AC Power Line Choke
ELECTRONICS INC.
EPZ3060LP-XXX
• Used as AC Power Line Filters in CTV, VTR, Audios, PC’s, Facsimilies and Power Supply Applications • Applicable Frequency : 0.1 MHz to 10 MHz • Low Profile In Vertical Core Layout • UL940-V Recognized Materials • UL1446 Insulating System • 2-Section Bobbin
Electrical Parameters @ 25° C
Part Number Inductance (mH Min.) [Pins 1-2, 4-3] Current Rating (A rms Max.) 1000
Impedance Characteristics
1.5 EPZ3060LP-152 2.0 1.8 EPZ3060LP-182 1.7 2.2 EPZ3060LP-222 1.5 3.0 EPZ3060LP-302 1.3 3.5 EPZ3060LP-352 1.2 5.5 EPZ3060LP-552 1.0 7.4 EPZ3060LP-742 0.8 10 EPZ3060LP-103 0.7 12 EPZ3060LP-123 0.6 20 EPZ3060LP-203 0.5 30 EPZ3060LP-303 0.4 43 EPZ3060LP-433 0.3 • Isolation : 2000 Vrms • Temperature Rise : 60°C Max. •
100 Impedance (KΩ )
10
1
0.1
Circuit Sample
.01 MHz 30 mH 20 mH 10 mH
0.1 1 MHz MHz Frequency (Hz) 8 mH 5 mH 2 mH 1 mH
10 MHz
AC Line
Schematic Package
.709 Max. (18.00)
Marking : PCA EPZ3060LP-XXX D.C.
1 1:1 4
2 3
.630 Max. (16.00)
Pin 1 I.D. .138 ± .039 (3.50 ± 1.00)
.689 Max. (17.50)
Recommended PWB Piercing Plan .047 Ø ± .004 (1.20 Ø ± .100) 1 2 .512 ± .002 (13.00 ± .050) 4 3 .394 ± .002 (10.00 ± .050)
.512 ± .020 (13.00 ± .500) 4 1 .035 Ø Max. (.900 Ø)
.394 ± .020 (10.00 ± .500)
3
2
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25 PCA ELECTRONICS, INC. 16799 SCHOENBORN ST. NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSZ3060LP-XXX Rev. 11/18/02
TEL: (818) 892-0761 FAX: (818) 894-5791 http://www.pca.com