0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1050206

1050206

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    聚碳酸脂(PC) 基座 灰色

  • 数据手册
  • 价格&库存
1050206 数据手册
ECS... Electronic enclosures Data sheet 3778_en_A 1 © PHOENIX CONTACT 2018-04-26 Description The Environmental Case System (ECS) is an enclosure system to protect devices from the elements in outdoor or indoor applications. The ECS... product line consists of a base and faceplate that are combined to make a complete enclosure system. The enclosure is available in two different locking methods: screw and mechanical latch. Both locking methods are available with or without a breather vent to alleviate pressure buildup when the enclosure is sealed and reduce condensation formation. Faceplates are available with a variety of connectors to meet various application requirements. A blank faceplate is available that can be customized to meet virtually any connector configuration. Wall, machine, and pole-mounting options allow flexibility for different applications. 3D housing data can be found at phoenixcontact.net/products. Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products. This document is valid for all products listed in the “Ordering data” on page 4 ECS... Table of contents 1 Description.................................................................................................................................. 1 2 Overview of the ECS... products ................................................................................................. 3 3 Ordering data.............................................................................................................................. 4 4 Technical data ............................................................................................................................ 4 5 Dimensions................................................................................................................................. 5 5.1 5.2 5.3 6 Connection technology ............................................................................................................... 8 6.1 6.2 6.3 7 External .......................................................................................................................................................... 5 Internal ........................................................................................................................................................... 6 PCB dimensions............................................................................................................................................. 7 ECS-P...B faceplate ....................................................................................................................................... 8 ECS-P...M12 faceplate................................................................................................................................... 8 ECS-P...CG faceplate .................................................................................................................................... 9 Installation .................................................................................................................................. 9 7.1 7.2 7.3 7.4 3778_en_A Printed circuit board to faceplate assembly .................................................................................................... 9 Board lock (optional) ...................................................................................................................................... 9 Faceplate and base...................................................................................................................................... 10 Mounting ...................................................................................................................................................... 11 PHOENIX CONTACT 2/12 ECS... 2 Overview of the ECS... products 7 1 6 4 5 3 2 1 2 3 4 Figure 1 Base Faceplate Connector area Mounting foot 5 6 7 Locking mechanism (screw shown) Alignment tabs Label area Typical ECS... assembly (screw latch shown) The faceplate is available as a blank, with one or two M12 connectors, or a cable gland. The ECS... system provides two locking methods to secure the faceplate to the base. – Mechanical latch: No tools are required to secure the faceplate to the base, but a flat blade screwdriver is required to release the faceplate for removal. – Screw latch: Faceplate is secured to the base using screws that accept either a flat screwdriver or T20 Torx® driver. 3778_en_A PHOENIX CONTACT 3/12 ECS... 3 Ordering data Products Description Type Order No. Base, mechanical latch, vented, black ECS-B-122X169-L-UV1-V 2230000 5 Base, mechanical latch, non-vented, black ECS-B-122X169-L-UV1-NV 2230001 5 Base, screw latch, vented, black ECS-B-122X169-S-UV1-V 2230002 5 Base, screw latch, non-vented, black ECS-B-122X169-S-UV1-NV 2230003 5 Pcs./Pkt. Faceplate, mechanical latch, blank, black ECS-P-122X169-L-UV1-B 2230004 5 Faceplate, mechanical latch, one M12 connector, black ECS-P-122X169-L-UV1-1M12 2230005 5 Faceplate, mechanical latch, two M12 connectors, black ECS-P-122X169-L-UV1-2M12 2230006 5 Faceplate, mechanical latch, one cable gland, black ECS-P-122X169-L-UV1-CG 2230007 5 Faceplate, screw latch, blank, black ECS-P-122X169-S-UV1-B 2230008 5 Faceplate, screw latch, one M12 connector, black ECS-P-122X169-S-UV1-1M12 2230009 5 Faceplate, screw latch, two M12 connectors, black ECS-P-122X169-S-UV1-2M12 2230010 5 Faceplate, screw latch, one cable gland, black ECS-P-122X169-S-UV1-CG 2230011 5 Base, mechanical latch, vented, gray ECS-B-122X169-L-UV-V GY 1050206 5 Base, mechanical latch, non-vented, gray ECS-B-122X169-L-UV-NV GY 1050212 5 Base, screw latch, vented, gray ECS-B-122X169-S-UV-V GY 1050209 5 Base, screw latch, non-vented, gray ECS-B-122X169-S-UV-NV GY 1050207 5 Faceplate, mechanical latch, blank, gray ECS-P-122X169-L-UV-B GY 1050386 5 Faceplate, mechanical latch, one M12 connector, gray ECS-P-122X169-L-UV-1M12 GY 1050385 5 Faceplate, mechanical latch, two M12 connectors, gray ECS-P-122X169-L-UV-2M12 GY 1050384 5 Faceplate, mechanical latch, one cable gland, gray ECS-P-122X169-L-UV-CG GY 1050383 5 Faceplate, screw latch, blank, gray ECS-P-122X169-S-UV-B GY 1050382 5 Faceplate, screw latch, one M12 connector, gray ECS-P-122X169-S-UV-1M12 GY 1050381 5 Faceplate, screw latch, two M12 connectors, gray ECS-P-122X169-S-UV-2M12 GY 1050379 5 Faceplate, screw latch, one cable gland, gray ECS-P-122X169-S-UV-CG GY 1050380 5 Accessories Description Type Order No. Pcs./Pkt. Board lock ECS-BL 2230012 10 Pole-mounting kit ECS-PM 2230013 1 4 Technical data General data Ambient temperature, operating -40...85°C Ambient temperature, storage -40...85°C UL 94 flammability rating V0 Material Polycarbonate Color Black Power dissipation, Pv, at 20°C (horizontal mounting position) 19 W Degree of protection IP66/67/69 NEMA 250 enclosure rating 6 3778_en_A PHOENIX CONTACT 4/12 ECS... Conformance UL 736C (Outdoor suitability) f1 UL 50/50E UL enclosure type1 4, 4X, 6 IEC 60068 (Vibration) 15g: 10-2000-10 Hz X, Y, Z for 2.5 h IEC 60068 (Shock) 50g, 20 pulses EN 50102 (Impact) IK08 IEC 60068 (Salt fog) 96 h Enclosure components must be sold as a kit to apply mark. Contact local sales office for information. 5 Dimensions 5.1 External 148 180 A 180 110 110 148 164 64 64 196 161 161 Model ECS-P-…-L-…1M12 (GY) ECS-P-…-L-…2M12 (GY) ECS-P-…-L-…CG (GY) ECS-P-…-L-…B (GY) Figure 2 3778_en_A A 1 Dimension “A” 186 mm 186 mm 206 mm 176 mm ECS...L... dimensions Model ECS-P-…-S-…1M12 (GY) ECS-P-…-S-…2M12 (GY) ECS-P-…-S-…CG (GY) ECS-P-…-L-…B (GY) Figure 3 Dimension “A” 186 mm 186 mm 206 mm 176 mm ECS...S... dimensions PHOENIX CONTACT 5/12 ECS... 5.2 Internal C C B B A A F F E E D D 121.52 91.13 91.13 117.9 117.9 7.57 30.11 7.57 29.32 121.52 D-D 113.13 C-C Figure 4 3778_en_A 113.13 E-E 27.56 Inside view of enclosure 1.59 mm board F-F Figure 5 4.57 7.86 9.29 30.63 3.75 7.67 9.06 12.23 100.23 99.97 31.22 12.88 B-B 10.62 10.62 32.67 31.88 A-A 22.48 Inside view of enclosure 2.36 mm board PHOENIX CONTACT 6/12 ECS... 5.3 PCB dimensions 121.0±0.3 Component/Trace keep-out zone 109.0±0.3 92.0±0.3 10° Maximum component height – Above PCB (1.57 mm PCB) = 12.5 mm – Above PCB (2.36 mm PCB) = 11.5 mm – Below PCB = 7.5 mm 25.4±0.3 128.2±0.3 2X R15.0±0.3 Maximum component height – Above PCB (1.57 mm PCB) = 30.5 mm – Above PCB (2.36 mm PCB) = 11.5 mm – Below PCB = 3.5 mm 131.9±0.3 66.1±0.3 2X 92.6±0.3 E Detail 1 A Maximum component height – Above PCB (1.57 mm PCB) = 30.5 mm – Above PCB (2.36 mm PCB) = 11.5 mm – Below PCB = No trace or components A 9.2±0.3 ø5.32±0.15 2X D 87.0±0.3 14.45±0.3 2X 91.0±0.3 104.0±0.3 Maximum component height – Above PCB = 29.5 mm – Below PCB = 9.5 mm 1.97±0.15 2.0±0.3 B 7.4±0.3 Detail 1 2:1 A B C D Figure 6 3778_en_A PCB mounting hardware hole Optional cutout for ECS-BL (location and quantity determined by application) Faceplate PCB connections 1.57 mm PCB = 145.6 mm 2.36 mm PCB = 139.6 mm Circuit board design dimensions and restrictions PHOENIX CONTACT 7/12 ECS... 118.6 10.1 42.0 65 71.0 103 Figure 8 Available connector area for ECS-P...B The available connector area is the same for both the mechanical latch and screw-type faceplates. 6.2 ECS-P...M12 faceplate ECS-P...M12 faceplates provide either one or two M12 connectors. The M12 connector is a two-piece system with a nut and insert. An M12 female coupling nut (Order No. 1552243) is provided for installation during assembly. Figure 7 6 Label area Connection technology The ECS... enclosure provides for the use of any existing IP66/67 connection technology. 6.1 ECS-P...B faceplate The ECS-P...B faceplate is provided as a blank faceplate. It allows users to customize the faceplate to meet specific application requirements. – Add connector styles not currently available as a preconfigured faceplates from Phoenix Contact. – Combine connector styles for a specific application. For instance, combine two M12 connectors and one RJ45 connector. Designers must order inserts separately for each specific application. Some of the common inserts are: 1432444 1436628 1432457 1432431 1436644 1437009 1436990 1424199 1424195 1424201 1424197 1424193 1424180 SACC-CI-M12FS-4CON-L 90 SH SCO SACC-CI-M12FS-4CON-L90 SCO SACC-CI-M12FSD-4CON-L90 SCO SACC-CI-FS-5CON-L 90 SH SCO SACC-CI-M12FS-5CON-L90 SCO SACC-CI-M12FS-8CON-L90 SH SCO SACC-CI-M12FS-8CON-L90 SCO SACC-CI-M12FS-12CON-L90 SH SACC-CI-M12FS-12CON-L90 SACC-CI-M12FS-17CON-L90 SH SACC-CI-M12FS-17CON-L90 SACC-CI-M12FSY-8CON-L90 SACC-CI-M12FSX-8CON-L90 The ECS-P...B faceplate allows placement of connectors as desired within a certain area on the faceplate. The placement and number of connectors that can be added to the ECS-P…B (GY) is limited to within the area defined in Figure 8. 3778_en_A PHOENIX CONTACT 8/12 ECS... Installation 7 Installation 7.1 Printed circuit board to faceplate assembly 3 2 The printed circuit board must be secured to the faceplate before the faceplate is mated to the base. 1 Figure 9 For ECS-P...M12 faceplates, the M12 connector(s) must be installed on the faceplate prior to attaching the printed circuit board. 4 M12 connector installation 2 1. 2. 3. Position the connector housing (1) into the hole on the ECS-P...M12. Thread the nut (2) on the opposite side and torque to 1.5 to 2.0 Nm. Place the circuit board with the connector insert (3) into position on the ECS-P...M12 with the insert in the center of the connector housing. Secure the circuit board to the ECS-P...M12 (see 7.1 “Printed circuit board to faceplate assembly”). PC 5 3 4 1 Figure 10 Circuit board placement NOTE: Avoid all radial forces between the connector inserts attached to the circuit board and any connector housings in the faceplate. Axial forces
1050206 价格&库存

很抱歉,暂时无法提供与“1050206”相匹配的价格&库存,您可以联系我们找货

免费人工找货