0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1027904

1027904

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    输入,输出(I/O)模块 DIN 轨道 24VDC

  • 数据手册
  • 价格&库存
1027904 数据手册
AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors Product description The module is designed for use within an Axioline F station. It is used to output digital signals. The outputs are protected against short circuit and overload. Your advantages • 16 digital outputs • 24 V DC, 500 mA • Connection of actuators in 2-conductor technology • Single-channel diagnostics • Minimum update time of < 100 μs • Device rating plate stored Commercial data Item number 1027904 Packing unit 1 pc Minimum order quantity 1 pc Sales key DR02 Product key DRI232 Catalog page Page 77 (C-6-2019) GTIN 4055626523767 Weight per piece (including packing) 212.8 g Weight per piece (excluding packing) 212.8 g Customs tariff number 85389091 Country of origin DE Jan 8, 2024, 9:41 AM Page 1 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Technical data Dimensions Dimensional drawing Width 35 mm Height 129.9 mm Depth 54 mm Note on dimensions The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). Interfaces Axioline F local bus Number of interfaces 2 Connection method Bus base module Transmission speed 100 Mbps System properties Module Input address area 0 Byte Output address area 2 Byte Required parameter data 1 Byte Required configuration data 6 Byte Output data Digital Output name Digital outputs Connection method Push-in connection Connection technology 2-conductor Number of outputs 16 Protective circuit Short-circuit protection, overload protection of the outputs; electronic Output voltage 24 V DC Limitation of the voltage induced on circuit interruption -32.8 V ... -15 V Maximum output current per module 8 A (provide external protection) Nominal output voltage 24 V DC Load min. 10 kΩ Output voltage when switched off max. 1 V Jan 8, 2024, 9:41 AM Page 2 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Output current when switched off max. 300 µA Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage) Nominal load, lamp max. 12 W (at nominal voltage) Nominal load, ohmic max. 12 W (48 Ω, with nominal voltage) Switching frequency max. 10000 per second (with at least 50 mA load current) max. 1 per second (with inductive load) max. 16 per second (with nominal lamp load) Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s Behavior with overload Shutdown with automatic restart Behavior with inductive overload Output can be destroyed Signal delay max. 100 µs (when switched on) max. 100 µs (when switched off, with at least 50 mA load current) Overcurrent shut-down as of 0.7 A Output current with ground connection interrupt when switched off < 1 mA Product properties Type block modular Product type I/O component Product family Axioline F Mounting position any (no temperature derating) Scope of delivery including bus base module and Axioline F connectors Insulation characteristics Overvoltage category II (IEC 60664-1, EN 60664-1) Pollution degree 2 (IEC 60664-1, EN 60664-1) Electrical properties Maximum power dissipation for nominal condition 1.6 W Potentials: Axioline F local bus supply (UBus) Supply voltage 5 V DC (via bus base module) Current draw max. 60 mA Power consumption max. 300 mW Potentials: Supply for digital output modules (UO) Supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple) Current draw max. 8 A (provide external protection) Power consumption max. 240 W (of which 1.3 W constitute internal losses) Protective circuit Surge protection; electronic (35 V, 0.5 s) Reverse polarity protection; parallel diode; with external 5 A fuse (only for commissioning) Electrical isolation/isolation of the voltage ranges Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC, 50 Hz, 1 min. Jan 8, 2024, 9:41 AM Page 3 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Test voltage: 5 V supply of the local bus (UBus) / functional ground 500 V AC, 50 Hz, 1 min. Test voltage: 24 V supply (I/O) / functional ground 500 V AC, 50 Hz, 1 min. Connection data Connection technology Connection name Axioline F connector Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Conductor connection Connection method Push-in connection Conductor cross section rigid 0.2 mm² ... 1.5 mm² Conductor cross section flexible 0.2 mm² ... 1.5 mm² Conductor cross section AWG 24 ... 16 Stripping length 8 mm Axioline F connector Connection method Push-in connection Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. Conductor cross section, rigid 0.2 mm² ... 1.5 mm² Conductor cross section, flexible 0.2 mm² ... 1.5 mm² Conductor cross section AWG 24 ... 16 Stripping length 8 mm Environmental and real-life conditions Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Degree of protection IP20 Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 5 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing) Standards and regulations Protection class III (IEC 61140, EN 61140, VDE 0140-1) Mounting Mounting type DIN rail mounting Mounting position any (no temperature derating) Jan 8, 2024, 9:41 AM Page 4 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Drawings Block diagram OUT09 ... 16 40 41 62 63 Output circuit 41 40 40 UBus 41 62 63 C Local bus FE 2x D UO E1 E2 00 01 22 23 00 01 FE Output circuit 00 UO 01 22 23 OUT01 ... 08 24 V Internal wiring of the terminal points Jan 8, 2024, 9:41 AM Page 5 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Energy consumption [J] Diagram 0,4 Only with external free running circuit 0,35 0,3 0,25 0,2 0,15 0,1 1 1 = 0,5 A 2 = 0,4 A 3 = 0,3 A 4 = 0,2 A 5 = 0,1 A 2 3 4 0,05 0 5 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0 2,1 2,2 2,3 2,4 Inductance [H] Maximum outputs power consumption when inductive loads are switched off Connection diagram 70 71 72 73 OUT13 OUT16 60 61 62 63 50 51 52 53 OUT09 OUT12 40 OUT01 41 42 43 00 01 02 03 10 11 12 13 20 21 22 23 30 31 32 33 OUT04 OUT08 Connection in 2-conductor technology Jan 8, 2024, 9:41 AM Page 6 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Dimensional drawing 129,9 54 122,4 35 Connection diagram OUT01 00 01 02 03 10 11 12 13 20 21 22 23 30 31 32 33 OUT04 OUT08 Jan 8, 2024, 9:41 AM Page 7 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1027904 DNV GL  Approval ID: TAA00000DF LR  Approval ID: LR2001902TA-08   BV  PRS NK Approval ID: 14A006 Approval ID: 36433/B4 BV Approval ID: TE/1020/880590/21 BSH Approval ID: 840  RINA Approval ID: ELE008423XG ABS Approval ID: 23-2449604-PDA Functional Safety Approval ID: 968/EL 711.05/16 UAE-RoHS Approval ID: 23-02-63242  cULus Listed Approval ID: E238705 Jan 8, 2024, 9:41 AM Page 8 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Classifications ECLASS ECLASS-11.0 27242604 ECLASS-12.0 27242604 ECLASS-13.0 27242604 ETIM ETIM 9.0 EC001599 UNSPSC UNSPSC 21.0 32151600 Jan 8, 2024, 9:41 AM Page 9 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Environmental product compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Jan 8, 2024, 9:41 AM Page 10 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 Accessories AXL F BS H - Bus connector 2700992 https://www.phoenixcontact.com/us/products/2700992 Axioline F bus base module for housing type H ZB 20,3 AXL UNPRINTED - Zack marker strip 0829579 https://www.phoenixcontact.com/us/products/0829579 Zack marker strip for Axioline F (device labeling), in 2 x 20.3 mm pitch, unprinted, 25-section, for individual labeling with B-STIFT 0.8, X-PEN, or CMSP1-PLOTTER Jan 8, 2024, 9:41 AM Page 11 (12) AXL F DO16/2 2H - Digital module 1027904 https://www.phoenixcontact.com/us/products/1027904 ZBF 10/5,8 AXL UNPRINTED - Zack Marker strip, flat 0829580 https://www.phoenixcontact.com/us/products/0829580 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snapped, for terminal block width: 10.15 mm, lettering field size: 4 x 10, 15 x 5 mm, 1 x 5.8 x 5 mm, Number of individual labels: 50 Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:41 AM Page 12 (12)
1027904 价格&库存

很抱歉,暂时无法提供与“1027904”相匹配的价格&库存,您可以联系我们找货

免费人工找货