Bus system cable, 8-position, PUR halogen-free, water blue RAL 5021, shielded, Plug straight M12, A-coded, on
Socket straight M12, A-coded, Cable length: 10 m
Key commercial data
Packing unit
11
Custom tariff number
85444290
Country of origin
Germany
Technical data
Dimensions
Length of cable
10 m
Ambient conditions
Ambient temperature (operation)
-25 °C ... 90 °C (Plug / socket)
Degree of protection
IP65
IP67
General
Rated current at 40°C
2A
Rated voltage
30 V
Number of positions
8
Contact resistance
≤ 5 mΩ
Insulation resistance
≥ 100 MΩ
Coding
A - standard
Status display
No
Surge voltage category
II
Pollution degree
3
Insertion/withdrawal cycles
≥ 100
11.11.2013 Page 1 / 4
https://www.phoenixcontact.com/us/products/1554034
Bus system cable - SAC-8P-M12MS/10,0-940/M12FS - 1554034
Technical data
Material
Inflammability class according to UL 94
HB
Contact material
CuZn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Sealing material
NBR
Cable
Cable type
Ethernet
Cable type (abbreviation)
94F
Cable structure
4x2xAWG26/7; S/FTP
Conductor cross section
4x 2x 0.14 mm²
AWG signal line
26
Conductor structure signal line
7x 0.16 mm
Core diameter including insulation
1.04 mm
Thickness, insulation
0.28 mm (signal line)
0.65 mm (Outer cable sheath)
Wire colors
white/blue-blue, white/orange-orange, white/green-green, white/brownbrown
Twisted pairs
2 cores to the pair
Type of pair shielding
Aluminum-lined polyester foil
Overall twist
4 pairs
Shielding
Tinned copper braided shield
Optical shield covering
70 %
External sheath, color
water blue RAL 5021
External cable diameter D
6.4 mm ± 0.2 mm
Smallest bending radius, fixed installation
25.6 mm
Smallest bending radius, movable installation
51.2 mm
Cable weight
43 kg/km
Outer sheath, material
PUR
Material conductor insulation
PE
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 500 MΩ*km (at 20 °C)
Conductor resistance
≤ 290 Ω/km (at 20 °C)
Transmission characteristics (category)
CAT6A
Wave impedance
100 Ω ± 5 Ω (At 100 MHz)
Signal runtime
5.3 ns/m
11.11.2013 Page 2 / 4
https://www.phoenixcontact.com/us/products/1554034
Bus system cable - SAC-8P-M12MS/10,0-940/M12FS - 1554034
Technical data
Cable
Shield attenuation
≥ 80 dB (at 30 ... 100 MHz)
Nominal voltage, cable
≤ 100 V (at 20 °C)
Test voltage Core/Core
700 V (50 Hz, 1 min.)
Test voltage Core/Shield
700 V (50 Hz, 1 min.)
Flame resistance
IEC 60332-1-2
Halogen-free
According to IEC 60754-1
Resistance to oil
in accordance with DIN EN 60811-2-1
Ambient temperature (operation)
-40 °C ... 70 °C (cable, fixed installation)
-10 °C ... 50 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0
27060306
eCl@ss 4.1
27060306
eCl@ss 5.0
27061801
eCl@ss 5.1
27061801
eCl@ss 6.0
27061801
eCl@ss 7.0
27061801
eCl@ss 8.0
27061801
ETIM
ETIM 3.0
EC001855
ETIM 4.0
EC001855
ETIM 5.0
EC001855
UNSPSC
UNSPSC 6.01
31251501
UNSPSC 7.0901
31251501
UNSPSC 11
31251501
UNSPSC 12.01
31251501
UNSPSC 13.2
31251501
Drawings
11.11.2013 Page 3 / 4
https://www.phoenixcontact.com/us/products/1554034
Bus system cable - SAC-8P-M12MS/10,0-940/M12FS - 1554034
Schematic diagram
Schematic diagram
5
5
4
8
3
2
6
6
7
7
4
8
1
1
3
2
Pin assignment M12 socket, 8-pos., A-coded, view female side
Pin assignment M12 plug, 8-pos., view plug side
Cable cross section
Dimensioned drawing
Ø12
M12
Ø14,8
47,3
Ethernet [94F]
Plug, M12 x 1, straight, shielded
Dimensioned drawing
Ø15
M12
Ø12
44,5
M12 x 1 socket, straight, shielded
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
11.11.2013 Page 4 / 4