Quick Start Guide
This Quick Start guide is valid for:
PDR-1000 (Order No. 1041980)
MNR 1095666
DNR 01169622_00
General information
User group of this manual
The use of products described in this manual is oriented exclusively to
qualified electricians or persons instructed by them, who are familiar with
applicable standards and other regulations regarding electrical engineering and, in particular, the relevant safety concepts.
Phoenix Contact accepts no liability for erroneous handling or damage to
products from Phoenix Contact or third-party products resulting from
disregard of information contained in this manual.
Explanation of symbols used and signal words
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.
DANGER
This indicates a hazardous situation which, if not avoided, will
result in death or serious injury
WARNING
This indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
This indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
The following types of messages provide information about possible property damage and general information concerning proper operation and
ease-of-use.
NOTE
This symbol and the accompanying text alerts the reader to a
situation which may cause damage or malfunction to the device,
either hardware or software, or surrounding property.
i
PHOENIX CONTACT
4010_en_C
This symbol and the accompanying text provides additional
information to the reader. It is also used as a reference to other
sources of information (manuals, data sheets, literature) on the
subject matter, product, etc.
General terms and conditions of use for technical
documentation
Phoenix Contact reserves the right to alter, correct, and/or improve the
technical documentation and the products described in the technical documentation at its own discretion and without giving prior notice, insofar as
this is reasonable for the user. The same applies to any technical changes
that serve the purpose of technical progress.
The receipt of technical documentation (in particular data sheets, installation instructions, manuals, etc.) does not constitute any further duty on the
part of Phoenix Contact to furnish information on alterations to products
and/or technical documentation. Any other agreement shall only apply if
expressly confirmed in writing by Phoenix Contact. Please note that the
supplied documentation is product-specific documentation only and that
you are responsible for checking the suitability and intended use of the
products in your specific application, in particular with regard to observing
the applicable standards and regulations.
Although Phoenix Contact makes every effort to ensure that the information content is accurate, up-to-date, and state-of-the-art, technical inaccuracies and/or printing errors in the information cannot be ruled out.
Phoenix Contact does not offer any guarantees as to the reliability, accuracy or completeness of the information. All information made available in
the technical data is supplied without any accompanying guarantee,
whether expressly mentioned, implied or tacitly assumed. This information does not include any guarantees regarding quality, does not describe
any fair marketable quality, and does not make any claims as to quality
guarantees or guarantees regarding the suitability for a special purpose.
Phoenix Contact accepts no liability or responsibility for errors or omissions in the content of the technical documentation (in particular data
sheets, installation instructions, manuals, etc.).
The aforementioned limitations of liability and exemptions from liability do
not apply, in so far as liability must be assumed, e.g., according to product
liability law, in cases of premeditation, gross negligence, on account of
loss of life, physical injury or damage to health or on account of the viola4010_en_C
PHOENIX CONTACT
ii
tion of important contractual obligations. Claims for damages for the violation of important contractual obligations are, however, limited to contracttypical, predictable damages, provided there is no premeditation or gross
negligence, or that liability is assumed on account of loss of life, physical
injury or damage to health. This ruling does not imply a change in the burden of proof to the detriment of the user.
Statement of legal authority
This manual, including all illustrations contained herein, is copyright protected. Use of this manual by any third party is forbidden. Reproduction,
translation, and public disclosure, as well as electronic and photographic
archiving or alteration requires the express written consent
of Phoenix Contact. Violators are liable for damages.
Phoenix Contact reserves all rights in the case of patent award or listing of
a registered design. Third-party products are always named without reference to patent rights. The existence of such rights shall not be excluded.
How to contact us
Internet
Up-to-date information on Phoenix Contact products and our Terms and
Conditions can be found on the Internet at:
phoenixcontact.com.
Subsidiaries
If there are any problems that cannot be solved using the documentation,
please contact your Phoenix Contact subsidiary.
Subsidiary contact information is available at www.phoenixcontact.com.
Published by
PHOENIX CONTACT
P.O. Box 4100
Harrisburg, PA 17111-0100
USA
Telephone +1-717-944-1300
Should you have any suggestions or recommendations for improvement
of the contents and layout of our manuals, please send your comments to
tecdoc@phoenixcontact.com.
iii
PHOENIX CONTACT
4010_en_C
Device power-up
Wiring the controller
Refer to the documentation provided with the ILC 191 ETH 2TX controller
(Order no. 2700976) for installation instructions.
Information for the ILC 191 ETH 2TX can be found at
phoenixcontact.net/product/2700976
Installing the input modules
WARNING:
Always remove power from the device before installation or
removal of modules.
Up to ten modules can be used on the bus at a time. The following
modules are applicable for this application:
Table 1
Available modules
Order No.
Descriptor
Provides
2861302
IB IL AI 2/SF-PAC
Two analog channels
2861386
IB IL TEMP 2 UTH-PAC
Two thermocouple channels
2861328
IB IL TEMP 2 RTD-PAC
Two RTD channels
2700173
IB IL 24 DI8/HD-PAC
Eight digital inputs
2700172
IB IL 24 DO8/HD-PAC
Eight digital outputs
Refer to the individual module documentation for wiring instructions to
field devices.
1
PHOENIX CONTACT
4010_en_C
SD flash card memory
The PDR-1000 includes a pre-installed 2 GB SD card required for
operation.
Only Phoenix Contact 2 GB cards are supported.
4010_en_C
PHOENIX CONTACT
2
Connecting the user interface
1.
2.
Connect an Ethernet cable between an RJ45 port on the ILC 191
ETH 2TX controller and a computer.
Set the IP address of the computer to 192.168.0.100 or any unused
IP address in 192.168.x.x subnet with a subnet mask of
255.255.255.0.
Figure 1
3
“Ethernet 2 Properties” dialog box
PHOENIX CONTACT
4010_en_C
Figure 2
4010_en_C
“Internet Protocol Version 4 (TCP/IPv4) Properties” dialog box
PHOENIX CONTACT
4
3.
Open a browser (Google Chrome™ or Mozilla® Firefox® are
recommended) and enter http://192.168.0.5 in the “Address” field to
load the user interface.
Figure 3
Initial connection loading screen
The loading screen will display with the application is loaded. This
may take some time, depending on the network connection.
5
PHOENIX CONTACT
4010_en_C
Configuring the connected modules
The first time connecting to the device will cause a prompt to configure the
hardware setup to match the physical arrangement of modules.
Figure 4
Hardware configuration
Click on each module, and click the appropriate module from the list to
select it. Click the “Save” button when finished.
4010_en_C
PHOENIX CONTACT
6
Accessing the administrative settings
The I/O channels, channel groupings, and recorded I/O list must be
configured before logging can begin.
1. Click the “Configuration” button in the top right corner of the screen.
Configuration button
Figure 5
2.
3.
7
Configuration button on the Dashboard
Enter the administrative credentials in the pop-up window. The
default password is private.
Navigate to the I/O Configuration page and enter the I/O data as
desired.
PHOENIX CONTACT
4010_en_C