https://www.phoenixcontact.com/us/products/1533770
Bus system cable - SAC-5P-M12MS/ 0,2-920/M12MS - 1533770
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
®
®
Bus system cable, CANopen , DeviceNet™, CANopen /DeviceNet™, 5-position, PUR halogen-free, Violet, RAL
4001, shielded, Plug straight M12, A-coded, on Plug straight M12, A-coded, Cable length: 0.2 m
Key commercial data
Packing unit
11
Minimum order quantity
100 1
Weight per Piece (excluding packing)
47.8 GRM
Custom tariff number
85444290
Country of origin
Poland
Technical data
Dimensions
Length of cable
0.2 m
Ambient conditions
Degree of protection
IP65
IP67
IP68
General
Rated current at 40°C
4A
Rated voltage
60 V
Number of positions
5
Contact resistance
≤ 5 mΩ
Insulation resistance
≥ 100 MΩ
Coding
A - standard
Signal type/category
CANopen
®
DeviceNet™
Status display
No
Surge voltage category
II
Pollution degree
3
Insertion/withdrawal cycles
≥ 100
08.11.2013 Page 1 / 4
https://www.phoenixcontact.com/us/products/1533770
Bus system cable - SAC-5P-M12MS/ 0,2-920/M12MS - 1533770
Technical data
Material
Inflammability class according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Cable
Cable type
CAN Bus/DeviceNet
Conductor cross section
0.2 mm² (signal line)
0.32 mm² (Power supply)
0.32 mm² (Drain wire)
AWG signal line
24
AWG power supply
22
Conductor structure signal line
19x 0.12 mm
Conductor structure, voltage supply
19x 0.15 mm
Core diameter including insulation
2.05 mm ±0.1 mm (signal line)
1.4 mm ±0.05 mm (Power supply)
Wire colors
Red-black, blue-white
Twisted pairs
2 cores to the pair
Type of pair shielding
Aluminum-lined polyester foil
Overall twist
2 pairs around a drain wire in the center to the core
Shielding
Tinned copper braided shield
Optical shield covering
70 %
External sheath, color
Violet, RAL 4001
External cable diameter
6.70 mm
Smallest bending radius, fixed installation
67 mm
Smallest bending radius, movable installation
67 mm
Number of bending cycles
5000000
Bending radius
67 mm
Traversing path
10 m
Traversing rate
3 m/s
Acceleration
7 m/s²
Outer sheath, material
PUR
Material conductor insulation
PE (Power supply)
Foamed PE (signal line)
Conductor material
Tin-plated Cu litz wires
08.11.2013 Page 2 / 4
https://www.phoenixcontact.com/us/products/1533770
Bus system cable - SAC-5P-M12MS/ 0,2-920/M12MS - 1533770
Technical data
Cable
Insulation resistance
≥ 5 GΩ*km (signal line)
≥ 100 MΩ*km (Power supply)
Conductor resistance
≤ 78.4 Ω/km (signal line)
≥ 51.6 Ω/km (Power supply)
Working capacitance
39.3 pF (Signal line, Core-Core)
78.7 pF (Signal line, Core-Shield)
Nominal voltage, cable
300 V (Power supply)
30 V (signal line)
Test voltage, cable
1500 V (signal line)
2000 V (Power supply)
Classifications
eCl@ss
eCl@ss 4.0
27060306
eCl@ss 4.1
27060306
eCl@ss 5.0
27061801
eCl@ss 5.1
27061801
eCl@ss 6.0
27061801
eCl@ss 7.0
27061801
eCl@ss 8.0
27061801
ETIM
ETIM 2.0
EC000830
ETIM 3.0
EC001855
ETIM 4.0
EC001855
ETIM 5.0
EC001855
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
31251501
Drawings
08.11.2013 Page 3 / 4
https://www.phoenixcontact.com/us/products/1533770
Bus system cable - SAC-5P-M12MS/ 0,2-920/M12MS - 1533770
Schematic diagram
4
Schematic diagram
3
4
5
1
3
5
2
1
2
Pin assignment M12 male connector, 5-pos., A-coded, male side
Pin assignment M12 male connector, 5-pos., A-coded, male side
Cable cross section
Dimensioned drawing
Ø12
M12
Ø14,8
47,3
CAN Bus/DeviceNet [920]
Plug, M12 x 1, straight, shielded
Dimensioned drawing
Ø12
M12
Ø14,8
47,3
Plug, M12 x 1, straight, shielded
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
08.11.2013 Page 4 / 4