1557808

1557808

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CONN FMALE INSERT 8POS SOLDER

  • 数据手册
  • 价格&库存
1557808 数据手册
https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Sensor/actuator flush-type socket, 8-pos., with straight THR solder connection Your advantages  Reduced mounting costs thanks to two-piece device connector  Packaging available for automated pick and place assembly  All common pin assignments and codings available  Easy device integration thanks to mechanical port screw connections with threaded attachment, press-in contour or direct integration in the front plate  Additional gasket for the device when not plugged in Key Commercial Data Packing unit 60 pc Minimum order quantity 60 pc GTIN GTIN 4046356285308 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket) -40 °C ... 85 °C (without mechanical actuation) -25 °C ... 85 °C (Plug / socket) Degree of protection IP67 (correctly plugged in and locked) General Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. 12/22/2021   Page 1 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Technical data General Rated current at 40°C 2A Rated voltage 30 V Rated surge voltage 0.8 kV Number of positions 8 Insulation resistance ≥ 100 MΩ Coding A - standard Standards/regulations M12 connector IEC 61076-2-101 Status display No Overvoltage category II Degree of pollution 3 Connection method THR solder connection Insertion/withdrawal cycles > 100 Mounting type PCB mounting Type of packaging Tray Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Au Contact carrier material PPA Sealing material FKM / EPDM Cable Standards/specifications M12 connector IEC 61076-2-101 Standards and Regulations Standards/specifications M12 connector IEC 61076-2-101 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 12/22/2021   Page 2 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Schematic diagram Drilling diagram Ø5,5 49 ° Ø1 4,5 5 6x 66° Pin assignment M12 socket, 8-pos., A-coded, view female side 8,5 Ø1,4 Drilling diagram Dimensional drawing 2,5 1,5 Ø8,25 Ø0,8 17 M12 female connector contact carrier Dimensional drawing 5,2 20 28 6 155 22 230 THR tray packaging Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 11.0 27440102 eCl@ss 4.0 27140800 eCl@ss 4.1 27140800 eCl@ss 5.0 27143400 12/22/2021   Page 3 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Classifications eCl@ss eCl@ss 5.1 27143400 eCl@ss 6.0 27279200 eCl@ss 7.0 27440103 eCl@ss 9.0 27440102 ETIM ETIM 3.0 EC002061 ETIM 4.0 EC002062 ETIM 6.0 EC002061 ETIM 7.0 EC002635 UNSPSC UNSPSC 6.01 31251501 UNSPSC 7.0901 31251501 UNSPSC 11 31251501 UNSPSC 12.01 31251501 UNSPSC 13.2 39121413 UNSPSC 18.0 39121413 UNSPSC 19.0 39121413 UNSPSC 20.0 39121413 UNSPSC 21.0 39121413 Approvals Approvals Approvals EAC / UL Recognized Ex Approvals Approval details EAC      B.01687 12/22/2021   Page 4 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Approvals UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm     Nominal voltage UN 30 V Nominal current IN 2A mm²/AWG/kcmil 24  FILE E 118976 Accessories Accessories Contact insert Sample set - SACC-CIM12FS8PL180THRSHSAMPLE - 1413561 Sensor/actuator flush-type socket, 8-pos., with straight THR solder connection, only contact insert     Panel mounting base Housing screw connection - SACC-M12-SCO NUT - 1552243 M12 SPEEDCON housing screw connection for M12 female inserts, with O-ring, for all SPEEDCON-capable THR and wave soldering contact carriers     Housing screw connection - SACC-DSIV-M12-NUT - 1416144 Housing screw connection with M12 standard thread, with O-ring, for the two-piece straight M12 THR contact carrier and for the two-piece angled M12 contact carrier     Housing screw connection - SACC-M12-SCO NUT L 90 - 1432460 M12-SPEEDCON housing screw connection for M12 female inserts, with flat gasket, for all Speedcon-compatible THR and wave soldering contact carriers     12/22/2021   Page 5 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Accessories Housing screw connection - SACC-BP-F-M12/M15-6-THR - 1414004 Housing screw connection, Socket, M12, Rear mounting, M15 x 1, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Housing screw connection - SACC-BP-F-M12/M15-7-THR - 1414003 Housing screw connection, Socket, M12, Rear mounting, M15 x 1, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Housing screw connection - SACC-BP-F-M12/M15-6-THR SCO - 1414020 Housing screw connection, Socket, M12-SPEEDCON, Rear mounting, M15 x 1, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Housing screw connection - SACC-BP-F-M12/M15-7-THR SCO - 1414005 Housing screw connection, Socket, M12-SPEEDCON, Rear mounting, M15 x 1, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Housing screw connection - SACC-BP-F-M12/THR-1,0/1,8-9TIP - 1419630 M12 threaded sleeve with tolerance-compensating function, for straight, THR solderable M12 socket contact inserts. Suitable for 1.0 mm ... 1.8 mm thick front plates.     12/22/2021   Page 6 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Accessories Housing screw connection - SACC-BP-F-M12/THR-1,7/2,5-9TIP - 1419631 M12 threaded sleeve with tolerance-compensating function, for straight, THR solderable M12 socket contact inserts. Suitable for 1.7 mm ... 2.5 mm thick front plates.     Housing screw connection - SACC-BP-F-M12/THR-2,4/3,2-9TIP - 1419633 M12 threaded sleeve with tolerance-compensating function, for straight, THR solderable M12 socket contact inserts. Suitable for 2.4 mm ... 3.2 mm thick front plates.     Housing screw connection - SACC-BP-F-M12/THR-3,1/3,9-9TIP - 1419634 M12 threaded sleeve with tolerance-compensating function, for straight, THR solderable M12 socket contact inserts. Suitable for 3.1 mm ... 3.9 mm thick front plates.     Housing screw connection - SACC-M12 NUT PRESS - 1437889 Housing screw connection for two-piece M12 connectors for the reflow soldering process.     Housing screw connection - SACC-DSIV-M12-NUT-9 THR - 1417989 M12 female connector, front mounting THR with M14 screw fastening     12/22/2021   Page 7 / 9 https://www.phoenixcontact.com/pi/products/1557808 Flush-type connector - SACC-CI-M12FS-8CON-L180-THR - 1557808 Accessories Housing screw connection - SACC-BP-F-M12-THR PP - 1027662 Housing screw connection, Socket, M12-Push-Pull, Rear mounting, M16, THR- und Wellenlötkontakte, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Housing screw connection - SACC-FP-F-M12-THR PP - 1027678 Housing screw connection, Socket, M12-Push-Pull, Front mounting, M14 x 1, THR- und Wellenlötkontakte, The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.     Plug for cable screw gland Screw plug - PROT-M12 - 1680539 An M12 screw plug for the unoccupied M12 sockets of the sensor/actuator cable, boxes and flush-type connectors     Screw plug - PROT-M12 SH - 1503302 An M12 screw plug for the unoccupied M12 sockets of the shielded sensor/actuator cable, boxes and flush-type connectors     Screw plug - PROT-M12 FB - 1555538 M12 high-grade steel screw plug, for unoccupied M12 sockets of the sensor/actuator cables, boxes and flush-type connectors for the food industry     12/22/2021   Page 8 / 9 https://www.phoenixcontact.com/pi/products/1557808 Phoenix Contact 2021 © - all rights reserved http://www.phoenixcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany Tel. +49 5235 300 Fax +49 5235 3 41200 http://www.phoenixcontact.com 12/22/2021   Page 9 / 9
1557808 价格&库存

很抱歉,暂时无法提供与“1557808”相匹配的价格&库存,您可以联系我们找货

免费人工找货
1557808
  •  国内价格 香港价格
  • 1+84.862451+10.64602

库存:254