0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1344364

1344364

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    断路器 10A AC 30 V DC 按片 DIN 轨道

  • 数据手册
  • 价格&库存
1344364 数据手册
CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Please be informed that the data shown in this PDF document is generated from our online catalog. Please find the complete data in the user documentation. Our general terms of use for downloads are valid. 2-channel electronic circuit breaker module for protecting 12 V DC and 24 V DC loads against overload and short circuit. Nominal current adjustable from 2 A to 10 A via step switch. EX e approval for zone 2. For DIN rail installation via the CAPAROC current rails. Your advantages • The customizable standard, thanks to individual combinations of the future-proof modular system • Easy operation for everyone through tool-free assembly, uninterrupted installation, and transparent operating state • Strikingly simple design-in with extensive support from the selection up to digital services Commercial data Item number 1344364 Packing unit 1 pc Minimum order quantity 1 pc Sales key CL11 Product key CLA233 GTIN 4063151658120 Weight per piece (including packing) 96.7 g Weight per piece (excluding packing) 89.55 g Customs tariff number 85363010 Country of origin DE Jan 8, 2024, 9:55 AM Page 1 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Technical data Notes General Note LABS release – in accordance with test specification VW PV 3. 10.7:2005-0 When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules. Observe the specified conditions for use in potentially explosive areas. Install the device in a suitable approved housing with at least IP54 degree of protection that meets the requirements of IEC/EN 60079-0. Also observe the requirements of IEC/EN 60079-14. Product properties Type Plug-in module Product type Device circuit breakers Product family CAPAROC Number of positions 1 No. of channels 2 Number of slots 2 Insulation characteristics Protection class III Pollution degree 2 Electrical properties No. of channels 2 General Operating voltage 10 V DC ... 30 V DC Rated voltage 12 V DC 24 V DC Rated current IN 10 A DC (per channel) Rated current IN 2 / 4 / 6 / 8 / 10 A DC (Adjustable via rotary coding switches) 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 A DC (can be set, in RC mode via power module with communication interface) Rated current (pre-adjusted) 2A Rated surge voltage 0.5 kV Tripping method E (electronic) Feedback resistance max. 35 V DC Switch-on delay 50 ms (each channel preset by default) can be adapted with CAPAROC PM IOL and CAPAROC PM PN power modules Required backup fuse Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element. Jan 8, 2024, 9:55 AM Page 2 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Short-circuit switching capacity 300 A Dielectric strength 35 V DC (Load circuit) Active current limitation typ. 2.0 x IN at IN ≤ 3 A typ. 1.5 x IN at IN ≥ 4 A Fuse electronic Efficiency > 99 % Closed circuit current I0 typ. 25 mA (no load at 24 V) Power dissipation typ. 0.6 W (no load at 24 V) < 3.3 W (in nominal operation at 24 V and 10 A) Measuring tolerance I ± 10 % (typ.) Temperature derating 20 A (Total current at 40°C) 10 A (Total current at 65 °C) MTBF (IEC 61709, SN 29500) 11140621 h (at 25 °C with 21 % load) 4699883 h (at 40°C with 34.25% load) 534110 h (at 40°C with 100% load) Voltage drop 0.14 V (at 10 A) Fail-safe element 15 A DC (per output channel) Load circuit Shutdown time 5 s (for overload 1.1…1.3 x IN at IN ≥ 4 A) 5 s (for overload 1.1…1.7 x IN at IN < 4 A) typ. 400 ms (max. 450 ms for high starting currents) typ. 20 ms (for short circuit > 1,5 x IN) Undervoltage switch-off ≤ 8.5 V DC (active) ≥ 9.2 V DC (inactive) Overvoltage switch-off ≥ 32.5 V DC (active) ≤ 30.5 V DC (inactive) Max. capacitive load ≤ 75000 µF (Depending on the current setting and the shortcircuit current available) Connection data Fuse-protected output Connection method Push-in connection Stripping length 10 mm Conductor cross section flexible 0.2 mm² ... 4 mm² Conductor cross section rigid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 4 mm² Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 4 mm² Signaling Channel LED off off (Channel switched off) Channel LED yellow lit (Channel switched on, channel load > 80% ) two flashes (Check the installation, no communication to power Jan 8, 2024, 9:55 AM Page 3 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 module) Channel LED green lit (Channel switched on) flashing (Channel switched on, coding switch position is not equal to set value) Channel LED red lit (Channel switched off, over- or undervoltage active) ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release) flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) two flashes (Channel switched off, system total current limit exceeded) Channel LED red-yellow flashing (Channel is overloaded and is switched off) Channel LED red-green flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release) Dimensions Dimensional drawing Width 12.4 mm Height 132.4 mm Depth 111.3 mm (incl. DIN rail 7.5 mm) Material specifications Material PA 6 PA 6 PA 6 PC Flammability rating according to UL 94 V-0 Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -30 °C ... 65 °C (The temperature range of the power module must be taken into consideration) Ambient temperature (storage/transport) -40 °C ... 70 °C Altitude ≤ 4000 m (amsl) Humidity test 96 h, 95 % RH, 40 °C Shock (operation) 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27) 25g (6 ms duration, half-sine shock pulse in accordance with  IEC 60068-2-27, continuous shock) Vibration (operation) 5g (10 ... 150 Hz / 10 cycles / axis / X, Y, Z) Approvals UL approval Identification UL/C-UL Listed UL 508 UL Recognized UL 2367 Jan 8, 2024, 9:55 AM Page 4 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 UL 121201 Class I, Division 2, Groups A, B, C, D, T4A ATEX Identification TÜV 22 ATEX 8874 X II 3G Ex ec IIC T4 Gc IECEx Identification IECEx TUR 22.0049X II 3G Ex ec IIC T4 Gc UKCA Ex (UKEX) Identification TÜV 22 UKEX 7109 X II 3G Ex ec IIC T4 Gc Standards and regulations Standards/specifications EN 61000-6-2 Note EMC – Immunity for industrial areas Standards/specifications EN 61000-6-3 Note EMC – Emission for residential, business and commercial properties and small operations Standards/specifications EN 60068-2-78 Note Environmental influences – Moisture and heat, constant Standards/specifications EN 50178 Note Equipping power installations with electronic equipment Standards/specifications EN 60068-2-6 Note Environmental influences – Vibrations (sinusoidal) Standards/specifications EN 60068-2-27 Note Environmental influences – Shocks Standards/specifications IEC 60079-7 Note Explosive atmospheres – Part 7: Equipment protection by increased safety “e” Standards/specifications IEC 60079-0 Note Explosive atmospheres – Part 0: Equipment – General requirements Mounting Mounting type pluggable onto CAPAROC CR… current rail Jan 8, 2024, 9:55 AM Page 5 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Drawings Diagram t s 1000 Trigger Point 100 10 1 0,1 0,01 0,6 1 1,1 1,7 2 x IN Tripping characteristic < 4 A Jan 8, 2024, 9:55 AM Page 6 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 I [A] Diagram 25 20 15 10 5 0 -40 -20 0 20 40 60  [°C] Max. permissible current in relation to the ambient temperature Jan 8, 2024, 9:55 AM Page 7 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Diagram t s 1000 Trigger Point 100 10 1 0,1 0,01 0,6 1 1,1 1,3 1,5 2 x IN Tripping characteristic ≥ 4 A Jan 8, 2024, 9:55 AM Page 8 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Dimensional drawing 111,3 132,4 12,4 Block diagram IN+ 5.1 IN- 6.1 µC Current limitation CH1 Current limitation CH2 OUT+ 1.1 1.2 2.1 2.2 CH1 CH2 Jan 8, 2024, 9:55 AM Page 9 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Approvals To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1344364 UL Recognized  Approval ID: FILE E 317172  UL Listed  cUL Listed Approval ID: FILE E 123528 Approval ID: FILE E 123528   IECEx Approval ID: IECEx TUR 22.0049X UL Recognized Approval ID: FILE E 324415  cUL Listed  UL Listed Approval ID: FILE E 483407 Approval ID: FILE E 483407 X ATEX  UKCA-EX Approval ID: TÜV 22 ATEX 8874 X Approval ID: TÜV 22 UKEX 7109 X cULus Listed cULus Listed Jan 8, 2024, 9:55 AM Page 10 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Classifications ECLASS ECLASS-11.0 27140401 ECLASS-12.0 27140401 ECLASS-13.0 27140401 ETIM ETIM 9.0 EC003538 Jan 8, 2024, 9:55 AM Page 11 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 Mandatory accessories CAPAROC CR 20 - Busbar 1110989 https://www.phoenixcontact.com/us/products/1110989 Busbar for CAPAROC system with 20 slots. For installation on a DIN rail. CAPAROC CR 8 - Busbar 1115672 https://www.phoenixcontact.com/us/products/1115672 Busbar for the CAPAROC system with 8 slots. For installation on a DIN rail. CAPAROC PM S-R EX - Power module 1344363 https://www.phoenixcontact.com/us/products/1344363 Power module with status output and reset input for supplying the CAPAROC circuit breaker system with 12 V DC or 24 V DC. EX e approval for zone 2. For DIN rail installation via the CAPAROC current rails. Accessories Jan 8, 2024, 9:55 AM Page 12 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 CAPAROC PD 0V - Potential distributors 1110987 https://www.phoenixcontact.com/us/products/1110987 Potential distributor with Push-in connections for directly connecting the 0 V return conductor in the CAPAROC system. For DIN rail installation via the CAPAROC current rails. UC-TMF 6 - Marker for terminal blocks 0818140 https://www.phoenixcontact.com/us/products/0818140 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snapped, for terminal block width: 6.2 mm, lettering field size: 5.6 x 5.1 mm, Number of individual labels: 80 UCT-TMF 6 - Marker for terminal blocks 0828746 https://www.phoenixcontact.com/us/products/0828746 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snapped, for terminal block width: 6.2 mm, lettering field size: 5.4 x 4.7 mm, Number of individual labels: 60 Jan 8, 2024, 9:55 AM Page 13 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 UC-TM 12 - Marker for terminal blocks 0819194 https://www.phoenixcontact.com/us/products/0819194 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: snapped, for terminal block width: 12 mm, lettering field size: 11.45 x 10.5 mm, Number of individual labels: 40 UCT-TM 12 - Marker for terminal blocks 0829144 https://www.phoenixcontact.com/us/products/0829144 Marker for terminal blocks, Sheet, white, unlabeled, can be labeled with: TOPMARK NEO, TOPMARK LASER, BLUEMARK ID COLOR, BLUEMARK ID, BLUEMARK CLED, THERMOMARK PRIME, THERMOMARK CARD 2.0, THERMOMARK CARD, mounting type: snapped, for terminal block width: 12 mm, lettering field size: 10.8 x 9.6 mm, Number of individual labels: 30 CAPAROC CR EXT20 - Busbar 1115674 https://www.phoenixcontact.com/us/products/1115674 Extension busbar with 20 slots for the CAPAROC system. For installation on a DIN rail. Jan 8, 2024, 9:55 AM Page 14 (15) CAPAROC E2 12-24DC/2-10A EX - Electronic circuit breaker 1344364 https://www.phoenixcontact.com/us/products/1344364 CAPAROC CR EXT8 - Busbar 1110990 https://www.phoenixcontact.com/us/products/1110990 Extension busbar with 8 slots for CAPAROC system. For installation on a DIN rail. CAPAROC CR EXT4 - Busbar 1110991 https://www.phoenixcontact.com/us/products/1110991 Extension busbar with 4 slots for the CAPAROC system. For installation on a DIN rail. CAPAROC CR CON - Metal part 1270955 https://www.phoenixcontact.com/us/products/1270955 Metal extension rails from connecting CAPAROC initial busbars. Phoenix Contact 2024 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Jan 8, 2024, 9:55 AM Page 15 (15)
1344364 价格&库存

很抱歉,暂时无法提供与“1344364”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1344364
  •  国内价格 香港价格
  • 1+931.922821+115.60460
  • 5+882.674015+109.49530
  • 10+831.1319410+103.10153
  • 50+813.1407050+100.86973

库存:11