  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    电容性 智能,智慧,发光二极管,图形 TFT - 彩色 以太网,USB 7"(177.80mm) 1280 x 800(WXGA)

  • 数据手册
  • 价格&库存
1148693 数据手册
Web Panels with TFT Display User manual User manual Web Panels with TFT Display UM EN WP 4XXXX, Revision 04 2020-04-01 This user manual is valid for: Order No. WP 4000 WP 4070W/P US 01 WP 4101W/P US 01 WP 4156W/P US 01 WP 4185W/P US 01 WP 4070-WXPS WP 4070-WVRS WP 4101-WXPS WP 4120-WXPS WP 4156-WHPS WP 4185-WHPS 1065546 1094819 1094818 1104387 1104395 1148693 1148694 1148687 1148689 1148691 1148690 108594_en_04 Designation PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com How to contact us Internet Up-to-date information on Phoenix Contact products and our Terms and Conditions can be found on the Internet at: phoenixcontact.com Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.net/products Subsidiaries If there are any problems that cannot be solved using the documentation, please contact your Phoenix Contact subsidiary. Subsidiary contact information is available at phoenixcontact.com. Published by PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg GERMANY Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to tecdoc@phoenixcontact.com General terms and conditions of use for technical documentation Phoenix Contact reserves the right to alter, correct, and/or improve the technical documentation and the products described in the technical documentation at its own discretion and without giving prior notice, insofar as this is reasonable for the user. The same applies to any technical changes that serve the purpose of technical progress. The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations. All information made available in the technical data is supplied without any accompanying guarantee, whether expressly mentioned, implied or tacitly assumed. In general, the provisions of the current standard Terms and Conditions of Phoenix Contact apply exclusively, in particular as concerns any warranty liability. This manual, including all illustrations contained herein, is copyright protected. Any changes to the contents or the publication of extracts of this document is prohibited. Phoenix Contact reserves the right to register its own intellectual property rights for the product identifications of Phoenix Contact products that are used here. Registration of such intellectual property rights by third parties is prohibited. Other product identifications may be afforded legal protection, even where they may not be indicated as such. PHOENIX CONTACT PHOENIX CONTACT Table of Contents Table of Contents 1 2 3 4 Important Notes .........................................................................................................................7 1.1 Symbols ................................................................................................................ 7 1.2 Safety Notes.......................................................................................................... 7 1.3 Security in the network .......................................................................................... 8 1.4 Intended Use ......................................................................................................... 8 1.5 Target Group ......................................................................................................... 9 1.6 Licensing information on open source software..................................................... 9 1.7 Retrieving the source code .................................................................................... 9 Installation and Commissioning ...............................................................................................11 2.1 Unpacking the Device.......................................................................................... 11 2.2 Mounting the Device............................................................................................ 12 2.2.1 Front Panel Dimensions ....................................................................... 13 2.2.2 Mounting Cutout .................................................................................. 19 2.2.3 Side View, Mounting Depth .................................................................. 25 2.3 Connecting the Device ........................................................................................ 31 2.3.1 Supply Voltage ..................................................................................... 31 2.3.2 Grounding ............................................................................................ 32 2.4 Switching On ....................................................................................................... 33 2.5 Identification ........................................................................................................ 33 2.5.1 Orderkey .............................................................................................. 33 Control and Display Elements ..................................................................................................35 3.1 Touchscreen ....................................................................................................... 35 3.2 Display................................................................................................................. 35 3.3 Status LEDs......................................................................................................... 36 Interfaces of the Device ...........................................................................................................37 4.1 5 Standard Interfaces ............................................................................................. 37 4.1.1 Ethernet (X5) ........................................................................................ 38 4.1.2 USB (X9, X10) ..................................................................................... 39 4.1.3 Memory Card ....................................................................................... 40 Maintenance and Servicing ......................................................................................................41 108594_en_04 5.1 Front Panel .......................................................................................................... 41 5.2 Fuse .................................................................................................................... 41 PHOENIX CONTACT 5 WP 4000 6 6 Technical Data .........................................................................................................................43 PHOENIX CONTACT 6.1 General................................................................................................................ 43 6.2 7" Display (resistive) ............................................................................................ 45 6.3 7" Display (PCAP) ............................................................................................... 47 6.4 10.1" Display (PCAP) .......................................................................................... 49 6.5 12.1" Display (PCAP) .......................................................................................... 51 6.6 15.6" Display (PCAP) .......................................................................................... 53 6.7 18.5" Display (PCAP) .......................................................................................... 55 108594_en_04 Important Notes 1 Important Notes 1.1 Symbols The symbols in this manual are used to draw your attention on notes and dangers. This symbol indicates hazards that could lead to personal injury. There are three signal words indicating the severity of a potential injury. DANGER Indicates a hazard with a high risk level. If this hazardous situation is not avoided, it will result in death or serious injury. WARNING Indicates a hazard with a medium risk level. If this hazardous situation is not avoided, it could result in death or serious injury. CAUTION Indicates a hazard with a low risk level. If this hazardous situation is not avoided, it could result in minor or moderate injury. This symbol together with the NOTE signal word alerts the reader to a situation which may cause damage or malfunction to the device, hardware/software, or surrounding property. Here you will find additional information or detailed sources of information. 1.2 – – – – – – 108594_en_04 Safety Notes Read this manual carefully before using the operating device. Keep this manual in a place where it is always accessible to all users. Proper transportation, handling and storage, placement and installation of this product are prerequisites for its subsequent flawless and safe operation. This user manual contains the most important information for the safe operation of the device. The user manual, in particular the safety notes, must be observed by all personnel working with the device. Observe the accident prevention rules and regulations that apply to the operating site. Installation and operation must only be carried out by qualified and trained personnel. PHOENIX CONTACT 7 WP 4000 1.3 Security in the network NOTE: Risk of unauthorized network access Connecting devices to a network via Ethernet always entails the risk of unauthorized access to the network. Therefore, please check your application for any option of deactivating active communication channels . Setting passwords to prevent third parties from accessing the controller without authorization and modifying the system. Because of the controller's communication interfaces, we advise against using the controller in safety-critical applications without additional security appliances. Please take additional protective measures according to the IT security requirements and the standards applicable to your application (for instance virtual networks (VPN) for remote maintenance access, firewalls, etc.) for protection against unauthorized network access. On first request, you shall release Phoenix Contact and the companies associated with Phoenix Contact GmbH & Co. KG, Flachsmarktstraße 8, 32825 Blomberg in accordance with §§ 15 ff. AktG or German Stock Corporation Act (hereinafter collectively referred to as "Phoenix Contact") from all third-party claims that are made due to improper use. For the protection of networks for remote maintenance via VPN, Phoenix Contact offers the mGuard product series security appliances which you can find described in the latest Phoenix Contact catalog (phoenixcontact.net/products). Additional measures for protection from unauthorized network access can be found in the AH EN INDUSTRIAL SECURITY application note. The application note can be downloaded at phoenixcontact.net/products. 1.4 – – – Intended Use The device is designed for use in the industry. The device is state-of-the art and has been built to the latest standard safety requirements. However, dangerous situations or damage to the machine itself or other property can arise from the use of this device. The device fulfills the requirements of the EMC directives and harmonized European standards. Any modifications to the system can influence the EMC behavior. NOTICE: Radio Interference Operation of this device may cause radio interference in residential areas. 8 PHOENIX CONTACT 108594_en_04 Important Notes 1.5 Target Group The use of products described in this manual is oriented exclusively to: – Qualified electricians or persons instructed by them. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. – Qualified application programmers and software engineers. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. 1.6 Licensing information on open source software The operating device works with a Linux operating system. License information for the individual Linux packages can be found in the web-based management of the operating device. 1.7 Retrieving the source code This product contains software components which are licensed by the rights holder as free software or Open-source software under the GNU General Public License, version 2. You may retrieve the source code for these software components from Phoenix Contact using an appropriate storage medium (CD or DVD-ROM), by contacting After Sales Service at the address below. This must be carried out no more than three years after delivery of the product. A processing charge of 50 euros will be required in this case. PHOENIX CONTACT GmbH & Co. KG After Sales Service Flachsmarktstraße 8 32825 Blomberg GERMANY Subject: Source code WP 4XXXX 108594_en_04 PHOENIX CONTACT 9 WP 4000 10 PHOENIX CONTACT 108594_en_04 Installation and Commissioning 2 Installation and Commissioning 2.1 Unpacking the Device Unpack all parts carefully and check the contents for any visible damage in transit. Also check whether the shipment matches the specifications on your delivery note. If you notice damages in transit or discrepancies, please contact us immediately. 108594_en_04 PHOENIX CONTACT 11 WP 4000 2.2 Mounting the Device NOTICE: Damage When installing the device, leave a gap of at least 30 mm (1.181") around the device to ensure sufficient air circulation. NOTICE: Damage When the operating device is installed horizontally, please note that additional sources of heat beneath the operating device may result in heat accumulation. Make sure to allow sufficient heat dissipation! Please observe the permissible temperature range specified in the technical data when operating the device. NOTICE: Damage In order to ensure the degree of protection specified in the technical data, observe the following points: – A tolerance of ±0.5 mm is maintained for the mounting cutout. – The seal lies flat against the mounting surface. – The number of mounting brackets, given in the technical data, is used. – The material of the mounting surface is sufficiently stable to ensure permanently secure attachment of the operating device. – The mounting surface and the operating device may not become deformed due to the effects of the mounting clamps or through the operation of the device. – The threaded pins of the mounting brackets are tightened uniformly to a maximum torque of 1 Nm. The device can be easily and quickly mounted from the rear of the device. A panel thickness of 1 mm to 6 mm (0.039" to 0.236") is permitted for proper mounting. 1. Cut the mounting cutout in the housing for the device size to be installed. 2. Push the device through the mounting cutout from the front. B A Figure 2-1 3. 4. 5. 12 PHOENIX CONTACT C Mounting the device using a mounting bracket Fix the mounting brackets in the recesses provided (A). Pull the mounting brackets down until the snap into place (B). Secure the device using the threaded pins (C). 108594_en_04 Installation and Commissioning Front Panel Dimensions 2.2.1.1 7" Display (resistive) 147 2.2.1 203 Figure 2-2 108594_en_04 Front panel (dimensions in mm) PHOENIX CONTACT 13 WP 4000 7" Display (PCAP) 146,2 2.2.1.2 185,5 Figure 2-3 14 PHOENIX CONTACT Front panel (dimensions in mm) 108594_en_04 Installation and Commissioning 10.1" Display (PCAP) 199,3 2.2.1.3 262,7 Figure 2-4 108594_en_04 Front panel (dimensions in mm) PHOENIX CONTACT 15 WP 4000 12.1" Display (PCAP) 229 2.2.1.4 302 Figure 2-5 16 PHOENIX CONTACT Front panel (dimensions in mm) 108594_en_04 Installation and Commissioning 15.6" Display (PCAP) 278 2.2.1.5 436 Figure 2-6 108594_en_04 Front panel (dimensions in mm) PHOENIX CONTACT 17 WP 4000 18.5" Display (PCAP) 329 2.2.1.6 485 Figure 2-7 18 PHOENIX CONTACT Front panel (dimensions in mm) 108594_en_04 Installation and Commissioning 2.2.2 Mounting Cutout 2.2.2.1 7" Display (resistive) 147 139 ±0,5 A B 195 ±0,5 203 Figure 2-8 A B 108594_en_04 Mounting cutout (dimensions in mm) Mounting Cutout Front Panel PHOENIX CONTACT 19 WP 4000 2.2.2.2 7" Display (PCAP) 136 146,2 A B 175 185,5 Figure 2-9 A B 20 PHOENIX CONTACT Mounting cutout (dimensions in mm) Mounting Cutout Front Panel 108594_en_04 Installation and Commissioning 2.2.2.3 10.1" Display (PCAP) 199,3 189 A B 252 262,7 Figure 2-10 A B 108594_en_04 Mounting cutout (dimensions in mm) Mounting Cutout Front Panel PHOENIX CONTACT 21 WP 4000 2.2.2.4 12.1" Display (PCAP) 219 229 A B 292 302 Figure 2-11 A B 22 PHOENIX CONTACT Mounting cutout (dimensions in mm) Mounting Cutout Front Panel 108594_en_04 Installation and Commissioning 2.2.2.5 15.6" Display (PCAP) 278 260 ±0,5 A B 425 ±0,5 436 Figure 2-12 A B 108594_en_04 Mounting cutout (dimensions in mm) Mounting Cutout Front Panel PHOENIX CONTACT 23 WP 4000 2.2.2.6 18.5" Display (PCAP) 329 311 ±0,5 A B 475 ±0,5 485 Figure 2-13 A B 24 PHOENIX CONTACT Mounting cutout (dimensions in mm) Mounting Cutout Front Panel 108594_en_04 Installation and Commissioning 2.2.3 Side View, Mounting Depth 2.2.3.1 7" Display (resistive) 43 1 2 3 4 5 Figure 2-14 1 2 3 4 5 108594_en_04 Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel PHOENIX CONTACT 25 WP 4000 2.2.3.2 7" Display (PCAP) 45 1 2 3 4 5 Figure 2-15 1 2 3 4 5 26 PHOENIX CONTACT Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 108594_en_04 Installation and Commissioning 2.2.3.3 10.1" Display (PCAP) 45 1 2 3 4 5 Figure 2-16 1 2 3 4 5 108594_en_04 Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel PHOENIX CONTACT 27 WP 4000 2.2.3.4 12.1" Display (PCAP) 45 1 2 3 4 5 Figure 2-17 1 2 3 4 5 28 PHOENIX CONTACT Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 108594_en_04 Installation and Commissioning 2.2.3.5 15.6" Display (PCAP) 53 1 2 3 4 5 Figure 2-18 1 2 3 4 5 108594_en_04 Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel PHOENIX CONTACT 29 WP 4000 2.2.3.6 18.5" Display (PCAP) 53 1 2 3 4 5 Figure 2-19 1 2 3 4 5 30 PHOENIX CONTACT Side view, mounting depth (dimensions in mm) Mounting Bracket Threaded Pin Mounting Surface Thickness 1 mm to 6 mm Circumferential Seal Front Panel 108594_en_04 Installation and Commissioning 2.3 Connecting the Device 2.3.1 Supply Voltage The supply voltage is supplied via pin strip X1. A suitable socket strip is supplied. Refer to the technical data for the permissible supply voltage of the operating device. NOTICE: Damage The operating device has to be supplied by a power source, which meets the requirements for SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1. NOTICE: Damage For UL 61010, an 4 A (or smaller) fuse, either standard or electronic, or circuit breaker must be installed between the 24 V DC external power supply and the operating device. The fuse / circuit breaker must be rated at 30 V DC and be a UL listed component. The device has reverse polarity protection. In case of wrong polarity, the device will not operate. Connector in the operating device: 3 pin pin strip Table 2-1 Pin Pin assignment supply voltage Designation 1 Function Functional earth ground (FE) 2 0V Supply voltage 0 V (GND) 3  24 V Supply voltage  24 V DANGER: Hazardous voltages Hazardous voltages can exist inside electrical installations that can pose a danger to humans. Coming in contact with live parts may result in electric shock! NOTICE: Damage Cables with finely stranded copper conductors with a minimum cross-section of 0.75 mm² (18 AWG) and a maximum cross-section of 2.5 mm² (14 AWG) must be used for the supply voltage. You must adhere to the following torques at the connector: Screw connection of terminal blocks: 0.22 Nm (minimal) to 0.25 Nm (maximum) Screw flange: 0.3 Nm (maximum) Use the following procedure to connect the device to the supply voltage: 1. Strip approx. 30 mm (1.181") off the outer cable sheath and approx. 5 mm (0.197") off the wires. Figure 2-20 108594_en_04 Preparing the cable PHOENIX CONTACT 31 WP 4000 2. 3. 4. Fit the wires with wire end ferrules and connect the wires to the socket strip. Plug the socket strip onto pin strip X1. Secure the socket strip in place with a screw-type locking to prevent it from slipping out. 2.3.2 Grounding The grounding is performed with a slip-on sleeve (noiseless ground / functional earth ground). NOTICE: Damage A separate copper conductor must always be provided for the grounding. The conductor must have a minimum cross-section of 1.5 mm² (16 AWG) and must be kept as short as possible. 1. 2. 3. Strip approx. 5 mm (0.197") off the wires. Fit the stripped wires with a slip-on sleeve. Plug the slip-on sleeve on the flat tab. Figure 2-21 32 PHOENIX CONTACT Noiseless ground 108594_en_04 Installation and Commissioning 2.4 Switching On When switching on the operating system loads. The interface for microSDHC cards is available for applications and other data. Please also pay attention to the further information in the user manual of your software option at phoenixcontact.net/products. 2.5 Identification The operating device can be identified using the nameplate on the rear of the device. Ord. No. 1065546 Type: WP 4000 1 3 5 2 4 1067721-00 1065546/P29/R34/M76/O00/D31 MAC 00-AA-00-00-00-00 Un: 6 SNR: 201800000000 15 PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8, 32825 Blomberg, Germany Figure 2-22 1 2 3 4 5 6 24 V In: 0.4 A Nameplate (example) Article Number, Device Type Version Software (at time of delivery) Orderkey MAC Address(es) Voltage and Current Serial Number 2.5.1 Orderkey The configuration of the operating device can be read from the options in the orderkey on the nameplate. Table 2-2 108594_en_04 Orderkey Key Option Configuration D31 Display 7" LCD projected capacitive D36 Display 7" LCD resistive D35 Display 10,1" LCD projected capacitive D33 Display 12,1" LCD projected capacitive D28 Display 15.6" LCD projected capacitive D29 Display 18.5" LCD projected capacitive PHOENIX CONTACT 33 WP 4000 Table 2-2 34 PHOENIX CONTACT Orderkey Key Option Configuration P29 Processor ARM Cortex-A53, 4x 1.2 GHz P31 Processor ARM Cortex-A53, 4x 1.2 GHz TPM R34 Main memory 1 GB LPDDR3 M76 Master storage 8 GB eMMC Flash O00 Options No options 108594_en_04 Control and Display Elements 3 Control and Display Elements 3.1 Touchscreen The device is equipped with a touch screen. You operate the device using this touch screen. Note the following for devices equipped with a resistive 4-wire touch screen: NOTICE: Damage Pointed or sharp objects, such as pens or fingernails, can lead to irreparable damages of the touch screen. Exclusively therefore use the fingertips or the aids indicated in the technical data for the operation. 3.2 Display DANGER: Toxic If the display is damaged, avoid touching, swallowing or breathing in the liquids or gases which may leak out! DANGER: Corrosive If the display is damaged, avoid touching, swallowing or breathing in the liquids or gases which may leak out! Pixel failures, which can occur with TFT displays, are due to production and no complaint reason! The operating device is equipped with different displays (see technical data) depending on variant. 108594_en_04 PHOENIX CONTACT 35 WP 4000 3.3 Status LEDs Next to the slot for the microSD / microSDHC memory card there are status LEDs. 1 2 Figure 3-1 Position of the status LEDs The status LEDs have the following functions: Table 3-1 Status LEDs LED Color State Designation Function 1 Green Flashing Heartbeat The bootloader and the image has been started Off 2 Green On Off 36 PHOENIX CONTACT The operating device could not be started properly Power Supply voltage available Supply voltage not available 108594_en_04 Interfaces of the Device 4 Interfaces of the Device 4.1 Standard Interfaces 1 Figure 4-1 1 2 3 4 5 6 7 108594_en_04 2 3 4 5 6 7 Rear view Ethernet Female Connector X5 (Ethernet) Female Connector X9, X10 (USB Host - Type A) Status LED LD1 (Heartbeat) Status LED LD2 (Power) Slot for microSD- / microSDHC Memory Card Connector X1 (Supply Voltage) Flat Push-on Connection for Noiseless Grounding PHOENIX CONTACT 37 WP 4000 4.1.1 Ethernet (X5) A 10/100Base-T Ethernet interface is located at the operating device. 4.1.1.1 Pin Assignment Connector in the operating device: RJ45 female connector. Table 4-1 Pin Assignment of the Ethernet interface Designation Function 1 Tx+ Transmitted Data, Positive Polarity 2 Tx- Transmitted Data, Negative Polarity 3 Rx+ Received Data, Positive Polarity 4 n.c. Not Connected 5 n.c. Not Connected 6 Rx- Received Data, Negative Polarity 7 n.c. Not Connected 8 n.c. Not Connected 4.1.1.2 Cable NOTICE Use a twisted pair cable of category 5 (CAT 5). The maximum cable length is 100 m (328.084 feet). See the IEEE 802.3 standard for further information. 38 PHOENIX CONTACT 108594_en_04 Interfaces of the Device 4.1.1.3 Diagnostics Ethernet diagnostics LEDs are located at the operating device. Figure 4-2 Position of the ethernet diagnostics LEDs Table 4-2 Ethernet diagnostics LEDs LED Color State Designation Function 1 Green On ACT/LNK Connected Flashing 2 Yellow On Off 4.1.2 Sending / receiving ethernet data telegram SPD 10/100 Operation in 100 MBit/s mode Operation in 10 MBit/s mode or disconnected USB (X9, X10) Two host interfaces are available on the operating device. NOTICE: Using hardware not suitable for industrial use (for example keyboard, mouse, memory card) in industrial environments may decrease safety of operation. This includes hardware intended for home and office use. 4.1.2.1 Cable For the specification of a suitable cable, please refer to the „Universal Serial Bus Specification“. NOTICE: Use industrial-suited USB cables with a length of maximally 2.5 m (8.202 feet). 108594_en_04 PHOENIX CONTACT 39 WP 4000 4.1.3 Memory Card At the underside of the operating device you can plug in an microSD / microSDHC card. NOTICE: Using hardware not suitable for industrial use (for example keyboard, mouse, memory card) in industrial environments may decrease safety of operation. This includes hardware intended for home and office use. 4.1.3.1 Inserting the memory card When you insert the memory card, make sure the front side (side with contacts is below) of the memory card is visible. Insert the memory card until it snaps into place. Figure 4-3 4.1.3.2 Inserting the memory card Ejecting the memory card To remove, push the memory card into the operating device until it clicks. The memory card bounces when released automatically out of the operating device. Now you can remove the memory card. 40 PHOENIX CONTACT 108594_en_04 Maintenance and Servicing 5 Maintenance and Servicing 5.1 Front Panel Use a damp cloth to remove any dirt from the front panel. You also can use Isopropanol for stronger pollutions. 5.2 Fuse NOTICE: Damage The semiconductor fuse cannot be replaced! A semiconductor fuse is used to protect the device. Once the fuse has been tripped, the device must be disconnected from the supply voltage to allow the semiconductor fuse to regenerate. At an ambient temperature of 20 °C (68 °F), the regeneration takes approximately 20 seconds. The higher the ambient temperature, the longer the regeneration takes. 108594_en_04 PHOENIX CONTACT 41 WP 4000 42 PHOENIX CONTACT 108594_en_04 Technical Data 6 Technical Data 6.1 General Ethernet X5 Ethernet 10/100Base-T USB Corresponds to the „Universal serial bus specification Rev. 2.0“ X9, X10 Host Min.: 1.5 Mbit/s Max.: 12 Mbit/s Max. output current 100 mA per output Beeper Sound pressure level At most 85 db at a distance of 10 (3.937“) cm without shielding. The sound pressure level of the mounted operating device is dependent on the shielding at the mounting place. Central Processing Unit Central processing unit ARM Cortex™-A53 Clock frequency 1,2 GHz quad-core Other features Real-time clock (typical deviation is approx. 2 minutes per month) Real-time Clock The real-time clock is buffered with a capacitor. The capacitor reaches its maximum capacity after approximately 30 minutes of continuous charging. After a maximum charge, the real-time clock can be buffered approximately 10 days. Memory RAM 1 GByte LPDDR3 Mass storage 8 GByte eMMC microSD/microSDHC interface 2 GByte / 32 GByte maximum Connection System Male connector strip Phoenix MINI-COMBICON, 3 pin (Art.-No. 1847068) RJ45 male connector USB male connector type A 108594_en_04 PHOENIX CONTACT 43 WP 4000 Standards and Guidelines Interference immunity EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-6-2 Emitted interference EN 55011 limit value class A EN 55032 limit value class A EN 61000-6-4 Equipment requirements EN 61131-2 Storage and transportation EN 61131-2 Power supply EN 61131-2 Electromagnetic compatibility 2014/30/EU Degrees of protection EN 60529 Impact load, shocks EN 60068-2-27 Sinusoidal vibrations EN 60068-2-6 NOTICE: Radio Interference Operation of this device may cause radio interference in residential areas. 44 PHOENIX CONTACT 108594_en_04 Technical Data 6.2 7" Display (resistive) Touch Screen Type Analog resistive, 4 wire technology Activation force 15 g (Standard) With R8 HS60 silicon rubber Durability No damages or malfunctions after 3 million keystrokes as the following: Keystroke element: R8, HS40 silicon rubber Keystroke load: 150 g Keystroke frequency: 3 Hz Display Size (diagonal) in cm (inch) 17.78 (7) Type TFT (color) Resolution (pixels) 800 x 480 Colors 262144 Viewing angle (left / right / up / down) in ° 70 / 70 / 65 / 65 Half-life backlighting 40,000 h Brightness in cd/m2 350 Display area (H x W) in mm (Inch) 91.4 x 152.4 (3.598 x 6.0) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 25 °C to + 70 °C (- 13°F to + 158 °F) Relative air humidity for operation and storage 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption (typical at 24 V) 0.4 A Connected load 9.6 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated 108594_en_04 PHOENIX CONTACT 45 WP 4000 Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 147 x 203 x 5 (5.787 x 7.992 x 0.197) Seal Circumferential rubber seal on the rear Mounting cutout (H x W) in mm (Inch) 139 x 195 (5.7472 x 7.677) Mounting brackets 6 Mounting depth in mm (Inch) About 43 mm (1.692) Degree of protection Front: IP65 / NEMA Enclosure Type 1 (indoor use only) Rear: IP20 Total weight About 750 g Approvals CE approval CE UL approval UL / cUL 46 PHOENIX CONTACT 108594_en_04 Technical Data 6.3 7" Display (PCAP) Touch Screen Type Projected capacitive Operation With the finger Display Size (diagonal) in cm (inch) 17.78 (7) Type TFT (color) Resolution (pixels) 1280 x 800 Colors 16.77 million Viewing angle (left / right / up / down) in ° 85 / 85 / 85 / 85 Half-life backlighting 50,000 h Brightness in cd/m2 500 Display area (H x W) in mm (Inch) 91.4 x 152.4 (3.598 x 6.0) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 20 °C to + 60 °C (- 4 °F to 140 °F) Relative air humidity for operation and storage Front: 5 % to 95 %, no condensation Rear: 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption (typical at 24 V) 0.4 A Connected load 9.6 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 146.2 x 185.5 x 6 (5.755 x 7.303 x 0.236) Seal Flat gasket on the rear Mounting cutout (H x W) in mm (Inch) 136 x 175 (5.354 x 6.889) 108594_en_04 PHOENIX CONTACT 47 WP 4000 Front Panel and Enclosure Mounting brackets 6 Mounting depth in mm (Inch) About 45 (1.771) Degree of protection Front: IP65 / NEMA Enclosure Type 4 (indoor use only) Rear: IP20 Total weight About 760 g Approvals CE approval CE UL approval UL / cUL 48 PHOENIX CONTACT 108594_en_04 Technical Data 6.4 10.1" Display (PCAP) Touch Screen Type Projected capacitive Operation With the finger Display Size (diagonal) in cm (inch) 25.65 (10.1) Type TFT (color) Resolution (pixels) 1280 x 800 Colors 16.77 million Viewing angle (left / right / up / down) in ° 85 / 85 / 85 / 85 Half-life backlighting 50,000 h Brightness in cd/m2 850 Display area (H x W) in mm (Inch) 217 x 136 (8.543 x 5.354) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 20 °C to + 60 °C (- 4 °F to 140 °F) Relative air humidity for operation and storage Front: 5 % to 95 %, no condensation Rear: 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption (typical at 24 V) 0.6 A Connected load 14.4 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 199.3 x 262.7 x 6 (7.846 x 10.342 x 0.236) Seal Flat gasket on the rear Mounting cutout (H x W) in mm (Inch) 189 x 252 (7.44 x 9.921) 108594_en_04 PHOENIX CONTACT 49 WP 4000 Front Panel and Enclosure Mounting brackets 6 Mounting depth in mm (Inch) About 45 (1.771) Degree of protection Front: IP65 / NEMA Enclosure Type 4 (indoor use only) Rear: IP20 Total weight About 1270 g Approvals CE approval CE UL approval UL / cUL 50 PHOENIX CONTACT 108594_en_04 Technical Data 6.5 12.1" Display (PCAP) Touch Screen Type Projected capacitive Operation With the finger Display Size (diagonal) in cm (inch) 30.73 (12.1) Type TFT (color) Resolution (pixels) 1280 x 800 Colors 16.77 million Viewing angle (left / right / up / down) in ° 85 / 85 / 85 / 85 Half-life backlighting 50,000 h Brightness in cd/m2 380 Display area (H x W) in mm (Inch) 163.2 x 261.1 (6.425 x 10.28) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 20 °C to + 60 °C (- 4 °F to 140 °F) Relative air humidity for operation and storage Front: 5 % to 95 %, no condensation Rear: 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption (typical at 24 V) 0.7 A Connected load 16.8 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 229 x 302 x 6 (9.015 x 11.889 x 0.236) Seal Flat gasket on the rear Mounting cutout (H x W) in mm (Inch) 219 x 292 (8.622 x 11.496) 108594_en_04 PHOENIX CONTACT 51 WP 4000 Front Panel and Enclosure Mounting brackets 8 Mounting depth in mm (Inch) About 45 (1.771) Degree of protection Front: IP65 / NEMA Enclosure Type 4 (indoor use only) Rear: IP20 Total weight About 1650 g Approvals CE approval CE UL approval UL / cUL 52 PHOENIX CONTACT 108594_en_04 Technical Data 6.6 15.6" Display (PCAP) Touch Screen Type Projected capacitive Operation With the finger Display Size (diagonal) in cm (inch) 39.6 (15.6) Type TFT (color) Resolution (pixels) 1366 x 768 Colors 16.77 million Viewing angle (left / right / up / down) in ° 80 / 80 / 80 / 80 Half-life backlighting 70.000 h Brightness in cd/m2 320 Display area (H x W) in mm (Inch) 194 x 344 (7.637 x 13.543) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 25 °C bis + 70 °C (- 13°F to + 158 °F) Relative air humidity for operation and storage Front: 5 % to 95 %, no condensation Rear: 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption (typical at 24 V) 1A Connected load 24 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 278 x 436 x 6 (10.944 x 17.165 x 0.236) Seal Flat gasket on the rear Mounting cutout (H x W) in mm (Inch) 260 x 425 (10.236 x 16.732) 108594_en_04 PHOENIX CONTACT 53 WP 4000 Front Panel and Enclosure Mounting brackets 12 Mounting depth in mm (Inch) About 53 (2.086) Degree of protection Front: IP65 / NEMA Enclosure Type 1 (indoor use only) Rear: IP20 Total weight About 4000 g Approvals CE approval CE UL approval UL / cUL 54 PHOENIX CONTACT 108594_en_04 Technical Data 6.7 18.5" Display (PCAP) Touch Screen Type Projected capacitive Operation With the finger Display Size (diagonal) in cm (inch) 47 (18.5) Type TFT (color) Resolution (pixels) 1366 x 768 Colors 16.77 million Viewing angle (left / right / up / down) in ° 85 / 85 / 80 / 80 Half-life backlighting 50,000 h Brightness in cd/m2 240 Display area (H x W) in mm (Inch) 230 x 410 (9.055 x 16.141) Environmental Conditions Temperature during operation 0 °C to 50 °C (32 °F to 122 °F) - (with order key option P29 / P31) Temperature during storage, transport - 20 °C to + 60 °C (- 4 °F to 140 °F) Relative air humidity for operation and storage Front: 5 % to 95 %, no condensation Rear: 20 % to 85 %, no condensation Application area Degree of pollution 2, overvoltage category II No direct solar radiation Electrical Data Supply voltage 24 V DC (SELV / Limited energy circuit in accordance with EN 61010-1 / IEC 61010-1 or Class 2 in accordance with UL 1310 or Limited Power Source (LPS) in accordance with EN 60950-1 / IEC 60950-1) Residual ripple 10 % maximum Minimum voltage 18 V Maximum voltage 30 V Power consumption, typical at 24 V (standard / field bus) 1.2 A Connected load (standard / field bus) 28.8 W Fuse Semiconductor fuse, self-resetting Protection against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet, galvanized Front panel material Aluminium, brushed, anodized natural finish Front panel (H x W x D) in mm (Inch) 329 x 485 x 8 (12.952 x 19.094 x 0.314) 108594_en_04 PHOENIX CONTACT 55 WP 4000 Front Panel and Enclosure Seal Flat gasket on the rear Mounting cutout (H x W) in mm (Inch) 311 x 475 (12.244 x 18.7) Mounting brackets 12 Mounting depth in mm (Inch) - (standard / field bus) About 53 (2.086) Degree of protection Front: IP65 / NEMA Enclosure Type 1 (indoor use only) Rear: IP20 Total weight About 5500 g Approvals CE approval CE UL approval UL / cUL 56 PHOENIX CONTACT 108594_en_04 A1 Index C Cable Ethernet................................................................. 38 USB....................................................................... 39 Connecting.................................................................. 31 D Diagnostics Ethernet................................................................. Dimensions Cutout.................................................................... Front panel ............................................................ Display ........................................................................ Mounting depth 10.1" Display (PCAP) ............................................ 12.1" Display (PCAP) ............................................ 15.6" Display (PCAP) ............................................ 18.5" Display (PCAP) ............................................ 7" Display (PCAP) ................................................. 7" Display (resistive).............................................. 27 28 29 30 26 25 N 39 Nameplate .................................................................. 33 19 13 35 P Pin assignment Ethernet................................................................. 38 F Front panel dimensions 10.1" Display (PCAP) ............................................ 12.1" Display (PCAP) ............................................ 15.6" Display (PCAP) ............................................ 18.5" Display (PCAP) ............................................ 7" Display (PCAP) ................................................. 7" Display (resistive).............................................. Fuse ............................................................................ R 15 16 17 18 14 13 41 I Identification................................................................ 33 Intended use ................................................................. 8 Interface Ethernet................................................................. 38 USB....................................................................... 39 M Maintenance ............................................................... Memory card ............................................................... Mounting ..................................................................... Mounting cutout 10.1" Display (PCAP) ............................................ 12.1" Display (PCAP) ............................................ 15.6" Display (PCAP) ............................................ 18.5" Display (PCAP) ............................................ 7" Display (PCAP) ................................................. 7" Display (resistive).............................................. 108594_en_04 41 40 12 21 22 23 24 20 19 Rear view Ethernet................................................................. 37 S Safety notes .................................................................. 7 Servicing ..................................................................... 41 Side view 10.1" Display (PCAP) ............................................ 27 12.1" Display (PCAP) ............................................ 28 15.6" Display (PCAP) ............................................ 29 18.5" Display (PCAP) ............................................ 30 7" Display (PCAP) ................................................. 26 7" Display (resistive).............................................. 25 Standards ................................................................... 44 Supply Voltage............................................................ 31 Switching on ............................................................... 33 Symbols ........................................................................ 7 T Target group ................................................................. 9 Technical data ............................................................ 43 10.1" Display (PCAP) ............................................ 49 12.1" Display (PCAP) ............................................ 51 15,6" Display (PCAP) ............................................ 53 18.5" Display (PCAP) ............................................ 55 7" Display (PCAP) ................................................. 47 7" Display (resistive).............................................. 45 PHOENIX CONTACT 57 WP 4000 Touchscreen ............................................................... 35 U Unpacking................................................................... 11 V Version........................................................................ 33 58 PHOENIX CONTACT 108594_en_04
1148693 价格&库存

很抱歉,暂时无法提供与“1148693”相匹配的价格&库存,您可以联系我们找货

免费人工找货