1417379

1417379

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MODULEFEMALE1POSSCREW

  • 数据手册
  • 价格&库存
1417379 数据手册
https://www.phoenixcontact.com/us/products/1417379 Contact insert module - HC-M-01-AT-F-40 - 1417379 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Contact insert module, Number of positions: 1, Socket, Axial screw connection, 1000 V, 200 A, 25 mm² ... 70 mm², Application: Power Key Commercial Data Packing unit 1 STK Minimum order quantity 2 STK GTIN GTIN 4055626112602 Weight per Piece (excluding packing) 60.000 g Custom tariff number 85366990 Country of origin Poland Technical data Dimensions Height 60 mm Width 34.2 mm Length 29.4 mm Electrical characteristics Note Required for housing HC-B6 to B48, (housing height min. 72 mm), housing HC-ADVANCE-B6 to B24, hinged retaining frame HC-M-MHR..., axial connection for 5 mm Allen wrench Rated voltage (III/3) 1000 V Rated current 200 A Rated surge voltage 8 kV 04/11/2017   Page 1 / 5 https://www.phoenixcontact.com/us/products/1417379 Contact insert module - HC-M-01-AT-F-40 - 1417379 Technical data Electrical characteristics Connection profile 1 Ambient conditions Ambient temperature (operation) -40 °C ... 125 °C Mechanical characteristics Conductor cross section 25 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) Connection cross section AWG 3 ... 00 Stripping length of the individual wire 16 mm Tightening torque 8 Nm (25 mm² ... 35 mm²) 9 Nm (50 mm²) 10 Nm (70 mm²) Wire diameter including insulation 12 mm (25 mm²) 16 mm (40 mm²) Hexagonal socket WAF 5 Insertion/withdrawal cycles ≥ 500 Minimum housing height 72 mm General Series HC-M-HS Color light gray Number of module slots 2 Connection method Axial screw connection Flammability rating according to UL 94 V0 Degree of pollution 3 Overvoltage category III Assembly instructions - Use only flexible conductors, - Connection of wires with 5 mm an Allen wrench, - Housing height h ≥ 72 mm, - Connectors may only be operated without load/voltage. Connection Note regarding axial connection technology: Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used. Use of cables with a geometric cross section very different from the cable's nominal cross section should be checked before use. The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use. Connection Before starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go in the contact chamber (until the insulation touches the contact). Hold wires in position and use socket wrench to tighten. The used wire end should be cut off before 04/11/2017   Page 2 / 5 https://www.phoenixcontact.com/us/products/1417379 Contact insert module - HC-M-01-AT-F-40 - 1417379 Technical data General connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. Material data Contact material Copper alloy Contact surface material Ag Contact carrier material PC Standards and Regulations Flammability rating according to UL 94 V0 Drawings Dimensional drawing 40,6 30,3 29,4 Schematic diagram Female insert Diagram Diagram 400 Operating current [A] Operating current [A] 400 350 300 2 250 200 150 1 100 1 = 50 mm 50 0 2 20 2 300 250 200 150 1 100 1 = 50 mm2 50 2 = 70 mm2 0 350 40 60 80 100 120 0 2 = 70 mm2 0 20 Ambient temperature [°C] Derating diagram (3 modules in HC-B 24 housing) 40 60 80 100 120 Ambient temperature [°C] Two modules in B24 housing 04/11/2017   Page 3 / 5 https://www.phoenixcontact.com/us/products/1417379 Contact insert module - HC-M-01-AT-F-40 - 1417379 Schematic diagram Axial connection Approvals Approvals Approvals EAC / CSA / UL Recognized Ex Approvals Approval details EAC      7500651.22.01.00246 CSA    http://www.csagroup.org/services/testingand-certification/certified-product-listing/  13631     mm²/AWG/kcmil 00 Nominal current IN 116 A Nominal voltage UN 600 V UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     mm²/AWG/kcmil 2 Nominal current IN 146 A Nominal voltage UN 600 V  E118976 04/11/2017   Page 4 / 5 https://www.phoenixcontact.com/us/products/1417379 Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 04/11/2017   Page 5 / 5
1417379 价格&库存

很抱歉,暂时无法提供与“1417379”相匹配的价格&库存,您可以联系我们找货

免费人工找货