0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1520026

1520026

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CABLE 5POS

  • 数据手册
  • 价格&库存
1520026 数据手册
https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Fieldbus flush-type plug, INTERBUS/PROFIBUS, 5-pos., M12 SPEEDCON, B-coded, front/screw mounting with M16 thread, can be positioned, with 0.5 m TPE litz wire, 5x0.25 mm² Your advantages  Pre-assembled with litz wires for immediate use  Customer-specific assemblies and litz wire lengths available  Sealed on the litz wire side for optimum leak-tightness  All standard pin assignments and codings for signal, data, and power transmission with a uniform design-in design  For high transmission safety: shield connection to the housing with optional EMC nut  SPEEDCON fast locking system reduces cabling times Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356020114 Weight per Piece (excluding packing) 25.800 g Custom tariff number 85366990 Country of origin Germany Technical data Dimensions Length of cable 0.5 m Ambient conditions Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket) Degree of protection IP67 11/04/2019   Page 1 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Technical data General Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Rated current at 40°C 4A Rated voltage 60 V Rated surge voltage 1.5 kV Number of positions 5 Insulation resistance ≥ 100 MΩ Coding B - inverse Standards/regulations M12 connector IEC 61076-2-101 Status display No Overvoltage category II Degree of pollution 3 Connection method Individual wires Insertion/withdrawal cycles > 100 Torque 3 Nm ... 4 Nm (Installation-side) Mounting type Front mounting M16 x 1.5 With locking nut Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Ni/Au Contact carrier material PA 6.6 Material of grip body Zinc die-cast, nickel-plated Material, knurls Zinc die-cast, nickel-plated Sealing material NBR Cable Cable type TPE litz wire Conductor cross section 0.34 mm² AWG signal line 22 Conductor structure signal line 7x 0.25 mm Core diameter including insulation 1.2 mm ±0.07 mm Thickness, insulation 0.21 mm Wire colors Black, brown,blue, white, gray Material conductor insulation TPE Conductor material Tin-plated Cu litz wires Standards/specifications M12 connector IEC 61076-2-101 11/04/2019   Page 2 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Technical data Cable Insulation resistance ≥ 20 MΩ*km Conductor resistance ≤ 57.6 mΩ/m Nominal voltage, cable 300 V Test voltage, cable 2000 V AC Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation) -25 °C ... 85 °C (cable, flexible installation) Standards and Regulations Standard designation M12 connector Standards/regulations IEC 61076-2-101 Flammability rating according to UL 94 V0 CE safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. • The products are suitable for applications in plant, controller, and electrical device engineering. • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. • Assembled products may not be manipulated or improperly opened. • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). • When using the product in direct connection with third-party manufacturers, the user is responsible. • For operating voltages > 50 V AC, conductive connector housings must be grounded • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product • Only use tools recommended by Phoenix Contact 11/04/2019   Page 3 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Technical data Standards and Regulations • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products • Ensure that the protective or functional ground has been properly connected. • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Environmental Product Compliance Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Dimensional drawing M12 flush-type plug, can be positioned 11/04/2019   Page 4 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Dimensional drawing Housing cutout for M16 fastening thread, mounting panel with thread Circuit diagram Contact assignment of the M12 plug and the M12 socket 11/04/2019   Page 5 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Schematic diagram Pin assignment M12 male connector, 5-pos., B-coded, male side Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 4.0 27140800 eCl@ss 4.1 27140800 eCl@ss 5.0 27143400 eCl@ss 5.1 27143400 eCl@ss 6.0 27279200 eCl@ss 7.0 27440103 11/04/2019   Page 6 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Classifications eCl@ss eCl@ss 8.0 27440103 eCl@ss 9.0 27440102 ETIM ETIM 2.0 EC001297 ETIM 3.0 EC002061 ETIM 4.0 EC002061 ETIM 5.0 EC002061 ETIM 6.0 EC002061 UNSPSC UNSPSC 6.01 31251501 UNSPSC 7.0901 31251501 UNSPSC 11 31251501 UNSPSC 12.01 31251501 UNSPSC 13.2 39121413 Approvals Approvals Approvals EAC / cULus Recognized Ex Approvals Approval details EAC      B.01742 cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  E221474-20140616     Nominal voltage UN 60 V 11/04/2019   Page 7 / 9 https://www.phoenixcontact.com/us/products/1520026 Flush-type connector - SACC-EC-MSB-5CON-M16/0,5 SCO - 1520026 Approvals     Nominal current IN 4A mm²/AWG/kcmil 22-20 Accessories Accessories Protective cap Sealing cap - PROT-M12 FS - 1560251 M12 sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush-type plugs and I/O devices in the field     Sealing cap - PROT-M12 FS-M - 1430488 M12 metal sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush-type plugs and I/O devices in the field     Seal Flat gasket - SACC-M16-SEAL CLM - 1430394 M16 flat gasket, for rear mounting of M12 flush-type connectors with M16 fastening thread     Flat nut - SACC-E-MU-M16 - 1504097 Flat nut with M16 thread     11/04/2019   Page 8 / 9 https://www.phoenixcontact.com/us/products/1520026 Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 11/04/2019   Page 9 / 9
1520026 价格&库存

很抱歉,暂时无法提供与“1520026”相匹配的价格&库存,您可以联系我们找货

免费人工找货