0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1274014

1274014

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    SBC 1 CORE 4GB/0GB RAM

  • 数据手册
  • 价格&库存
1274014 数据手册
Basicline 2 PPC 1200 industrial PC User manual UM EN BL2 PPC 1200 User manual Basicline 2 PPC 1200 industrial PC 2021-02-10 UM EN BL2 PPC 1200, Revision C This user manual is valid for: Order No. 1274012 1274014 4031_en_C Designation BL2 PPC7 1201-4/64-W10 BL2 PPC10 1201-4/128-W10 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com Table of contents Table of contents 1 2 3 For your safety ............................................................................................................................ 5 1.1 Labeling of warning notes...................................................................................... 5 1.2 Qualification of users ............................................................................................. 5 1.3 Field of application of the product.......................................................................... 5 1.3.1 Intended use .......................................................................................... 5 1.3.2 Product changes .................................................................................... 6 Overview and ordering data........................................................................................................ 7 2.1 Description ............................................................................................................ 7 2.2 Ordering data ........................................................................................................ 7 Installation .................................................................................................................................. 9 3.1 Mounting ............................................................................................................... 9 3.2 Interfaces............................................................................................................. 11 3.2.1 Power connection ................................................................................ 12 3.2.2 Serial communication .......................................................................... 13 3.3 Antenna ............................................................................................................... 14 A Technical appendix...................................................................................................................15 B Appendixes...............................................................................................................................19 A1 4031_en_C Technical data .................................................................................................... 15 B1 List of figures ...................................................................................................... 19 B2 List of tables ....................................................................................................... 21 PHOENIX CONTACT 3/24 BL2 PPC 1201-4/… 4/24 PHOENIX CONTACT 4031_en_C For your safety 1 For your safety Read this user manual carefully and keep it for future reference. 1.1 Labeling of warning notes This symbol indicates hazards that could lead to personal injury. There are three signal words indicating the severity of a potential injury. DANGER Indicates a hazard with a high risk level. If this hazardous situation is not avoided, it will result in death or serious injury. WARNING Indicates a hazard with a medium risk level. If this hazardous situation is not avoided, it could result in death or serious injury. CAUTION Indicates a hazard with a low risk level. If this hazardous situation is not avoided, it could result in minor or moderate injury. This symbol together with the NOTE signal word alerts the reader to a situation which may cause damage or malfunction to the device, hardware/software, or surrounding property. Here you will find additional information or detailed sources of information. 1.2 Qualification of users The use of products described in this user manual is oriented exclusively to: – Qualified electricians or persons instructed by them. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. – Qualified application programmers and software engineers. The users must be familiar with the relevant safety concepts of automation technology as well as applicable standards and other regulations. 1.3 1.3.1 Field of application of the product Intended use The products described in this document are designed for use in manufacturing and industrial environments. They are tested to ITE levels. The products are built according to the latest safety requirements. However, dangerous situations or damage to the products or other property can arise from misuse of this device. 4031_en_C PHOENIX CONTACT 5/24 BL2 PPC 1201-4/… The products fulfill the requirements of the EMC directives and harmonized European standards Any modifications to the systems can influence the EMC behavior. The device contains valuable recyclable materials, which should be utilized. The electronic circuit board is fitted with a lithium battery. Dispose of the device separately from other waste, i.e., via an appropriate collection site. Operating display panel at full brightness for long duty cycles and/or at higher ambient temperature may short lifespan of the display. Dim panel when not in use to extend the life of the display. Radio interference These products are Class A items of equipment (EN 55024 and EN 55032). When using the equipment in residential areas, it may cause radio interference. In this case, the operator is obligated to implement appropriate measures. 1.3.2 Product changes Changes or modifications to hardware and software of the device are not permitted. Incorrect operation or modifications to the device can endanger your safety or damage the device. Do not repair the device yourself. If the device is defective, please contact Phoenix Contact. 6/24 PHOENIX CONTACT 4031_en_C Overview and ordering data 2 Overview and ordering data 2.1 Description The BL2 PPC 1201-4/… IPC is a configurable panel PC (PPC) that utilizes the Intel® processors chosen for their balance of processing power, graphic performance, and energy efficiency. The robust design and I/O capability make the BL2 PPC 1201-4/… a product that can be used in a wide variety of applications. Features – – – – – – – Compact, rugged housing Fanless design available Two integrated 10/100/1000 Ethernet ports with independent MAC addresses IP65 rating (front), IP20 rating (back) Two UEFI-configurable RS-232/422/485 communication ports Up to 4 GB RAM USB 2.0 and 3.0 ports 2.2 Ordering data Products Description Industrial panel PC, Intel® Celeron® processor N3350 1.10/2.40 GHz, 7-inch display, 4 GB of RAM, 64 GB mSATA SSD, and Windows 10 IoT Enterprise LTSC 2019 Industrial panel PC, Intel® Celeron® processor N3350 1.10/2.40 GHz, 10-inch display, 4 GB of RAM, 128 GB mSATA SSD, and Windows 10 IoT Enterprise LTSC 2019 Accessories Description Visit phoenixcontact.net/products for available accessories Replacement parts Description Connector, printed circuit board connector 4031_en_C Type BL2 PPC7 1201-4/64-W10 Order No. 1274012 Pcs./Pkt. 1 BL2 PPC10 1201-4/128W10 1274014 1 Type Order No. Pcs./Pkt. Type MC 1,5/ 2-STF-3,81 Order No. 1827703 Pcs./Pkt. 1 PHOENIX CONTACT 7/24 BL2 PPC 1201-4/… 8/24 PHOENIX CONTACT 4031_en_C Installation 3 Installation NOTE: Exceeding the system temperature limits can result in performance degradation of any or all components. Install the BL2 PPC 1201-4/… with adequate clearance around the heat sink and provide a minimum of 0.5 m/s air flow so that ambient air temperatures do not exceed the operation limits. Insert cooling fan(s) in the enclosure, if necessary. Connectors and switches must be accessible. When installing the BL2 PPC 1201-4/… in a enclosure, follow these general rules: – Verify clearances within the cabinet. Typically, leave at least 5 cm (2 in.) on each side with 13 cm (5 in.) on the connector side. – Drill all holes and make all cuts before beginning installation. Be sure to protect already installed components from shavings during this procedure. – Supporting panels must be at least 1.9 mm (14 ga.) to provide proper support. – Make sure that there is adequate space around the heat sink to provide sufficient cooling. 3.1 1. Mounting Cut a hole in the enclosure according to the dimensions for the selected display. X Y Figure 3-1 Panel cutout dimensions Table 3-1 Display cutout dimensions Display size 7 in. 10 in. 4031_en_C X (mm) 186 229 Y (mm) 124 155 PHOENIX CONTACT 9/24 BL2 PPC 1201-4/… Remove the paper seal (1) from the sticky side of the gasket (2) and apply it to the back side of the bezel (3). U S B 2.0 2. P W O E R 1 2 3 Figure 3-2 3. 4. Gasket installation Insert the BL2 PPC 1201-4/… through the opening. Insert the screws (1) through the clamps (2). 1 2 3 Figure 3-3 5. 6. 7. 10/24 PHOENIX CONTACT Panel-mounting clamps From the rear of the enclosure, place a clamp in each slot (3) and slide away from the enclosure panel. Using an alternating pattern, turn each screw clockwise until the BL2 PPC 1201-4/… is secured in the enclosure panel. Torque each clamp screw to 0.88 Nm. 4031_en_C Installation 3.2 Interfaces 3 1 2 USB2.0 POWER 9 8 7 6 9 8 7 6 5 4 3 2 1 5 4 3 2 1 LAN LAN 5 4 3 2 1 9 8 7 6 COM 1 — + DC-IN 9~30V HDMI USB3.0 1 2 3 4 8 7 6 Power switch USB 2.0 port Configurable RS-232/422/485 serial ports Power connector Figure 3-4 5 6 7 8 5 4 HDMI port RS-232 serial port Ethernet RJ45 ports USB 3.0 connectors Connectors and ports (BL2 PPC10 1200 shown) After mounting the BL2 PPC 1201-4/… in the enclosure, make any necessary cable connections (see Figure 3-4) The available connectors are: – Ethernet (ETH): Two RJ45 connectors allow the computer to communicate on a 10/100/1000 Base-T Ethernet network. – Serial (COM): Three D-SUB 9 serial ports are available for use. The default for all ports is RS-232, IIRC. Two ports are configurable as either RS-232, RS-422, or RS-485. – USB (USB): USB devices connect using Type A connectors. Two ports are USB 2.0 and one is USB 3.0. USB 3.0 ports utilize a blue connector. USB 2.0 ports are black. 4031_en_C PHOENIX CONTACT 11/24 BL2 PPC 1201-4/… 3.2.1 Power connection A two-wire removable connector is provided for providing power to the BL2 PPC 1201-4/…. M1 CO — DC -IN + 0V 3 9~ MI HD Figure 3-5 — + Power connector Connect a power source to the included power connector. This connector supports wire sizes from 0.2 to 2.5 mm² (24 to 12 AWG). Torque the wire-retaining screws in the connector to 0.5 Nm (4.4 lbf-in.). Secure the connector to the BL2 PPC 1201-4/… chassis. Table 3-2 Power connector Pin No. Description + 24 V DC ±20% – 0 V DC NOTE: To ensure safe operation, use safety extra-low voltage (SELV) according to DIN EN 61131 as supply voltage. This device is protection class I item of equipment. UEFI is set to boot on power, allowing the system to boot as soon as the power plug is installed. This can be changed in the UEFI. 12/24 PHOENIX CONTACT 4031_en_C Installation 3.2.2 Serial communication Two D-SUB 9 connectors (see Figure 3-4) can be configured to communicate on the RS-232, RS-422, or RS-485 physical layer. The BL2 PPC 1201-4/… is capable of the following communication parameters: Table 3-3 RS-232/422/485 communication settings Data bits RS-232 RS-422/485 Autotoggle RTS RS-422/485 Manual RTS Parity Stop bits None/Even/Odd 1/2 7/8 None/Even/Odd 7/8 None/Even/Odd 8 1/2 1/2 The table shows the capabilities of the IPC. Configuration of parameters to communicate with a specific device is typically part of the software tool performing the communication. The function of the pins in the D-SUB 9 connector varies with the different configuration settings. Table 3-4 D-SUB 9 pin RS-232 RS-422 RS-485 2 RXD TXD+ TXD+/RXD+ 1 3 4 5 6 7 8 9 4031_en_C D-SUB 9 pinout DCD TXD DTR GND DSR RTS CTS Ring indicator TXD- RXD+ RXDGND – – – – TXD-/RXD– – GND – – – – PHOENIX CONTACT 13/24 BL2 PPC 1201-4/… 3.3 Antenna P W O R E An optional factory-installed mini PCIe card is available to allow the BL2 PPC 1201-4/… to be placed on a wireless network. Included with the installed card is an antenna (1) that attaches to a connector on the side of the unit (2). U S B 0 2. 1 3 2 Figure 3-6 Antenna installation Since the BL2 PPC 1201-4/… is often installed within an enclosure, it may be advisable to install the antenna on the exterior of the enclosure rather than directly to the IPC. To do this, an appropriate length antenna cable (3) must be purchased separately. The antenna or antenna threads onto the BL2 PPC 1201-4/…. For external antenna mounting, route and secure the antenna cable appropriately within the enclosure. NOTE: Do not allow metal chips to fall within the enclosure when creating the hole for mounting the antenna. Installation of the miniPCI card for wireless communication voids the UL 61010 listing. 14/24 PHOENIX CONTACT 4031_en_C Technical appendix A Technical appendix A1 Technical data General data Overall, dimensions (width x height x depth)* BL2 PPC7 1201-4/64-W10 196 x 134 x 48 mm BL2 PPC7 1201-4/64-W10 1.2 kg BL2 PPC10 1201-4/128-W10 Ambient temperature (operation)† Ambient temperature (storage/transport) Permissible humidity (relative) Weight BL2 PPC10 1201-4/128-W10 Degree of protection Mounting LED indicators * Dimensions are overall, including bezel † With 0.5 m/s airflow Electrical data Power supply, nominal Type of connection Conductor size Torque, wire clamping screw Current and power data* Current consumption @ 24 V, maximum† 266 x 184 x 48 mm -5 … 50°C -20 … 70°C 10% … 90%, non-condensing 2.9 kg IP65 VESA 75, VESA 100, panel mount 24 V DC ±20% Removable screw-type 0.2 … 2.5 mm² (24 … 12 AWG) 0.5 … 0.6 Nm BL2 PPC7 1201-4/64-W10 1.07 A BL2 PPC7 1201-4/64-W10 25.7 W BL2 PPC10 1201-4/128-W10 Power, maximum @ 24 V, maximum† BL2 PPC10 1201-4/128-W10 1.09 A 26.0 W * Does not include wireless mini PCIe card † Windows 10, SSD and M.2 drives, 8 GB RAM, loopback plugs in all COM and LAN ports, USB ports fully loaded, running Burn-in® tests Operating systems Operating system (configuration option) Windows® 10 IoT Enterprise LTSB 2019 Data storage Type (configurable option) Number of bays RAID support Internal mSATA SSD 1 None 4031_en_C PHOENIX CONTACT 15/24 BL2 PPC 1200 Main memory RAM, maximum Type 4 GB DDR3L Processor data Processor Clock speed Intel Celeron N3350 1.10 GHz Cache Number of cores Number of threads Maximum TDP Number of memory channels 2.40 GHz burst 2 MB 2 2 6W 2 Interfaces USB Serial connection Super I/O chipset Chipset Video out Graphic processor Number of Ethernet connectors Ethernet connection LAN chipset Number of mini PCIe slots* Mini PCIe card size, maximum 1x Type A USB 2.0; 2x Type A USB 3.0 1x D-SUB 9 (male), UEFI selectable for RS-232/422/485 Nuvoton NCT6106D Integrated 1x DP++ Intel HD Graphics 500 2 10/100/1000 Mbps Intel Ethernet controller I211-AT 1 30.00 x 50.95 x 15.00 mm * 16/24 This slot is not available if ordered with the wireless option PHOENIX CONTACT 4031_en_C Technical data Radio module (configurable) Connector type Device interface Frequency band Antenna impedance Frequency range Mini PCIe PCI Express v1.2 IEEE 802.11 a/b/g/n 50  2.4 GHz 2412 ... 2472 Hz 2.4 GHz 802.11b/g 1… 54 Mbps 5 GHz Data transfer rate 5 GHz Transmit power, typical 2.4 GHz (b) 2.4 GHz (g) 5 GHz (a) Display – 7 in. (BL2 PPC7 1201-4/64-W10) Display backlighting type Screen size, diagonal Screen size, horizontal x vertical Resolution Type Brightness Number of colors Backlight life, minimum Contrast ratio View angle, horizontal/vertical (CR=10), typ. Installation cutout dimensions (width x height) 4031_en_C 5180 ... 5825 Hz 802.11a 6 … 54 Mbps 802.11n 2.4/5 GHz MCS0/8 … 7/13 12.5 dBm (Channel 1) 14.5 dBm (Channel 2-10) 11.0 dBm (Channel 11) 13.5 dBm (Channel 1) 14.0 dBm (Channel 2-10, 54 Mbps) 11.5 dBm (Channel 11) 12.5 dBm (Channel 36-165, 6-48 Mbps) 12.0 dBm (Channel 36-165, 54 Mbps) LED 178 mm 153.6 x 90 mm 1024 x 600 Capacitive touch screen 320 Cd/m² 16.2 million 20000 h 1000:1 140°/120 186 x 124 mm PHOENIX CONTACT 17/24 BL2 PPC 1200 Display – 10 in. (BL2 PPC10 1201-4/128-W10) Display backlighting type Screen size, diagonal Screen size, horizontal x vertical Resolution Type Brightness Number of colors Backlight life, minimum Contrast ratio View angle, horizontal/vertical (CR=10), typ. Installation cutout dimensions (width x height) LED 256 mm 217 x 136 mm 1280 x 800 Capacitive touch screen 400 Cd/m² 265,000 25000 h 1300:1 170°/170° 229 x 155 mm Mechanical tests Shock test according to IEC 60068-2-27 Vibration resistance according to EN 60068-2-6 20g with 11 ms duration 3g, 5-500 Hz Approvals CE compliant FCC Part 15 Class A UL/cUL UL 61010* * 18/24 Installation of the miniPCI card for wireless communication voids the UL 61010 listing. Use of the VESA mount (outside an enclosure) removes the UL 61010 listing PHOENIX CONTACT 4031_en_C Appendixes B Appendixes B1 List of figures Section 3 4031_en_C Figure 3-1: Panel cutout dimensions ....................................................................... 9 Figure 3-2: Gasket installation .............................................................................. 10 Figure 3-3: Panel-mounting clamps ...................................................................... 10 Figure 3-4: Connectors and ports (BL2 PPC10 1200 shown) ............................... 11 Figure 3-5: Power connector ................................................................................. 12 Figure 3-6: Antenna installation ............................................................................ 14 PHOENIX CONTACT 19/24 BL2 PPC 1200 20/24 PHOENIX CONTACT 4031_en_C List of tables B2 List of tables Section 3 4031_en_C Table 3-1: Display cutout dimensions ..................................................................... 9 Table 3-2: Power connector.................................................................................. 12 Table 3-3: RS-232/422/485 communication settings ............................................ 13 Table 3-4: D-SUB 9 pinout.................................................................................... 13 PHOENIX CONTACT 21/24 BL2 PPC 1200 22/24 PHOENIX CONTACT 4031_en_C Please observe the following notes General terms and conditions of use for technical documentation Phoenix Contact reserves the right to alter, correct, and/or improve the technical documentation and the products described in the technical documentation at its own discretion and without giving prior notice, insofar as this is reasonable for the user. The same applies to any technical changes that serve the purpose of technical progress. The receipt of technical documentation (in particular user documentation) does not constitute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observing the applicable standards and regulations. All information made available in the technical data is supplied without any accompanying guarantee, whether expressly mentioned, implied or tacitly assumed. In general, the provisions of the current standard Terms and Conditions of Phoenix Contact apply exclusively, in particular as concerns any warranty liability. This manual, including all illustrations contained herein, is copyright protected. Any changes to the contents or the publication of extracts of this document is prohibited. Phoenix Contact reserves the right to register its own intellectual property rights for the product identifications of Phoenix Contact products that are used here. Registration of such intellectual property rights by third parties is prohibited. Other product identifications may be afforded legal protection, even where they may not be indicated as such. PHOENIX CONTACT 23/24 24 Internet How to contact us Up-to-date information on Phoenix Contact products and our Terms and Conditions can be found on the Internet at: phoenixcontact.com Make sure you always use the latest documentation. It can be downloaded at: phoenixcontact.net/products Subsidiaries If there are any problems that cannot be solved using the documentation, please contact your Phoenix Contact subsidiary. Subsidiary contact information is available at phoenixcontact.com. Published by PHOENIX CONTACT GmbH & Co. KG Flachsmarktstraße 8 32825 Blomberg GERMANY PHOENIX CONTACT Development and Manufacturing, Inc. 586 Fulling Mill Road Middletown, PA 17057 USA Should you have any suggestions or recommendations for improvement of the contents and layout of our manuals, please send your comments to: tecdoc@phoenixcontact.com 24/24 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany phoenixcontact.com
1274014 价格&库存

很抱歉,暂时无法提供与“1274014”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1274014
  •  国内价格 香港价格
  • 1+17595.995281+2127.10748

库存:2