0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1110155

1110155

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    UNO2-PS/1AC/48DC/240W

  • 数据手册
  • 价格&库存
1110155 数据手册
Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. Primary-switched power supply unit, UNO POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 48 V DC / 5 A Your advantages • Save space in the control cabinet with an extremely narrow overall width of just 45 mm • Save energy, thanks to a high degree of efficiency • Outdoor installation possible, with a wide temperature range of -25°C … +70°C • Simple output voltage monitoring, thanks to the floating DC OK relay contact May 19, 2022, 10:06 AM Page 1 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Commercial Data Item number 1110155 Packing unit 1 pc Minimum order quantity 1 pc Product Key CMPV14 GTIN 4063151024840 Weight per Piece (including packing) 857 g Weight per Piece (excluding packing) 855 g Customs tariff number 85044030 Country of origin TH May 19, 2022, 10:06 AM Page 2 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Technical Data Input data Supply system configuration Star network (TN, TT, IT (PE)) Nominal input voltage range 100 V AC ... 240 V AC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % Derating < 90 V AC (1 %/V) Typical national grid voltage 120 V AC 230 V AC Voltage type of supply voltage AC Inrush current 10 A Inrush current integral (I2t) < 0.05 A2s Inrush current limitation < 20 A (at 25 °C) Frequency range (fN) 50 Hz ... 60 Hz ±10 % Mains buffering time typ. 20 ms (120 V AC) typ. 20 ms (230 V AC) Current consumption 2.6 A (100 V AC) 2.2 A (120 V AC) 1.16 A (230 V AC) 1.2 A (240 V AC) Protective circuit Transient surge protection; Varistor, gas-filled surge arrester Switch-on time typ. 530 ms Device mains fuse 5 A internal (device protection), fast-blow Recommended breaker for input protection 10 A ... 16 A (Characteristic B, C, D, K or comparable) Discharge current to PE < 3.5 mA Output data Efficiency typ. 91.5 % (120 V AC) typ. 93 % (230 V AC) Nominal output voltage 48 V DC Setting range of the output voltage (USet) 42 V DC ... 56 V DC (≥48 V DC, constant capacity restricted 550000 h (40 °C) > 280000 h (55 °C) Environmental protection directive RoHS Directive 2011/65/EU WEEE Reach Insulation characteristics Protection class I Degree of pollution 2 May 19, 2022, 10:06 AM Page 5 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Dimensions Dimensional drawing Width 45 mm Height 130 mm Depth 125 mm (Device depth (DIN rail mounting)) Depth 129 mm Installation dimensions Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≥50% ) Installation distance top/bottom (active, passive) 30 mm / 30 mm (POut ≥50% ) Mounting Mounting type DIN rail mounting Assembly instructions alignable: 0 mm horizontally, 30 mm vertically Mounting position horizontal DIN rail NS 35, EN 60715 With protective coating No Material specifications Flammability rating according to UL 94 V0 (Housing, terminal blocks) Housing material Metal Hood version Stainless steel Side element version Aluminum Foot latch material Sheet steel, zinc-plated Housing material Aluminum (AlMg3) / sheet steel, zinc-plated Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K) Ambient temperature (storage/transport) -40 °C ... 85 °C Ambient temperature (start-up type tested) -40 °C Maximum altitude ≤ 3000 m (> 2000 m, Derating: 10 %/1000 m) Climatic class 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Shock (operation) 18 ms, 30g, per spatial direction (IEC 60068-2-27) Vibration (operation) 10 Hz ... 50 Hz, amplitude ±0.2 mm May 19, 2022, 10:06 AM Page 6 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 50 Hz to 150 Hz, 2.3 g, 90 min. Standards and regulations Overvoltage category EN 61010-1 II (≤ 3000 m) Overvoltage category EN 62477-1 III (≤3000 m)  Safety of power supply units up to 1100 V (insulation distances) Standards/specifications DIN EN 61558-2-16 Electrical safety Standards/specifications IEC 61010-2-201 (SELV) Electronic equipment for use in power installations Standards/specifications EN 50178/VDE 0160 (PELV) Safety for measurement, control, and laboratory equipment Standards/specifications IEC 61010-1 Protective extra-low voltage Standards/specifications IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Safe isolation Standards/specifications IEC 61558-2-16 IEC 61010-2-201 Limitation of harmonic line currents Standards/specifications EN 61000-3-2 Mains voltage dips Standards/specifications SEMI F47 - 0706 (185 V AC) Approval data UL Identification UL/C-UL Listed UL 61010-1 UL Identification UL/C-UL Listed UL 61010-2-201 UL Identification UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) SIQ Identification CB scheme (IEC 61010-1, IEC 61010-2-201) May 19, 2022, 10:06 AM Page 7 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 EMC data Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU EMC requirements for noise immunity EN 61000-6-2 Conducted noise emission EN 55016 EN 61000-6-3 (Class B) Interference emission Noise emission according to EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) Noise emission EN 55016 EN 61000-6-3 (Class B) Noise immunity EN 61000-6-2:2005 Harmonic currents Standards/regulations EN 61000-3-2 EN 61000-3-2 (Class A) Frequency range 0 kHz ... 2 kHz Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Contact discharge 6 kV (Test Level 3) Discharge in air 8 kV (Test Level 3) Comments Criterion A Electromagnetic HF field Standards/regulations EN 61000-4-3 Electromagnetic HF field Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) Standards/regulations EN 61000-4-4 Fast transients (burst) Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Surge voltage load (surge) Standards/regulations EN 61000-4-5 May 19, 2022, 10:06 AM Page 8 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Input 2 kV (Test Level 3 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Comments Criterion A Conducted interference Standards/regulations EN 61000-4-6 Conducted interference Input/Output asymmetrical Frequency range 0.15 MHz ... 80 MHz Comments Criterion A Voltage 10 V (Test Level 3) Voltage dips Standards/regulations EN 61000-4-11 Voltage 230 V AC Frequency 50 Hz Voltage dip 70 % Number of periods 25 / 30 periods Comments Criterion A Voltage dip 40 % Number of periods 12 periods Additional text Test Level 2 Comments Criterion A Voltage dip 0% Number of periods 1 period Additional text Test Level 2 Comments Criterion B Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. May 19, 2022, 10:06 AM Page 9 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Drawings Power Factor Diagram 1,1 1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0    = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC 1 2 3 4 5 IOut [A] POut [%] Diagram 120 110 100 90 80 70 60 50 PN 100% ≤ 50°C 0 1000 2000 3000 4000 5000 H [m] May 19, 2022, 10:06 AM Page 10 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Dimensional drawing UNO POWER Ord.No.1110155 45 3.1 3.2 2.1 2.2 2.3 2.4 13 + + 14 Output DC 48V 240W 42-56 V 130 DC OK Input AC 100-240V L N 1.1 1.2 1.3 May 19, 2022, 10:06 AM Page 11 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Dimensional drawing 130 48 80 130 125 Block diagram Input AC  1.1 L 1.2 N 1.3 Output DC Filter aktive PFC Filter 2.2 + 2.3 2.4 Signal Functions UVP 2.1 OVP 3.1 3.2 13 14 User Interface OTP OCP SCP UOUT DC OK May 19, 2022, 10:06 AM Page 12 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Eta [%] Diagram 96 95 94 93 92 91 90 89 88 87 86 1   = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC  2 3 4 5 IOut [A] IIn [A] Diagram 2,5 2   1,5 1 0,5 0 0  = UIn: 120 V AC/UOut : 48 V DC  = UIn: 230 V AC/UOut : 48 V DC 1 2 3 4 5 IOut [A] May 19, 2022, 10:06 AM Page 13 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Approvals  EAC Approval ID: RU S-DE.BL08.W.00764 May 19, 2022, 10:06 AM Page 14 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Classifications ECLASS ECLASS-11.0 27040701 ETIM ETIM 8.0 EC002540 UNSPSC UNSPSC 21.0 May 19, 2022, 10:06 AM Page 15 (16) Power supply unit - UNO2-PS/1AC/48DC/240W 1110155 https://www.phoenixcontact.com/in/products/1110155 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com PHOENIX CONTACT (I) Pvt. Ltd. A-58/2, Okhla Industrial Area, Phase - II, New Delhi-110 020 +91.1275.71420 info@phoenixcontact.co.in May 19, 2022, 10:06 AM Page 16 (16)
1110155 价格&库存

很抱歉,暂时无法提供与“1110155”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1110155
    •  国内价格
    • 1+799.87865

    库存:3

    1110155
      •  国内价格 香港价格
      • 1+713.471231+85.81068
      • 100+697.45829100+83.88477

      库存:15