0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1076188

1076188

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 72V 1008W

  • 数据手册
  • 价格&库存
1076188 数据手册
https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 72 V DC/14 A, dynamic boost, tool-free fast connection technology for rigid and flexible conductors with ferrule Product Description TRIO POWER power supplies with standard functionality The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads. Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626783918 Weight per Piece (excluding packing) 3,060.000 g Custom tariff number 85044030 Country of origin China Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 110 mm Height 130 mm Depth 160 mm Installation distance right/left 0 mm / 0 mm 04/22/2021   Page 1 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Technical data Dimensions Installation distance top/bottom 50 mm / 50 mm Ambient conditions Degree of protection IP20 Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) Input data Nominal input voltage range 3x 400 V AC ... 500 V AC Input voltage range 3x 400 V AC ... 500 V AC -20 % ....+15 % AC frequency range 50 Hz ... 60 Hz Frequency range (fN) 50 Hz ... 60 Hz ±5 Hz Discharge current to PE < 3.5 mA Current consumption 3x 1.9 A (400 V AC) 3x 1.7 A (500 V AC) Nominal power consumption 1335.1 VA Inrush current ≤ 30 A (typical) Mains buffering time > 10 ms (400 V AC) > 20 ms (480 V AC) Input fuse 6.3 A (internal (device protection)) Recommended breaker for input protection 10 A ... 16 A (Characteristics B, C, D, K) Power factor (cos phi) 0.77 Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 72 V DC ±1 % Setting range of the output voltage (USet) 70 V DC ... 85 V DC (> 72 V DC, constant capacity restricted) Nominal output current (IN) 14 A Dynamic Boost (IDyn.Boost) 21 A (5 s) Derating > 60 °C ... 70 °C (2.5%/K) Connection in parallel yes Connection in series yes 04/22/2021   Page 2 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Technical data Output data Feedback voltage resistance < 105 V DC Protection against overvoltage at the output (OVP) ≤ 105 V DC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Residual ripple ≤ 300 mVPP Output power 1008 W Typical response time 94.6 % (400 V AC) > 94.3 % (480 V AC) MTBF (IEC 61709, SN 29500) > 1730000 h (25 °C) > 1051000 h (40 °C) > 510000 h (60 °C) Insulation voltage input/output 3 kV AC (type test) 1.5 kV AC (routine test) Degree of protection IP20 Protection class I (in closed control cabinet) Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 4 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection 04/22/2021   Page 3 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Technical data Connection data, output Conductor cross section solid min. 0.75 mm² Conductor cross section solid max. 16 mm² Conductor cross section flexible min. 0.75 mm² Conductor cross section flexible max. 16 mm² Conductor cross section AWG min. 20 Conductor cross section AWG max. 4 Stripping length 18 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 0.75 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 1.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 18 Stripping length 8 mm Standards EMC requirements for noise immunity EN 61000-6-1 EN 61000-6-2 Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC 61010-2-201 Standard - Safe isolation DIN VDE 0100-410 Standard – Limitation of mains harmonic currents EN 61000-3-2 Conformance/approvals UL approvals UL/C-UL Listed UL 61010-1 EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Conducted noise emission EN 55016-2-1 EN 61000-6-4 (Class A) Noise emission EN 55016-2-3 EN 61000-6-4 (Class A) Harmonic currents EN 55016-2-3 EN 61000-3-2 (Class A) Flicker EN 61000-3-3 04/22/2021   Page 4 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Technical data EMC data EN 61000-3-3 Electrostatic discharge EN 61000-4-2 Contact discharge 6 kV (Test Level 3) Discharge in air 8 kV (Test Level 3) Electromagnetic HF field EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 6 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN 61000-4-4 Input 4 kV (Test Level 3 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion A Conducted interference EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Voltage dips EN 61000-4-11 Voltage 400 V AC Frequency 50 Hz Voltage dip 70 % Number of periods 25 periods Comments Criterion A Voltage dip 40 % Number of periods 10 periods Comments Criterion A 04/22/2021   Page 5 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Technical data EMC data Voltage dip 0% Number of periods 1 period Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Block diagram L1 L2 L3 Diagram Output DC 1.1 2.1 1.2 2.2 1.3 2.3 2.4 1.4 2.5 3.1 3.2 + POut [%] Input 3AC + 13 14 200 175 150 125 100 75 50 25 0 " ! = PN 100 % # 60 °C " = PDyn. 150 % # 60 °C 0 1000 2000 ! 3000 4000 5000 H [m] Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 11.0 27040701 eCl@ss 9.0 27040701 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed 04/22/2021   Page 6 / 7 https://www.phoenixcontact.com/us/products/1076188 Power supply unit - TRIO-PS-2G/3AC/72DC/14 - 1076188 Approvals Ex Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 cULus Listed       Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com 04/22/2021   Page 7 / 7
1076188 价格&库存

很抱歉,暂时无法提供与“1076188”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1076188
    •  国内价格
    • 1+3113.18299

    库存:3