ER300~ER308
GLASS PASSIVATED SUPERFAST RECOVERY RECTIFIERS
VOLTAGE
50 to 800 Volt
3 Ampere
CURRENT
FEATURES
0.052(1.3)
0.048(1.2)
1.0(25.4)MIN.
• Superfast recovery times-epitaxial construction.
• Low forward voltage, high current capability.
• Hermetically sealed.
• Low leakage.
0.375(9.5)
0.285(7.2)
• High surge capability.
• Plastic package has Underwriters Laboratories
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound.
• Lead free in compliance with EU RoHS 2.0
1.0(25.4)MIN.
0.210(5.3)
0.188(4.8)
MECHANICAL DATA
• Case: Molded plastic, DO-201AD
• Terminals: Axial leads, solderable to MIL-STD-750,Method 2026
• Polarity: Color band denotes cathode end
• Weight: 0.04 ounce, 1.122 gram
1
2
Cathode
Anode
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
Resistive or inductive load, 60Hz.
PARAM ETE R
SY M BO L ER300 ER3 01 ER301 A ER302
ER303 ER304 ER306 ER306A ER308 UNI TS
M aximum Recur r ent P eak R eve r se Volt age
V RRM
50
1 00
15 0
200
300
400
60 0
7 00
80 0
V
M aximum R M S Volt age
V RM S
35
70
10 5
140
210
280
42 0
49 0
5 60
V
M aximum DC B loc king Volt age
V DC
50
1 00
15 0
200
300
400
60 0
7 00
80 0
V
M aximum A ve r age F o r w ar d Cur r ent 0. 375" ( 9. 5mm)
lead l eng t h at T A = 55 O C
I F(AV)
3
A
Peak F or w a r d S ur ge C ur r ent : 8. 3ms s ingle half s ine w ave s uper imposed on r at ed load
I FSM
125
A
M aximum F or w ar d Volt age at 3A D C
VF
1. 2 5
1. 7
2
2. 5
V
IR
1
300
μA
M aximum Rever s e R e cove r y Time ( Not e 1)
t rr
35
ns
Ty pic al J unc t ion Capac it anc e ( Not e 2)
CJ
35
pF
R θJ A
20
T J , T STG
- 5 5 t o + 150
M aximum DC Rever s e C ur r ent at Rat ed D C
Block ing Volt age
Ty pic al J unc t ion Resi s t anc e ( Not e 3)
O pe r at ing and S t or age Temper at ur e Range
T J = 25 O C
T J = 125 O C
0. 95
O
C/
W
O
C
NOTES:1. Reverse Recovery Test Conditions: I F=0.5A, I R=-1A, I rr=-0.25A
2. Measured at 1 MHz and applied reverse voltage of 4 VDC
3. Thermal resistance from junction to ambient and from junction to lead length 0.375"(9.5mm) P.C.B. mounted
April 18,2018-REV.06
PAGE . 1
ER300~ER308
April 18,2018-REV.06
PAGE . 2
ER300~ER308
Part No_packing code_Version
ER300_AY_00001
ER300_AY_10001
ER300_B0_00001
ER300_B0_10001
ER300_R2_00001
ER300_R2_10001
For example :
RB500V-40_R2_00001
Serial number
Part No.
Version code means HF
Packing size code means 13"
Packing type means T/R
Packing Code XX
Packing type
Tape and Ammunition Box
(T/B)
Tape and Reel
(T/R)
Bulk Packing
(B/P)
Tube Packing
(T/P)
Tape and Reel (Right Oriented)
(TRR)
Tape and Reel (Left Oriented)
(TRL)
FORMING
April 18,2018-REV.06
Version Code XXXXX
1st Code
Packing size code
A
N/A
0
HF
0
serial number
R
7"
1
RoHS
1
serial number
B
13"
2
T
26mm
X
S
52mm
Y
L
F
PANASERT T/B CATHODE UP
(PBCU)
PANASERT T/B CATHODE DOWN
(PBCD)
2nd Code HF or RoHS 1st Code 2nd~5th Code
U
D
PAGE . 3
ER300~ER308
Disclaimer
• Reproducing and modifying information of the document is prohibited without permission
from Panjit International Inc..
• Panjit International Inc. reserves the rights to make changes of the content herein the
document anytime without notification. Please refer to our website for the latest
document.
• Panjit International Inc. disclaims any and all liability arising out of the application or use of
any product including damages incidentally and consequentially occurred.
• Panjit International Inc. does not assume any and all implied warranties, including warranties
of fitness for particular purpose, non-infringement and merchantability.
• Applications shown on the herein document are examples of standard use and operation.
Customers are responsible in comprehending the suitable use in particular applications.
Panjit International Inc. makes no representation or warranty that such applications will be
suitable for the specified use without further testing or modification.
•
The products shown herein are not designed and authorized for equipments requiring high
level of reliability or relating to human life and for any applications concerning life-saving
or life-sustaining, such as medical instruments, transportation equipment, aerospace
machinery et cetera. Customers using or selling these products for use in such applications
do so at their own risk and agree to fully indemnify Panjit International Inc. for any damages
resulting from such improper use or sale.
• Since Panjit uses lot number as the tracking base, please provide the lot number for tracking
when complaining.
April 18,2018-REV.06
PAGE . 4
很抱歉,暂时无法提供与“ER306A_R2_00001”相匹配的价格&库存,您可以联系我们找货
免费人工找货