Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Assembled Ethernet cable, CAT5e, shielded, 2-pair, AWG 26 stranded (7-wire), RAL 5021 (water blue), M12
flush-type socket, front/screw mounting with M16 thread on free conductor end, line, length 2 m
Your advantages
Pre-assembled with cables in various standard lengths for immediate use
Customer-specific assemblies and cable lengths can be supplied
Sealed on the cable side for optimum tightness of seal
Cable designs for all common networks and fieldbuses
For high transmission safety: shield connection to the housing with optional EMC nut
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356475969
Weight per Piece (excluding packing)
120.000 g
Custom tariff number
85444290
Country of origin
Germany
Technical data
Ambient conditions
Degree of protection
IP65
IP67
Ambient temperature (operation)
-40 °C ... 70 °C (Plug / socket)
-50 °C ... 70 °C (cable, flexible installation)
-20 °C ... 60 °C (cable, fixed installation)
01/17/2020 Page 1 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Technical data
General data
Note
The electrical and mechanical data specified assume that the connector
pair is correctly locked and mounted. If the connector is unlocked and if
there is a danger of contamination, the connector must be sealed using
a protective cap > IP54. Influences arising from litz wires, cables or PCB
assembly must also be taken into consideration.
Rated current at 40°C
4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data
is to be observed)
Rated voltage
250 V
Number of positions
4
Signal type/category
Ethernet CAT5, 100 Mbps
Ethernet
Overvoltage category
II
Degree of pollution
3
Alternative short product description
Ethernet cable
Contact material
CuZn
Contact carrier material
PA 6.6
Contact surface material
Ni/Au
Standards and Regulations
Flammability rating according to UL 94
V0
Safety note
WARNING: The connectors may not be plugged in or disconnected under
load. Ignoring the warning or improper use may damage persons and/or
property.
• WARNING: Commission properly functioning products only. The products
must be regularly inspected for damage. Decommission defective products
immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• When operating the connectors in outdoor applications, they must be
separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the
standards listed (e.g. the ones listed in the product accessories online at
phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
01/17/2020 Page 2 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Technical data
Standards and Regulations
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly
connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are
applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient
conditions, the surface of the connector can continue to warm up. In
this case, the user is responsible for posting warnings (e.g. DIN EN ISO
13732-1:2008-12).
Cable
Cable type
PUR ETHERNET 2x2 FLEX
Cable type (abbreviation)
93E
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT5 (IEC 11801), 100 Mbps
Cable structure
2x2xAWG26/7; SF/UTP
Conductor cross section
2x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.98 mm
Wire colors
white/orange-orange, white/green-green
Twisted pairs
2 cores to the pair
Overall twist
Two pairs with two fillers to the core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
1.2 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4xD
Minimum bending radius, flexible installation
8xD
Tensile strength GRP
≤ 80 N
Cable weight
42 kg/km
01/17/2020 Page 3 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Technical data
Cable
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Standards/specifications
Electrical requirements EN 50288-2-2
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
approx. 45 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Return loss (RL)
23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
01/17/2020 Page 4 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Technical data
Cable
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Current carrying capacity of cable
2 A (according to DIN VDE 0891-1)
Flame resistance
according to IEC 60332-1-2
in acc. to UL VW1
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C ... 80 °C
Ambient temperature (storage/transport)
-20 °C ... 80 °C
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
01/17/2020 Page 5 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Dimensional drawing
M12 flush-type connector
01/17/2020 Page 6 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Dimensional drawing
Housing cutout for M16 fastening thread, mounting panel with thread
01/17/2020 Page 7 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Cable cross section
PUR ETHERNET 2x2 FLEX [93E]
Classifications
eCl@ss
eCl@ss 4.0
24010400
eCl@ss 4.1
24010400
eCl@ss 5.0
19030300
eCl@ss 5.1
19030300
eCl@ss 6.0
27061800
eCl@ss 7.0
27060308
eCl@ss 8.0
27060308
01/17/2020 Page 8 / 9
https://www.phoenixcontact.com/us/products/1405837
Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837
Classifications
eCl@ss
eCl@ss 9.0
27060308
ETIM
ETIM 3.0
EC001262
ETIM 4.0
EC001262
ETIM 5.0
EC002599
ETIM 6.0
EC001262
ETIM 7.0
EC001262
UNSPSC
UNSPSC 6.01
26121616
UNSPSC 7.0901
26121616
UNSPSC 11
26121604
UNSPSC 12.01
31261501
UNSPSC 13.2
26121604
UNSPSC 18.0
26121604
UNSPSC 19.0
26121604
UNSPSC 20.0
26121604
UNSPSC 21.0
26121604