1119820

1119820

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    4 接线板 - 线至板 水平,带板 0.591"(15.00mm) 通孔

  • 数据手册
  • 价格&库存
1119820 数据手册
2021-02-23 Product version 00 Data sheet Document revision 00 Order No.: 1119820 Type: LPT 16/ 4-15,0-ZB Main features      No. of pos. Conductor cross section Color Pitch Connection method 4 16 mm² green (6021) 15 mm Lever Push-in connection     Nominal current Nominal voltage Connection direction Type of packaging 76 A 1000 V 0° packed in cardboard   1   PCB terminal block, Lever Push-in connection Your advantages   Tool-free lever principle enables time-saving connection and release of conductors with/without ferrules Clear lever positions provide reliable feedback on opened or closed clamping spaces Defined contact force ensures that contact remains stable over the long term Time-saving push-in connection when lever is closed Intuitive operation, thanks to a color-coded actuation lever Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.net/product/1119820 © PHOENIX CONTACT 2021 2 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB Document revision 00 Table of contents 1 Main features........................................................................................................................... 1 2 Your advantages ..................................................................................................................... 1 3 Table of contents ..................................................................................................................... 2 4 3D model in PDF can be activated (Acrobat Reader only)....................................................... 3 5 General Technical Data ........................................................................................................... 4 6 Conductor connection ............................................................................................................. 5 7 Material properties................................................................................................................... 5 8 Dimensions.............................................................................................................................. 6 9 Series drawing......................................................................................................................... 7 10 Application............................................................................................................................... 8 11 Packaging information ............................................................................................................. 8 12 Mechanical tests...................................................................................................................... 9 13 Electrical tests ....................................................................................................................... 10 14 Current carrying capacity/derating curves ............................................................................. 12 15 Environmental and durability tests ......................................................................................... 13 16 Commercial Data................................................................................................................... 14 REF PHOENIX CONTACT 2 / 14 © PHOENIX CONTACT 2021       3 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 3D model in PDF can be activated (Acrobat Reader only) © PHOENIX CONTACT 2021       4 Document revision 00 REF PHOENIX CONTACT 3 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 5 General Technical Data 5.1 item properties Document revision 00 Order No. 1119820 Type LPT 16/ 4-15,0-ZB Product type PCB terminal block Range of articles LPT 16/ Pitch 15 mm Number of positions 4 Number of levels 1 Number of connections 4 Number of potentials 4 Connection method Lever Push-in connection Wave soldering Connection direction of the conductor to the PCB 0° Pin layout Zigzag pinning W © PHOENIX CONTACT 2021       Mounting type REF PHOENIX CONTACT 4 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 6 Conductor connection 6.1 Connection capacity Conductor cross section, rigid Document revision 00 0.75 mm² ... 16 mm² (Conductor connection with open terminal point) Conductor cross section, rigid 1.5 mm² ... 16 mm² (Push-in connection) Conductor cross section, multi-stranded 0.75 mm² ... 16 mm² Conductor cross section, flexible 0.75 mm² ... 25 mm² Conductor cross section flexible, with ferrule without plastic sleeve 0.75 mm² ... 16 mm² Conductor cross section flexible, with ferrule with plastic sleeve 0.75 mm² ... 16 mm² 2 conductors with the same cross section flexible with TWIN ferrule and plastic sleeve 4 mm² ... 6 mm² Stripping length 18 mm ... 20 mm Connection capacity AWG Conductor cross section AWG 7 Material properties 7.1 Material of metal parts 18 ... 4 WEEE/RoHS-compliant, whisker-free acc. to IEC 60068-2-82/JEDEC JESD 201 Contact material Cu alloy Terminal point surface Tin (10 - 16 µm Sn) Soldering area surface Tin (10 - 16 µm Sn) Surface characteristics Tin-plated 7.2   Note Material of plastic parts Housing Actuation element green (6021) orange (2003) Insulating material PA PA GF Insulating material group I I CTI according to IEC 60112 600 600 Flammability rating according to UL 94 V0 V0 850 Glow wire ignition temperature GWIT according to EN 60695-2-13 775 Temperature for the ball pressure test according to EN 60695-10-2 125 °C © PHOENIX CONTACT 2021 Glow wire flammability index GWFI according to EN 60695-2-12   Color   6.2 REF PHOENIX CONTACT 5 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 8 Dimensions 8.1 Dimensions for the product Document revision 00 Length 32 mm Width 56.9 mm 36 mm Total height 39.6 mm Solder pin [P] 3.6 mm © PHOENIX CONTACT 2021       Height (without solder pin) REF PHOENIX CONTACT 6 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB Series drawing © PHOENIX CONTACT 2021       9 Document revision 00 REF PHOENIX CONTACT 7 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 10 Application 11 Packaging information Document revision 00 Type of packaging packed in cardboard Pieces per package 25 11.1 Temperature limit values -40 °C ... 70 °C Ambient temperature (assembly) -5 °C ... 100 °C Ambient temperature (operation) -40 °C ... 105 °C (Depending on the current carrying capacity/derating curve) © PHOENIX CONTACT 2021       Ambient temperature (storage/transport) REF PHOENIX CONTACT 8 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 12 Mechanical tests 12.1 Pull-out test Document revision 00 Specification IEC 60999-1:1999-11 Result Test passed Conductor cross section/conductor type/tractive force actual value 0.75 mm² / solid / > 30 N Conductor cross section/conductor type/tractive force actual value 0.75 mm² / flexible / > 30 N Conductor cross section/conductor type/tractive force actual value 16 mm² / solid / > 100 N Conductor cross section/conductor type/tractive force actual value 25 mm² / flexible / > 135 N 12.2 Check for damage to conductor or loosening IEC 60999-1:1999-11 Result Test passed © PHOENIX CONTACT 2021       Specification REF PHOENIX CONTACT 9 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 13 Electrical tests 13.1 Electrical data Rated current / conductor cross section Document revision 00 76 A / 16 mm² Rated insulation voltage (III/2) 1000 V Rated surge voltage (III/2) 8 kV Contact resistance 0.38 mΩ Degree of pollution 2 13.2 Air and creepage distances Component PCB terminal block Specification IEC 60947-7-4:2019-01 Mains type unearthed mains Insulating material group I Comparative tracking index (IEC 60112:2003-01) CTI 600 Rated insulation voltage 1000 V 1000 V 1000 V Rated surge voltage 8 kV 8 kV 6 kV Degree of pollution 3 2 2 Overvoltage category III III II Minimum clearance case A (inhomogeneous field) 8 mm 8 mm 5.5 mm Minimum value of the creepage path requirement in acc. with table 12.5 mm 8 mm 5.5 mm Short-time withstand current test   13.3 IEC 60947-7-4:2019-01 Result Test passed Conductor cross section/short-time current 16 mm² / 360 A   Specification Specification IEC 60947-7-4:2019-01 Result Test passed Contact resistance R1 0.38 mΩ / 16 mm² Test sequence 1: low temperature storage -40 °C / 2 h Test sequence 2: heat storage 168 h/105 °C Test sequence 3: noxious gas storage (ISO 6988) KFW 0.2 S/1 cycle Contact resistance R2 0.2 mΩ / 16 mm² Rated impulse voltage at sea level Voltage waveform ≥ (1.2/50 μs) 9.8 kV Power-frequency withstand voltage Voltage waveform ≥ (50/60 Hz) 4.2 kV 13.5 REF   Aging test (climatic impact and corrosion testing) © PHOENIX CONTACT 2021 13.4 Insulation resistance PHOENIX CONTACT 10 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB Document revision 00 Specification IEC 60512-3-1:2002-02 Result Test passed Insulation resistance, neighboring positions > 5 MΩ 13.6 Mechanical connection test for the PCB terminal block Specification IEC 60947-7-4:2019-01 Result Test passed 13.7 Temperature rise test Specification IEC 60947-7-4:2019-01 Result Test passed Requirement temperature-rise test The sum of ambient temperature and temperature rise of the PCB terminal block shall not exceed the upper limiting temperature. 16 mm² / 76 A / 41.7 K 10 mm² / 57 A / 33.7 K Conductor cross section/test current/temperature rise 6 mm² / 41 A / 30.2 K © PHOENIX CONTACT 2021       Conductor cross section/test current/temperature rise Conductor cross section/test current/temperature rise REF PHOENIX CONTACT 11 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 14 Document revision 00 Current carrying capacity/derating curves Specification IEC 60947-7-4:2019-01 Note Representation based on IEC 60512-5-2:2002-02 Reduction factor 1 Number of positions 4 Conductor cross section 16 mm² I [A] Type: LPT 16/...-15,0-ZB 130 120 110 100 90 80 70 60 50 40 30 20 10 0 1 2 3 2 = 16 mm 2 = 10 mm 2 = 6 mm 1 2 3 0 10 20 30 40 50 60 70 80 90 100 110 © PHOENIX CONTACT 2021       ă [°C] REF PHOENIX CONTACT 12 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 15 Environmental and durability tests 15.1 Vibration test Document revision 00 Specification IEC 60068-2-6:2007-12 Result Test passed Frequency 10 - 150 - 10 Hz Sweep speed 1 octave/min Amplitude 0.35 mm (10 - 60.1 Hz) Acceleration 50 m/s2 (60.1 - 150 Hz) Test duration per axis 2.5 h Test directions X-, Y- and Z-axis Note 15.2 Assessment of fire risk (glow wire test) Specification IEC 60695-2-10:2013-04 Result Test passed Temperature 850 °C Time of exposure 5s 15.3 Shock protection Following IEC 60529:1989-11 + AMD 1:1999-11 + AMD 2:2013-08 Back of the hand protection (Ball ø 50) conditional guaranteed Finger protection (movable test finger) conditional guaranteed Note Contact protection above the PCB is only assured when a conductor with a crosssection of 6 mm² is connected. © PHOENIX CONTACT 2021       Specification REF PHOENIX CONTACT 13 / 14 2021-02-23 Product version 00 1119820 LPT 16/ 4-15,0-ZB 16 Document revision 00 Commercial Data Order No. 1119820 Type LPT 16/ 4-15,0-ZB Pieces per package 25 Net weight 2.22 g GTIN 4063151065676 Information that applies locally, see link on page 1 Information that applies locally, see link on page 1 © PHOENIX CONTACT 2021       Country of origin REF PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany phoenixcontact.com PHOENIX CONTACT 14 / 14
1119820 价格&库存

很抱歉,暂时无法提供与“1119820”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1119820
  •  国内价格 香港价格
  • 1+135.781171+16.84359
  • 10+133.9494510+16.61637
  • 25+132.2243625+16.40237
  • 50+106.4828950+13.20916
  • 100+102.25989100+12.68529

库存:297