0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1066716

1066716

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    QUINT4-PS/12-24DC/24DC/1.3/PT

  • 数据手册
  • 价格&库存
1066716 数据手册
QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, input: 12 V DC - 24 V DC, output: 24 V DC / 1.3 A Product description In the power range of up to 100 W, QUINT POWER provides superior system availability in the smallest size. Preventative function monitoring and exceptional power reserves are available for applications in the low-power range. Your advantages • Most powerful output side: easy system expansion, reliable heavy load startup and miniature circuit breaker tripping • Most comprehensive signaling: preventive function monitoring reports critical operating states before errors occur • Free selection between Push-in and screw connection Commercial data Item number 1066716 Packing unit 1 pc Minimum order quantity 1 pc Sales key CM01 Product key CMDI43 GTIN 4055626734262 Weight per piece (including packing) 221.866 g Weight per piece (excluding packing) 169 g Customs tariff number 85044095 Country of origin CN Jan 8, 2024, 9:27 AM Page 1 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Technical data Input data Nominal input voltage range 12 V DC ... 24 V DC Input voltage range 12 V DC ... 24 V DC -25 % ... +33 % (SELV) Wide-range input yes Electric strength, max. 35 V DC (60 s) Inrush current typ. 1.6 A 2 Inrush current integral (I t) typ. 0.1 A2s Inrush current limitation typ. 1.6 A Mains buffering time typ. 19 ms (24 V DC) Current consumption typ. 3.75 A (12 V DC) typ. 1.85 A (24 V DC) Typical response time 700 ms (from SLEEP MODE) Switch-on time 24 V DC, constant capacity) Nominal output current (IN) 1.3 A Static Boost (IStat.Boost) 1.625 A (≤ 40 °C) Dynamic Boost (IDyn.Boost) 2.6 A (≤ 60 °C (4.9 s)) Short-circuit-proof yes No-load proof yes Derating > 60 °C (2.5%/K of POut nom.) Output power (PN) 30 W Output power (PStat. Boost) 38 W Output power (PDyn. Boost) 60 W Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) < 32 V DC Residual ripple < 20 mVPP Control deviation < 1 % (change in load, static 10 % ... 90 %) Control deviation < 1 % (change in load, static 10 % ... 90 %) Control deviation < 1 % (change in load, static 10 % ... 90 %) Rise time < 1 s (UOUT (10 % ... 90 %)) Connection in series yes Maximum no-load power dissipation < 1.3 W Jan 8, 2024, 9:27 AM Page 2 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Power loss nominal load max.  0.9 x USet Connection data Input Position 1.x Conductor connection Connection method Push-in connection rigid 0.5 mm² ... 2.5 mm² flexible 0.5 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve 0.5 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve 0.25 mm² ... 2.5 mm² rigid (AWG) 22 ... 14 Stripping length 10 mm Output Position 2.x Conductor connection Connection method Push-in connection rigid 0.2 mm² ... 2.5 mm² flexible 0.25 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve 0.25 mm² ... 2.5 mm² rigid (AWG) 24 ... 14 Stripping length 10 mm Signal Position 3.x Conductor connection Connection method Push-in connection rigid 0.2 mm² ... 2.5 mm² flexible 0.2 mm² ... 2.5 mm² flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm² flexible with ferrule with plastic sleeve 0.25 mm² ... 2.5 mm² rigid (AWG) 24 ... 14 Jan 8, 2024, 9:27 AM Page 3 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Stripping length 10 mm Signaling LED signaling Signal threshold > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting) > 0.9 x USet (LED lights up green) < 0.9 x USet (LED flashes green) Electrical properties Number of phases 1.00 Insulation voltage input/output 2.6 kV DC (type test) 1.2 kV DC (routine test) Switching frequency 130 kHz ... 130 kHz (Auxiliary converter stage) 70 kHz ... 250 kHz (Main converter stage) Product properties Product type DC/DC converters Product family QUINT POWER MTBF (IEC 61709, SN 29500) > 1999348 h (25 °C) > 1120490 h (40 °C) > 471066 h (60 °C) Insulation characteristics Protection class II Degree of pollution 2 Life expectancy (electrolytic capacitors) Current 0.65 A Temperature 40 °C Time 242000 h Additional text 24 V DC Life expectancy (electrolytic capacitors) Current 1.3 A Temperature 40 °C Time 160000 h Additional text 24 V DC Life expectancy (electrolytic capacitors) Current 1.3 A Temperature 30 °C Time 320000 h Additional text 24 V DC Dimensions Jan 8, 2024, 9:27 AM Page 4 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Item dimensions Width 22.5 mm Height 106 mm Depth 90 mm Installation dimensions Installation distance right/left (active) 15 mm / 15 mm (POut ≥50% ) Installation distance right/left (passive) 5 mm / 5 mm (POut ≥50% ) Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %) Installation distance top/bottom (active) 30 mm / 30 mm (POut ≥50% ) Installation distance top/bottom (passive) 30 mm / 30 mm (POut ≥50% ) Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≤50 %) Mounting Mounting type DIN rail mounting Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN  60 °C Derating: 2,5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Ambient temperature (start-up type tested) -40 °C Maximum altitude ≤ 5000 m (> 2000 m, observe derating) Climatic class 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Shock 18 ms, 30g, in each space direction (according to IEC 60068-227) Vibration (operation) < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6) Standards and regulations Overvoltage category EN 61010-1 II (≤ 5000 m) Safety for measurement, control, and laboratory equipment Jan 8, 2024, 9:27 AM Page 5 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Standard designation Electrical safety (of control and regulation devices) Standards/specifications IEC 61010-1 Protective extra-low voltage Standard designation Protective extra-low voltage Standards/specifications IEC 61010-1 (SELV) Mains voltage dips Standard designation Mains variation/undervoltage Standards/specifications EN 61000-4-29 Approvals SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201) UL approvals UL Listed UL 61010-1 UL Listed UL 61010-2-201 ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) UL Identification UL Listed UL 61010-1 UL Identification CAN/CSA C22.2 No. 61010-1-12 UL Identification UL Listed UL 61010-2-201 UL Identification CAN/CSA C22.2 No. 61010-2-201:18 UL Identification UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) CB scheme Identification IEC 61010-1 CB scheme Identification IEC 61010-2-201 Shipbuilding Identification DNV GL EMC data EMC requirements for noise emission EN 61000-6-3 EN 61000-6-4 EMC requirements for noise immunity EN 61000-6-1 EN 61000-6-2 Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Jan 8, 2024, 9:27 AM Page 6 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 EMC requirements, power plant EN 61850-3 EN 61000-6-5 Conducted noise emission EN 55016 EN 61000-6-3 (Class B) Noise emission Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) Noise emission EN 55016 EN 61000-6-3 (Class B) DNV GL conducted interference Class B Additional text Bridge and deck area DNV GL noise radiation Class B Additional text Bridge and deck area Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV (Test Level 4) Discharge in air 8 kV (Test Level 3) Comments Criterion A Electromagnetic HF field Standards/regulations EN 61000-4-3 Electromagnetic HF field Frequency range 80 MHz ... 1 GHz Test field strength 20 V/m (Test Level 3) Frequency range 1 GHz ... 6 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) Standards/regulations EN 61000-4-4 Fast transients (burst) Input 2 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 4 - asymmetrical) Signal 2 kV (Test Level 4 - asymmetrical) Comments Criterion B Surge voltage load (surge) Standards/regulations EN 61000-4-5 Input 1 kV (Test Level 4 - symmetrical) 2 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 4 - symmetrical) Jan 8, 2024, 9:27 AM Page 7 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 2 kV (Test Level 4 - asymmetrical) Comments Criterion A Conducted interference Standards/regulations EN 61000-4-6 Conducted interference I/O/S asymmetrical Frequency range 0.15 MHz ... 80 MHz Comments Criterion A Voltage 10 V (Test Level 3) Power frequency magnetic field Standards/regulations EN 61000-4-8 Frequency 16.67 Hz 50 Hz 60 Hz Test field strength 100 A/m Additional text 60 s Comments Criterion A Frequency 50 Hz 60 Hz Frequency range 50 Hz ... 60 Hz Test field strength 1 kA/m Additional text 3s Frequency 0 Hz Test field strength 300 A/m Additional text DC, 60 s Voltage dips Standards/regulations EN 61000-4-29 Voltage 24 V DC Voltage dip 70 % Number of periods 0.5 / 1 / 25 periods Time 100 ms Additional text Test Level 2 Comments Criterion A Voltage dip 40 % Number of periods 5 / 10 / 50 periods Time 100 ms Additional text Test Level 2 Comments Criterion A Voltage dip 0% Number of periods 0.5 / 1 / 5 / 50 periods Time 50 ms Additional text Test Level 2 Jan 8, 2024, 9:27 AM Page 8 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Comments Criterion B Pulse-shape magnetic field Standards/regulations EN 61000-4-9 Test field strength 1000 A/m Comments Criterion A Asymmetrical conducted disturbance variables Standards/regulations EN 61000-4-16 Test level 1 15 Hz 150 Hz (Test Level 3) Voltage 10 V 1 V (Permanent) Test level 2 150 Hz 1.5 kHz (Test Level 3) Voltage 1V Test level 3 1.5 kHz 15 kHz (Test Level 3) Voltage 1 V 10 V Test level 4 15 kHz 150 kHz (Test Level 3) Voltage 10 V Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) Voltage 10 V (Permanent) Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) Voltage 100 V (1 s) Comments Criterion A Alternating component of direct voltage Standards/regulations EN 61000-4-17 Alternating component 10 % (UN) Frequency 50 Hz 100 Hz 150 Hz 300 Hz Comments Criterion A Attenuated oscillating wave Standards/regulations EN 61000-4-18 Input, output (test level 1) 1 MHz (Test Level 2 - symmetrical) Voltage 0.5 kV Input, output (test level 2) 1 MHz (Test Level 2 - asymmetrical) Voltage 1 kV Signals (test level 1) 1 MHz (Test Level 2 - symmetrical) Voltage 0.5 kV Signals (test level 2) 1 MHz (Test Level 2 - asymmetrical) Voltage 1 kV Comments Criterion A Attenuated oscillating magnetic field Standards/regulations EN 61000-4-10 Jan 8, 2024, 9:27 AM Page 9 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Test field strength 100 A/m Test level 1 100 kHz Test field strength 100 A/m Test level 2 1 MHz Comments Criterion A Criteria Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. Jan 8, 2024, 9:27 AM Page 10 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Drawings IIn [A] Diagram 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 0,00 0,25 2 1 1 = U : 12 V DC/U : 24 V DC In Out 2 = UIn: 24 V DC/UOut: 24 V DC 0,50 0,75 1,00 1,25 1,50 1,75 2,00 IOut [A] Eta [%] Diagram 100 90 80 70 2 60 50 40 30 20 10 0 0,00 0,25 0,50 1 1 = UIn: 12 V DC/UOut: 24 V DC 2 = UIn: 24 V DC/UOut: 24 V DC 0,75 1,00 1,25 1,50 1,75 2,00 IOut [A] Jan 8, 2024, 9:27 AM Page 11 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Dimensional drawing 3.1 2.1 2.2 SIG Output DC + − UOut Signal (SIG) POut > PThr Boost > 100% > 75% > 50% 106 QUINT POWER Ord.No.xxxxxxx 53 22,5 DC OK Input DC + − 1.1 1.2 Jan 8, 2024, 9:27 AM Page 12 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Schematic diagram Housing (+) L N (-) Input Signaling A A Output + Jan 8, 2024, 9:27 AM Page 13 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Block diagram + - 1.1 2.1 1.2 2.2 3.1 OVP + SIG SIG C Jan 8, 2024, 9:27 AM Page 14 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1066716  IECEE CB Scheme  IECEE CB Scheme  Approval ID: DK-97404-UL Approval ID: DE/PTZ/0122 cULus Listed Approval ID: FILE E 123528 DNV Approval ID: TAA00000BV  cULus Listed Approval ID: FILE E 199827 Jan 8, 2024, 9:27 AM Page 15 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Classifications ECLASS ECLASS-11.0 27040701 ECLASS-12.0 27040701 ECLASS-13.0 27040701 ETIM ETIM 9.0 EC002540 UNSPSC UNSPSC 21.0 39121000 Jan 8, 2024, 9:27 AM Page 16 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Environmental product compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Jan 8, 2024, 9:27 AM Page 17 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 Accessories SF-SL 0,4X2,0-60 - Screwdriver 1212546 https://www.phoenixcontact.com/us/products/1212546 Screwdriver, flat bladed, size: 0.4 x 2.0 x 60 mm, 2-component grip, with non-slip grip CBMC E4 24DC/1-10A NO - Electronic circuit breaker 2906032 https://www.phoenixcontact.com/us/products/2906032 Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails. CBMC E4 24DC/1-4A NO - Electronic circuit breaker 2906031 https://www.phoenixcontact.com/us/products/2906031 Multi-channel electronic circuit breaker for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails. Jan 8, 2024, 9:27 AM Page 18 (19) QUINT4-PS/12-24DC/24DC/1.3/PT - DC/DC converter 1066716 https://www.phoenixcontact.com/us/products/1066716 CBMC E4 24DC/1-4A NO-C - Electronic circuit breaker 2908713 https://www.phoenixcontact.com/us/products/2908713 Multi-channel electronic circuit breaker that can be preconfigured, for protecting four loads at 24 V DC in the event of overload and short circuit. With electronic locking of the set nominal currents. For installation on DIN rails. PLT-SEC-T3-24-FM-UT - Type 3 surge protection device 2907916 https://www.phoenixcontact.com/us/products/2907916 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 24 V AC/DC Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:27 AM Page 19 (19)
1066716 价格&库存

很抱歉,暂时无法提供与“1066716”相匹配的价格&库存,您可以联系我们找货

免费人工找货