https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Managed Switch 2000, 8 M12 ports 10/100/1000 Mbps, degree of protection: IP65, PROFINET ConformanceClass B
Your advantages
Robust IP67 housing
Easy panel mounting
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4063151001674
Weight per Piece (excluding packing)
1,420.000 g
Custom tariff number
85176200
Country of origin
Germany
Technical data
Dimensions
Width
60 mm
Height
226 mm
Depth
46 mm
Ambient conditions
Degree of protection
IP65
IP66
IP67
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Permissible humidity (operation)
5 % ... 95 %
Permissible humidity (storage/transport)
5 % ... 95 %
10/14/2021 Page 1 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Technical data
Ambient conditions
Air pressure (operation)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Air pressure (storage/transport)
79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
Interfaces
Interface
Ethernet
No. of ports
8 (M12 ports)
Note on the connection method
Auto negotiation and autocrossing
Transmission physics
Copper
Transmission speed
10/100/1000 Mbps
Transmission length
100 m (per segment)
Signal LEDs
Data receive, link status
Function
Basic functions
Store-and-forward switch, complies with IEEE 802.3
Configuration memory
max. 8 GByte (SD card)
Management
Web-based management (HTTP/HTTPS)
Role-based user management
SNMPv1/v2/v3
Command-line interface (Telnet, SSH)
Diagnostic functions
RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance
Filter functions
Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering
Redundancy
MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
10/14/2021 Page 2 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Technical data
Function
LACP (Link Aggregation Control Protocol)
Additional functions
Jumbo frames (max. 9,600 bytes)
Transmission of MMS and GOOSE (IEC 61850-8-1)
Transmission of Modbus TCP
MAC address table
8k
Latency
≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the
frame size)
IP parameterization
DHCP-Client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol)
PROFINET device function
PROFINET device
Fast Startup
PROFINET conformance class
Conformance-Class B
Time synchronization
SNTP (Simple Network Time Protocol)
Status and diagnostic indicators
LEDs: US1, US2 (power supply), Fail, 2 LEDs per Ethernet port (Link/
Activity and Speed)
Network expansion parameters
Cascading depth
Network, linear, and star structure: any
Maximum conductor length (twisted pair)
100 m
Supply voltage
Supply voltage
24 V DC (redundant)
Residual ripple
3.6 VPP (within the permitted voltage range)
Supply voltage range
9 V DC ... 57 V DC
Typical current consumption
260 mA (at US = 24 V DC and 25 °C ambient temperature)
Max. current consumption
0.77 A (US = min, Tamb = max)
Current consumption
260 mA
General
Mounting type
Wall mounting
Type AX
Stand-alone
Net weight
1400 g
Housing material
Zinc die-cast
Note
Support by phone or on-site (fee is charged)
Latency
≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the
frame size)
10/14/2021 Page 3 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Technical data
General
461.15 Years (SN 29500 standard, temperature 25°C, operating
cycle 21%)
MTTF
149.69 Years (SN 29500 standard, temperature 40°C, operating
cycle 34.25%)
19.78 Years (SN 29500 standard, temperature 70°C, operating
cycle 100%)
Connection data
Connection method
M12 connector (A-coded)
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2014/30/EU
Interference emission
EN 61000-6-3 (conducted emissions) Class B
Conducted noise emission
EN 61000-6-3 (conducted emissions) Class B
Immunity to surge
EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
Immunity to burst
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Immunity to EF
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
Immunity to ESD
EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
Immunity to conducted interference
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
Type of test
Free fall in accordance with EN 61131-2
Noise emission
EN 61000-6-3
Noise immunity
EN 61000-6-2
Vibration (storage/transport)
5g, 150 Hz, in acc. with IEC 60068-2-6
Free from substances that could impair the application of coating
Yes
Vibration (operation)
in acc. with IEC 60068-2-6: 5g, 150 Hz
Shock (operation)
30g (EN 60068-2-27)
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Schematic diagram
4
Schematic diagram
4
3
5
3
6
5
2
1
Connection of the supply voltage
2
7
1
8
Assignment of the LAN female connector
10/14/2021 Page 4 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
PIN 1 Us1
PIN 2 GND
Pin 3 GND
Pin 4 Us2
Pin 5 functional ground
Pin 1 DB+
Pin 2 DBPin 3 DA+
Pin 4 DAPin 5 DC+
Pin 6 DCPin 7 DDPin 8 DD+
Classifications
eCl@ss
eCl@ss 10.0.1
19170401
eCl@ss 11.0
19170401
eCl@ss 9.0
19170106
ETIM
ETIM 7.0
EC000734
UNSPSC
UNSPSC 18.0
43222612
UNSPSC 19.0
43222612
UNSPSC 20.0
43222612
UNSPSC 21.0
43222612
Approvals
Approvals
Approvals
EAC / cULus Listed
Ex Approvals
Approval details
EAC
cULus Listed
RU DDE.GB09.B.00312
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 238705
10/14/2021 Page 5 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Accessories
Accessories
Circular connector (cable-side)
Data connector - SACC-PO12MSX-8CT-CL SH - 1021783
Data connector, Ethernet CAT6A (10 Gbps), PROFINET CAT6A (10 Gbps), 8-position, shielded, Plug straight M12 PushPull, Coding: X, Crimp connection, knurl material: PA 6.6, external cable diameter 6.5 mm ... 10 mm, without crimp
contacts
Data connector - SACC-PO12MSD-4CT-CM SH PN - 1021830
Data connector, PROFINET CAT5 (100 Mbps), 4-position, shielded, Plug straight M12 Push-Pull, Coding: D, Crimp
connection, knurl material: PA 6.6, external cable diameter 4.5 mm ... 7.5 mm, without crimp contacts
Data cable preassembled
Network cable - NBC-M12MRX/1,0-94F/M12MRX - 1080720
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021,
shielded (Advanced Shielding Technology), Plug angled M12 / IP67, coding: X, on Plug angled M12 / IP67, coding: X,
cable length: 1 m
Network cable - NBC-M12MRX/2,0-94F/M12MRX - 1080721
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021,
shielded (Advanced Shielding Technology), Plug angled M12 / IP67, coding: X, on Plug angled M12 / IP67, coding: X,
cable length: 2 m
10/14/2021 Page 6 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Accessories
Network cable - NBC-M12MSX/ 1,0-94C/M12MSX - 1125028
Network cable, Ethernet CAT5 (1 Gbps) CAT5 (1 Gbps), 8-position, PUR, water blue RAL 5021, shielded (Advanced
Shielding Technology), Plug straight M12 / IP67, coding: X, on Plug straight M12 / IP67, coding: X, cable length: 1 m
Network cable - NBC-M12MSX/1,0-94F/M12MRX - 1080724
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021,
shielded (Advanced Shielding Technology), Plug straight M12 / IP67, coding: X, on Plug angled M12 / IP67, coding: X,
cable length: 1 m
Network cable - NBC-M12MSX/2,0-94F/M12MRX - 1080725
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021,
shielded (Advanced Shielding Technology), Plug straight M12 / IP67, coding: X, on Plug angled M12 / IP67, coding: X,
cable length: 2 m
Network cable - NBC-M12MSX/5,0-94F/M12MRX - 1080726
Network cable, Ethernet CAT6A (10 Gbps) CAT6A (10 Gbps), 8-position, PUR halogen-free, water blue RAL 5021,
shielded (Advanced Shielding Technology), Plug straight M12 / IP67, coding: X, on Plug angled M12 / IP67, coding: X,
cable length: 5 m
Drivers and interfaces
Software - FL SNMP OPC SERVER V3 - 2701139
SNMP-OPC server, German and English, for monitoring and configuration of SNMP-capable equipment in HMI and
SCADA systems
10/14/2021 Page 7 / 8
https://www.phoenixcontact.com/us/products/1106615
Industrial Ethernet Switch - FL SWITCH 2708 - 1106615
Accessories
Network management software
Software - FL NETWORK MANAGER BASIC - 2702889
FL Network Manager, SNMP-based configuration and firmware update software, for easy startup of Managed Switches
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com
10/14/2021 Page 8 / 8