https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system flush-type socket, Ethernet, 4-pos., M12, shielded, D-coded, rear/screw mounting with M16 thread,
with 0.5 m bus cable, 2 x 2 x 0.14 mm²
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356026758
Weight per Piece (excluding packing)
55.000 g
Custom tariff number
85444290
Country of origin
Germany
Technical data
Dimensions
Length of cable
0.5 m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 90 °C (Plug / socket)
Degree of protection
IP67 (When plugged in)
IP65 (When plugged in)
General
Rated current at 40°C
4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data
is to be observed)
Rated voltage
60 V
11/08/2019 Page 1 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Technical data
General
Number of positions
4
Insulation resistance
≥ 100 MΩ
Coding
D - data
Status display
No
Overvoltage category
II
Degree of pollution
3
Test voltage
2500 V
Material
Flammability rating according to UL 94
V0
Contact material
CuZn
Contact surface material
Ni/Au
Contact carrier material
PA 6.6
Material, knurls
Nickel-plated brass
Sealing material
NBR
Standards and Regulations
Flammability rating according to UL 94
V0
CE safety note
WARNING: The connectors may not be plugged in or disconnected under
load. Ignoring the warning or improper use may damage persons and/or
property.
• WARNING: Commission properly functioning products only. The products
must be regularly inspected for damage. Decommission defective products
immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate
the product. They must observe the following safety notes. The qualified
personnel must be familiar with the basics of electrical engineering. They
must be able to recognize and prevent danger. The relevant symbol on the
packaging indicates that only personnel familiar with electrical engineering
are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and
electrical device engineering.
• When operating the connectors in outdoor applications, they must be
separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the
standards listed (e.g. the ones listed in the product accessories online at
phoenixcontact.com/products).
• When using the product in direct connection with third-party
manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must
be grounded
11/08/2019 Page 2 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Technical data
Standards and Regulations
• Ensure that when laying the cable, the tensile load on the connectors
does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The
suitable accessories are available online in the accessory section of the
product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly
connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are
applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient
conditions, the surface of the connector can continue to warm up. In
this case, the user is responsible for posting warnings (e.g. DIN EN ISO
13732-1:2008-12).
Cable
Cable type
PUR ETHERNET 2x2 FLEX
Cable type (abbreviation)
93E
UL AWM style
20963 (80°C/30 V)
Signal type/category
Ethernet CAT5 (IEC 11801), 100 Mbps
Cable structure
2x2xAWG26/7; SF/UTP
Conductor cross section
2x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
0.98 mm
Wire colors
white/orange-orange, white/green-green
Twisted pairs
2 cores to the pair
Overall twist
Two pairs with two fillers to the core
Shielding
Aluminum-coated foil, tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
Outer sheath thickness
1.2 mm
External cable diameter D
6.4 mm ±0.2 mm
Minimum bending radius, fixed installation
4xD
Minimum bending radius, flexible installation
8xD
11/08/2019 Page 3 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Technical data
Cable
Tensile strength GRP
≤ 80 N
Cable weight
42 kg/km
Outer sheath, material
PUR
Material conductor insulation
Foamed PE
Conductor material
Bare Cu litz wires
Standards/specifications
Electrical requirements EN 50288-2-2
Insulation resistance
≥ 500 MΩ*km
Loop resistance
≤ 290.00 Ω/km
Cable capacity
approx. 45 nF/km (at 1 kHz)
Wave impedance
100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)
65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Attenuation
3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Return loss (RL)
23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
11/08/2019 Page 4 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Technical data
Cable
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Signal runtime
5.3 ns/m
Coupling resistance
≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable
≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Current carrying capacity of cable
2 A (according to DIN VDE 0891-1)
Flame resistance
according to IEC 60332-1-2
in acc. to UL VW1
Halogen-free
according to IEC 60754-1
Resistance to oil
according to EN 60811-2-1
Ambient temperature (operation)
-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (installation)
-20 °C ... 80 °C
Ambient temperature (storage/transport)
-20 °C ... 80 °C
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
11/08/2019 Page 5 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Dimensional drawing
Housing cutout for M16 fastening thread, mounting panel with feed-through hole (alternatively with surface as protection against rotation)
11/08/2019 Page 6 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Dimensional drawing
M12 flush-type connector
11/08/2019 Page 7 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Circuit diagram
Contact assignment of the M12 socket
11/08/2019 Page 8 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Schematic diagram
Pin assignment M12 socket, 4-pos., D-coded, female side
11/08/2019 Page 9 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Cable cross section
PUR ETHERNET 2x2 FLEX [93E]
Classifications
eCl@ss
eCl@ss 10.0.1
27440102
eCl@ss 4.0
27140800
eCl@ss 4.1
27140800
eCl@ss 5.0
27143400
eCl@ss 5.1
27143400
11/08/2019 Page 10 / 11
https://www.phoenixcontact.com/us/products/1534588
Bus system flat-type plug - SACCBP-M12FSD-4CONM16/0,5-931 - 1534588
Classifications
eCl@ss
eCl@ss 6.0
27279200
eCl@ss 7.0
27440103
eCl@ss 8.0
27440103
eCl@ss 9.0
27440102
ETIM
ETIM 2.0
EC001297
ETIM 3.0
EC002061
ETIM 4.0
EC000830
ETIM 5.0
EC002061
ETIM 6.0
EC002061
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
39121413
Approvals
Approvals
Approvals
EAC
Ex Approvals
Approval details
EAC
Phoenix Contact 2019 © - all rights reserved