ECS...
Electronic enclosures
Data sheet
3778_en_A
1
© PHOENIX CONTACT 2018-04-26
Description
The Environmental Case System (ECS) is an enclosure
system to protect devices from the elements in outdoor or
indoor applications. The ECS... product line consists of a
base and faceplate that are combined to make a complete
enclosure system.
The enclosure is available in two different locking methods:
screw and mechanical latch. Both locking methods are
available with or without a breather vent to alleviate
pressure buildup when the enclosure is sealed and reduce
condensation formation.
Faceplates are available with a variety of connectors to
meet various application requirements. A blank faceplate is
available that can be customized to meet virtually any
connector configuration.
Wall, machine, and pole-mounting options allow flexibility
for different applications.
3D housing data can be found at phoenixcontact.net/products.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.net/products.
This document is valid for all products listed in the “Ordering data” on page 4
ECS...
Table of contents
1
Description.................................................................................................................................. 1
2
Overview of the ECS... products ................................................................................................. 3
3
Ordering data.............................................................................................................................. 4
4
Technical data ............................................................................................................................ 4
5
Dimensions................................................................................................................................. 5
5.1
5.2
5.3
6
Connection technology ............................................................................................................... 8
6.1
6.2
6.3
7
External .......................................................................................................................................................... 5
Internal ........................................................................................................................................................... 6
PCB dimensions............................................................................................................................................. 7
ECS-P...B faceplate ....................................................................................................................................... 8
ECS-P...M12 faceplate................................................................................................................................... 8
ECS-P...CG faceplate .................................................................................................................................... 9
Installation .................................................................................................................................. 9
7.1
7.2
7.3
7.4
3778_en_A
Printed circuit board to faceplate assembly .................................................................................................... 9
Board lock (optional) ...................................................................................................................................... 9
Faceplate and base...................................................................................................................................... 10
Mounting ...................................................................................................................................................... 11
PHOENIX CONTACT
2/12
ECS...
2
Overview of the ECS... products
7
1
6
4
5
3
2
1
2
3
4
Figure 1
Base
Faceplate
Connector area
Mounting foot
5
6
7
Locking mechanism (screw shown)
Alignment tabs
Label area
Typical ECS... assembly (screw latch shown)
The faceplate is available as a blank, with one or two M12
connectors, or a cable gland.
The ECS... system provides two locking methods to secure
the faceplate to the base.
– Mechanical latch: No tools are required to secure the
faceplate to the base, but a flat blade screwdriver is
required to release the faceplate for removal.
– Screw latch: Faceplate is secured to the base using
screws that accept either a flat screwdriver or T20
Torx® driver.
3778_en_A
PHOENIX CONTACT
3/12
ECS...
3
Ordering data
Products
Description
Type
Order No.
Base, mechanical latch, vented, black
ECS-B-122X169-L-UV1-V
2230000
5
Base, mechanical latch, non-vented, black
ECS-B-122X169-L-UV1-NV
2230001
5
Base, screw latch, vented, black
ECS-B-122X169-S-UV1-V
2230002
5
Base, screw latch, non-vented, black
ECS-B-122X169-S-UV1-NV
2230003
5
Pcs./Pkt.
Faceplate, mechanical latch, blank, black
ECS-P-122X169-L-UV1-B
2230004
5
Faceplate, mechanical latch, one M12 connector, black
ECS-P-122X169-L-UV1-1M12
2230005
5
Faceplate, mechanical latch, two M12 connectors, black
ECS-P-122X169-L-UV1-2M12
2230006
5
Faceplate, mechanical latch, one cable gland, black
ECS-P-122X169-L-UV1-CG
2230007
5
Faceplate, screw latch, blank, black
ECS-P-122X169-S-UV1-B
2230008
5
Faceplate, screw latch, one M12 connector, black
ECS-P-122X169-S-UV1-1M12
2230009
5
Faceplate, screw latch, two M12 connectors, black
ECS-P-122X169-S-UV1-2M12
2230010
5
Faceplate, screw latch, one cable gland, black
ECS-P-122X169-S-UV1-CG
2230011
5
Base, mechanical latch, vented, gray
ECS-B-122X169-L-UV-V GY
1050206
5
Base, mechanical latch, non-vented, gray
ECS-B-122X169-L-UV-NV GY
1050212
5
Base, screw latch, vented, gray
ECS-B-122X169-S-UV-V GY
1050209
5
Base, screw latch, non-vented, gray
ECS-B-122X169-S-UV-NV GY
1050207
5
Faceplate, mechanical latch, blank, gray
ECS-P-122X169-L-UV-B GY
1050386
5
Faceplate, mechanical latch, one M12 connector, gray
ECS-P-122X169-L-UV-1M12 GY
1050385
5
Faceplate, mechanical latch, two M12 connectors, gray
ECS-P-122X169-L-UV-2M12 GY
1050384
5
Faceplate, mechanical latch, one cable gland, gray
ECS-P-122X169-L-UV-CG GY
1050383
5
Faceplate, screw latch, blank, gray
ECS-P-122X169-S-UV-B GY
1050382
5
Faceplate, screw latch, one M12 connector, gray
ECS-P-122X169-S-UV-1M12 GY
1050381
5
Faceplate, screw latch, two M12 connectors, gray
ECS-P-122X169-S-UV-2M12 GY
1050379
5
Faceplate, screw latch, one cable gland, gray
ECS-P-122X169-S-UV-CG GY
1050380
5
Accessories
Description
Type
Order No.
Pcs./Pkt.
Board lock
ECS-BL
2230012
10
Pole-mounting kit
ECS-PM
2230013
1
4
Technical data
General data
Ambient temperature, operating
-40...85°C
Ambient temperature, storage
-40...85°C
UL 94 flammability rating
V0
Material
Polycarbonate
Color
Black
Power dissipation, Pv, at 20°C (horizontal mounting position)
19 W
Degree of protection
IP66/67/69
NEMA 250 enclosure rating
6
3778_en_A
PHOENIX CONTACT
4/12
ECS...
Conformance
UL 736C (Outdoor suitability)
f1
UL 50/50E
UL enclosure type1
4, 4X, 6
IEC 60068 (Vibration)
15g: 10-2000-10 Hz X, Y, Z for 2.5 h
IEC 60068 (Shock)
50g, 20 pulses
EN 50102 (Impact)
IK08
IEC 60068 (Salt fog)
96 h
Enclosure components must be sold as a kit to apply mark. Contact local sales office for information.
5
Dimensions
5.1
External
148
180
A
180
110
110
148
164
64
64
196
161
161
Model
ECS-P-…-L-…1M12 (GY)
ECS-P-…-L-…2M12 (GY)
ECS-P-…-L-…CG (GY)
ECS-P-…-L-…B (GY)
Figure 2
3778_en_A
A
1
Dimension “A”
186 mm
186 mm
206 mm
176 mm
ECS...L... dimensions
Model
ECS-P-…-S-…1M12 (GY)
ECS-P-…-S-…2M12 (GY)
ECS-P-…-S-…CG (GY)
ECS-P-…-L-…B (GY)
Figure 3
Dimension “A”
186 mm
186 mm
206 mm
176 mm
ECS...S... dimensions
PHOENIX CONTACT
5/12
ECS...
5.2
Internal
C
C
B
B
A
A
F
F
E
E
D
D
121.52
91.13
91.13
117.9
117.9
7.57
30.11
7.57
29.32
121.52
D-D
113.13
C-C
Figure 4
3778_en_A
113.13
E-E
27.56
Inside view of enclosure 1.59 mm board
F-F
Figure 5
4.57
7.86
9.29
30.63
3.75
7.67
9.06
12.23
100.23
99.97
31.22
12.88
B-B
10.62
10.62
32.67
31.88
A-A
22.48
Inside view of enclosure 2.36 mm board
PHOENIX CONTACT
6/12
ECS...
5.3
PCB dimensions
121.0±0.3
Component/Trace keep-out zone
109.0±0.3
92.0±0.3
10°
Maximum component height
– Above PCB (1.57 mm PCB) = 12.5 mm
– Above PCB (2.36 mm PCB) = 11.5 mm
– Below PCB = 7.5 mm
25.4±0.3
128.2±0.3
2X
R15.0±0.3
Maximum component height
– Above PCB (1.57 mm PCB) = 30.5 mm
– Above PCB (2.36 mm PCB) = 11.5 mm
– Below PCB = 3.5 mm
131.9±0.3
66.1±0.3
2X 92.6±0.3
E
Detail 1
A
Maximum component height
– Above PCB (1.57 mm PCB) = 30.5 mm
– Above PCB (2.36 mm PCB) = 11.5 mm
– Below PCB = No trace or components
A
9.2±0.3
ø5.32±0.15
2X
D
87.0±0.3
14.45±0.3
2X
91.0±0.3
104.0±0.3
Maximum component height
– Above PCB = 29.5 mm
– Below PCB = 9.5 mm
1.97±0.15
2.0±0.3
B
7.4±0.3
Detail 1
2:1
A
B
C
D
Figure 6
3778_en_A
PCB mounting hardware hole
Optional cutout for ECS-BL (location and quantity
determined by application)
Faceplate PCB connections
1.57 mm PCB = 145.6 mm
2.36 mm PCB = 139.6 mm
Circuit board design dimensions and restrictions
PHOENIX CONTACT
7/12
ECS...
118.6
10.1
42.0
65
71.0
103
Figure 8
Available connector area for ECS-P...B
The available connector area is the same for both the
mechanical latch and screw-type faceplates.
6.2
ECS-P...M12 faceplate
ECS-P...M12 faceplates provide either one or two M12
connectors. The M12 connector is a two-piece system with
a nut and insert. An M12 female coupling nut (Order No.
1552243) is provided for installation during assembly.
Figure 7
6
Label area
Connection technology
The ECS... enclosure provides for the use of any existing
IP66/67 connection technology.
6.1
ECS-P...B faceplate
The ECS-P...B faceplate is provided as a blank faceplate. It
allows users to customize the faceplate to meet specific
application requirements.
– Add connector styles not currently available as a
preconfigured faceplates from Phoenix Contact.
– Combine connector styles for a specific application. For
instance, combine two M12 connectors and one RJ45
connector.
Designers must order inserts separately for each specific
application. Some of the common inserts are:
1432444
1436628
1432457
1432431
1436644
1437009
1436990
1424199
1424195
1424201
1424197
1424193
1424180
SACC-CI-M12FS-4CON-L 90 SH SCO
SACC-CI-M12FS-4CON-L90 SCO
SACC-CI-M12FSD-4CON-L90 SCO
SACC-CI-FS-5CON-L 90 SH SCO
SACC-CI-M12FS-5CON-L90 SCO
SACC-CI-M12FS-8CON-L90 SH SCO
SACC-CI-M12FS-8CON-L90 SCO
SACC-CI-M12FS-12CON-L90 SH
SACC-CI-M12FS-12CON-L90
SACC-CI-M12FS-17CON-L90 SH
SACC-CI-M12FS-17CON-L90
SACC-CI-M12FSY-8CON-L90
SACC-CI-M12FSX-8CON-L90
The ECS-P...B faceplate allows placement of connectors as
desired within a certain area on the faceplate. The
placement and number of connectors that can be added to
the ECS-P…B (GY) is limited to within the area defined in
Figure 8.
3778_en_A
PHOENIX CONTACT
8/12
ECS...
Installation
7
Installation
7.1
Printed circuit board to faceplate assembly
3
2
The printed circuit board must be secured to the faceplate
before the faceplate is mated to the base.
1
Figure 9
For ECS-P...M12 faceplates, the M12
connector(s) must be installed on the faceplate
prior to attaching the printed circuit board.
4
M12 connector installation
2
1.
2.
3.
Position the connector housing (1) into the hole on the
ECS-P...M12.
Thread the nut (2) on the opposite side and torque to
1.5 to 2.0 Nm.
Place the circuit board with the connector insert (3) into
position on the ECS-P...M12 with the insert in the center
of the connector housing. Secure the circuit board to
the ECS-P...M12 (see 7.1 “Printed circuit board to
faceplate assembly”).
PC
5
3 4
1
Figure 10
Circuit board placement
NOTE:
Avoid all radial forces between the connector
inserts attached to the circuit board and any
connector housings in the faceplate. Axial forces