0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1088856

1088856

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    网络 交换机 - 托管型 16 个端口 IP20

  • 数据手册
  • 价格&库存
1088856 数据手册
https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Managed Switch 2000, 12 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, 2 Combo ports 10/100/1000 Mbps, degree of protection: IP20, PROFINET Conformance-Class B Your advantages  Suitable for PROFINET and EtherNet/IP™ networks  Easy and fast startup and commissioning with the FL NETWORK MANAGER software  Configuration memory  RSTP  DHCP client, DHCP server (pool-based and port-based), DHCP option 82  VLANs  MRP (client and manager)  Web-based management, SNMP  -40°C ... +70°C ambient temperature Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626889689 Weight per Piece (excluding packing) 1,300.000 g Custom tariff number 85176200 Country of origin Germany Technical data Note 10/14/2021   Page 1 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 214 mm Height 110 mm Depth 69 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 70 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing) Air pressure (operation) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) Degree of pollution 2 Interfaces Interface Ethernet (RJ45) No. of ports 12 (RJ45 ports) Note on the connection method Auto negotiation and autocrossing Transmission physics Copper Transmission speed 10/100/1000 Mbps Transmission length 100 m (per segment) Signal LEDs Data receive, link status Interface SFP module No. of ports 2 (SFP ports) Transmission physics Depending on the SFP module Transmission speed 100/1000 Mbps (full duplex) Transmission length up to 80 km (depending on the SFP module used) Signal LEDs Data receive, link status Interface Ethernet (combo) No. of ports 2 (Combo ports) Number of interfaces 2 Connection method SFP or RJ45 ports Note on the connection method Auto negotiation and autocrossing Transmission physics Depending on the SFP module Transmission speed 10/100/1000 Mbps (full duplex) 10/14/2021   Page 2 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Technical data Interfaces Transmission length up to 80 km (Depending on the fiber/SFP module used) Signal LEDs Data receive, link status Function Basic functions Store-and-forward switch, complies with IEEE 802.3 Configuration memory max. 8 GByte (SD card) Management Web-based management (HTTP/HTTPS) Role-based user management SNMPv1/v2/v3 Command-line interface (Telnet, SSH) Diagnostic functions RMON History LLDP (Link Layer Discovery Protocol) SNMP-Traps N:1-Portmirroring ACD (Address Conflict Detection) SysLog CRC-Surveillance Filter functions Quality of Service (8 priority classes) Class of Service DiffServ/DSCP Port-Priorisierung VLAN (up to 32 VLANs) IGMP Snooping/Querier (v1/v2) Auto-Query-Port Extended Multicast Filtering Redundancy MRP (Media Redundancy Protocol) RSTP (Rapid Spanning Tree Protocol) FRD (Fast Ring Detection) Large Tree Support LACP (Link Aggregation Control Protocol) Additional functions Jumbo frames (max. 9,600 bytes) Transmission of MMS and GOOSE (IEC 61850-8-1) Transmission of Modbus TCP MAC address table 8k Latency ≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size) IP parameterization DHCP-Client DHCP Option 82 (Relay Agent) 10/14/2021   Page 3 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Technical data Function DHCP server (pool-based, port-based) BootP DCP (Discovery and Configuration Protocol) PROFINET device function PROFINET device Fast Startup PROFINET conformance class Conformance-Class B Time synchronization SNTP (Simple Network Time Protocol) Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) Signal contact control voltage typ. 24 V DC Security functions Port security MAC-based, RADIUS (IEEE 802.1X) Network expansion parameters Cascading depth Network, linear, and star structure: any Maximum conductor length (twisted pair) 100 m Supply voltage Supply voltage 24 V DC (redundant) Residual ripple 3.6 VPP (within the permitted voltage range) Supply voltage range 19.2 V DC ... 32 V DC Typical current consumption 490 mA (at US = 24 V DC and 25 °C ambient temperature) Max. current consumption 820 mA (US = min, Tamb = max) General Mounting type DIN rail Type AX Block design Net weight 1035 g Housing material Stainless steel 1.4301 Material base plate Die-cast aluminum, corrosion-resistant Note Support by phone or on-site (fee is charged) Latency ≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size) MTTF 238.46 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) 137.07 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) 21.04 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) Connection data 10/14/2021   Page 4 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Technical data Connection data Connection method Push-in spring connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 10 mm Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion A Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A Type of test Free fall in accordance with EN 61131-2 Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6 Free from substances that could impair the application of coating Yes Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz Shock (operation) 30g (EN 60068-2-27) UL, USA UL 61010-1, Ed. 3 UL, Canada CSA C22.2 NO. 61010-1-12, Ed. 3 Noxious gas test ISA S71.04.2013 G3 Harsh Group A Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 10/14/2021   Page 5 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Connection diagram XG1 XD1 US1 GND US2 GND 2 1 24 V DC + 3 4 + 1 F1 F2 2 OUT 10/14/2021   Page 6 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Connection diagram XG1 XD1 US1 GND US2 GND 2 1 24 V DC 3 4 1 F1 F2 2 + OUT Classifications eCl@ss eCl@ss 10.0.1 19170401 eCl@ss 11.0 19170401 eCl@ss 9.0 19170106 ETIM ETIM 7.0 EC000734 UNSPSC UNSPSC 18.0 43222612 UNSPSC 19.0 43222612 UNSPSC 20.0 43222612 UNSPSC 21.0 43222612 Approvals Approvals 10/14/2021   Page 7 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Approvals Approvals BSH / UL Listed / cUL Listed / BV / ABS / LR / DNV GL / RINA / cULus Listed Ex Approvals Approval details BSH     1045 UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 BV    http://www.veristar.com/portal/veristarinfo/generalinfo/ approved/approvedProducts/equipmentAndMaterials  48146/A1 BV  http://www.eagle.org/eagleExternalPortalWEB/  21-2066186-PDA ABS  LR    http://www.lr.org/en  LR2160176TA DNV GL    https://approvalfinder.dnvgl.com/  TAA00000YV RINA    http://www.rina.org/en  ELE162721XG 10/14/2021   Page 8 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Approvals  cULus Listed      Accessories Accessories Data cable preassembled Patch cable - NBC-R4AC-R4AC-IE8A/.../... - 1411854 Patch cable, degree of protection: IP20, number of positions: 8, 10 Gbps, CAT6A, cable outlet: straight, Ethernet     Patch cable - NBC-R4AC/10G-R4AC/10G-94F/2,0 - 1408360 Patch cable, CAT6A, 4-pair, shielded, connection not crossed (line), assembled at both ends with RJ45/IP20 connectors, outer sheath material: PUR, length: 2.0 m     Patch cable - NBC-R4AC/10G-R4AC/10G-94F/3,0 - 1408365 Patch cable, CAT6A, 4-pair, shielded, connection not crossed (line), assembled at both ends with RJ45/IP20 connectors, outer sheath material: PUR, length: 3.0 m     Patch cable - NBC-R4AC/1,0-93B/R4AC - 1408968 Patch cable, degree of protection: IP20, cable length: 1 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6, PROFINET     10/14/2021   Page 9 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Patch cable - NBC-R4AC/2,0-93B/R4AC - 1408969 Patch cable, degree of protection: IP20, cable length: 2 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6, PROFINET     Patch cable - NBC-R4AC/5,0-93B/R4AC - 1408970 Patch cable, degree of protection: IP20, cable length: 5 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6, PROFINET     FO patch cable - FOC-LC:PA-SC:PA-OM2:D01/1 - 1115607 Multi-mode OM2 duplex jumper, LC-SC, UPC polishing, length 1 m     FO patch cable - FOC-LC:PA-SC:PA-OM2:D01/2 - 1115605 Multi-mode OM2 duplex jumper, LC-SC, UPC polishing, length 2 m     FO patch cable - FOC-LC:PA-LC:PA-OM2:D01/1 - 1115633 Multi-mode OM2 duplex jumper, LC-LC, UPC polishing, length 1 m     10/14/2021   Page 10 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories FO patch cable - FOC-LC:PA-LC:PA-OM2:D01/2 - 1115634 Multi-mode OM2 duplex jumper, LC-LC, UPC polishing, length 2 m     Fiber optic cable - FOC-LC:PA-ST:PA-OM2:D01/1 - 1115588 Multi-mode OM2 duplex jumper, LC-ST, UPC polishing, length 1 m     Fiber optic cable - FOC-LC:PA-ST:PA-OM2:D01/2 - 1115587 Multi-mode OM2 duplex jumper, LC-ST, UPC polishing, length 2 m     FO patch cable - FOC-LC:PA-SC:PA-OM4:D01/1 - 1115601 Multi-mode OM4 duplex jumper, LC-SC, UPC polishing, length 1 m     FO patch cable - FOC-LC:PA-SC:PA-OM4:D01/2 - 1115600 Multi-mode OM4 duplex jumper, LC-SC, UPC polishing, length 2 m     10/14/2021   Page 11 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories FO patch cable - FOC-LC:PA-LC:PA-OM4:D01/1 - 1115625 Multi-mode OM4 duplex jumper, LC-LC, UPC polishing, length 1 m     FO patch cable - FOC-LC:PA-LC:PA-OM4:D01/2 - 1115624 Multi-mode OM4 duplex jumper, LC-LC, UPC polishing, length 2 m     FO patch cable - FOC-LC:PA-LC:PA-OS2:D01/1 - 1115636 Single-mode OS2 duplex jumper, LC-LC, UPC polishing, length 1 m       FO patch cable - FOC-LC:PA-LC:PA-OS2:D01/2 - 1115629 Single-mode OS2 duplex jumper, LC-LC, UPC polishing, length 2 m       FO patch cable - FOC-LC:PA-ST:PA-OS2:D01/1 - 1115596 Single-mode OS2 duplex jumper, LC-ST, UPC polishing, length 1 m     10/14/2021   Page 12 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories FO patch cable - FOC-LC:PA-ST:PA-OS2:D01/2 - 1115595 Single-mode OS2 duplex jumper, LC-ST, UPC polishing, length 2 m     FO patch cable - FOC-LC:PA-SC:PA-OS2:D01/1 - 1115618 Single-mode OS2 duplex jumper, LC-SC, UPC polishing, length 1 m     FO patch cable - FOC-LC:PA-SC:PA-OS2:D01/2 - 1115617 Single-mode OS2 duplex jumper, LC-SC, UPC polishing, length 2 m     Drivers and interfaces Software - FL SNMP OPC SERVER V3 - 2701139 SNMP-OPC server, German and English, for monitoring and configuration of SNMP-capable equipment in HMI and SCADA systems     End block End clamp - E/NS 35 N - 0800886 End clamp, width: 9.5 mm, color: gray     10/14/2021   Page 13 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Mounting rail adapter DIN rail adapter - FL DIN RA - 2891053 The FL DIN RA is installed in a standard, 19-inch rack (EIA-310-D, IEC 60297-3-100) to allow DIN rail mounted equipment to be rack mounted.     Network management software Software - FL NETWORK MANAGER BASIC - 2702889 FL Network Manager, SNMP-based configuration and firmware update software, for easy startup of Managed Switches     Parameterization memory Memory - SD FLASH 512MB - 2988146 Program and configuration memory, plug-in, 512 Mbyte.     Program / configuration memory - SD FLASH 2GB - 2988162 Program and configuration memory, for extending the internal flash memory, pluggable, 2 GB.     Patch cable 10/14/2021   Page 14 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Patch cable - FL CAT5 PATCH 0,5 - 2832263 Patch cable, CAT5, assembled, 0.5 m     Patch cable - FL CAT5 PATCH 1,0 - 2832276 Patch cable, CAT5, assembled, 1 m     Patch cable - FL CAT5 PATCH 2,0 - 2832289 Patch cable, CAT5, assembled, 2 m     PCB plug PCB connector - FKCN 2,5/ 2-ST GY7035 BD:1-2 - 1082048 PCB connector, color: green, contact surface: Tin, Number of positions per row: 2, product range: FKCN 2,5/..-ST, pitch: 5 mm, type of packaging: packed in cardboard     PCB connector - FKCN 2,5/ 4-ST GY7035 BD:1-4 - 1082059 PCB connector, color: light gray, contact surface: Tin, Number of positions per row: 4, product range: FKCN 2,5/..-ST, pitch: 5 mm, type of packaging: packed in cardboard     Protective cap 10/14/2021   Page 15 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Dust protection - FL RJ45 PROTECT CAP - 2832991 Dust protection caps for RJ45 socket     SFP module Media module - FL SFP FX - 2891081 The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100  Mbps with a wavelength of 1310 nm (long).     Media module - FL SFP FX SM - 2891082 The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100  Mbps with a wavelength of 1310 nm (long).     Media module - FL SFP SX - 2891754 Gigabit SFP module for transmission up to 1 km with a wavelength of 850 nm.     Media module - FL SFP SX2 - 2702397 Gigabit SFP module for transmission up to 2 km with a wavelength of 1310 nm.     10/14/2021   Page 16 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Media module - FL SFP LX10-B - 1025401 Gigabit SFP module for transmission up to 10 km with a wavelength of 1310 nm.     Media module - FL SFP LX - 2891767 Gigabit SFP module for transmission up to 30 km with a wavelength of 1310 nm.     Media module - FL SFP LX40 - 1113081 Gigabit SFP module for transmission up to 40 km with a wavelength of 1310 nm     Media module - FL SFP LH - 2989912 Gigabit SFP module for transmission up to 80 km with a wavelength of 1,550 nm.     Media module - FL SFP WDM10-SET - 2702442 Gigabit SFP WDM set for transmission up to a maximum of 10 km on a single fiber with a wavelength of 1310/1550 nm.     10/14/2021   Page 17 / 18 https://www.phoenixcontact.com/us/products/1088856 Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856 Accessories Media module - FL SFP FE WDM20-SET - 2702439 Fast Ethernet SFP WDM set for transmission up to a maximum of 20 km on a single fiber with a wavelength of 1310/1550 nm.     Media module - FL SFP GT - 2989420 Gigabit SFP module for transmission up to 100 m.     Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com 10/14/2021   Page 18 / 18
1088856 价格&库存

很抱歉,暂时无法提供与“1088856”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1088856
  •  国内价格 香港价格
  • 1+17256.653981+2140.67991

库存:2