https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system flush-type socket, PROFIBUS, 2-pos., M12, shielded, B-coded, rear/screw mounting with M16
thread, with 5 m bus cable, 2 x 0.25 mm²
Your advantages
Pre-assembled with cables in various standard lengths for immediate use
Customer-specific assemblies and cable lengths can be supplied
Sealed on the cable side for optimum tightness of seal
Cable designs for all common networks and fieldbuses
For high transmission safety: shield connection to the housing with optional EMC nut
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356026581
Weight per Piece (excluding packing)
367.000 g
Custom tariff number
85444290
Country of origin
Germany
Technical data
Dimensions
Length of cable
5m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 85 °C (Plug / socket)
11/08/2019 Page 1 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Technical data
Ambient conditions
Degree of protection
IP67 (When plugged in)
IP65 (When plugged in)
General
Note
The electrical and mechanical data specified assume that the connector
pair is correctly locked and mounted. If the connector is unlocked and if
there is a danger of contamination, the connector must be sealed using
a protective cap > IP54. Influences arising from litz wires, cables or PCB
assembly must also be taken into consideration.
Rated current at 40°C
4A
Rated voltage
60 V
Rated surge voltage
1.5 kV
Number of positions
2
Insulation resistance
≥ 100 MΩ
Coding
B - inverse
Standards/regulations
M12 connector IEC 61076-2-101
Status display
No
Overvoltage category
II
Degree of pollution
3
Test voltage
2500 V
Insertion/withdrawal cycles
> 100
Material
Flammability rating according to UL 94
V0
Contact material
CuZn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material, knurls
Nickel-plated brass
Sealing material
FKM
Standards and Regulations
Standard designation
M12 connector
Standards/regulations
IEC 61076-2-101
Flammability rating according to UL 94
V0
CE safety note
WARNING: The connectors may not be plugged in or disconnected under
load. Ignoring the warning or improper use may damage persons and/or
property.
• WARNING: Commission properly functioning products only. The products
must be regularly inspected for damage. Decommission defective products
immediately. Replace damaged products. Repairs are not possible.
11/08/2019 Page 2 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Technical data
Standards and Regulations
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• When operating the connectors in outdoor applications, they must be
separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the
standards listed (e.g. the ones listed in the product accessories online at
phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly
connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are
applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient
conditions, the surface of the connector can continue to warm up. In
this case, the user is responsible for posting warnings (e.g. DIN EN ISO
13732-1:2008-12).
Cable
Cable type
PROFIBUS
Cable type (abbreviation)
910
UL AWM style
21198 (80°C/300 V)
Signal type/category
PROFIBUS
Cable structure
1x2xAWG24/19
11/08/2019 Page 3 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Technical data
Cable
Conductor cross section
2x 0.25 mm² (Signal line)
AWG signal line
24
Conductor structure signal line
19x 0.13 mm
Core diameter including insulation
2.55 mm ±0.07 mm
Wire colors
Red, green
Overall twist
2 cores with 2 fillers to the core
Shielding
Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering
85 %
External sheath, color
violet RAL 4001
External cable diameter D
7.8 mm ±0.2 mm
Smallest bending radius, fixed installation
40 mm
Smallest bending radius, movable installation
65 mm
Number of bending cycles
4000000
Bending radius
65 mm
Traversing path
4.5 m
Traversing rate
3 m/s
Acceleration
3 m/s²
Cable weight
90 kg/km
Outer sheath, material
PUR
Material, filler
PP
Material conductor insulation
Foam-Skin PP
Conductor material
Tin-plated Cu litz wires
Insulation resistance
≥ 5 GΩ*km
Conductor resistance
≤ 78.6 Ω/km
Cable capacity
nom. 30 pF/m
Wave impedance
150 Ω ±10 % (3 MHz ... 20 MHz)
Attenuation
≤ 0.049 dB/m (at 16 MHz)
Nominal voltage, cable
30 V
Test voltage Core/Core
1500 V (50 Hz, 1 min.)
Test voltage Core/Shield
1500 V (50 Hz, 1 min.)
Flame resistance
UL 1581, Sec. 1060 (FT-1)
IEC 60332-1-2
Halogen-free
in accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Other resistance
Low adhesion
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
11/08/2019 Page 4 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Technical data
Cable
-30 °C ... 80 °C (cable, flexible installation)
≤ 70 °C (cable, drag chain applications)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
11/08/2019 Page 5 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Dimensional drawing
Housing cutout for M16 fastening thread, mounting panel with feed-through hole (alternatively with surface as protection against rotation)
11/08/2019 Page 6 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Dimensional drawing
M12 flush-type connector
11/08/2019 Page 7 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Circuit diagram
Contact assignment of the M12 socket
11/08/2019 Page 8 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Schematic diagram
Pin assignment M12 socket, 5-pos., B-coded, female side
11/08/2019 Page 9 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Cable cross section
PROFIBUS [910]
Classifications
eCl@ss
eCl@ss 10.0.1
27440102
eCl@ss 4.0
27140800
eCl@ss 4.1
27140800
eCl@ss 5.0
27143400
eCl@ss 5.1
27143400
11/08/2019 Page 10 / 11
https://www.phoenixcontact.com/us/products/1534410
Bus system flat-type plug - SACCBP-M12FSB-2CONM16/5,0-910 - 1534410
Classifications
eCl@ss
eCl@ss 6.0
27279200
eCl@ss 7.0
27440103
eCl@ss 8.0
27440103
eCl@ss 9.0
27440102
ETIM
ETIM 2.0
EC001297
ETIM 3.0
EC002061
ETIM 4.0
EC000830
ETIM 5.0
EC002061
ETIM 6.0
EC002061
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
39121413
Approvals
Approvals
Approvals
EAC
Ex Approvals
Approval details
EAC
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
B.00767
11/08/2019 Page 11 / 11