https://www.phoenixcontact.com/us/products/1407331
Sensor/Actuator cable - SAC-5P- 2,0-28R/FS SCO RAIL - 1407331
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 5-position, PE-X halogen-free, black, shielded, free cable end, on Socket straight M12
SPEEDCON, A-coded, Cable length: 2 m, For railway applications
Why buy this product
Easy and safe: 100% electrically tested plug-in components
Safety thanks to flame retardancy: PA 6.6 grip and radiation-cross-linked cables satisfy the most stringent requirements
Securely locked by special vibration brake
Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356774475
Weight per Piece (excluding packing)
163.600 g
Custom tariff number
85444290
Country of origin
Poland
Technical data
Dimensions
Length of cable
2m
Ambient conditions
Ambient temperature (operation)
-40 °C ... 85 °C (Plug / socket)
Degree of protection
IP65
12/01/2016 Page 1 / 4
https://www.phoenixcontact.com/us/products/1407331
Sensor/Actuator cable - SAC-5P- 2,0-28R/FS SCO RAIL - 1407331
Technical data
General
Rated current at 40°C
4A
Rated voltage
60 V
Number of positions
5
Insulation resistance
≥ 100 MΩ
Coding
A - standard
Standards/regulations
M12 connector IEC 61076-2-101
Shock, vibration EN 50155
Status display
No
Protective circuit/component
Unwired
Overvoltage category
II
Degree of pollution
3
Insertion/withdrawal cycles
≥ 100
Torque
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
V0
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material of grip body
PA 6.6
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Standards/regulations
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and
R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards and Regulations
Standard designation
M12 connector
Standards/regulations
IEC 61076-2-101
Standard designation
Shock, vibration
Standards/regulations
EN 50155
Flammability rating according to UL 94
V0
Cable
Cable type
Shielded black RADOX
Cable type (abbreviation)
28R
Conductor cross section
5x 0.5 mm²
AWG signal line
20
Conductor structure signal line
19x 0.18 mm
Core diameter including insulation
1.43 mm
®
12/01/2016 Page 2 / 4
https://www.phoenixcontact.com/us/products/1407331
Sensor/Actuator cable - SAC-5P- 2,0-28R/FS SCO RAIL - 1407331
Technical data
Cable
Wire colors
White 1, white 2, white 3, white 4, white 5
Overall twist
5 cores, twisted
Shielding
Tinned copper braided shield
External sheath, color
black
External cable diameter D
6.2 mm ±0,3 mm
Minimum bending radius, fixed installation
3xD
Minimum bending radius, flexible installation
4xD
Cable weight
70 kg/km
Outer sheath, material
PE-X
Material conductor insulation
PE-X
Conductor material
Tin-plated Cu litz wires
Conductor resistance
≤ 40.1 Ω/km
Nominal voltage, cable
600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
Test voltage, cable
3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
Fire protection in rail vehicles
BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistance
EN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-free
According to EN 50267-2-1
Resistance to oil
according to IRM 902, 72 h at 100 °C
12/01/2016 Page 3 / 4
https://www.phoenixcontact.com/us/products/1407331
Sensor/Actuator cable - SAC-5P- 2,0-28R/FS SCO RAIL - 1407331
Technical data
Cable
Other resistance
Resistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumes
BS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness
EN 50267-2-2
Fume toxicity
BS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)
-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Drawings
Schematic diagram
3
Cable cross section
4
5
2
1
Pin assignment M12 socket, 5-pos., A-coded, socket side view
®
Shielded black RADOX [28R]
Dimensional drawing
Circuit diagram
Socket M12-SPEEDCON, straight, shielded
M12
Ø14,8
Ø16
44
1
WH 1
2
WH 4
4
WH 3
3
WH 2
5
WH 5
Contact assignment of the M12 socket
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
12/01/2016 Page 4 / 4