PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user
documentation. Our general terms of use for downloads are valid.
Contact carrier, Range of articles: PRC 35, design: Release with tool or by hand (see accessories), housing material: PPE, color: black,
number of positions: 5, min. conductor cross section: 1.5 mm2, max. conductor cross section: 6 mm2, rated voltage: 690 V AC, rated
current: 35 A, Connection method: Screw connection, Contact connection type: Socket. Contact insert without connector housing.
Please order the appropriate connector housings according to the accessories list.
Your advantages
• Versatile interfaces with straight and angled connector housings
• Universal accommodation of existing connector heads with screw connection technology
• Modular system for optimized storage
• Locking mechanism can be unlocked manually or using a tool
• Ideal for indoor and outdoor use due to weatherproof materials
Commercial data
Item number
1070197
Packing unit
1 pc
Minimum order quantity
1 pc
Sales key
AB03
Product key
ABLCBA
GTIN
4055626748498
Weight per piece (including packing)
52.3 g
Weight per piece (excluding packing)
22.22 g
Customs tariff number
85366990
Country of origin
PL
Jan 8, 2024, 9:30 AM
Page 1 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Technical data
Notes
General
Contact insert without connector housing. Please order the
appropriate connector housings according to the accessories list.
General
For assembly notes, please refer to the packing slip
Safety note
Safety note
• WARNING: Commission properly functioning products only.
The products must be regularly inspected for damage.
Decommission defective products immediately. Replace
damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and
operate the product. They must observe the following safety
notes. The qualified personnel must be familiar with the basics of
electrical engineering. They must be able to recognize and
prevent danger. The relevant symbol on the packaging indicates
that only personnel familiar with electrical engineering are
allowed to install and operate the product.
WARNING: The connectors may not be plugged in or
disconnected under load. Ignoring the warning or improper use
may damage persons and/or property.
• Assembled products may not be manipulated or improperly
opened.
• Only use mating connectors that are specified in the technical
data of the standards listed (e.g. the ones listed in the product
accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector
housings must be grounded
• Ensure that the protective or functional ground has been
properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3
are applicable when combining several circuits in a cable and/or
connector
• Observe the corresponding technical data. You will find
information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• The installation notes/Design In documents online on the
download page at phoenixcontact.com/products must be
observed for this product.
• Use a protective cap to protect connectors that are not in use.
The suitable accessories are available online in the accessory
section of the product at phoenixcontact.com/products
• Operate the connector only when it is fully plugged in.
• Operate the connector only when it is fully plugged in and
interlocked.
Jan 8, 2024, 9:30 AM
Page 2 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
• Ensure that when laying the cable, the tensile load on the
connectors does not exceed the upper limit specified in the
standards.
• Observe the minimum bending radius of the cable. Lay the
cable without twisting it.
• The connector warms up in normal operation. Depending on the
ambient conditions, the surface of the connector can continue to
warm up. In this case, the user is responsible for posting
warnings (e.g. DIN EN ISO 13732-1:2008-12).
Product properties
Type
Release with tool or by hand (see accessories)
Product type
Contact insert
Product family
PRC 35
Number of positions
5
Connection profile
4+PE
Coding
AD
Insulation characteristics
Protection class
II
Degree of pollution
2
Electrical properties
Rated voltage (III/2)
690 V
Nominal voltage ATD
690 V AC (III/2) in accordance with IEC 61984, when mounted
600 V AC / DC (III/2)
500 V DC (III/2) in accordance with IEC 61535, when mounted
Rated surge voltage (III/2)
8 kV
Rated current
35 A (With 6 mm² conductor cross section in accordance with
IEC 61984)
28 A (with AWG 10, in accordance with UL 2237)
32 A (With 6 mm² conductor cross section in accordance with
IEC 61535)
Connection data
Connection method
Screw connection
Conductor cross section flexible
4 mm² ... 6 mm²
Conductor cross section rigid
1.5 mm² ... 6 mm²
Dimensions
Width
35.9 mm
Height
34.5 mm
Length
51.2 mm
Material specifications
Color
black
Color of the housing part
black
Jan 8, 2024, 9:30 AM
Page 3 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Material
EPDM
PPE
CuZn
Flammability rating according to UL 94
V0
Insulating material group
I / CTI 600
Contact material
Cu alloy
Contact surface material
silver-plated
Contact carrier material
PPE
O-ring material
EPDM
Housing material
PPE
Cable/line
Single wire, cross section
1.5 mm² 6 mm² 14 AWG 10 AWG
Stripping length of the individual wire
12 mm (Lay PE conductor 8 mm leading)
Halogen-free
yes
Mechanical properties
Mechanical data
Insertion/withdrawal cycles
2000 (Test specification: IEC 60512-13-2)
Insertion force
50 N ±10 N (Test specification: IEC 60512-13-2)
Environmental and real-life conditions
Ambient conditions
Degree of protection (when plugged in)
IP66 / IP68 (2m / 24h) / IP69K (when mounted)
Degree of protection
IP66 / IP68 (2m / 24h) / IP69K (when mounted)
IP66 / IP68 (2m / 24h) / IP69K
Ambient temperature (operation)
-40 °C ... 105 °C (dependent on the derating curve)
Ambient temperature (storage/transport)
-40 °C ... 70 °C
Ambient temperature (assembly)
-5 °C ... 85 °C
Mounting
Connection method
Screw connection
Jan 8, 2024, 9:30 AM
Page 4 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Drawings
Schematic diagram
PE
A
3
2
D
N
1
Connector pin assignment
Jan 8, 2024, 9:30 AM
Page 5 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1070197
cUL Recognized
UL Recognized
VDE Zeichengenehmigung
Approval ID: E468743-20200116
Approval ID: E468743-20200116
Approval ID: 40054231
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
690 V
35 A
-
-
Nominal voltage UN
Nominal current IN
Cross section AWG
Cross section mm2
500 V
32 A
-
-
VDE Zeichengenehmigung
Approval ID: 40054228
cULus Recognized
Jan 8, 2024, 9:30 AM
Page 6 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Classifications
ECLASS
ECLASS-11.0
27440109
ECLASS-12.0
27440109
ECLASS-13.0
27440109
ETIM
ETIM 9.0
EC003569
UNSPSC
UNSPSC 21.0
39121400
Jan 8, 2024, 9:30 AM
Page 7 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Environmental product compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Jan 8, 2024, 9:30 AM
Page 8 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Mandatory accessories
PRC FT25-0-HSG - Device connector front mounting
1065795
https://www.phoenixcontact.com/us/products/1065795
Device connector front mounting,
Range of articles: PRC 35, housing
material: PPE, color: black, rated
voltage: 690 V AC. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
PRC FC-45/90-HSG 8-21 - Connector housing
1065798
https://www.phoenixcontact.com/us/products/1065798
Connector housing, Range of articles:
PRC 35, housing material: PPE, color:
black, rated voltage: 690 V AC, min.
cable diameter: 8 mm, max. cable
diameter: 21 mm. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
Jan 8, 2024, 9:30 AM
Page 9 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
PRC FT25-45/90-HSG - Device connector front mounting
1065796
https://www.phoenixcontact.com/us/products/1065796
Device connector front mounting,
Range of articles: PRC 35, housing
material: PPE, color: black, rated
voltage: 690 V AC. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
Accessories
PRC FT25-0-HSG - Device connector front mounting
1065795
https://www.phoenixcontact.com/us/products/1065795
Device connector front mounting,
Range of articles: PRC 35, housing
material: PPE, color: black, rated
voltage: 690 V AC. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
PRC FT25-45/90-HSG - Device connector front mounting
1065796
https://www.phoenixcontact.com/us/products/1065796
Device connector front mounting,
Range of articles: PRC 35, housing
material: PPE, color: black, rated
voltage: 690 V AC. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
Jan 8, 2024, 9:30 AM
Page 10 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
PRC FC-45/90-HSG 8-21 - Connector housing
1065798
https://www.phoenixcontact.com/us/products/1065798
Connector housing, Range of articles:
PRC 35, housing material: PPE, color:
black, rated voltage: 690 V AC, min.
cable diameter: 8 mm, max. cable
diameter: 21 mm. Connector housing
without contact insert. Please order
the appropriate contact inserts
according to the accessories list
PRC COVER F - Protective cap
1409236
https://www.phoenixcontact.com/us/products/1409236
Protective cap, Range of articles:
PRC 35, housing material: PPE, color:
black, rated voltage: 1000. Suitable
for couplings (FS)
SZF 1-0,6X3,5 - Screwdriver
1204517
https://www.phoenixcontact.com/us/products/1204517
Actuation tool, for ST terminal blocks, also suitable for use as a bladed
screwdriver, size: 0.6 x 3.5 x 100 mm, 2-component grip, with non-slip grip
Jan 8, 2024, 9:30 AM
Page 11 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
SF-PH 1-80 S-VDE - Screwdriver
1212693
https://www.phoenixcontact.com/us/products/1212693
Screwdriver, crosshead PH (lasered), insulated, size: PH 1 x 80, 2-component
handle, with non-slip grip
PRC FC RELEASE LATCH BU - Color coding
1002293
https://www.phoenixcontact.com/us/products/1002293
Color coding, Range of articles: PRC
35, housing material: PA 6.6-FR. If
you are using the release latch, then
the PRC approvals in accordance with
IEC 61535 and 2PfG 1915 are not
required
PRC FC RELEASE LATCH GY - Color coding
1002292
https://www.phoenixcontact.com/us/products/1002292
Color coding, Range of articles: PRC
35, housing material: PA 6.6-FR. If
you are using the release latch, then
the PRC approvals in accordance with
IEC 61535 and 2PfG 1915 are not
required
Jan 8, 2024, 9:30 AM
Page 12 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
PRC FC RELEASE LATCH GN - Color coding
1002290
https://www.phoenixcontact.com/us/products/1002290
Color coding, Range of articles: PRC
35, housing material: PA 6.6-FR. If
you are using the release latch, then
the PRC approvals in accordance with
IEC 61535 and 2PfG 1915 are not
required
PRC FC RELEASE LATCH RD - Color coding
1125075
https://www.phoenixcontact.com/us/products/1125075
Color coding, Range of articles: PRC
35, housing material: PA 6.6-FR. If
you are using the release latch, then
the PRC approvals in accordance with
IEC 61535 and 2PfG 1915 are not
required
PRC FC RELEASE LATCH YE - Color coding
1125073
https://www.phoenixcontact.com/us/products/1125073
Color coding, Range of articles: PRC
35, housing material: PA 6.6-FR. If
you are using the release latch, then
the PRC approvals in accordance with
IEC 61535 and 2PfG 1915 are not
required
Jan 8, 2024, 9:30 AM
Page 13 (14)
PRC 5-HEAD-FS6-1 - Contact carrier
1070197
https://www.phoenixcontact.com/us/products/1070197
Phoenix Contact 2024 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Jan 8, 2024, 9:30 AM
Page 14 (14)