FOC-M12-MNNA-TC...
M12 FO transceivers
Data sheet
103995_en_02
1
© PHOENIX CONTACT 2015-01-28
Description
The FO transceiver is available in two versions.
– FOC-M12-MNNA-TC-1300 for applications with
50/125 μm, 62.5/125 μm or 200/230 μm fibers
– FOC-M12-MNNA-TC-650 for applications with
980/1000 μm fibers
The FO transceiver features a high-speed transmitter and
receiver circuit with a 1310 nm or 650 nm optical wavelength at high optical power. This makes the M12 transceiver an ideal alternative in data transmission systems with
fiber optics.
An I2C interface ensures that the transceiver is efficiently
monitored and managed.
Due to the high data transmission rate of 125 Mbps, the optical characteristics, and connection technology for the fiber
optics, the M12 transceiver offers a wealth of application options:
– Optical networks
– Fast Ethernet
– Industrial electronics
– Power electronics
1.1
–
–
–
–
–
–
–
–
–
Properties
125 Mbps
+3.3 V power supply
PECL inputs/outputs
Signal Detect (SD) output
I2C management interface
Metal housing
Pin connector pattern in accordance with 61754-27
Ambient temperature: -40°C... +85 °C
RoHS-compliant
FOC-M12-MNNA-TC-1300
–
–
–
–
1310 nm wavelength
-19°dBm output power (50/125 μm)
-30 dBm receiver sensitivity
Suitable for 50/125 μm, 62.5/125 μm and 200/230 μm
FOC-M12-MNNA-TC-650
–
–
–
–
650 nm wavelength
-4 dBm output power (980/1000 μm)
-20 dBm receiver sensitivity
Suitable for 980/1000 μm
To optimize transmission performance and to achieve the maximum transmission path, correctly pre-assembled
fiber optic connectors are required.
Loads that exceed the specified limit values can cause permanent damage to the component. The limit values represent the load limits of the component.
Make sure you always use the latest documentation.
It can be downloaded at phoenixcontact.net/products.
This data sheet is valid for all products listed on the following page:
FOC-M12-MNNA-TC...
2
Ordering data
Fiber optic transceiver
Description
Order No.
Pcs. / Pkt.
M12 FO transceiver, duplex, wavelength: 650 nm for 125 Mbps, for POF and FOC-M12-MNNA-TC-650
PCF fibers, for PCB mounting, M16 fastening thread, with sealing cap, including I²C interface for transceiver monitoring and management
Type
1416716
1
M12 FO transceiver, duplex, wavelength: 1300 nm for 125 Mbps, for GOF fi- FOC-M12-MNNA-TC-1300
bers, for PCB mounting, M16 fastening thread, with sealing cap, including I²C
interface for transceiver monitoring and management
1416729
1
Accessories
Description
Type
Order No.
Pcs. / Pkt.
M12 fiber optic coupler, duplex, suitable for all fibers, with wall bracket, IP65
degree of protection
FOC-M12-BU/BU
1416677
1
Assembled FO cable, round cable, 980/1000 μm POF fibers, for in- 1 m
stallation inside buildings
2m
M12 FO to M12 FO
5m
FOC-PN-B-1000/M12-C/SCRJ/1
1408865
1
FOC-PN-B-1000/M12-C/SCRJ/2
1408864
1
FOC-PN-B-1000/M12-C/SCRJ/5
1416648
1
Assembled FO cable, round cable, 980/1000 μm POF fibers, for in- 1 m
stallation inside buildings
2m
M12 FO to SCRJ/IP20
5m
FOC-PN-B-1000/M12-C/M12-C/1
1408871
1
FOC-PN-B-1000/M12-C/M12-C/2
1408870
1
FOC-PN-B-1000/M12-C/M12-C/5
1416680
1
Assembled FO cable, round cable, 200/230 μm PCF-GI fibers, for
installation inside buildings
1m
FOC-HCS-GI-1005/M12-C/M12-C/1
1408873
1
2m
FOC-HCS-GI-1005/M12-C/M12-C/2
1408872
1
M12 FO to M12 FO
5m
FOC-HCS-GI-1005/M12-C/M12-C/5
1416693
1
Assembled FO cable, round cable, 200/230 μm PCF-GI fibers, for
installation inside buildings
1m
FOC-HCS-GI-1005/M12-C/SCRJ/1
1408867
1
2m
FOC-HCS-GI-1005/M12-C/SCRJ/2
1408866
1
M12 FO to SCRJ/IP20
5m
FOC-HCS-GI-1005/M12-C/SCRJ/5
1416651
1
Assembled FO cable, round cable, 50/125 μm GOF-MM fibers, for
installation inside buildings
1m
FOC-M12-M12-GB02/2
1408874
1
2m
FOC-M12-M12-GB02/1
1408875
1
M12 FO to M12 FO
5m
FOC-M12-M12-GB02/5
1416703
1
Assembled FO cable, round cable, 50/125 μm GOF-MM fibers, for
installation inside buildings
1m
FOC-M12-LC:A-GB02/1
1408869
1
2m
FOC-M12-LC:A-GB02/2
1408868
1
M12 FO to LC duplex
5m
FOC-M12-LC:A-GB02/5
1416664
1
3
Limit values
Loads that exceed the limit values can cause permanent
damage to the component. The limit values represent the
load limits of the component.
Continuous operation with these values is not recommended, as this may jeopardize the reliability of the component.
The FO transceiver, connectors, and couplings should only
be mounted finger tight.
Limit values
Operating temperature
-40 °C ... +85°C
Storage temperature
-40 °C ... +100°C
Soldering temperature 2 mm from housing, t 5 s
260°C
Supply voltage
4V
Data input voltage
-0.5 V ... 4 V
Differential input voltage
2 V (peak-to-peak with FOC-M12-MNNA-TC-1300)
PECL output current
-50 mA ... +50 mA
Electrostatic air discharge in acc. with EN 61000-6-2
8 kV
Electrostatic contact discharge in acc. with EN 61000-6-2
4 kV
Immunity of electrical field in accordance with EN 61000-6-2
10 V/m
2/8
PHOENIX CONTACT
103995_en_02
FOC-M12-MNNA-TC...
4
Technical data
General data
Storage temperature
-40 °C ... 100 °C
Ambient temperature
-40 °C ... 85 °C
Supply voltage
3 V ... 3.6 V, typical 3.3 V
Differential input voltage
1 V ... 1.8 V, typical 1.4 V
Current carrying capacity
50 Ω
Data rate
125 Mbps
Humidity
5 % ... 95 %
Transmitter
FOC-M12-MNNA-TC-650
FOC-M12-MNNA-TC-1300
Maximum wavelength λmax
625 nm ... 675 nm, typical 650 nm
1280 nm ... 1340 nm, typical 1310 nm
Average optical output voltage
-8 dBm ... -5 dBm
-21 dBm ... -18 dBm
980/1000 μm, 50 % DC, NA 0.5
50/125 μm, 50 % DC, NA 0.2
Current consumption
70 mA ... 80 mA
90 mA ... 120 mA
Rise time
2.5 ns
1.8 ns
1.8 ns
Fall time
2.5 ns
Data input current for logical “0”
at least -50 μA
at least -50 μA
Data input current for logical “1”
maximum +50 μA
maximum +50 μA
Data input voltage for logical “0”
-1.81 V ... -1.475 V
-1.81 V ... -1.475 V
Data input voltage for logical “1”
-1.165 V ... -0.88 V
-1.165 V ... -0.88 V
Receiver
FOC-M12-MNNA-TC-650
FOC-M12-MNNA-TC-1300
Maximum receiver sensitivity
-25 dBm
-31 dBm
Maximum input power
At least 2 dBm
at least -3 dBm
Current consumption
70 mA ... 80 mA
70 mA ... 80 mA (no load)
Threshold value for signal detection
-20 dBm
-29.2 dBm
Signal detection hysteresis
1.5 dB ... 6 dB, typical 3 dB
1.5 dB ... 5 dB, typical 2.5 dB
Maximum response time, signal detection
10 μs
10 μs
Maximum fall time, signal detection
10 μs
10 μs
Signal detection output voltage log. 0
-1.83 V ... -1.55 V
-1.83 V ... -1.55 V
Signal detection output voltage log. 1
-1.08 V ... -0.88 V
-1.08 V ... -0.88 V
Data output voltage log. 0
-1.83 V ... -1.55 V
-1.83 V ... -1.55 V
Data output voltage log. 1
-1.08 V ... -0.88 V
-1.08 V ... -0.88 V
Data output rise time 20 % ... 80 %
2.2 ns
2.2 ns
Data output fall time 80 % ... 20 %
2.2 ns
2.2 ns
Bit error rate