Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection
technology: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection:
IP20, including bus base module and Axioline F connectors
Product description
The module is designed for use within an Axioline F station. It is used to output digital signals. The outputs are protected against short circuit and
overload.
Your advantages
• 16 digital outputs
• 24 V DC, 500 mA
• Connection of actuators in 2-conductor technology
• Single-channel diagnostics
• Minimum update time of < 100 μs
• Device rating plate stored
Commercial data
Item number
1027904
Packing unit
1 pc
Minimum order quantity
1 pc
Sales key
DR02
Product key
DRI232
Catalog page
Page 77 (C-6-2019)
GTIN
4055626523767
Weight per piece (including packing)
212.8 g
Weight per piece (excluding packing)
212.8 g
Customs tariff number
85389091
Country of origin
DE
Jan 8, 2024, 9:41 AM
Page 1 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Technical data
Dimensions
Dimensional drawing
Width
35 mm
Height
129.9 mm
Depth
54 mm
Note on dimensions
The depth applies when a TH 35-7.5 DIN rail is used (in
accordance with EN 60715).
Interfaces
Axioline F local bus
Number of interfaces
2
Connection method
Bus base module
Transmission speed
100 Mbps
System properties
Module
Input address area
0 Byte
Output address area
2 Byte
Required parameter data
1 Byte
Required configuration data
6 Byte
Output data
Digital
Output name
Digital outputs
Connection method
Push-in connection
Connection technology
2-conductor
Number of outputs
16
Protective circuit
Short-circuit protection, overload protection of the outputs;
electronic
Output voltage
24 V DC
Limitation of the voltage induced on circuit interruption
-32.8 V ... -15 V
Maximum output current per module
8 A (provide external protection)
Nominal output voltage
24 V DC
Load min.
10 kΩ
Output voltage when switched off
max. 1 V
Jan 8, 2024, 9:41 AM
Page 2 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Output current when switched off
max. 300 µA
Nominal load, inductive
max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp
max. 12 W (at nominal voltage)
Nominal load, ohmic
max. 12 W (48 Ω, with nominal voltage)
Switching frequency
max. 10000 per second (with at least 50 mA load current)
max. 1 per second (with inductive load)
max. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulses
limited protection up to 0.5 A for 1 s
Behavior with overload
Shutdown with automatic restart
Behavior with inductive overload
Output can be destroyed
Signal delay
max. 100 µs (when switched on)
max. 100 µs (when switched off, with at least 50 mA load current)
Overcurrent shut-down
as of 0.7 A
Output current with ground connection interrupt when switched
off
< 1 mA
Product properties
Type
block modular
Product type
I/O component
Product family
Axioline F
Mounting position
any (no temperature derating)
Scope of delivery
including bus base module and Axioline F connectors
Insulation characteristics
Overvoltage category
II (IEC 60664-1, EN 60664-1)
Pollution degree
2 (IEC 60664-1, EN 60664-1)
Electrical properties
Maximum power dissipation for nominal condition
1.6 W
Potentials: Axioline F local bus supply (UBus)
Supply voltage
5 V DC (via bus base module)
Current draw
max. 60 mA
Power consumption
max. 300 mW
Potentials: Supply for digital output modules (UO)
Supply voltage
24 V DC
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
max. 8 A (provide external protection)
Power consumption
max. 240 W (of which 1.3 W constitute internal losses)
Protective circuit
Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode; with external 5 A fuse
(only for commissioning)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply
(I/Os)
500 V AC, 50 Hz, 1 min.
Jan 8, 2024, 9:41 AM
Page 3 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Test voltage: 5 V supply of the local bus (UBus) / functional
ground
500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground
500 V AC, 50 Hz, 1 min.
Connection data
Connection technology
Connection name
Axioline F connector
Note on the connection method
Please observe the information provided on conductor cross
sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection method
Push-in connection
Conductor cross section rigid
0.2 mm² ... 1.5 mm²
Conductor cross section flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Stripping length
8 mm
Axioline F connector
Connection method
Push-in connection
Note on the connection method
Please observe the information provided on conductor cross
sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid
0.2 mm² ... 1.5 mm²
Conductor cross section, flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Stripping length
8 mm
Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
5 % ... 95 % (non-condensing)
Standards and regulations
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting
Mounting type
DIN rail mounting
Mounting position
any (no temperature derating)
Jan 8, 2024, 9:41 AM
Page 4 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Drawings
Block diagram
OUT09 ... 16
40
41
62
63
Output circuit
41
40
40
UBus
41
62
63
C
Local bus
FE
2x
D
UO
E1
E2
00
01
22
23
00
01
FE
Output circuit
00
UO
01
22
23
OUT01 ... 08
24 V
Internal wiring of the terminal points
Jan 8, 2024, 9:41 AM
Page 5 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Energy consumption [J]
Diagram
0,4
Only with external free running circuit
0,35
0,3
0,25
0,2
0,15
0,1
1
1 = 0,5 A
2 = 0,4 A
3 = 0,3 A
4 = 0,2 A
5 = 0,1 A
2
3
4
0,05
0
5
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,4
Inductance [H]
Maximum outputs power consumption when inductive loads are switched off
Connection diagram
70
71
72
73
OUT13
OUT16
60
61
62
63
50
51
52
53
OUT09
OUT12
40
OUT01
41
42
43
00
01
02
03
10
11
12
13
20
21
22
23
30
31
32
33
OUT04
OUT08
Connection in 2-conductor technology
Jan 8, 2024, 9:41 AM
Page 6 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Dimensional drawing
129,9
54
122,4
35
Connection diagram
OUT01
00
01
02
03
10
11
12
13
20
21
22
23
30
31
32
33
OUT04
OUT08
Jan 8, 2024, 9:41 AM
Page 7 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1027904
DNV GL
Approval ID: TAA00000DF
LR
Approval ID: LR2001902TA-08
BV
PRS
NK
Approval ID: 14A006
Approval ID: 36433/B4 BV
Approval ID: TE/1020/880590/21
BSH
Approval ID: 840
RINA
Approval ID: ELE008423XG
ABS
Approval ID: 23-2449604-PDA
Functional Safety
Approval ID: 968/EL 711.05/16
UAE-RoHS
Approval ID: 23-02-63242
cULus Listed
Approval ID: E238705
Jan 8, 2024, 9:41 AM
Page 8 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Classifications
ECLASS
ECLASS-11.0
27242604
ECLASS-12.0
27242604
ECLASS-13.0
27242604
ETIM
ETIM 9.0
EC001599
UNSPSC
UNSPSC 21.0
32151600
Jan 8, 2024, 9:41 AM
Page 9 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Environmental product compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the
manufacturer’s declaration available under “Downloads”
Jan 8, 2024, 9:41 AM
Page 10 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
Accessories
AXL F BS H - Bus connector
2700992
https://www.phoenixcontact.com/us/products/2700992
Axioline F bus base module for housing type H
ZB 20,3 AXL UNPRINTED - Zack marker strip
0829579
https://www.phoenixcontact.com/us/products/0829579
Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch,
unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMSP1-PLOTTER
Jan 8, 2024, 9:41 AM
Page 11 (12)
AXL F DO16/2 2H - Digital module
1027904
https://www.phoenixcontact.com/us/products/1027904
ZBF 10/5,8 AXL UNPRINTED - Zack Marker strip, flat
0829580
https://www.phoenixcontact.com/us/products/0829580
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK,
CMS-P1-PLOTTER, mounting type: snapped, for terminal block width: 10.15
mm, lettering field size: 4 x 10, 15 x 5 mm, 1 x 5.8 x 5 mm, Number of individual
labels: 50
Phoenix Contact 2024 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Jan 8, 2024, 9:41 AM
Page 12 (12)