PED302S~ED306S
SUPERFAST RECOVERY RECTIFIERS
200~600 V
Voltage
3A
Current
Features
Plastic package has Underwriters Laboratories
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound
Superfast recovery times-epitaxial construction.
Low forward voltage, high current capability.
Exceeds environmental standards of MIL-S-19500/228.
Hermetically sealed.
Low leakage.
High surge capability.
Lead free in compliance with EU RoHS 2011/65/EU directive.
Green molding compound as per IEC61249 Std..(Halogen Free)
Mechanical Data
Case: TO-252 Molded plastic
Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
Polarity: As marking
Approx. Weight: 0.0104 ounces, 0.297 grams
Marking: Part number
o
Maximum Ratings (TA=25 C unless otherwise noted)
PARAMETER
SYMBOL
ED302S
ED303S
ED304S
ED306S
UNIT
Maximum repetitive peak reverse voltage
VRRM
200
300
400
600
V
Maximum rms voltage
VRMS
140
210
280
420
V
VR
200
300
400
600
V
Maximum dc blocking voltage
Maximum average forward rectified current
Peak forward surge current : 8.3ms single half sinewave superimposed on rated load
Maximum forward voltage at 3A
Maximum dc reverse current
at rated dc blocking voltage
IF(AV)
3
A
IFSM
75
A
VF
o
TJ=25 C
o
0.95
1.25
1.7
V
1
A
IR
TJ=125 C
300
Maximum reverse recovery time
TRR
35
nS
Typical junction capacitance
CJ
45
pF
RJA
25
TJ,TSTG
-55 to +150
Typical thermal resistance
Operating junction and storage temperature range
November 25,2014-REV.03
o
C/W
o
C
Page 1
PED302S~ED306S
INSTNTANEOUS FORWARD CURRENT
AMPERES
AVERAGE FORWARD CURRENT,
AMPERES
RATING AND CHARACTERISTIC CURVES
10.0
8.0
6.0
4.0
2.0
0
0
50
150
100
O
CASE TEMPERATURE, C
40
10
200V
300-400V
600V
1
O
T J =25 C
Pulse Width=200us
.1
.6
.8
1.0
1.2
1.4
1.6
1.8
2.0
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
Fig.2-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTIC
Fig.1-FORWARD CURRENT DERATING CURVE
PEAK FORWARD SURGE CURRENT,
AMPERES
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
1000
O
TJ= 125 C
100
O
TJ= 75 C
10
1.0
0.1
O
TJ= 25 C
20
40
60
80
100
85
8.3ms Single Half Since-Wave
JEDEC Method
75
65
55
45
35
25
15
5
1
2
5
10
20
50
100
120
NO. OF CYCLES AT 60Hz
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
Fig.3-TYPICAL REVERSE CHARACTERISTICS
Fig.4-MAXIMUM NON-REPETITIVE SURGE CURRENT
18
16
O
Tj= 25 C
f= 1 .0MHz
Vsig = 50mVp -p
CAPACITANCE, pF
14
12
10
8.0
6.0
4.0
2.0
0
0.1
1
10
100
REVERSE VOLTAGE, VOLTS
Fig.5-TYPICAL JUNCTION CAPACITANCE
November 25,2014-REV.03
Page 2
PED302S~ED306S
MOUNTING PAD LAYOUT
ORDER INFORMATION
˙Packing information
T/R – 3K per 13" plastic Reel
November 25,2014-REV.03
Page 3
PED302S~ED306S
Part No_packing code_Version
ED302S_L2_00001
ED302S_S2_00001
For example :
RB500V-40_R2_00001
˙Serial number
˙
˙Version code means HF
Part No.
˙Packing size code means 13"
˙Packing type means T/R
Packing Code XX
Version Code XXXXX
Packing type
1st
Code
Packing size code
2nd
Code
HF or
RoHS
1st Code
2nd~5th Code
Tape and Ammunition
Box (T/B)
A
N/A
0
HF
0
serial number
Tape and Reel (T/R)
R
7"
1
RoHS
1
serial number
Bulk Packing (B/P)
B
13"
2
Tube Packing (T/P)
T
26mm
X
Tape and Reel (Right Oriented)
(TRR)
S
52mm
Y
Tape and Reel (Left Oriented)
(TRL)
L
PANASERT T/B
CATHODE UP (PBCU)
U
FORMING
F
PANASERT T/B
CATHODE DOWN (PBCD)
D
November 25,2014-REV.03
Page 4
PED302S~ED306S
Disclaimer
● Reproducing and modifying information of the document is prohibited without permission from Panjit
International Inc..
● Panjit International Inc. reserves the rights to make changes of the content herein the document
anytime without notification. Please refer to our website for the latest document.
● Panjit International Inc. disclaims any and all liability arising out of the application or use of any
product including damages incidentally and consequentially occurred.
● Panjit International Inc. does not assume any and all implied warranties, including warranties of
fitness for particular purpose, non-infringement and merchantability.
● Applications shown on the herein document are examples of standard use and operation. Customers
are responsible in comprehending the suitable use in particular applications. Panjit International Inc.
makes no representation or warranty that such applications will be suitable for the specified use
without further testing or modification.
● The products shown herein are not designed and authorized for equipments requiring high level of
reliability or relating to human life and for any applications concerning life-saving or life-sustaining,
such as medical instruments, transportation equipment, aerospace machinery et cetera. Customers
using or selling these products for use in such applications do so at their own risk and agree to fully
indemnify Panjit International Inc. for any damages resulting from such improper use or sale.
● Since Panjit uses lot number as the tracking base, please provide the lot number for tracking when
complaining.
November 25,2014-REV.03
Page 5
很抱歉,暂时无法提供与“ED306S_S2_00001”相匹配的价格&库存,您可以联系我们找货
免费人工找货