ER2A~ER2J
SURFACE MOUNT RECTIFIER
VOLTAGE
50 to 600 Volt
CURRENT
2 Ampere
FEATURES
• For surface mounted applications in order to optimize board space
• High temperature metallurgically bonded-no compression
contacts as found in other diode-constructed rectifiers
• Glass passivated junction
• Easy pick and place
• Plastic package has Underwriters Laboratory Flammability
Classification 94V-O
• Lead free in compliance with EU RoHS 2.0
• Green molding compound as per IEC 61249 standard
MECHANICAL DATA
• Case: JEDEC DO-214AA molded plastic
• Terminals: Solder plated, solderable per MIL-STD-750, Method 2026
• Polarity: Color band denotes cathode end
• Standard packaging: 16mm tape (EIA-481)
• Weight: 0.0032 ounces, 0.092 grams
1
2
Cathode
Anode
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
PARAMETER
SYMBOL
ER2A
ER2B
ER2C
ER2D
ER2E
ER2G
ER2J
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
150
200
300
400
600
V
Maximum RMS Voltage
VRMS
35
70
105
140
210
280
420
V
Maximum DC Blocking Voltage
VDC
50
100
150
200
300
400
600
V
Maximum Average Forward Current
TL=110OC
IF(AV)
2
A
Peak Forward Surge Current : 8.3ms single half sine-wave
superimposed on rated load
IFSM
50
A
Maximum Forward Voltage at 2A
VF
0.95
1.25
1.7
V
IR
1
150
μA
Maximum Reverse Recovery Time (Note 1)
trr
35
ns
Typical Junction Capacitance (Note 2)
CJ
25
pF
Typical Thermal Resistance (Note 3)
RθJL
20
O
Typical Thermal Resistance (Note 3)
RθJC
15
O
TJ,TSTG
-55 to +150
Maximum DC Reverse Current at Rated DC
Blocking Voltage
Operating Junction and Storage Temperature Range
TJ=25OC
TJ=100OC
C/W
C/W
C
O
NOTES:1. Reverse Recovery Test Conditions: I F=0.5A, I R=-1A, I rr=-0.25A
2. Measured at 1 MHz and applied Vr = 4 volts.
3. Mounted on a FR4 PCB, single-sided copper, with 100cm 2 copper pad area.
May 7,2018REV.10
PAGE . 1
ER2A~ER2J
RATING AND CHARACTERISTIC CURVES
70
60
2.4
2 .0
CAPACITANCE, pF
AVERAGE FORWARD RECIFIED
CURRENT AMPERES
2.8
1.6
1 .2
.8
SINGLE PHASE, HALF-WAVE, 60Hz RESISTIVE
OR INDUCTIVE LOAD P.C.B MOUNTED
ON 0.3 x 0.3" (8.0 x 8.0 mm)COPPER PAD AREAS
.4
20
40
60
80
40
30
20
O
TJ = 25 C
f = 1.0MHZ
Vsig = 50mVp-p
10
0
0
50
100
120
140
160
180
0
0.1
LEAD TEMPERATURE, OC
1
10
100
1000
REVERSE VOLTAGE, VOLTS
FIG.2 TYPICAL JUNCTION CAPACITANCE
FIG.1 MAXIMUM AVERAGE FORWARD CURRENT RATING
100
INSTANTANEOUS FORWARD CURRENT AMPERES
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
1000
O
TJ= 125 C
100
O
TJ= 75 C
10
1.0
0.1
O
TJ= 25 C
20
40
60
80
100
10
50-200V
300-400V
1.0
600V
0.1
O
T J = 25 C
120
.01
0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
INSTANTANEOUS FORWARD VOLTAGE VOLTS
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 TYPICAL FORWARD CHARACTERISTICS
FORWARD SURGE CURRENT, AMPERES
(HALF-SING WAVE)
60
50
40
30
20
10
8.3ms SINGLE HALF SINE-WAVE
JEDC METHOD
0
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPEITIVE SURGE CURRENT
May 7,2018REV.10
PAGE . 2
ER2A~ER2J
MOUNTING PAD LAYOUT
ORDER INFORMATION
• Packing information
T/R - 3K per 13" plastic Reel
T/R - 0.8K per 7" plastic Reel
May 7,2018REV.10
PAGE . 3
ER2A~ER2J
Part No_packing code_Version
ER2A_R1_00001
ER2A_R2_00001
For example :
RB500V-40_R2_00001
Serial number
Version code means HF
Packing size code means 13"
Part No.
Packing type means T/R
Packing Code XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
May 7,2018REV.10
Version Code XXXXX
1st Code
Packing size code
A
N/A
0
HF
0
serial number
R
7"
1
RoHS
1
serial number
B
13"
2
T
26mm
X
S
52mm
Y
L
F
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
2nd Code HF or RoHS 1st Code 2nd~5th Code
U
D
PAGE . 4
ER2A~ER2J
Disclaimer
• Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
• Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
• Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
• Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
• Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
Panjit International Inc. makes no representation or warranty that such applications will be
suitable for the specified use without further testing or modification.
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
• Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
May 7,2018REV.10
PAGE . 5
很抱歉,暂时无法提供与“ER2J”相匹配的价格&库存,您可以联系我们找货
免费人工找货