0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1075240

1075240

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    TRIO-PS-2G/1500DC/24DC/8

  • 数据手册
  • 价格&库存
1075240 数据手册
https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply with Push-in connection for DIN rail mounting, input: 1,500 V DC, output: 24 V DC / 8 A Key Commercial Data Packing unit 1 pc Custom tariff number 85044030 Country of origin China Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 88.5 mm Height 130 mm Depth 160 mm Ambient conditions Degree of protection IP20 Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Ambient temperature (operation) -25 °C ... 70 °C (>60°C derating: 1.2%/K) Ambient temperature (start-up type tested) -40 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 06/17/2020   Page 1 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Technical data Ambient conditions Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) Input data Nominal input voltage range 600 V DC ... 1500 V DC Input voltage range 510 V DC ... 1650 V DC Dielectric strength maximum ≤ 1800 V DC 1 s Current consumption typ. 0.35 A (600 V DC) typ. 0.145 A (1500 V DC) Recommended breaker for input protection 2 A (gPV) Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 8A Derating > 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series No Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) ≤ 30 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Residual ripple < 40 mVPP < 50 mVPP Output power 192 W Maximum power dissipation in no-load condition 1500000 h (25 °C) > 900000 h (40 °C) > 400000 h (60 °C) Insulation voltage input/output 4.2 kV DC (type test) 2.6 kV DC (routine test) Degree of protection IP20 Protection class I 06/17/2020   Page 2 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Technical data General Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 1 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 1 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 18 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 1 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 1 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 18 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards Standard - Electrical safety EN 62109-1:2011 Standard – Safety extra-low voltage IEC 62109-1:2011 (SELV) Standard - Safe isolation DIN VDE 0100-410 Conformance/approvals 06/17/2020   Page 3 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Technical data Conformance/approvals UL approvals UL 62109-1:2014 EMC data Electrostatic discharge EN 61000-4-2 Contact discharge 4 kV (Test Level 2) Discharge in air 8 kV (Test Level 3) Electromagnetic HF field EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 20 V/m (> Test intensity 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 3 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input 3 kV (> Test intensity 4 – symmetrical) 6 kV (> Test intensity 4 – asymmetrical) Output 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 3 - symmetrical) Comments Criterion B Conducted interference EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Environmental Product Compliance REACh SVHC Lead 7439-92-1 Drawings 06/17/2020   Page 4 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Connection diagram Block diagram 06/17/2020   Page 5 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Diagram 06/17/2020   Page 6 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Dimensional drawing 06/17/2020   Page 7 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Dimensional drawing Classifications eCl@ss eCl@ss 9.0 27210901 Approvals Approvals Approvals UL Recognized / cUL Recognized / IECEE CB Scheme / cULus Recognized Ex Approvals 06/17/2020   Page 8 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Approvals Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 476951 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 476951 IECEE CB Scheme    http://www.iecee.org/  US-33734-UL cULus Recognized       Accessories Accessories Device circuit breakers Electronic device circuit breaker - CBM E4 24DC/0.5-10A NO-R - 2905743 Multi-channel, electronic device circuit breaker with active current limitation for protecting four loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Electronic device circuit breaker - CBM E8 24DC/0.5-10A NO-R - 2905744 Multi-channel, electronic device circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails.     Potential distributor 06/17/2020   Page 9 / 10 https://www.phoenixcontact.com/us/products/1075240 Power supply unit - TRIO-PS-2G/1500DC/24DC/8 - 1075240 Accessories Potential distributors - VIP-2/SC/PDM-2/24 - 2315269 VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 70.4 mm     Potential distributors - VIP-3/PT/PDM-2/24 - 2903798 VARIOFACE module with push-in connection and two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 57.1 mm     PV arrester Type 2 surge arrester - VAL-MS 1500DC-PV/2+V - 1033708 Surge arrester for 2-pos. isolated 1500 V DC voltage systems, for DIN rail mounting, 3-pos. base element, three plug-in temperature-monitored protective elements, status message on each plug.     Lightning/surge arrester type 1/2 - VAL-MB-T1/T2 1500DC-PV/2+V - 2905641 Lightning/surge arrester for 2-pos. isolated 1500 V DC voltage systems, for DIN rail mounting, temperature-monitored protective elements, status message on the module.     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/17/2020   Page 10 / 10
1075240 价格&库存

很抱歉,暂时无法提供与“1075240”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1075240
    •  国内价格 香港价格
    • 1+3615.786671+448.53666
    • 10+3401.1920710+421.91630

    库存:11