conduit Electrical Metallic Tubing (EMT) Min. Weight Per 100 Ft. w/ Couplings Attached (Lbs.) Weight of Conduit and Conductors Per 100 Ft. (Lbs.) 0.58 23.00 0.71 28.50 0.82 0.92 1.05 1.16 Trade Size (In.) Nominal Inside Dia.* (In.) Nominal Outside Dia. (In.) 0.38 0.49 0.50 0.62 0.75 1.00 1.25 1.38 1.51 StrongHold ™ Convenient Sizing Information Weight of Conduit and Conductors Per 100 Ft. (Lbs.) Trade Size (In.) Nominal Inside Dia.* (In.) Nominal Outside Dia. (In.) Min. Weight Per 100 Ft. w/ Couplings Attached (Lbs.) 36.60 0.38 0.49 0.68 51.50 65.10 50.60 0.50 0.63 0.84 79.00 101.00 43.50 84.30 0.75 0.84 1.05 105.00 145.80 64.00 130.30 1.00 1.06 1.32 153.00 219.30 212.30 1.25 1.39 1.66 201.00 318.30 1.62 1.90 249.00 408.80 593.80 95.00 1.50 1.61 1.74 110.00 269.80 1.50 2.00 2.07 2.20 140.00 401.80 2.00 2.08 2.38 332.00 2.50 2.73 2.88 205.00 579.00 2.50 2.49 2.88 527.00 901.00 3.00 3.36 3.50 250.00 826.30 3.00 3.09 3.50 682.60 1259.00 3.50 3.83 4.00 325.00 1098.00 3.50 3.57 4.00 831.00 1604.00 1364.00 4.00 4.05 4.50 972.30 1967.00 Trade Size (In.) Nominal Inside Dia.* (In.) Nominal Outside Dia. (In.) Min. Weight Per 100 Ft. w/ Couplings Attached (Lbs.) Weight of Conduit and Conductors Per 100 Ft. (Lbs.) 0.50 0.63 0.84 27.40 49.50 0.75 0.84 1.05 36.40 77.20 1.00 1.06 1.32 53.00 119.30 1.25 1.39 1.66 69.60 186.90 1.50 1.62 1.90 82.20 242.00 2.00 2.08 2.38 115.70 377.50 2.50 2.49 2.88 182.50 556.50 3.00 3.09 3.50 238.90 815.20 3.50 3.57 4.00 287.70 1061.00 4.00 4.05 4.50 340.00 1334.00 5.00 5.07 5.56 465.40 2028.00 6.00 6.09 6.63 612.50 2870.00 4.00 4.33 4.50 370.00 *Per UL table NAE.3. *Per UL table NAE.3. Intermediate Metal Conduit (IMC) Rigid Aluminum Conduit Trade Size (In.) Nominal Inside Dia.* (In.) Nominal Outside Dia. (In.) Min. Weight Per 100 Ft. w/ Couplings Attached (Lbs.) Weight of Conduit and Conductors Per 100 Ft. (Lbs.) 0.50 0.68 0.82 60.00 82.10 0.75 0.88 1.03 82.00 122.80 1.00 1.12 1.29 116.00 182.30 1.25 1.47 1.64 150.00 267.30 1.50 1.70 1.88 182.00 341.80 2.00 2.17 2.36 242.00 503.80 2.50 2.60 2.86 401.00 775.00 3.00 3.22 3.48 493.00 1069.00 3.50 3.71 3.97 573.00 1346.00 4.00 4.21 4.47 638.00 1632.00 *Per UL table NAE.3. *Per UL table NAE.3. K.1 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold K.2 Convenient Sizing Information Electrical Non-Metallic Tubing (ENT) StrongHold ™ Convenient Sizing Information MC Cable Min. Weight of Conduit Per 100 Ft. (Lbs.) Weight of Conduit and Conductors Per 100 Ft. (Lbs.) AWG Size Insulated Ground Nominal Outside Dia. (In.) Bare Ground Nominal Outside Dia. (In.) 0.84 11.00 33.10 14-2 Solid 0.45 0.43 14-3 Solid 0.48 0.76 1.05 14.00 0.44 54.80 14-4 Solid 0.51 1.00 1.00 1.32 0.49 20.00 86.30 12-2 Solid 0.50 1.25 1.40 0.47 1.66 19.00 136.30 12-3 Solid 0.53 1.50 0.50 1.55 1.99 27.00 186.80 12-4 Solid 0.57 2.00 0.56 2.03 2.38 32.00 261.80 10-2 Solid 0.56 0.52 10-3 Solid 0.60 0.55 10-4 Solid 0.65 0.62 8-2 Stranded 0.71 0.68 8-3 Stranded 0.77 0.71 8-4 Stranded 0.84 0.77 6-2 Stranded 0.80 0.76 6-3 Stranded 0.87 0.80 Trade Nominal Size (In.) Nominal Inside Dia.* (In.) Nominal Outside Dia. (In.) 0.50 0.56 0.75 *Per UL table NAE.3. Schedule 40 PVC Plastic Pipe Nominal Pipe Size (In.) Outside Dia. (In.) Wall Thickness (In.) Weight of Pipe Per Ft. (Lbs.) Weight of Water Per Ft. (Lbs.) 0.13 0.41 0.07 0.04 0.02 6-4 Stranded 0.95 0.87 0.25 0.54 0.09 0.07 0.04 4-2 Stranded 0.95 0.90 0.38 0.68 0.09 0.10 0.08 4-3 Stranded 1.04 0.95 0.50 0.84 0.11 0.15 0.1 4-4 Stranded 1.14 0.10 0.75 1.05 0.11 0.20 0.20 2-2 Stranded 1.08 0.10 1.00 1.32 0.13 0.30 0.40 2-3 Stranded 1.18 1.08 1.25 1.66 0.14 0.40 0.60 2-4 Stranded 1.30 1.18 1.50 1.90 0.15 0.50 0.90 2.00 2.38 0.15 0.60 1.40 2.50 2.88 0.20 1.00 2.10 3.00 3.50 0.22 1.30 3.20 3.50 4.00 0.23 1.60 4.30 4.00 4.50 0.24 1.90 5.50 All Threaded Rod (ATR) K.3 Design Load SF = 5 Nominal Size and Thread In.2 cm2 Lbs. kN 1/4-20 0.03 0.17 240.00 1.07 5/16-18 0.05 0.29 400.00 1.78 3/8-16 0.07 0.44 610.00 2.71 Root Area Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold K.4 Convenient Sizing Information Type NM – Non-Metallic Sheathed Cable 1.23 1.07 0.88 0.76 — — — — 1.12 — — 0.97 — — 0.81 — 0.71 0.70 0.65 0.59 — 0.54 0.55 — 0.52 Stranded Solid 0.52 — Stranded Ground Wire Size Approximate Outside Dia. (In.) Approximate Weight Per 100 Ft. (Lbs.) Without Ground Wire 0.49 Solid AWG Size No. of Strands 14-2 Solid — 0.17 x 0.37 5.30 12-2 Solid — 0.19 x 0.40 7.00 10.10 10-2 Solid — 0.22 x 0.45 14-3 Solid — 0.30 8.20 12-3 Solid — 0.33 10.90 10-3 Solid — 0.40 15.70 8-3 7 — 0.54 27.80 6-3 7 — 0.61 42.20 1.01 — 0.96 — 14-2 Solid 14 0.17 x 0.37 6.40 12-2 Solid 12 0.19 x 0.41 9.00 10-2 Solid 10 0.22 x 0.49 13.30 8-2 7 10 0.28 x 0.61 21.50 6-2 7 10 0.32 x 0.73 31.30 14-3 Solid 14 0.32 9.30 12-3 Solid 12 0.36 12.90 10-3 Solid 10 0.44 18.70 14-4 Solid 14 0.45 11.60 12-4 Solid 12 0.49 16.10 10-4 Solid 10 0.55 23.30 8-3 7 10 0.55 30.50 6-3 7 10 0.61 45.00 4-3 7 8 0.82 66.40 2-3 7 8 0.95 93.00 2 0.89 — 0.84 — 4 0.74 — 0.70 — 6 0.64 0.60 0.60 0.57 THHN ACTMM 8 — 0.50 — 0.48 10 — 0.49 — 0.48 12 — 0.45 Solid Stranded — 0.43 Solid Type of Circuit Conductors Type of Armored Cable 14 Stranded With Ground Wire AWG Size of Circuit Conductors Cable with Two Circuit Conductors and No Grounding Conductor (In.) Cable with Three Circuit Conductors and No Grounding Conductor, and Cable with Two Circuit Conductors and a Grounding Conductor (In.) Minimum External Diameter of Armor Cable with Four Circuit Conductors and No Grounding Conductor, and Cable with Three Circuit Conductors and a Grounding Conductor (In.) Cable with Four Circuit Conductors and a Grounding Conductor (In.) AC Cable K.5 StrongHold ™ Convenient Sizing Information Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold K.6 Convenient Sizing Information Type THHN – Insulated Single Conductor Building Wire StrongHold ™ Convenient Sizing Information Communication Cable Size (AWG) Armor Outside Dia. (In.) Approximate Weight Per 100 Ft. (Lbs.) Cable Type Diameter (In.) Category 6A 0.300 14 0.11 1.70 Category 6A (SD) 0.240 12 0.13 2.50 Category 6 0.240 10 0.16 4.00 Category 5e 0.225 8 0.22 6.50 6 0.25 9.70 4 0.32 15.50 3 0.35 19.10 2 0.38 23.60 1 0.45 30.40 1/0 0.49 37.50 J-Pro™ Capacity J-Pro™ Family Category 6A (0.300") Category 6A (SD) (0.240") Category 6 (0.240") Category 5e (0.225") JP75 5 8 8 10 JP131 15 25 25 29 JP2 30 46 46 55 JP4 115 180 180 200 Note: The above cable diameters represent the nominal Panduit cable diameter per performance level. For specific cable fill information based on specific part numbers, please contact customer service. K.7 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold K.8 Codes and Standards NFPA 70; National Electric Code; 2014 Revision 90.4 Enforcement. This Code is intended to be suitable for mandatory application by governmental bodies that exercise legal jurisdiction over electrical installations, including signaling and communications systems, and for use by insurance inspectors. The authority having jurisdiction for enforcement of the Code has the responsibility for making interpretations of the rules, for deciding on the approval of equipment and materials, and for granting the special permission contemplated in a number of the rules. By special permission, the authority having jurisdiction may waive specific requirements in this Code or permit alternative methods where it is assured that equivalent objectives can be achieved by establishing and maintaining effective safety. This Code may require new products, constructions, or materials that may not yet be available at the time the Code is adopted. In such event, the authority having jurisdiction may permit the use of the products, constructions, or materials that comply with the most recent previous edition of this Code adopted by the jurisdiction. 300.4 Protection Against Physical Damage. (B) Nonmetallic-Sheathed Cables and Electrical Nonmetallic Tubing through Metal Framing Members. (1) Nonmetallic-Sheathed Cable. In both exposed and concealed locations where nonmetallic-sheathed cables pass through either factory- or field-punched, cut, or drilled slots or holes in metal members, the cable shall be protected by listed bushings or listed grommets covering all metal edges that are securely fastened in the opening prior to installation of the cable. (D) Cables and Raceways Parallel to Framing Members and Furring Strips. In both exposed and concealed locations, where a cable- or raceway-type wiring method is installed parallel to framing members, such as joists, rafters, or studs, or is installed parallel to furring strips, the cable or raceway shall be installed and supported so that the nearest outside surface of the cable or raceway is not less than 32mm (1 1⁄4 in.) from the nearest edge of the framing member or furring strips where nails or screws are likely to penetrate. Where this distance cannot be maintained, the cable or raceway shall be protected from penetration by nails or screws by a steel plate, sleeve, or equivalent at least 1.6mm (1⁄16 in.) thick. Exception No. 1: Steel plates, sleeves, or the equivalent shall not be required to protect rigid metal conduit, intermediate metal conduit, rigid nonmetallic conduit, or electrical metallic tubing. Exception No. 2: For concealed work in finished buildings, or finished panels for prefabricated buildings where such supporting is impracticable, it shall be permissible to fish the cables between access points. Exception No. 3: A listed and marked steel plate less than 1.6mm (1⁄16 in.) thick that provides equal or better protection against nail or screw penetration shall be permitted. L.1 Order number of pieces required, in multiples of Standard Package Quantity. StrongHold ™ Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) 300.11 Securing and Supporting. (A) Secured in Place. Raceways, cable assemblies, boxes, cabinets, and fittings shall be securely fastened in place. Support wires that do not provide secure support shall not be permitted as the sole support. Support wires and associated fittings that provide secure support and that are installed in addition to the ceiling grid support wires shall be permitted as the sole support. Where independent support wires are used, they shall be secured at both ends. Cables and raceways shall not be supported by ceiling grids. (1) Fire-Rated Assemblies. Wiring located within the cavity of a fire-rated floor-ceiling or roof-ceiling assembly shall not be secured to, or supported by, the ceiling assembly, including the ceiling support wires. An independent means of secure support shall be provided and shall be permitted to be attached to the assembly. Where independent support wires are used, they shall be distinguishable by color, tagging, or other effective means from those that are part of the fire-rated design. Exception: The ceiling support system shall be permitted to support wiring and equipment that have been tested as part of the fire-rated assembly. Informational Note: One method of determining fire rating is testing in accordance with ANSI/ASTM E119-2012a, Method for Fire Tests of Building Construction and Materials. (2) Non-Fire-Rated Assemblies. Wiring located within the cavity of a non-fire-rated floor-ceiling or roof-ceiling assembly shall not be secured to, or supported by, the ceiling assembly, including the ceiling support wires. An independent means of secure support shall be provided and shall be permitted to be attached to the assembly. Where independent support wires are used, they shall be distinguishable by color, tagging, or other effective means. Exception: The ceiling support system shall be permitted to support branch-circuit wiring and associated equipment where installed in accordance with the ceiling system manufacturer’s instructions. 300.22 Wiring in Ducts not used for Air Handling, Fabricated Ducts for Environmental Air, and other Spaces for Environmental Air (Plenums). The provisions of this section shall apply to the installation and uses of electrical wiring and equipment in ducts used for dust, loose stock, or vapor removal; ducts specifically fabricated for environmental air; and other spaces used for environmental air (plenums). Informational Note: See Article 424, Part VI, for duct heaters. (A) Ducts for Dust, Loose Stock, or Vapor Removal. No wiring systems of any type shall be installed in ducts used to transport dust, loose stock, or flammable vapors. No wiring system of any type shall be installed in any duct, or shaft containing only such ducts, used for vapor removal or for ventilation of commercial-type cooking equipment. Call 866-405-6654 or visit www.panduit.com/stronghold L.2 Codes and Standards L.3 StrongHold ™ Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) NFPA 70; National Electric Code; 2014 Revision (continued) (B) Ducts Specifically Fabricated for Environmental Air. Equipment, devices and the wiring methods specified in this section shall be permitted within such ducts only if necessary for the direct action upon, or sensing of, the contained air. Where equipment or devices are installed and illumination is necessary to facilitation maintenance and repair, enclosed gasketed-type luminaires shall be permitted. Only wiring methods consisting of Type MI cable without an overall nonmetallic covering, Type MC cable employing a smooth or corrugated impervious metal sheath without an overall nonmetallic covering, electrical metallic tubing, flexible metallic tubing, intermediate metal conduit, or rigid metal conduit without an overall nonmetallic covering shall be installed in ducts specifically fabricated to transport environmental air. Flexible metal conduit shall be permitted, in lengths not to exceed 1.2m (4 ft.), to connect physically adjustable equipment and devices permitted to be in these fabricated ducts. The connectors used with flexible metal conduit shall effectively close any openings in the connection. C) Other Spaces Used for Environmental Air (Plenums). This section shall apply to spaces not specifically fabricated for environmental air-handling purposes but used for air-handling purposes as a plenum. This section shall not apply to habitable rooms or areas of buildings, the prime purpose of which is not air handling. Informational Note No. 1: The space over a hung ceiling used for environmental air-handling purposes is an example of the type of other space to which this section applies. Informational Note No. 2: The phrase “Other Spaces Used for Environmental Air (Plenum)” as used in this section correlates with the use of the term “plenum” in NFPA 90A-2012, Standard for the Installation of Air-Conditioning and Ventilating Systems, and other mechanical codes where the plenum is used for return air purposes, as well as some other air-handling spaces. Exception: This section shall not apply to the joist or stud spaces of dwelling units where the wiring passes through such spaces perpendicular to the long dimension of such spaces. (1) Wiring Methods. The wiring methods for such other space shall be limited to totally enclosed, nonventilated, insulated busway having no provisions for plug-in connections, Type MI cable without an overall nonmetallic covering, Type MC cable without an overall nonmetallic covering, Type AC cable, or other factory-assembled multiconductor control or power cable that is specifically listed for use within an air-handling space, or listed prefabricated cable assemblies of metallic manufactured wiring systems without nonmetallic sheath. Other types of cables, conductors, and raceways shall be permitted to be installed in electrical metallic tubing, flexible metallic tubing, intermediate metal conduit, rigid metal conduit without an overall nonmetallic covering, flexible metal conduit, or, where accessible, surface metal raceway or metal wireway with metal covers. Nonmetallic cable ties and other nonmetallic cable accessories used to secure and support cables shall be listed as having low smoke and heat release properties. Informational Note: One method to determine low smoke and heat release properties is that the nonmetallic cable ties and other nonmetallic cable accessories exhibit a maximum peak optical density of 0.50 or less, an average optical density of 0.15 or less, and a peak heat release rate of 100kW or less when tested in accordance with ANSI/UL 2043-2008, Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces. 2) Cable Tray Systems. The provisions in (a) or (b) shall apply to the use of metallic cable tray systems in other spaces used for environmental air (plenums), where accessible, as follows: (a) Metal Cable Tray Systems. Metal cable tray systems shall be permitted to support the wiring methods in 300.22 (C)(1). (b) Solid Side and Bottom Metal Cable Tray Systems. Solid side and bottom metal cable tray systems with solid metal covers shall be permitted to enclose wiring methods and cables, not already covered in 300.22 (C)(1), in accordance with 392.10 (A) and (B). (3) Equipment. Electrical equipment with a metal enclosure, or electrical equipment with a nonmetallic enclosure listed for use within an air-handling space and having adequate fire-resistant and low-smoke-producing characteristics, and associated wiring material suitable for the ambient temperature shall be permitted to be installed in such other space unless prohibited elsewhere in this Code. Informational Note: One method of defining adequate fire-resistant and low-smoke producing characteristics for electrical equipment with a nonmetallic enclosure is in ANSI/UL 2043-2008, Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces. Exception: Integral fan systems shall be permitted where specifically identified for use within an air-handling space. (D) Information Technology Equipment. Electrical wiring in air-handling areas beneath raised floors for information technology equipment shall be permitted in accordance with Article 645. Order number of pieces required, in multiples of Standard Package Quantity. 310.15 Ampacities for Conductors Rated 0–2000 Volts. (B) Tables… (3) Adjustment Factors. (a) More Than Three Current-Carrying Conductors. Where the number of current-carrying conductors in a raceway or cable exceeds three, or where single conductors or multiconductor cables are installed without maintaining spacing for a continuous length longer than 600mm (24 in.) and are not installed in raceways, the allowable ampacity of each conductor shall be reduced as shown in Table 310.15 (B)(3)(a). Each current-carrying conductor of a paralleled set of conductors shall be counted as a current-carrying conductor. Call 866-405-6654 or visit www.panduit.com/stronghold L.4 Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) NFPA 70; National Electric Code; 2014 Revision (continued) Where conductors of different systems, as provided in 300.3, are installed in a common raceway or cable, the adjustment factors shown in Table 310.15 (B)(3)(a) shall apply only to the number of power and lighting conductors (Articles 210, 215, 220, and 230). Informational Note No. 1: See Annex B, for adjustment factors for more than three current-carrying conductors in a raceway or cable with load diversity. Informational Note No. 2: See 366.23 (A) for adjustment factors for conductors in sheet metal auxiliary gutters and 376.22 (B) for adjustment factors for conductors in metal wireways. (4) Adjustment factors shall not apply to Type AC cable or to Type MC cable under the following conditions: a. The cables do not have an overall outer jacket. b. Each cable has not more than three current-carrying conductors. c. The conductors are 12 AWG copper. d. Not more than 20 current-carrying conductors are installed without maintaining spacing, are stacked, or are supported on “bridle rings.” (5) An adjustment factor of 60 percent shall be applied to Type AC cable or Type MC cable under the following conditions: a. The cables do not have an overall outer jacket. b. The number of current carrying conductors exceeds 20. c. The cables are stacked or bundled longer that 600mm (24 in.) without spacing being maintained. a lampholder, or other equipment and is supported by entering raceways shall not exceed 1650cm3 (100 in.3) in size. It shall have threaded entries or identified hubs. It shall be supported by two or more conduits threaded wrenchtight into the enclosure or hubs. Each conduit shall be secured within 900mm (3 ft.) of the enclosure, or within 450mm (18 in.) of the enclosure if all conduit entries are on the same side. Exception: The following wiring methods shall be permitted to support a conduit body of any size, including a conduit body constructed with only one conduit entry, provided that the trade size of the conduit body is not larger than the largest trade size of the conduit or tubing: (1) Intermediate metal conduit, Type IMC (2) Rigid metal conduit, Type RMC (3) Rigid polyvinyl chloride conduit, Type PVC (4) Reinforced thermosetting resin conduit, Type RTRC (5) Electrical metallic tubing, Type EMT (F) Raceway-Supported Enclosures, with Devices, Luminaires, or Lampholders. An enclosure that contains a device(s), other than splicing devices, or supports a luminaire(s), a lampholder, or other equipment and is supported by entering raceways shall not exceed 1650cm3 (100 in.3) in size. It shall have threaded entries or identified hubs. It shall be supported by two or more conduits threaded wrenchtight into the enclosure or hubs. Each conduit shall be secured within 450mm (18 in.) of the enclosure. Exception No. 1: Rigid metal or intermediate metal conduit shall be permitted to support a conduit body of any size, including a conduit body constructed with only one conduit entry, provided the trade size of the conduit body is not larger than the largest trade size of the conduit. Exception No. 2: An unbroken length(s) of rigid or intermediate metal conduit shall be permitted to support a box used for luminaire or lampholder support, or to support a wiring enclosure that is an integral part of a luminaire and used in lieu of a box in accordance with 300.15 (B), where all of the following conditions are met: (a) The conduit is securely fastened at a point so that the length of conduit beyond the last point of conduit support does not exceed 900mm (3 ft.). (b) The unbroken conduit length before the last point of conduit support is 300mm (12 in.) or greater, and that portion of the conduit is securely fastened at some point not less than 300mm (12 in.) from its last point of support. (c) Where accessible to unqualified persons, the luminaire or lampholder, measured to its lowest point, is at least 2.5m (8 ft.) above grade or standing area and at least 900mm (3 ft.) measured horizontally to the 2.5m (8 ft.) elevation from windows, doors, porches, fire escapes, or similar locations. (d) A luminaire supported by a single conduit does not exceed 300mm (12 in.) in any direction from the point of conduit entry. (e) The weight supported by any single conduit does not exceed 9 kg (20 lbs.). 314.23 Supports. Enclosures within the scope of this article shall be supported in accordance with one or more of the provisions in 314.23 (A) through (H). (C) Mounting in Finished Surfaces. An enclosure mounted in a finished surface shall be rigidly secured thereto by clamps, anchors, or fittings identified for the application. (D) Suspended Ceilings. An enclosure mounted to structural or supporting elements of a suspended ceiling shall be not more than 1650cm3 (100 in.3) in size and shall be securely fastened in place in accordance with either (D)(1) or (D)(2). (1) Framing Members. An enclosure shall be fastened to the framing members by mechanical means such as bolts, screws, or rivets, or by the use of clips or other securing means identified for use with the type of ceiling framing member(s) and enclosure(s) employed. The framing members shall be supported in an approved manner and securely fastened to each other and to the building structure. 2) Support Wires. The installation shall comply with the provisions of 300.11 (A). The enclosure shall be secured, using identified methods, to ceiling support wire(s), including any additional support wire(s) installed for ceiling support. Support wire(s) used for enclosure support shall be fastened at each end so as to be taut within the ceiling cavity. (E) Raceway Supported Enclosure, without Devices, Luminaires, or Lampholders. An enclosure that does not contain a device(s), other than splicing devices, or supports a luminaire(s), L.5 StrongHold ™ Codes and Standards Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold L.6 Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) NFPA 70; National Electric Code; 2014 Revision (continued) (f) At the luminaire or lampholder end, the conduit(s) is threaded wrenchtight into the box, conduit body, integral wiring enclosure, or identified hubs. Where a box or conduit body is used for support, the luminaire shall be secured directly to the box or conduit body, or through a threaded conduit nipple not over 75mm (3 in.) long. Type MC cable shall be protected in accordance with 300.4 (A), (C), and (D) where installed through or parallel to framing members. 314.27 Outlet Boxes. (A) Boxes at Luminaire or Lampholder Outlets. Outlet boxes or fittings designed for the support of luminaires and lampholders, and installed as required by 314.23, shall be permitted to support a luminaire or lampholder. (2) Ceiling Outlets. At every outlet used exclusively for lighting, the box shall be designed or installed so that a luminaire or lampholder may be attached. Boxes shall be required to support a luminaire weighing a minimum of 23 kg (50 lbs.). A luminaire that weighs more than 23 kg (50 lbs.) shall be supported independently of the outlet box, unless the outlet box is listed and marked on the interior of the box to indicate the maximum weight the box shall be permitted to support. 320.2 Definition. Armored Cable, Type AC. A fabricated assembly of insulated conductors in a flexible interlocked metallic armor. See 320.100. 320.17 Through or Parallel to Framing Members. Type AC cable shall be protected in accordance with 300.4 (A), (C), and (D) where installed through or parallel to framing members. 320.30 Securing and Supporting. (A) General. Type AC cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings, designed and installed so as not to damage the cable. (B) Securing. Unless otherwise permitted, Type AC cable shall be secured within 300mm (12 in.) of every outlet box, junction box, cabinet, or fitting and at intervals not exceeding 1.4m (4 1⁄2 ft.) where installed on or across framing members. (C) Supporting. Unless otherwise permitted, Type AC cable shall be supported at intervals not exceeding 1.4m (4 1⁄2 ft.). Horizontal runs of Type AC cable installed in wooden or metal framing members or similar supporting means shall be considered supported where such support does not exceed 1.4m (4 1⁄2 ft.) intervals. 330.2 Definition. Metal Clad Cable, Type MC. A factory assembly of one or more insulated circuit conductors with or without optical fiber members enclosed in an armor of interlocking metal tape, or a smooth or corrugated metallic sheath. 330.17 Through or Parallel to Framing Members. L.7 StrongHold ™ Codes and Standards Order number of pieces required, in multiples of Standard Package Quantity. 330.30 Securing and Supporting. (A) General. Type MC cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings or other approved means designed and installed so as not to damage the cable. (B) Securing. Unless otherwise provided, cables shall be secured at intervals not exceeding 1.8m (6 ft.). Cables containing four or fewer conductors sized no larger than 10 AWG shall be secured within 300mm (12 in.) of every box, cabinet, fitting, or other cable termination. In vertical installations, listed cables with ungrounded conductors 250 kcmil and larger shall be permitted to be secured at intervals not exceeding 3m (10 ft.). (C) Supporting. Unless otherwise provided, cables shall be supported at intervals not exceeding 1.8m (6 ft.). Horizontal runs of Type MC cable installed in wooden or metal framing members or similar supporting means shall be considered supported and secured where such support does not exceed 1.8m (6 ft.) intervals. 334.2 Definitions. Nonmetallic-Sheathed Cable. A factory assembly of two or more insulated conductors enclosed within an overall nonmetallic jacket. 334.17 Through or Parallel to Framing Members. Types NM, NMC, or NMS cable shall be protected in accordance with 300.4 where installed through or parallel to framing members. Grommets used as required in 300.4 (B)(1) shall remain in place and be listed for the purpose of cable protection. 334.30 Securing and Supporting. Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable, at intervals not exceeding 1.4m (4 1⁄2 ft.) and within 300mm (12 in.) of every outlet box, junction box, cabinet, or fitting. Flat cables shall not be stapled on edge. Sections of cable protected from physical damage by raceway shall not be required to be secured within the raceway. (A) Horizontal Runs Through Holes and Notches. In other than vertical runs, cables installed in accordance with 300.4 shall be considered to be supported and secured where such support does not exceed 1.4m (4 1⁄2 ft.) intervals and the nonmetallic-sheathed cable is securely fastened in place by an approved means within 300mm (12 in.) of each box, cabinet, conduit body, or other nonmetallic-sheathed cable termination. Informational Note: See 314.17 (C) for support where nonmetallic boxes are used. 342.30 Securing and Supporting. Call 866-405-6654 or visit www.panduit.com/stronghold L.8 Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) NFPA 70; National Electric Code; 2014 Revision (continued) IMC shall be installed as a complete system in accordance with 300.18 and shall be securely fastened in place and supported in accordance with 342.30 (A) and (B). (A) Securely Fastened. IMC shall be secured in accordance with one of the following: (1) IMC shall be securely fastened within 900mm (3 ft.) of each outlet box, junction box, device box, cabinet, conduit body, or other conduit termination. (2) Where structural members do not readily permit fastening within 900mm (3 ft.), fastening shall be permitted to be increased to a distance of 1.5m (5 ft.). (3) Where approved, conduit shall not be required to be securely fastened within 900mm (3 ft.) of the service head for above-theroof termination of a mast. (B) Supports. IMC shall be supported in accordance with one of the following: (1) Conduit shall be supported at intervals not exceeding 3m (10 ft.). (2) The distance between supports for straight runs of conduit shall be permitted in accordance with Table 344.30 (B)(2), provided the conduit is made up with threaded couplings and such supports prevent transmission of stresses to termination where conduit is deflected between supports. place and supported in accordance with 348.30 (A) and (B). (A) Securely Fastened. FMC shall be securely fastened in place by an approved means within 300mm (12 in.) of each box, cabinet, conduit body, or other conduit termination and shall be supported and secured at intervals not to exceed 1.4m (4 1⁄2 ft.) . (B) Supports. Horizontal runs of FMC supported by openings through framing members at intervals not greater than 1.4m (4 1⁄2 ft.) and securely fastened within 300mm (12 in.) of termination points shall be permitted. 344.30 Securing and Supporting. RMC shall be installed as a complete system in accordance with 300.18 and shall be securely fastened in place and supported in accordance with 344.30 (A) and (B). (A) Securely Fastened. RRMC shall be secured in accordance with one of the following: (1) RMC shall be securely fastened within 900mm (3 ft.) of each outlet box, junction box, device box, cabinet, conduit body, or other conduit termination. (2) Fastening shall be permitted to be increased to a distance of 1.5m (5 ft.) where structural members do not readily permit fastening within 900mm (3 ft.). (3) Where approved, conduit shall not be required to be securely fastened within 900mm (3 ft.) of the service head for above-the-roof termination of a mast. (B) Supports. RMC shall be supported in accordance with one of the following: (1) Conduit shall be supported at intervals not exceeding 3m (10 ft.). (2) The distance between supports for straight runs of conduit shall be permitted in accordance with Table 344.30 (B)(2), provided the conduit is made up with threaded couplings and such supports prevent transmission of stresses to termination where conduit is deflected between supports. 348.30 Securing and Supporting. FMC shall be securely fastened in L.9 StrongHold ™ Codes and Standards Order number of pieces required, in multiples of Standard Package Quantity. 358.30 Securing and Supporting. EMT shall be installed as a complete system in accordance with 300.18 and shall be securely fastened in place and supported in accordance with 358.30 (A) and (B). (A) Securely Fastened. EMT shall be securely fastened in place at least every 3m (10 ft.). In addition, each EMT run between termination points shall be securely fastened within 900mm (3 ft.) of each outlet box, junction box, device box, cabinet, conduit body, or other tubing termination. Exception No. 1: Fastening of unbroken lengths shall be permitted to be increased to a distance of 1.5m (5 ft.) where structural members do not readily permit fastening within 900mm (3 ft.). Exception No. 2: For concealed work in finished buildings or prefinished wall panels where such securing is impracticable, unbroken lengths (without coupling) of EMT shall be permitted to be fished. (B) Supports. Horizontal runs of EMT supported by openings through framing members at intervals not greater than 3m (10 ft.) and securely fastened within 900mm (3 ft.) of termination points shall be permitted. 362.2 Definition. Electrical Nonmetallic Tubing (ENT). A nonmetallic, pliable, corrugated raceway of circular cross section with integral or associated couplings, connectors, and fittings for the installation of electrical conductors. ENT is composed of a material that is resistant to moisture and chemical atmospheres and is flame retardant. A pliable raceway is a raceway that can be bent by hand with a reasonable force but without other assistance. 362.30 Securing and Supporting. ENT shall be installed as a complete system in accordance with 300.18 and shall be securely fastened in place and supported in accordance with 362.30 (A) and (B). (A) Securely Fastened. ENT shall be securely fastened at intervals not exceeding 900mm (3 ft.). In addition, ENT shall be securely fastened in place within 900mm (3 ft.) of each outlet box, device box, junction box, cabinet, or fitting where it terminates. Exception No. 1: Lengths not exceeding a distance of 1.8m (6 ft.) from a luminaire terminal connection for tap connections to lighting luminaires Call 866-405-6654 or visit www.panduit.com/stronghold L.10 Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) shall be permitted without being secured. Exception No. 2: Lengths not exceeding 1.8m (6 ft.) from the last point where the raceway is securely fastened for connections within an accessible ceiling to luminaire(s) or other equipment. Exception No. 3: For concealed work in finished buildings or prefinished wall panels where such securing is impracticable, unbroken lengths (without coupling) of ENT shall be permitted to be fished. 410.36 Means of Support. (A) Outlet Boxes. Outlet boxes or fittings installed as required by 314.23 and complying with the provisions of 314.27 (A)(1) and 314.27 (A)(2) shall be permitted to support luminaires. (B) Suspended Ceilings. Framing members of suspended ceiling systems used to support luminaires shall be securely fastened to each other and shall be securely attached to the building structure at appropriate intervals. Luminaires shall be securely fastened to the ceiling framing member by mechanical means such as bolts, screws, or rivets. Listed clips identified for use with the type of ceiling framing member(s) and luminaire(s) shall also be permitted. 410.154 Fastening. Lighting track shall be securely mounted so that each fastening is suitable for supporting the maximum weight of luminaires that can be installed. Unless identified for supports at greater intervals, a single section 1.2m (4 ft.) or shorter in length shall have two supports, and, where installed in a continuous row, each individual section of not more than 1.2m (4 ft.) in length shall have one additional support. 590.4 General. (J) Support. Cable assemblies and flexible cords and cables shall be supported in place at intervals that ensure that they will be protected from physical damage. Support shall be in the form of staples, cable ties, straps, or similar type fittings installed so as not to cause damage. Cable assemblies and flexible cords and cables installed as branch circuits or feeders shall not be installed on the floor or on the ground. Extension cords shall not be required to comply with 590.4(J). Vegetation shall not be used for support of overhead spans of branch circuits or feeders. Exception: For holiday lighting in accordance with 590.3 (B), where the conductors or cables are arranged with strain relief devices, tension take-up devices, or other approved means to avoid damage from the movement of the live vegetation, trees shall be permitted to be used for support of overhead spans of branch-circuit conductors or cables. StrongHold ™ Codes and Standards NFPA 70; National Electric Code; 2014 Revision (continued) 725.24 Mechanical Execution of Work. Class 1, Class 2, and Class 3 circuits shall be installed in a neat and workmanlike manner. Cables and conductors installed exposed on the surface of ceilings and sidewalls shall be supported by the building structure in such a manner that the cable will not be damaged by normal building use. Such cables shall be supported by straps, staples, hangers, cable ties, or similar fittings designed and installed so as not to damage the cable. The installation shall also comply with 300.4 (D). 760.24 Mechanical Execution of Work. (A) General. Fire alarm circuits shall be installed in a neat workmanlike manner. Cables and conductors installed exposed on the surface of ceilings and sidewalls shall be supported by the building structure in such a manner that the cable will not be damaged by normal building use. Such cables shall be supported by straps, staples, cable ties, hangers, or similar fittings designed and installed so as not to damage the cable. The installation shall also comply with 300.4 (D). 800.24 Mechanical Execution of Work. Communications circuits and equipment shall be installed in a neat and workmanlike manner. Cables installed exposed on the surface of ceilings and sidewalls shall be supported by the building structure in such a manner that the cable will not be damaged by normal building use. Such cables shall be secured by hardware, including straps, staples, cable ties, hangers, or similar fittings designed and installed so as not to damage the cable. The installation shall also conform to 300.4 (D) and 300.11. Nonmetallic cable ties and other nonmetallic cable accessories used to secure and support cables in other spaces used for environmental air (plenums) shall be listed as having low smoke and heat release properties. Informational Note No. 1: Accepted industry practices are described in ANSI/NECA/BICSI 568-2006, Standard for Installing Commercial Building Telecommunications Cabling; ANSI/TIA/EIA-568-B.1-2004 — Part 1, General Requirements Commercial Building Telecommunications Cabling Standard; ANSI/TIA-569-B-2004, Commercial Building Standard for Telecommunications Pathways and Spaces; ANSI/TIA-570-B, Residential Telecommunications Infrastructure, and other ANSI-approved installation standards. Informational Note No. 2: See 4.3.11.2.6.5 and 4.3.11.5.5.6 of NFPA 90A-2012, Standard for the Installation of Air-Conditioning and Ventilating Systems, for discrete combustible components installed in accordance with 300.22 (C). 604.7 Installation. Manufactured wiring systems shall be secured and supported in accordance with the applicable cable or conduit article for the cable or conduit type employed. L.11 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold L.12 Codes and Standards Telecommunications Pathways and Spaces; ANSI/TIA-569-C; Revision May, 2012 6.7.6 Low-Voltage Mounting Bracket A low-voltage mounting bracket is similar to a plaster ring and may be used in place of an outlet box where permitted by code. 9.3.2 Telecommunications Pathway Separation From Lighting Balanced twisted-pair cabling should be separated from fluorescent lamps and associated fixtures by a minimum of 125mm (5 in.). 9.4.2.1 Planning The design shall provide a suitable means and method for supporting cables. Cable shall not be laid directly on the ceiling tile or rails. 9.4.2.2 Clearance A minimum of 75mm (3 in.) clear vertical space shall be available above the ceiling tiles for the cabling and pathway. 9.5.4.3 Cable Management Providing physical management for cabling placed within the access floor system lessens the chance of damage or reduced performance over the cable’s life cycle. A method of physical management for major runs of cabling shall be provided. Management systems such as raceways, cable tray, and non-continuous cable supports may be used. 9.7 Non-Continuous Support Non-continuous supports shall be located at intervals not to exceed 1.5m (5 ft.). Non-continuous supports shall be selected to accommodate the immediate and anticipated quantity, weight, and performance requirements of cables. Steel, masonry, independent rods, independent support wires or other structural parts of the building shall be used for cable support attachment points up to the total weight for which the fastener is approved. Rods or wires that are currently employed for other functions (e.g., suspended ceiling grid support) shall not be utilized as attachment points for non-continuous supports. NOTE: A weight of 1 kg (2.2 lbs.) (or 0.7 kg/m [0.5 lb./ft.] with spacing of support wire/rod at 1.5m [5 ft.]) is equivalent to a bundle of sixteen 4-pair 24 AWG UTP cables, including fasteners. 9.8.3.1 Conduit Termination Conduits shall be reamed to eliminate sharp edges. Metallic conduit shall be terminated with an insulated bushing. StrongHold ™ Codes and Standards BICSI TDMM, 12th Edition; 2009 Revision Page 5-1: Introduction Horizontal pathways include: • Continuous pathways (e.g., conduit cable tray and cable matting) used for containment of telecommunications cabling • Non-continuous pathways (e.g., the space between open-top cable supports [J-hooks]) through which cable is placed between physical support or containment components Pages 5-39-5-41: Pathway and Cable Support Every ceiling distribution system must provide proper support for cables from the telecommunications space to the work areas served. Ceiling panels, support channels (T-bars), and suspended ceiling support wires are not proper cabling supports. Ceiling conduits, raceways, cable trays, and cabling must be suspended from or attached to the structural ceiling or walls with hardware or other installation aids specifically designed to support their weight. The pathways must: • Have adequate support to withstand cable pulling • Be installed with at least 75mm (3 in.) of clear vertical space above the ceiling tiles and support channels (T-bars) to ensure accessibility Horizontal pathways or cable should not rest directly on or be supported by: • Ceiling panels • Support channels (T-bars) • Ceiling support wires • Other components of the suspended ceiling It is important to provide sufficient space between the suspended ceiling structure and the telecommunications pathways/cables to install, maneuver, and store ceiling tiles during service. When sufficient space is available above the pathway, up to 150mm (6 in.) should be provided between the suspended ceiling and the cabling pathways. Where building codes permit telecommunications cable to be placed in suspended ceiling spaces without conduit, ceiling zone distribution pathways may consist of: • Cable trays • Open-top supports (e.g., J-hooks) NOTE: J-hooks should be located 1.5m (5 ft.) apart at the maximum to adequately support and distribute the cable’s weight. The manufacturer’s specifications for cable loading should be followed. L.13 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold L.14 Codes and Standards BICSI TDMM, 12th Edition; 2009 Revision (continued) Cable support devices that have narrow surface areas to support the cable laying horizontally inside or on top may have a detrimental effect on the transmissions performance of higher performance cabling systems. If possible, a wider surface area should be chosen to support the cable as a precaution against potential problems. Another precaution would be to reduce the distance between the support devices. Suspended cables must be installed with at least 75mm (3 in.) of clear vertical space above the ceiling tiles and support channels (T-bars). For large quantities of cables (50 or more) that converge at the ER, TR, and other areas, provide cable trays or other special supports that are specifically designed to support the required cable weight and volume. Page 5-57: Telecommunications Outlets/Connectors Telecommunications outlet/connector boxes must be used in fire-rated wall installations and must be firestopped appropriately. Low-voltage mounting brackets (e.g., also known as mud ring, plaster ring, square-drawn cover, and box eliminator) may be used where the wall is not fire rated, and are typically used for work associated with MACs. Telecommunications outlet/connector boxes installed in dry wall, plaster, or concrete block wall are available in an array of shapes and sizes. The size of each telecommunications outlet/connector box must be of a size that is adequate to accommodate the type and density of cabling to be installed. Telecommunications outlet/connector boxes should not be placed back to back to serve adjacent rooms. This can compromise the effectiveness of the wall as a sound barrier and as a firestop. StrongHold ™ Codes and Standards J-ProTM Cable Support System – Frequently Asked Questions Question: What references define how and where J-hooks are used? Answer: J-hooks are a horizontal pathway promoted in the BICSI® TDM manual as a means to route cable bundles (see catalog pages O.14 – O.15). Furthermore, the TIA-569-C standard promotes non-continuous supports as a means to route cable bundles as well (see catalog page O.13). According to Underwriters Laboratories Inc. (UL), the portion of the NEC® that defines the requirements of this cabling pathway is found in Section 300.22 of the NEC (see catalog pages O.2 – O.4). Question: What is the difference between plenum space and air handling space? Answer: The industry-wide confusion regarding the definition of a plenum space verses an air handling space is very common as the area above a drop ceiling is mistakenly referred to as a plenum. Simply stated, the NEC defines a plenum area as, “a compartment or chamber to which one or more air ducts are connected and that forms part of the air distribution system.” They also reference, “the space over a hung ceiling used for environmental air-handling purposes,” and, “areas beneath raised floors for information technology equipment,” as air handling space (NEC pg. 70-144 and 70-145; see catalog pages O.2 – O.4). Often, the NEC definition of these terms differs from their common use in the industry – however, UL is compatible with the NEC terms and definitions. Therefore, the space above a hung (or drop/suspended) ceiling utilized as an air return to the HVAC unit is considered an air handling space. Additionally, the area below a raised floor used to supply conditioned air is also considered an air handling space. Question: Is the J-ProTM Cable Support System approved by UL for use in air handling spaces in the United States? Answer: Yes, during the development of the J-ProTM Cable Support System, Panduit coordinated testing and evaluation with UL for approval of the following statement on all the J-ProTM Cable Support System products to reduce confusion in the market: “Suitable for use in air handling spaces in accordance with Section 300.22 (C) and (D) of the NEC….” This statement is engraved and is visible on the side or bottom of each part. According to this phrase, the J-ProTM Cable L.15 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold L.16 Codes and Standards J-ProTM Cable Support System – Frequently Asked Questions (continued) Support System can be utilized in the area above the suspended ceiling (300.22 [C]) or below a raised floor (300.22 [D]), but it cannot be utilized within ductwork (300.22 [A] and [B]) (see catalog pages O.2 – O.4). Approval to use J-ProTM Cable Support System above the suspended ceiling and below the raised floor was a result of completing/passing testing of the J-ProTM Cable Support System per the UL standard UL2043, Fire Test for Visible Heat and Smoke Release for Discrete Products and their Accessories Installed in Air-Handling Spaces. This test requires product to meet certain criteria for heat release and smoke density and the values measured correlate back to the maximum flame spread and smoke index of the mechanical code. The basic standard used to investigate products in this category is ANSI/UL 1565, “Positioning Devices”. The J-ProTM Cable Support System product line is UL listed within UL file number E136577. Question: Is the J-ProTM Cable Support System approved by Underwriters’ Laboratories of Canada (ULC) for use in air handling spaces? Answer: Yes, for applications within Canada, the J-ProTM Cable Support System was tested and evaluated by ULC for approval of the following statement, “In accordance with CAN/ULC S102.2 in single units or pairs. 4-foot minimum spacing, FSR = 0, SDC = 35.” This statement is engraved and visible on the side or bottom of each part. According to this phrase, the J-ProTM Cable Support System is approved for the same air handling spaces as defined by the NEC Article 300.22 (C) and (D) (above the suspended ceiling or below a raised floor) and meets the S102.2 (Standard Method of Test for Surface Burning Characteristics of Floor Coverings, and Miscellaneous Material and Assemblies) requirements as stated in the National Building Code of Canada. The J-ProTM Cable Support System product line is ULC listed within ULC file number R21673. StrongHold ™ Codes and Standards UL File E136577 Volume 2, Section 2 Page 1 ULC File R21673 Volume 1 Description Product Covered: USL, CNL – Positioning Devices – Model JP2, JP4, JP75, JP131 General Description: USL, CNL – Indicates that the products have been evaluated in accordance with the requirements in UL 1565 and CAN/CSA C22.2 No. 18.5-02 Standards for Positioning Devices. These devices are a J-ProTM J-hook, and are used in applications where zone conduit, cable trays, or ladder racks are not available or applicable. The J-ProTM J-hook contains a family of parts. This system has several other brackets and/or components, manufactured from a high-carbon plated steel, riveted to the JP2, JP4, JP75, and JP131 for a variety of applications. Table 1 Family of Part Numbers J-ProTM Cable Support System Description JP2 J-ProTM J-hook Ratings: These devices are rated 60°C, for indoor use, suitable for use in air handling spaces in accordance with Sec. 300.22 (C) and (D) of the National Electrical Code in single units or pairs, and 30 lb. maximum load rating. Table 3 Family of Part Numbers J-ProTM Cable Support System Description JP4 J-ProTM J-hook Ratings: These devices are rated 60°C, for indoor use, suitable for use in air handling spaces in accordance with Sec. 300.22 (C) and (D) of the National Electrical Code, and 100 lb. maximum load rating in single unit configuration only. L.17 Order number of pieces required, in multiples of Standard Package Quantity. Call 866-405-6654 or visit www.panduit.com/stronghold L.18 Codes and Standards Part Number Index B Table 4 Family of Part Numbers J-ProTM Cable Support System Description JP75 J-ProTM J-hook Ratings: These devices are rated 60°C, for indoor use, suitable for use in air handling spaces in accordance with Sec. 300.22 (C) and (D) of the National Electrical Code in single units or pairs, and 15 lb. maximum load rating. Table 5 Family of Part Numbers J-ProTM Cable Support System Description JP131 J-ProTM J-hook Ratings: These devices are rated 60°C, for indoor use, suitable for use in air handling spaces in accordance with Sec. 300.22 (C) and (D) of the National Electrical Code in single units or pairs, and 20 lb. maximum load rating. Scope for UL 1565 Positioning Devices 1 Scope 1:1 This standard applies to those metallic and nonmetallic devices used for positioning – which may include bundling and securing – or to a limited extent supporting cable, wire, conduit, or tubing of a wiring system in electrical installations, to reduce the risk of fire, electric shock, or injury to persons. This standard applies to, but is not limited to, cable ties, cable tie mounting blocks, cable clamps, cable and conduit clips, and non-raceway ducts. L.19 Order number of pieces required, in multiples of Standard Package Quantity. BR-1.5-PAF............................H.64 BR-1.5-SN..............................H.64 BR-1.5-TW.............................H.64 BR-1.25-1/4-20......................H.64 BR-1.25-10-24.......................H.64 BR-1.25-14WS.......................H.64 BR-2.0-1/4-20........................H.64 BR-2.0-10-24.........................H.64 BR-2.0-14W...........................H.64 BR-2.0-PAF............................H.64 BR-2.0-SN..............................H.64 BR-2.0-TW.............................H.64 BR-4.0-1/4-20........................H.64 BR-.50-10-24.........................H.64 BR-.75-10-24.........................H.64 C CSM-1.25-C...........................H.48 D DS1........................................... I.3 DS5........................................... I.3 E E10-6FB-Q............................... E.3 E10-6LFB-Q............................. E.4 E10-6RB-Q............................... E.3 E10-8FB-Q............................... E.3 E10-8LFB-Q............................. E.4 E10-8RB-Q............................... E.3 E10-10FB-Q............................. E.3 E10-10LFB-Q........................... E.4 E10-10RB-Q............................. E.3 E10-14FB-Q............................. E.3 E10-14LFB-Q........................... E.4 E10-14RB-Q............................. E.3 E14-4RB-Q*.............................. E.3 E14-6FB-Q*.............................. E.3 E14-6LFB-Q*............................ E.4 E14-6RB-Q*.............................. E.3 E14-8FB-Q*.............................. E.3 E14-8LFB-Q*............................ E.4 E14-8RB-Q*.............................. E.3 E14-10FB-Q*............................ E.3 E14-10LFB-Q*.......................... E.4 E14-10RB-Q*............................ E.3 E18-4RB-Q*.............................. E.3 E18-6FB-Q*.............................. E.3 E18-6LFB-Q*............................ E.4 E18-6RB-Q*.............................. E.3 E18-8FB-Q*.............................. E.3 E18-8LFB-Q*............................ E.4 E18-8RB-Q*.............................. E.3 E18-10FB-Q*............................ E.3 E18-10LFB-Q*.......................... E.4 E18-10RB-Q*............................ E.3 EBNF14-4FIB-Q........................ E.6 EBNF14-4FIM-Q....................... E.6 EBNF18-4FIB-Q........................ E.6 EBNF18-4FIM-Q....................... E.6 EBV14-4B-Q............................. E.6 EBV14-4MB-Q.......................... E.6 EBV18-4B-Q............................. E.6 EBV18-4MB-Q.......................... E.6 ED10-250M-Q.......................... E.5 ED14-188-Q*............................ E.5 ED14-250MB-Q*...................... E.5 ED14-250-Q*............................ E.5 ED18-188-Q*............................ E.5 ED18-250MB-Q*...................... E.5 ED18-250-Q*............................ E.5 EDNF10-250FI-Q...................... E.4 EDNF14-187MB-Q.................... E.5 EDNF14-188FIB-Q*................... E.4 EDNF14-250FIB-Q*................... E.4 EDNF18-187MB-Q.................... E.5 EDNF18-188FIB-Q*................... E.4 EDNF18-250FIB-Q*................... E.4 EDNF10250FIMB-Q................... E.5 EDNF14250FIMB-Q*................. E.5 EDNF18250FIMB-Q*................. E.5 EDV10-11MB-Q........................ E.8 EDV10-250FIB-Q...................... E.5 EDV10-250M-Q........................ E.5 EDV10-250P-Q......................... E.6 EDV10-250-Q........................... E.5 EDV14-87MB-Q........................ E.8 EDV14-187MB-Q...................... E.5 EDV14-188B-Q*....................... E.5 EDV14-250B-Q*....................... E.5 EDV14-250FIB-Q...................... E.5 EDV14-250M-Q*....................... E.5 EDV14-250P-Q*........................ E.6 EDV18-87MB-Q........................ E.8 EDV18-187MB-Q...................... E.5 EDV18-188B-Q*....................... E.5 EDV18-250B-Q*....................... E.5 EDV18-250FIB-Q...................... E.5 EDV18-250M-Q*....................... E.5 EDV18-250P-Q*........................ E.6 EJN218-216-Q*........................ E.8 EJN314-412-Q......................... E.8 EJN418-212-Q......................... E.8 EQSP10-18D-Q......................... E.7 EQSP10-Q................................ E.7 EQSP14D-Q*............................. E.7 EQSP14-Q................................ E.7 EQSP18D-Q.............................. E.7 EQSP18-Q................................ E.7 ES10B-Q................................... E.6 ES14B-Q*................................. E.6 ES18B-Q*................................. E.6 ESV6-ESV8-Q........................... E.7 ESV8-ESV10-Q......................... E.7 ESV8-ESV14-Q......................... E.7 ESV10BX-Q............................... E.6 ESV10-ESV14-Q....................... E.7 ESV10-ESV18-Q....................... E.7 ESV14BX-Q*............................. E.6 ESV14-ESV18-Q....................... E.7 ESV18BX-Q*............................. E.6 EV6-10R-Q............................... E.2 EV6-12R-Q............................... E.2 EV6-38R-Q............................... E.2 EV6-56R-Q............................... E.2 EV8-8R-Q................................. E.2 EV8-12R-Q............................... E.2 EV8-14R-Q............................... E.2 EV8-38R-Q............................... E.2 EV8-56R-Q............................... E.2 EV10-6FB-Q............................. E.3 EV10-6LFB-Q............................ E.4 EV10-6RB-Q............................. E.2 EV10-8FB-Q............................. E.3 EV10-8FNB-Q........................... E.4 EV10-8LFB-Q............................ E.4 Call 866-405-6654 or visit www.panduit.com/stronghold M.1 Part Number Index EV10-8RB-Q............................. E.2 EV10-10FB-Q........................... E.3 EV10-10FNB-Q......................... E.4 EV10-10LFB-Q.......................... E.4 EV10-10RB-Q........................... E.2 EV10-12RB-Q........................... E.2 EV10-14FB-Q........................... E.3 EV10-14LFB-Q.......................... E.4 EV10-14RB-Q........................... E.2 EV10-38RB-Q........................... E.2 EV10-56FB-Q........................... E.3 EV10-56RB-Q........................... E.2 EV10-P55-Q............................. E.7 EV14-6FB-Q*............................ E.3 EV14-6FNB-Q........................... E.4 EV14-6LFB-Q*.......................... E.4 EV14-6RB-Q*............................ E.2 EV14-8FB-Q*............................ E.3 EV14-8FNB-Q........................... E.4 EV14-8LFB-Q*.......................... E.4 EV14-8RB-Q*............................ E.2 EV14-10FB-Q*.......................... E.3 EV14-10FNB-Q......................... E.4 EV14-10LFB-Q*........................ E.4 EV14-10RB-Q*.......................... E.2 EV14-14FB-Q........................... E.3 EV14-14RB-Q*.......................... E.2 EV14-38RB-Q........................... E.2 EV14-56RB-Q*.......................... E.2 EV14-P47B-Q*.......................... E.7 EV18-6FB-Q*............................ E.3 EV18-6LFB-Q*.......................... E.4 EV18-6RB-Q*............................ E.2 EV18-8FB-Q*............................ E.3 EV18-8LFB-Q*.......................... E.4 EV18-8RB-Q*............................ E.2 EV18-10FB-Q*.......................... E.3 EV18-10LFB-Q*........................ E.4 EV18-10RB-Q*.......................... E.2 EV18-14FB-Q........................... E.3 EV18-14RB-Q*.......................... E.2 EV18-56RB-Q*.......................... E.2 EV18-P47B-Q*.......................... E.7 G GSC10-32-38-C........................F.2 GSH10-32-38-C........................F.2 H HLSP1.5S-X0..........................H.61 HLSP1.5S-X12........................H.61 HLSP3S-X0.............................H.61 HLSP3S-X12...........................H.61 HLSP5S-X0.............................H.61 HLSP5S-X12...........................H.61 HLTP2I-X0...............................H.61 HLTP2I-X12.............................H.61 HLTP3I-X0...............................H.61 HLTP3I-X12.............................H.61 HLTT1.5S-Q20........................H.62 HT2-BLU...................................D.4 HT2-GRN..................................D.4 HT2-ORN..................................D.4 HT2-RED..................................D.4 HT2S-BLK-YEL..........................D.4 HT2S-RED-WHT........................D.4 HT2-WHT..................................D.4 HT2-YEL...................................D.4 M.2 HT3S-BLK-YEL..........................D.4 HT3S-RED-WHT........................D.4 HTB3-C-M................................D.3 HTB3-DNE-M............................D.3 HTB3-HV-M..............................D.3 HTDU3B-W...............................D.3 HTDU3G-S................................D.3 HTDU3O-T................................D.3 HTDU3R-E................................D.3 HTDU30-FO..............................D.3 HTDU60-FO..............................D.3 HTU3G-T-M..............................D.2 HTU3O-FO-M............................D.2 HTU3O-T-M..............................D.2 HTU3R-E-M..............................D.2 HTU3Y-EF.................................D.2 HTU3Y-E-M...............................D.2 HTU6O-FO................................D.2 HTU6R-E...................................D.2 HTU6Y-E...................................D.2 HTU6Y-G...................................D.2 HTU60-T...................................D.2 HTU60-TV.................................D.2 I IMLT25S-C................................B.4 IMLT25S-C6L............................B.4 IMLT51H-L................................B.4 IMLT51H-L6L............................B.4 IMLT51S-C................................B.4 IMLT51S-C6L............................B.4 IMLT69H-L................................B.4 IMLT69H-L6L............................B.4 IMLT69S-C................................B.4 IMLT69S-C6L............................B.4 IMLT102H-L..............................B.4 IMLT102H-L6L..........................B.4 IMLT102S-C..............................B.4 IMLT102S-C6L..........................B.4 IMLT152H-L..............................B.4 IMLT152H-L6L..........................B.4 IMLT152S-C..............................B.4 IMLT152S-C6L..........................B.4 IMLT203H-L..............................B.4 IMLT203H-L6L..........................B.4 IMLT203S-C..............................B.4 IMLT203S-C6L..........................B.4 IMLT254H-L..............................B.4 IMLT254H-L6L..........................B.4 IMLT254S-C..............................B.4 IMLT254S-C6L..........................B.4 IMLT304H-Q.............................B.4 IMLT304H-Q6L.........................B.4 IMLT304S-Q.............................B.4 IMLT304S-Q6L..........................B.4 IMLT355H-Q.............................B.4 IMLT355H-Q6L.........................B.4 IMLT355S-Q.............................B.4 IMLT355S-Q6L..........................B.4 IMLT380S-Q.............................B.4 IMLT380S-Q6L..........................B.4 IMLTFC38H-C6L........................B.6 IMLTFC38S-C6L........................B.6 IMLTFC51H-L6L........................B.6 IMLTFC51S-C6L........................B.6 IMLTFC64H-C6L........................B.6 IMLTFC64S-C6L........................B.6 IMLTFC69H-L6L........................B.6 IMLTFC86H-C6L........................B.6 Order number of pieces required, in multiples of Standard Package Quantity. StrongHold ™ Part Number Index IMLTFC86S-C6L........................B.6 IMLTFC102H-L6L......................B.6 IMLTFC102S-C6L......................B.6 IMLTFC137H-C6L......................B.6 IMLTFC137S-C6L......................B.6 IMLTFC152H-L6L......................B.6 IMLTFC152S-C6L......................B.6 IMLTFC203H-L6L......................B.6 IMLTFC203S-C6L......................B.6 IMS9.5T35-QR6L......................B.8 IMS12T35-QR6L.......................B.8 IMS16T35-QR6L.......................B.8 IMS19T75-QR6L.......................B.8 IMSBE19-C6L...........................B.8 IMSBL9.5-C6L..........................B.8 IMSBL12-C6L...........................B.8 IMSBL16-C6L...........................B.8 IMSP9.5T35-QR6L....................B.8 IMSP12T35-QR6L.....................B.8 IMSP16T35-QR6L.....................B.8 J JMCB-X..................................H.60 JMCMB25-1-X........................H.60 JMCMB25-3-X........................H.60 JMDWB-1-X...........................H.60 JMDWB-3-X...........................H.60 JMJH2W-X20.........................H.60 JMJH2-X20............................H.60 JMSBCB87-1-X......................H.60 JMSBCB87-3-X......................H.60 JMTRB38-1-X.........................H.60 JMTRB38-3-X.........................H.60 JP2CMB-L20..........................H.53 JP2CP-L20.............................H.53 JP2DW-L20............................H.53 JP2HBC25RB-L20...................H.53 JP2HBC50RB-L20...................H.53 JP2HBC75RB-L20...................H.53 JP2SBC50-L20.......................H.53 JP2SBC50RB-L20...................H.53 JP2SBC87-L20.......................H.53 JP2SBC87RB-L20...................H.53 JP2UF100-L20.......................H.53 JP2W-L20..............................H.53 JP2WP2B-L20........................H.53 JP2ZP-L20.............................H.53 JP4CMB-X20..........................H.54 JP4CP-X20.............................H.54 JP4HBC25RB-X20..................H.54 JP4HBC50RB-X20..................H.54 JP4HBC75RB-X20..................H.54 JP4SBC50RB-X20...................H.54 JP4SBC50-X20.......................H.54 JP4SBC87RB-X20...................H.54 JP4SBC87-X20.......................H.54 JP4UF100-X20.......................H.54 JP4WP2B-X20........................H.54 JP4W-X20..............................H.54 JP4ZP-X20.............................H.54 JP75CMB-L20........................H.51 JP75CP-L20...........................H.51 JP75DW-L20..........................H.51 JP75HBC25RB-L20.................H.51 JP75HBC50RB-L20.................H.51 JP75HBC75RB-L20.................H.51 JP75SBC50-L20.....................H.51 JP75SBC50RB-L20.................H.51 JP75SBC87-L20.....................H.51 JP75SBC87RB-L20.................H.51 JP75UF100-L20.....................H.51 JP75W-L20............................H.51 JP75WP2B-L20......................H.51 JP75ZP-L20...........................H.51 JP131CMB-L20......................H.52 JP131CP-L20.........................H.52 JP131DW-L20........................H.52 JP131HBC25RBL20................H.52 JP131HBC50RBL20................H.52 JP131HBC75RBL20................H.52 JP131SBC50-L20...................H.52 JP131SBC50RBL20................H.52 JP131SBC87-L20...................H.52 JP131SBC87RBL20................H.52 JP131UF100-L20...................H.52 JP131W-L20..........................H.52 JP131WP2B-L20....................H.52 JP131ZP-L20.........................H.52 K KWP3Y................................... J.13 KWPY..................................... J.13 L LV-S-1G..................................H.66 LV-S-2G..................................H.66 LV-W-1G.................................H.66 LV-W-2G.................................H.66 M MC/AC....................................H.44 MSG-1.3-C....................H.47, H.49 MSGV-1.3-C...........................H.47 MSPT-1.3...............................H.49 N NK^HSFIWY.............................. J.9 NK2HSRFIW............................ J.10 NK2RMFIW.....................J.12, J.14 NK4HSRFIW............................ J.10 NK4MFIW.......................J.12, J.14 NK4RMFIW.....................J.12, J.14 NK4VSF.................................... J.9 NK4VSRFIW............................ J.10 NK5EPC^*Y.............................. J.4 NK5EPPG12WY......................... J.6 NK5EPPG24Y............................ J.6 NK5EPPG48Y............................ J.6 NK6PC^*Y................................ J.4 NK6PPG12WY........................... J.6 NK6PPG24Y.............................. J.6 NK6PPG48Y.............................. J.6 NK6X88MIW.......................J.2, J.4 NK6X88MIW-Q.......................... J.2 NK6XPPG24Y............................ J.5 NK6XPPG48Y......................J.5, J.7 NK688MIW............................... J.3 NK688MIW-Q............................ J.3 NK2106MFIW.................J.12, J.14 NK4106MFIW.................J.12, J.14 NKA5EPPG24Y.......................... J.6 NKA5EPPG48Y.......................... J.6 NKA6PPG24Y............................ J.6 NKA6PPG48Y............................ J.6 NKA6XPPG24Y.......................... J.5 Call 866-405-6654 or visit www.panduit.com/stronghold M.3 Part Number Index NKA6XPPG48Y.......................... J.5 NKBMIW-X.............................. J.15 NKBNCMIWY........................... J.15 NKF^^S................................... J.9 NKFIW.................................... J.15 NK**FIWY.................................. J.9 NK*FNIW................................... J.9 NKFP12W................................. J.7 NKFP24Y.................................. J.7 NKFP48Y.................................. J.7 NKHDMIIW.............................. J.15 NKP5E88MIW........................... J.3 NKP5E88MIW-Q........................ J.3 NKPP24FMY............................. J.7 NKPP48FMY............................. J.7 NKPPA24FMY........................... J.7 NKPPA48FMY........................... J.7 NKSPB.................................... J.16 NKUSBAAIW............................ J.15 Non-metallic...........................H.44 P P4ACS....................................H.71 P4G16....................................H.74 P4G162..................................H.75 P4H24....................................H.21 P4H58....................................H.21 P4H912..................................H.21 P4TI........................................H.78 P4TI24....................................H.26 P4TI912..................................H.26 P4TIB......................................H.32 P4TIO.....................................H.32 P4WN.....................................H.80 P4Z34*...................................H.10 P4Z348P.................................H.10 P4Z3412P...............................H.10 P4Z3416M..............................H.10 P4Z3416P...............................H.10 P4Z34812M............................H.10 P6A........................................H.79 P6A24....................................H.26 P6A58....................................H.26 P6A912..................................H.26 P6AO......................................H.32 P6M..........................................H.1 P6M24......................................H.3 P6M24SM.................................H.4 P6M58......................................H.3 P6M58SM.................................H.4 P6M912....................................H.3 P6M912SM...............................H.4 P6MATA..................................H.69 P6MATS..................................H.70 P6MB18.................................H.14 P6MB18A...............................H.14 P6MF......................................H.38 P6TA24...................................H.26 P6TA58...................................H.26 P6TB......................................H.32 P6TI........................................H.78 P6TIB......................................H.32 P6TIO.....................................H.32 P6TO......................................H.32 P6Z34.....................................H.10 P8P..........................................H.2 P8P8P....................................H.11 P8P12P..................................H.11 P8P16P..................................H.11 M.4 P8P24......................................H.7 P8P24SM.................................H.7 P8P58......................................H.7 P8P58SM.................................H.7 P8P912....................................H.7 P8P912SM...............................H.7 P8PATA...................................H.69 P8PATS...................................H.70 P8PF.......................................H.38 P12P........................................H.2 P12P12P................................H.11 P12P16P................................H.11 P12P24....................................H.7 P12P24SM...............................H.7 P12P58....................................H.7 P12P58SM...............................H.7 P12P912..................................H.7 P12P912SM.............................H.7 P12PATA.................................H.69 P12PATS.................................H.70 P12PF.....................................H.38 P16M........................................H.1 P16M24....................................H.3 P16M24SM...............................H.4 P16M58....................................H.3 P16M58SM...............................H.4 P16M912..................................H.3 P16M912SM.............................H.4 P16MATA................................H.69 P16MATS................................H.70 P16MB18...............................H.15 P16MB18A.............................H.15 P16MF....................................H.38 P16P........................................H.2 P16P16P................................H.11 P16P24....................................H.7 P16P24SM...............................H.7 P16P58....................................H.7 P16P58SM...............................H.7 P16P912..................................H.7 P16P912SM.............................H.7 P16PATA.................................H.69 P16PATS.................................H.70 P16PF.....................................H.38 P20M........................................H.1 P20M24....................................H.3 P20M24SM...............................H.4 P20M58....................................H.3 P20M58SM...............................H.4 P20M912..................................H.3 P20M912SM.............................H.4 P24M........................................H.1 P24M24....................................H.3 P24M24SM...............................H.4 P24M58....................................H.3 P24M58SM...............................H.4 P24M912..................................H.3 P24M912SM.............................H.4 P32M........................................H.1 P32M24....................................H.3 P32M24SM...............................H.4 P32M58....................................H.3 P32M58SM...............................H.4 P32M912..................................H.3 P32M912SM.............................H.4 P122......................................H.28 P123......................................H.28 P166M....................................H.11 P304B2..................................H.35 P350......................................H.39 Order number of pieces required, in multiples of Standard Package Quantity. StrongHold ™ Part Number Index P449......................................H.17 P512......................................H.72 P512A....................................H.72 P512HDK................................H.73 P512HDT................................H.73 P515A....................................H.68 P520......................................H.74 P766......................................H.40 P766PMD...............................H.40 P812M......................................H.1 P812M4I**................................H.1 P812M24..................................H.3 P812M24SM.............................H.4 P812M58..................................H.3 P812M58SM.............................H.4 P812M912................................H.3 P812M912SM...........................H.4 P812MATA..............................H.69 P812MATS..............................H.70 P812MB18.............................H.14 P812MB18A...........................H.14 P812MB18S...........................H.15 P812MB1824.........................H.14 P812MF..................................H.38 P1224TI..................................H.31 P1226T...................................H.31 P1226TI..................................H.31 P1236M..................................H.30 P1238P..................................H.30 P1616M..................................H.11 P1620M..................................H.11 P1624M..................................H.11 P3508P..................................H.39 P12312P................................H.30 P12316M................................H.30 P12316P................................H.30 P12320M................................H.30 P16812M................................H.11 P35012P................................H.39 P35016M................................H.39 P35016P................................H.39 P123812M..............................H.30 P350812M..............................H.39 PAF14.....................................H.27 PAO........................................H.81 PAOL8P..................................H.19 PAOL12P................................H.19 PAOL16P................................H.19 PATA4I....................................H.68 PBC........................................H.20 PBC*.......................................H.20 PBC8P....................................H.24 PBC8PSM...............................H.24 PBC12P..................................H.24 PBC12PSM.............................H.24 PBC16M.................................H.24 PBC16MSM............................H.24 PBC16P..................................H.24 PBC16PSM.............................H.24 PBC20M.................................H.24 PBC20MSM............................H.24 PBC24M.................................H.24 PBC24MSM............................H.24 PBC32M.................................H.24 PBC32MSM............................H.24 PBC200..................................H.20 PBC200CD1B..........................H.25 PBC200CD2.5B.......................H.25 PBC200CD2B..........................H.25 PBC200CD3B..........................H.25 PBC200CD4B..........................H.25 PBC200CD5B..........................H.25 PBC400..................................H.20 PBC812M...............................H.24 PBC812MSM..........................H.24 PCATHBA................................H.55 PCD0B......................................H.2 PCD1B......................................H.2 PCD2.5B...................................H.2 PCD2B......................................H.2 PCD3B......................................H.2 PCD4B......................................H.2 PCD5B......................................H.2 PCD6B......................................H.2 PCD7B......................................H.2 PCD8B......................................H.2 PCD9B......................................H.2 PCJ6.......................................H.44 PCMB-1....................................G.2 PCMB-2....................................G.2 PCMB-3....................................G.2 PCMB-4....................................G.2 PCMB-5....................................G.2 PCMB-6....................................G.2 PCMB-7....................................G.2 PCMB-8....................................G.2 PCMB-9....................................G.2 PCMB-11..................................G.2 PCMB-12..................................G.2 PCMB-13..................................G.2 PCMB-14..................................G.2 PCMB-15..................................G.2 PCMB-16..................................G.2 PCMB-25..................................G.2 PCNB8P..................................H.19 PCNB12P................................H.19 PCNB812M.............................H.19 PCS16....................................H.35 PCS812D................................H.35 PDS12A..................................H.67 PEC311..................................H.76 PEC3114Z34..........................H.76 PFB6M....................................H.46 PFB8P....................................H.46 PFB12P..................................H.46 PFB812M................................H.46 PFBS18....................................H.6 PFMBS18...............................H.43 PFXC20..................................H.45 PH4........................................H.34 PH6........................................H.34 PH23......................................H.34 PIDS.......................................H.71 PJ1A4.....................................H.40 PJ1A6.....................................H.40 PJ1A25...................................H.40 PJ1A35...................................H.40 PK8..........................................H.9 PK12........................................H.9 PK16*.......................................H.9 PK20*.......................................H.9 PKX*.........................................H.8 PM24......................................H.22 PM24S...................................H.22 PM58......................................H.22 PM58S...................................H.22 PM912....................................H.22 PM912S.................................H.22 PMCS50.................................H.18 PMCS100...............................H.18 Call 866-405-6654 or visit www.panduit.com/stronghold M.5 Part Number Index PMCS101...............................H.18 PMEB1...................................H.34 PMF250..................................H.37 PMF375..................................H.37 PMF500..................................H.37 PMF625..................................H.37 PMF750..................................H.37 PMFO.....................................H.36 PMFS......................................H.36 PMSF......................................H.36 PMSR24.................................H.33 PMSR58.................................H.33 PMSR912...............................H.33 PMSS24.................................H.33 PMSS58.................................H.33 PMSS912...............................H.33 PPT16.....................................H.75 PRBS16..................................H.42 PRBS24..................................H.42 PRLC......................................H.67 PSC2A....................................H.16 PSC2B....................................H.16 PSC2C....................................H.16 PSC2D....................................H.16 PSC2E....................................H.16 PSC2F....................................H.16 PSC2G....................................H.16 PSC4A....................................H.16 PSC4B....................................H.16 PSC4C....................................H.16 PSC4D....................................H.16 PSC4E....................................H.16 PSC4F....................................H.16 PSC4G....................................H.16 PSC8A....................................H.16 PSC8B....................................H.16 PSC8C....................................H.16 PSC8D....................................H.16 PSC8E....................................H.16 PSC8F....................................H.16 PSC8G....................................H.16 PSCB-3Y...................................G.3 PSCB-3YELY*............................G.3 PSCB-5Y...................................G.3 PSCB-6Y...................................G.3 PSCB-12Y.................................G.3 PSCB-13Y.................................G.3 PSCB-16Y.................................G.3 PSCH6B..................................H.12 PSCH8B..................................H.12 PSCH12B................................H.12 PSCH16B................................H.12 PSCH20B................................H.12 PSCH24B................................H.12 PSCH32B................................H.12 PSCH40B................................H.12 PSCH48B................................H.12 PSCH56B................................H.12 PSCH64B................................H.12 PSCH72B................................H.12 PSGB16A..................................H.5 PSGB24A..................................H.5 PSK85I...................................H.13 PSK125I.................................H.13 PSK165I.................................H.13 PSK205..................................H.13 PSK245I.................................H.13 PSK325I.................................H.13 PSK405I.................................H.13 PSK485I.................................H.13 M.6 PSK565I.................................H.13 PSK645I.................................H.13 PTSGB16................................H.41 PTSGB24................................H.41 PVF14.....................................H.27 PVF144TI................................H.29 PVF146T.................................H.29 PVF146TI................................H.29 PWMX3...................................H.17 PWMX6...................................H.17 S S4-18-C................................... A.4 S4-18-C0................................. A.4 S4-18-M................................... A.4 S4-18-M0................................. A.4 S5-50-C................................... A.6 S5-50-C0................................. A.6 S5-50-M................................... A.6 S5-50-M0................................. A.6 S6-18-C................................... A.4 S6-18-C0................................. A.4 S6-18-M................................... A.4 S6-18-M0................................. A.4 S6-40-C................................... A.4 S6-40-C0................................. A.4 S6-40-M................................... A.4 S6-40-M0................................. A.4 S6-50-C................................... A.6 S6-50-C0................................. A.6 S6-50-M................................... A.6 S6-50-M0................................. A.6 S7-50-C................................... A.6 S7-50-C0................................. A.6 S7-50-C2................................. A.6 S7-50-M................................... A.6 S7-50-M0................................. A.6 S8-18-C................................... A.4 S8-18-C0................................. A.4 S8-18-M................................... A.4 S8-18-M0................................. A.4 S8-40-C................................... A.4 S8-40-C0................................. A.4 S8-40-M................................... A.4 S8-40-M0................................. A.4 S8-50-C................................... A.6 S8-50-C0................................. A.6 S8-50-M................................... A.6 S8-50-M0................................. A.6 S10-50-C................................. A.6 S10-50-C0............................... A.6 S12-40-C................................. A.4 S12-40-C0............................... A.4 S12-40-M................................. A.4 S12-40-M0............................... A.4 S12-50-C................................. A.6 S12-50-C0............................... A.6 S12-50-C2............................... A.6 S12-50-M................................. A.6 S12-50-M0............................... A.6 S14-120-L.............................. A.10 S14-120-L0............................ A.10 S14-120-TL............................ A.10 S14-120-TL0.......................... A.10 S15-40-C................................. A.4 S15-40-C0............................... A.4 S15-50-C................................. A.6 S15-50-C0............................... A.8 S15-50-C2............................... A.8 Order number of pieces required, in multiples of Standard Package Quantity. StrongHold ™ Part Number Index S15-50-M................................. A.8 S15-50-M0............................... A.8 S17-50-C................................. A.8 S17-50-C0............................... A.8 S17-50-M................................. A.8 S17-50-M0............................... A.8 S18-120-L.............................. A.10 S18-120-L0............................ A.10 S18-175-L.............................. A.12 S18-175-L0............................ A.12 S21-50-C................................. A.8 S21-50-C0............................... A.8 S21-50-M................................. A.8 S21-50-M0............................... A.8 S21-120-C............................. A.10 S21-120-C0........................... A.10 S21-120-L.............................. A.10 S21-120-L0............................ A.10 S21-175-C............................. A.12 S21-175-C0........................... A.12 S21-175-L.............................. A.12 S21-175-L0............................ A.12 S24-120-L.............................. A.10 S24-120-L0............................ A.10 S24-120-Q............................. A.10 S24-120-Q0........................... A.10 S24-175-L.............................. A.12 S24-175-L0............................ A.12 S30-120-L.............................. A.10 S30-120-L0............................ A.10 S30-120-X............................. A.10 S30-120-X0........................... A.10 S31-175-L.............................. A.12 S31-175-L0............................ A.12 S32-175-L.............................. A.12 S32-175-L0............................ A.12 S36-175-L.............................. A.12 S36-175-L0............................ A.12 S40-175-L.............................. A.12 S40-175-L0............................ A.12 S40-175-X............................. A.12 S40-175-X0........................... A.12 S48-175-L.............................. A.12 S48-175-L0............................ A.12 S48-175-L8............................ A.12 SC8-50-S10-C........................ A.14 SC8-50-S10-C0...................... A.14 SC15-120-S25-L.................... A.14 SC15-120-S25-L0.................. A.14 SGPL12-7S-L............................F.2 SGPL12-8S-L............................F.2 SGPL12-10S-L..........................F.2 SGPL12-12S-L..........................F.2 SGPL14-8S-L............................F.2 SGPS12-8FT-L...........................F.2 SGPS12-8FT-L10.......................F.2 SGPS12-8FT-L20.......................F.2 SGPS12-8SRF-L........................F.2 SGPS12-8SRT-L........................F.2 SGPSL12-8SFT-Q......................F.2 SGPSS12-8SFF-Q......................F.2 SGPSS12-8SFT-Q......................F.2 SGPSSL12-8S-Q........................F.2 SGPSSS12-8S-Q........................F.2 SMP12A-3X............................ A.18 SMP12A-3X0.......................... A.18 SMP12A-C.............................. A.18 SMP12A-C0............................ A.18 SMP12A-M............................. A.18 SMP12A-M0........................... A.18 SMP16A-3X............................ A.18 SMP16A-3X0.......................... A.18 SMP16A-C.............................. A.18 SMP16A-C0............................ A.18 SMP16A-M............................. A.18 SMP16A-M0........................... A.18 SMP18A-3X............................ A.18 SMP18A-3X0.......................... A.18 SMP18A-C.............................. A.18 SMP18A-C0............................ A.18 SMP18A-M............................. A.18 SMP18A-M0........................... A.18 SR8-50-C............................... A.14 SR8-50-C0............................. A.14 SRB19BLY................................. J.8 SRBM19BLY.............................. J.8 SRBS19BL-XY........................... J.8 SS2S6-M0.............................. A.16 SSM2S6-3X............................ A.16 SSM2S6-3X0.......................... A.16 SSM2S6-C.............................. A.16 SSM2S6-C0............................ A.16 SSM2S6-M............................. A.16 SSM3S8-3X............................ A.16 SSM3S8-3X0.......................... A.16 SSM3S8-C.............................. A.16 SSM3S8-C0............................ A.16 SSM3S8-M............................. A.16 SSM3S8-M0........................... A.16 SSMLP-3X.............................. A.18 SSMLP-C................................ A.18 SSMLP-M............................... A.18 SSMTA-C................................ A.16 SSMTA-M............................... A.16 ST14-075-60BK.......................C.6 ST15-075-66GRYL...................C.6 ST17-075-66BR.......................C.6 ST17-075-66BU.......................C.6 ST17-075-66GR.......................C.6 ST17-075-66GY.......................C.6 ST17-075-66OR.......................C.6 ST17-075-66RD.......................C.6 ST17-075-66VI.........................C.6 ST17-075-66WH......................C.6 ST17-075-66YL........................C.6 ST35-075-66BR.......................C.5 ST35-075-66BU.......................C.5 ST35-075-66GR.......................C.5 ST35-075-66GY.......................C.5 ST35-075-66OR.......................C.5 ST35-075-66RD.......................C.5 ST35-075-66VI.........................C.5 ST35-075-66WH......................C.5 ST35-075-66YL........................C.5 ST43-075-66BK.......................C.5 ST88-075-66BK.......................C.4 ST88-100-108BK.....................C.4 ST88-150-66BK.......................C.4 ST88-200-66BK.......................C.4 T T70KW2IW.............................. J.11 T70KW4IW.............................. J.11 TTS-35R3-0...........................H.62 TTS-35RX0.............................H.62 W WB89D..................................... J.8 Call 866-405-6654 or visit www.panduit.com/stronghold M.7 Panduit is a global leader in cabling and communication products, delivering end-to-end solutions in support of demanding electrical and networking requirements. Panduit Catalogs Industrial Electrical Solutions ELCB31--SA-ENG • Bundle Cable Ties Cable Accessories Stainless Steel Cable Ties and Accessories • Route/Protect Wiring Duct Abrasion Protection Cable Management • Terminate Terminals Power Connectors Grounding Connectors • Identification and Safety Solutions Labeling Systems Labels Pre-Printed and Write-On Markers Permanent Identification Lockout/Tagout and Safety Solutions • Keystone Cabling Systems Network and Infrastructure Solutions NCCB93--SA-ENG • Copper Systems • Fiber Systems • Faceplates, Outlet Frames and Surface Mount Boxes • Keystone Cabling Systems • Zone Cabling • Cable Routing Systems • Surface Raceway M.8 • Cabinets, Racks and Cable Management Systems • Power Management • Grounding and Bonding • Identification Products • Cable Management Accessories Order number of pieces required, in multiples of Standard Package Quantity. Panduit Corporate World Headquarters Tinley Park, Illinois 60487 To learn more about Panduit’s full contractor offering visit www.panduit.com or contact Customer Service: 800-777-3300 © 2020 Panduit Corp. ALL RIGHTS RESERVED Printed in the U.S.A. Catalog Number ELCB32—SA-ENG Replaces CMCB02--SA-ENG 8/2020
S14-120-L0 价格&库存

很抱歉,暂时无法提供与“S14-120-L0”相匹配的价格&库存,您可以联系我们找货

免费人工找货
S14-120-L0
  •  国内价格 香港价格
  • 50+1.7171350+0.22261

库存:0