Basicline 2 PPC 1200 industrial PC
User manual
UM EN BL2 PPC 1200
User manual
Basicline 2 PPC 1200 industrial PC
2021-02-10
UM EN BL2 PPC 1200, Revision C
This user manual is valid for:
Order No.
1274012
1274014
4031_en_C
Designation
BL2 PPC7 1201-4/64-W10
BL2 PPC10 1201-4/128-W10
PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
phoenixcontact.com
Table of contents
Table of contents
1
2
3
For your safety ............................................................................................................................ 5
1.1
Labeling of warning notes...................................................................................... 5
1.2
Qualification of users ............................................................................................. 5
1.3
Field of application of the product.......................................................................... 5
1.3.1
Intended use .......................................................................................... 5
1.3.2
Product changes .................................................................................... 6
Overview and ordering data........................................................................................................ 7
2.1
Description ............................................................................................................ 7
2.2
Ordering data ........................................................................................................ 7
Installation .................................................................................................................................. 9
3.1
Mounting ............................................................................................................... 9
3.2
Interfaces............................................................................................................. 11
3.2.1
Power connection ................................................................................ 12
3.2.2
Serial communication .......................................................................... 13
3.3
Antenna ............................................................................................................... 14
A
Technical appendix...................................................................................................................15
B
Appendixes...............................................................................................................................19
A1
4031_en_C
Technical data .................................................................................................... 15
B1
List of figures ...................................................................................................... 19
B2
List of tables ....................................................................................................... 21
PHOENIX CONTACT
3/24
BL2 PPC 1201-4/…
4/24
PHOENIX CONTACT
4031_en_C
For your safety
1
For your safety
Read this user manual carefully and keep it for future reference.
1.1
Labeling of warning notes
This symbol indicates hazards that could lead to personal injury.
There are three signal words indicating the severity of a potential injury.
DANGER
Indicates a hazard with a high risk level. If this hazardous situation is not
avoided, it will result in death or serious injury.
WARNING
Indicates a hazard with a medium risk level. If this hazardous situation is not
avoided, it could result in death or serious injury.
CAUTION
Indicates a hazard with a low risk level. If this hazardous situation is not avoided,
it could result in minor or moderate injury.
This symbol together with the NOTE signal word alerts the reader to a situation
which may cause damage or malfunction to the device, hardware/software, or
surrounding property.
Here you will find additional information or detailed sources of information.
1.2
Qualification of users
The use of products described in this user manual is oriented exclusively to:
– Qualified electricians or persons instructed by them. The users must be familiar with the
relevant safety concepts of automation technology as well as applicable standards and
other regulations.
– Qualified application programmers and software engineers. The users must be familiar
with the relevant safety concepts of automation technology as well as applicable standards and other regulations.
1.3
1.3.1
Field of application of the product
Intended use
The products described in this document are designed for use in manufacturing and
industrial environments. They are tested to ITE levels.
The products are built according to the latest safety requirements. However, dangerous
situations or damage to the products or other property can arise from misuse of this device.
4031_en_C
PHOENIX CONTACT
5/24
BL2 PPC 1201-4/…
The products fulfill the requirements of the EMC directives and harmonized European
standards Any modifications to the systems can influence the EMC behavior.
The device contains valuable recyclable materials, which should be utilized. The
electronic circuit board is fitted with a lithium battery.
Dispose of the device separately from other waste, i.e., via an appropriate collection site.
Operating display panel at full brightness for long duty cycles and/or at higher ambient
temperature may short lifespan of the display.
Dim panel when not in use to extend the life of the display.
Radio interference
These products are Class A items of equipment (EN 55024 and EN 55032). When using the
equipment in residential areas, it may cause radio interference. In this case, the operator is
obligated to implement appropriate measures.
1.3.2
Product changes
Changes or modifications to hardware and software of the device are not permitted.
Incorrect operation or modifications to the device can endanger your safety or damage the
device. Do not repair the device yourself. If the device is defective, please contact
Phoenix Contact.
6/24
PHOENIX CONTACT
4031_en_C
Overview and ordering data
2
Overview and ordering data
2.1
Description
The BL2 PPC 1201-4/… IPC is a configurable panel PC (PPC) that utilizes the Intel®
processors chosen for their balance of processing power, graphic performance, and energy
efficiency. The robust design and I/O capability make the BL2 PPC 1201-4/… a product that
can be used in a wide variety of applications.
Features
–
–
–
–
–
–
–
Compact, rugged housing
Fanless design available
Two integrated 10/100/1000 Ethernet ports with independent MAC addresses
IP65 rating (front), IP20 rating (back)
Two UEFI-configurable RS-232/422/485 communication ports
Up to 4 GB RAM
USB 2.0 and 3.0 ports
2.2
Ordering data
Products
Description
Industrial panel PC, Intel® Celeron® processor N3350
1.10/2.40 GHz, 7-inch display, 4 GB of RAM, 64 GB mSATA
SSD, and Windows 10 IoT Enterprise LTSC 2019
Industrial panel PC, Intel® Celeron® processor N3350
1.10/2.40 GHz, 10-inch display, 4 GB of RAM,
128 GB mSATA SSD, and Windows 10 IoT Enterprise LTSC
2019
Accessories
Description
Visit phoenixcontact.net/products for available accessories
Replacement parts
Description
Connector, printed circuit board connector
4031_en_C
Type
BL2 PPC7 1201-4/64-W10
Order No.
1274012
Pcs./Pkt.
1
BL2 PPC10 1201-4/128W10
1274014
1
Type
Order No.
Pcs./Pkt.
Type
MC 1,5/ 2-STF-3,81
Order No.
1827703
Pcs./Pkt.
1
PHOENIX CONTACT
7/24
BL2 PPC 1201-4/…
8/24
PHOENIX CONTACT
4031_en_C
Installation
3
Installation
NOTE:
Exceeding the system temperature limits can result in performance degradation of any or
all components.
Install the BL2 PPC 1201-4/… with adequate clearance around the heat sink and provide
a minimum of 0.5 m/s air flow so that ambient air temperatures do not exceed the
operation limits. Insert cooling fan(s) in the enclosure, if necessary.
Connectors and switches must be accessible.
When installing the BL2 PPC 1201-4/… in a enclosure, follow these general rules:
– Verify clearances within the cabinet. Typically, leave at least 5 cm (2 in.) on each side
with 13 cm (5 in.) on the connector side.
– Drill all holes and make all cuts before beginning installation. Be sure to protect already
installed components from shavings during this procedure.
– Supporting panels must be at least 1.9 mm (14 ga.) to provide proper support.
– Make sure that there is adequate space around the heat sink to provide sufficient
cooling.
3.1
1.
Mounting
Cut a hole in the enclosure according to the dimensions for the selected display.
X
Y
Figure 3-1
Panel cutout dimensions
Table 3-1
Display cutout dimensions
Display size
7 in.
10 in.
4031_en_C
X (mm)
186
229
Y (mm)
124
155
PHOENIX CONTACT
9/24
BL2 PPC 1201-4/…
Remove the paper seal (1) from the sticky side of the gasket (2) and apply it to the back
side of the bezel (3).
U
S
B
2.0
2.
P
W
O
E
R
1
2
3
Figure 3-2
3.
4.
Gasket installation
Insert the BL2 PPC 1201-4/… through the opening.
Insert the screws (1) through the clamps (2).
1
2
3
Figure 3-3
5.
6.
7.
10/24
PHOENIX CONTACT
Panel-mounting clamps
From the rear of the enclosure, place a clamp in each slot (3) and slide away from the
enclosure panel.
Using an alternating pattern, turn each screw clockwise until the BL2 PPC 1201-4/… is
secured in the enclosure panel.
Torque each clamp screw to 0.88 Nm.
4031_en_C
Installation
3.2
Interfaces
3
1
2
USB2.0
POWER
9 8 7 6
9 8 7 6
5 4 3 2 1
5 4 3 2 1
LAN
LAN
5 4 3 2 1
9 8 7 6
COM 1
— +
DC-IN 9~30V
HDMI
USB3.0
1
2
3
4
8
7
6
Power switch
USB 2.0 port
Configurable RS-232/422/485 serial
ports
Power connector
Figure 3-4
5
6
7
8
5
4
HDMI port
RS-232 serial port
Ethernet RJ45 ports
USB 3.0 connectors
Connectors and ports (BL2 PPC10 1200 shown)
After mounting the BL2 PPC 1201-4/… in the enclosure, make any necessary cable
connections (see Figure 3-4)
The available connectors are:
– Ethernet (ETH): Two RJ45 connectors allow the computer to communicate on a
10/100/1000 Base-T Ethernet network.
– Serial (COM): Three D-SUB 9 serial ports are available for use. The default for all ports
is RS-232, IIRC. Two ports are configurable as either RS-232, RS-422, or RS-485.
– USB (USB): USB devices connect using Type A connectors. Two ports are USB 2.0
and one is USB 3.0.
USB 3.0 ports utilize a blue connector. USB 2.0 ports are black.
4031_en_C
PHOENIX CONTACT
11/24
BL2 PPC 1201-4/…
3.2.1
Power connection
A two-wire removable connector is provided for providing power to the BL2 PPC 1201-4/….
M1
CO
—
DC
-IN
+ 0V
3
9~
MI
HD
Figure 3-5
—
+
Power connector
Connect a power source to the included power connector. This connector supports wire
sizes from 0.2 to 2.5 mm² (24 to 12 AWG). Torque the wire-retaining screws in the
connector to 0.5 Nm (4.4 lbf-in.). Secure the connector to the BL2 PPC 1201-4/… chassis.
Table 3-2
Power connector
Pin No.
Description
+
24 V DC ±20%
–
0 V DC
NOTE:
To ensure safe operation, use safety extra-low voltage (SELV) according to DIN EN 61131
as supply voltage.
This device is protection class I item of equipment.
UEFI is set to boot on power, allowing the system to boot as soon as the power plug is
installed. This can be changed in the UEFI.
12/24
PHOENIX CONTACT
4031_en_C
Installation
3.2.2
Serial communication
Two D-SUB 9 connectors (see Figure 3-4) can be configured to communicate on the
RS-232, RS-422, or RS-485 physical layer.
The BL2 PPC 1201-4/… is capable of the following communication parameters:
Table 3-3
RS-232/422/485 communication settings
Data bits
RS-232
RS-422/485 Autotoggle RTS
RS-422/485 Manual RTS
Parity
Stop bits
None/Even/Odd
1/2
7/8
None/Even/Odd
7/8
None/Even/Odd
8
1/2
1/2
The table shows the capabilities of the IPC. Configuration of parameters to communicate
with a specific device is typically part of the software tool performing the communication.
The function of the pins in the D-SUB 9 connector varies with the different configuration
settings.
Table 3-4
D-SUB 9 pin
RS-232
RS-422
RS-485
2
RXD
TXD+
TXD+/RXD+
1
3
4
5
6
7
8
9
4031_en_C
D-SUB 9 pinout
DCD
TXD
DTR
GND
DSR
RTS
CTS
Ring indicator
TXD-
RXD+
RXDGND
–
–
–
–
TXD-/RXD–
–
GND
–
–
–
–
PHOENIX CONTACT
13/24
BL2 PPC 1201-4/…
3.3
Antenna
P
W
O
R
E
An optional factory-installed mini PCIe card is available to allow the BL2 PPC 1201-4/… to
be placed on a wireless network. Included with the installed card is an antenna (1) that
attaches to a connector on the side of the unit (2).
U
S
B
0
2.
1
3
2
Figure 3-6
Antenna installation
Since the BL2 PPC 1201-4/… is often installed within an enclosure, it may be advisable to
install the antenna on the exterior of the enclosure rather than directly to the IPC. To do this,
an appropriate length antenna cable (3) must be purchased separately.
The antenna or antenna threads onto the BL2 PPC 1201-4/…. For external antenna
mounting, route and secure the antenna cable appropriately within the enclosure.
NOTE:
Do not allow metal chips to fall within the enclosure when creating the hole for mounting
the antenna.
Installation of the miniPCI card for wireless communication voids the UL 61010 listing.
14/24
PHOENIX CONTACT
4031_en_C
Technical appendix
A Technical appendix
A1
Technical data
General data
Overall, dimensions (width x height x depth)*
BL2 PPC7 1201-4/64-W10
196 x 134 x 48 mm
BL2 PPC7 1201-4/64-W10
1.2 kg
BL2 PPC10 1201-4/128-W10
Ambient temperature (operation)†
Ambient temperature (storage/transport)
Permissible humidity (relative)
Weight
BL2 PPC10 1201-4/128-W10
Degree of protection
Mounting
LED indicators
*
Dimensions are overall, including bezel
†
With 0.5 m/s airflow
Electrical data
Power supply, nominal
Type of connection
Conductor size
Torque, wire clamping screw
Current and power data*
Current consumption @ 24 V, maximum†
266 x 184 x 48 mm
-5 … 50°C
-20 … 70°C
10% … 90%, non-condensing
2.9 kg
IP65
VESA 75, VESA 100, panel mount
24 V DC ±20%
Removable screw-type
0.2 … 2.5 mm² (24 … 12 AWG)
0.5 … 0.6 Nm
BL2 PPC7 1201-4/64-W10
1.07 A
BL2 PPC7 1201-4/64-W10
25.7 W
BL2 PPC10 1201-4/128-W10
Power, maximum @ 24 V, maximum†
BL2 PPC10 1201-4/128-W10
1.09 A
26.0 W
*
Does not include wireless mini PCIe card
†
Windows 10, SSD and M.2 drives, 8 GB RAM, loopback plugs in all COM and LAN ports, USB ports fully loaded, running Burn-in® tests
Operating systems
Operating system (configuration option)
Windows® 10 IoT Enterprise LTSB 2019
Data storage
Type (configurable option)
Number of bays
RAID support
Internal mSATA SSD
1
None
4031_en_C
PHOENIX CONTACT
15/24
BL2 PPC 1200
Main memory
RAM, maximum
Type
4 GB
DDR3L
Processor data
Processor
Clock speed
Intel Celeron N3350
1.10 GHz
Cache
Number of cores
Number of threads
Maximum TDP
Number of memory channels
2.40 GHz burst
2 MB
2
2
6W
2
Interfaces
USB
Serial connection
Super I/O chipset
Chipset
Video out
Graphic processor
Number of Ethernet connectors
Ethernet connection
LAN chipset
Number of mini PCIe slots*
Mini PCIe card size, maximum
1x Type A USB 2.0; 2x Type A USB 3.0
1x D-SUB 9 (male), UEFI selectable for RS-232/422/485
Nuvoton NCT6106D
Integrated
1x DP++
Intel HD Graphics 500
2
10/100/1000 Mbps
Intel Ethernet controller I211-AT
1
30.00 x 50.95 x 15.00 mm
*
16/24
This slot is not available if ordered with the wireless option
PHOENIX CONTACT
4031_en_C
Technical data
Radio module (configurable)
Connector type
Device interface
Frequency band
Antenna impedance
Frequency range
Mini PCIe
PCI Express v1.2
IEEE 802.11 a/b/g/n
50
2.4 GHz
2412 ... 2472 Hz
2.4 GHz
802.11b/g 1… 54 Mbps
5 GHz
Data transfer rate
5 GHz
Transmit power, typical
2.4 GHz (b)
2.4 GHz (g)
5 GHz (a)
Display – 7 in. (BL2 PPC7 1201-4/64-W10)
Display backlighting type
Screen size, diagonal
Screen size, horizontal x vertical
Resolution
Type
Brightness
Number of colors
Backlight life, minimum
Contrast ratio
View angle, horizontal/vertical (CR=10), typ.
Installation cutout dimensions (width x height)
4031_en_C
5180 ... 5825 Hz
802.11a 6 … 54 Mbps
802.11n 2.4/5 GHz MCS0/8 … 7/13
12.5 dBm (Channel 1)
14.5 dBm (Channel 2-10)
11.0 dBm (Channel 11)
13.5 dBm (Channel 1)
14.0 dBm (Channel 2-10, 54 Mbps)
11.5 dBm (Channel 11)
12.5 dBm (Channel 36-165, 6-48 Mbps)
12.0 dBm (Channel 36-165, 54 Mbps)
LED
178 mm
153.6 x 90 mm
1024 x 600
Capacitive touch screen
320 Cd/m²
16.2 million
20000 h
1000:1
140°/120
186 x 124 mm
PHOENIX CONTACT
17/24
BL2 PPC 1200
Display – 10 in. (BL2 PPC10 1201-4/128-W10)
Display backlighting type
Screen size, diagonal
Screen size, horizontal x vertical
Resolution
Type
Brightness
Number of colors
Backlight life, minimum
Contrast ratio
View angle, horizontal/vertical (CR=10), typ.
Installation cutout dimensions (width x height)
LED
256 mm
217 x 136 mm
1280 x 800
Capacitive touch screen
400 Cd/m²
265,000
25000 h
1300:1
170°/170°
229 x 155 mm
Mechanical tests
Shock test according to IEC 60068-2-27
Vibration resistance according to EN 60068-2-6
20g with 11 ms duration
3g, 5-500 Hz
Approvals
CE compliant
FCC Part 15 Class A
UL/cUL
UL 61010*
*
18/24
Installation of the miniPCI card for wireless communication voids the UL 61010 listing.
Use of the VESA mount (outside an enclosure) removes the UL 61010 listing
PHOENIX CONTACT
4031_en_C
Appendixes
B Appendixes
B1
List of figures
Section 3
4031_en_C
Figure 3-1:
Panel cutout dimensions ....................................................................... 9
Figure 3-2:
Gasket installation .............................................................................. 10
Figure 3-3:
Panel-mounting clamps ...................................................................... 10
Figure 3-4:
Connectors and ports (BL2 PPC10 1200 shown) ............................... 11
Figure 3-5:
Power connector ................................................................................. 12
Figure 3-6:
Antenna installation ............................................................................ 14
PHOENIX CONTACT
19/24
BL2 PPC 1200
20/24
PHOENIX CONTACT
4031_en_C
List of tables
B2
List of tables
Section 3
4031_en_C
Table 3-1:
Display cutout dimensions ..................................................................... 9
Table 3-2:
Power connector.................................................................................. 12
Table 3-3:
RS-232/422/485 communication settings ............................................ 13
Table 3-4:
D-SUB 9 pinout.................................................................................... 13
PHOENIX CONTACT
21/24
BL2 PPC 1200
22/24
PHOENIX CONTACT
4031_en_C
Please observe the following notes
General terms and conditions of use for technical documentation
Phoenix Contact reserves the right to alter, correct, and/or improve the technical
documentation and the products described in the technical documentation at its own
discretion and without giving prior notice, insofar as this is reasonable for the user. The
same applies to any technical changes that serve the purpose of technical progress.
The receipt of technical documentation (in particular user documentation) does not
constitute any further duty on the part of Phoenix Contact to furnish information on
modifications to products and/or technical documentation. You are responsible to verify the
suitability and intended use of the products in your specific application, in particular with
regard to observing the applicable standards and regulations. All information made
available in the technical data is supplied without any accompanying guarantee, whether
expressly mentioned, implied or tacitly assumed.
In general, the provisions of the current standard Terms and Conditions of Phoenix Contact
apply exclusively, in particular as concerns any warranty liability.
This manual, including all illustrations contained herein, is copyright protected. Any
changes to the contents or the publication of extracts of this document is prohibited.
Phoenix Contact reserves the right to register its own intellectual property rights for the
product identifications of Phoenix Contact products that are used here. Registration of such
intellectual property rights by third parties is prohibited.
Other product identifications may be afforded legal protection, even where they may not be
indicated as such.
PHOENIX CONTACT
23/24
24
Internet
How to contact us
Up-to-date information on Phoenix Contact products and our Terms and Conditions can be
found on the Internet at:
phoenixcontact.com
Make sure you always use the latest documentation.
It can be downloaded at:
phoenixcontact.net/products
Subsidiaries
If there are any problems that cannot be solved using the documentation, please contact
your Phoenix Contact subsidiary.
Subsidiary contact information is available at phoenixcontact.com.
Published by
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstraße 8
32825 Blomberg
GERMANY
PHOENIX CONTACT Development and Manufacturing, Inc.
586 Fulling Mill Road
Middletown, PA 17057
USA
Should you have any suggestions or recommendations for improvement of the contents and
layout of our manuals, please send your comments to:
tecdoc@phoenixcontact.com
24/24
PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
phoenixcontact.com