0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1140066

1140066

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    AC/DC DIN RAIL SUPPLY 24V 96W

  • 数据手册
  • 价格&库存
1140066 数据手册
https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched power supply unit, STEP POWER, Push-in technology, DIN rail mounting, input: 1-phase, output: 24 V DC / 4 A Product Description STEP POWER power supplies for distribution boards The STEP POWER power supply range was developed especially for building automation. The low idling losses and high degree of efficiency ensure maximum energy efficiency. They allow flexible use and can be snapped onto the DIN rail or screwed onto an even surface. Key Commercial Data Packing unit 1 pc GTIN GTIN 4063151089115 Weight per Piece (excluding packing) 255.000 g Custom tariff number 85044030 Country of origin Vietnam Technical data Dimensions Width 72 mm Height 90 mm Depth 55 mm Horizontal pitch 4 Div. (DIN 43880) Installation distance top/bottom 30 mm / 30 mm Ambient temperature (operation) -10 °C ... 70 °C (Derating: > 50 °C; 2 %/K) Ambient temperature (start-up type tested) -25 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing) Maximum altitude ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) 06/17/2020   Page 1 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Technical data Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) 15 Hz ... 150 Hz, 2.3g, 90 min. Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Degree of pollution 2 Climatic class 3K3 (EN 60721) Overvoltage category (EN 61010-1) II (≤ 4000 m) Overvoltage category (EN 62477-1) III (≤ 2000 m) Input data Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 110 V DC ... 250 V DC -10 % ... +40 % Derating < 100 V AC ... 85 V AC (1 %/V) < 110 V DC ... 88 V DC (1 %/V) Frequency range (fN) 50 Hz ... 60 Hz ±10 % Typical national grid voltage 120 V AC 230 V AC Voltage type of supply voltage AC/DC Network type Star network Current consumption 1.07 A (100 V AC) 0.47 A (240 V AC) 0.97 A (110 V DC) 0.41 A (250 V DC) Discharge current to PE < 0.25 mA Mains buffering time typ. 20 ms (120 V AC) typ. 20 ms (230 V AC) Switch-on time typ. 2 s Inrush current typ. 37 A 2 2 Inrush current integral (I t) typ. 0.4 A s Type of protection Transient surge protection Protective circuit/component Varistor Device mains fuse 4 A internal (device protection), slow-blow Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K) Output data Nominal output voltage 24 V DC Setting range of the output voltage (USet) 22 V DC ... 27 V DC (> 24 V DC, constant capacity restricted) Nominal output current (IN) 4A Control deviation < 0.5 % (Static load change 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, (10 Hz)) < 0.1 % (change in input voltage ±10 %) Short-circuit-proof yes No-load proof yes 06/17/2020   Page 2 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Technical data Output data Residual ripple typ. 150 mVPP Connection in parallel yes, for increasing power and redundancy with diode Connection in series yes, for increased efficiency Feedback voltage resistance ≤ 35 V DC Protection against overvoltage at the output (OVP) < 35 V DC Rise time typ. 100 ms (UOut = 10 % ... 90 %) Derating > 50 °C ... 70 °C (2.5%/K) Crest factor typ. 1.74 typ. 2.08 Output power 96 W Minimum no-load power dissipation < 0.21 W (120 V AC) Maximum power dissipation in no-load condition < 0.21 W (230 V AC) Minimum nominal load power dissipation < 7 W (120 V AC) Power loss nominal load max. < 5.7 W (230 V AC) General Net weight 255 g Efficiency > 93 % (120 V AC) > 94 % (230 V AC) MTBF (IEC 61709, SN 29500) > 1350000 h (25 °C) > 750000 h (40 °C) > 488000 h (50 °C) Insulation voltage input/output 4 kV AC (type test) 3.75 kV AC (routine test) Degree of protection IP20 Protection class II (in closed control cabinet) Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Efficiency Level VI Housing material Polycarbonate Foot latch material Polyamid Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: 0 mm horizontally, 30 mm vertically Input connection data Connection method Push-in technology Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 1 mm² Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.5 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 (Cu) 06/17/2020   Page 3 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Technical data Output connection data Connection method Push-in technology Stripping length 10 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 1 mm² Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.5 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 (Cu) LED signaling Types of signaling LED UOut > 0,9 x UN (UN = 24 V DC) (LED lights up green) < 0,9 x UN (UN = 24 V DC) (LED off) Standards Standard designation Electrical safety Standards/regulations IEC 61010-1 (SELV) Standard designation Safety extra-low voltage Standards/regulations IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Standard designation Safe isolation Standards/regulations IEC 61558-2-16 Standard designation Low-voltage power supplies, DC output Standards/regulations EN 61204-3 Standard designation Safety requirements for electrical equipment for measurement, control, and laboratory use Standards/regulations IEC 61010-1 Standard designation Safety of electrical devices for household use and similar purposes Standards/regulations DIN EN 60335-1 Conformance/approvals Designation UL Identification UL/C-UL Listed UL 61010-1 Designation UL Identification UL/C-UL Listed UL 61010-2-201 Designation UL Identification UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Conducted noise emission EN 55016 EN 61000-6-3 (Class B) 06/17/2020   Page 4 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Technical data EMC data Noise emission EN 55016 EN 61000-6-3 (Class B) Harmonic currents EN 61000-3-2 EN 61000-3-2 (Class A) Flicker EN 61000-3-3 Electrostatic discharge EN 61000-4-2 Contact discharge 6 kV (Test Level 3) Discharge in air 8 kV (Test Level 3) Electromagnetic HF field EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 6 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN 61000-4-4 Input asymmetrical 4 kV (Test Level 4) Output asymmetrical 2 kV (Test Level 3) Comments Criterion A Surge voltage load (surge) EN 61000-4-5 Input symmetrical 2 kV (Test Level 4) asymmetrical 4 kV (Test Level 4) Output symmetrical 1 kV (Test Level 3) asymmetrical 2 kV (Test Level 3) Comments Criterion A Conducted interference EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Voltage dips EN 61000-4-11 Voltage 230 V AC Frequency 50 Hz Voltage dip 70 % Number of periods 25 periods Additional text Class 3 Comments Criterion A Voltage dip 40 % Number of periods 10 periods Additional text Class 3 Comments Criterion B Voltage dip 0% 06/17/2020   Page 5 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Technical data EMC data Number of periods 1 period Additional text Class 3 Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. Drawings Block diagram 06/17/2020   Page 6 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Diagram Diagram 06/17/2020   Page 7 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Diagram Diagram 06/17/2020   Page 8 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Dimensional drawing 06/17/2020   Page 9 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Dimensional drawing 06/17/2020   Page 10 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Schematic diagram Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 9.0 27040701 Approvals Approvals Approvals cULus Listed Ex Approvals cULus Listed Approval details cULus Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 123528 06/17/2020   Page 11 / 12 https://www.phoenixcontact.com/in/products/1140066 Power supply unit - STEP3-PS/1AC/24DC/4/PT - 1140066 Accessories Accessories Redundancy module Redundancy module - STEP-DIODE/5-24DC/2X5/1X10 - 2868606 Redundancy module, 5 ... 24 V DC, 2x 5 A, 1x 10 A     Closing cap - STEP3 SEALING PLUG - 1175957 Sealing plug for protection against manipulation (adjustment of the DC output voltage) by sealing off the potentiometer opening     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/17/2020   Page 12 / 12
1140066 价格&库存

很抱歉,暂时无法提供与“1140066”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1140066
    •  国内价格
    • 1+519.49427

    库存:1