https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Power cable, 4-position, PUR halogen-free, black-gray RAL 7021, Plug angled M12, S-coded, on free cable end,
cable length: 5 m, for AC current up to 12 A/690 V
Your advantages
Easy and safe: 100% electrically tested plug-in components
High-performance: AC connectors for up to 12 A and 690 V AC
Protection against incorrect connection using special S-coding
Our standard: robust halogen-free PUR cable
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356839860
Weight per Piece (excluding packing)
580.000 g
Custom tariff number
85444290
Country of origin
Germany
Technical data
Dimensions
Length of cable
5m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 85 °C (Plug / socket)
Degree of protection
IP65
IP67
07/14/2019 Page 1 / 6
https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Technical data
General
Rated current at 40°C
12 A
Rated voltage
690 V AC
Number of positions
4
Color handle area
black
Insulation resistance
≥ 100 MΩ
Coding
S power
Standards/regulations
M12 connector IEC 61076-2-111
Status display
No
Protective circuit/component
unwired
Overvoltage category
III
Degree of pollution
3
Insertion/withdrawal cycles
> 100
Torque
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
V0
Contact material
CuZn
Contact surface material
Ni/Au
Contact carrier material
PA
Material of grip body
PA
Material, knurls
Zinc die-cast, nickel-plated
Standards and Regulations
Standard designation
M12 connector
Standards/regulations
IEC 61076-2-111
Flammability rating according to UL 94
V0
Cable
Cable type
PUR halogen-free black
Cable type (abbreviation)
PUR
Cable abbreviation
Li9YV1-11Y
UL AWM style
20234 / 10492 (80°C/1000 V)
Conductor cross section
4x 1.5 mm²
AWG power supply
16
Conductor structure, voltage supply
78x 0.15 mm
Core diameter including insulation
2.45 mm ±0.05 mm
Thickness, insulation
≥ 0.36 mm
Wire colors
Black 1, black 2, black 3, green/yellow
Overall twist
4 wires, twisted
07/14/2019 Page 2 / 6
https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Technical data
Cable
Length of twist, overall twist
93 mm
External sheath, color
black-gray RAL 7021
Outer sheath thickness
approx. 1.3 mm
External cable diameter D
8.8 mm ±0.25 mm
Minimum bending radius, fixed installation
5xD
Minimum bending radius, flexible installation
10 x D
Number of bending cycles
2000000
Minimum bending radius, drag chain applications
10 x D
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
10 m/s²
Cable weight
114 kg/km
Outer sheath, material
PUR
Material conductor insulation
PP
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 GΩ*km (at 20 °C)
Conductor resistance
≤ 13 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 1000 V AC
Test voltage, cable
≥ 10000 V AC (Spark test)
Flame resistance
According to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Halogen-free
in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Resistance to oil
According to DIN EN 60811-2-1, 168 h at 100°C
According to UL 758, 168 h at 60°C
Other resistance
Hydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation)
-50 °C ... 80 °C (cable, fixed installation)
-30 °C ... 80 °C (cable, flexible installation)
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
07/14/2019 Page 3 / 6
https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Technical data
Environmental Product Compliance
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Schematic diagram
Cable cross section
5
3
1
2
M12 plug pin assignment, 4-pos., S-coded, plug side view
PUR halogen-free black [PUR]
Dimensional drawing
Circuit diagram
1
BK (1)
2
BK (2)
3
BK (3)
PE
GN/YE
Contact assignment of the M12 plug
M12 x 1 male plug, angled
Classifications
eCl@ss
eCl@ss 4.0
27140815
eCl@ss 4.1
27140815
eCl@ss 5.0
27143423
eCl@ss 5.1
27061800
eCl@ss 6.0
27279200
eCl@ss 7.0
27279218
eCl@ss 8.0
27279218
eCl@ss 9.0
27060311
07/14/2019 Page 4 / 6
https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Classifications
ETIM
ETIM 3.0
EC002061
ETIM 4.0
EC001855
ETIM 5.0
EC001855
ETIM 6.0
EC001855
ETIM 7.0
EC001855
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
31251501
Approvals
Approvals
Approvals
UL Listed / cUL Listed / EAC / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
600 V
Nominal current IN
12 A
mm²/AWG/kcmil
16
FILE E 468743
07/14/2019 Page 5 / 6
https://www.phoenixcontact.com/us/products/1408841
Power cable - SAC-4P-MRS/ 5,0-PUR PE SCO - 1408841
Approvals
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Nominal voltage UN
600 V
Nominal current IN
12 A
mm²/AWG/kcmil
16
EAC
cULus Listed
FILE E 468743
RU CDE.AI30.B.00767
Accessories
Accessories
Protective cap
Sealing cap - PROT-M12 FS - 1560251
M12 sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush-type plugs and I/O devices in the field
Screwdriver tools
Tool - SAC BIT M12-D16 - 1200305
Nut for assembling sensor/actuator cables with M12 connector and M12 connectors for assembly, knurl diameter: 16
mm, for 4 mm hexagonal drive
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
07/14/2019 Page 6 / 6
很抱歉,暂时无法提供与“1408841”相匹配的价格&库存,您可以联系我们找货
免费人工找货