1405837

1405837

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CABLE

  • 数据手册
  • 价格&库存
1405837 数据手册
https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Assembled Ethernet cable, CAT5e, shielded, 2-pair, AWG 26 stranded (7-wire), RAL 5021 (water blue), M12 flush-type socket, front/screw mounting with M16 thread on free conductor end, line, length 2 m Your advantages  Pre-assembled with cables in various standard lengths for immediate use  Customer-specific assemblies and cable lengths can be supplied  Sealed on the cable side for optimum tightness of seal  Cable designs for all common networks and fieldbuses  For high transmission safety: shield connection to the housing with optional EMC nut Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356475969 Weight per Piece (excluding packing) 120.000 g Custom tariff number 85444290 Country of origin Germany Technical data Ambient conditions Degree of protection IP65 IP67 Ambient temperature (operation) -40 °C ... 70 °C (Plug / socket) -50 °C ... 70 °C (cable, flexible installation) -20 °C ... 60 °C (cable, fixed installation) 01/17/2020   Page 1 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Technical data General data Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Rated current at 40°C 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) Rated voltage 250 V Number of positions 4 Signal type/category Ethernet CAT5, 100 Mbps Ethernet Overvoltage category II Degree of pollution 3 Alternative short product description Ethernet cable Contact material CuZn Contact carrier material PA 6.6 Contact surface material Ni/Au Standards and Regulations Flammability rating according to UL 94 V0 Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. • The products are suitable for applications in plant, controller, and electrical device engineering. • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. • Assembled products may not be manipulated or improperly opened. • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). • When using the product in direct connection with third-party manufacturers, the user is responsible. • For operating voltages > 50 V AC, conductive connector housings must be grounded 01/17/2020   Page 2 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Technical data Standards and Regulations • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product • Only use tools recommended by Phoenix Contact • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products • Ensure that the protective or functional ground has been properly connected. • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Cable Cable type PUR ETHERNET 2x2 FLEX Cable type (abbreviation) 93E UL AWM style 20963 (80°C/30 V) Signal type/category Ethernet CAT5 (IEC 11801), 100 Mbps Cable structure 2x2xAWG26/7; SF/UTP Conductor cross section 2x 2x 0.14 mm² AWG signal line 26 Conductor structure signal line 7x 0.16 mm Core diameter including insulation 0.98 mm Wire colors white/orange-orange, white/green-green Twisted pairs 2 cores to the pair Overall twist Two pairs with two fillers to the core Shielding Aluminum-coated foil, tinned copper braided shield Optical shield covering 70 % External sheath, color water blue RAL 5021 Outer sheath thickness 1.2 mm External cable diameter D 6.4 mm ±0.2 mm Minimum bending radius, fixed installation 4xD Minimum bending radius, flexible installation 8xD Tensile strength GRP ≤ 80 N Cable weight 42 kg/km 01/17/2020   Page 3 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Technical data Cable Outer sheath, material PUR Material conductor insulation Foamed PE Conductor material Bare Cu litz wires Standards/specifications Electrical requirements EN 50288-2-2 Insulation resistance ≥ 500 MΩ*km Loop resistance ≤ 290.00 Ω/km Cable capacity approx. 45 nF/km (at 1 kHz) Wave impedance 100 Ω ±5 Ω (at 100 MHz) Near end crosstalk attenuation (NEXT) 65.3 dB (with 1 MHz) 56.3 dB (at 4 МHz) 50.3 dB (at 10 MHz) 47.2 dB (at 16 MHz) 45.8 dB (at 20 МHz) 42.9 dB (at 31.25 МHz) 38.4 dB (at 62.5 МHz) 35.3 dB (at 100 MHz) Power-summated near end crosstalk attenuation (PSNEXT) 62.3 dB (with 1 MHz) 53.3 dB (at 4 МHz) 47.3 dB (at 10 MHz) 44.2 dB (at 16 MHz) 42.8 dB (at 20 МHz) 39.9 dB (at 31.25 МHz) 35.4 dB (at 62.5 МHz) 32.3 dB (at 100 MHz) Attenuation 3.2 dB (with 1 MHz) 6 dB (at 4 МHz) 9.5 dB (at 10 MHz) 12.1 dB (at 16 MHz) 13.6 dB (at 20 МHz) 17.1 dB (at 31.25 МHz) 24.8 dB (at 62.5 МHz) 32 dB (at 100 MHz) Return loss (RL) 23 dB (at 4 МHz) 24.1 dB (at 8 МHz) 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20 МHz) 01/17/2020   Page 4 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Technical data Cable 23.6 dB (at 31.25 МHz) 21.5 dB (at 62.5 МHz) 20.1 dB (at 100 MHz) Signal runtime 5.3 ns/m Coupling resistance ≤ 100.00 mΩ/m (at 10 MHz) Nominal voltage, cable ≤ 100 V (Peak value, not for high-power applications) Test voltage Core/Core 700 V (50 Hz, 1 min.) Test voltage Core/Shield 700 V (50 Hz, 1 min.) Current carrying capacity of cable 2 A (according to DIN VDE 0891-1) Flame resistance according to IEC 60332-1-2 in acc. to UL VW1 Halogen-free according to IEC 60754-1 Resistance to oil according to EN 60811-2-1 Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation) -20 °C ... 80 °C (cable, flexible installation) Ambient temperature (installation) -20 °C ... 80 °C Ambient temperature (storage/transport) -20 °C ... 80 °C Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 01/17/2020   Page 5 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Dimensional drawing M12 flush-type connector 01/17/2020   Page 6 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Dimensional drawing Housing cutout for M16 fastening thread, mounting panel with thread 01/17/2020   Page 7 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Cable cross section PUR ETHERNET 2x2 FLEX [93E] Classifications eCl@ss eCl@ss 4.0 24010400 eCl@ss 4.1 24010400 eCl@ss 5.0 19030300 eCl@ss 5.1 19030300 eCl@ss 6.0 27061800 eCl@ss 7.0 27060308 eCl@ss 8.0 27060308 01/17/2020   Page 8 / 9 https://www.phoenixcontact.com/us/products/1405837 Network cable - VS-M12FSEC-OE-93E-LI/2,0 - 1405837 Classifications eCl@ss eCl@ss 9.0 27060308 ETIM ETIM 3.0 EC001262 ETIM 4.0 EC001262 ETIM 5.0 EC002599 ETIM 6.0 EC001262 ETIM 7.0 EC001262 UNSPSC UNSPSC 6.01 26121616 UNSPSC 7.0901 26121616 UNSPSC 11 26121604 UNSPSC 12.01 31261501 UNSPSC 13.2 26121604 UNSPSC 18.0 26121604 UNSPSC 19.0 26121604 UNSPSC 20.0 26121604 UNSPSC 21.0 26121604 Approvals Approvals Approvals EAC Ex Approvals Approval details EAC      B.00767 Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 01/17/2020   Page 9 / 9
1405837 价格&库存

很抱歉,暂时无法提供与“1405837”相匹配的价格&库存,您可以联系我们找货

免费人工找货