Special Vehicle Inlet for charging station tests, CCS type 2, IEC 62196-3, 125 A / 850 V (DC), 24 V Locking
actuator, Single wires, Length: 2 m
Product Description
Special Vehicle Inlet for charging station tests, solely for laboratory tests, tests with charging stations (EVSE), and further analyses on the infrastructure
side - not for installation in any type of vehicle, cannot be used outside of the laboratory area
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
4580.0 g
Custom tariff number
85366990
Country of origin
Germany
Technical data
Dimensions
Conductor length
2.00 m
General
Product type
Special Vehicle Inlet for charging station tests
Standards/regulations
IEC 62196-3
Charging standard
CCS type 2
Charging mode
Mode 2, 3, 4
Features
Charging power
106 kVA
Number of phases
1
Rated current for power contacts
125 A DC
20 A AC
Rated voltage for power contacts
250 V AC
03/15/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/1410506
Test accessories - EV-T2MBIE24-1ACDC-INFRA - 1410506
Technical data
Features
850 V DC
Rated current for signal contacts
2A
Rated voltage for signal contacts
30 V AC
Type of signal transmission
Pulse width modulation
Temperature monitoring
2x Pt 1000
Number of power contacts
5 (L1, N, PE, DC+, DC-)
Number of signal contacts
2 (CP, PP)
Insertion force
< 100 N
Withdrawal force
< 100 N
Insertion/withdrawal cycles
> 10000
Ambient temperature (operation)
-30 °C ... 50 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude difference for area of application
5000 m (above sea level)
Degree of protection
IP44 (plugged in)
IP55 (in road position)
Locking actuator
Typical power supply at the motor
24 V
Possible power supply range at the motor
22 V ... 26 V
Typical motor current for locking
0.05 A
Max. reverse current of the motor
0.5 A
Max. dwell time with reverse current
1000 ms
Recommended adaptation time
600 ms
Maximum voltage for locking detection
30 V
Service life
> 10000 load cycles
Ambient temperature (operation)
-30 °C ... 50 °C
Length of cable
0.5 m
Classifications
eCl@ss
eCl@ss 4.1
27260701
eCl@ss 5.1
27059110
eCl@ss 6.0
27059290
eCl@ss 8.0
27440590
eCl@ss 9.0
27144706
03/15/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/1410506
Test accessories - EV-T2MBIE24-1ACDC-INFRA - 1410506
Classifications
ETIM
ETIM 4.0
EC002498
ETIM 5.0
EC002498
Drawings
Connection diagram
Dimensional drawing
PE
PP
!126,9
L1
N
L2
L3
DC-
DC+
26,5
R!31
CP
R!41
Pin assignment of Vehicle Inlet
!101,9
51,5
Dimensional drawing, side view
Dimensional drawing
75,9
46
116
104
R24,5
M6
70
Dimensional drawing top view
03/15/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/1410506
Test accessories - EV-T2MBIE24-1ACDC-INFRA - 1410506
Schematic diagram
DC
AC
The Combined Charging System (CCS) principle - standard-compliant charging system for electric vehicles, which supports both conventional AC
charging and fast DC charging. Both Vehicle Connectors fit into the CCS Vehicle Inlet.
03/15/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/1410506
Test accessories - EV-T2MBIE24-1ACDC-INFRA - 1410506
Schematic diagram
DC
[I]
DC
[II]
DC
[III]
DC
[IV]
[V]
Operating instructions
DC
03/15/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/1410506
Test accessories - EV-T2MBIE24-1ACDC-INFRA - 1410506
Schematic diagram
R=∞Ω
R=0Ω
Detection for Vehicle Connector