https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Network cable, Ethernet CAT6A (10 Gbps), CC-Link IE CAT6A (10 Gbps), 8-position, PUR halogen-free, water
blue RAL 5021, shielded, Plug straight M12 SPEEDCON / IP67, coding: X, on Plug straight M12 SPEEDCON /
IP67, coding: X, cable length: 5 m
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356777643
Weight per Piece (excluding packing)
260.000 g
Custom tariff number
85444290
Country of origin
Poland
Technical data
Dimensions
Length of cable
5m
Ambient conditions
Degree of protection
IP65
IP67
Ambient temperature (operation)
-25 °C ... 90 °C (M12 connector)
General data
Note
Further products with variable cable type and variable cable length can be
found in the accessories section
Rated current at 40°C
0.5 A
07/15/2019 Page 1 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Technical data
General data
Rated voltage
48 V AC
60 V DC
Number of positions
8
Signal type/category
Ethernet CAT6A, 10 Gbps
CC-Link IE CAT6A, 10 Gbps
Standards/regulations
M12 connector IEC 61076-2-109
Contact material
CuSn
Contact carrier material
PP
Contact surface material
Ni/Au
Characteristics head 1
Head type
Plug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern)
8
Coding
X (Data)
Color
black
Material (component)
CuZn (Contact)
Ni/Au (Contact surface)
PP (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Insulation resistance
≥ 100 MΩ
Insertion/withdrawal cycles
≥ 100
Torque
0.4 Nm
Ambient temperature (operation)
-25 °C ... 90 °C
Characteristics head 2
Head type
Plug straight M12 SPEEDCON / IP67
No. of positions (pin connector pattern)
8
Coding
X (Data)
Color
black
black
Material (component)
CuZn (Contact)
Ni/Au (Contact surface)
PP (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Insulation resistance
≥ 100 MΩ
Insertion/withdrawal cycles
≥ 100
07/15/2019 Page 2 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Technical data
Characteristics head 2
Torque
0.4 Nm
Ambient temperature (operation)
-25 °C ... 90 °C
Standards and Regulations
Standard designation
M12 connector
Standards/regulations
IEC 61076-2-109
Cable
Cable type
Ethernet 10 Gbit
Cable type (abbreviation)
94F
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT6A, 10 Gbps
Cable structure
4x2xAWG26/7; S/FTP
Conductor cross section
4x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
1.04 mm
Wire colors
white/blue-blue, white/orange-orange, white/green-green, white/brownbrown
Twisted pairs
2 cores to the pair
Type of pair shielding
Aluminum-lined foil
Overall twist
4 pairs for core
Shielding
Tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
0.65 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4xD
Minimum bending radius, flexible installation
8xD
Tensile strength GRP
≤ 100 N
Cable weight
42 kg/km
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
47 nF/km
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
75.3 dB (with 1 MHz)
07/15/2019 Page 3 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Technical data
Cable
66.3 dB (at 4 МHz)
61.8 dB (at 8 МHz)
60.3 dB (at 10 MHz)
57.2 dB (at 16 MHz)
55.8 dB (at 20 МHz)
54.3 dB (at 25 MHz)
52.8 dB (at 31.25 МHz)
48.4 dB (at 62.5 МHz)
45.3 dB (at 100 MHz)
40.8 dB (at 200 MHz)
39.3 dB (at 250 MHz)
38.1 dB (at 300 MHz)
36.3 dB (at 400 MHz)
34.8 dB (at 500 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
72.3 dB (with 1 MHz)
63.3 dB (at 4 МHz)
58.8 dB (at 8 МHz)
57.3 dB (at 10 MHz)
54.2 dB (at 16 MHz)
52.8 dB (at 20 МHz)
51.3 dB (at 25 MHz)
49.9 dB (at 31.25 МHz)
45.4 dB (at 62.5 МHz)
42.3 dB (at 100 MHz)
37.8 dB (at 200 MHz)
36.3 dB (at 250 MHz)
35.1 dB (at 300 MHz)
33.3 dB (at 400 MHz)
31.8 dB (at 500 MHz)
Attenuation
3.1 dB (with 1 MHz)
5.7 dB (at 4 МHz)
8 dB (at 8 МHz)
8.9 dB (at 10 MHz)
11.2 dB (at 16 MHz)
12.6 dB (at 20 МHz)
14.1 dB (at 25 MHz)
15.8 dB (at 31.25 МHz)
07/15/2019 Page 4 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Technical data
Cable
22.5 dB (at 62.5 МHz)
28.7 dB (at 100 MHz)
41.4 dB (at 200 MHz)
46.6 dB (at 250 MHz)
51.4 dB (at 300 MHz)
60.1 dB (at 400 MHz)
67.9 dB (at 500 MHz)
Return loss (RL)
20 dB (with 1 MHz)
23 dB (at 4 МHz)
24.5 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
24.2 dB (at 25 MHz)
23.3 dB (at 31.25 МHz)
20.7 dB (at 62.5 МHz)
19 dB (at 100 MHz)
16.4 dB (at 200 MHz)
15.6 dB (at 250 MHz)
15.6 dB (at 300 MHz)
15.6 dB (at 400 MHz)
15.6 dB (at 500 MHz)
Signal runtime
5.13 ns/m
Shield attenuation
≥ 80 dB (at 30 ... 100 MHz)
Nominal voltage, cable
≤ 100 V
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
according to IEC 60332-1-2
Halogen-free
according to IEC 60754-1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C ... 80 °C
Ambient temperature (storage/transport)
-20 °C ... 80 °C
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
07/15/2019 Page 5 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Schematic diagram
5
Cable cross section
4
6
3
7
2
8
1
Pin assignment of M12 plug, 8-pos., X-coded, pin side view
Ethernet 10 Gbit [94F]
Circuit diagram
M12
2 OG
3
3 WH/GN
4
4 GN
5
5 WH/BN
6
6 BN
7
7 WH/BU
8
8 BU
47,3
Ø12
1 WH/OG
2
M12
1
Ø14,8
M12
Dimensional drawing
M12 SPEEDCON plug, straight, shielded
Contact assignment of the M12 plugs
Classifications
eCl@ss
eCl@ss 4.0
27060307
eCl@ss 4.1
27060307
eCl@ss 5.0
27060307
eCl@ss 5.1
19030300
eCl@ss 6.0
27061800
eCl@ss 7.0
27061801
eCl@ss 8.0
27061801
eCl@ss 9.0
27060308
07/15/2019 Page 6 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Classifications
ETIM
ETIM 3.0
EC000830
ETIM 4.0
EC001855
ETIM 5.0
EC002599
ETIM 6.0
EC000830
ETIM 7.0
EC003249
UNSPSC
UNSPSC 6.01
26121616
UNSPSC 7.0901
26121616
UNSPSC 11
26121604
UNSPSC 12.01
31261501
UNSPSC 13.2
31251501
Approvals
Approvals
Approvals
UL Listed / EAC / cUL Listed / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
30 V
Nominal current IN
0.5 A
EAC
FILE E 335024
RU CDE.AI30.B.00767
07/15/2019 Page 7 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Approvals
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
30 V
Nominal current IN
0.5 A
cULus Listed
FILE E 335024
Accessories
Accessories
Data cable preassembled
Network cable - NBC-MSX-MSX SCO-10G/.../... - 1408644
Network cable, Ethernet CAT6A (10 Gbps), CC-Link IE CAT6A (10 Gbps), 8-position, Variable cable type, shielded, Plug
straight M12 SPEEDCON / IP67, coding: X, on Plug straight M12 SPEEDCON / IP67, coding: X, cable length: Free input
(0.2 ... 40.0 m)
Protective cap
Sealing cap - PROT-M12 FS-PA-CHAIN - 1430873
M12 sealing cap made of plastic with fixing band, for sensor cables, for free M12 plugs
Safety locking
Locking clip - SAC-M12-EXCLIP-M - 1558988
Locking clip for the pin side of sensor/actuator cables with M12 connector and M12 connectors for assembly, for knurl
diameter: 15 mm or for Allen key with a wrench size of 14 mm, prevents the disconnection of plug-in connections without
tools
07/15/2019 Page 8 / 9
https://www.phoenixcontact.com/us/products/1407485
Network cable - NBC-MSX/ 5,0-94F/MSX SCO - 1407485
Accessories
Screwdriver tools
Adapter insert - TSD-M SAC-BIT ADAPTER - 1212600
Adapter bit for TSD-M...torque tools, E6.3-1/4" drive with 4 mm hexagon to accommodate SAC bits
Tool - SAC BIT M12-D15 - 1208432
Nut for assembling sensor/actuator cables with M12 connector and M12 connectors for assembly, with a knurl diameter
of 15 mm, for 4 mm hexagonal drive
Torque tool
Torque screwdriver - TSD 04 SAC - 1208429
Torque screwdriver, with preset torque of 0.4 Nm and 4 mm hexagonal drive for M12 connectors
Torque screwdriver - TSD-M 1,2NM - 1212224
Torque screw driver, accuracy as per EN ISO 6789 standard, adjustable from 0.3 ‑ 1.2 Nm
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
07/15/2019 Page 9 / 9