1534588

1534588

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CABLE 4POS M12 SOCKET-CABLE .5M

  • 数据手册
  • 价格&库存
1534588 数据手册
https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Bus system flush-type socket, Ethernet, 4-pos., M12, shielded, D-coded, rear/screw mounting with M16 thread, with 0.5 m bus cable, 2 x 2 x 0.14 mm² Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356026758 Weight per Piece (excluding packing) 55.000 g Custom tariff number 85444290 Country of origin Germany Technical data Dimensions Length of cable 0.5 m Ambient conditions Ambient temperature (operation) -25 °C ... 90 °C (Plug / socket) Degree of protection IP67 (When plugged in) IP65 (When plugged in) General Rated current at 40°C 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) Rated voltage 60 V 11/08/2019   Page 1 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Technical data General Number of positions 4 Insulation resistance ≥ 100 MΩ Coding D - data Status display No Overvoltage category II Degree of pollution 3 Test voltage 2500 V Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Ni/Au Contact carrier material PA 6.6 Material, knurls Nickel-plated brass Sealing material NBR Standards and Regulations Flammability rating according to UL 94 V0 CE safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. • The products are suitable for applications in plant, controller, and electrical device engineering. • When operating the connectors in outdoor applications, they must be separately protected against environmental influences. • Assembled products may not be manipulated or improperly opened. • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). • When using the product in direct connection with third-party manufacturers, the user is responsible. • For operating voltages > 50 V AC, conductive connector housings must be grounded 11/08/2019   Page 2 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Technical data Standards and Regulations • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. • Observe the corresponding technical data. You will find information: o On the product o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product • Only use tools recommended by Phoenix Contact • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products • Ensure that the protective or functional ground has been properly connected. • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Cable Cable type PUR ETHERNET 2x2 FLEX Cable type (abbreviation) 93E UL AWM style 20963 (80°C/30 V) Signal type/category Ethernet CAT5 (IEC 11801), 100 Mbps Cable structure 2x2xAWG26/7; SF/UTP Conductor cross section 2x 2x 0.14 mm² AWG signal line 26 Conductor structure signal line 7x 0.16 mm Core diameter including insulation 0.98 mm Wire colors white/orange-orange, white/green-green Twisted pairs 2 cores to the pair Overall twist Two pairs with two fillers to the core Shielding Aluminum-coated foil, tinned copper braided shield Optical shield covering 70 % External sheath, color water blue RAL 5021 Outer sheath thickness 1.2 mm External cable diameter D 6.4 mm ±0.2 mm Minimum bending radius, fixed installation 4xD Minimum bending radius, flexible installation 8xD 11/08/2019   Page 3 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Technical data Cable Tensile strength GRP ≤ 80 N Cable weight 42 kg/km Outer sheath, material PUR Material conductor insulation Foamed PE Conductor material Bare Cu litz wires Standards/specifications Electrical requirements EN 50288-2-2 Insulation resistance ≥ 500 MΩ*km Loop resistance ≤ 290.00 Ω/km Cable capacity approx. 45 nF/km (at 1 kHz) Wave impedance 100 Ω ±5 Ω (at 100 MHz) Near end crosstalk attenuation (NEXT) 65.3 dB (with 1 MHz) 56.3 dB (at 4 МHz) 50.3 dB (at 10 MHz) 47.2 dB (at 16 MHz) 45.8 dB (at 20 МHz) 42.9 dB (at 31.25 МHz) 38.4 dB (at 62.5 МHz) 35.3 dB (at 100 MHz) Power-summated near end crosstalk attenuation (PSNEXT) 62.3 dB (with 1 MHz) 53.3 dB (at 4 МHz) 47.3 dB (at 10 MHz) 44.2 dB (at 16 MHz) 42.8 dB (at 20 МHz) 39.9 dB (at 31.25 МHz) 35.4 dB (at 62.5 МHz) 32.3 dB (at 100 MHz) Attenuation 3.2 dB (with 1 MHz) 6 dB (at 4 МHz) 9.5 dB (at 10 MHz) 12.1 dB (at 16 MHz) 13.6 dB (at 20 МHz) 17.1 dB (at 31.25 МHz) 24.8 dB (at 62.5 МHz) 32 dB (at 100 MHz) Return loss (RL) 23 dB (at 4 МHz) 24.1 dB (at 8 МHz) 11/08/2019   Page 4 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Technical data Cable 25 dB (at 10 MHz) 25 dB (at 16 MHz) 25 dB (at 20 МHz) 23.6 dB (at 31.25 МHz) 21.5 dB (at 62.5 МHz) 20.1 dB (at 100 MHz) Signal runtime 5.3 ns/m Coupling resistance ≤ 100.00 mΩ/m (at 10 MHz) Nominal voltage, cable ≤ 100 V (Peak value, not for high-power applications) Test voltage Core/Core 700 V (50 Hz, 1 min.) Test voltage Core/Shield 700 V (50 Hz, 1 min.) Current carrying capacity of cable 2 A (according to DIN VDE 0891-1) Flame resistance according to IEC 60332-1-2 in acc. to UL VW1 Halogen-free according to IEC 60754-1 Resistance to oil according to EN 60811-2-1 Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation) -20 °C ... 80 °C (cable, flexible installation) Ambient temperature (installation) -20 °C ... 80 °C Ambient temperature (storage/transport) -20 °C ... 80 °C Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 11/08/2019   Page 5 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Dimensional drawing Housing cutout for M16 fastening thread, mounting panel with feed-through hole (alternatively with surface as protection against rotation) 11/08/2019   Page 6 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Dimensional drawing M12 flush-type connector 11/08/2019   Page 7 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Circuit diagram Contact assignment of the M12 socket 11/08/2019   Page 8 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Schematic diagram Pin assignment M12 socket, 4-pos., D-coded, female side 11/08/2019   Page 9 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Cable cross section PUR ETHERNET 2x2 FLEX [93E] Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 4.0 27140800 eCl@ss 4.1 27140800 eCl@ss 5.0 27143400 eCl@ss 5.1 27143400 11/08/2019   Page 10 / 11 https://www.phoenixcontact.com/us/products/1534588 Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588 Classifications eCl@ss eCl@ss 6.0 27279200 eCl@ss 7.0 27440103 eCl@ss 8.0 27440103 eCl@ss 9.0 27440102 ETIM ETIM 2.0 EC001297 ETIM 3.0 EC002061 ETIM 4.0 EC000830 ETIM 5.0 EC002061 ETIM 6.0 EC002061 UNSPSC UNSPSC 6.01 31251501 UNSPSC 7.0901 31251501 UNSPSC 11 31251501 UNSPSC 12.01 31251501 UNSPSC 13.2 39121413 Approvals Approvals Approvals EAC Ex Approvals Approval details EAC   Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com    B.00767 11/08/2019   Page 11 / 11
1534588 价格&库存

很抱歉,暂时无法提供与“1534588”相匹配的价格&库存,您可以联系我们找货

免费人工找货