1425006

1425006

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    HEAVYCON MALE INSERT, D7 SERIES,

  • 数据手册
  • 价格&库存
1425006 数据手册
https://www.phoenixcontact.com/us/products/1425006 Contact insert - HC-D07-I-CT-F-42V-METAL - 1425006 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) HEAVYCON male insert, D7 series, 7-pos., crimp connection, with IP65 sealing screw Why buy this product  Can be used in rail vehicles, satisfy DIN EN 45545-2 with requirement sets R22, R23, and R24 in hazard levels HL1, HL2, and HL3. Key Commercial Data Packing unit 1 STK Minimum order quantity 10 STK GTIN GTIN 4055626383354 Weight per Piece (excluding packing) 10.000 g Custom tariff number 85366990 Country of origin China Technical data General Note For HC-D7 housing, crimp contacts CK1,6-ED (crimp contacts not included in scope of supply) Connection method Crimp connection Degree of pollution 3 Overvoltage category III Number of positions 7+PE Insertion/withdrawal cycles ≥ 500 Size D7 04/11/2017   Page 1 / 4 https://www.phoenixcontact.com/us/products/1425006 Contact insert - HC-D07-I-CT-F-42V-METAL - 1425006 Technical data General Conductor cross section 0.14 mm² ... 2.5 mm² Connection cross section AWG 26 ... 14 Stripping length of the individual wire 8 mm (0.14 ... 1.5 mm²) 6 mm (2.5 mm²) Assembly instructions Connectors may be operated only when there is no load/voltage. Ambient conditions Ambient temperature (operation) -40 °C ... 125 °C (including heating up of contacts) Material data Seal material NBR Contact material Copper alloy Contact surface material Ag (alternatively Au) Contact carrier material PC Standards/regulations PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) Electrical characteristics Rated voltage (III/3) 42 V Rated surge voltage 4 kV Rated current 10 A Standards and Regulations Connection in acc. with standard IEC / EN Constructional and testing regulations DIN VDE 0627/86 DIN VDE 0110/02.79 DIN VDE 0110-1/04.97 IEC 60664-1, DIN IEC 60512 IEC 60352 Flammability rating according to UL 94 V0 Drawings 04/11/2017   Page 2 / 4 https://www.phoenixcontact.com/us/products/1425006 Contact insert - HC-D07-I-CT-F-42V-METAL - 1425006 7 6 5 4 1 Diagram Current strength [A] Schematic diagram 7 2 3 2 3 1 6 5 4 20 16 12 8 2 = 1,5 mm 2 = 1,0 mm 2 = 0,75 mm 4 Connector pin assignment connection side: Left pin; right socket 0 0 20 40 60 80 100 120 Ambient temperature [°C] Derating diagram: Series HC-D 7-I-CT.. Dimensional drawing 21 21 32 Female insert Approvals Approvals Approvals UL Recognized / CSA Ex Approvals Approval details UL Recognized   http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     mm²/AWG/kcmil 14 Nominal current IN 10 A  E118976 04/11/2017   Page 3 / 4 https://www.phoenixcontact.com/us/products/1425006 Contact insert - HC-D07-I-CT-F-42V-METAL - 1425006 Approvals     Nominal voltage UN 42 V CSA   http://www.csagroup.org/services/testingand-certification/certified-product-listing/     mm²/AWG/kcmil 14 Nominal current IN 10 A Nominal voltage UN 42 V  13631 Phoenix Contact 2017 © - all rights reserved http://www.phoenixcontact.com 04/11/2017   Page 4 / 4
1425006 价格&库存

很抱歉,暂时无法提供与“1425006”相匹配的价格&库存,您可以联系我们找货

免费人工找货