0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1408575

1408575

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    HC-D 7-ESTC-COD

  • 数据手册
  • 价格&库存
1408575 数据手册
https://www.phoenixcontact.com/us/products/1408575 Contact insert - HC-D 7-ESTC-COD - 1408575 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) HEAVYCON male insert, D7 series, 7-pos. + PE, crimp connection with coding option Key Commercial Data Packing unit 1 pc Minimum order quantity 10 pc Weight per Piece (excluding packing) 14.0 g Custom tariff number 85366990 Country of origin Germany Technical data General Note For HC-D7 housing, crimp contacts CK1,6-ED (crimp contacts not included in scope of supply) Connection method Crimp connection Screw connection (PE connection) Degree of pollution 3 Overvoltage category III Constructional and testing regulations DIN VDE 0627/86 DIN VDE 0110/02.79 DIN VDE 0110-1/04.97 IEC 60664-1, DIN IEC 60512 IEC 60352 Number of positions 7+PE Insertion/withdrawal cycles ≥ 500 Size D7 Connection in acc. with standard IEC / EN 03/14/2016   Page 1 / 5 https://www.phoenixcontact.com/us/products/1408575 Contact insert - HC-D 7-ESTC-COD - 1408575 Technical data General Conductor cross section 0.14 mm² ... 2.5 mm² Connection cross section AWG 26 ... 14 Stripping length of the individual wire 8 mm 6 mm (2.5 mm²) Assembly instructions Connectors may be operated only when there is no load/voltage. Connection Four different coding possibilities to prevent incorrect plugging. Ambient conditions Ambient temperature (operation) -40 °C ... 125 °C (including heating up of contacts) Material data Flammability rating according to UL 94 V0 Seal material NBR Contact material Copper alloy Contact surface material Ag (alternatively Au) Contact carrier material PC Electrical characteristics Rated voltage (III/3) 400 V Rated surge voltage 6 kV Rated current 10 A Standards and Regulations Connection in acc. with standard IEC / EN CUL Constructional and testing regulations DIN VDE 0627/86 DIN VDE 0110/02.79 DIN VDE 0110-1/04.97 IEC 60664-1, DIN IEC 60512 IEC 60352 Flammability rating according to UL 94 V0 Classifications eCl@ss eCl@ss 4.0 27140816 eCl@ss 4.1 27140816 eCl@ss 5.0 27143424 eCl@ss 5.1 27143424 03/14/2016   Page 2 / 5 https://www.phoenixcontact.com/us/products/1408575 Contact insert - HC-D 7-ESTC-COD - 1408575 Classifications eCl@ss eCl@ss 6.0 27143424 eCl@ss 7.0 27440209 eCl@ss 8.0 27440205 eCl@ss 9.0 27440205 ETIM ETIM 4.0 EC000437 ETIM 5.0 EC000438 UNSPSC UNSPSC 6.01 30211923 UNSPSC 7.0901 39121522 UNSPSC 11 39121522 UNSPSC 12.01 39121522 UNSPSC 13.2 39121522 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / EAC / cULus Recognized Ex Approvals Approvals submitted Approval details UL Recognized      mm²/AWG/kcmil 14 Nominal current IN 10 A Nominal voltage UN 600 V 03/14/2016   Page 3 / 5 https://www.phoenixcontact.com/us/products/1408575 Contact insert - HC-D 7-ESTC-COD - 1408575 Approvals cUL Recognized      mm²/AWG/kcmil 14 Nominal current IN 10 A Nominal voltage UN 600 V EAC  EAC  cULus Recognized  Drawings 7 6 5 4 Diagram Current strength [A] Schematic diagram 1 2 3 Connector pin assignment (connection side) 30,0 27,5 25,0 22,5 20,0 17,5 15,0 12,5 10,0 7,5 5,0 2,5 0 2 1 2 1 = 2,5 mm 2 2 = 1,5 mm 2 3 = 0,75 mm 3 0 20 40 60 80 100 120 Ambient temperature [°C] Derating diagram: HC-D...C series Dimensional drawing 39,5 30,8 21 21 Male insert (turned contacts) 03/14/2016   Page 4 / 5 https://www.phoenixcontact.com/us/products/1408575 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/14/2016   Page 5 / 5
1408575 价格&库存

很抱歉,暂时无法提供与“1408575”相匹配的价格&库存,您可以联系我们找货

免费人工找货