DATASHEET
Lighting
Imaging
Telecom
Machine Vision Illumination Systems
MVS-4100, 4200 Machine Vision Strobe
Description
The PerkinElmer Optoelectronics MVS 4100 and MVS 4200 are costeffective strobes for a wide variety of industrial inspection applications. The linear xenon flashlamp, mounted in a reflector for maximum intensity, provides 6 microsecond pulses at flash rates up to 100 Hz. The energy-perflash remains constant at 180 mJ; no range-switching is needed. These 20 Watt strobes are housed in a convection-cooled, rugged enclosure. Threaded hoses at the bottom of the enclosure allow the unit to be hard mounted. The MVS 4100 has an optically isolated trigger input and requires an external +5V TTL pulse to flash. The MVS 4200 has an internal oscillator and can be run in either external or internal trigger mode. The MVS 4200 is ideal as a stand-alone unit for “stroboscopic” applications.
Features
• Low cost • Compact/light weight • Universal AC input (90–230 VAC, 560/60 Hz) • Long life xenon flashlamp • Flash rates to 100 Hz • Pulse duration 6 µsec • Internal/external trigger • Convection cooled
. www.perkinelmer.com/opto
MVS-4100, 4200
Optical Specifications
300 to 1100+ nm Spectral bandwidth (1) Up to 100 Hz (6,000 fpm) Flash rate >108 flashes Flashlamp life (3) Flash duration (2) 6 microseconds Flash to flash variation < 5% Illumination Characteristics
Distance 6 inches 1 foot 2 feet 3 feet
Note 1: Note 2: Note 3: Note 4: Note 5: Note 6:
Area Illuminated 6 in. x 8 in. 12 in. x 16 in. 20 in. x 23 in. 36 in. x 48 in.
Photometric 19 lux-sec 5.7 lux-sec 1.5 lux-sec 0.6 lux-sec
Radiometric 15 x 10-6 J/cm2 4.5 x 10-6 J/cm2 1.2 x 10-6 J/cm2 0.5 x 10-6 J/cm2
Spectral bandwidth may be extended into the ultraviolet with other flashlamp envelope and enclosure window materials. Contact factory for IR or UV filters. Measured at 1/3 peak value. Prior to light output decreasing to 50% of the initial value. Area where energy is not less than 50% of maximum. Lux-sec = Lumen-sec/m2. Delay between flash command and light output is 8 µsec typical.
Electrical Specifications
Input voltage Input current Flashlamp voltage Discharge capacitor Discharge energy Discharge power Tirgger input: (1) Trigger Pulse duration Internal oscillator 90 - 230 ±10% VAC, 50/60 Hz 2.0 amps maximum 600 volts 1.0 microfarad ± 10% 0.18 Joules (± 10%) 20 watts maximum +5 volt pulse into opto-isolator with 150 ohm nominal series resistor 10 to 100 microseconds 10 - 100 Hz (10 turn potentiometer) (MVS-4200 only)
Physical Specifications
TRIGGER
INTERNAL FLASH RATE
4.88 (124.0)
AC INPUT ON-OFF SWITCH
EXT
INT INT
8.25 (209.6)
9 PIN CONNECTOR
POWER EXTERNAL TRIGGER
2.51 1.50 (63.8) (38.1)
50-60HZ 100-240VAC 2A MAX
REAR VIEW 0.50 (12.7)
6.75 (171.5) 0.56 (14.2)
1.88 (47.6)
1/4-20 X .27(6.9) DEEP MOUNTING HOLES 3 PLACES
2.43 (61.7) 0.56 (14.2)
For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto. All values are nominal; specifications subject to change without notice.
USA: PerkinElmer Optoelectronics 35 Congress Street Salem, MA 01970 Toll Free: (800) 950-3441 (USA) Phone: (978) 745-3200 Fax: (978) 745-0894
© 2001 PerkinElmer inc. All rights reserved.
Europe: PerkinElmer Optoelectronics
Wenzel-Jaksch-Str. 31, D-65199 Weisbaden, Germany Phone: +49 (0) 611-492-437 Fax: +49 (0)611-492-159
Asia: PerkinElmer Optoelectronics 47 Ayer Rajah Crescent #06-12 Singapore 139947 Phone: +65 775 2022 Fax: +65 775 1008
.
0601