Managed Switch 2000, 12 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, 2 Combo ports
10/100/1000 Mbps, degree of protection: IP20, PROFINET Conformance-Class B
Your advantages
Suitable for PROFINET and EtherNet/IP™ networks
Easy and fast startup and commissioning with the FL NETWORK MANAGER software
Configuration memory
RSTP
DHCP client, DHCP server (pool-based and port-based), DHCP option 82
VLANs
MRP (client and manager)
Web-based management, SNMP
-40°C ... +70°C ambient temperature
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4055626889689
Weight per Piece (excluding packing)
1,300.000 g
Custom tariff number
85176200
Country of origin
Germany
Technical data
Note
10/14/2021 Page 1 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
214 mm
Height
110 mm
Depth
69 mm
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)
10 % ... 95 % (non-condensing)
Air pressure (operation)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Degree of pollution
2
Interfaces
Interface
Ethernet (RJ45)
No. of ports
12 (RJ45 ports)
Note on the connection method
Auto negotiation and autocrossing
Transmission physics
Copper
Transmission speed
10/100/1000 Mbps
Transmission length
100 m (per segment)
Signal LEDs
Data receive, link status
Interface
SFP module
No. of ports
2 (SFP ports)
Transmission physics
Depending on the SFP module
Transmission speed
100/1000 Mbps (full duplex)
Transmission length
up to 80 km (depending on the SFP module used)
Signal LEDs
Data receive, link status
Interface
Ethernet (combo)
No. of ports
2 (Combo ports)
Number of interfaces
2
Connection method
SFP or RJ45 ports
Note on the connection method
Auto negotiation and autocrossing
Transmission physics
Depending on the SFP module
Transmission speed
10/100/1000 Mbps (full duplex)
10/14/2021 Page 2 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Technical data
Interfaces
Transmission length
up to 80 km (Depending on the fiber/SFP module used)
Signal LEDs
Data receive, link status
Function
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Configuration memory
max. 8 GByte (SD card)
Management
Web-based management (HTTP/HTTPS)
Role-based user management
SNMPv1/v2/v3
Command-line interface (Telnet, SSH)
Diagnostic functions
RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Filter functions
Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
Redundancy
MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
Additional functions
Jumbo frames (max. 9,600 bytes)
Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus TCP
MAC address table
8k
Latency
≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the
frame size)
IP parameterization
DHCP-Client
DHCP Option 82 (Relay Agent)
10/14/2021 Page 3 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Technical data
Function
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
PROFINET device function
PROFINET device
Fast Startup
PROFINET conformance class
Conformance-Class B
Time synchronization
SNTP (Simple Network Time Protocol)
Status and diagnostic indicators
LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet
port (Link/Activity and Speed)
Signal contact control voltage
typ. 24 V DC
Security functions
Port security
MAC-based, RADIUS (IEEE 802.1X)
Network expansion parameters
Cascading depth
Network, linear, and star structure: any
Maximum conductor length (twisted pair)
100 m
Supply voltage
Supply voltage
24 V DC (redundant)
Residual ripple
3.6 VPP (within the permitted voltage range)
Supply voltage range
19.2 V DC ... 32 V DC
Typical current consumption
490 mA (at US = 24 V DC and 25 °C ambient temperature)
Max. current consumption
820 mA (US = min, Tamb = max)
General
Mounting type
DIN rail
Type AX
Block design
Net weight
1035 g
Housing material
Stainless steel 1.4301
Material base plate
Die-cast aluminum, corrosion-resistant
Note
Support by phone or on-site (fee is charged)
Latency
≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the
frame size)
MTTF
238.46 Years (SN 29500 standard, temperature 25°C, operating
cycle 21%)
137.07 Years (SN 29500 standard, temperature 40°C, operating
cycle 34.25%)
21.04 Years (SN 29500 standard, temperature 70°C, operating
cycle 100%)
Connection data
10/14/2021 Page 4 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Technical data
Connection data
Connection method
Push-in spring connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
16
Stripping length
10 mm
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Interference emission
EN 61000-6-2 EN 61000-6-4 (interference) Class A
Conducted noise emission
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Immunity to surge
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
Immunity to burst
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Immunity to EF
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
Immunity to ESD
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
Immunity to conducted interference
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
Type of test
Free fall in accordance with EN 61131-2
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2
Vibration (storage/transport)
5g, 150 Hz, in acc. with IEC 60068-2-6
Free from substances that could impair the application of coating
Yes
Vibration (operation)
in acc. with IEC 60068-2-6: 5g, 150 Hz
Shock (operation)
30g (EN 60068-2-27)
UL, USA
UL 61010-1, Ed. 3
UL, Canada
CSA C22.2 NO. 61010-1-12, Ed. 3
Noxious gas test
ISA S71.04.2013 G3 Harsh Group A
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
10/14/2021 Page 5 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Connection diagram
XG1
XD1
US1 GND US2 GND
2
1
24 V DC
+
3
4
+
1
F1
F2
2
OUT
10/14/2021 Page 6 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Connection diagram
XG1
XD1
US1 GND US2 GND
2
1
24 V DC
3
4
1
F1
F2
2
+
OUT
Classifications
eCl@ss
eCl@ss 10.0.1
19170401
eCl@ss 11.0
19170401
eCl@ss 9.0
19170106
ETIM
ETIM 7.0
EC000734
UNSPSC
UNSPSC 18.0
43222612
UNSPSC 19.0
43222612
UNSPSC 20.0
43222612
UNSPSC 21.0
43222612
Approvals
Approvals
10/14/2021 Page 7 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Approvals
Approvals
BSH / UL Listed / cUL Listed / BV / ABS / LR / DNV GL / RINA / cULus Listed
Ex Approvals
Approval details
BSH
1045
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
BV
http://www.veristar.com/portal/veristarinfo/generalinfo/
approved/approvedProducts/equipmentAndMaterials
48146/A1 BV
http://www.eagle.org/eagleExternalPortalWEB/
21-2066186-PDA
ABS
LR
http://www.lr.org/en
LR2160176TA
DNV GL
https://approvalfinder.dnvgl.com/
TAA00000YV
RINA
http://www.rina.org/en
ELE162721XG
10/14/2021 Page 8 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Approvals
cULus Listed
Accessories
Accessories
Data cable preassembled
Patch cable - NBC-R4AC-R4AC-IE8A/.../... - 1411854
Patch cable, degree of protection: IP20, number of positions: 8, 10 Gbps, CAT6A, cable outlet: straight, Ethernet
Patch cable - NBC-R4AC/10G-R4AC/10G-94F/2,0 - 1408360
Patch cable, CAT6A, 4-pair, shielded, connection not crossed (line), assembled at both ends with RJ45/IP20 connectors,
outer sheath material: PUR, length: 2.0 m
Patch cable - NBC-R4AC/10G-R4AC/10G-94F/3,0 - 1408365
Patch cable, CAT6A, 4-pair, shielded, connection not crossed (line), assembled at both ends with RJ45/IP20 connectors,
outer sheath material: PUR, length: 3.0 m
Patch cable - NBC-R4AC/1,0-93B/R4AC - 1408968
Patch cable, degree of protection: IP20, cable length: 1 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6,
PROFINET
10/14/2021 Page 9 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Patch cable - NBC-R4AC/2,0-93B/R4AC - 1408969
Patch cable, degree of protection: IP20, cable length: 2 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6,
PROFINET
Patch cable - NBC-R4AC/5,0-93B/R4AC - 1408970
Patch cable, degree of protection: IP20, cable length: 5 m, number of positions: 4, 100 Mbps, CAT5, material: PA 6.6,
PROFINET
FO patch cable - FOC-LC:PA-SC:PA-OM2:D01/1 - 1115607
Multi-mode OM2 duplex jumper, LC-SC, UPC polishing, length 1 m
FO patch cable - FOC-LC:PA-SC:PA-OM2:D01/2 - 1115605
Multi-mode OM2 duplex jumper, LC-SC, UPC polishing, length 2 m
FO patch cable - FOC-LC:PA-LC:PA-OM2:D01/1 - 1115633
Multi-mode OM2 duplex jumper, LC-LC, UPC polishing, length 1 m
10/14/2021 Page 10 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
FO patch cable - FOC-LC:PA-LC:PA-OM2:D01/2 - 1115634
Multi-mode OM2 duplex jumper, LC-LC, UPC polishing, length 2 m
Fiber optic cable - FOC-LC:PA-ST:PA-OM2:D01/1 - 1115588
Multi-mode OM2 duplex jumper, LC-ST, UPC polishing, length 1 m
Fiber optic cable - FOC-LC:PA-ST:PA-OM2:D01/2 - 1115587
Multi-mode OM2 duplex jumper, LC-ST, UPC polishing, length 2 m
FO patch cable - FOC-LC:PA-SC:PA-OM4:D01/1 - 1115601
Multi-mode OM4 duplex jumper, LC-SC, UPC polishing, length 1 m
FO patch cable - FOC-LC:PA-SC:PA-OM4:D01/2 - 1115600
Multi-mode OM4 duplex jumper, LC-SC, UPC polishing, length 2 m
10/14/2021 Page 11 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
FO patch cable - FOC-LC:PA-LC:PA-OM4:D01/1 - 1115625
Multi-mode OM4 duplex jumper, LC-LC, UPC polishing, length 1 m
FO patch cable - FOC-LC:PA-LC:PA-OM4:D01/2 - 1115624
Multi-mode OM4 duplex jumper, LC-LC, UPC polishing, length 2 m
FO patch cable - FOC-LC:PA-LC:PA-OS2:D01/1 - 1115636
Single-mode OS2 duplex jumper, LC-LC, UPC polishing, length 1 m
FO patch cable - FOC-LC:PA-LC:PA-OS2:D01/2 - 1115629
Single-mode OS2 duplex jumper, LC-LC, UPC polishing, length 2 m
FO patch cable - FOC-LC:PA-ST:PA-OS2:D01/1 - 1115596
Single-mode OS2 duplex jumper, LC-ST, UPC polishing, length 1 m
10/14/2021 Page 12 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
FO patch cable - FOC-LC:PA-ST:PA-OS2:D01/2 - 1115595
Single-mode OS2 duplex jumper, LC-ST, UPC polishing, length 2 m
FO patch cable - FOC-LC:PA-SC:PA-OS2:D01/1 - 1115618
Single-mode OS2 duplex jumper, LC-SC, UPC polishing, length 1 m
FO patch cable - FOC-LC:PA-SC:PA-OS2:D01/2 - 1115617
Single-mode OS2 duplex jumper, LC-SC, UPC polishing, length 2 m
Drivers and interfaces
Software - FL SNMP OPC SERVER V3 - 2701139
SNMP-OPC server, German and English, for monitoring and configuration of SNMP-capable equipment in HMI and
SCADA systems
End block
End clamp - E/NS 35 N - 0800886
End clamp, width: 9.5 mm, color: gray
10/14/2021 Page 13 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Mounting rail adapter
DIN rail adapter - FL DIN RA - 2891053
The FL DIN RA is installed in a standard, 19-inch rack (EIA-310-D, IEC 60297-3-100) to allow DIN rail mounted
equipment to be rack mounted.
Network management software
Software - FL NETWORK MANAGER BASIC - 2702889
FL Network Manager, SNMP-based configuration and firmware update software, for easy startup of Managed Switches
Parameterization memory
Memory - SD FLASH 512MB - 2988146
Program and configuration memory, plug-in, 512 Mbyte.
Program / configuration memory - SD FLASH 2GB - 2988162
Program and configuration memory, for extending the internal flash memory, pluggable, 2 GB.
Patch cable
10/14/2021 Page 14 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Patch cable - FL CAT5 PATCH 0,5 - 2832263
Patch cable, CAT5, assembled, 0.5 m
Patch cable - FL CAT5 PATCH 1,0 - 2832276
Patch cable, CAT5, assembled, 1 m
Patch cable - FL CAT5 PATCH 2,0 - 2832289
Patch cable, CAT5, assembled, 2 m
PCB plug
PCB connector - FKCN 2,5/ 2-ST GY7035 BD:1-2 - 1082048
PCB connector, color: green, contact surface: Tin, Number of positions per row: 2, product range: FKCN 2,5/..-ST, pitch:
5 mm, type of packaging: packed in cardboard
PCB connector - FKCN 2,5/ 4-ST GY7035 BD:1-4 - 1082059
PCB connector, color: light gray, contact surface: Tin, Number of positions per row: 4, product range: FKCN 2,5/..-ST,
pitch: 5 mm, type of packaging: packed in cardboard
Protective cap
10/14/2021 Page 15 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Dust protection - FL RJ45 PROTECT CAP - 2832991
Dust protection caps for RJ45 socket
SFP module
Media module - FL SFP FX - 2891081
The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100 Mbps with a
wavelength of 1310 nm (long).
Media module - FL SFP FX SM - 2891082
The small form-factor plug-in module provides a fiber optic interface with a data transmission speed of 100 Mbps with a
wavelength of 1310 nm (long).
Media module - FL SFP SX - 2891754
Gigabit SFP module for transmission up to 1 km with a wavelength of 850 nm.
Media module - FL SFP SX2 - 2702397
Gigabit SFP module for transmission up to 2 km with a wavelength of 1310 nm.
10/14/2021 Page 16 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Media module - FL SFP LX10-B - 1025401
Gigabit SFP module for transmission up to 10 km with a wavelength of 1310 nm.
Media module - FL SFP LX - 2891767
Gigabit SFP module for transmission up to 30 km with a wavelength of 1310 nm.
Media module - FL SFP LX40 - 1113081
Gigabit SFP module for transmission up to 40 km with a wavelength of 1310 nm
Media module - FL SFP LH - 2989912
Gigabit SFP module for transmission up to 80 km with a wavelength of 1,550 nm.
Media module - FL SFP WDM10-SET - 2702442
Gigabit SFP WDM set for transmission up to a maximum of 10 km on a single fiber with a wavelength of 1310/1550 nm.
10/14/2021 Page 17 / 18
https://www.phoenixcontact.com/us/products/1088856
Industrial Ethernet Switch - FL SWITCH 2512-2GC-2SFP - 1088856
Accessories
Media module - FL SFP FE WDM20-SET - 2702439
Fast Ethernet SFP WDM set for transmission up to a maximum of 20 km on a single fiber with a wavelength of
1310/1550 nm.
Media module - FL SFP GT - 2989420
Gigabit SFP module for transmission up to 100 m.
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com
10/14/2021 Page 18 / 18