Extract from the online
catalog
SAC-4P-MS/ 0,3-186/FS SCO
Order No.: 1555680
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1555680
Sensor/Actuator cable, 4-position, PUR, Black-gray RAL 7021,
Plug, straight M12-SPEEDCON, A-coded, on Socket, straight M12SPEEDCON, A-coded, Cable length: 0.3 m
Product notes
WEEE/RoHS-compliant since:
11/30/2006
Commercial data
GTIN (EAN)
4
046356
173681
Note
Made-to-order
sales group
D111
Pack
1 pcs.
Customs tariff
85444290
Catalog page information
Page 286 (PC-2009)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
General data
Rated current at 40°C
4A
Rated voltage
250 V
Number of positions
4
Volume resistance
≤ 5 mΩ
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 1 / 5
Feb 14, 2011
SAC-4P-MS/ 0,3-186/FS SCO Order No.: 1555680
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1555680
Insulation resistance
≥ 100 MΩ
Length of cable
0.3 m
Ambient temperature (operation)
-25 °C ... 90 °C (Male connector / female connector)
General characteristics
Coding
A - standard
Surge voltage category
II
Pollution degree
3
Degree of protection
IP65/IP68/IP69K
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, (nickel-plated)
Sealing material
NBR
Status display
No
Conductor data
Cable type
PUR POWER 0.75 mm² black
Cable type (abbreviation)
186
Cable abbreviation
LiY11Y
Conductor cross section
0.75 mm²
AWG signal line
18
Conductor structure signal line
42x 0.15 mm
Core diameter including insulation
1.75 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
≥ 0.76 mm (Outer cable sheath)
External cable diameter
5.90 mm
Wire colors
Brown, white, blue, black
External sheath, color
Black-gray RAL 7021
Insulation resistance
≥ 1 MΩ*km
Conductor resistance
max. 26 Ω/km
Nominal voltage, conductor
≤ 300 V
Test voltage, conductor
≥ 3000 V
Overall twist
4 wires, twisted
Outer sheath, material
PUR
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 2 / 5
Feb 14, 2011
SAC-4P-MS/ 0,3-186/FS SCO Order No.: 1555680
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1555680
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Cable weight
57 kg/km
Smallest bending radius, movable installation
59 mm
Number of bending cycles
2000000
Bending radius
59 mm
Traversing path
5m
Traversing rate
3 m/s
Acceleration
5 m/s²
Ambient temperature (operation)
-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
Flame resistance
in accordance with DIN UL-Style 20549
Certificates / Approvals
Certification
CUL Listed, UL Listed
Diagrams/Drawings
Dimensioned drawing
M12-SPEEDCON plug, straight
M12-SPEEDCON socket, straight
Circuit diagram
Contact assignment of the M12 plug and the M12 socket
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 3 / 5
Feb 14, 2011
SAC-4P-MS/ 0,3-186/FS SCO Order No.: 1555680
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1555680
Schematic diagram
Pin assignment M12 plug, 4-pos., Acoded, view plug side
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Pin assignment M12 socket, 4-pos., Acoded, view female side
Page 4 / 5
Feb 14, 2011
SAC-4P-MS/ 0,3-186/FS SCO Order No.: 1555680
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1555680
Address
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
© 2011 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 5 / 5
Feb 14, 2011