1020304

1020304

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    通信模块 DIN 轨道 19.2 ~ 30VDC

  • 数据手册
  • 价格&库存
1020304 数据手册
AXC F IL ADAPT PLCnext Technology, Inline adapter terminal (INTERBUS master), right-alignable Data sheet 108629_en_00 1 © PHOENIX CONTACT 2018-10-05 Description The Inline adapter terminal (INTERBUS master) is designed to be aligned to the right of an AXC F ... PLCnext controller. The Inline adapter terminal can be used to set up a PLCnext Inline station and integrate INTERBUS devices. Features – – – Automatic detection of the transmission speed in INTERBUS (500 kbps or 2 Mbps) Up to 63 INTERBUS devices can be connected Diagnostic and status indicators NOTE: Device defect due to impermissible firmware version The Inline adapter terminal is designed to be aligned to the right of PLCnext controllers with specific firmware versions. If you align the Inline adapter terminal next to a PLCnext controller with a firmware version that is not permitted, this can cause a device defect to the PLCnext controller. Make sure that the Inline adapter terminal is only aligned next to a PLCnext controller with a firmware version that is permitted. AXC F ... PLCnext controllers with the following firmware versions are permitted: – AXC F 2152 with firmware Version  1.2 Please note: Align the Inline adapter terminal directly on the controller. Axioline F modules may not be aligned on the controller. This data sheet is only valid in association with the Axioline F system manual and the user manual for the Axioline F controller being used. Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.net/product/1020304 AXC F IL ADAPT 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 4 5 Module components ................................................................................................................ 7 6 Internal circuit diagram ............................................................................................................ 8 7 Design of a PLCnext Inline station ........................................................................................... 9 8 Mounting................................................................................................................................ 10 8.1 Removing the controller ...................................................................................................... 10 8.2 Mount bus base module ...................................................................................................... 10 8.3 Snapping on the controller ................................................................................................... 11 8.4 Snapping on electronics modules .......................................................................................... 11 8.5 Mount Inline connector ........................................................................................................ 11 9 Connecting the supply voltage............................................................................................... 12 10 Connection example.............................................................................................................. 13 11 Diagnostics and status indicators .......................................................................................... 14 12 Supported INTERBUS master services ................................................................................. 15 13 PCP communication .............................................................................................................. 18 108629_en_00 PHOENIX CONTACT 2 / 18 AXC F IL ADAPT 3 Ordering data Description Order No. Pcs./Pkt. Right-alignable Inline adapter terminal (INTERBUS AXC F IL ADAPT master) for a PLCnext controller for setting up a PLCnext Inline station 1020304 1 Documentation Order No. Pcs./Pkt. User manual, English, Axioline F: System and installation UM EN AXL F SYS INST - - User manual, English, Axioline F: Diagnostic registers, and error messages UM EN AXL F SYS DIAG - - User Manual, English, for diagnosis in Generation 4 controller boards IBS SYS DIAG DSC UM E 2747293 1 User manual, English, for the Peripherals Communication IBS PCP UM E Protocol (PCP), only available as a download. 2753931 1 User manual, English, for the Peripherals Communication IBS SYS PCP G4 UM E Protocol (PCP), only available as a download. 2745169 1 108629_en_00 Type Type PHOENIX CONTACT 3 / 18 AXC F IL ADAPT 4 Technical data Dimensions (nominal sizes in mm) 71,5 119,8 Width 12.2 mm Height 119.8 mm Depth 71.5 mm General data Weight 66 g Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 10 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Mounting type DIN rail mounting Connection data: Inline connector Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm² ... 1.5 mm² / 0.08 mm² ... 1.5 mm² Conductor cross section [AWG] 28 ... 16 Stripping length 8 mm System limits Amount of process data max. 4096 Bit (INTERBUS) Number of local bus devices that can be connected max. 63 (observe current consumption) Number of devices with parameter channel max. 62 24 V supply UILC Supply voltage 24 V DC -15 % / +20 % (acc. to EN 61131-2) Current draw 20 mA 108629_en_00 PHOENIX CONTACT 4 / 18 AXC F IL ADAPT 7.5 V communications power UL (potential jumper) Supply voltage 7.5 V DC ±5 % Power supply unit max. 0.8 A DC (observe derating) 24 V analog supply UANA (potential jumper) Supply voltage 24 V DC -15 % / +20 % Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply unit 0.5 A DC (observe derating) 24 V main supply UM Supply voltage 24 V DC -15 % / +20 % (acc. to EN 61131-2) Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply unit max. 8 A DC (sum of UM + US) 24 V segment supply US Supply voltage 24 V DC -15 % / +20 % (in accordance with EN 61131) Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Power supply unit max. 8 A (sum of UM + US) Protective circuit Polarity reversal protection of the supply voltage Polarity protection diode Transient protection Suppressor diode Protection NOTE: Damage to the electronics Provide external protection for the module to protect it against polarity reversal. The power supply unit and the external fuse must be coordinated so that safe tripping is ensured in the event of an error. Error messages to the higher level control or computer system Bus error in INTERBUS Yes Peripheral fault in INTERBUS Yes Mechanical tests Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse Continuous shock according to EN 60068-2-27/ IEC 60068-2-27 10g Vibration resistance in acc. with EN 60068-2-6/ IEC 60068-2-6 2g Conformance with EMC Directive 2014/30/EU Noise immunity test in accordance with EN 61000-6-2 EN 61000-4-2 (ESD) Electrostatic discharge (ESD) EN 61000-4-2/ IEC 61000-4-2 Criterion B, 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 (electromagnetic fields) Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m EN 61000-4-4 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV 108629_en_00 PHOENIX CONTACT 5 / 18 AXC F IL ADAPT Conformance with EMC Directive 2014/30/EU EN 61000-4-5 (surge) Transient overvoltage (surge) EN 61000-4-5/ IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/ asymmetrical) EN 61000-4-6 (line noise immunity) Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test as per EN 61000-6-4 Class A Approvals For the latest approvals, please visit phoenixcontact.net/products. 108629_en_00 PHOENIX CONTACT 6 / 18 AXC F IL ADAPT 5 Module components U IL FA PF B S A R D Y 5 4 3 2 1 Figure 1 1 2 3 4 5 Module components Bus base module Electronics module Inline connector Terminal points Diagnostic and status indicators 108629_en_00 PHOENIX CONTACT 7 / 18 AXC F IL ADAPT 6 Internal circuit diagram 3,3V 5V IB RDY UL+ UANA FAIL ULBSA & PF 7,5V 24V 24V P Local bus U 24V US UM S UL US UM PWR Figure 2 Basic circuit diagram Key: Power supply unit Protocol chip IB LED AND gates & P Parallel-to-serial converters S 108629_en_00 PHOENIX CONTACT 8 / 18 AXC F IL ADAPT 7 Design of a PLCnext Inline station 3 4 5 SD-CARD MAC Addr.: XX.XX.XX.XX.XX.XX 1 Ord. No. 2404267 AXC F 2152 2 R X4 1 RDY FAIL BSA PF U X2 X1 Figure 3 1 2 3 4 5 Design of a PLCnext Inline station End clamp (e.g., CLIPFIX 35-5, Order No. 3022276) PLCnext controller for Axioline F (in the example: AXC F 2152) Inline adapter terminal Inline terminals corresponding to the application End plate (snap onto the DIN rail as station end) 108629_en_00 PHOENIX CONTACT 9 / 18 AXC F IL ADAPT 8 Mounting Please note: 8.1 Removing the controller The controller must be removed in order to mount the bus base module of the Inline adapter terminal. On a controller for Axioline F, only one Inline adapter terminal may be aligned to the right. 52 21 F X X C .X A X .X X .X X .X X r.: X X D .X R X R A -C O rd .N o. 24 04 26 7 D M A C A dd 4 • 8.2 1 The Inline adapter terminal is designed to be aligned to the right of PLCnext controllers with specific firmware versions. If you align the Inline adapter terminal next to a PLCnext controller with a firmware version that is not permitted, this can cause a device defect to the PLCnext controller. X NOTE: Device defect due to impermissible firmware version 2 • X Figure 4 2 X A 1 X Mount all the necessary modules before supplying power to the PLCnext Inline station. Modules to which power is only supplied following the controller boot process are not detected or may result in a malfunction. To ensure that the Inline adapter terminal is detected correctly, proceed as follows: - Switch on the power to the Inline adapter terminal before switching on the power to the controller or - Switch on the power to the Inline adapter terminal and the controller simultaneously. A S B Please note: Removing the controller Insert a suitable tool (e.g., bladed screwdriver) into the upper and lower snap-on mechanisms (base latches) of the controller one after the other and release it (A). The base latches are latched in place in the open position. Remove the controller perpendicular to the DIN rail (B). Mount bus base module A Make sure that the Inline adapter terminal is only aligned next to a PLCnext controller with a firmware version that is permitted. B AXC F ... PLCnext controllers with the following firmware versions are permitted: – AXC F 2152 with firmware Version  1.2 Figure 5 • • Mounting the bus base module Place the bus base module of the Inline adapter terminal on the DIN rail (A). Push the bus base module of the Inline adapter terminal into the connection of the bus base module on the controller (B). Please note: Align the Inline adapter terminal directly on the controller. Axioline F modules may not be aligned on the controller. 108629_en_00 PHOENIX CONTACT 10 / 18 AXC F IL ADAPT Snapping on the controller 8.5 Mount Inline connector X .X .X X .X X .X X D D X M A C 4 r.: X X R .X X R A -C A dd S O rd .N o. 24 04 26 7 A X C F 21 52 8.3 B 1 X 2 X X 2 X 1 A Figure 8 • Figure 6 • • 8.4 • • Insert the Inline connectors in the specified order (A, B). Snapping on the controller Place the controller vertically on the first bus base module and the DIN rail until it snaps into place with a click. Make sure that the device connector for the bus base connection is situated above the corresponding socket on the bus base module. Snapping on electronics modules Figure 7 • Insert Inline connector Snapping on the electronics module of the Inline adapter terminal Place the electronics module of the Inline adapter terminal vertically on the corresponding bus base module and on the DIN rail until it snaps into place with a click. Make sure that the device connector for the bus base connection is situated above the corresponding socket on the bus base module. Mount the electronics modules of all necessary Inline terminals. Note the assembly instructions in the devicespecific packing slip. 108629_en_00 PHOENIX CONTACT 11 / 18 AXC F IL ADAPT 9 Connecting the supply voltage Terminal point assignment NOTE: Device defect due to impermissible firmware version The Inline adapter terminal is designed to be aligned to the right of PLCnext controllers with specific firmware versions. If you align the Inline adapter terminal next to a PLCnext controller with a firmware version that is not permitted, this can cause a device defect to the PLCnext controller. Make sure that the Inline adapter terminal is only aligned next to a PLCnext controller with a firmware version that is permitted. AXC F ... PLCnext controllers with the following firmware versions are permitted: – AXC F 2152 with firmware Version  1.2 A 8 B C Figure 9 • • • • Connecting cables Strip 8 mm off the cables. Release the spring by pressing with the screwdriver. Insert the cable into the terminal point. Secure the cable by removing the screwdriver. Figure 10 1.1 1.1 2.1 2.1 1.2 1.2 2.2 2.2 1.3 1.3 2.3 2.3 1.4 1.4 2.4 2.4 Terminal point assignment Terminal point 1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4 Assignment US (24 V DC) UILC (24 V DC) GND UILC FE UM (24 V DC) UM (24 V DC) GND UM/US FE Key: US (24 V DC) UM (24 V DC) UILC (24 V DC) GND FE 24 V supply for segment circuit 24 V supply for main circuit 24 V main voltage / 7.5 V logic supply / 24 V analog supply Ground Functional earth ground Recommended: flat-bladed screwdriver with blade dimensions of 0.6 mm x 3.5 mm x 100 mm (e. g., SZF 1-0,6X3,5, Order No. 1204517) 108629_en_00 PHOENIX CONTACT 12 / 18 AXC F IL ADAPT Figure 11 I/O I/O I/O AXC F IL ADAPT Connection example AXC F... 10 Connection example Key: AXC F ... AXC F IL ADAPT I/O INTERBUS 108629_en_00 AXC F ... PLCnext controller Inline adapter terminal Inline terminals corresponding to your application INTERBUS devices according to your application PHOENIX CONTACT 13 / 18 AXC F IL ADAPT 11 Diagnostics and status indicators RDY FAIL BSA PF U Figure 12 Diagnostic and status indicators Designation RDY Color Meaning State Description Green INTERBUS master FAIL Red Error BSA Yellow Bus segment PF Yellow Peripheral fault U Green Supply voltages US, UM, UL On Flashing OFF On OFF On OFF On OFF On INTERBUS master in the RUN state INTERBUS master in the READY or ACTIVE state INTERBUS master is not ready to operate Bus, controller or user error No error At least one bus segment aborted No bus segment aborted Peripheral fault on at least one device in INTERBUS No peripheral fault Supply voltages US, UM, UL present OFF At least one of the supply voltages US, UM or UL is not present 108629_en_00 PHOENIX CONTACT 14 / 18 AXC F IL ADAPT 12 Supported INTERBUS master services For more detailed information on the INTERBUS G4 services, please refer to the IBS SYS FW G4 UM E user manual. The user manual can be downloaded at phoenixcontact.net/products. The following restrictions apply for the INTERBUS master: - Support for INTERBUS devices with slave protocol chip SUPI3 or higher - No FO diagnostics - No single-channel diagnostics - No support for LPC1 or LPC2 - No isolated disconnection possible Firmware services are used to carry out the configuration, parameterization, and diagnostics of INTERBUS. The Inline adapter terminal (INTERBUS master) supports the following INTERBUS G4 services (some of which have a limited scope of functions): Code (hex) 0306 Service Initiate_Load_Configuration 0307 Load_Configuration 0308 Terminate_Load_Configuration 0309 Read_Configuration 108629_en_00 Description Create configuration frame for data transmission - Max. 127 characters - Can only be set when New_Config = 1 Transmit the device data for a configuration Used_Attributes: Bit 0: device number Bit 1: device code Bit 2: reserved Bit 3: device level Bit 4: logical group number (always FFFFhex) Bits 5 ... 13: reserved Bit 14: extended device information Bit 15: reserved Terminate the transmission of configuration data (only for automatic parameterization) Default_Parameter: The PCP channel is always parameterized automatically. The process data channel is only parameterized automatically if bit 0 is set. Read various entries of the configuration directory Used_Attributes: Bit 0: device number Bit 1: device code Bit 2: reserved Bit 3: device level Bit 4: logical group number Bits 5 ... 7: reserved Bit 8: global_bus_error Bit 9: separate_bus_error (Reconf and Watchdog not supported) Bit 10: device status Bits 11 ... 13: reserved Bit 14: extended device information Bit 15: reserved PHOENIX CONTACT 15 / 18 AXC F IL ADAPT Code (hex) 030A Service Complete_Load_Configuration 030B Complete_Read_Configuration 030C Delete_Configuration 030E 030F 0314 Control_Parameterization Control_Statistics Control_Device_Function_Not_Exclusive 0315 Read_Device_State 0316 0328 Get_Error_Info Compact_Load_Process_Data_Reference_List 0329 Compact_Read_Process_Data_Reference_List 032A 032B 0351 Get_Version_Info Get_Diag_Info Read_Value 0701 0702 Start_Data_Transfer Stop_Data_Transfer 108629_en_00 Description Transmit all the device data for a configuration Used_Attributes: Bit 0: device number Bit 1: device code Bit 2: reserved Bit 3: device level Bit 4: logical group number (always FFFFhex) Bits 5 ... 13: reserved Bit 14: extended device information Bit 15: reserved Read all the device data for a configuration Used_Attributes: Bit 0: device number Bit 1: device code Bit 2: reserved Bit 3: device level Bit 4: logical group number (always FFFFhex) Bits 5 ... 13: reserved Bit 14: extended device information Bit 15: reserved Delete inactive configuration frames from the configuration directory Start or end the parameterization phase Control statistical diagnostics Send control commands to local bus device Device_Function: 0003hex: Conf_Dev_Err 0004hex: Conf_Dev_Err_All Read status of local bus devices Device_State_Mask: Bits 0 ... 10: reserved Bit 11: peripheral fault Bits 12 ... 15: reserved Request additional error information Configure controller board without software support - Permitted addresses: 0000hex ... 03FFhex - No overlapping or duplication possible - Modules up to max. 8 bits with Byte-Cons at every address, modules > 8 bits only at even addresses Read address lists of the control or computer system that were configured using the “Compact_Load_Process_Data_Reference_List” service (3028hex) Read version information Read local bus counter Read system parameter Supported values for the Variable_ID parameter: see next table Start data transfer Stop data transfer PHOENIX CONTACT 16 / 18 AXC F IL ADAPT Code (hex) 0710 0711 Service Create_Configuration Activate_Configuration 0712 0713 Deactivate_Configuration Control_Active_Configuration 0714 Control_Device_Function 0750 Set_Value 0760 1303 Confirm_Diagnostics Alarm_Stop Description Read the connected bus Check the configuration frame matches the connected bus and whether addresses overlap Deactivate configuration frame Switch INTERBUS device on or off. Only Switch_Codes 0004hex (Device_Disable) and 0005hex (Device_Enable) are supported. Switching or bridging has no influence on the position of the process data in the memory or the CR assignment of the PCP devices. Send control commands to local bus device Device_Function: 0003hex: Conf_Dev_Err 0004hex: Conf_Dev_Err_All Assign new values to system parameters Supported values for the Variable_ID parameter: see next table Update diagnostic display and diagnostic register Reset local bus Supported values for the Variable_ID parameter Variable_ID (hex) 0101 0104 0105 010D 2200 2204 2210 2211 2212 2216 2218 A228 108629_en_00 System parameter Value/note State of the system management Contents of the diagnostic status register Contents of the diagnostic parameter register Contents of the extended diagnostic parameter register Operating mode Read access only Read access only Read access only Read access only 0000 0000hex: asynchronous 0600 0000hex: asynchronous with synchronization pulse Control the behavior of the input data in the event of a 0: input data in the MPM is frozen (default setting) bus error 1: input data in the MPM is set to zero Specified process data cycle time in s (32-bit value) Permissible value range: 0000 0000hex: off 0000 0100hex ... 0001 FB00hex Bus timeout in s (32-bit value) Permissible value: Default setting: 200 ms 0000 0000hex: (default setting) Bus warning time in s (32-bit value) Permissible value range: Default setting: 0 (not activated) 0000 00100hex ... 000F FF00hex Actual process data cycle time in s (32-bit value) Read access only Data cycle time in s (32-bit value) Read access only Read baud rate Read access only 0: 2 Mbaud 1: 500 kBaud PHOENIX CONTACT 17 / 18 AXC F IL ADAPT 13 PCP communication The Inline adapter terminal (INTERBUS master) supports the Peripherals Communication Protocol (PCP) Version 2.0 with Peripherals Message Specification (PMS). Peripherals Network Management 7 (PNM7) services are not supported. For information on PCP communication, please refer to the PCP user manuals (see Ordering data). Code (hex) 0081 4081 C081 8081 0082 4082 C082 8082 0885 4885 0086 8086 0087 8087 008B 408B C08B 808B 088D 488D 488E 0264 8264 Service Read_Request Read_Indication Read_Response Read_Confirmation Write_Request Write_Indication Write_Response Write_Confirmation Information_Report_Request Information_Report_Indication Status_Request Status_Confirmation Identify_Request Identify_Confirmation Initiate_Request Initiate_Indication Initiate_Response Initiate_Confirmation Abort_Request Abort_Indication Reject_Indication Load_CRL_Attribute_Loc_Request Load_CRL_Attribute_Loc_Confirmation 108629_en_00 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com 18 / 18
1020304 价格&库存

很抱歉,暂时无法提供与“1020304”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1020304
  •  国内价格 香港价格
  • 1+3190.036761+399.64325

库存:7