Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W
Product description
UNO POWER power supplies with basic functionality
Thanks to their high power density, compact UNO POWER power supplies are the ideal solution for loads up to 240 W, particularly in compact
control boxes. The power supply units are available in various performance classes and overall widths. Their high degree of efficiency and low idling
losses ensure a high level of energy efficiency.
Your advantages
• Flexible mounting by simply snapping onto the DIN rail
• More space in the control cabinet with up to 20 % higher power density
• Maximum energy efficiency, thanks to over 90 % efficiency and extremely low idling losses under 0.3 W
• Outdoor installation, thanks to the wide temperature range from -25°C to +70°C
Commercial data
Item number
1088851
Packing unit
1 pc
Minimum order quantity
1 pc
Sales key
CM14
Product key
CMPU1Y
GTIN
4055626890661
Weight per piece (including packing)
381.4 g
Weight per piece (excluding packing)
340 g
Customs tariff number
85044095
Country of origin
DE
Jan 8, 2024, 9:33 AM
Page 1 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Technical data
Input data
AC operation
Nominal input voltage range
100 V AC ... 240 V AC
Input voltage range
85 V AC ... 264 V AC
Input voltage range AC
85 V AC ... 264 V AC
Voltage type of supply voltage
AC
Inrush current
< 40 A (typical)
2
Inrush current integral (I t)
< 1.5 A2s
Frequency range (fN)
50 Hz ... 60 Hz ±10 %
Mains buffering time
> 20 ms (120 V AC)
> 100 ms (230 V AC)
Current consumption
2.1 A (100 V AC)
0.95 A (240 V AC)
Nominal power consumption
242.6 VA
Protective circuit
Transient surge protection; Varistor
Power factor (cos phi)
0.47
Typical response time
738000 h (40 °C)
Insulation characteristics
Protection class
II (in closed control cabinet)
Degree of pollution
2
Jan 8, 2024, 9:33 AM
Page 3 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Dimensions
Width
55 mm
Height
90 mm
Depth
84 mm
Installation dimensions
Installation distance right/left
0 mm / 0 mm
Installation distance top/bottom
30 mm / 30 mm
Mounting
Mounting type
DIN rail mounting
Assembly instructions
alignable: 0 mm horizontally, 30 mm vertically
Mounting position
horizontal DIN rail NS 35, EN 60715
With protective coating
No
Material specifications
Flammability rating according to UL 94 (housing / terminal
blocks)
V0
Housing material
Plastic
Type of housing
Polycarbonate
Foot latch material
POM (Polyoxymethylene)
Housing material
Polycarbonate
Environmental and real-life conditions
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Ambient temperature (start-up type tested)
-40 °C
Climatic class
3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Shock
18 ms, 30g, in each space direction (according to IEC 60068-227)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulations
Budgetary standard
IEC 60335-1
Standard – Electronic equipment for use in electrical power
installations and their assembly into electrical power installations
EN 50178/VDE 0160 (PELV)
Standard – Limitation of mains harmonic currents
EN 61000-3-2
Standard - Electrical safety
IEC 62368-1 (SELV)
Standard – Safety extra-low voltage
IEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard - Safe isolation
DIN VDE 0100-410
Jan 8, 2024, 9:33 AM
Page 4 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Standard - Safety of transformers
EN 61558-2-16
Approval - requirement of the semiconductor industry with regard
to mains voltage dips
EN 61000-4-11
Approvals
CSA
CAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01
CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D
T4 (Hazardous Location)
UL approvals
UL/C-UL listed UL 508
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A,
B, C, D T4 (Hazardous Location)
UL/C-UL Recognized UL 60950-1
Conformity/Approvals
SIL in accordance with IEC 61508
0
EMC data
Low Voltage Directive
Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission
EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity
EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations
EN 61000-4-2
Electrostatic discharge
Contact discharge
6 kV (Test Level 3)
Discharge in air
8 kV (Test Level 3)
Comments
Criterion B
Electromagnetic HF field
Standards/regulations
EN 61000-4-3
Electromagnetic HF field
Frequency range
80 MHz ... 1 GHz
Test field strength
10 V/m (Test Level 3)
Frequency range
1 GHz ... 6 GHz
Test field strength
10 V/m (Test Level 3)
Comments
Criterion A
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Fast transients (burst)
Input
4 kV (Test Level 4 - asymmetrical)
Jan 8, 2024, 9:33 AM
Page 5 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Output
2 kV (Test Level 3 - asymmetrical)
Comments
Criterion A
Surge voltage load (surge)
Standards/regulations
EN 61000-4-5
Input
2 kV (Test Level 3 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output
1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 1 - asymmetrical)
Comments
Criterion B
Conducted interference
Standards/regulations
EN 61000-4-6
Conducted interference
Input/Output
asymmetrical
Frequency range
0.15 MHz ... 80 MHz
Comments
Criterion A
Voltage
10 V (Test Level 3)
Voltage dips
Standards/regulations
EN 61000-4-11
Emitted interference
Standards/regulations
EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) class B used in industry and residential
area / EMC 1
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) class B used in industry and residential
area / EMC 1
Criteria
Criterion A
Normal operating behavior within the specified limits.
Criterion B
Temporary impairment to operational behavior that is corrected
by the device itself.
Jan 8, 2024, 9:33 AM
Page 6 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1088851
IECEE CB Scheme
Approval ID: SI-7104
EAC
EAC
Approval ID: RU S-DE.BL08.W.00764
Approval ID: RU S-DE.BL08.W.00764
cULus Listed
cULus Listed
Approval ID: FILE E 214596
Approval ID: FILE E 214596
EAC
Approval ID: RU S-DE.BL08.W.00764
IECEE CB Scheme
Approval ID: SI-7104
EAC
Approval ID: RU S-DE.BL08.W.00764
cULus Listed
cULus Listed
Approval ID: FILE E 123528
Approval ID: FILE E 123528
EAC
Approval ID: RU S-DE.BL08.W.00764
Jan 8, 2024, 9:33 AM
Page 7 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
EAC
Approval ID: RU S-DE.BL08.W.00764
cULus Listed
cULus Listed
Approval ID: FILE E 199827
Approval ID: FILE E 199827
Jan 8, 2024, 9:33 AM
Page 8 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Classifications
ECLASS
ECLASS-11.0
27040701
ECLASS-13.0
27040701
ECLASS-12.0
27040701
ETIM
ETIM 9.0
EC002540
UNSPSC
UNSPSC 21.0
39121000
Jan 8, 2024, 9:33 AM
Page 9 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Environmental product compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 25;
For information on hazardous substances, refer to the
manufacturer’s declaration available under “Downloads”
Jan 8, 2024, 9:33 AM
Page 10 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
Accessories
UNO-DIODE/5-24DC/2X10/1X20 - Redundancy module
2905489
https://www.phoenixcontact.com/us/products/2905489
Redundancy module, 5 V - 24 V DC, 2
x 10 A, 1 x 20 A.
CBMC E4 24DC/1-4A NO - Electronic circuit breaker
2906031
https://www.phoenixcontact.com/us/products/2906031
Multi-channel electronic circuit
breaker for protecting four loads at 24
V DC in the event of overload and
short circuit. With electronic locking of
the set nominal currents. For
installation on DIN rails.
CBMC E4 24DC/1-10A NO - Electronic circuit breaker
2906032
https://www.phoenixcontact.com/us/products/2906032
Multi-channel electronic circuit
breaker for protecting four loads at 24
V DC in the event of overload and
short circuit. With electronic locking of
the set nominal currents. For
installation on DIN rails.
Jan 8, 2024, 9:33 AM
Page 11 (12)
UNO-PS/1AC/24DC/100W/H - Power supply unit
1088851
https://www.phoenixcontact.com/us/products/1088851
PLT-SEC-T3-230-FM-UT - Type 3 surge protection device
2907919
https://www.phoenixcontact.com/us/products/2907919
Type 2/3 surge protection, consisting
of protective plug and base element
with screw connection. For singlephase power supply network with
integrated status indicator and remote
signaling. Nominal voltage:
230 V AC/DC
PLT-SEC-T3-24-FM-UT - Type 3 surge protection device
2907916
https://www.phoenixcontact.com/us/products/2907916
Type 3 surge protection, consisting of
protective plug and base element,
with integrated status indicator and
remote signaling for single-phase
power supply networks. Nominal
voltage: 24 V AC/DC
Phoenix Contact 2024 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Jan 8, 2024, 9:33 AM
Page 12 (12)