1413178

1413178

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Cable Assembly, Sensor Actuator Cable

  • 数据手册
  • 价格&库存
1413178 数据手册
https://www.phoenixcontact.com/us/products/1413178 Flush-type connector - SACC-DSI-M12MSB-5CON-M16/0,8 - 1413178 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Key Commercial Data Packing unit 1 pc Minimum order quantity 50 pc GTIN GTIN 4046356991346 Weight per Piece (excluding packing) 34.000 g Custom tariff number 85444290 Country of origin Germany Technical data Dimensions Fixed cable length 0.8 Ambient conditions Ambient temperature (operation) -25 ... -85 General Standards/regulations according to IEC 61076-2-101 Overvoltage category III Mounting type Rear wall/screw mounting Coding B-coded Thread type M16 x 1.5 Cable cross section 0.34 Rated surge voltage 1.5 kV AC Degree of pollution 3 Degree of protection IP67 Number of positions 5 Current 4A 05/16/2020   Page 1 / 4 https://www.phoenixcontact.com/us/products/1413178 Flush-type connector - SACC-DSI-M12MSB-5CON-M16/0,8 - 1413178 Technical data General Voltage 60 V Connection data Connection method Individual wires Standards and Regulations Standards/specifications according to IEC 61076-2-101 Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. • The products are suitable for applications in plant, controller, and electrical device engineering. • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. • Assembled products may not be manipulated or improperly opened. • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). • When using the product in direct connection with third-party manufacturers, the user is responsible. • For operating voltages > 50 V AC, conductive connector housings must be grounded • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product • Only use tools recommended by Phoenix Contact • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products • Ensure that the protective or functional ground has been properly connected. • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector 05/16/2020   Page 2 / 4 https://www.phoenixcontact.com/us/products/1413178 Flush-type connector - SACC-DSI-M12MSB-5CON-M16/0,8 - 1413178 Technical data Standards and Regulations • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Classifications eCl@ss eCl@ss 10.0.1 27440109 eCl@ss 5.1 27143423 eCl@ss 6.0 27279220 eCl@ss 8.0 27279218 eCl@ss 9.0 27440103 ETIM ETIM 4.0 EC001855 ETIM 5.0 EC001855 ETIM 6.0 EC002061 UNSPSC UNSPSC 13.2 39121413 UNSPSC 18.0 39121413 UNSPSC 19.0 39121413 UNSPSC 20.0 39121413 UNSPSC 21.0 39121413 Approvals Approvals Approvals EAC / cULus Recognized 05/16/2020   Page 3 / 4 https://www.phoenixcontact.com/us/products/1413178 Flush-type connector - SACC-DSI-M12MSB-5CON-M16/0,8 - 1413178 Approvals Ex Approvals Approval details EAC      B.01687 cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  E221474-20140616     Nominal voltage UN 60 V Nominal current IN 4A mm²/AWG/kcmil 22-20 Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 05/16/2020   Page 4 / 4
1413178 价格&库存

很抱歉,暂时无法提供与“1413178”相匹配的价格&库存,您可以联系我们找货

免费人工找货