CHARX connect, Vehicle charging inlet, Locking actuator right, For charging electric vehicles (EV) with alternating
current (AC), For installation in electric vehicles (EV), AC type 2, IEC 62196-2, 32 A / 250 V (AC), length: 2
m, Locking actuator: 12 V, 4-position, M6, Generation 4, A protective cap is supplied as standard for the AC
contacts.
The figure shows a version of the
product
Product Description
Vehicle charging inlet for charging with alternating current (AC), compatible with type 2 AC vehicle charging connectors (EVSE), for installation in electric
vehicles for e-mobility (EV).
Your advantages
Uniform, space-saving dimensions and screw connection points for all Phoenix Contact AC vehicle charging inlets
Silver-plated surface of the power and signal contacts
Developed and produced in accordance with the IATF 16949 automotive standard and ISO 9001
Material data available in the IMDS (International Material Data System of the automotive industry)
Tested in accordance with selected tests of automotive standards LV124, LV214, LV215-2
Manual emergency release of the locking actuator
Integrated interlock during charging
Integrated temperature sensors for monitoring the temperature at the power contacts
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4063151461294
Custom tariff number
85444290
Country of origin
Germany
08/23/2021 Page 1 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Technical data
Product definition
Type
Locking actuator right
Application
For charging electric vehicles (EV) with alternating current (AC)
For installation in electric vehicles (EV)
Design
Generation 4
Standards/regulations
IEC 62196-2
Charging standard
AC type 2
Charging mode
Mode 2, 3
Note
A protective cap is supplied as standard for the AC contacts.
Note on the connection method
Crimp connection, cannot be disconnected
Dimensions
Height
90 mm
Width
90 mm
Depth
111.4 mm
Bore dimensions
73 mm x 73 mm, 73 mm x 73 mm
Conductor length
2 m (AC sheathed cable)
1 m (Locking actuator cables)
1 m (Temperature sensors cables)
1 m (Communications cables)
Ambient conditions
Ambient temperature (operation)
-40 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. altitude
4000 m (above sea level)
Degree of protection
IP55 (plugged in; when plugged in and ready to operate, the degree of
protection is only ensued if both plug-in components are original products
from Phoenix Contact or suitable standard-compliant products)
IP67 (Inner area of vehicle charging inlet)
Electrical properties
Charging power (nominal operation)
8 kW
Type of charging current
AC single-phase
Number of power contacts
3 (L1, N, PE)
Rated current of power contacts
32 A AC
Rated voltage for power contacts
250 V AC
Number of signal contacts
2 (CP, PP)
Rated current for signal contacts
2A
Rated voltage for signal contacts
30 V AC
08/23/2021 Page 2 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Technical data
Electrical properties
Type of signal transmission
Pulse width modulation with modulated Powerline communication
according to ISO/IEC 15118 / DIN SPEC 70121
Note on the connection method
Crimp connection, cannot be disconnected
Insulation resistance of neighboring contacts
> 200 MΩ
Resistor coding
4.7 kΩ (between PE and PP)
Temperature monitoring
AC contacts: PTC chain (DIN˽EN˽60738-1)
Mechanical properties
Insertion/withdrawal cycles
> 10000
Insertion force
< 75 N
Withdrawal force
< 75 N
Mounting
Restrictions to mounting position
Only 0 to 90 degree frontal inclination possible, see figure
Mounting position of the locking actuator
Right-side
Mounting hole diameter
6.70 mm (ø)
Required mounting screws
M6
Screws included in the scope of delivery
none
Design
Design line
Generation 4
Housing color
black
Customer variations
On request
Material
Material
Plastic
Flammability rating
V0
Material surface of contacts
Ag
Locking
Locking type
Locking in the inserted state with a locking mechanism
AC cable
Cable structure
3 x 6 mm²
External cable diameter
13.8 mm ±0.3 mm
Cable resistance
≤ 3.2 Ω/km
Outer sheath, material
Silicone
External sheath, color
orange
Minimum bending radius
3 x D
Cable weight
approx. 385 kg/km
Locking actuator cable
08/23/2021 Page 3 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Technical data
Locking actuator cable
Cable structure
4 x 0.5 mm²
External cable diameter
1.6 mm -0.2 mm
Cable resistance
≤ 37.1 Ω/km
Outer sheath, material
PVC
Single wire, color
BU/RD, BU/GN, BU/YE, BU/BN
Minimum bending radius
15 mm
Cable weight
7 kg/km
Temperature sensor cable
Cable structure
2 x 0.5 mm²
External cable diameter
1.6 mm -0.2 mm
Cable resistance
≤ 37.1 Ω/km
Outer sheath, material
PVC
Single wire, color
brown, gray
Minimum bending radius
15 mm
Cable weight
7 kg/km
Cable communication
Cable structure
0.5 mm² + 0.5 mm²
External cable diameter
1.6 mm -0.2 mm
Cable resistance
≤ 37.1 Ω/km
Outer sheath, material
PVC
Single wire, color
black PP/CS
white CP
Minimum bending radius
15 mm
Cable weight
7 kg/km
Locking actuator
Number of positions of theconnectors
4
Operating voltage
12 V (Typical power supply at the motor)
Possible power supply range at the motor
9 V ... 16 V
Maximum voltage for locking detection
12 V
Typical motor current for locking
0.25 A
Reverse current of the motor
max. 1.5 A
Max. dwell time with reverse current
1s
Recommended adaptation time
600 ms
Pause time after entry or exit path
3s
Service life insertion cycles
> 10000 load cycles
Ambient temperature (operation)
-40 °C ... 80 °C
08/23/2021 Page 4 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Technical data
Locking actuator
Cable length
1m
Cable structure
4 x 0.5 mm²
Lock recognition
available
Mechanical emergency release
available
Temperature monitoring, AC contacts
Type of sensor
PTC chain
Standards/regulations
DIN˽EN 60738-1
Recommended measured current
≤ 1 mA (Umax= 16 V DC)
Tolerance at the sensor with the recommended measured current
±5K
Temperature range
-40 °C ... 130 °C
Drawings
M
[V]
Diagram
Schematic diagram
24
+ BU/RD 0,5 mm²
12
"
M
0
-12
R2
10k
R1 BU/GN
0,5 mm²
1k
BU/YE 0,5 mm²
- BU/BN 0,5 mm²
-24
0
200
400
600
800 1000 1200 1400 1600
t [ms]
Block diagram of the locking actuator
RL
!
RU
0
200
400
600
800 1000 1200 1400 1600
t [ms]
Locking states of the locking actuator
08/23/2021 Page 5 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Connection diagram
Dimensional drawing
112,8
PP
111,4
□90
CP
101,3
□73
6,85
10
60
L3
Ø6,7
Pin assignment of Vehicle Inlet
11,8
L2
N
95,1
L1
Ø83
23
PE
Ø11
Dimensional drawing
T [°C]
Schematic diagram
Charging
Shutdown
shutdown threshold
RPTC [Ω]
Temperature sensor technology resistance range at AC contacts
08/23/2021 Page 6 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Connection diagram
CP
PP
N
PE
L1
L2
L3
N
L3
L2
L1
PP
PP
L2
N
L3
CP
PE
CP
PE
L1
PP
L2
L1
L3
PE
N
CP
Installation positions
08/23/2021 Page 7 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Connection diagram
AC
Terminology definition
08/23/2021 Page 8 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Functional drawing
AC
[I]
AC
[II]
AC
[III]
AC
[IV]
[V]
Operating instructions
AC
08/23/2021 Page 9 / 11
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Schematic diagram
RL
RU
X1
X2
X3
X4
X (mm)
CHARX T2HCI12...: RU = 1 kΩ
RL = 11 kΩ
RU = 1 kΩ
CHARX T2HCI24...: RU = ∞ kΩ
RL = 0 kΩ
RU = ∞ kΩ
08/23/2021 Page 10 / 11
Detection for Vehicle Connector
https://www.phoenixcontact.com/us/products/1271830
Vehicle charging inlet - CHARX T2HCI12-1AC32-2,0M2 - 1271830
Classifications
eCl@ss
eCl@ss 10.0.1
27144706
eCl@ss 11.0
27144706
ETIM
ETIM 7.0
EC002898
Phoenix Contact 2021 © - all rights reserved
http://www.phoenixcontact.com
08/23/2021 Page 11 / 11